RF-14-380Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit No. FEB $ 8 2014 Master Permit No.M I �A Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): h 11'1 � � Phone#: 305 3,'M °-3q ( 9 Address: ' 0 6!5 IVE q rj City: M I C 1 ky res State: zip: 33 I �' Tenant/Lessee Name: Email: JOB ADDRESS: City: Mi. I Folio/Parcel#: l - 0 b5 NE 11 f1+K _ °+ Is the Building Historically Designated: Yes County: Miami Dade zip: NO `0e Flood Zone: CONTRACTOR: Company Name: L �CXLLI l�Cati✓�-ICK lRoo-f n o 1_ 0 Phone#: 3®� �5—D Q' Address: 3 2 q' pr _S, k4 117 q�e-r - City: State: Fl- Zip: A30A9 j Qualifier Name: & WP�L-� %{ /-! Phone#: -01-q/ nl 1 State Certification or Registration #: C GO �" I a� Certificate of com2etency #: 6 AS 0®®®' Contact Phone#: (W -6t1 HISW) Email Address: rJ 1A_ DESIGNER: Architect/Engineer: Value of Work for this Permit: $ 00 2100 Type of Work: OAddition __ +UAAlteration 0 ODemolition Description of Work: �r 0 f e-)( I s 1 V ( a-ce w h OL Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City - - - ,'_ State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a y of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject o a-- chment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection hich occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not b ro d and a reinspection fee will be charged. Signature Signature Owner or Agent The foregoing instrument was acknowledged before me this -7 day of re,6 , 20 �Y, by , who is personally known to me or who has produced I Z ' L, As identification and who did take an oath. NOTARY PUBLIC: My Commission Expires: APPROVED BY (Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) rdft-lodlr Contractor The foregoinginstrument was acknowledged before me this day of S , 20 a, by V-Oi, who is pe oeho has produced as identification and who did take an oath. C r Plans Examiner Structural Review NOTARY PUBLIC: �"0-\ \� "' Sign: Print: _ ° att, al My Commission Expires: = �pEti�1305g:Nrs OF ge Zoning Clerk Return to: CHRISTOPHER P. KELLEY, P.A. 11098 Biscayne Boulevard, Suite 205 Miami, FL 33161 Instrument Prepared By: CHRISTOPHER P. KELLEY, Esquire 11098 Biscayne Boulevard, Suite 205 Miami, Radda 33151 Folio No. 11-3205-017-0090 WARRANTY DEED CFN: 20140050467 BOOK 28998 PAGE 2327 DATE:01nk014 10.`07:19 AM DEED DOC 3,480.00 HARVEY RUVIN. CLERK OF COURT, MIA-DADE CTY THiS INDENTURE, Made this t'` day of Ja•+��.-�2014, Between WILLIAM MANSO and ELIZABETH MANSO, husband and wife, GRANTORS, and CORNELIU LUCA and LUMINITA LUCA, husband and wife, whose post office address is 1055 NE 97 Street. Miami Shares, FL 33138, GRANTEES, WITNESSETH, That said GRANTORS, for and in consideration of the sum of Ten and No/100 ($10.00) Dollars, and other good and valuable considerations to said GRANTORS in hand paid by said GRANTEES, the receipt whereof is hereby acknowledged, have granted, bargained and sold to the said GRANTEES, and GRANTEES' heirs and assigns forever, the following described land, situate, lying and being in Miami -Dade County, Florida to -wit: Lot 9, Block 180, of revised Plat of MiAMI SHORES SECTION B, according to the Plat thereof, recorded in Plat Back 43, Page 51, of the Public Records of Miami - Dade County, Florida SUBJECT TO: Applicable zoning and/or restrictions and prohibitions imposed by governments[ authority; Conditions, Restrictions limitations, reservations, easements, and other matters appearing on records, if any; Utility easements of record, and taxes for the year 2014 and subsequent years. and said GRANTORS do hereby fully warrant the title to said land, and will defend the same against the lawful claims of all persons whomsoever. IN WITNESS WHEREOF, GRANTORS have hereunto set their hands and seats the day and year first above written. rrm�c mr.+ p l�kgrr- Print Name STATE OF FLORIDA COUNTY OF MiAMI-DADE j WILLIAM MANSO Grantor 8048 South Lake Drive West Palm Beach, FL 33406 EL1ZA - H MANSO Grantor 8048 South Lake Drive West Palm Beach, FL 33406 I HEREBY CE=RTIFY that on this day, before me, an officer duly authorized in the State and County aforesaid to take acknowledgments, personally appeared WILLIAM MANSO and ELIZABETH MANSO, who produced FQ /-_ and t•ne , respectively, as identification, and who executed the foregoing Instrument and acknowledged before me that they executed the same. WITNESS my hand and official seal in the County and,Std last aforesaid this �'`� day of 2014. My commission expires: NOT ELIC, State of FLO Aamarge +,T n(t tlnt�ty'uhOt 5131ao1 FIarM3a �c:� .� 'tq (:tJ,tutin:SlaN E£t$�535 r. n PropartySearch- Report , M IAM I-DADE COUNTYPROPERTY APPRAISER t�AsN . ' 0 } PROPERTY APPRAISER Proper .a- Property Infernmfion: Folio 11-3205-017-0090 Property Address 1065 NE 97 ST Owner Name(s) O1J LICA LUMNTA LIJCA Meiling Address 1065 NE 97 ST MIAMI SHORES FL 33138 PrimaryZone 1400 SGL FAMLY - 3001-3250 SQ Use Code 0101 RESDENTIAL - SWGLE FAMILY :1 UNIT Beds/Baths/Half 2/1/0 Floors 1 Living Units 1 Adj. Sq. Footage 2,409 Lot Size 8,475 SQFT Year Built 1950 Full Legal Description RIS/ PL MIAMI SHORES SEC 8 PB 43-51 LOT 9 BLK 180 LOT SIZE 75.000 X 113 OR 19304-3468 09 2000 4 COC 21656-2092 09 20031 Assessment Information: Year 2013 2012 Land Value $155,012 $146,632 Building Value $163,330 $182,595 Market Value $318,342 $329,227 Assessed Value $302,7681 $297,707 Benefits Information: Benefit Type 2013 2012 Save Our Homes Cap Assessment Reduction $15,574 $31,520 Homestead Exemption $25,000 $25,000 Second Homestead Btemption $25,000 $25,000 Note: not all benefits are applicable to all Taxable Values (ie County, School Hoard, City, Regional). Disclaimer: 1AAMal Photography M2 Taxable Value Information: Year 2013 2012 Btemptionl Taxable Esemption/ Taxable County $50,000!$252,768 $50,000/$247,707 School Board $25,0001$277,788 $25,000/$272,707 City $50,0001$252,768 $50,000/$247,707 Regional $50,0001$252,768 $50,0001$247,707 Sale Information: Date Amount ORBook-Page Qualification Code 01!2112014 $580,000 28998-2327 Corrective, tax or QCD; min consideration 09101 /2003 $392,000 21656-2092 2008 and prior year sales; (lual by exam of demi 09/01/20 $0 19304-3468 Qual by exam of deed The Office of the Property Appraiser and Miami -Dade County are continually editing and updating the tax roll and QS data to reflect the latest property information and GIS positional accuracy. No warranties, expressed or implied, are provided for data and the positional or thematic accuracy of the data herein, its use, or its interpretation. Although this website is periodically updated, this information may not reflect the data currently on file at Miami -Dade County's systems of record The Property Appraiser and Miami -Dade County assumes no liability either for any errors, omissions, or inaccuracies in the information provided regardless of the cause of such or for any decision made, action taken, or action not taken by the user in reliance upon any information provided herein. See Miami -Dade County full disclaimer and User Agreement at http:/Avww.miamida&.gov/info/disrlaimer.asp. Property information inquiries, comments, and stVgcstions email: pawebmail@mkmidade.gov GIS inquiries, comments, and suggestions email: gW@miamidade.gov Generated on: Fri Feb 28 2014 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: COM 4 " lu- 1-"X Property Address: 10 b.5 W15 q r7+h Roofing Permit Number: Dear Building Official: I W 