Loading...
RF-14-4Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 nspection Number: INSP-206985 Permit Number: RF -1-14-4 Inspection Date: February 21, 2014 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: JONES VAN HOOSEAR, NANCY Work Classification: Repair Roof Job Address: 117 NW 100 Terrace Miami Shores, FL Project: <NONE> Phone Number 3057573185 Parcel Number 1131010220230 Contractor: ENVIROTECH ROOFING & CONSTRUCTION INC Phone: (305)207-4993 Buildina Department Comments REPAIR TILE LEAK Infractio Passed Comments INSPECTOR COMMENTS True Inspector Comments Passed i CREATED AS REINSPECTION FOR INSP-205251. Need revision. Roof ok for final Failed El Correction Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. For Inspections please call: (305)762-4949 February 21, 2014 Page 1 of 1 Miami Shores Village c Building Department D FEB t 4 2014 90050 N.E.2nd Avenue, Miami Shotes, Florida 33138 BY---,/O� Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 JOB ADDRESS: _ I I'3 P 06 �� ( City: 1Vrami Shotes County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Address: 1 I .} N LA..,' t CLO City: Lw1 lJ�• e ( Q State: e - f L Zi 1 � p: Tenant/Lessee Name: Phone* Email: CONTRACTOR: Company Name: z 1 0 -'LC -L9 '4.1z� 4 el �' Phone#: �/ �G ° 3) q ^ w L Address: ) 3 � a l i C..s Q1 « City: iii i State: Qualifier Name: State Certification or Registration #: C C.\ 1 5.4 r( K J;3 Certficate of Competency #: Contact Phone#: l Address: DESIGNER: Ambitect/Engincer. Iv 14, Value of Work for this Permit: $ Type of Work: OAddition DAlteration Description of Work: "-R-CIA S i ai I Color thru tile: 971 far' Footage of�Vor. r►-� z 147m, zip: 33>? -T -3 7-s /4--.1®(4G Submittal Fee $ Permit Fee $ CCF $, CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Oonding;Company's Name,(if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws 'regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a1einspectiondfee will be charged. O ne or Agent The foregom* instrument was acknowWdged before me this day or gr t. 20/;__5;1_9 by who is o y kno me or who has aced As identification and who did take an oath. NOTARY PUBL •`'� "" �''�• NATALY FERNANDEZ ,ms's Notary Public -State of Flot1M Sign: a My Comm. Expires Aug 9, 20116 Prim: My Commission Contractor The foregoing instrument was acknowledged before me this L;2 JP - day o��y 0 � by e � JP z Pl�-- who 'to me or who has produced as identification and who did take an oath. Structural Review (Revised 3/12i2012)(Revlsed 07/10/07)(Revised 0611(112009)(Revised 3/15/09) NOTARY Sign: - Print My Commission Expires: ELISA I POUSO Notary Public - State of Florida My Comm. Expires Oct 4. 2016 BOndPO Through Nahonat Zoning Clerk Momma gadding Cade 201P ofmit ppilca"*n "onn wt Vetod:.v N.Mcme tone Unf*fm 4D gyIV yetpom,,.... Number. Mae* of AC"Plm"' Iicabte (From RAS12T or C��ulatio�i 1 t �nlntum Oos19u end Pressures, k APP _ —I _Q -*k P3: of oft d St �O p,�t 7jip0• '�� •�-2.10 �gtop0: sutallon: ��� astet+Or'�YPO �O Vince°"� dheatve TYPO � � • 91 ...�-�, Cap g SS ooh covoinA: ypo & $ISO Cf1p • hP _ `_ ` 9e � 1 BY. DATE ..-w ZONING DEF F BLDG DEPT SUBJECT fO CCNIPI.If NCE WI FH STATE ANO C( UNv �'f rilL_S--AT10NS A 01 • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (.Tile Calculations) For Moment based file systems, choose either Method I or 2. Compare the values for Mr with the values from Mt. If the Mt values are greater than or equal to the Mr values, for each area of the roof, then the file attachment method is acceptable. Method I "Moment Based Tile Calculations Per RAS 127" (Pl:_+�,�g Mg•.q P'°duct Approval M ft� 11w� Mg:�d++p� hlrz�1` Produn Approval Mtn (P3: L•� � Mg: �._1_ Z eruct Appraal Mr�7 •� Method 2 "Simplified Tile Calculations Per Table Below" *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. ForUpliftbased file systems use Method 3. Compared the values for F with the values for Fr. Ir the F values are greater than or equal to the Fr values, for each area of the roof then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" .