Loading...
MC-14-1088P Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSiP-216079 Permit Number: MC -5-14-1088 Scheduled Inspection Date: July 21, 2014 Permit Type: Mechanical - Residential Inspector: Perez, JanPierre Inspection Type: Final Owner: SZWED, LOGAN Work Classification: A/C Replacement Job Address: 1060 NE 95 Street Miami Shores, FL 33138 - Project: <NONE> Phone Number Parcel Number 1132050120040 Contractor: BLUE BREEZE AIR CONDITIONING AND HEATING Phone: 305-865-1220 Building Department Comments REPLACING EXACT CHANGE OUT 3 TONS Infractio Passed comments INSPECTOR COMMENTS False i Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-213621. CREATED AS REINSPECTION FOR INSP-213124. need 8' ladder & ref lock cap, need to seal ducts & fix drain pan Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. July 18, 2014 For Inspections please call: (305)762-4949 Page 18 of 23 Miami Shores VillageEDi Building Department MAY914 10050 N.E.2nd Avenue, Miami Shores, Florida 33138, Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 20 BUILDING PERMIT APPLICATION Permit Type: MECHANICAL JOB ADDRESS: Permit No. ff �a/�1 - Master Permit No. ri� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: I t 51®.S "®12_ -00 4 0 Is the Building Historically Designated: Yes NO Zone: OWNER: Name (Fee Simple Titleholder): L o A a -W% c �.J W_G Phone#: 3 bS—RSA — Q Address: I (> to C) J E am `� City: LAC-; State: 'IF L. Zip: 33 is% Tenant Email: CONTRACTOR: Company NamC&., C(1.?'Zlr_ ��B t- Phone#: Address: ii l l Sr City: h t State: !Vi Zip: �i Qualifier Name: t'il'x:1 -=0(2 ':p -["l A Phone#: 3P -S -%& 5; — 2— State Certification or Registration #: CAC 10(32,c' e, Contact Phone#: Email Address: of Competency #: DESIGNER: Architect/Engineer. Phone#: Value of Work for this Permit: $ "l oco Square/Linear Footage of Work: Type of Work: OAddress OAlteration ONew Mepair/Replace ODemolition Description of Work: TCIbx-Ek C!A l(. rte' Submittal Fee $ Permit Fee Scanning Fee $ Radon Fee $ V Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO/CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation bus commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant roust promise in good faith that a copy of the of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, certd copy of the recorded notice of commencement must be posted at the job site for the fast inspection which occurs seven (7) days the buil . permit is issued. In the absence of such posted notice, the nspecd l no approved and a reinspection fee will c ed Signature Signature Aeent r The foregoing insTrument was acknowledged before me this S,-4 day of , 20 N1 , by �oe,&,2. who is personally known to me or who has produced_ f,,J 0,A A I As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commissi APPROVED BY .1wWrp rulmm b1ft Of FbrWa Emilce Van Den Bergh W CaemissIM EE 195282 Expires 05102/2018 The foregoing instrument was acknowledged before me thisU day of m- , 20 _1 by who is personally known to me or who has produced _ dans Examiner Structural Review Revised 3/1212012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) identification and who did take an oath. NOTARY PUBLIC: Sig[ Prin My Zoning Clerk Miami Shores village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795 2204 Fax. (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet Multiple units on single sheets are not acceptable. Job Address (where the work Is being done): 1060 City: Miami Shores Village County: Miami Dade Zip Code: 7�-3 f -3 S ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ N0J�r ARHI Sheet Attached: YESJEr NO ❑ Contract Attached: YES UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER AHU or PKG. UNIT MODEL # 3 COND. UNIT MODEL # 1 &, JN i KW HEAT 10 VLj- IS NOM TONS AHU CU PKG 1 M.CA AHU CU PKG AHU CU PKG 2 M.O.P AHU CU PKG AHU CU PKG 3 VOLTS AHU CU PKG PKG UNIT / I PKG UNIT I I EER/SEER YES NO REPLACING DUCTS YES YES NO REPLACING THERMOSTAT YES YES NO NEW 4°CONCRETE SLAB ZMN YES NO NEW ROOF STAND YES Cy EEJ YES NO NEW RETURN PLENUM BOX UW NO 1. Minimum Circuit Ampaciiy (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breake r �Size): CL f 3. Voltage of Circuit (208/2401480): Q & 0 4. Size Disconnecting Mean; Contractor's Company Name: Phone: S& .