RF-13-2116Miami Shores Village Building Department / V 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: JOB ADDRESS: BUILDING NE 94th Street SEP 18 ZM3 FBC 20 Permit No. Master Permit No. I"r ) 2 ROOFING City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcew 11-3206-013-6180 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): Pablo or W. Femanda Bressan Phone#: (305) 443-9676 Address: 326 NE 94th Street City. Miami Shores State: FL Zip: 33138 Tenant/Lessee Name: WA Phonek Email: femanda a-tag-fitness.com CONTRACTOR: Company Name: Morton Roofing. Inc. Phone#: 954-783-5883 Address: 500 NW 12th Avenue City: Pompano Beach State: FL Zip: 33069 Qualifier Name: John B. Morton. III Phone* 954-214-6818 State Certification or Registration #: CCC011043 Certificate of Competency #: DESIGNER: Architect/Engineer. N/A Phone#: Value of Work for this Permit: $ 15,400.00 SquareAAnear Footage of Work: �. #/D 3 Type of Work: OAddition ❑Alteration UNew WRepair/Replace DDemolition I I • Submittal Fee $ Permit Fee $ , L C CCF $ CO/CC $ Scanning Fee $ Radon Fee $ �V DBPR $ .�� Bond $ Notary $ Training/Education Fee $ �� Technology Fee $ �t ` Doable Fee $ Structural Review $ TOTAL FEE NOW DUE $� dL . r - Bonding Company's Name (if applicable) _N/A $ontg Company's Address City • State Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature,' Owner or Agent Contractor The foregoing instrument was acknowledged before me this 17th The omg instrument was acknowledged before me thislM day ofSe ted tuber. 20 -13, by Femanda Bressan day ofSeptember .20 13,by John B. Morton. 111 who is personally known tome or who has produced FL DL who is personally known tome or who has produced NL6 As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission I_\77:x1'/ � It711 NOTARY PUBLIC: Sign: Print II S. Tull JILL S. TULLY My Commission F -Vires JILL S. TULLY MY COMMISSION #EE43885 �n MY COMMISSION #M4M WIRES: NOV 21, 2014 EXPIRES: NOV 21, 2014 gshraug 1st State Insurance Sanded through 1st State Insurcm �x�x�xx�xx�a<ea�ese�x�x�eer<e F��71 Plans Examiner Zoning Structural Review Clerk (Revised 3/12/2012)(Rcvised (Y7/10/W)(RevisW 06110f2M) Revised 3/15/09) s Now RMfs Aamofs • Rgdrs CCC -011,043 Reslderrtiiat • Ccnmerd9 -The Oldest State Roofing License in FL- cr Friday, September 20, 2013 Chief Building Official Building Dept 10050 Northeast 2nd Avenue Miami Shores, Florida 33138 Ph: 305-795-2207 RE: Straps at the Bressan Residence 326 NE 94th Street, Miami Shores FL 33138 Dear Sir. I recently received a price quotation from MJK Construction; they are the firm we use to handle all of our strap work. According Michael Kulikowski, the owner of MJK Construction, the total cost (including engineering) of installing the new straps around the perimeter of the Bressan home will far exceed 158A of the contract value. The cost of the reroofing that we are performing is $15,400.00. Fifteen percent of that number is $2,310.00 - well below what it would cost to redo the straps. Mr. Bressan would prefer not to spend the money to install the straps. My understanding, based on our conversation and my reading of the statute, is that he is not required to do so. Please feel free to contact me or Mr. Bressan if you have any questions. Sincerely, gV Jon Morton ID President-MortonR ling, Inc 9/413 JILL S. TU LY PAY COMMISSION #EE43885 EXPIRES: NOV 21, 2014 4:24R.- Banded through 1st State Insurance 500 NW 12'k Avenue Pompano Beacla, FL 33069 Ph: 954-783-5883 Fax: 954-783-5629 { Angi Toll Free: 800 -548 -ROOF (7663) P 9/17/13 Property Search - Report Property Information: Folio 11-3206-013-6180 Property Address 326 NE 94 ST Owner Name(s) PABLO BRESSAN i£W 2013 FERNANDA BRESSAN Mailing Address 326 NE 94 STREET MAM SHORES FL Exemption/ Taxable 33138 PrimaryZone 1100 SGL FAMILY - 2301-2500 $50,000/$382,022 SQ Use Code 0001 RESIDENTIAL -SINGLE $25,0004407,022 FAMILY Beds/Baths/Half 4/210 Floors 2 Living Units 1 Adj. Sq. Footage 2,238 Lot Size 9,525 SQ FT Year Built 1939 Full Legal Description 1534165342 ORBook-Page MIAM SHORES SEC 1 AMD PB 212010 10-70 27200-3275 LOT 9 & E1 /2 LOT 10 BLK 46 Sales qualified as a result of examination of the deed LOT SIZE 75.000 X 127 $590,000 OR 15546-2765 1291 4 COC 23043-3667 012005 1 Assessment Information: Current Previous Previous 2 Year 2013 2012 2011 Land Value $177,096 $136,929 $119,069 Building Value $348,642 $349,316 $349,246 Market Value $525,738 $486,245 $468,315 Assessed Value $432,022 $424,801 $404,710 Benefits Information: Current Previous Previous 2 Benefit Type 2013 2012 2011 PortabilityAssessment 711975 $0 $0 $63,605 1 Sales w hich are qualified Reduction Save Our Homes Assessment $93,716 $61,444 $0 Reduction Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 i,'ate: not all benefits are applicable to ali Taxable Values (ie Counts. School Board, City, Regional). Disclaimer: MIAMI -DARE COUNTY OFFICE OF THE PROPERTY APPRAISER PROPERTY SEARCH SUN MARY REPORT Carlos Lopez-Caetau Property Appraiser Aerial Photography 2012 Taxable Value Information: Current Previous Previous 2 Year 2013 2012 2011 Exemption/ Taxable Exemption/ Taxable Exemption/ Taxable County $50,000/$382,022 $50,000/$374,801 $50,000/$354,710 School Board $25,0004407,022 $25,000/$399,801 $25,000/$379,710 City $50,0001$382,022 $50,000/$374,801 $50,000/$354,710 Regional $50,000/$382,022 $50,0001$374,801 $50,000/$354,710 Sale information: Date Amount ORBook-Page Qualification Code 212010 $690,000 27200-3275 Sales qualified as a result of examination of the deed 1/2005 $590,000 23043-3667 Sales which are qualified $550,000 22718-3051 Sales which are qualified F12/1991 $0 15546-2765 Sales w hich are disquafified as a result of exarrination of the deed $0 13969-1973 Sales which are disqualified as a result of examination of the deed 711975 1 $65,000 00000-0000 1 Sales w hich are qualified The Office of the Property Appraiser and Miami -Dade County are continually editing and updating the tax roll and CHS data to reflect the latest property information and GIS positional accuracy. No warranties, expressed or implied, are provided for data and the positional or thematic accuracy of the data herein, its use, or its interpretation. Although this website is periodically updated, this information may not reflect the data currently on file at Miami -Dade County's systems of record The Property Appraiser and Miami -Dade County assumes no liability either for any errors, omissions, or inaccuracies in the information provided regardless of the cause of such or for any decision made, action taken, or action not taken by the user in reliance upon any information provided herein. See Miami -Dade County full disclaimer and User Agreement at g isweb.miarridade.go%6Property5earchlprintMap.htm 1/2 'Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 September 19, 2013 Permit No: RF 13-2116 Buildina Critiaue Review 1. PROVIDE ENGINEERS DETAIL AND RECOMMENDATIONS TO RETROFIT THE ROOF TO WALL CONNECTIONS AS REQUIRED UNDER FS. FOR ON SITE BUILT SINGLE FAMILY HOMES. Ismael Naranjo Building Official Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re -submittal drawings. a 0 qj i Florida Building Code Edition 2010 s High Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit No. Process No. Contractor's Name Morton Roofing, Inc .lob Address 326 N.E. 94th Street ROOF CATEGORY ® Low Slope ❑ Mechanically Fastened Tile ® Mortar/Adhesio t ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingle Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof ® Reroofing ❑ Recovering ❑ Repair ❑ Ma e c ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 157 2,306 11403 and 04 SECTION B (Roof Plan) Illustrate all levels and sections, roof drains, scuppers, overflow 10low drains. Include dimensions of sections and levels, clearly ns of elevated pressure zones and location of parapets. W3 12'. D", 466 F 10' 0" co 15' 0" 0 LU , 0° r 174 SF "�•-� y W O r• Z 524 SF '� . ^M Cr 1..�.. Q P, '... a Q O J m = vi fn y }•'� 653 SF 528 -SF. 31'(r 6 70 SF C � 15 0" 1 W3 W r & Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, identify as "NAJ System Manufacturer: GAF NOA No.: 07-1219.09 Design Wind Pressures, Fro RAS 128 r Calculations: Pmaxi : -42.8 Pmax2: -71.7 Pmax3: -108.0 Max. Design Pressure, From the Specific NOA System: -52.5 Deck: Type: Wood Gauge/Thickness: 5/8" or greater Slope: <1" Anchor/Base Sheet & No. of Ply(s): NIA Anchor/Base Sheet Fastener/Bonding Material: NIA Insulation Base Layer: NIA Base Insulation Size and Thickness: NIA Base Insulation Fastener/Bonding Material: NIA Top Insulation Layer: NIA Top Insulation Size and Thickness: NIA Top Insulation Fastener/Bonding Material: NIA Base Sheet(s) & No. of Ply(s): 1 Ply - GAFGIass 75# Base Sheet Fastener/Bonding Material: 1414" Ring Shank Nails and Tin Caps Ply Sheet(s) & No. of Ply(s): 2 Plies - GAF Ply IV Field:—6 " oc @ Lap, # Rows 2 @ 9 " oc Perimeter: 6 " oc @ Lap, # Rows 4 @ 6 " oc Corner: 6 " oc @ Lap, # Rows 4 @ 6 " oc Number of Fastenerp Per Insulation Board /� j tj Field: Perimeter j� Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Stucco over 3'x3" Gaiv 4x5 Galy I Eaves Drip L Flashing I=T12 Ply Sheet Fastener/Bonding Material: Hot Asphalt Top Ply: i Ply - GAF Glass Cap Mineral Surfaced Cap Top Ply Fastener/Bonding Material: Hot Asphalt Surfacing: Granuals Wood Mean Roof Height 1. Base sheet fastened with 14W RSN 2. 2 x ply IV set in hot asphalt 3. Mineral Surface Cap Sheet in hot asphalt 4.3"x3" Gaiv. Eaves Drip with 1414" RSN to of is more than' from neighbors Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Entegra Product Approval Number: 104202.01 Minimum Design Wind Pressures, If Applicable (From AS 127 r Calculations): Pi : -39.1 P2: -68.1 133: -100.7 Maximum Design Pressure Product Approval Specific System: 40A (Moments) Method of Tile Attachment: Polyfoam - NOA =12-0228.18 Steep Sloped System Description Deck Type: Roof Slope. 4 :12 Ridge Ventilation? NIA Wood Underlayment: 30# ASTM Mean Roof Height: 14' N/A Barrier: NIA Type & Spacing: 1 1/4" Galy Ring Shank Nails 16" on laps, 2 rows 12" O.C. iesive Type: Asphalt Type Cap Sheet: 90#, 3' SBS @i Eaves and Valleys SBS NOA -12-0406.07 Roof Covering: TILE Type & Size Drips Edge: 3"x3" White Galvanized Florida Building Code Edition 2010 f High Velocity Hurricane Zone Uniform Permit Application Form 9 Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for M,with the values from M,. If the M, values are greater than or equal to the M, values, for each area of the roof, then the the attachment method Is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P,:-39.1 x A .289 =11.30 1 -Mg: 7-67 = Mt1 3.63 Product Approval Mt 40A (p2; -68.1 XX .289 = 19.68 ) - Mg: 7.67 = M12 12.01 Product Approval M, 40A (pg: x .289 =29.10 t -M:7.67 g = Mr2 2'I.43 Product Approval Mf 40A Method 2 "Simplified 71le Calculation Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M Required Moment Resistance* Mean Roof Height --to. Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 1 27.1 28.2 1 30.0 'Must be used in conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based the systems use Method 3. Compare the values for F' with the values for F,. If the F' values are greater than or equal to the F, values, for each area of the roof, then the file attachment method Is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P,: x 1: = x W:= _I - W: x cos 0: - = F,1 Product Approval F (P,: x 1: = x W- _I - W: x cos 0: - = Fn Product Approval F' (P,: x 1: = x W:= _ ) - W: x cos 0: - = Fra Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based an ASCE 7 Mean Roof Height H Job Site Roof Slope a Job Site Aerodynamic Multiplier i, Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance M, Product Approval Required Moment Resistance K Calculated Minimum Attachment Resistance P Product Approval Required Uplift Resistance Fr Calculated Average life Weight W Product Approval Tile Dimensions I - length vv a vWdth Product Approval Ali calculations must be submitted to the &Ading Official at the time of permit application. 0 a Owner's Notification Form 07 MIAMI- [�[V LkMME "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the ite as been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane } are for the purpose of providing that the roofing system meets the wind resistance and water intrusion rformaace standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed a f the agreement between the owner and the contractor. Wed 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Buil' g Code. (The roof deck is usually concealed prior to removing the existing roof system). 93. Common roofs: Common roofs are those which have no visible delineation between neighboring (i.e. townhouses, condominiums, etc.)..In buildings with common roofs, the roofing contractor and/or own should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be ewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of main ' ' g this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may use water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original r g system is removed, Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not erloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of. Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 1 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the or of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate the attic venting, venting shall not be re ' ed. Owner's/Agent's Signature: Date: / 17 / 13 Contractor's Signature: Permit Number: Property Address: 3 E 94th Street, Miami Shores, FL 33138 M IA M I.M. fx BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE QWA) GAF Material Corporation. 