BPP-13-1939Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-208878
Scheduled Inspection Date: March 20, 2014
Inspector: Rodriguez, Jorge
Owner: MELTZ, JONATHAN
Job Address: 157 NE 104 Street
MIAMI SHORES, FL 33138-2028
Project: <NONE>
Permit Number: BPP -8-13-1939
Permit Type: Pools/Whirlpools/Hot Tubs
Inspection Type: Final
Work Classification: Addition/Alteration
Phone Number
Parcel Number
1121360130750
Contractor: STAR -LITE POOL BUILDERS Phone: (954)747-3377
suiming uepanment comments
NEW Swimming POOL
INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-208636. CREATED AS
REINSPECTION FOR INSP-197979. Must pass electric and house alarms
Missing plumbing
Failed
Correction
Needed
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
reinspection fee is paid.
March 19, 2014 For Inspections please call: (305)7624949 Page 20 of 28
Miami Shores''Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
8OYIGtprLTa'f7'crl TC /L3/-/,0/7.
PERMIT APPLICATION
Permit Tyw: BUILDING
JOB ADDRESS: 157 NE 104 Street
? V3/13
ani
J-3 �L) LJ �a
eQk,,
FBC 20
Permit No.
Master Permit No.
ROOFING
City: Miami Shores County: Miami Dade gip: 33138
Folio/Parcel#
Is the Building Historically Designated: Yes NO Flood Zone:
OWNER: Name (Fee Simple Titleholder): Jonathan Meltz phot 786-269-5630
Address: 157 NE 104 STREET
City: MIAMI SHORES
State: FL Zip. 33138
Tenant/I.essee Name: N/A Phone#.
Email:
CONTRACTOR: Company Name. STAR -LITE POOL BUILDERS phot; 954747-3377
Address: 10875 NW 52 STREET SUITE 8
City: SUNRISE State. FL Zip: 33351
Qualifier. Name: RONALD M BIXLER phot 954747-3377
State Certification or Registration #: CPC056418 Certificate of Competency #:
Contact Phone#: 954-747-3377 Email Address: staditepoolbldrs@hotmail.com
DESIGNER: Architect/Engineer: DAVID FAERMAN phone#: 561445-1787
Value of Work for-tbis Permit: 00 C Square/Linear Footage of Work: t ��
Type of Work: OAddifion OAlteration ONew ORepair/Replace ODemolition
Description of Work: CONSTRUCT A NEW SWIMMING POOL AND DECK
Color thru tile:
Submittal Fee IS l� 9' Permit Fee $ CCF $ CO/CC $
Scanning Fee $ _ - Radon Fee $ 12.15— �.--- DBPR $ f �2. Z Bond $ 0
Notary $ cation Fee $ Technology Fee $ A C9
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $ "
Bonding Company's Name (if applicable) NA
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable) NA
Mortgage Lender's Address
City State
zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT:'
Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged
Owner or Agent
Contractor
The foregoing instrument was acknowledged before ire this '�D The foregoing instrument was acknowledged before me this-0—
day
hisday of JULY 20 by �'ea �� _ day of JULY .20 — by RONALD M BIXLER
who is personally known to me or who has produced, who is personally known to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign:
4Print: Print: DA E A MASKER
My Commission x DALE p� MASKER
Commission # EE 099428
Q Expires June 6, 2015
APPROVED BY ��e3 Plans Examiner
Structural Review
(Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
My Co s ""piiE A MASKER
Commission # EE t28,0,9ExpiresJune 6, 20��7i;dem�ar-
Zoning
Clerk
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
September 5, 2013
Permit No: BPP13-1939
Planning Critique
1. pool equipment can not be located within 10 feet of side plot line
David Daquisto
305-762-4864
Plan review is not complete, when all items above are corrected, we will do a complete
plan review.
If any sheets are voided, remove them from the plans and replace with new revised
sheets and include one set of voided sheets in the re -submittal drawings.
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
September 5, 2013
Permit No: RF13-1939
Building Critiaue Review
1. EQUIPMENT LOCATION SHOULD COMPLY WITH ZONING
REQUIREMENTS.
Plan review is not complete, when all items above are corrected, we will do a complete
plan review.
If any sheets are voided, remove them from the plans and replace with new revised
sheets and include one set of voided sheets in the re -submittal drawings.
01
ED
• Convenient Single Button Pass/Reset Operation
• 1 -Second Delay Allows for Adult Pass -Through
120 dB Alarm Siren - Minimum 95 A at,.10 Feet t
• Auto low Battery Chirp
• All Hardware Included for Gate, Door or Window Mount
Listed by ETL to UL 2017
• Water -Resistant
• Always On Device as Required by Barrier Codes
• Can be Manually Reset or will Automatically Reset in 3 Minutes to Continue Siren
• Alarm Goes Off Immediately When Triggered as Required by Barrier Codes
• Operates on One - 9 Volt Battery (not ind.)
• Bilingual Installation/Operation Manual (English/French)
• Bilingual 4 -Color Box (English/French)
MASTER CARTON WEIGHT 4 Ihs (6/Master)
UNIT BOX SIZE: 9.5° x 6° x 2°
UNITS/PALLET 960
MINIMUM ORDER: 1 Case (6 Units)
Contact Set Included
e 1111 282081611111 503 11 1.3
Pass Button Included
4
IMPORTANT
Keep the distance between the two pieces magnet
sensor contacts to a maximum of 3/4" -
Test the unit by opening the door. The alarm should
go off Immediately. Otherwise contact SmartPool Inc.
at 877-799-7665.
Do not rely on the alarm until the test results are
satisfactory.
LISTING REPORT
INTERTEK TESTING ZERYICES NA I
'
1950 EVERGREEN BLVD, SUITE 1-00
DULUTH,.-
Job No. 3020963-122 Issuedli
REPORT NO.30209;63A
INSPECTION, TESTS AND EVALUATION
OF
POOL ALARM QVQr=U
RENDERED TO'
SMARTPOOL, INC.
LAKEWOOD, NJ
GENERAL:* This Report gives the results of thq Inspection, tests ajR
of a Pool Alarm System for compliance with applicable requirep
Standard for Safety for General -Purpose Signaling Devices and Syst,
1" Ed., with revisions to 02/14/02). This Investigation was authorizect-I
dated 02127/02. The Investigation was begun on 63/07J02 and comply
03/08102. A production -line sample, in good condition, was provided I
Applicant on 02/28/02 and tested at ITSs Orlandq, FL, Facility.
c -
GENERAL -PURPOSE SIGNALING DEVICI�S AND SYSTEMS -
.
Applicant SmartPool, Inc.
575Prospect Shet, Suite 20
Lakewood, NJ 08701
Contact Mr.Richard Holstein, 7321730-9880 phone, 73217304
Manufacturer. Electronics Co.,Ltd.
Block 9 Zhu Yuan Industry Area
Guan Lan Town, Bao An Area
ShenZherl City; China
Contact Mr.Slu Ping Wong, 86-755-798555 phone, 86-755-7
An Independent organization testing for safety per ormance, and certIRC84
All services undertaken are sublaotta the following general policy* eports are submIttedf*
clients to whom they are addressed. Their significance ls:subject id the adequacy and reprw.'
of the samples and to the comprehensiveness of the tests, examinations or surveys made..)
not be reproducactexcept In Its entirety withoutwritten permlssion1frorn ITS.
I
o4l
Rick Scott
�; Governor
To pfotect, promote & improve the health
of all people In Florida through Integrated John H. Armstrong, MD, FACS
state, county & community efforts. HEALTH
State Surgeon General & Secretary
Vision: To be the Healthiest State in the Nation
August 15, 2013
Brian Ruff
10875 NW 52 Street
Miami, FL 33151
RE: Contingency Letter
Application Document No: API 116224
Centrax Permit Number: 13 -SC -1488013
OSTDS Number.
157 NE 104 St
Miami, FL 33138
Lot:22 23 Block: 121 Subdivision:
Dear Applicant:
This will acknowledge receipt of an application dated 08/05/2013 for a permit to use an
existing onsite sewage treatment and disposal system located on the above referenced
property.
From a review of your completed application, it has been determined your existing system is
adequate for the proposed use.
This permit is granted for the construction of a' new swimming pool. There will be no increase
in sewage flow or characteristics and no impact on the unobstructed area.
*********************APPROVED***************«.****
If you have any questions on this matter, please call our office at (305) 623-3500.
Sincerely,
Astrid Edwards, Engineer Supervisor III
Betsy Lange, Engineering Specialist II
Enclosures
cc:
Florida Departmental Health www.FlaridesHenith.com
in DADE COUNTY TWITTER:HealthyFLA
1725 NW 167 St, Opa Locks, FL 33056 %.'r
yr l M 100. 41'4nh
rRAWN
W. 7TH STREET, SUITE 202 �Ov a Surveyors, Inc.
FL 33126 SURVEY NO 13-000077-1
HONE: (305) 2642660
FAX
011) 2840228 44.
LAND
BY: LAND SURVEYORS SHEET NO 1 of 2
VEY OF LOT 22823, BLOCK 121, OF MIAMI SHORES SECTION FIVE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK
PAGE 47, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA.
PROPERTY ADDRESS: 157 NE 104 ST, MIAMI SHORES, FL 33138
FOR: JONATHAN MELTZ
LOCATION SKETCH Scale 1" = NT. S.