6A- certify that I am not required to retrofit the roof to wall connections of my building because: WThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 editio a South Florida Building Code (1994 SFBC) 7r 1 (0",/-- 41u Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 2 day of Notary Public, Sate of Florida at Large • When the just valuation of the structure for purpose of ad valorem taxation Is equal to or more than $300,000.00, and the bu inRnot SFBC. Then you must provide a building applIc ation from a General Contractor for the Roof to Wall connection Hurricane Mitlgation. Revised on 621@0 judgment and knowledge of local/regional wage scales can provide additional guidance to determine reasonable labor rates for professional trades (i.e. electricians, plumbers, block masons, framing, HVAC). SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE ITEMS TO BE INCLUDED (Please check off each line) ALL STRUCTURAL ELEMENTS INCLUDING: [ ] Spread or continuous foundation footings and pilings [ J Monolithic or other types of concrete slabs [ ] Bearing walls, tie beams and trusses [ ] Wood or reinforced concrete decking or roofing [ ] Floors and ceilings [ ] Attached decks and porches [ ] Interior partition walls [ ] Exterior wall finishes (e.g., brick, stucco or siding) including painting and decorative moldings [ ] Windows and doors ["p -shingling or re -tiling a roof [ ] Hardware ALL INTERIOR FINISH ELEMENTS, INCLUDING: [ ] Tiling, linoleum, stone or carpet over sub -flooring [ ] Bathroom tiling and fixtures [ J Wall finishes (e.g., drywall, painting, stucco, plaster, paneling, marble or other decorative finishes) [ ] Kitchen, utility and bathroom cabinets [ ] Built-in bookcases, cabinets and furniture [ ] Hardware ALL UTILITY AND SERVICE EQUIPMENT, INCLUDING: [ ] HVAC equipment [ ] Repair or reconstruction of plumbing and electrical services [ ] Light fixtures and ceiling fans [ ] Security systems [ ] Built-in kitchen appliances [ J Central vacuum systems [ ] Water filtration, conditioning or recirculation systems ALSO: [ J Labor and other costs associated with demolishing, removing or altering building components [ ] Overhead and profit ITEMS TO BE EXCLUDED Plans and specifications Survey costs Permit fees Debris removal, (e.g., removal of debris from building or lot, dumpster rental, transport fees to landfill and landfill tipping fees), clean-up (e.g., dirt and mud removal, building dry out, etc.) Items not considered real property such as: throw rugs (carpeting over finished floors), furniture, refrigerators, appliances which are not built-in, etc. OUTSIDE IMPROVEMENTS, INCLUDING: Landscaping Sidewalks Fences Yard lights Swimming pools\spa Screened pool enclosures Sheds Gazebos Detached structures (incl. garages) Landscape irrigation systems Docks and Davits Seawalls Driveways Decks ITEMS REQUIRED TO EVALUATE YOUR APPLICATION APPLICANT MUST SUBMIT ALL OF THE FOLLOWING (please check off each item): 1. Completed and signed application for substantial damagermprovement review (included in this package). 2. Elevation certificate if property is located above base flood elevation. 3. Property Owner's Substantial Damage or Substantial Improvement Affidavit signed, notarized and dated (included in package). 4. Contractor's Substantial Damage or Substantial Improvement Affidavit signed, notarized and dated (included in package). 5. Estimated Cost of reconstruction/improvement form (included in package) and all required backup. Include subcontractor's bids and itemized cost lists (see footnote on Cost Estimate Form). 6. This checklist. 7. Copy of construction contract. If the owner is the contractor, submit all subcontractor bids to document the cost estimate. SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE APPLICATION FOR SUBSTANTIAL DAMAGE OR SUBSTANTIAL IMPROVEMENT REVIEW -6n Sr Property L'SWrier'sW �N�am`}e: Lo a Property Owni1.s A red$ Property Owner's Phone Number: .30� _ 3o.1— 3611,19 Contractor's Name:?W [ �n . , A 401 i(k• Contractor's 59 41 sco t oG( ,�� Address: -UY0 ,)-1 i- 9&40 Flood Zone BFE Lowest Floor Elevation (Excluding garage or carport) Check one of the following: [ ] I am attaching a State Certified Appraiser's report, valuing the structure at: Friam not attaching a State Certified Appraiser's report and I accept the use of the valuation of my property that has been rec ed by the County Property Appraiser's Office. SIGNATURES: � Property Owner: Date: Contractor: Date: Property Address: SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE PROPERTY OWNER'S SUBSTANTIAL DAMAGE OR SUBSTANTIAL IMPROVEMENT AFFIDAVIT Contractor's Name: r r Yp , - PO4-� r i,� n_ ` Property Owner's Name: & W U t , CA Property Owner's Address: 1065 k IC 191 119r Property Owner's Phone -3Q5 , 3oq I - 39 In Number. I hereby attest that the list of work and cost estimate submitted with my Substantial Damage or Substantial Improvement Application reflects ALL OF THE WORK TO BE CONDUCTED on the subject structure including all additions, improvements and repairs and, if the work is the result of Substantial Damage, this work will return .the structure at least to the "before damage" condition and bring the structure into compliance with all applicable codes. Neither I nor any subcontractor or agent will make any repairs or perform any work on the subject structure other than what has been included in the attached list. I UNDERSTAND THAT I AM SUBJECT TO ENFORCEMENT ACTION, WHICH MAY INCLUDE FINES, IF ANY INSPECTION OF THE PROPERTY REVEALS THAT 1, OR MY CONTRACTOR, HAVE MADE REPAIRS OR IMPROVEMENTS NOT INCLUDED ON THE ATTACHED LIST OF REPAIRS OR THE APPROVED BUILDING PLANS. See attached itemized list. STATE OF COUNTY OF e1� Before me this day Pers a y appeared Corn 4-1 r 0 @ . /-tte-&.. , who, being duly sworn, depose a ays that he/she has read, understands, and agrees to comply with all the aforementioned i ' n .mil Property Owner's Signature Sworn to and subscribed before me this day of , 20_&. Notary Public State of fl - My commission expires • �A}� 111il01�T Property Address: SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE CONTRACTOR'S SUBSTANTIAL DAMAGE OR SUBSTANTIAL IMPROVEMENT AFFIDAVIT 11D05 a - C;. IST Contractor's Name: �� I K�Lj A- i e r, Contractor's Company Name: ?*0 i �WA I�� h � mc,, ' & -� , Contractor's Address: �g C f �� G Contractor's Phone Number: 945 --)64- Df9 i Contractor's State Registration 7 _Mg �Ne . 