1361 Alps Road Wayne, NJ 07470 MIAMI DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-290I FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review. Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL ofthis NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERAUNATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03-0501.05 and consists ofpages 1 thro gh 19. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 07-1219.09 i tau Expiration Date: 11/04/13 Approval Date: 03120/08 Page 1 of 19 0 ROOFING SYSTEM APPROVAL Catcgory: Roofing Sub&gftorv: BUR Deck Type: Wood Maximum Design Pressure -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product PM4uct Dimensions Specification Description Leak BusterTM Matrix7w 3, 5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote 307 Premium Asphalt adhesion of asphalt in built-up roofing. Primer GAF Mineral ShieldTm Granules Leak Bustefm MatrixTm 305 Fibered Asphalt Emulsion 60 & 100 lb. bags ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. 5 gallons ASTM 1227 Surface coating for smooth surfaced roofs. Leak Busteim MatrixTm 1, 5 gallons ASTM D 2824 Fibered aluminum coating. 303 Premium Fibered Aluminum Roof Coating LoakBusterTM MatrixTM 55 gallons Elastomeric roof coating. 322 Elastomeric Roof Coating LeakBusterTm MatrixTM 55 gallons Asphalt emulsion fibemd. Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 204 WebUy Roof Cement RUBEROID* Modified Bitumen Flashing Cement Le"usterTM Matrkm 201 Premium SBS Flashing Cement EGAFGLAS'* #75 APPROVED 1, 5 gallons ASTM D-4586 Refined asphalt blended with a mineral ASTM D-3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. 5 gallons ASTM D 4586 Fiber reinforced, polymer modified Flashing cement 5 gallons ASTM D 4586 Asphalt flashing Cement 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03120108 Page 2 of 19 Test Product Product Dimensions Specification Description GAFGLAS®#80 ULTIMATM Base Sheet GAFGLASo Flex Plym 6 (GAFGLAe Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAe EnergyCaplu Mineral Surfaced Cap Sheet GAFGLASO STRATAVENr EliminatorTm Perforated -GAFGLAS40 Flashing GAFGLAe STRATAVENr EliminatorTM Nailable RUBEROID® SBS Heat Weld`rm Smooth RUBEROIDo SBS Heat-WeldTM Granule RUBEROO SBS Heat WeldTM 170 FR RUBEROO SBS Heat WeldTm PLUS RUBEROI[? SBS Heat-WeldTm PLUS FR RUBEROID® SBS Meat WeldTM 25 39.37" (1 meter) ASTM D4601 Asphalt impregnated and coated, fiberglass wide base sheet 39.37" (1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt with wide asphalt coating. 39.3T'(1 meter) ASTM D 2178 Type IV asphalt impregnated glass felt with wide asphalt coating. 39.37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet wide surfaced with mineral granules. 39.37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet .wide surfaced with mineral granules with factory applied layer of TOPCOAT® EnergyCoteTM. 39.37" (I meter) ASTM D 4897 wide D 3672 Various 39.3T'(1 meter) ASTM D 4897 wide D 3672 1 meter (39.37") ASTM D-6164 wide 1 meter (39.3T') ASTM D-6164 wide I meter (39.37") ASTM D-6164 wide 1 meter (39.37") ASTM D-6164 wide 1 meter (39.37") ASTM D-6164 wide 1 meter (39.3T') ASTM D-6164 wide RUBEROID® Modified 39.37" (1 meter) ASTM D4601, Base Sheet wide Type II, UL Type G2 BUR GV.I,R APPROVED Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer -modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer -modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 3 of 19 Test Product Prodg Dimensions Speeifie tion Description RUBEROID" 20 RUBEROV Mop Granule RUBEROID® Mop Plus (Granule) RUBEROIDO MOP Smooth RUBEROID`s MOP 170FR RUBEROID0 MOP FR RUBEROMP TORCH Smooth RUBEROIDo TORCH Granule RUBEROIDP TORCH PLUS (Granule) RUBBROID® TORCH FR RUBEROIDP 170FR TORCH RUBEROIDP 30 RUBEROID® 30 FR RUBEROID® ULTRACLADO RUBEROO Dual FR Vent Stacks (metal and plastic) �P�aovEo � 39.37" (1 meter) ASTM D 6163 SBS modified asphalt base sheet and wide ASTM D 5147 interply sheat reinforce with a glass fiber 39.37" (1 meter) ASTM D 6222 wide ASTM D 5147 39.37" (1 meter) ASTM D 6222 wide ASTM D 5147 39.37" (1 meter) ASTM D 6164 wide ASTM D 5147 39.37" (1 meter) ASTM D 6164 wide ASTM D 5147 39.37" (1 meter) ASTM D 6164 wide ASTM D 5147 3937" (1 meter) wide 39.3T'(1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) Wide 39.3T'(1 meter) wide 39.37" (1 meter) wide 393T'(1 meter) wide 39.37" (1 meter) Wide ASTM D 5147 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 TAS 100(A) ASTM D 1929 ASTM D 635 mat. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer -modified asphalt and smooth surfaced. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granule's. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Asphalt impregnated, coated felt, surfaced with mineral granule. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Woven fiberglass mat coated with Polymer modified asphalt and surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer modified asphalt and surfaced with mineral granules. One way valve vent used to relieve built-up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 4 of 19 .. Cement Leak BusterTM MatrbOm 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 102 SBS Adhesive Adhesive. Leak Busteim Matrix7m 5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt 202 SB$ Flashing Adhesive — Flashing Grade. Cement Leak BusterTm Matrix7m 5 gallons ASTM D4586 Standard Plastic Asphalt Roofing Cement 203 Plastic Roof Cement' Leak BusterTM MatrWx m 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive NOA No.: 07-1219.09 Expiration Date: 11104/13 Approval Date: 03/20/08 Page 5 of 19 Test Product Product Dimensions SRecifieation Description Leak Bustofm MatrixTm 5 gallons ASTM D2824, Non-ftiered aluminum pigmented, asphalt 302 Non Fibered Type I roof coating. Aluminum Roof Coating GAF Built -Up Roofing 100 lb. cartons, ASTM D312, Interply mopping and surfacing asphalt. Asphalt bulk Types I, II, III and IV RUBEROID® MOD 60 lb. kegs SEBS modified asphalt. Asphalt, Asphalt L & Asphalt P Leak BusterTu MatrixTM 5 gallons Surface coating for smooth surfaced and 602 mineral surfaced roofs. Leak BusterTm MatrixTM 5 gallons Surface coating for smooth surfaced and 715 mineral surfaced roofs. LeakBusterm MatrixTM 2 gallons Surface coating for smooth surfaced and 531 WeatherCoteTM mineral surfaced roofs. SeamCot6rm 2, 5 gallons proprietary Elastomeric roofing membrane. . FireOutTm 5, 55 gallons Low VOC, fire barrier coating. VersaShiele 350 sq ft. roll Non -Asphaltic Fiberglass -Based Underlayment. VersaShicie FB_ is 350 sq ft. roll Non -Asphaltic Fiberglass -Based Underlayment. VersaShieldo FB -2S 350 sq ft. roll Non -Asphaltic Fiberglass -Based Underlayment. TOPCOAT FireShiele 5, 55 gallons ASTM D-412 Elastomeric roofing membrane MB ASTM D-21-96 ASTM D 1475 ASTM E-1644 Leak BusterTm MatrixTm 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 201 SBS Flashing Adhesive — Flashing Grade. Cement Leak BusterTM MatrbOm 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 102 SBS Adhesive Adhesive. Leak Busteim Matrix7m 5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt 202 SB$ Flashing Adhesive — Flashing Grade. Cement Leak BusterTm Matrix7m 5 gallons ASTM D4586 Standard Plastic Asphalt Roofing Cement 203 Plastic Roof Cement' Leak BusterTM MatrWx m 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive NOA No.: 07-1219.09 Expiration Date: 11104/13 Approval Date: 03/20/08 Page 5 of 19 •• Test Product Product Dimensions Specification Description . Leak BusterTM MatrixTM 5 gallons ASTM D 2824 Fibered aluminum coating. 