•rte � , '
SJT So
M
19�I1rcul,
s 1
a•
..
..
..
�..
,..
.,
sd
ss 3Y
sZ
tit
7
g
S
T
3
2
t
L.M.E. = LAKE MAINTENANCE EASEMENT
NV
RNV- RIGHT-OF-WAY
B.C. = BLOCK CORNER
L.P. = LIGHT POLE
SEC. = SECTION
B.C.R. = BROWARD COUNTY RECORDS
M. = MEASURED DISTANCE
S.I.P. = SET IRON PIPE L.B. #6044
n
M/H = MANHOLE
SWK - SIDEWALK
B.O.B. = BASIS OF BEARINGS
NAP. = NOT APART OF
T - TANGENT
C -CALCULATED
NGVD - NATIONAL GEODETIC VERTICAL
TWP = TOWNSHIP
C.B. = CATCH BASIN
I(0 .
f
5 3 %4-
..
..
..
.
A/C = AIR CONDITIONER PAD
..
so
N re} a3
sZ
tit
to
g
S
T
(a
ABBREVIATION AND MEANING
A = ARC
FNIP. = FEDERAL NATIONAL INSURANCE
RAD. = RADIUS OF RADIAL
A/C = AIR CONDITIONER PAD
PROGRAM
RGE. - RANGE
AE. =ANCHOR EASEMENT
IN.&EG. = INGRESS AND EGRESS
R.P. - RADIUS POINT
A/R =ALUMINIUM ROOF
EASEMENT
R.O.E. = ROOF OVERHANG
A/S = ALUMINIUM SHED
L.F.E. = LOWEST FLOOR ELEVATION
EASEMENT
ASPH. = ASPHALT
L.M.E. = LAKE MAINTENANCE EASEMENT
NV
RNV- RIGHT-OF-WAY
B.C. = BLOCK CORNER
L.P. = LIGHT POLE
SEC. = SECTION
B.C.R. = BROWARD COUNTY RECORDS
M. = MEASURED DISTANCE
S.I.P. = SET IRON PIPE L.B. #6044
B.M. = BENCH MARK
M/H = MANHOLE
SWK - SIDEWALK
B.O.B. = BASIS OF BEARINGS
NAP. = NOT APART OF
T - TANGENT
C -CALCULATED
NGVD - NATIONAL GEODETIC VERTICAL
TWP = TOWNSHIP
C.B. = CATCH BASIN
DATUM
U.E. = UTILITY EASEMENT
C.B.W. = CONCRETE BLOCK WALL
N.T.S. = NOT TO SCALE
U.P. = UTILITY POLE
CH = CHORD
O.H.L. - OVERHEAD UTILITY LINES
W.M. = WATER METER
CH.B. = CHORD BEARING
O.R.B. = OFFICIAL RECORD BOOK
W.R. = WOOD ROOF
CL = CLEAR
O/S = OFFSET
W.S. = WOOD SHED
C.L.F. = CHAIN LINK FENCE
OVH. = OVERHANG
C.M.E. = CANAL MAINTENANCE
P.B. = PLAT BOOK
eTX =
ANGLE
EASEMENTS
P.C. = POINT OF CURVE
A -CENTRAL ANGLE
CONC. = CONCRETE
P.C.C. = POINT OF. COMPOUND CURVE
C.P. = CONCRETE PORCH
PL. = PLANTER
g =CENTER LINE
C.S. = CONCRETE SLAB
P.L.S. = PROFESSIONAL LAND
41 =MONUMENT LINE
D.E. = DRAINAGE EASEMENT
SURVEYOR
D.M.E. - DRAINAGE MAINTENANCE
P.O.B.. - POINT OF BEGINNING
EASEMENTS
P.O.C.. - POINT OF COMMENCEMENT
DRIVE = DRIVEWAY
P.P. - POWER POLE
ENCR =ENCROACHMENT
P.P.S.. - POOL PUMP SLAB
E.T.P. = ELECTRIC TRANSFORMER PAD
P.R.C. = POINT OF REVERSE CURVE
F.F.E. = FINISHED FLOOR ELEVATION
PRM - PERMANENT REFERENCE
F.H. - FIRE HYDRANT
MONUMENT
F.I.P. = FOUND IRON PIPE
PT. = POINT OF TANGENCY
F.I.R. = FOUND IRON ROD
PVMT. = PAVEMENT
F.N. = FOUND NAIL
PWY - PARKWAY
F.N.D. = FOUND NAIL & DISK
R = RECORD DISTANCE
LEGAL NOTES TO ACCOMPANY SKETCH F
SURVEY P•gI Ievaw,
- THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY.
- THE PURPOSE OF THIS SURVEY IS FOR USE IN OBTAINING TITLE INSURANCE AND FINANCING, AND SHOULD NOT BE
USED FOR CONSTRUCTION PURPOSES.
- EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY,
AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS
OR EASEMENTS OF RECORD, AND LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY.
BOUNDARY SURVEY MEANS A DRAWING AND / OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN
- THE FIELD, COULD BE DRAWN AT A SHOWN SCALE AND / OR NOT TO SCALE.
EASEMENTS AS SHOWN ARE PER PLAT BOOK UNLESS OTHERWISE SHOWN.
- THE TERM "ENCROACHMENT" MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS.
- ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS AND SETBACKS, AND THEY WILL BE RESPONSIBLE
- FOR SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THFIR APPROVAL FOR AUTHORIZATION TC
AUTHORITiE b IN NEW CONSTRUCTIONS, UNLESS OTHERWISE NOTED. THIS FIRM HAS NOT ATTEMPTED TO LOCATE
FOOTING AND/OR FOUNDATIONS.
FENCE OWNERSHIP NOT DETERMINED.
- THIS PLAN OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED.
- HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY.
- THE SURVEYOR MAKES NO GUARANTEES AS TO THE ACCURACY OF THE INFORMATION BELOW. THE LOCAL F.E.MA
- AGENT SHOULD BE CONTACTED FOR VERIFICATION. THE FNIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED
LAND TO BE SITUATED IN ZONE: X COMMUNITY/PANEL/SUFFIX: 120880 0302 L DATE OF FIRM: 09/1112009
BASE FLOOD ELEVATION: WA
CERTIFIED TO: JONATHAN MELTZ
LEGEND TYPICAL
-ON- OVERHEAD UTILITY LINES
2=zz C.B.S. -WALL (CBWI
C.L.F. -CHAIN LINK FENCE
"tea I.F. - IRON FENCE
W.F. = WOOD FENCE
■ OAO = EXISTING ELEVATIONS
SURVEYOR'S NOTES
W
W
LJ
1) IF SHOWN, BEARINGS ARE REFERRED TO AN ASSUMED
MERIDIAN, BY SAID PLAT IN THE DESCRIPTION OF THE
PROPERTY. IF NOT, THEN BEARINGS ARE REFERRED TO
COUNTY, TOWNSHIP MAPS.
2) THIS IS A SPECIFIC PURPOSE SURVEY.
3) THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE
1:7500 FT.
4) IF SHOWN, ELEVATIONS ARE REFERRED TO
MIAMFDADE COUNTY.
ALL ELEVATIONS SHOWN ARE REFERRED TO
NATIONAL GEODETIC VERTICAL DATUM OF 1929
MIAMI-DADE BENCH MARK #N -W7
LOCATOR#3100
ELEVATION 10.54 FEET OF N.G.V.D. OF 1929
SURVEYOR'S CERTIFICATIO
1 HEREBY CERTIFY: THAT THIS "BOUNDARY SURVEY" OF
THE PROPERTY DESCRIBED HEREON, AS RECENTLY
SURVEYED AND DRAWN UNDER MY SUPERVISION,
COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS
AS SET FORTH BY THE FLORIDA BOARD OF
PROFESSIONAL LAND SURVEYORS IN CHAPTER 61017-6,
FLORIDA ADMINISTRATIVE CODE PURSUANT TO 472.027,
FLORIDA STATUTES.
BY'.
PROFESSIONAL LAND SURVEYOR NO. 6437
STATE OF FLORIDA (VALID COPIES OF THIS SURVEY WILL
BEAR THE EMBOSSED SEAL OF THE ATTESTING LAND
SURVEYOR).
REVISED ON:
REVISED ON:
NO. 6437
STATEN
SURVEYOR'S SEAL
1,AZDEPARTb1ENTOFHOMELAND SEg1RITY ELEVATION CERTIFICATE
FEDERAL ElIE mmy MANAeEMENT AOIENCY OMB No. 1660-0008
National FToad lkwmwe Program Important: Read the Instructions on pages 1-9. Expiration Date: July 31, 2015
SECTION A - PROPERTY INFORMATION
Al. Building Owner's Name JONATHAN MELTZ w
e
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
157 NE 104 ST' '
9�
City MIAMI SHORES State FL ZIP Code 33138
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
LOT 22&23, BLOCK 121, MIAMI SHORES SEC 5, BOOK 10, PG 47, MIAMI-DADE, FL
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL
A5. Latitude/Longitude: Lad. 25'52'15.09'N Long. 80'11'39.98"W Horizontal Datum: ❑ NAD 1927 ® NAD 1983
A6. Attach at least 2 photographs of the building 9 the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 8
A8. For a building with a c. awlspace or enclosum(s): A9. For a building with an attached garage:
a) Square footage of crawlspace or enclosure(s) 1210. sq it a) Square footage of attached garage WA sq ft
b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage
or enclosure(s) within 1.0 foot above adjacent grade Z within 1.0 foot above adjacent grade WA
c) Total net area of flood openings in A8.b 1210, sq in c) Total net area of flood openings in A9.b WA sq in
d) Engineered flood openings? ❑ Yes ® No d) Engineered flood openings? ❑ Yes ® No
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number B2. County Name B3. State
MIAMI SHORES 120650 1 MIAMI-DADE I FL
B4. Map/panel Number
B5. Suffix
B6. FIRM Index Date
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s) (Zone
12086C0302
L
09/11/2009
I
Effective/Revised Date
Zone(s)
1
AO, use base flood depth)
12.91.