* (PI: x L = x w: _ _) - W x cos o • = Frt -- Product Approval F (Pz: x L = x w _ _) - W x cos 8 = Frz Product Approval F (P3: x L = x w: - W: x cos 8 _•...— = Fr3 ---•-• Product Approval F Where to O tain I f mation Descripflon -- -ftmbol Where to find Design Pressure P1ornor P3 RAS 127 Table Iorbyanengineering analysis Prepared byPEba=WonASCE7 2010 Mean Roof Height Mr required Moment Resistance* lob Site • Roof Slope Wean Roof Height's Roof slope ,� 15' 20' 25' 30• 40• 2:12 34.4 36.5 38.2 39.7 42.2 3:12 322 34A 36.0 37A 39.8 412 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6_ .' 32.8 34.9 6:12 26.4 28.0 _29.4 30.5 32A 7:12 24.4 25.9 27.1 282 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. ForUpliftbased file systems use Method 3. Compared the values for F with the values for Fr. Ir the F values are greater than or equal to the Fr values, for each area of the roof then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" .* (PI: x L = x w: _ _) - W x cos o • = Frt -- Product Approval F (Pz: x L = x w _ _) - W x cos 8 = Frz Product Approval F (P3: x L = x w: - W: x cos 8 _•...— = Fr3 ---•-• Product Approval F Where to O tain I f mation Descripflon -- -ftmbol Where to find Design Pressure P1ornor P3 RAS 127 Table Iorbyanengineering analysis Prepared byPEba=WonASCE7 2010 Mean Roof Height H lob Site • Roof Slope 6 lob Site _ Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity M Product Approval Attactunent Resistance Mf Product Approval Required Moment Resistance M Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval 'lite Dimensions = L length W = width Product Approval _ pplication All calculations must be submitted to the building official at the time of permit application- 2010 FLORIDA BUILDING CODE — BUILDING 115.37 MIAMI-DARE COUNTY H"mmPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eoy/economy Polyglass USA Incl' 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. LNOA No.: 12-0713.01 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, AFP underlayment 32'10" x 3'33/$" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self -adhering, glass- underlayment 65' x 3'33/&" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof Manufacturing Location tile underlayment. #1&#2 Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10" x 3'3 3/s" ASTM D 1970 glass-fiber/polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a tile roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass- Mamfacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 65'8" x 3933/8" waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick IR -Xe Roll: TAS 103 and A fine granular/sand top surface self -adhering, underlayment 65' x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, AFP underlayment 32'10" x 3'33/$" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self -adhering, glass- underlayment 65' x 3'33/&" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof Manufacturing Location tile underlayment. #1&#2 Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10" x 3'3 3/s" ASTM D 1970 glass-fiber/polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a tile roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass- Mamfacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self -adhering, polyester Manufacturing Location 65'8" x 3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed #2 60 mils thick as a a roof tile underlayment. MANUFACTURING PLANTS: 1.Hazelton, PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Aaency Test Identifier Test Name/Report Date Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08 -R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-1 TAS 103 & TAS 110 08/06/12 P40390.08.12-2 ASTM D 1623 08/07/12 P40390.10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PRI01 I I I ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23D8A TAS 103/ASTM D4798 & G155 02/18/10 NOA No.: 12-0713.02 MADE � Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self -adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3-'/z" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 4 of 8 GENERAL LonTATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure rimes; not to exceed the preceeding maximum time limitations. Ex sure Limitations (days) MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven, FL. 180 180 180 180 180 180 180 90 Hazelton, PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. & In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Polystick TU Plus, TU P, Tile Max Pro Flat Tile Prohibited without 5:12 No limitation No limitation battens Profiled Tile Prohibited without Prohibited No limitation No limitation battens The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. CL 0 W N r m 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, Til Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMI-DADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum I" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7712" or greater. It is suggested that on pitch/slopes in excess of 6'/a"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 8 Miami Shores Village I ''"'"w BuildingDepartment6y'- �A" o 2014 p 10050 NY -2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING FBC 20 Permit No. Master Permit No L ROOFING JOB ADDRESS: _ I 1 i P4._> /®o --rL'r - City. Nami shores County: Miami Dade Zip. Folio/ParceW Is the Building Historically Designated: Yes NO OWNER: Name (Fee Simple Zone: Tenant/Lessee Name: Phone#: Email: 4. CONTRACTOR: Company Name:�T� T� �Pho> e, Address: N�iMD \ �,1����' City: N_&IY i State:- 7ip:331�1 Qualifier "30T _tCns State Certification or Registration #: C.—L�',"NtZn�� Certificate of Competency#: Contact Phone#: Email Address:��"?�� �l DESIGNER: Awbitect/Engineer. Phone#: Value of Work for this Permit: $ -Q Square/Linear Footage of Work: Type of Work: DAddition DAheration ONew W 2erR air/Replace pDemolition Description of Work: —� �.:Y i hN Color Jthru dk: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ TraiaingWAncation Fee $ Technology Fee $ Double Fee $ Stractarai Review $ TOTAL FEE NOW DUE $ 7 Z-) r Bonding Company's Name (if applicable) Bonding Company's Address 11 City State zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a r inspection fee will be charged. SignaturSignature Agent Contractor The fore oing i tTrument was acknowledged before me this i The fore g instrument was acknowledged before me this /V day of �` 20 J, by . day of )VI 20 a by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: , ELISA I POUSO Sign: :'? n My Comm. Expires Oct 4, 2016 Print:EE 20?519 =v My Commission Bonded Through National Notary Assn. APPROVED BY Plans Examiner Print: MyC as identification and who did take an oath. PUBLIC: ELISA I POUSO Notary Public - State of Florida Commission # EE Zoning Structural Review Clerk (Revised 3n2/2012)(Revised 07/1 0/07)(Revised 06/10 M)(Revised 3n 5/09) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: kc-�Ac clx Property Add Roofing Permit Number: 0-i L'i ---e C ('. Dear Building Official: I S� t�t� certify that I am not required to retrofit the roof to wall connections of my Mst 'because: valuation for the structure for u ose of ad valorem taxation is less than 300 000.00. PIpurpose $ ease attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) o2lfte.& -.-, AIA17ey 14/1 Signa Print Name State of Florida County of Dade The undersigned, being the first duly swom, Sworn to and subscribed before me this Notary Public, Sate of Florida at Large t`,pY PVA �{ ELISA I POUSO �6- �pylpfa�y Puhtin _ State s ReFid_ • My ��Notary ct 4, 2016 207519 Assn. above property mentioned. • When the just valuation of the structure for purpose of ad valorem taxation Is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 621009 ;01 v Code 2010 . ne Zone Unibnn Pe�� •1ILIIIJ c I ..�ixrtx r. ■ �M MMMMM'�ltw xM.NR�ritY%111 .Isal[II�a11t1 1• rt at a a lea RM MMURMrIRt>>i��M� RY lk%0xr R{f{ti 1[MM.00 tulltrllR{+• �ltitrt !�[ryRRMft![t(�wRMM�� r.ft71iM 1f��IM��R �rrr<.r•rrarartilwrlrlsM[I % MT•i.K14 R11 MtRM>NRi 1)lNRIiRKRIt MMI[ t .+ �:�:r r.>nn ••;¢cs ��R� ° A� jR1.• ■■■■�� * C[Rr1t�f11 RM fMRMMM11Mr11(YjI1 MwM� a. MARS ■^ ��aa Miff R!M II R#1•Y r.'�R��;��"CC�C�����r_��+ IwoPiR14Mw..7'Pw�lRiiiw M ,rral+�r�ar_ `i711EMX f IN R. �� ',[�/fll[t1� 1111 �w-..