303 Fibered Aluminum Roof Coating Leak BusterTM MatrixTM 5 gallons ASTM D2824, Non-fibered aluminum pigmented, asphalt 304 Non Fibered Type I roof.coating. Aluminum Roof Coating APPROVED INSULATIONS: Product Name EnergyGuardTM RA, RN Composite A & N EnergyGuardTm Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANTTM EnergyGuardTm Permalite Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Perlite EnergyGuardTM High Density Fiberboard EnergyGuardTM Composite EnergyGuardrm Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck', Dens Deck® Prime, Dens Deckoe Dura GuardTM Structodek SecurockTM ��PPROYED Table 2 Product Description. Polyisocyanumte foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Manufacturer (With Current NOA) BMCA GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. Tapered perlite board GAF Materials Corp. Perlite insulation board GAF Materials Corp. High density wood fiberboard insulation. GAF Materials Corp. Polyisocyanurate/wood fiberboard composite Polyisooyanurate/wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board 14175 sy1 generic generic generic G -P Gypsum Corp Knight Celotex 1JS0 Corporation NOA No.: 07-1219.09 Expiration Date: ll/NW Approval Date: 03/20/08 Page 6 of 19 N ,APPROVED FASTENERS: EVIDENCE SUBMITTED: Manufacturer Dimensions (With Current NOA) Various GAF Materials Corp. Various GAF Materials Corp. Various GAF Materials Corp. 3" and 3 '/2" GAF Materials Corp. 3" and 3 W' GAF Materials Corp. 3" Square GAF Materials Corp. Test Agency Teat Identifier TABLE 3 Fastener Product Product Number Name Description 1. Drill -Team #12 Standard, Insulation fastener and # 14 and # 15 extra Heavy. Base Play fastener for 07.09.99 Duty Fastener, Heavy steel, wood & concrete 4470 - TAS 114 Dirty Roofing Fastener decks. 2. Drill -Team ASAP Pre -assembled Drill - 3029832 Team Fasteners and 05.11.07 PRI Asphalt Technologies, Inc. metal and plastic plates. 3. Drill -Team #12 or #14 Base sheet fastening GAF -020-02-01 Standard screws with assembly. IRT of S. Fl. AccuTrac Plate TAS 114 4. Drill-Toa'A Galvalume Round Galvalume stress TAS 114 Plates plates. 5. Drill -Team Round polypropylene Polypropylene Plates stress plates. 6. Drill -Team AccuTrac Square GalvalumeP Plate coated steel plate. EVIDENCE SUBMITTED: Manufacturer Dimensions (With Current NOA) Various GAF Materials Corp. Various GAF Materials Corp. Various GAF Materials Corp. 3" and 3 '/2" GAF Materials Corp. 3" and 3 W' GAF Materials Corp. 3" Square GAF Materials Corp. Test Agency Teat Identifier Description Date Factory Mutual Research Corp. J.I.2B8A4.AM 4470 07.02.97 J.I.3139Q I AM 4470 01.08.98 J.I.ODOA8.AM 4470 07.09.99 d.I.ODiA8.AM 4470 - TAS 114 07.29:94 J.I.OY9Q5.AM 4470 - TAS 114 04.01.98 3029832 4470 - TAS * 114 05.11.07 PRI Asphalt Technologies, Inc. GAF -012-02-02 Physical Properties l 1.06.01 GAF -020-02-01 ASTM D 4977 02.01 A2 IRT of S. Fl. 02-005 TAS 114 01.18.02 02-014 TAS 114 03.22.02 APPK� NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 7 of 19 Deck Type 1: Wood, Non -insulated Deck Description: '9/32^ or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOutrm Fire Barrier Coating, VersaShieleNon-Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base sheet: GAFGLASO #80 ULTIMATM Base Sheet, STRATAVENTO EliminatorTm Nailable, RUBEROID® Modified Base Sheet, RUBEROI08 20, RUBEROID0 Heat WeIdTM Smooth or RUBEROID® Heat-WoldTM 25 base sheet mechanically fastened to deck as described below, Fastening Options:. GAFGLAS40 Ply 4, GAFGLAe Flex Plyrm 6, GAFGLAS1e #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring. shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLASO Ply 4, GAFGLAS`s.Flex P1yTM 6, GAFGLASO #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecT" #12 standard, #14 or # 15 Screws and 3" Drill-Te6m steel plate or Drill-To6m AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS@ Flex PlyTm 6, AFGLAS #75 ase Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field (Maximum Design Pressure S2.5 psf, See General Limitation #7) GAFGLAS* #SOULTIMATM, RUBEROTDO 20, RUBEROIDo Mop Smooth, base sheet attached to deck with approved 11/a" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure --60 psf, See General Limitatlon #7) GAFGLAS* #75 Base Sheet or any of above Base sheets attached to deck with Drill-TeeTm #12 standard, #14 or # 15 Screws and 3" Drill-TecTu steel plate or Drill -Teem AccuTrac Plates, l2" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and:3" inverted Drill TecTm insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure -60 psf, See General Limitation #7) NOA No.: 07-1219.09 Expiration Date: 11/04/13 DE Ouw Approval Date: 03/20/08 Page 17 of 19 GAFGLASO #75 Base Sheet or any of above Base sheets attached to deck with Drill TecTm #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTm AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (M, a dmam Design Pressure —75 psf, See General Lhraitution #7) Ply Sheet: One or ore plies of GAFGLASn PLY 4, #80 ULTIMA, RUBEROID® MOP Smooth or a ere in a II mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Cap Sheet: (Optional)One ply of GAFGLASv Mineral Surfaced Ca Sheet or GAFGLAS EnergyCaplm Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsJsq. and 300 IbsJsq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak Busterrm MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galJsq. 2. GAFGLAS'a Mineral Surfaced Cap Sheet, GAFGLAS`e Energy Cap Mineral Surfaced Capsheet adhered in a frill mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating,.at 1.5 galJsq. 4. Leak BusterTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT MB+, TOPCOATS' Fi reshield Elastomeric Roofing Membrane, applied at 1 to 1.5 galJsq. 