® feet
❑ meters
09/11/2009
X
WA
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9.
❑ FIS Profile 19 FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
B12. Is the building Dated 16'a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No
Designation Date:Ij` IA ❑ CBRS ❑ OPA
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction' ® Finished Construction
`A new Elevation Certificate will be required when construction of the building Is complete.
C2. Elevations - Zones Al -A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, ARIA, ARAE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h
below according to the building diagram specified In Item A7. In Puerto Rico only, enter meters.
Benchmark Utilized: 1,+567 Vertical Datum: NGVD 1929
Indicate elevation datum used for the elevations in items a) through h) below. ® NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (Including basement, cxawispace, or enclosure floor)
b) Top of the next higher floor
c) Bottom of the lowest horizontal structural member (V Zones only)
d) Attached garage (top of slab)
e) Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment and location in Comments)
t) Lowest adjacent (finished) grade next to building (LAG)
g) Highest adjacent (finished) grade next to building (HAG)
h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support
11.15.
® feet
❑ meters
13.25.
® feet
❑ meters
121A.
® feet
❑ meters
10.82.
® feet
❑ meters
12.91.
® feet
❑ meters
10.5.
® feet
❑ meters
10.70.
® feet
❑ meters
10.50.
® feet
❑ meters
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation
information. 1 certify that the Information on this Ceidlicate represents my best efforts to interpret the data available.
1 understand that any false statement may be punishable by fine or imprisonment under 18 U.S Code, Section 1001.
® Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a
❑ Check here if attachments. licensed land surveyor? ® Yes ❑ No
Certifiers Name GEORGE MARRA License Number 2534
Title LAND SURVEYOR Company Name NOVA SURVEYORS INC.
Address 5W54w 7T" ST, SUITE $02 City MIAMI State FL ZIP Code 33126
Date 07/03/2013 Telephone (305) 2642660
7/3{►3
J
FEMA Form 086-0-33 (7/12) See reverse side for continuation. Replaces all previous editions.
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
NOTICE OF REQUIREMENTS
RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT
(We) acknowledge that a new swimming pool, spa or hot tub will be constructed or Installed at
157 NE 104 STREET
Miami Shores, FL, and hereby
affirm that one of the following methods will be used to meet the requirements of Chapter 515,
Florida Statues and the Florida Building Code R4101.17.
Please initial the method(s) to be used:
The pool will be equipped with an approved safety pool cover that comp lies with ASTM
F1346.91. (Submit Manufacturer's Specifications).
A continuous, one-piece (child) barrier meeting the requirements of Florida Building Code
R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location and method of
attachment, including one end that shall not be removable without the aid of tools. (Submit Manufacturer's
Specifications).
A combination of non -dwelling walls and fences (screen enclosure, gild fence, masonry
fence walls, chain link or wood fence, etc.) will protect t he pool perimeter. The plans must specify t he type
and location of all non dwelling walls. Florida Building Code, R4101.17.1
JA - Any combination of protection which incorporates dwelling walls with openings directly into the
pool perimeter and all windows and doors will be equipped with exit alarms complying with Florida Building
Code, R4101.17.1.9 (Submit Manufacturer's Spec cations).
Any combination of protection which incorporates dwelling walls with openings directly into the
pool perimeter and all doors will be equipped with a self -latching device with positive mechanical
latching/locking installed a min. 54° above the threshold. If this option is selected, submit plans showing all
types and location of all perimeter protection. The plans must also show the location and type of all
openings, and the hardware type for each location. (Submit Manufacturer's Specifications).
In accordance with the Code, the pool may not be filled with water without compliance with the
Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be
presumed to be unsafe. I understand that not having one of the above installed will constitute a
violation of Chapter 515, F.S ., an d will be considered as committing a misdemeanor of the second
degree, punishable as provided in Section 775.082 or Section 775.083 F.S . This form m st be signed
by er/agent and the prime contractor.
CONTRACTOR'S SIGNATURE AND DATE
M BIXLER
DALE A. MASKER
Commission # EE 099428
Expires June 6, 2015
BMWW Ties Tmy FWn Ins aanm 800 365.7019
LIZ ler-'4
OWNER'S SIGNATURE AND DATE
JONATHAN MELTZ
OWN E ' M INT)
DALE A MASKER
:•z Commission # EE 099428
o= Expires June 6, 2015
Bm" Ttau Tmy Fain h=rm8w.365.7019
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
SWIMMING POOL OWNER'S CERTIFICATION
Date g 1".LP.-5jo
Miami Shores Village
Building & Zoning Department
Attention: Building Official
I certify that I am the legal owner of the property described as
157 NE 104 STREET . located at
In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that
understand and agree that the swimming pool to be constructed at the above address cannot
be used or filled with water until separate permit has been obtained for an approved safety
barrier, and such barrier erected, inspected and approved.
I further understand that this certification, however, does not eliminate the need for
obtaining a permit and erecting and approved barrier prior to final inspection and use of the
Legal
Note: This certification is to be submitted with a swimrr
.4
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE
KNOW ALL MEN BY THESE PRESENTS:
WHEREAS, the undersig JONATHAN MELTZ Were the fee
simple owner(s) of the followring described property situated and being in Miami Shores VtUage, Florida
Address: 157 NE 104 STREET
Whereas, the undersigned owners)
JONATHAN MELTZ
desire to utilize said Lots) as a single building site, and the undersigned owner(s) do(es) hereby declare and agree as follows:
1. That the property will not be used in violation of any ordinances of Miamb Shores Village or Miami -Dade
County now in effect or hereinafter enacted.
II. That the purpose of the covenant is to induce Miami Shores Village to Issue a permit for a pool where the
required enclosure is not on the subject property where the pool is locate/.
III. That if any of our adjoining neighbors remove any portion of their fence or wall, or if our/my property shall fail
to meet code requirements for pool barriers, we, as owners will immediately install a protective enclosure to
meet code requirements and will obtain a permit for such fence.
IV. That, Uwe, as owner(s) hold Miami Shores Village harmless for any negligence or injury that results from not
having the enclosure.
V. If enclosure belongs to said properly, I agree to maintain & or replace said enclosure in the event that is
damaged or removed by any rase.
NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not
convey or cause to be conveyed the title to the above property without requiring the sumer in title to abide by all terms and
conditions set forth herein.
FURTHER, the undersigned declare(s) that this covenant is Intended and shall constitute a restrictive covenant
concerning the use, enjoyment and title to the above property and shall constitute a covenant running with the land and shall be
binding upon the undersigned, his/her successors and assigns and may only be released by Miami Shores Village, or its
successors, in accordance of said Village then in effect. n ® „
OWNER SIGN & PRINT
I Hereb C�e! �' ►that on this day �rsenafiy appeared before me jYXA� �ftolid has produced ID
# '(t .1U L as identification and he/she acimowledge that he/she executed the foregoing, freely and voluntarily,
for purposes there in expressed.
SWORN TO AND SUBSCRIBED before me on this day of
40TARY PUBLIC ATE OF FLORIDA
(Revised 05/2209
NOTE:
POOL TYPE "�° 1HAS EDNBEMUITNPLPIPING
BENESIGED ASD ON THE MAXIMUM OW CAPACITY OF THE NEW SWMMINGOOLPUMP.
NON DIVING
ALL DOORS AND WINDOWS
PROVIDING ACCESS TO POOL
SHALL HAVE DOOR & WINDOW ALARMS
PER F.B.C. 2010
(NOTE: SEE PG -2 FOR POOL SPECIFICATIONS)
F.F.E. 11.15'
RESIDENCE
POOL PLAN
SCALE: VW a 1•-0•
NMTH
0
EXISTING
FENCE
r -------
16'
f -
I
10.65' I
I
I
16'
21'
S' TANNING STEP —/
W/ UMBRELLA HOLDER
Lu I
3 I
;n Q I
1� 21'-6"
LONG
MD b-
1
Z CJi
og�
*-' -
OR
PADS
SIZE
N.T.S.
7'-10" -
7'-6" MIN.
—2„ FROM PL
DECK JET
/2.5' DECK
..fes
ENGINEERS NOTE:
ENGINEER REQUIRES CONTRACTOR BUILDS
FROM PLANS AS APPROVED BY THE LOCAL BUILDING
DEPARTMENT. THE ENGINEER IS NOT RESPONSIBLE FOR
CONSTRUCTION ERRORS RESULTING FROM FAILURE TO
COMPLY WITH THIS RECOMMENDATION.