�,.�..� �--" �^ ryj■rt[11)k*�!/ �MI1i111at Al.,►���� II� r �I■■ h r JI 1aR,1x>IrMlf r )ff1i111frt11�d��*7[Mi1�4 iK�. ToKia "'�1 1, iR�N 1■ M M� t MMIM } 11 • it IMtll 10 I I y1,1i�ryr p__1om�sa :���.Grrt M><1R1 !A 1e9`I 6 �w !1R[RxMR� f�►M Mil .. ,,,. ��� NIS %MM "al, i.. Vi�� M �jx M� M rl+,w.�.". ���+ i�iily� y��� I . i � ,�x ►�t fRs►M .��4.�� WxF411l�k'�i9�i1 �1% 11 1� i !fes 11R► ..L.,. nlool�!PH.. li 411► __,W.r V4, ►KRa..r,. M�MMixxM�+ ■� ii%�'t;��iww+ ' y�� r x�rIN ,"'�y�i 11i[Rtf r''� M � li 1111R><�MY{tfR1[ Yf� .'f'M�M�#AM�Mt1 � �� 1►>r ,?}..��.,�i1M{�M r v���.•!! ioiillY11Nr Sl q+' 1►r �I( lY �� }�Mr�1iy1.,��1r��M� ��N����1xIYt1 r, �►�d�k�C"i����i����� � ��� * �����ii[1#1Kx��i �r1�i Ifl� �YY�wewTP�11°Se:..t r M L� R 11 0. Flom Building Code 2010 Edition High Velocity HuMenne Zone Uniform Pormit AppliccaMon Fonn §222MALMAM-812RIdBW 2 INO R�1'Syslem ManufactuM..Mi. NOW ofAccopUmm Number.--=.9�L'�1•Q1� ljb tntum Destgn Wind Pressures, N Applicable (From RAS 127 or Cakxdations): P2:" PS: Meodmim Oos[gn Pnmure Mom Ow HOA S c: [ kd" of #its► attachntenD_ D04* Ile: Ridge vmfttlon? UM Roof Heigtt'b_-XIL--, after TM a spacing: CUP Type b Ske DIV dge: WN q v3X A ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High -Velocity Hurricane Zone UnNorm Permit Application Foran. Section E ile Calculations) For M=mtbased filesystems, choose either Method 1 or 2. Compare the values for Mr with the values from Mt. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable. . s ` Method 1 "Moment Based Tile Calculations Per RAS 127" (P,.- )L-:�Ra♦`� y�1- Mg 5 = ?A4, M-- Product Approval M,146 (PV X-- ft =.3 - Mg J 1- K2% \ Product Approval MfL-V:ty� (P3: x 7l• - Mg:�� K3a,, Product Approval Mf-»,� Method 2'Simplified Tile Calculations Per Table Below" RmAred Moment of Resistance (Mr) From T.W. Product Approval Mr � *Must be used -do conjunction with a list of moment based file systems endorsed by the Broward County Board of Rules and Appeals. ForUpfift based file systems use Method 3. Compared the values for F with the values for Fr If the F values are greater than or equal to the Fr values, for each ata of the root then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (PI: X L =,_ X w: = . ) - W: X Cos B ' = Frt __•„ Product Approval V (P2: X L = X W: a _ , - W; x cos,6 = Fr2 Product Approval F' (P3: x L = x w: = _ , - W: x cos B . _ = Fra Product Approval F' Where to Ob ain Information Mr required Moment Resistance* Umbol Where to find Meant Roof Height -> Roof slope � 15'20' RAS 127Tabklorbyanmginecringanalysis prepared byPEbasedonASCE7 25' 30' 4W 2:12 34.4 lob Site 36.5 38.2 39.7 42.2 3:12 322 Product Approval, 34.4 36.0 37.4 39.8 4:12 30.4 Calculated 32.2 33.8 35.1 37.3 5:12 28.4 Calculated 30.1 31.6 32.8 34.9 6:12 26.4 Product Approval 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used -do conjunction with a list of moment based file systems endorsed by the Broward County Board of Rules and Appeals. ForUpfift based file systems use Method 3. Compared the values for F with the values for Fr If the F values are greater than or equal to the Fr values, for each ata of the root then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (PI: X L =,_ X w: = . ) - W: X Cos B ' = Frt __•„ Product Approval V (P2: X L = X W: a _ , - W; x cos,6 = Fr2 Product Approval F' (P3: x L = x w: = _ , - W: x cos B . _ = Fra Product Approval F' Where to Ob ain Information DescripMon Umbol Where to find Design Passims PI or P2 or P3 RAS 127Tabklorbyanmginecringanalysis prepared byPEbasedonASCE7 Mean Roof Height H lob Site Roof Slope B lob Site Aerodynamic Multiplier d Product Approval Restoring Moment due to Gravity M Product Approval, A#wJ mrom Resistance Mf Product Approval Required Moment Resistance M Calculated bliiaimum Altaehment Resit F' Product Approval Requited UpliftResistam Fr Calculated Average Ttle Weigbt W Product Approval Tile Dirmensiow W - Length Product Approval AU calculations must be submitted to the building official at the time of permit application. 