3302 Contractor's We Registration Number (if applicable): I hereby attest that I, or a member of my staff, personally inspected the subject property and produced the attached itemized list of repairs, reconstruction and/or remodeling which are hereby submitted for a Substantial Damage or Substantial Improvement Review. The list of work contains ALL OF THE WORK TO BE CONDUCTED on the subject property. If the property sustained Substantial Damage, this list of Work, will return the structure to at least its condition prior to damage and bring the structure into compliance with all applicable codes. I further attest that all additions, improvements or repairs proposed for the subject building are included in this estimate and that neither I nor any subcontractor or agent representing me will make any repairs or perform any work on the subject structure other than what has been included in the attached list. I UNDERSTAND THAT I AM SUBJECT TO ENFORCEMENT ACTION, WHICH MAY INCLUDE FINES, IF ANY INSPECTION OF THE PROPERTY REVEALS THAT I, OR MY CONTRACTOR, HAVE MADE REPAIRS OR IMPROVEMENTS NOT INCLUDED ON THE ATTACHED LIST OF REPAIRS OR THE APPROVED BUILDING PLANS. See attached itemized list. STATE OF 1,!7,r" COUNTY of Before me this day personally appeared e , who, being duly sworn, deposes and says that he/sh6 has read, understands, and agrees to comply with all the afore° Wtion dations: o ` Contractor's Si n g ature Swom to and subscribed before me this &Q Oqy of /-e LjQg2d , 20 / V. My comi�' "n�n eNpohblic s,RW Of S� : Joanna M Felldano My Commission FF 082753 Expires 01/12/2018 Application Cost Estimate of Reconstruction / Improvement Number Date Address —� This cost estimate of reconstructionlimprovement must be prepared by and signed by the contractor or by the owner If the owner acts as the contractor. Owners who act as their own contractors must estimate their labor cost at the current market value for any work they Intend to perform. Sub -Contractor Bids Contractor Pr Owner Estimates 00 Bid Amounts (see note "D") 1. Masonry 2. Carpentry Material (rough) 3. Carpentry Labor (rough) 4. oofi 5. Insulation and Weather-strip 6. Exterior Finish (stucco) 7. Doors, Windows & Shutters 8. Lumber Finish 9. Hardware 10. Drywall 11. Cabinets (Built-in) 12. Floor Covering 13. Plumbing 14. Shower/Tub/Toilet 15. Electrical & Light Fixtures 16. Concrete 17. Built-in Appliances 18. HVAC 19. Paint 20. Demolition & Removal 21. Overhead & Profit Material 6� �� La or Costs Costs_ `t p p w 17L Z 0 La o E: s FEB 2a 2014t; I'Ty 11GOR 1MOCmr NURMCME WW . Z? w 3W Ria m Florida Building ode Edition1�i 0 Section A (General Information) Master Permit No. ,Process No. Contractor's Name � �.t V "* R00 i m Job Address IV 5 ,5 q r7+)N .S+ • ROOF CATEGORY 4 Low Slops ❑ Mechanically Fastened isle WMortadAdhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles ❑ Prescriptive BUR -RAS 95o ROOF TYPE Q New Roof 1� Reroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 9!50 Section B (Roof Plan Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. �fy Ib`' �.. _ }. ,�. IPJ :.. •• �-i .�• �. . �. _: ..� .i•i ._ HIGH VELOCITY HURRICANE ZONES Florida Building Code Edition 2010 H911 Yelack Y Hurricane Zone tfNforrn Permit AWICdM Fonn. SeCtinl1 G (Low Slope Ayoliw1lon) Fill in Specific Roof Assembly Components Fastener Spacing for Anchodease Sheet and identify AAanufacturer Attachment Of a component Is not used, Me" as -NA-) System Manufacturer. AF 1 NOA No.: 3 —Oq aq t N Design Wind Pressures, From RAS 128 or Calcuations: Max. Design Pressure, From the Specific NOA System:`��,s Deck Type:-- 14ii i i` �` ir> G' Gaugetrhickness: Slope: AndwrBase Sheet & No. of Ply(s): j SC' A orr' L� d i iVt�t i 13ad ng a TIn � Insulation Base Layer. .J. Base Insulation Size and Thiduvw:� Base Insulall n F�as er g Material: •t- ill i�' Top insulation Layer Top Insulation Size and Thidmess: Top Insulation FastenerBonding Material: Base Shee(s) & No. of Ply(s): P Base Sheet FastenerBonding Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet FastenerBonding Material: Top Top Ply iA.O �iY'�GiT t I: Surfacing: Fiekk� foc @ Lap, E Rows L q "cc Perimeter. V° " oc @ Lap. # RMS @ ° oc Comer. k! ° oc @ Lap, # Rears 41—@..L -OC Number of Fasteners Per Insulation Board Field Perimeter Comer Illustrate Components Noted and Details as Applicable: Woodbtoddng, Gutter, Edge Termination, Shipping, Fleshing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. In f : Mean -Roof Height; Parapet Height, Height of Base Flashing, Component Material, Material Thiclmess, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 911 and Chapter 16. WlV\e4-VLA CAP FT. �M' v &ip Heia e t �hc 510. " ID W Woo CL Mean j ' Roof a t l6+r� P Height ROOF ASSEMBLES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High -Velocity Hurricane Zane Uniform Penna Application Foran. Roof System Manufacturer: v ore1 Notice of Acceptance Number: � L __ OAaQAN► 03 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations 121: P2• bq a 133: j 00i r Maximum Design Pressure (From th=ct Approval Specific System): Deck type: 1 X �"' - t1 t l'1"� VA/Vv Type Underlayment: Roo Slope: ' 121 Insulation: N Ilk Fire Barrier: Ridge Vett n? Fastener Type & Spacing: 11/41 e� Adhesive Type: Ui Li'l cg Type Cap Sheet:�- �A Mean Roof Height: 1 �-i Roof Covering: Type & Size Drip ��( ��li/ Edge: ���i�{'•}i�L?.1S FLORIDA BUILDING CODE —BUILDING INE Section E ,Mis Calculations) For Mommt band the sY choose either Modwd 1 or L Compare the vskm for ill,wM #m vidues from W if as akvmuw are giemm Om or equal to'ihe values, for each area of the roof, thM tfte the attachment medwd is acceptable. - mor Bawl Tft Cafeuk g� Per RAS IZr � (Pt: a x�� __�: =fides �w /1� Rte,. (PS: IMA f I x h a 313 =-91 0 =mi . = UrA Rt'.dii hoof "aiam -41- f t►t 5' 2W 25' 3W 4W 212 34.4 36.5 38.2 39.7 42.2 3:12 2" 24A Me 27.4 39.6 4.92 30.4 32-2 33.3 35.9 37.3 5:12 28A 30.1 9 31.6 } 34,9 j 512 26A 2-0,0 29e® 39;5 n 8 7:12 24A 25.9-07.1 2" 30.0 a. '.1. ._ 1 .f' -".-. : f :�' -. ._ "1.(.+ ..i1 .:1 a ff-:�..ci f- -•. � .r. McMad 3 fit Ekwed Tfie Cakmdadom Per RAS 12e7" (P,:—xl: = x _ )-W: xcwfk - =F,, PmductftpravalP (P7 x 1: a It 1- W: x Ctrs M - = Fr, F -- . Wetere � Cir$ cri oaa to Owd tfi i ort' or ia3 l t15 itr i orgy an grebe isg r c b aci mn ria : �. • t�Ya83 R'$SSf� :1�R,gf� � A L � -zc 4. £ir°gyn-gS?k LenSwT 4F0 M*m&9dUO to QrwAy & f p���� p*,� �� Ram*ed !RL ent WOmm pp� f•�tFMdM �n� r ba •�� F. Cab Aer ap 100 •f *d w aa. A m st be mOnMed to &t6 &Gft tom' at Me f rw of M40mam , SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permti, and to explain to the owner the content of the motion. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as coloror architectural appearance, that are not part of a zoning code, should be address as part of the agreement between the owner and the contractor. 2. k1-- Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailai In accordance with the current provisions of Section R4403. (The roof deck Is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. 'Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. SPonding water. The current roof system and/or desk of the building may not drain well and may cause water to pond (accumulate) In low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. !2 Overflow scuppers (wall outlets): it is required that rainwater flows off se that the roof Is not overloaded from a buildup of water. Perimetededge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. cy, '" Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shag not be reduced. may be beneficial to consider additional venting which can result In extending the service iife of the roof. OwnedAgents Signature Date Contractor Signature Date Revised on 719/2009 LD SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construe materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be, used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHI). This NOA shall not be valid after the expiration date stated blow. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AEU (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by MminDade County Product Control Section that this product or material &Us to meet the regwrements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Badding Code including the High Velocity Hurricane Zone of the Florida Building Cale. DESCRIPTION: Saxony 900 Concrete Roof Tile LA=uNG: Each unit shall bear a pmmanent label with the maaufac urces name or logo, city, state and following statement: "Miami Dade County Product Cartrol Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMIr1ATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically ate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its dislributois and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#07-0711.03 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigers. NOA N6.:12 0222.03 t ` : Esphmdon Date: 64fM7 Approval Date: 04119/12 Pavl of t3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Test Identifier Test Product Apiplicant Dimensions specifications Description Saxony 900 1=17" TAS 112 Flat profile, interlocking, high - The Center for Applied w =13" Static Uplift Testing pressure extruded concrete roof tile Engineering, Inc. 1-5/32" thick Slate TAS 101 (Mortar Set) equipped with two nail holes. For The Center for Applied 1-9/32" thick Shake & Static Uplift Testing direct deck or battened nail -on, mortar Engineering, Inc. Split Shake TAS 101 (Adhesive Set) set or adhesive set applications. Trim Pieces Length: varies TAS -112 Accessory trim, boosted Barcelona, Width: varies concrete roof pieces for use at hips, varying thickness rakes, ridges and valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL. 2.2 SUBmTrTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94-060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) i. 51 *K01 JAPPROVEDI NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 2 of 8 The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 25-7183-6 Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Direct Deck) 25-7183-5 Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Battens) 25-7214-1 Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Direct Deck) 25-7214-5 Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Battens) 7161-03 Wind Tunnel Testing Appendix H TAS 108 (Nail -On) Letter Dated Aug. 1, Wind Tunnel Testing 1994 TAS 108 (Nail -On) P0631-01 Wind Tunnel Testing TAS 108 (Mortar Set) P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails Project No. 307025 Wind Driven Rain Test #MDC -77 TAS 100 R1.894 Physical Properties R2.894 TAS 112 R3.894 520109-1 Static Uplift Testing 520111-4 TAS 101 520191-1 Static Uplift Testing TAS 101 Evaluation 25-7094 Calculations Evaluation 25-7496 Calculations Evaluation 25-7584 Calculations 25-7804b-8 25-7804-4 & 5 25-7848-6 Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 3 of 8 v Walker Engineering, Inc. Evaluation 25-7183 March 1995 Wldth-w (ft) Calculations 11.5 1.417 Walker Engineering, Inc. Evaluation Aerodynamic Multipliers January 2007 Calculations Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 130 TAS 112 January 2007 3. LnwAnon 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w) Tile Profile Welght-W (Ibf) Length -I (ft) Wldth-w (ft) Saxony 900 Slate, Shake $ Split Shake 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -;L (ft) Tile X (ft) X (ft Profile Batten Application Direct Deck Application MonierLif@tile Saxony 900 0.289 0.313 Slate, Shake & Split Shake NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approvals Date: 04/19/12 Page 4 of 8 Table 3: Restoring Moments due to Gravity - M9 (ft4bf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile 38.1 17.2 Slate, Shake 8 Split Shake 1-10d Smooth or Screw Shank Nail 7.3 greater Saxony Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 900 1-10d Smooth or Screw Shank Nail Field Clip) Deck 24.3 Deck 1-10d Smooth or Screw Shank Nail Eave Clip) Deck 19.0 Deck Deck 35.5 Deck Slate, 7.16 8.12 7.08 8.03 6.97 7.91 6.82 7.74 6.65 7.55 6.46 7.34 Shake & Split Shake Table 4: Attachment Resistance Expressed as a Moment - Mf (ftdbf) for Phil -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Saxony 900 2-10d Fting Shank Nails 30.9 38.1 17.2 Slate, Shake 8 Split Shake 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance MonierLifetile Saxony 900 Adhesive 31. Slate, Shake & Split Shake 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 13.9 grams. PoWdam Product, Inc. Average weight per patty 8 grams. NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 5 of 8 r 4 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft4bf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Polylbarn PolyProTm 118.9 Pol oam PolyProTm 40.4 3 Large paddy placement of 45 rams of PolyProTm. Mortar Set 4 Medium paddy placement of 24 grams of Pol ProTm. Slate, Shake & Split Shake Table 7: Attachment Resistance Expressed as a Moment - Mf(ft4bf) for Mortar Set Systems Tile Tile Attachment Profile Application Reslstan MonierLifetile Saxony 900 Mortar Set 43.8 Slate, Shake & Split Shake 5. Tile-Tite Roof Tile Mortar J 5. LABELING MAY 7 4 )013 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name pr'logo as detailed below, or following statement: "Miami -Dade County Product Control_Approved": , LABEL FOR SAXONY 900 TILE (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0222-03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 6 of 8 4 NAIL F W PROFILE DRAWING WATERLOCK SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL) 6132 " (slate) 9/32 " (shake) fERLAY MONIERLImim SAXONY 900 CONCRETE ROOF TELE (SPLIT SHAKE MODEL) NOA No.:12-0222A3 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 7 of 8 4. MoNiERIAFFTn.E SAxoNY 900 CONCRETE ROOF TmE (SHAKE MODEL) END OF THIS ACCEPTANCE NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 8 of 8 • T • MIAMUADE ® MIAAO-D�tHL� QOIDV'!°Y� • • • • PRODUCT CONTROL SECTION • DEPARTNMNT OF PER11II'1T RG, ENVMON11IENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 S0A Sob 208 • • • • i • BOARD AND CODE ADMaVISTRATION DIVISION Miami, FWddP33119-2474 T (786) 31S-2590 F (786)SIS-2599 • s •' •' NOTICE OF ACCEPTANCE (NOA) WWW-ndandeg"Kamn 3M Company 3M Center Building 022"54416 . ••: St. Paul, MN. 55144-100 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of duction materials. The documentation submitted has been reviewed and accepted by Miami Dade County PERA - Product Control Section to be used in Miami Dade County and other areas when allowed by the Authority Having Jurisdiction (AEU). This NOA shall not be valid atter the expiration date stated below. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance nce purposes. N this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if A is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building cock. This product is approved as descn1W herein, and has been designed to comply with the Florida' Building Code including the High Velocity Hurricane Zone of the Florida Budding Code. IiESCRIPTION: 3MTM 2 -Component Foam Roof Tile Adhesive AR -160 LABELING: Each unit shall bear a went label with the manufactxuel" s name or logo, city, state and following statement 'Miami Dade County Product Control Approves", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this pry ict. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTMEAH NT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. N any portion of the NOA is displayed, Bien it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manuf iaturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigers. NOA No. -1248228.18 Eamon Data.. WNW,"' Approval Dada» 000/12 Page i of 7 A , , ROOFING COMPONENT APPROVAL: • • • • • • • • • Category: Roofing •' Sub Category: Roof file adhesive Materials: Polyurethane • • . • . • SCOPE: • . This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Companf'ds " described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Pro Dimensions ® Test Product Description Specifications 3MTM 2 -Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH - 160 Foam Dispenser RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.61bs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./FV Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F.,100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 Note: The physical properties listed above are presented as typical average values as deterrow� • by accepted ASTM test methods and are subject to normal manufacturing variation.• 01/16/95 Trinity Engineering 7050.02.96-1 EvIDENcE SUBNTrTED: 03/14/96 • • • • Test Agency Test Identifier Test NamefflRoort • Center for Applied Engineering #94-060 TAS 101 04108/98 257818-1PA TAS 101 12ild/90 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services 5284542-1 TAS 101 10/23/98 5284549-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 WnTATIoNs: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high file profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 roof tile adhesive with their file assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. rF _W 2 MS APPROVED! NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 3 of 7 U� ...... ...... INSTALLATION: • • 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 maybe used with any roof file assembly having a current . , NOA that lists uplift resistance values with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AN -160. • • • • • • 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide suffid8a£ attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MI 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per file as determined at calibration. No other settings shall be approved. 6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF 1000 or ProPack0 30 & 100 dispensing equipment only. 7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTm 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic file profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile 2 Piece Barrel #1 17/side on cap and 34/ N/A Flat, Low High Profiles 1 #2 24 N/A Flat, Low, Iligh Profiles 1 #3 1 1 8 NOA No.: 12-0228.18 Expiration Date. 05/10/17 Approval Date: 05/10/12 Page 4 of 7 0 0 0 0 0000 LABELING: • All 3M7m 2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the StandardC-@;Ations:::::: listed herein. *0 0 WELDING PERMIT REQUIREMENTS: :00000 00 . : As required by the Building Official or applicable building code in order to properly evaluate the installation tfibis system ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Mftm*pwftcwmd 1 10 FSS* EM =M 0* EmCbm Vj"8ft"R*M 41LupfkmweW%ft Emdom FIRMISMS! CPO" pow"Moft pdtb" NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 PIANO Emdom FIRMISMS! CPO" pow"Moft pdtb" NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY 711 1 .77;� V'09080 NOA No.: 12-022&18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 0000 0 0 ADHESIVE PLACEMENT DETAEL 3 :Goo*@ 0:00:. 0 DOUBLE PATTY 00 0 •0000• 00 00 a :00:0: 0 Nall dwough pMft cment singlepadOt"Werre"a wwantfle) Undwhyment wn&wq"6 Pb* ape x 7 In. modpeftem km (undertne) sim • mmordy 40" Sinop* 0,1131-IrLx 3 hL M underdle x3k I 41L 2hL NSb* My on z M. 41n. paddyon unUwdfw**6 under - 0 Isyrnent Single Fescie Eave counle atop of too weelfich Eme 81"Ibe p P* In. X7 In. memo com Em donne an toof tHe Fdmpaddyem % D*edp ee* course . . . . . . . . . . . . ...�� rte/ END OF THIS ACCEPTANCE NOA No.: 12-0228.18 Expiration Date-- 05/10/17 Approval Date: 05/10/12 Page 7 of 7 MIAMl�ADE •' • • MIAMI-DAISE COUNIIf •' PRODUCT COAFAI:SECTIOAI• • • • DEPARTMENT' OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 Sw 26'Shvd Room 208 . • BOARD AND CODE ADMINISTRATION DIVISION Miami, Flod%33:75-2474 • T(786)315-2590 F'(78@� S 15 259y� NOTICE OF ACCEPTANCE (NOA) vmw.m1an &de. %°n°°�• 0600 Polygiess USA Inc. 150 Lyon Drive • 0 Fernley, NV 89408 • • • • SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance proposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AM may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. JAPPROVED NOA No.: 12-0713.02 '! Expiration Date: 09/13/16 Approval Date: 02/14/13 Pane 1 of 8 1 I ROOFING COMPONENT APPROVAL ' •' Catefforn Roofing • Sgt-Cateeory Underlayment • Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: • Test Product ;""' o u Dimensions Spg� on Descrigdou Polystick MTS Roll: TAS 103 . . A homogeneous, rubberized asphalt " underlayment 65'8" x 3'V/8" waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick IR -Xe Roll: TAS 103 and A fine granular/sand top surface self -adhering, underlayment 65' x 3'3 3/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32'10" x 3'3 3/e" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1&#2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self -adhering, glass- underlayment 65' x 3'3-3/8" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof Manufacturing Location tile underlayment. #1 & #2 Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10" x 3'3 3/s" ASTM D 1970 glass-fiber/polyester reinforced, with a granular Mam facturing Location 130 mils thick surface designed for use as a file roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass- Manufachaing Location 61' x 3'3-3/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof file underlayment. Polystck Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass- ManufacturingLocation 161'x 33-'/B" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: .. Test Product'00 0000 Product Dimensions Specification description 0" 0. . Polystick TU Max Roll: TAS 103 and A rubberized asphalt self -adhering, ;ofyesfer ... :' MwmfacturingLocation 65'8" x 31-3/8" ASTM D 1970 reinforced waterproofing membrangr D.esoed ...... 60 mils thick as a a roof tile underlayment. • • • • ...... .. . MANUFACTURING PLANTS: •. • • 0*: • • • . 1.Hazelton, PA ' 2.Winter Haven, FL EVIDENCE SUBMrt TED: Test Amem ,Test Test Name JReport Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity SRU P5110.08.07 TAS 103 08/29/07 P10870.09.08 -R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-1 TAS 103 & TAS 110 08/06/12 P40390.08.12-2 ASTM D 1623 08/07/12 P40390.10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PRIM I I I ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. 7X20H7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23D8A TAS 103/ASTM D4798 & G155 02/18/10 Mtaau�aoe cISDO NOA No.: 124713.02 ... , Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 9 2 ` .000.0 INSTALLATION PROCEDURES: • • 0 • Deck Type 1: Wood, non -insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. • • • • 6009:9 Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" hVed jag (for , ; base sheet only) •' 00 0000.. 00 Membrane: Polystick membranes self -adhered. ' • • 0000.. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decki$g phils, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3-1/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 4 of 8 GENERAL UwTATIONS: .. 1. Fire classification is not part of this acceptance. .... 