LANDSCAPE
SCREEN AS
PER CODE
10'-10"
WELL POINT
SEE DETAIL / EXISTING
FENCE
L CLEANING LINE
W/ VAC -LOCK
INSTALLED BETWEEN
6" AND 18" BELOW POOL
WATER LINE PER F.B.C. 2010
JET
NOTE:
EXISTING FENCE MUST BE MIN. 48" HIGH
W/ GATES MIN. 48" HIGH W/ SELF
CLOSING, SELF LATCHING DEVICE
AT MIN. 54"
NOTE:
TOP OF POOL ELEVATION IS MIN. 6"
LOWER THAN F.F.E. OF HOUSE
18" SWIMOUT W/
CONTRASTING EDGE
SEE DETAIL
SEP 12 2013 HYDRAULIC UPLIFT COMPUTATIONS a0 LA•d'ATION OF LLASHM
e FLOOD CREST ELV. FOR AREA - FLOOD ZONE " X " ~ B'�� .,,E� "°.TMS °AAN°"°'"E°"mea
TOP OF POOL ELV. = 10.65' m 1) THE ENGINEER DOES NOT REVMW 11-M DRAVOWS FOR COMMANCE wnTH W CONTRACrORS
BOTTOM OF POOL ELV. = 5.65' RBQIM MMM ORHOMMONEWRO"EMENTSRELATED mn+EPC%MD/ORSPA.
HYDRAULIC HEAD = N/A a)T"EwnnaACTMM "ARznYCW4PL CEWrTHSEISAW
ALLOWANCE HYDROSTATIC VALVE = -2.0` 3) MNG NEER IS NOT RESPONSIBLE FOR AND HAS NO UfABIUiY FOR OMMUCIION
NET HYDRAULIC HEAD = N/A roNw smwm ON im PLANS.sPEc�IC REQun ts. OR HOMr�vaN� REQ>nREMEUTs
4) THE ENSINE?R REVIEWS THE PIANS FOA COOS COMPLIANCE TO THE BEST OF
USE MIN. 6" THICK CONCRETE FLOOR SLAB HSKNOWLEOM
5) REGARDLESS OF THE CAUSE, THE ENGINEERS LIABILITY IN REATWN TO THESE
(NOTE: PROPERTY IS LOCATED IN FLOOgS4y io ��s oPLMISLIMMTO'ME LESSOR OF»ORMPEE awaG®FMnlEKAM.
FA
s
DATE DESCRIPTION BY ee `,. . • ° ° • ° • ' ° . `•, j
CITY CORRECTION REL00k M EQUIPMENT NAME: MELTZ LOT:POOL Ns157 N.E. 104th STREETA 9/9/13 MSW BLOC
K.
B ' e.,';; .* � ,zr : e �0 CITY/STATE: MIAMI SHORES, FL, BOOK
.`;•"," .
A 6 STAR -LTTE POOLS BUILDERS 33138
C _ 10875 N.W. 52nd STREET SUITE #8 JOB*: 13-3905-18 PAGE:
D DAVID FAERMAN (P.E. 47646) e e SUNRISE, FL 33351 SUBDIVISION:
° /, , o (954) 747-3377
E 22171 WATERSIDE DRIVE o (�® °
SOCA RATON, FL. 33428 ��,ggr�T e®
F PHONE: 561-445-1787 s�,i�osY�'�NSE� \�ee DATE:07/10/13 MIAMI -DADS FSHEET: 1 OF 5
` fialso®®8®°
SEP 182013
BYE
F
SPECIFICATIONS
POOL SIZE: I 15'X 0' POOL DEPTH: I T TO 5'
POOL PERIMETER: 90 LF
POOL AREA SQ. FT.: 437S
VOLUME: (GALLONS) ®
TURNOVER RATE 3.46 HRS
POOL EQUIPMENT
AUXILLIARY POOL EQUIPMENT
POOL PUMP: I 1 HP -PEE
AUX. POOL PERIMETER: N/A
POOL FILTER: 1 90 SF CART.
AUXILLIARY PUMP: I N/A
POOL INLETS: 1 4 1
AUX. POOL JETS: IN A
SKIMMER: r 1 — I
AUX. POOL LIGHT: IN A
POOL LIGHT: 2 -COLOR LED
AUX. HEATER TYPE: N/A
POOL HEATER:
AUX. HEATER SIZE: q
POOL HEATER SIZE:—N//1 �I
RAISED: N/A
CLEANING LINE: VAC
STEP(S): N/A
CLEANING SYSTEM: N/A
BLOWER: N/A7771
CHLORINATOR: IN-LINE SALT
TURNOVER RATE: I N/A
POOL FINISH ITEMS
COPING: TUMBLED MARBLE
HANDHOLDS:
TILE: 6-7-7-1
INTE
SWIMOUT:
D -CK S.F.: 1069 SF 1
LADDER: A A
CAPPING '
HANDRAIL: N A
DECK TYPE: TUMBLED MARBLE
WATER FEATURES
AUX. POOL
SPILLWAY SIZE: N/A
FOUNTAIN FEATURE:
LIONS HEAD: N/A
SHEER DESCENT: N/A
SPRITZER/SPRAY HEAD: 2 -DECK JETS
FEATURE PUMP: N/A
THERAPYJETS: N A
OTHER: r TANNING STEP
LIGHT FEATURES
FIBER OPTIC SPOT(S): N A REMOTE : N A COLOR WHEEL: N/A
PERIMETER LIGHTS: N A GHT SWITCH: YES # OF COLORS: N/A
ADDITIONAL FEATURES
POOL ENCLOSURE: FENCE ALARMS GLASS BLOCK TYPE: N/A
FOOTERS L.F.: N/A GLASS ROWS HT: N/A
DECO -O -DRAIN: N/A GLASS ROWS WDTH. N/A
PILING POOL: N/A # OF GLASS BLOCKS. N/A
CONSTRUCTION NOTES
1. POOL ENCLOSURE (FENCE/ALARMS) SHALL MEET REQUIREMENTS OF
GENERAL NOTE 29.
2. TRIM TILE ON STEPS AND BENCH.
e°e`�p �••
FAEi4
�•
ve e•
DATE DESCRIPTION BY
L
I !•.
POOL �tAa
��Q •' \ s�e°•�/j♦®
i o
NAME• MELTZ
LOT:
A 9/9/13 MSW•�6s�,•.g'
;.;�fi'
^*' : i� +='
.�,+'+�: ••°
PLANS " `"` ' ` �'�f`
:
. 47646
• ' ° "
* . e � .
STAR -LITE POOLS BUILDERS
157 N.E. 104th STREET
CITY/STATE: MIAMI SHORES FL
33138 '
BLOCK:
BOOK:
B
C
s
' ' •
10875 N.W. 52nd STREET SUITE #8
suNRlse, FL 33351
JOB#: 13-3905-18
PAGE:
D
DAVID FAERMAN (P.E. 47646)
22171 WATERSIDE DRIVE
��
° Q ���
♦i � ;•+•' °
����
(954) 747-3377
1
SUBDIVISION:
SUBDIVISION:O
E
BOCA RATON, FL. 33428
PHONE: 561-445-1787
* mmtt��\e°°
o°
DATE: 07/10/13
COUNTY:
MIAMI-DADE
SHEET:20F 5
F
-LEGEND
❑ 2 WAY VALVE
0 CHECK VALVE
3 WAY VALVE
PLUG OR
HYDROSTATIC
VALVE 1-1/2"
IN-LINE
NOTE:
IN ACCORDANCE WITH ANSVAPSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE, THE POOL PIPING
HAS BEEN DESIGNED BASED ON THE MAXIMUM FLOW CAPACITY OF THE NEW SWIMMING POOL PUMP.
1
SKIMMER TO HAVE VENT HOLES IN LID
(2) HAYWARD WG-104SE
MAX. 125 GPM PER DRAIN 3' "
ASME/ANSI A 112.19.8 MIN,
APPROVED MAIN DRAIN COVERS
(OR EQUAL)
MINIMUM T APART.
INSIDE EDGE OF
DRAIN TO INSIDE
EDGE OF DRAIN OR
ON SEPARATE
a AFJPQ
ASME/ANSI APPROVED COVER
TO BE FASTENED
WITH SCREWS
WELL POINT��� '-ROCK BED
WELL POINT DETAIL
N.T.S.