2010 FLORIDA BUILDING CODE - BUILDING a .15.37 M"s OWNER°S NOTIFICATION FORM SECTION 1524 HIGH VELOCITY HURRICANE ZONE—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initials in the designed space indicates that the item has been explained. ED1. Aesthetics-worlonanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). ® 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants and adjacent units of roofing work to be performed. wo4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining its appearance. FYI 5. Ponding water. The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Fy6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of ff r 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some abilityto vent natural airflow through the interior of the g structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate the attic venting, shall not be required. Owner's/Agents Signature: Date: [21/ / / Contractor's Signature: Permit Number: Property Address: 12301-197 12109 r KIAH MIAMI-DADE COUNTY is PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DMSION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOM www.miamidade.Qov/vera Boral Roofing LLC.' 7575 Irvine Center Drive, Suite 100 Irvine, CA. 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Vanguard Roll Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been fled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0308.06 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0904.06 Expiration Date: 12/16/17, Approval Date: 12/06/12 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a system using Vanguard Roll Concrete Roof Tile, as manufactured Boral Roofing LLC in Pompano Beach, FL., and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Vanguard Roll Concrete L = 16-'/2" Roof Tile W = 13" %2" thick Test Specifications Product Description TAS 112 Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 w = varies varying thickness 2. 1 PRODUCT DESCRIPTION 1. Pompano Beach, FL. 2.2 SUBMTMD EVIDENCE: Test Agency Test Identifier Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies 7161-03 Appendix III 7161-03 Appendix lI P0402 94-060B 94-084 P0631-01 Letter Dated Aug. 1, 1994 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Date Static Uplift Testing Dec. 1991 PA 102 & PA 102(A) Wind Tunnel Testing Dec. 1991 PA 108 (Nail -On) Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Static Uplift Testing March, 1994 PA 101 (Adhesive Set) Static Uplift Testing May 1994 PA 101 (Mortar Set) Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) NOA No.: 12-0904.06 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 2 of 6 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC -7611 PA 100 The Center for Applied 25-7183-1 Static Uplift Testing Feb. 1995 Engineering, Inc. PA 102 (2 Quik -Drive Screws, Direct Deck) The Center for Applied 25-7183-2 Static Uplift Testing Feb. 1995 Engineering, Inc. PA 102 (2 Quik -Drive Screws, Battens) The Center for Applied 25-7214-2 Static Uplift Testing March, 1995 Engineering, Inc. 25-7214-6 PA 102 (1 Quik -Drive Screw, Direct Deck) (1 Quik -Drive Screw, Battens) Celotex Corporation 528454-2-1 Static Uplift Testing Sep. 1998 Testing Services 520109-2 PA 101 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier August 2007 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers October 2007 Walker Engineering, Inc. Evaluation Calculations Two Patty Adhesive Set System April 1999 Nutting Engineering TAS -112 13343.1 June 2007 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 12-0904.06 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 3 of 6 4. INSTALLATION 4.1 Vanguard Roll Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Welght W (Ibf) Length -I (ft) Width -w (ft) 1 Vanguard Roll Roof Tile 9.2 1.38 1.08 Table 2: Aerodynamic Multipliers -.