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and skingles, ' non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR Xe;' , and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max maybe pd in , roof tile systems only. 0000* 3. Deck requirements shall be in compliance with applicable building code. • • • 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck sh911 be free of irregularities. . •• •. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a mover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. e Limitations da MTS M -Xe TU TU Plan TU P Tile Pro Dual Pro TU Max Winter Haven, FL. 180 180 180 180 180 180 180 90 Hazelton, PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Cade and Rule 9N-3 of the Florida Administrative Code. & In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof file applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) file assemblies shall be as follows: (See Table Below) Tile Proftle Polystick MTS Polystick IR -Xe Polystick TU, TU Polystick TU Plus, TU P, Tile Max Pro Flat Tile Prohibited without 5:12 No limitation No limitation battens Profiled Tile Prohibited without Tbattens Prohibited No limitation No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of dies at all times. APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Paee 5 of 0000.. GENERAL LIMITATIONS: (CONTINUED) 0600 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping oP . tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading proce$ure►&r all ...... underlayments except Polystick MTS which shall be loaded onto battens. 0 . . . .....6 0. .. ...... .0 . .0.900 . 0. . 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, JR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AIS or the Miami Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. 1�'BAMI�ADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 6 of 8 POLYGLA5S GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANE4: '.. • 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood deck. hhtallers • are cautioned to refer to applicable local building codes prior to direct deck installation to ensure:'tht.4 fs" • • • • • • acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. • . ` • `. • 2. All rolls, with the exception of Polystick TU Plus should be back -naffed in selvage edge seam as pei Volyglass .. �. Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metaldisk gs • • • required in Dade County or simplex type nail as otherwise allowable in other regions, at a mining tft of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para rdavai' on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to coves th'eparea being back -nailed. (Please refer to applicable local building codes prior to installation.) I All seal lap seams (selvage laps) must be rolled with a hand roller to ensure finll contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of T'/12" or greater. It is suggested that on pitch/slopes in excess of 6'/a"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. & Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should he installed in such a way so that water will nun parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 1VOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 • 13. Questions in regards to the application of Polyglass products should be directed to our TechnicalSe3ryu*es Department at 1(800) 894-4563. *0 *060 . 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures -& *xAmed • • • • � • by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC • APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS ANV.• RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 12-0713.02 LAPPRe Er, F.Bpiratlon Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 9 rm MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GAF Ruberoid® Modified Bitumen Roof System for Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09-0224.01 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. APPROVED NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 1 of 29 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Matrix'M 102 SBS 5 gallons ASTM D3019 Fiber reinforced rubberized cold -applied Membrane Adhesive adhesive for modified bitumen roof systems. GAFGLAS® #75 39.37" ASTM D4601 Type H asphalt impregnated and coated Base Sheet (1 meter) Wide glass mat base sheet. GAFGLAS® #80 Ultima 39.37" ASTM D4601 Type H asphalt impregnated and coated, Base Sheet (1 meter) Wide fiberglass base sheet. GAFGLAS® F1exPlim 6 39.37" ASTM D2178 Type VI asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS® Ply 4 39.37" ASTM D2178 Type IV asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS®Mineral 39.37" ASTM D3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet (1 meter) Wide surfaced with mineral granules. GAFGLAS® EnergyCap"' 39.37' ASTM D3909 Asphalt coated, glass fiber mat cap sheet BUR Mineral Surface Cap (1 meter) Wide surfaced with mineral granules with Sheet factory applied EnergyCote"' GAFGLAS® Stratavene 39.37" ASTM D4897 Fiberglass base sheet coated on both sides Eliminator Perforated (1 meter) Wide with asphalt. Surfaced on the bottom side Venting Base Sheet with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS® Stratavene 39.37" ASTM D4897 A nailable, fiberglass base sheet coated on Eliminator Perforated (1 meter) Wide both sides with asphalt. Surfaced on the Nailable Venting Base bottom side with mineral granules Sheet embedded in asphaltic coating. Ruberoid® SBS 39.37" ASTM D6164 Non -woven polyester mat coated with Heat -Weld's Smooth (1 meter) Wide polymer -modified asphalt and smooth surfaced. Ruberoid® SBS 39.37" ASTM D6164 Non -woven polyester mat coated with Heat -Weld'' Granule (1 meter) Wide polymer -modified asphalt and surfaced with mineral granules. RoofMatch'm 107 sq. ft. ASTM D6164 Non -woven polyester mat coated with SBS Modified Granular (9.9 m2) SBS polymer -modified asphalt and surfaced with colored mineral granules. Ruberoid® SBS 39.37" ASTM D6164 Non -woven polyester mat coated with fire Heat -Weld's 170 FR (1 meter) Wide retardant polymer -modified asphalt and surfaced with mineral granules. NOA No.: 13-0424.14 MIAMMMDECOUNTY Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 2 of 29 Test Product Product Dimensions Specification Descri0on Ruberoid® SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld's Plus (1 meter) Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid® SBS 39.37" ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld' Plus FR (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoie EnergyCap' 39.37" ASTM D6164 Non-woven polyester mat coated with fire SBS Heat-Weld's Plus FR (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid® SBS 39.37" ASTM D6163 Non-woven polyester mat coated with Heat-Weld's 25 (1 meter) Wide polymer-modified asphalt and smooth surfaced. Ruberoid® Mop Granule 39.37" ASTM D6164 Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid® Mop Smooth 39.37" ASTM D6164 Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and smooth surfaced. Ruberoid® Mop Plus 39.37" ASTM D6164 Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid® Mop 170FR 39.37" ASTM D6164 Non-woven polyester mat coated with fire (1 meter) Wide retardant polymer modified asphalt and surfaced with mineral granules. Ruberoid® Mop FR 39.37" ASTM D6164 Non-woven polyester mat coated with fire (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoid® Torch Smooth 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter) Wide