5. Leak BusterTm Matriim 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote@ roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT' Surface Seal, TOPCOAT Fireshielde SB Solvent based Elastomeric Roofing Membrane applied at Ito -1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's ipecifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20%08 Page 18 of 19 WOOD DECK SYSTEM UwTATiow 1 A slip sheet is required with Ply 4 and Flex PlyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4" Dens DeckTM or t/a" Type X gypsum board is acceptable to be installed directly over the wood deck GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation maybe installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lb£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener.spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner area shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter natters, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07-1219.09 Expiration Date: 11/04!13 Ml� rE Cou Approval Date: 03/20/08 Page 19 of 19 G TGFU.R1306 Roofing Systems Page Bottom Roofing Systems See General Information for Roofino Systems GAF MATERIALS CORP 1361 ALPS RD WAYNE, NI 07470 USA R1306 "Ruberoid@ 20" or "Ruberoid@ 20 HT" or "Ruberoid@ Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1h -in. thick (minimum) gypsum board or 1/4 -in. thick (min) G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuand'" Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However, the butt joints in the gypsum board and G -P Gypsum Corp. "DensDeck @ Roofboard," "DensDeck Prime® Roofboard" or "DensDeck DuraGuardT" Roofboard" are to offset a minimum of b- in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Multiple plies of "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "Tri -Ply® Ply 6" may be adhered to G -P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard" in hot roofing asphalt. "EnergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification. "GAF Stratavent@ EllminatorT Venting Base Sheet (Nallable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover aver existing roof systems. "GAFGLAS@ Periite Insulation" may be utilized as a cover board over "EverGuard" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane Insulation adhesive. Polystyrene referenced in any of the following Classfications include "EnergyGuard EPS Insulation". References to glass fiber insulation include "EnergyGuard Fiberglass Insulation". ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or "Tri -Ply® #75 Base Sheet", or "GAFGLAS@ #80 ULTIMA") is a suitable alternate for Type GI asphalt glass fiber ply sheet ("GAFGLAS® Ply 4" or "Tri -Ply® Ply 4", or "GAFGLAS@ Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent@ Eliminator'" Venting Base Sheet (Perforated)" or "GAF Stratavent@ Eliminator*" Venting Base Sheet (Nailable)." Perforated to be loose laid or mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 ULTIMA" or "GAF Stratavent® Eliminator'" Venting Base Sheet (Nailable)" may be substituted for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS@ Ply 6") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. "GAFGLAS@ Flashing" or "Ruberoid@" may be used for flashing in any of the Class A, B or C systems listed below. When "perilte" is referenced, this includes "GAFTEMP PERMALTTE@" or any other UL Classified periite insulation. Crushed stone or slag are suitable alternates for gravel In any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck In the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of Vx-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum %-in. thick per ite board and deck with rosin paper (periite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuard RA" or "Tapered EnergyGuard RA" or "EnergyGuard Composite RA" may be substituted for any Atlas polyisocyanurate insulation in any of the following Classifications. TrumLejI "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". ;GAFGLAS@ #80 Premium Base Sheet" may be used in any of the following systems. ,"GAFGLAS@ Flex Ply 6" and "Tri -Ply® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLAS@ Ply 6". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise Indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "Fireshield MB" at 21h to 3- gal/100-ft2. "Ruberoid@ Dual Smooth" may be used as an alternate to "Ruberold@ Mop Smooth" or "Ruberold® 20" or "Ruberold® 20 HT" "Ruberoid® Mop Smooth 1.5" may be used as an alternate to "Ruberoid® Mop Smooth" Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid® Heat weld" SBS roofing membrane may be used in lieu of "Ruberoid® Mop" SBS products in any applicable Classification. Class A 1. Deck: C-15/32 Incline: 3 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type GI or "GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6" hot mopped. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type Gl or "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet " or "GAFGLAS® EnergyCap' T" BUR Mineral Surfaced Cap Sheet." 3. Deck: NC Incline: 2 Insulation (Optional): — One or more layers periite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, periite/urethane composite, wood fiber/polyisocyanurate composite, phenolic, 2 -In. maximum. Ply Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4", "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap" BUR Mineral Surfaced Cap Sheet." 4. Deck: C-15/32 Incline: i Glass Cap over Wood Slip Sheet (Optional): — Red rosin paper, nailed to deck. Insulation (optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" (may be nailed). Ply Sheet: — One or more plies Type GI "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or GAFGLAS@ Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap7" BUR Mineral Surfaced Cap Sheet." Surfacing (optional): — "TOPCOAT@ EnergyCote'"" applied at a rate of 2-gal/100-ft2. 5. Deck: NC Incline: 3 Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet". Ply Sheet: — One or more plies Type GI "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap7m BUR Mineral Surfaced Cap Sheet." 6. Deck: C-15/32 Incline: 2 Insulation: — One or more layers perlite, glass fiber, polyisocyanurate, urethane, periite/polyisocyanurate composite, perlite/urethane composite, phenolic, 1 In. minimum (offset a minimum of 6 -In. from plywood deck joints). Base Sheet: — One or more plies Type GI or Type G2 or Type G3. Membrane: — One or more plies "Ruberoid® Torch Smooth" or "Ruberoid® Torch Granule" or "Ruberoid® Torch Granule Plus" or "Ruberoid® Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid® Mop Granule" or "Ruberoid@ Mop Plus Granule" or "ROOFMatchTM SBS Modified Granular" or "Tri -Ply@ SBS Modified Bitumen Membrane" or "ROOFMatch' APP Modified Granular" or "Tri-Piy@ TP -4G" or "Tri -Ply@ TP -4" or "Ruberoid@ Dual Smooth". Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet"or "GAFGLAS@ EnergyCap"" BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt. 7. Deck: C-15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or rcou!lyl- MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 P (786) 31525-99 NOTICE OF ACCEPTANCE (NOA.) www.mlamidade.gov/vera TAMKO Building Products, Ina P.O. Box 1404 220 West 4s' Street Joplin, MO 64801 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tamko Underiayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TEIMMATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 08-1008.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Jorge L. Acebo. NOA Na: 12-0446.07 M� N r Expiration Date: 06/21/17 Approval Dale: Ob121/12 Page 1 of 6 ROOFING COMPONENT APPROVAL CaLe Roofing Sub-Catezorv: Underlayment Material: SBS SCOPE: This approves Tamko Underlayments, as described in this Notice of -Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPI,1(CANT: product TW Metal and Tile Underlayment Manufacturing Location #1 Moisture Guard Plus Manufacturing Location 91 TW Underlayment Manufacturing Location #2 Awafleg Manufacturing Location #1 Awaplan 17C Manufacturing Location #1 Test Product Dimensions Specification Dese ption 39 -Ys" wide TAS 103 Flexible, self -adhering rubberized asphalt ASTM D 1970 sheet material with a polymer surface for use as an underlayment in sloped roof assemblies. May be used as a secondary water barrier for full -roof coverage or, when out into appropriate width strips, for taping sheathing joints. 39-%" wide ASTM D 1970 Flexible, self -adhering rubberized asphalt sheet material with a granular surface for use as an underlayment in sloped roof assemblies. May be used as a secondary water barrier for full -roof coverage or, when out into appropriate width strips, for taping sheathing joints. 39-3A" wide ASTM D 1970 Flexible, self -adhering rubberized asphalt sheet material with a polymer surface for use as an underlayment in sloped roof assemblies. May be used as a secondary water barrier for full -roof coverage or, when out into appropriate width strips, for taping sheathing joints. 39-%" wide TAS 104 SBS modified cap sheet with a non- woven polyester mat saturated with asphalt, coated on both sides with SBS rubber modified p at and surfaced with ceramic granules. Applied in hot asphalt. 39 -Ye" wide TAS 104 A polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied in hot asphalt. NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 2 of 6 MANUFACTURING L4CATZON: 1. Joplia, MO 2. Columbus, KS ,�PPRG�'ED� NOA No.: 12-0446.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 3 of 6 Test Product Product Dimensions 3gecification Description Awaplan Premium''" 39 -Ye" wide TAS 104 A polyester reinforced SBS modified Manufacturing Location 0 bitumen membrane surfaced with granules. Applied in hot asphalt. Tamko SA Base 39 -Ye" wide ASTM D 1970 A fiberglass -reinforced self -adhering SBS Manufacturing Location #1 modified bitumen membrane with a polymer film on the surface and a removable treated split release film on the adhesive side. Shall only be meebanicaW fpstened to wood deck. Direct adhesion to wood deck not permitted in the FWM. Do Not Remove Release Film! Tamko SA Cap 39-3A" wide ASTM D 6164 A dual -coated SBS -modified cap sheet with Manufacturing Location #1 a nonwoven polyester mat surfaced with ceramic granules and a split removable release film on the adhesive side. EVIDENCE SUBAUTTED: Test Agency fiest Identifier Teat NameAeport Date ;Exterior Research & Design, LLC 4448.12.01-1 TAS 103 12/19/2001 4448.05.02-1 TAS 103 05/29/2002 Trinity 1 ERD T11090.09.08 TAS 117(B)/ TAS 114(C) 09/18/08 PRI Asphalt Technologies, Inc. TAP -058-02-01 TAS 103 04/30/02 TAP -058-02-02 TAS 103 05/23/02 TAP -191-02-01 ASTM D 1970 11/16/07 TAP -192-02-01 ASTM D 1970 11/13/07 TAP -193-02-01 ASTM D 1970 11/16!07 TAP -207-02-01 REV TAS 104/ ASTM D 4798 12/10/08 TAP -185-02-01 REV ASTM D 6164 11/06/08 TAP -196-02-01 ASTM D 1970 01/09/08 MANUFACTURING L4CATZON: 1. Joplia, MO 2. Columbus, KS ,�PPRG�'ED� NOA No.: 12-0446.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 3 of 6 APPROVED ASSEMBLIES: Deck Type 1: Wood, Non -insulated Deck Description: "/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a.minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of TW Metal and Tile Underlayment with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TW Metal and Tile Underlayment is acceptable. When used in Tile roof systems the capsheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Surfacing: Approved Mechanically Fastened Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type lI or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of Moisture Guard Plus with a minimum 3.5" side lap and 6" end lap. Place the first course of membrane parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with Moisture Guard Plus is acceptable. Surfacing: Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a 6" and lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of TW UndiaiTHyment with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TW Underlayment is acceptable. Surfacing: Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. NOA No.: 12-0406.07 f I C Expiration Date: 07/05/17 Approval Date: 01/12 Page 4 of 6 Deck Type 1: Wood, Non -insulated Deck Description: 19132" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type ll or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: waplan 170 or Awaplan Premium applied at a One or more plies �Upc right angle (90°) to ehe deck adhered in a Rill mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Vertical strapping of the roof with Awaflex, Awaplan 170 or Awaplan Premium underlayments is acceptable. When used in Tile roof systems the capsheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the and laps. No nails or tin caps shall be exposed. Surfacing: Approved Mechanically Fastened or Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an TAS 104 underlayment is allowed. Deck Type 1: Wood, Non -insulated Deck Description: 19132" or greater plywood or wood plank System E(6): Anchor sheet mechanically fastened to deck, membrane adhered. Base Sheet: One or more plies of Tamko SA Base with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Shall only be mechanically fastened to wood deck. Direct adhesion to wood deck not permitted in the HVH7. Do Not Remove Release Filml Membrane: One or mote plies of Tamko SA Cap with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact with base sheet. Remove the release liner as the membrane is applied. Vertical strapping of the roof with Tamko SA Cap underlayment is acceptable. When used in Tile roof systems the capsheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed Surfacing: Approved Mechanically Fastened Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D 6164 membrane is allowed. NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 5 of 6 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Tamko Underlayments shall be installed in strict compliance with applicable Building Codes. 