% (ft) Tile Profile X (ft) Batten Application (ft ) Direct Deck Application ,Vanguard Roll Roof Tile 0.266 0.289 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 3":12" 4":12" 6":12" 6":12" 7':12" or greater Vanguard Roll Roof Tile Battens Direct Deck Battens I Direct Deck Battens Direct I Deck Battens Direct Deck Battens Direct Deck Battens IDirect Deck 1 5.30 6.03 1 5.24 5.97- 1 5.16 1 5.87 5.05 5.75 4.92 5.60 4.78 5.44 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19132" plywood) Battens Vanguard Roll Roof Tile 2-10d Ring Shank Nails 27.8 37.4 28.8 1-10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 48 Screw 25.8 25.8 22.9 2 48 Screws 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Naiis Eave Clip) 31.9 31.9 32.2 NOA No.: 12-0904.06 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 4 of 6 Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Vanguard Roll Roof Tile Adhesive 26.1 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 11.4 grams. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Vanguard Roll Roof Tile 3M 2 -Component Foam Roof Tile Adhesive AH -160 86.61 3M 2 -Component Foam Roof Tile Adhesive AH -160 45.5 3 Large paddy placement of 54 rams of W""2 -Component Foam Roof Tile Adhesive AH -160. 4 Medium paddy placement of 24 rams of Wm 2 -Component Foam Roof Tile Adhesive AH -160. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Vanguard Roll Roof Tile Mortar Set 20.60 5 Tile-Tite Roof Tile Mortar. 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". VANGUARD ROLL BORAL ROOFING LLC VANGUARD ROLL ROOF TILE (POMPANO BEACH, FL.) (LOCATED ON UNDERSIDE OF TILE) NOA No.: 12-0904.06 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 5 of 6 6. BUILDING PERmrr REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS y �� VANGUARD ROLL ROOF TILE (POMPANO BEACH, FL.) END OF THIS ACCEPTANCE NOA No.: 12-0904.06 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 6 of 6 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material falls to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0228.19 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2 -Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH - 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof file adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6lbs ./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Fe Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @I 580F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F _W 2 F'= MS NOA No.: 12-0228.18 MtAMNflADE COUNTY Expiration Date: 05/10/17 APPROVED Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF 1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17/side on cap and 34/ an N/A Flat, Low, Hig4 Profiles #224 N/A Flat, Low, High Profiles #3 8 NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 4 of 7 LABELING: All 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. WELDING PERMIT REQuiREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY F�da EBYe COUBa adr: Keep ad MW8 approa. 4(e. up hom weepholes Nag #m9h plastic cement Paddy(BeTile) Undgwflamt 101L - 21 .. = - e e Eeve COWU Fasd8 Bleepdofe EBVe cause enly: Eave dwA P Ddp� 4 pfrom NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nag through plasliccement Paddy Pened TUB) Nag through pladc cement Paddy (Ben" T119) Undedayment 0 Underlayment 1 71n. 7r IM2 In. Em Cm Fascla Fesda %Weephols Eave Covise closure "NDdp edge Ea" Closure NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 q ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy Nall through pladc cement (between Go) 0 Underlayment Paddy (under 919) Nall through plastic cement loll ,ftl'ln. 31 Single paddy END OF THIS ACCEPTANCE Single paddy undergo Single paddy between Me 2 In. x 7 In. mdum size paddy we course only ,,-" Fascla % Weephole M closure Drip edge NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 Single paddy x 3 In. 44 R43-1 n. X 3 1 n. r3 undo Me r xini x3 rL Single paddy on 2 In. 4 In. 4 In, 21 4 In. 2 In. st Single under- 0 paddy on under - I nt layment H�- Single M I paddy gle pa Eave cum on top of file Single paddy In. X 7 In. Medium Wave coume me % on top of Ole she paddy em Fascia course only I Nall through plastic cement loll ,ftl'ln. 31 Single paddy END OF THIS ACCEPTANCE Single paddy undergo Single paddy between Me 2 In. x 7 In. mdum size paddy we course only ,,-" Fascla % Weephole M closure Drip edge NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7