APP modified asphalt and smooth surfaced. Ruberoid® Torch Granule 39.37" ASTM D6222 Non-woven polyester mat coated with (1 meter) Wide APP modified asphalt and surfaced with mineral granules Ruberoie EnergyCap' 39.37" ASTM D6222 APP modified cap membrane with a torch Torch Granule FR (1 meter) Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote'm. Ruberoie EnergyCap- 39.37" ASTM D6222 APP modified cap membrane with a torch Torch Granule Plus FR (1 meter) Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote'm. RoofMatch'' 107 sq. ft. ASTM D6222 Non-woven polyester mat coated with APP Modified Granular (9.9 m2) APP polymer-modified asphalt and surfaced with colored mineral granules. Ruberoid® Torch FR 1 meter ASTM D6222 Non-woven polyester mat, coated with fire (39.37") Wide retardant asphalt modified bitumen membrane with granule surface. NOA No.: 13-0424.14 MIAMMMDECOUNTY Expiration Date: 11/06/14 �VMJRIMI Approval Date: 10/31/13 Page 3 of 29 Protection NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 4 of 29 Test Product Product Dimensions Specification Description Ruberoid® 20 1 meter ASTM D6163 SBS modified asphalt base sheet reinforce (39.37") Wide with a glass fiber mat. Ruberoid® 30 1 meter ASTM D6163 Non -woven fiberglass mat coated with (39.37") Wide polymer modified asphalt and surfaced with mineral granules. Ruberoid® 30 FR 1 meter ASTM D6163 Non -woven fiberglass mat coated with fire (39.37") Wide retardant, polymer -modified asphalt and surfaced with mineral granules. Ruberoid® EnergyCap- 30 1 meter ASTM D6163 Non -woven fiberglass mat coated with fire FR SBS Membrane (39.37") Wide retardant, polymer -modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid® Dual FR 39.37" (1 meter) ASTM D6162 Non -woven polyester and fiberglass mat Wide coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. Topcoat® Elastomeric 1, 5 or 55 gallons ASTM D6083 An acrylic, water based elastomeric Roofing Membrane membrane system designed to protect various types of roofing surfaces. Topcoat® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to block asphalt bleed -through. Topcoat® 5 gallons ASTM D6083 Solvent based sprayable thermoplastic Surface Seal SB rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. FireOut7 Fire Barrier 5, 55 gallons Proprietary Low VOC, water-based fire barrier Coating coating. VersaShiele 42" x 100' rolls ASTM D226 Non -Asphaltic, fire resistant fiberglass - Fire -Resistant Roof Deck based underlayment. Protection NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 4 of 29 c APPROVED INSULATIONS: Product Name EnergyGuard7 Polyiso Insulation EnergyGuard7 RA Polyiso Insulation EnergyGuarC RN Polyiso Insulation EnergyGuarC Perlite Recover Board EnergyGuarC Perlite Roof Insulation EnergyGuarC RA Composite Polyiso Insulation Various Structodeke High Density Fiber Board SecurocV Gypsum -Fiber Roof Board APPROVED FASTENERS: Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite roof board Polyisocyanurate/wood fiberboard or perlite composite High density wood fiber Gypsum board TABLE 3 Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF Blue Ridge FiberBoard, Inc. United States Gypsum Corp. Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill -Tec'' #12 Fastener Carbon steel fastener used Various GAF in steel or wood decks. 2. Drill-TecTm 414 Fastener Carbon steel fastener used Various GAF in steel, wood or concrete decks. 3. Drill -Teem XHD Fastener Carbon steel extra heavy Various GAF duty fastener used in steel decks. 4. Drill-Tec"m AccuTrac®Flat AZ -SS aluminized steel 3" x 3" GAF Plate plate for use with Drill- Tec7m#12 Fastener, Drill - Tec TM#14 Fastener and Drill -Tec' #15 Fastener. 5. Drill -Tec"' ASAP 3S Drill-Tec"m #12 fastener Various GAF with Drill -Tec' -m 3" Standard Steel Plate. 6. Drill -Tec'-- AccuTrac® Galvalume Steel plate for 3" x 3" GAF Recessed Plate use with Drill -Teem fasteners. 7. Drill -Tec'' 3" Steel Plate Round galvalume steel 3" GAF stress plate for use with Drill -Teem fasteners. 8. Drill -Teem 3" Standard Round galvalume plated 3" GAF Steel Plate steel stress plate with reinforced ribs for use with Drill -Teem fasteners. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 5 of 29 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. 3029832 FMRC 4470 05/11/07 3010215 FMRC 4470 03/01/01 3001276 FMRC 4470 01/28/99 1B9A8.AM FMRC 4470 09/04/97 3D4Q2.AM FMRC 4470 04/30/97 ODIA8.AM FMRC 4470 04/01/98 Underwriters Laboratories R1306 UL 790 07/22/13 Trinity Engineering 4483.04 97-1 TAS 114 06/06/97 PRI Asphalt Technologies, Inc. GAF -020-02-01 ASTM D249 02/01/02 ASTM D4977 GAF 306-02-01 ASTM E96 07/07/11 GAF 315-02-01 ASTM D2178 8/23/11 GAF 314-02-01 ASTM D2178 8/23/11 IRT-ARCON Inc. 02-005 TAS 114 03/01/02 02-014 TAS 114 04/08/02 01-039 TAS 114 03/01/02 Trinity ERD G6850.08.08 ASTM D6164 08/29/08 G6850.08.08 ASTM D6163 08/01/08 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 11/05/08 G40620.07.12-2 ASTM D6222 07/17/12 G34140.04.11-2 ASTM D6163 04/25/11 G31360.03.10 ASTM D6164 03/31/10 G34140.04.11-4 ASTM D4601 04/25/11 G34140.04.11-5 ASTM D4897 04/25/11 G33470.01.11 ASTM D6164 01/13/11 G6850.08.07-1 ASTM D3909 08/13/07 G30250.02.10 -3-R1 ASTM D3909 11/26/12 PRI Construction Technologies LLC. ASTM D2178 GAF -314-02-01 08/23/11 ASTM D2178 GAF -315-02-01 08/23/11 ASTM D6083 GAF -245-02-01 06/10/10 ASTM D6083 GAF -084-02-01 07/08/05 ASTM D6083 GAF -245-02-01 06/10/10 ASTM D6083 GAF -084-02-01 07/08/05 Momentum Technologies, Inc. ASTM D6162 AX04C9A 06/05/09 APPROVED NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 6 of 29 APPROVED ASSEMBLIES Membrane Type: SBS Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A(1): Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. Fire Barrier: FireOut"' Fire Barrier Coating, VersaShield o Fire -Resistant Roof Deck Protection (optional) or SecurocV Gypsum -Fiber Roof Board. Anchor sheet: GAFGLAS® #80 Ultima"' Base Sheet, GAFGLAS® Stratavent® Eliminator"' Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat -Weld"' Smooth or Ruberoid® SBS Heat -Weld"' 25 base sheet mechanically fastened to deck as described below. Fastening GAFGLAS® Ply 4, GAFGLAS' F1exPly"' 6, GAFGLAS® #75 Base Sheet or any Options: of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® FlexPly"' 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill -Tec"' #12 Fastener, Drill -Tec"' #14 Fastener or Drill -Tec"' XHD Fastener and Drill -Tec"' 3" Steel Plate, Drill- Tec"'AccuTrac® Flat Plate or Drill -Tec"' AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of t. (Maximum Design Pressure psf, e neral Limitation #7) GAFGLAS® FlexPly"' 6 AF�LAS`� #7 a Sheet or any of above anchor sheets attached to deck roved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80 Ultima Base Sheet, Ruberoid® 20, Ruberoid® Mop Smooth base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill -Tec"' #12 Fastener, Drill-Tec'?A #14 Fastener or Drill -Tec' XHD Fastener and Drill -Tec"' 3" Steel Plate, Drill -Tec"' AccuTrace Flat Plate or Drill -Tec"' AccuTrace Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 7 of 29 Any of above anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec"" insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLASO #75 Base Sheet or any of above anchor sheets attached to deck with Drill -Tec'.' #12 Fastener, Drill -Tec" #14 Fastener or Drill-TecTm XHD Fastener