3. All Tamko Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. Deck shall be fastened in strict compliance with applicable Building Codes. 4. All Tamko Underlayments shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 5. TW Metal and Tile Underlayment, Moisture Guard Plus, TW Underlayment, Tamko SA Base & Tamko SA CAP shall not be left exposed as a temporary roof for longer than 30 days of application. 6. Awaflex, Awaplan 170 and Aweplan Premium shall not be left exposed as a temporary roof for longer than 180 days of application. 7. The standard maximum roof pitch for Awaflex, Awaplan 170 and Awaplan Premium shall .be 6:12 for flat the installation and 6:12 profiled tiles with lugs. 8. The standard maximum roof pitch for TW Metal and Tile Underlayment and Tamko SA CAP shall be 4:12 for flat tile installation and 4:12 profiled tiles with lugs. 9. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 10. Tile storage shall be on a battened roof deck when the underlayment slope limit (See #7 & #8 above) is exceeded. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. 11. The Tamko Underlayments may be used with any approved roof covering Notice of Acceptance listing the Tamko Underlayment as a component part of an assembly in the Notice of Acceptance. If Tamko Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 12. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 13. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 14. For the self adhered membranes roll or broom the entire membrane surface so as to have 100% contact with the base sheet, giving special attention to overlap areas. 15. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 16. All protrusions or -drains shall be initially taped with a 6" piece of approved Tamko Underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit A second layer of the same Tamko Underlayment shall be applied over the taped underlayment. 17. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. n END OF THIS ACCEPTANCE NOA Noa 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 6 of 6 i i n — --- ' MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD .AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) ®1 N" IV.1nia lllidade. JVera 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the perfbrmance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 ROUFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof file adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2 -Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH - 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack© 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Prove Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.61bs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Fe 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Aaencv Test Identifier Test Name/Renort Date Center for Applied Engineering #94-060 TAS 101 04/08/94 01/16/95 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 roof file adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their file assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F —W 2 F'= MS NOA No.: 12-0228.18 Expiration Date: 05/10/17 M�,Mt'o�4be CCturnY Approval Date: 05/10/12 • D PP Page 3 of 7 INSTALLATION: 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof file assembly having a current NOA that lists uplift resistance values with the use of 3XITM 2 -Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet, 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1. 15 (A): 1.0 (B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile 2 Piece Barrel #1 17/side on cap and 34/ an N/A Flat, Low, Ifigh Profiles #2 24 NIA Flat Low, High Profiles #3 1 8 NOA No.: 12-0228.18 MIAMI DADE CQUwWry Expiration Date: 05/10/17 ®� Approval Date: 05/10/12 Page 4 of 7 LABELING: All 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY 1) Place en*ugh adhe" to aftva 17 to 23 OPWW 2K4?9 for squam hdo In Wided With the pan Nb SID01313fthapIskom Clailthroughplastkcement 2) Tunto": P8*r1W8"i* hL To i In. Fran outside Then usm dw die. Undfftayment t*Pwft SIVAIng dtheemma caumeavarft Abetteacandlemnot pan tft Emn emm eyW Pam" MOM paniowcomftnm Watemeft Emdaumn wet Faadg NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 1APPROVED1 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement Paddy (Bamth Th) Nail through plastic cement Paddy 0math Tile) Undedaymant untieflayms"t 7 In. 2 Im 7 hL% 2 In. Ems Comum Fascia Fascia % WwPhde Em Cam Em closure L- UP adp NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 Nall through plafic cement a WgIpaddy 3 X 3 Ini nunder the . Single Paddy on 2 In 4 In. undeI6 laymant on top of APPROVED ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY P8* Nail through plastic (between 99) Undertayment Paddy (under Ole) Nag through plastic _nt 31n.x3in. 41n. -I single P8* END OF THIS ACCEPTANCE Single paddy under the Single paddy between tie 2 In. x 7 In. medlum she pa" eave course only --1 Fade 11 Mephle ave closure Odp edge NOA No.: 12-0228.19 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 04,11A .11 n x 3 In paddyon under- layment ��� Single Em com Nag through plastic _nt 31n.x3in. 41n. -I single P8* END OF THIS ACCEPTANCE Single paddy under the Single paddy between tie 2 In. x 7 In. medlum she pa" eave course only --1 Fade 11 Mephle ave closure Odp edge NOA No.: 12-0228.19 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 .141AMIMDE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Roof Tile, Inc. 1289 NE 9'"' Ave Okeechobee, FL. 34972 MIAMI-DADE COUNTY, FLORIDA MBTRO DADE FLAGLF,R BUILDING 140 WEST FLAGLEX STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer`s name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein RENEWAL of this NOA shall be considerer) after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA No. 10-0804.15 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.: 10-1202.01 Expiration Date: 12/08/15 MlAMaQADECouNYY Approval Date: 12/30/10 Page 1 of 5 ., %- ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This renews a roofing system using Entegra "Plantation" concrete roof tile, as manufactured for Entegra Roof Tile, Inc. in Okeechobee, FL as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Test Product A.onlicant Dimensions Soecif'fi cations Description Plantation Tile Length: 16'x" Flat concrete roof tile for direct deck or Width: 13" TAS 112 batten nail -on. Trim Pieces Length: varies Accessory trim, concrete roof pieces for Width: varies TAS 112 use at hips, rakes ridges and valley Thickness: varies terminations 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION: 4.1 Entegra Roof Tile, Inc.'s Plantation Flat Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,119, & 120 4.2 Data For Attachment Calculations NOA No.: 10-1202.01 Expiration Date: 12/08/15 MAMFDADE COu Approval Date: 12/30/10 �. Page 2 of 5 Table 1: Average Weight (W) and Dimensions (I x w) ' Tile Profile Weight W (Ibf) Length -1 (ft) Width -w (ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multi liers - ft3 Tile X (ft3) % (ft3) Profile Batten Application Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M (ft Ibf) Tile 211: 12" 3": 12" 4":12" 6": 12" 6": 12" Greater than Profile 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7": 12" 9.8 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 51.7 24.4 Deck 24.3 Deck Deck 1-10d Smooth or Screw Shank Nail Eave Clip) Deck 19.0 Deck 2-10d Smooth or Screw Shank Nails Field Clip) Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-lbf) For Nail -On Systems Tile Profile .Fastener Type Direct Deck (Min 15/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Plantation Tile 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 48.3 1 Instailation with a C file headlap and fasteners are located a minimum of 2'/a from the head of Me. NOA No.:10-1242.01 Expiration Date: 12/08/15 Mia® Approval Date: 12/30/10 Page 3 of 5 . Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Pa Adhesive Set Systems ThProfile Tile Application Minimum Attachmente Pol ProTm 40.4 4 Lara® paddy placement of 45 arams of Resistance Plantation Tile Adhesive 31.3 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TlleBond Average weights per patty 13.9 grams. Pol Darn Product, Inc. Average weight pera 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Sin Is Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Pol Pro7m 118.9 Pol ProTm 40.4 4 Lara® paddy placement of 45 arams of Poi ProTm. 5 Medium paddy placement of 24 grams of Pol Pro's. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Stet S atems Tile Profile Tile Application Attachment Resistance Seespecific mortar manufacturer's Notice of Acceptance. 5. LABELING 5.1 All tiles shall bear .the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". 5.2 Entegra Roof Tile, Inc.'s Plantation Roof Tile bears the following markings: USA "E" USA, "E", Entegra "E", where the E is a stylized logo. 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. 7. MANUFACTURING LOCATIONS 7.1 Okeechobee, FL NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 4 of 5 � My PROFILE DRAWING PLANTATION FLAT CQNCRETE TILE END OF THIS ACCEPTANCE NOA No.: 10-1202.01 u�r Expiration Date: 12/08/15 Approval Date: ® Page 5 of 5 RE: Permit # RF -9-13-2116 Ae— Miami Shores Village Building Department INSPECTION AFFIDAVIT 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: 9-30-13 John B. Morton, ill licensed as a (n) Contractor Engineer / Architect, (Print name and drde License Type) FS 468 Building Inspector License t CCC011043 On or about 9-30-13 (j10 AM , I did personally inspect the roof deck nailing and (Date & time) work at 326 NE 94th Street, Miami Shores, FL 33138 (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F -S) Signature State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property mentioned. Swom to and subscribed before me this 30th day ofSeptember, 2013 JILL S. TULLY Notary Public, Sate of Florida at Large ®4� WCOMMISSION #EE4 EXPIRES: NOV 21, 2014 Bonded through 1st State InsuranCe *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each Inspection Revised on 5121009 November 15, 2013 Morton Roofing, Inc. 500 N.W. 12th Avenue Pompano Beach, Florida 33069 RE: TAS -106 TILE UPLIFT TESTS Proposed Roof Bressan Residence 326 N.E. 94" Street Miami Shores, Florida Dear Sir or Madam: ENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax: (866) 781-8550 www.floridaenginecringandtesting.com 250 S.W.13'h Avenue Pompano Beach, FL 33069 Job Order No.: 13-3369 Permit No.: RF -9-13-2116 `IZ'J'� In accordance with your authorization, Florida Engineering & Testing Inc., has performed Tile Uplift Testing in compliance with Testing Application Standards TAS -106 and the Florida Building Code High Velocity Hurricane Zone on November 14, 2013, at the above referenced project. The purpose of our inspection was to determine the uplift capacity of the roof tiles for the residence at the above referenced project. The subject roof consisted of concrete flat tile foam set. The pitch of the subject roof is 4/12. Our field engineer's representative visited the site and conducted sixty-two (62) uplift tests on the roof tiles. All tests were performed according to the Florida Building Code High Velocity Hurricane Zone and protocol TAS -106 using an Intercomp scale model CS200. The following is a summary of results: Field Test Results Test Number Test Location Field Uplift Pull Test Test Result 1 - 20 Corner See Attached Diagram 35 ± 5 pounds Passed 21 - 42 Perimeter See Attached Diagram 35 ± 5 pounds Passed 43 - 54 Field See Attached Diagram 35 f 5 pounds Passed 55 - 62 Ridge & Hip See Attached Diagram 35 f 5 pounds Passed r v Quakty �- � �'/asswrance Page 2 November 15, 2013 Job Order No. 13-3369 Morton Roofing, Inc. Bressan Residence 326 N.E. 94' Street Miami Shores, Florida: All test results were found to be in compliance with TAS -106 and the Florida Building Code (see attached field sketch). The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our attention for remedial work. This uplift test is not a final roof inspection. A final roof inspection must be conducted by the building official for approval. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. Florida Engineering & Testing, Inc. (FE&T) is an independent third parry providing un- biased testing information and results. FE&T is not affiliated with our client nor do we have any financial interest in the project or determination of the test results. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Florida Engineering & Testing, Inc., appreciates the opportunity to be of service to you at this phase of your project. If you have any questions or comments, please give us a call. We would be pleased to help in any way we can. It has been a pleasure working with you and look forward to doing so again in the near future. Sincerely, )/ 71/ /- -- �7 Reza Javidan, .E. Florida Engineering & Testing, Inc. Florida Reg. No. 60223 Certificate of Authorization No. 6923 .3o Field Sketch-Not to Scale Approximate Dimensions a=o.lw=o.1 x 30=3' 326 N.E. 94th Street a=0.4H=0.4 z 15=6' Perimeter Dimensions=3' Miami Shores, Florida