It
I
PRESSURE GAUGE AND
AIR RELIEF VALVE
FILTER
9TV
0.01
PIPING SCHEMATIC
POOL
PLANS
DAVID FAERMAN (P.E. 47646)
22171 WATERSIDE DRIVE
BOCA RATON, FL, 33428
PHONE: 561-445-1787
VELOCITY CHART PER ANSI/APSP-7 SECTION 4.4
PIPE
FLOW RATE
FLOW VELOCITY
2" INLETS
63 GPM
6.00 FEET PER SECOND
2" DECK JETS
63 GPM
6.00 FEET PER SECOND
2" SKIMMER
63 GPM
6.00 FEET PER SECOND
2" CLEANER
63 GPM
6.00 FEET PER SECOND
2" MAIN DRAIN
63 GPM
6.00 FEET PER SECOND
2" M.D. BRANCH
63 GPM
6.00 FEET PER SECOND
EVALUATION FOR COMPLIANCE WITH APSP-15 - ENERGY EFFICIENCY
VOLUME OF POOL d 13,075 GALLONS
PUMP DESIGN FLOW RATE AT LOW SPEED: 25 GPM
TURNOVER RATE AT LOW SPEED: 8.71 HOURS
THUS, PUMP SPECIFIED COMPLIES WITH APSP-15
1 HP HAYWARD SUPER (SP2607X102S)
PUMP W[
WHIR&INT
STRAINER
3 GPM i4rX. POW RATE
%%% AER eo
®s
Q ;.•••rte tiI,9 ®io
e J ° • E N S� °.� o0
° �
e �
e o � e s
• No.
o
-10
® STavid t. Feern(,a
s •
®� ,c FL, UCAS
°®Bsasasc�'
STAR -LITE POOLS BUILDERS
10875 N.W. 52nd STREET SUITE 48
SUNRISE, FL 33351
(954)747.3377
NAME: MELTZ
157 N.E. 104th STREET
CITY/STATE: MIAMI SHORES, FL,
33138
JOB#: 13-3905-18
DATE:07/10/13
PUMP FRAME FILTER TANK
MOUNT ANO HEATER IF SPECIFIED
13/40 x 3/16' TAP CON.
REINFORCED CONC. SIRE
MINIMAL 4• THICK
�I►na
� PUMP
AKPO,OVL FILTER
AANND�TMEEk ANCHOR HEATER
POINOTES: ANCHOR BOLTS THROUGH
BASE (13/4" x 3/16")
FOR POOL PUMP & F
HEATER AP COSHOWN AS OPTIONAL ILII R
L
1 1/2" ANGLE BRACKETS rMf
HEATER)
) 21/2" ANGLE BRACKETS TPUMP)ITH ({4) 13/40 x 3/16" TAP AND
(4) 1/20 SELF TAPPING SHEET METAL SCREWS.
POOL EQUIPMENT ANCHORING
V&
NOTE: SKIMMER TO NAVE VENT HOLES IN UO
SKIMMER DETAIL
N.T.S.
LOT:
BLOCK:
BOOK:
PAGE:
COUNTY:
MIAMI-DADE , SHEET:3 OF 5
2
12"
(SEE TYPICAL WALL SECTION)
POOL STEP DETAIL N.T.s.
WP MANUAL STARTER SWITCH (TYP)
PANEL
WP GFI & TO
20' FROM WATEF
?-,
46" MIN.
Mr7..
z
g r POOL
� LI DECK
LOXES-12VTRANS.
3 412 IN 1/2-
I" NON -CORROSIVE
W/
1 HP 2 -SPEED
(2) LED COLOR POOL LIGHT
W/ LOW WATER
CUT OFF DEVICE
ELECTRICAL DIAGRAM
NOTE:
1. BOND ALL BOXES,RAILS,UGHTS,STEEL ET.
W/ 48 WIRE IN POOL AREA.
2. POOL LOCATION MUST COMPLY WITH NEC
2008 CODE, ESPECIALLY NEC 680.
DATE DESCRIPTION BY
POOL
PLANS
ff rrWl`
DAVID FAERMAN (P.E. 47646)
22171 WATERSIDE DRIVE
SOCA RATON, FL. 33428
PHONE: 561-445-1787
APPROVED CONNECTORS CLAMPS
OR WELDING AT ALL JOINTS. DECK,
\
INSIDE WAIL
SLOP r
e►
It
AWG WIRE PERIMETER OF POOL
TOP
VIEW
BONDING DETAIL
M.T.S.
(PER N.E.C. 2008 680.26 EQUIPOTENTIAL BONDING)
� 18°
CONTRASTING
EDGE
SWIMOUT DETAIL
N.T.S.
,eT®aaaaoeasB°,°
s o 6
0 646 °•
10 8/22/13 �r o
o ®I rha e, P. ®®
®%- , -gip * $ ®®®
1.43 CONT.
TUMBLED MARBLE
COPING
PATIO SET IN SAND
ON COMPACTED FILL
TILE
TER LINE ...
SLOPE
—
5" TO 6"
MINV RTICAL
2' -3" SHALLOW END
T-0' DEEP END
2" COVER (CENTER)
APPROVED 'P 5" TOP & 6' BOTTOM
FINISH W/ 43 AT 12" O.C.
/ EACH WAY.
STEEI.TEX FORM,
�– KRAFTBOARD OR EQUIV.
43 AT 12' O.C.
6° N. E.W. BOTI. CENTERED
TYPICAL WALL SECTION
DECK BONDING NOTE
(1) ATTACH TO THE POOL REINFORCING STEEL (SINGLE 88 A%VG WIRE)
(2) BURIED TO A MIN. DEPTH OF 4• TO 6• BELOW GRADE.
(3) MIN. OF 4 POINTS UNIFORMLY SPACED AROUND PERIMETER OF POOL AND SPA.
FOR NONCONDUCTIVE POOL SHELLS (FIBERGLASS, ECT.) BONDING AT FOUR POINTS SHALT. NOT BE REQUIRED.
(4) CONNECTED W/ SINGLE k8 AWG WIRE WITH A SOLID COPPER BARE CONDUCTOR
NOT SMALLER THAN i8 AWG.
(S) CONNECTION SHALL BE MADE EXOTHERMIC WELDING OR BY LISTED PRESSURE CONNECTORS
OR CLAMPS THAT ARE LABELED AS BEING SUITABLE FOR THE PURPOSE AND
ARE OF STAINLESS STEEL, BRASS, COPPER, OR COPPER ALLOY.
(6) THE *8 AWG WIRE SHALL EXTEND UNDER PAVED AND UNPAVED WALKING SURFACES
BETWEEN 18• TO 24' HORIZONTALLY BEYOND THE INSIDE WALL OF POOL OR SPA.
(PER N.E.C. 2008 680.26 EQUIPOTENTIAL BONDING)
STAR -LITE POOLS BUILDERS
10875 N.W. 52nd STREET SUITE 48
SUNRISE, FL 333SI
(954) 747.3377
IMPORTANT NOTE:
NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL
LESS THAN V-0' DEEP AND SPECIFICALLY DESIGNED FOR
DIVING. THIS POOL IS NOT DESIGNED FOR DIVING.
30'
7' 15'-6• a 6'
WATER
1:7 MAXIMUM SLOPE
lie SLOPE
LONGITUDINAL POOL SECTION (TYP.) MAA
N.T.S.
NAME: MELTZ
157 N.E. 104th STREET
CITY/STATE: MIAMI SHORES, FL,
33138
30B#: 13.3905-18
DATE:07/10/13
LOT:
BLOCK:
BOOK:
PAGE:
MIAMI-DADE
SHEET40F 5
1. (:ODE REQUIREMENTS- Private swimming pool and spas must comply with chapter 424 & 84101 Florida Building Code,
2010.
2. Mechanical Reaubeale6ta All piping, equipment and materials used In the plumbing system of swimming pools (Spas) that
are built In place shall conform to the Florida Building Code, Plumbing. All piping materials shall be
Installed In strict accordance with the manufacturer's Installation standards.
3. Compliance- AN materials, piping, values, equipment or appliances entering Into the construction of swimming pools (Spas)
or portions thereof shall be of a type complying with the code or of a type recommended and approved by a nationally
recognized testing agency or conforming to other recognized standards acceptable to the administrative authority.
4. gnalneerIng Design- Design, Construction and workmanship shall be In conformity with ANSI / NSPI 3,4,5,6 & 7 2006
• published by the International Aquatics Foundation, or other accepted engineering practices.
S. ENTRAPMENT Testing and CertificattonAll pool and spa suction Inlets shall be provided with a cover that has been tested
and accepted by a recognized testing facility and comply with ANSI/ASME A112.19.8, "Suction Fittings for Use In
Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Appliances." Exception: Surface Skimmers.
6. Safety Note: Do not use or operate pool or spa if the suction Inlet fitting Is missing, broken, or loose.
7. Suction, Inlet Per Pumpper FSC R4101.6.6 A minimum of two suction Inlets shall be provided for each
pump In the suction Inlet system, separated by a minimum of 3 feet or located on two different planes. i.e., one on the
bottom and one on the vertical wall, or one on each of two separate vertical wails. These suction Inlets shall be plumbed
such that water Is drawn through them simultaneously through a common line to the pump.
8. CleaQgr F ttlanper FBC R4101.6.6 Where provided, the vacuum or pressure cleaner fitting(s) shall be
located In an accessible position at least 6 Inches and not greater than 18 Inches below the minimum operating watedevel or
as an attachment to the skimmer(s). All cleaner suction Inlets shall be protected by an approved, permanently Installed,
self-closing self latching flapper assembly compliant w / WPMO SPS 4.
9.yalveVelves shall be made of materials that are approved In the Florida Building Code 2010,
Plumbing. Valves located under concrete slabs shall be set in a pit having a least dimension of five pipe diameters, minimum
10 Inches, fitted with a suitable cover.
10. WAste Water Djsoosal- Direct or indirect connections cannot be made to existing facilities
without the prior approval of the administrative authority.
11. Water Service Backflow prevention device is required on all potable water
service.
