Loading...
RC-13-1919 (3)JUN 8 0 2014 i \jo rc e Rck��Y�P?Miami Shores village Building Department .� 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CERTIFICATE OF OCCUPANCY/COMPLETION CHECK LIST ❑ Building permit card. ❑ Surveys (2 copies) Final as built - Required Items: Elevations of buildings showing all intended setbacks from property lines and other existing structures. Ingress+ Egress, required parking spaces, Wheel stops, stripping, and all paving to exterior. ❑ Certificate of Elevation — (Sealed by surveyor). Expiration date required on the form. ❑ Certificate of Insulation. ❑ Certificate of Soil Treatment (Final treatment -original)\ CHAPTER 2913-5 TERMITE PROTECTION: "This Building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with the rules and law as established by the Florida Department of Agriculture and Consumer Services." ❑ Health Department Approval Letter (On septic or private water). Note: If the house is on septic tank, approval letter is required from Health Dpt. ❑ Soil Compaction Letter (Density report is required) ❑ Final certification letter from the Engineer/Architect (on masonry, trusses, special structure, etc) ❑ Backflow preventor certificate (Required on commercial projects only) ❑ Certificate of use. (Recorded in Miami -Dade Clerk of Courts) PLEASE NOTE THAT THE SAME ITEMS ARE REQUIRED FOR TEMPORARY CO • Emergency CO (Without 24 Hrs Processing) Additional fee is $80.00. • Temporary CO (Up to 90 days max) $75.00. • Residential CO fee is $150.00 • Commercial CO is $200.00 oMiami-Dade County Building Department 11805 S.W. 26 Street, Miami, FL 33175-2474 www.miamidade.gov/'ouildinp ENERGY. SOUND AND DIPACT CERTIFICATE Building Permit No: RL 39Tq Project Name: �� c- r - Job Address: AL 1—! S a M ul t.Y 1 w1�-�I�[ We, the undersigned, hereby rectify that the ANERGY. SOUND AND IMPACT INSULATION has been installed in the above referenced project, in compliancewith the latest edition of the FLORIDA MMMIA10 CODE. the DROVED ENERGY CAL U ,ATIONS and Plans and in accordance with good construction practice. The insulation famished and installed has the characteristics shown below: (check only applicable boxes). ❑ 1) Exterior CBS Walls Insulation: R _Ja, ]_ (Min.): Material: r rD a Thickness: inch NO Derl�rty ib/ih Mf r: ❑ 2) Exterior Frame/Metal Stud Walls: R (Min.): Material: _ Thicknem- inch (es): Density: Ib!$: Mfgr. ❑ 3) Exterior solid concrete walls: R- (Min.): Material: Thickness: inch Us): Density: Ib/R Mfgr. ❑ 4) Interior walls separating A/C from non A/C spaces insulation: R (Min.) Material• : Tbick[tow. inch (es); Density: 113/tt ❑ 5) MULT 6FAMMY RESIDENTIAL CONSTRUCTION ONLY: The COMMON ft1W walls to two separate conditioned tenancies shall be insulated to a mWnmm of R 11 for forme walls, and to R-3 on both sides of common masonry walls See ENERGY CODE, 2007, paragraph 13-602. A13C.1.1, on page 13.74, latest edition. These "m+++mmm lev -la of insulation", are not included in the Energy Calculations, but shall be installed in the field ❑ 6) Ceiling insulation R _5_CZ (Mm ); Materiat: b I Ow n Thickness- inch (es): Density: lb/it Mfg: ❑ 7) Walls, partitions and floor/ceiling assemblies between dwelling units or between dwelling units and adjacent public or service area such as halls, conidm% stains, etc. mast have a sound transmission class (STC) of not less than 50 (penetrations mut maintain the required rating). ❑ 8) Floor/ceiling assemblies between dwelling units or between dwelling units and public or service areas such as halls, corridors, stems, etc. must have an impact Imudation class (HQ rating of not less thea 50. Make photocopies of this sheet in your office, as required for friars jobs. Installed by: SOy rc-e Qernb � eI l n% Insulation company Name Insulation contractor CC# C 0 C I SJ O.C.Buiklee q oL me e 9 em p rel , n� Com�ny Name Building Contractor M: C3 -C Note: For llgbtweight Insulating concrete, me appropriate forms, separate from this one. Revised 02 -26 -nM A A260 ' °8 June 26, 2014 Miami Shores Village Building Department 10050 NE 2nd Avenue Miami Shores, Florida 33138 Permit Number: Address: Folio Number: Building Department, RC 13-1919 101 NE 105th Street 11-2136-005-0090 I, Victor J. Bruce, having performed visual observations of the project and performed and approved the required masonry inspection at the renovation, I hereby attest to the best of my knowledge, belief, and professional judgment, the structural and envelope components of the above referenced renovation are in compliance with the approved plans. I also attest that to the best of my knowledge, belief, and professional judgment, the approved permit plans represent the as built condition of the structural envelope component of the said structure. Please contact me at 305.310.5030 if you have any questions and/or comments. Sincerely, 041V Y7) Victor J. Bruce A.I.A., LEED R AP Architect AR -0017103 370 NE 10 Is' Street Miami Shores, Florida 33138 telephone 305-310-5030 tax 1-877-408-8280 email vbruce@ai-associates.net