and Drill -Tec" 3" Steel Plate, Drill -Tec"' AccuTrace Flat Plate or Drill -Tec"' AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener 1 "Q C11C .7� EnergyGuardTm Polyiso Insulation, EnergyGuard" Polyiso RA Insulation, EnergyGuardm Polyiso RN Insulation, EnergyGuarC RA Composite Polyiso Insulatio7NI Minimum 1" thick N/A S crut todeV High Density Fiber Board, EnergyGuarC Perlite Recover Board Minimum %11 thick N/A N/A EnergyGuard7 Perlite Roof Insulation Minimum %11 thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene Eliminator'm Perforated Venting Base Sheet laid dry or a layer of EnergyGuarC Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima Base Sheet, GAFGLAS® Ply 4, GAFGLAS F1exPly'*m 6, GAFGLAS® Stratavene Eliminator° Perforated Venting Base Sheet (laid dry), Ru eroi op moo u eros uberoido SBS Heat-WeIC Smooth or Ruberoid® SBS Heat -Weld's 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 1 e General Limitation #4). ;Pl>yet: �tionne or more plies GAFGLAS® Ply 4, GAFGLAS® FlexPly'*m 6, #80 Ultima Base Sheet, Ruberoid® Mop Smooth, Ruberoid® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid® 20, Ruberoid® 30, Ruberoid® EnergyCap- 30 FR SBS Membrane, Ruberoid® 30 FR, Ruberoid® Mop Smooth, Ruberoid® Mop 170 FR, Ruberoid®Mop Granule, RoofMatch"" SBS Modified Granular, u eros 717%p Plus, Ruberoid® Mop FR or Ruberoid® Dual FR fully adhered in an approved asphalt at an application rate of 25 lb./sq. f 15%. NOA No.: 13-0424.14 M IAMW=E SUN7Y Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 8 of 29 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCap." BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat® Elastomeric Roofing Membrane, Topcoat® MB Plus (to be used as a primer with Topcoat® Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. Maximum Design Pressure: APPROVED See Fastening Above NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 9 of 29 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® FlexPly TM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum '/a" DensDecke Roof Board or '/z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LINIITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE APPR4YtiD NOA No.: 13-6424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 29 of 29 TGFU.R1306 - Roofmg Systems Class A - Fully Adhered 1. Deck: NC Incline: 1/2 Pagel of 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perllte/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet (Optional • — or more plies Type G1 or Type G2 or Type G3. Membrane: — or more plies Torch@" (Smooth or Granule) or "Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop" (Smo or Granule) or "Ruberoid@ Mop Granule" (granule). Surf} — Gravel, 400-lbs/100-ft2, loose laid or a�q(ied in a flood coat of hot roofing asphalt. 2. Deck: NC Incline: Base Sheet (Optional): — One or more plies TypeGi or Ty G2 or Type G3. Membrane: — One or more plies "Ruberoid@ Torch" (Smoot or Granule) or "Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop" (Smooth or Granule) or "Ruberoid@ Mop Plus Granule". Coating: — "Karnak No. 97" applied at 11h to 3-gal./100-ft2. 3. Deck: NC Inclin 1/4 Insulation (Optional): — One or more layers perlite, od fiber, glass fiber, any thickness. Base Sheet (Optional): — One or more plies Type GI r Type G2 or Type G3. Membrane: — One or more plies "Ruberoid@ Torch" mooth or Granule) or "Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop Granule" or "Ruberoid@ Mop Plus Granule". Coating: — "Karnak No. 97" applied at 11h to 3 -gal/ 00-ft2. 4. Deck: C-15/32 1/2 Insulation: — One or more layers perlite, glassber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane composite, phenolic, 11/2-1n. minimum thickness (butt joints staggered a minimum of 6 -in. form plywood deck butt joints). Base Sheet: — One or more plies Type G2 or pe G3. Ply Sheet (Optional): — One or more plies T pe G1. Membrane: —One or more plies "Ruberoid@ orch" (Smooth or Granule) or "Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop" (Smooth or Granule) or "Ruberoid@ Mo Plus Granule." Surfacing: — "Karnak No. 97" applied at 11/4to 3-gal/100-ft2 S. Deck: NC Incline: 1/2 Base Sheet (Optional): — One or more pips Type GI or Type G2 or Type G3. Membrane: — One or more plies "Ruberold Torch" (Smooth or Granule) or "Ruberoid@ Torch Granule Plus." Surfacing (Optional): — Karnak "No. 97" k "169" applied at 1 to 3 gal/100-ft2 or Grundy Ind. "20 F Emulsion" applied at 3-gal/100-ft2. 6. Deck: C-15/32 Incline: 1/2 Insulation: — One or more layers perlite, glass fiber, minh perlite/urethane composite, 11h -in. minimum. Base Sheet (Optional): — One or more plies Type G1 or Type C Membrane: — One or more plies "Ruberold@ Torch" (Smooth or Mop" (Smooth or Granule) or "Ruberold@ Mop Plus Granule." Surfacing: — Gravel. 7. Deck. C-15/32 Incline: 1/2 polyisocyanurate, urethane, perlite/polylsocyanurate composite, G3. it "Ruberoid@ Torch Granule Plus" or "Ruberoid@ Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, I composite, perlite/urethane composite, wood fiber/polyisocyanurate composite. Base Sheet: — Two or more plies Type G2 or Type G3. Ply Sheet (Optional): — One or more plies Type G1. Membrane: — One or more plies "Ruberold@ Torch" (Smooth or Granule) or) Mop" (Smooth or Granule) or "Ruberold@ Mop Plus Granule." Surfacing: — "Karnak No. 97" applied at 11h to 3-gal/100-ft2 or gravel 8. Deck: NC Incline: 1/2 Insulation: — One or more layers perlite, glass fiber, 3A -in. minimu perlite/urethane composite, 11/2 -in. minimum. Base Sheet (Optional): — One or more plies Type G1 or Type G2 Membrane: — One or more plies "Ruberoid@ Torch" (Smooth or Mop" (Smooth or Granule) or "Ruberoid@ Mop Plus Granule." Surfacing: — Grundy "AL MB Aluminum Roof Coating" applied at 1 http://database.ul.com/cgi-bin/XYV/templateALISEXT/1 urethane, perlite/polyisocyanurate Torch Granule Plus" or "Ruberoid@ polyisocyanurate, urethane, perlite/polyisocyanurate composite, Type G3. rule) or "Ruberoid@ Torch Granule Plus" or "Ruberoid@ 2-gal/100-ft2. FU.R1306&ccnsho... 2/25/2014 TGFU.R1306 - Roofing Systems 9. Deck: C-15/32 Incline: 1/2 Page 2 of 2 Insulation (Optional): — One or more layers perlite, glass fiber, 3/4 -in. minimum, polyisocyanurate, urethane, perlite/polylsocyanurate composite, perlite/urethane composite, phenolic, 11h -In. minimum. Base Sheet: — One or more piles Type G2 "GAFGLAS@ #75 Base Sheet", or "Tri -Ply® #75 Base Sheet", hot mopped or mechanically fastened In place. Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6" hot mopped in place. Membrane: - "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual FR" or "Ruberoid@ Mop FR" or "Ruberoid@ EnergyCapm Mop FR." na (Optional): — "GAF Fibered Aluminum Coating" applied at llh-gal/100-191:2 or "GAF Weather Coat Emulsion" applied at 3- 10. Deck. C-15/32 / Incline: Ya aOptional): — Perlite, fiber glass polylsocyanurate, urethane or perlite/polyisocyanurate non ( composite. Base Sheet: — One or more layers Type G2 GAFGLAS@ #75 Base Sheet" or'Tri-Ply@ #75 Base Sheet" or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "TrI-Ply@ ra u ced Cap Sheet" hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place. Membrane: — "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual FR" or "Ruberold@ Mop FR" or "Ruberoid@ EnergyCap— Mop FR." http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TGFU.R1306&ccnsho... 2/25/2014