12. Tests . All pool piping shall be Inspected and approved before cover or concealment. It shall be tested and proved tight
under a static water or air pressure test of not less than 35 psi for 15 minutes. Per manufacturer's recommendations, no air
test shall be approved for PVC pipe and fittings.
13. -Water Heating Eauloment Swimming pool water heating equipment shall conform to the design construction and installation
requirements in accordance with accepted engineering practices, shall bear the label of a recognized testing agency and
shall Include a consideration of combustion air, venting and gas supply requirements for water heaters.
It must contain a thermostatic or high-pressure control switch so the pool water does not exceed 104
degrees F. water heating equipment shall be installed with flanges or union connections
adjacent to the heater. All heaters must have an internal check valve.
14. Gas Pioina- Gas piping shall comply with the Florida Building Code 2010, Fuel Gas See.
15. Eleclsdo - Pool location and Electrical wiring and equipment shall comply with latest edition of the National Electrical Code, section
680.
16. Ladders and Stem - All pools shall be provided with a ladder or steps in the shallow
end where the water exceeds 24 Inches. Where water depth exceeds 5 feet, there shall be ladders, stales or underwater
benches / swimouts In the deep end.
17. Jfi= - The entire design of matched components shall have sulftclent capacity to
provide a complete turnover of pool water in 12 hours or less.
18. Pool ,Flttinas - Pool fittings shall be of an approved type and design as to be
appropriate for the specific applicatlonPurple primer required on PVC piping.
19. ,Ls. Skimmers shall be installed on the basis of one per 800 SF of
surface area or fraction thereof.
20. Hydrostatic Retjef Device- In areas of anticipated water table, an approved
hydrostatic relief device shall be installed. Exception is plastic liner pools.
21. Concrete /Steel - Concrete is to be a mix designed In accordance with ASTM C-94 by a recognized testing
laboratory to achieve a strength of 3000 psi, at 28 days, (unless otherwise noted) with a plastic and workable mix.
Pneumatically applied concrete and/or shotcrete shall be placed in accordance with ACI 304.2R-04 and ACI 506.2-04,
respectively. All other concrete shall be placed in accordance with ACI 304R-04. A certificate of manufacturer's mix and
strength Is to be provided. No water Is to be added after truck leaves plant without approval of the engineer. Plant control
Is required. Maximum mix time at point of deposit is 90 minutes. Concrete work shall be as per requirements and
recommendations of ACI 301-04. (REINFORCING, DEFORMED STEEL) bars shall be A615 Grade 60 (unless otherwise
noted), free from oil, loose scale and loose rust. Reinforcing, deformed steel bars shall be bent, lapped, placed, supported
and fastened according to the Manuel of Standard Practice for Detailing Concrete Structures (ACI 315-04) and the building
code requirements for reinforced concrete (ACI -318-04). in case of conflict, the more conservative value(s) shall be used.
22. Sajl Statement- In accordance with FOC 2010 Section 1818, HVHZ Bearing Capacity of Soil: Based upon rational analysis,
the In-place soil beneath the pool Is sand and Ilmestome and has an acceptable bearing capacity of $50 psf and 2000 psf for related
structures shown within these pians, excavation and compaction In accordance with current edition of FBG. Should any muck, mart, or other
organic soils be discovered on excavation, they should be removed In their entirety, All construction shall stop and the
engineer of record shall be contacted to conduct an inspection.
Structural elements are designed with a required bearing capacity as stated above, unless otherwise specified. Fiberglass
and vinyl liner pools require 250 psf safe bearing capacity unless otherwise specified.
23. pool Staklna - This design engineer assumes no responsibility for pool construction in easements or required setback areas.
Piot plans not prepared from legal surveys of the existing lot and residence are so indicated. The pool contractor shall
verify all dimensions in the field and establish lot lines. The pool contractor shall establish locations of all utilities at the site.
and contact the Engineer if different than Indicated on plan. Min. clearance dimensions shall be held as required by the local
regulatory agency.
24. Existing Structures- The pool contractor shall always take all precautions to protect existing structures from failure by
sheeting and/or shoring or other methods. The design engineer accepts no responsibility for the safety of existing
structures.
25. ) ackfil - The contractor shall backfill the pool shell with caution. The plumbing shall not be disturbed. Backfill shall be
accomplished with clean, construction grade fill, free of organic material and shall be placed in 12" thick lifts, each layer shall
be compacted to 95 % maximum dry density per ASTM 0-1557, modified proctor method.
26. fig- To empty pool after construction, for repairs or any other reason, the hydrostatic uplift pressures beneath the
pool must be eliminated to prevent the pool from floating upward. The owner must consult a pool contractor or pool repair
contractor experienced In eliminating uplift pressures.
27. fig- No diving board and no diving Is allowed on any pool less than 8'0" deep and specifically designed for diving. This
pool is not designed for diving unless specifically stated on the site plan.
28. pools & S22with heaters the pool and spa shall be provided with a cover
or other means to reduce heat toss.
29. Pool Enclosure- Residential Pools shall be provided with a barrier compliant w/ F.B.C. 2010 424.2.17 through 424.2.17.1.16
DATE DESCRIPTION BY POOL
a , ®°°°®� FAER-�®�� NAME: MELTZ LOT:
A J��;�a�;`ir 4 J�Q ° • ° ° ° ° ° • ° ° sem 157 N.E. 104th STREET BLOCK:
PLANS ° ° ° G •� s CITY/STATE: MIAMI SHORES, FL,
B 4 4a O�° m STAR -LITE POOLS BUILDERS 33138 BOOK:
C® 10875 N.W. 52nd STREET SUITE !tt
10B#:13.3905-18 PAGE:
® • N O • °
LE
DAVID FAERMAN (P.E. 47646) - - SUNRISE, FL 33351 S BDIVISION!
®•3 22171 WATERSIDE DRIVE (954) 747.3377
SOCA RATON, FL. 33428 ®�0 • wd 1. Faerman,� OUN
PHONE: S61-445-1787 'p ®•• ,� FL. uCEN I�4> ® DATE:07/10/13 MIAMI-DADE SHEET:5OF
®seeA S i � I�� t�9" '°'•
a
Bf&Bio�eS•'"
POOL LOCATION OpLy
I
ROVED 'Ir -�
DMX COUNTY K& -M bepMTM'ff
f'Etmrr
15101 -0 � -a
#W0101AIV
WA
BERM- 07 #0
MAW SHORES VILLAGE
0PROVED DATE
ZONING ice:
b
:: FR4JCTURA
TRUCTURAL
rLECTRIICAL
PLUMBING
.'.rECHANICAL
BLDG.
` UBJECT TO COMPLIAKI CE WiT., i "I'LL rr-n-FRAL
'TATE ANM CC UNTY RULES AND FE,
q I .
m
0
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-206525 Permit Number: BPP -8-13-1939
Inspection Date: January 31, 2014 Permit Type: Pools/Whirlpools/Hot Tubs
Inspector: Dacquisto, David
Inspection Type: Survey Final
Owner: MELTZ, JONATHAN Work Classification: Addition/Alteration
Job Address: 157 NE 104 Street
MIAMI SHORES, FL 33138-2028
Project: <NONE>
Contractor: STAR -LITE POOL BUILDERS
Ri ldinn nanartmanf Cnmmanta
Phone Number
Parcel Number 1121360130750
Phone: (954)747-3377
NEW Swimming POOL
Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed
Failed
Correction
Needed
❑
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
For Inspections please call: (305)762-4949
January 31, 2014 Page 1 of 1
SMWA FL 33126M N.W. 77H STREET, SUITE 202 �1(O'v a Surveyors Inc. 13-0000707-2 ,
TELEPHONE: (308) 2842880 , SURVEY NO
311
FAX: (308) 284-0228
DRAWN BY. LAND SURVEYORS SHEET NO 1 of 2
SURVEY OF LOT 22&23, BLOCK 121, OF MIAMI SHORES SECTION FIVE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK
10, PAGE 47, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA.
PROPERTY ADDRESS: 157 NE 104 ST, MIAMI SHORES, FL 33138
FOR: JONATHAN MELTZ
LOCATION SKETCH Scale 1" = NT.S.
r4 ,
'• sJ so
• F .R f
Ll
6 ti� tI
so
6170, a act
1 C'
(0f
.-4
0- 1 It -31
wmle
LEGEND TYPICAL
A = ARC FNIP. - FEDERAL NATIONAL INSURANCE RAD. = RADIUS OF RADIAL
-OH- OVERHEAD UTILITY LINES
AJC = AIR CONDITIONER PAD PROGRAM RGE. - RANGE
A.E. =ANCHOR EASEMENT IN.&EG. - INGRESS AND EGRESS R.P. - RADIUS POINT
2= C.B.S. -WALL (CBMAJR
Ff13
9
8
i
b
5
•4
3
2
-e~.* W.F. = WOOD FENCE
B.M. = BENCH MARK MIH = MANHOLE SWK = SIDEWALK
B.O.B. = BASIS OF BEARINGS NAP. - NOT A PART OF T = TANGENT
■ 02 = EXISTING ELEVATIONS
C =CALCULATED NGVD =NATIONAL GEODETIC VERTICAL TWP =TOWNSHIP
C.B. = CATCH BASIN DATUM U.E. = UTILITY EASEMENT
C.B.W. = CONCRETE BLOCK WALL N.T.S. - NOT TO SCALE U.P. = UTILITY POLE
SURVEYOR'S NOTES
CH = CHORD O.H.L = OVERHEAD UTILITY LINES W.M. = WATER METER
CH.B. CHORD BEARING O.R.B. = OFFICIAL RECORD BOOK W.R. WOOD ROOF
1) IF SHOWN, BEARINGS ARE REFERRED TO AN ASSUMED
CL -
CL CLEAR O/S OFFSET W.S. =WOOD SHED
MERIDIAN, BY SAID PLAT IN THE DESCRIPTION OF THE
C.L.F... - -
= CHAIN LINK FENCE DVH. OVERHANG
T
1 C'
(0f
.-4
0- 1 It -31
wmle
o
w
1.4
L
ABBREVIATION AND MEANING
LEGEND TYPICAL
A = ARC FNIP. - FEDERAL NATIONAL INSURANCE RAD. = RADIUS OF RADIAL
-OH- OVERHEAD UTILITY LINES
AJC = AIR CONDITIONER PAD PROGRAM RGE. - RANGE
A.E. =ANCHOR EASEMENT IN.&EG. - INGRESS AND EGRESS R.P. - RADIUS POINT
2= C.B.S. -WALL (CBMAJR
Ff13
Q.
1I
to
q
ST
B.C. = BLOCK CORNER L.P. = LIGHT POLE SEC. = SECTION
(6.
o
w
1.4
L
ABBREVIATION AND MEANING
LEGEND TYPICAL
A = ARC FNIP. - FEDERAL NATIONAL INSURANCE RAD. = RADIUS OF RADIAL
-OH- OVERHEAD UTILITY LINES
AJC = AIR CONDITIONER PAD PROGRAM RGE. - RANGE
A.E. =ANCHOR EASEMENT IN.&EG. - INGRESS AND EGRESS R.P. - RADIUS POINT
2= C.B.S. -WALL (CBMAJR
= ALUMINIUM ROOF EASEMENT R.O.E. = ROOF OVERHANG
AIS = ALUMINIUM SHED L.F.E. - LOWEST FLOOR ELEVATION EASEMENT
C.L.F. =CHAIN LINK FENCE
ASPH. = ASPHALT LM.E -LAKE MAINTENANCE EASEMENT RfW = RIGHT-OF-WAY
B.C. = BLOCK CORNER L.P. = LIGHT POLE SEC. = SECTION
-0--0- I.F. =IRON FENCL
B.C.R. = BROWARD COUNTY RECORDS M. = MEASURED DISTANCE S.I.P. = SET IRON PIPE L.B. #6044
-e~.* W.F. = WOOD FENCE
B.M. = BENCH MARK MIH = MANHOLE SWK = SIDEWALK
B.O.B. = BASIS OF BEARINGS NAP. - NOT A PART OF T = TANGENT
■ 02 = EXISTING ELEVATIONS
C =CALCULATED NGVD =NATIONAL GEODETIC VERTICAL TWP =TOWNSHIP
C.B. = CATCH BASIN DATUM U.E. = UTILITY EASEMENT
C.B.W. = CONCRETE BLOCK WALL N.T.S. - NOT TO SCALE U.P. = UTILITY POLE
SURVEYOR'S NOTES
CH = CHORD O.H.L = OVERHEAD UTILITY LINES W.M. = WATER METER
CH.B. CHORD BEARING O.R.B. = OFFICIAL RECORD BOOK W.R. WOOD ROOF
1) IF SHOWN, BEARINGS ARE REFERRED TO AN ASSUMED
CL -
CL CLEAR O/S OFFSET W.S. =WOOD SHED
MERIDIAN, BY SAID PLAT IN THE DESCRIPTION OF THE
C.L.F... - -
= CHAIN LINK FENCE DVH. OVERHANG
PROPERTY. IF NOT, THEN BEARINGS ARE REFERRED TO
= = ANGLE
C.M.E.= CANAL MAINTENANCE P.B. - PLAT BOOK
COUNTY, TOWNSHIP MAPS.
EASEMENTS P.C. POINT OF CURVE =CENTRAL ANGLE
2) THIS IS A SPECIFIC PURPOSE SURVEY.
-
CONC. = CONCRETE P.C.C. POINT OF COMPOUND CURVE
3) THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE
C.P. CONCRETE PORCH PL -PLANTER =CENTER UNE
1:75W FT.
.S. =
CCONCRETE SLAB P.L.S. = PROFESSIONAL LAND 1� =MONUMENT LINE
4) IF SHOWN, ELEVATIONS ARE REFERRED TO
D.E. =DRAINAGE EASEMENT SURVEYOR
MIAM14MDE COUNTY.
D.M.E. - DRAINAGE MAINTENANCE P.O.B.. = POINT OF BEGINNING
EASEMENTS P.O.C.. - POINT OF COMMENCEMENT
SW ELEV. FEET OF NAVA OF 1929.
DRIVE = DRIVEWAY P.P. - POWER POLE
ENCR. = ENCROACHMENT P.P.S.. - POOL PUMP SLAB
E.T.P. = ELECTRIC TRANSFORMER PAD P.R C. - POINT OF REVERSE CURVE
F.F.E. = FINISHED FLOOR ELEVATION PRM - PERMANENT REFERENCE
F.H. - FIRE HYDRANT MONUMENT
F.I.P. = FOUND IRON PIPE PT. = POINT OF TANGENCY
F.I.R. = FOUND IRON ROD PVMT. = PAVEMENT
SURVEYOR'S CERTIFICATION
F.N. = FOUND NAIL PAY - PARKWAY
I HEREBY CERTIFY. THAT THIS "BOUNDARY SURVEY" OF
F.N.D. = FOUND NAIL & DISK R. = RECORD DISTANCE
THE PROPERTY DESCRIBED HEREON, AS RECENTLY
SURVEYED AND DRAWN UNDER MY SUPERVISION,
LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY 1"S! IRV=Y"1
COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS
THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY.
AS SET FORTH BY THE FLORIDA BOARD OF
THE PURPOSE OF THIS SURVEY IS FOR USE IN OBTAINING TITLE INSURANCE AND FINANCING, AND SHOULD NOT BE
PROFESSIONAL LAND SURVEYORS IN CHAPTER 61G17.6,
FLORIDA ADMINISTRATIVE CODE PURSUANT TO 472.027,
USED FOR CONSTRUCTION PURPOSES.
FLORIDA STATUTES.
- EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY,
AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS
OR EASEMENTS OF RECORD, AND LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY.
BOUNDARY SURVEY MEANS A DRAWING AND / OR A GRAPHIC
A/
REPRESENTATION OF THE SURVEY WORK PERFORMED IN
THE FIELD, COULD
BE DRAWN AT A SHOWN SCALE AND / OR NOT TO SCALE.
—
EASEMENTS AS SHOWN ARE PER PLAT BOOK UNLESS OTHERWISE SHOWN.
BY. 0�-� Z
- THE TERM "ENCROACHMENT' MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS.
- ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS AND SETBACKS, AND THEY WILL BE RESPONSIBLE
- FOR SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THEIR APPROVAL FOR AUTHORIZATION TO
AUTHORITIES IN NEW CONSTRUCTIONS, UNLESS OTHERWISE NOTED. THIS FIRM HAS NOT ATTEMPTED TO LOCATE
PROFESSIONAL LAND SURVEYOR
FOOTING AND/OR FOUNDATIONS.
NO. 2534
FENCE OWNERSHIP NOT DETERMINED.
STATE OF FLORIDA (VALID COPIES OF THIS SURVEY WILL
- THIS PLAN OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED.
BEAR THE EMBOSSED; SEAL. OF THE ATTESTING LAND
- HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY.
SURVEYOR).
- THE SURVEYOR MAKES NO GUARANTEES AS TO THE ACCURACY OF THE INFORMATION BELOW. THE LOCAL F.E.MA
- AGENT SHOULD BE CONTACTED FOR VERIFICATION. THE FNIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED
REVISED ON:
LAND TO BE SITUATED IN ZONE: X COMMUNITY/PANEL/SUFFIX: 120680 0302 L DATE OF FIRM: 081111=08
BASE FLOOD ELEVATION: WA
REVISED ON:
CERTIFIED TO: JONATHAN MELTZ
N
µ6�...184
�•'' ,'fIF/Q''
,'•
0p
#09'4 - q•9
ye r N0 2834
e
STATE OF
<,IMO
Sli
SURVEYOR'S SEAL I
S
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
inspection Number: INSP-206525 Permit Number: BPP -8-13-1939
Inspection Date: January 31, 2014 Permit Type: Pools/Whirlpools/Hot Tubs
Inspector: Dacquisto, David
Inspection Type: Survey Final
Owner: MELTZ, JONATHAN Work Classification: Addition/Alteration
Job Address: 157 NE 104 Street
MIAMI SHORES, FL 33138-2028
Phone Number
Parcel Number 1121360130750
Project: <NONE>
Contractor: STAR -LITE POOL BUILDERS Phone: (954)747-3377
Buildina Department Comments
NEW Swimming POOL
Infractlo Passed Comments
INSPECTOR COMMENTS False
Passed
Inspector Comments
f � � � ,-.� � ,� � { t d
Failed //y
Correction
Needed
❑
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
L/9y
For Inspections please call: (305)762-4949
January 31, 2014 Page 1 of 1
7TH
UU N.W. 331 ' SUITE 202 �l ova Surveyors Inc. 13-006076 .
MIAMI, FL 33128 SURVEY NO - e
TELEPHONE ( 2880 ,,
FAX: 1308) 229
DRAWN BY: LAND SURVEYORS SHEET NO 1 OF 2
SURVEY OF LOT 22823, BLOCK 121, OF MIAMI SHORES SECTION FIVE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK
10, PAGE 47, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA.
PROPERTY ADDRESS: 157 NE 104 ST, MIAMI SHORES, FL 33138
FOR: JONATHAN MELTZ
LOCATION SKETCH Scale 1" = NT.S.
_ .•� A
4 1W, —N
a�
SJ so
Vol
X15 16 %I $I
t sd
ABBREVIATIONAND MEANING
A = ARC
FNIP. = FEDERAL NATIONAL INSURANCE
RAD. - RADIUS OF RADIAL
A1C = AIR CONDITIONER PAD
PROGRAM
RGE. = RANGE
A.E. = ANCHOR EASEMENT
9$
13
7
r
b
5
4:
3
2L
1
L.M.E. = LAKE MAINTENANCE EASEMENT
RAW = RIGHT-OF-WAY
B.C. = BLOCK CORNER
L.P. = LIGHT POLE
SEC. = SECTION
B.C.R.= BROWARD COUNTY RECORDS
M. = MEASURED DISTANCE
S.I.P. = SET IRON PIPE L.B. #6044
B.M. = BENCH MARK
MAH - MANHOLE
SWK = SIDEWALK
4k
N.A.P. = NOT APART OF
T = TANGENT
C = CALCULATED
NGVD = NATIONAL GEODETIC VERTICAL
TWP - TOWNSHIP
C.B. = CATCH BASIN
ABBREVIATIONAND MEANING
A = ARC
FNIP. = FEDERAL NATIONAL INSURANCE
RAD. - RADIUS OF RADIAL
A1C = AIR CONDITIONER PAD
PROGRAM
RGE. = RANGE
A.E. = ANCHOR EASEMENT
N 14
13
It
it
10
i
>
T
A-
ABBREVIATIONAND MEANING
A = ARC
FNIP. = FEDERAL NATIONAL INSURANCE
RAD. - RADIUS OF RADIAL
A1C = AIR CONDITIONER PAD
PROGRAM
RGE. = RANGE
A.E. = ANCHOR EASEMENT
IN.BEG. = INGRESS AND EGRESS
R.P. - RADIUS POINT
AIR = ALUMINIUM ROOF
EASEMENT
R.O.E. - ROOF OVERHANG
AIS - ALUMINIUM SHED
L.F.E. - LOWEST FLOOR ELEVATION
EASEMENT
ASPH. = ASPHALT
L.M.E. = LAKE MAINTENANCE EASEMENT
RAW = RIGHT-OF-WAY
B.C. = BLOCK CORNER
L.P. = LIGHT POLE
SEC. = SECTION
B.C.R.= BROWARD COUNTY RECORDS
M. = MEASURED DISTANCE
S.I.P. = SET IRON PIPE L.B. #6044
B.M. = BENCH MARK
MAH - MANHOLE
SWK = SIDEWALK
B.O.B. = BASIS OF BEARINGS
N.A.P. = NOT APART OF
T = TANGENT
C = CALCULATED
NGVD = NATIONAL GEODETIC VERTICAL
TWP - TOWNSHIP
C.B. = CATCH BASIN
DATUM
U.E. = UTILITY EASEMENT
C.B.W. = CONCRETE BLOCK WALL
N.T.S. = NOT TO SCALE
U.P. = UTILITY POLE
CH = CHORD
O.H.L. = OVERHEAD UTILITY LINES
W.M. = WATER METER
CH.B. = CHORD BEARING
O.R.B. = OFFICIAL RECORD BOOK
W.R. = WOOD ROOF
CL= CLEAR
O/S = OFFSET
W.S. = WOOD SHED
C.L.F. = CHAIN LINK FENCE
OVH. = OVERHANG
C.M.E. = CANAL MAINTENANCE
P.B. = PLAT BOOK
c� a ANGLE
EASEMENTS
P.C. = POINT OF CURVE
A =CENTRAL ANGLE
CONC. = CONCRETE
P.C.C. = POINT OF COMPOUND CURVE
C.P. = CONCRETE PORCH
PL. = PLANTER
q a CENTER LINE
C.S. = CONCRETE SLAB
P.L.S. = PROFESSIONAL LAND
-MONUMENT LINE
D.E. = DRAINAGE EASEMENT
SURVEYOR
D.M.E. = DRAINAGE MAINTENANCE
P.O.B.. = POINT OF BEGINNING
EASEMENTS
P.O.C.. = POINT OF COMMENCEMENT
DRIVE = DRIVEWAY
P.P. - POWER POLE
ENCR =ENCROACHMENT
P.P.S.. = POOL PUMP SLAB
E.T.P. = ELECTRIC TRANSFORMER PAD
P.R.C. = POINT OF REVERSE CURVE
F.F.E. - FINISHED FLOOR ELEVATION
PRM - PERMANENT REFERENCE
F.H. = FIRE HYDRANT
MONUMENT
F.I.P. = FOUND IRON PIPE
PT. = POINT OF TANGENCY
F.1 R. = FOUND IRON ROD
PVMT. = PAVEMENT
F.N. = FOUND NAIL
PWY = PARKWAY
F.N.D. = FOUND NAIL & DISK
LEGAL NOTES TO AC^OMPANr SKETCu nc
R - RECORD DISTANCE
¢� �wvcv m¢i twt
- THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY.
- THE PURPOSE OF THIS SURVEY IS FOR USE IN OBTAINING TITLE INSURANCE AND FINANCING, AND SHOULD NOT BE
USED FOR CONSTRUCTION PURPOSES.
- EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY,
AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS
OR EASEMENTS OF RECORD, AND LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY.
BOUNDARY SURVEY MEANS A DRAWING AND i OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN
- THE FIELD, COULD BE DRAWN AT A SHOWN SCALE AND / OR NOT TO SCALE.
EASEMENTS AS SHOWN ARE PER PLAT BOOK, UNLESS OTHERWISE SHOWN.
- THE TERM "ENCROACHMENT' MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS.
- ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS AND SETBACKS, AND THEY WILL BE RESPONSIBLE
- FOR SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THEIR APPROVAL FOR AUTHORIZATION TO
AUTHORITIES IN NEW CONSTRUCTIONS, UNLESS OTHERWISE NOTED. THIS FIRM HAS NOT ATTEMPTED TO LOCATE
FOOTING AND/OR FOUNDATIONS.
FENCE OWNERSHIP NOT DETERMINED.
- THIS PLAN OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED.
- HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY.
- THE SURVEYOR MAKES NO GUARANTEES AS TO THE ACCURACY OF THE INFORMATION BELOW. THE LOCAL F.E M.A.
- AGENT SHOULD BE CONTACTED FOR VERIFICATION. THE FNIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED
LAND TO BE SITUATED IN ZONE: X COMMUNITYAPANEUSUFFDC 120880 0302 L DATE OF FIRM: 0911112009
BASE FLOOD ELEVATION: NIA.
LEGEND TYPICAL
--ON- OVERHEAD UTILITY LINES
as C.B.S. -WALL (CBVA
-x-x C.L.F. - CHAIN LINK FENCE
-O-O- I.F. - IRON FENCE
ri-rr W.F. a WOOD FENCE
• am - EXISTING ELEVATIONS
S RV
1) IF SHOWN, BEARINGS ARE REFERRED TO AN ASSUMED
MERIDIAN, BY SAID PLAT IN THE DESCRIPTION OF THE
PROPERTY. IF NOT, THEN BEARINGS ARE REFERRED TO
COUNTY, TOWNSHIP MAPS.
2) THIS IS A SPECIFIC PURPOSE SURVEY.
3) THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE
1:7500 FT.
4) IF SHOWN, ELEVATIONS ARE REFERRED TO
MIAMI -DARE COUNTY.
BW ELEV. FEET OF N.G.V.D. OF 1929.
RVEYOR'S CERTIFICATION
I HEREBY CERTIFY. THAT THIS "BOUNDARY SURVEY" OF
THE PROPERTY DESCRIBED HEREON, AS RECENTLY
SURVEYED AND DRAWN UNDER MY SUPERVISION,
COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS
AS SET FORTH BY THE FLORIDA BOARD OF
PROFESSIONAL LAND SURVEYORS IN CHAPTER S1 G17-6,
FLORIDA ADMINISTRATIVE CODE PURSUANT TO 472.027,
FLORIDA STATUTES.
PROFESSIONAL LAND SURVEYOR NO. 2534
STATE OF FLORIDA (VAUD COPIES OF THIS SURVEY WILL
BEAR THE EMBOSSED SEAL OF THE ATTESTING LAND
SURVEYOR).
REVISED ON:
REVISED ON:
CERTIFIED TO: JONATHAN MELTZ
N
E.. Le.'aP
IFIC,� :'P -
a : NO. 2834 ; ;
•'., STATE OF
�'No 8UR40
SURVEYOR'S SEAL
3