�'12— State State Certificate or Registration N. Certificate of Competency NLy. Signature Date: �' One Hour Air Conditioning & Heating #156 655 NW 118' Street Miami, FL 33168 Ph. 305-865-1220, Fax. 305-865-7779 Licensed and Insured CAC1813298 www.onehourairmiami.com Proposal submitted to: Logan Szwed 1060 NE 95 Street Miami Shores, FL 33138 Job type: Replace A/C system Date: May 28, 2014 WE PROPOSE TO FURNISH AND INSTALL THE FOLLOWING: • Furnish and install new Air Conditioning Unit • Adjust Air supply plenum to new AC layout • Existing Digital Thermostat • Star up and system operating check up. • All labor, materials & supervision Comfort System (2) Tons Split AC unit by OHACBasic .Package Variable Capacity Control Single Speed Comp Variable Speed Air Handler No SEER (Super Hi -Efficiency) 14 s, ,Y.4,,, 10 s. _ P , Safety One Packages (1) safety flow switches to help prevent water leak, expand existing return grill to the hallway. sound package, hurricane tie downs,_ mechanical attachments. New Environmental refrigerant 5 Yes Dehumidification Good Inside Unit Air Handler Insulated Florida Power Light rebate -$210 Existing Digital Thermostat with build in time delay Digital Factory Rebate -$150 Dispose existing AC unit as per EPA regulations Yes Final Investment with Taxes after all rebates $3,987. Exclusions ✓ Any/ All dry wall, painting, plastering. ✓ Any/All electrical work ✓ Any/All demolition non related to AC system ✓ City Permit fees @2010 One Hour Air Conditioning All equipment and material will be new, and installed according to accepted engineering practice. Any alteration or deviation from the above proposal and bid documents will be executed only upon change orders, and will become an extra charge. The warranties provided herein are in lieu of all other warranties or obligations expressed or implied, and it neither assumes nor authorizes any other person to assume for it any liability concerning the sale of this equipment. All warranty service calls will be made during normal working hours Monday through Friday. Emergency service calls made outside of normal working hours will be charged at the standard over -time rate. It is agreed that the seller shall not be responsible for any loss, damage, or delay caused by malfunctioning equipment, acts of government, fire, explosion, theft, rain, floods, water damage, strikes, war, civil commotion, malicious mischief, acts of God, any cause beyond its control, or in any event for consequential damages. Ownership of the above equipment and materials shall remain in the seller's name and title is retained until payment is made in full. In the event purchaser does not pay within the time and manner as set forth below, the seller, at its option, may remove said equipment. The purchaser will sustain costs incurred from non-payment of billing including court costs and attorney's fees. Purchaser agrees to a late payment fee of $25.00 per occurrence and 1.5% per month to be added to unpaid balances 30 days past due. One Hour Air Conditioning may withdraw this proposal if not accepted within 30 days. Accepted for purchaser (Principle/Owner Signature) Accepted Conditioning Mil Matias Ti Print Name/Title One Hour Air Conditioning & Heating 655 NW 118' Street Miami, FL 33168 Ph. 305-865-1220 - Fax. 305-865-7779 www.onehourairmiami.com May 28, 2014 Date 28, 2014 Date Certificate of Product Ratinas AHRI Certified Reference Number: 4525743 Date: 5/27/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 13AJN36 Indoor Unit Model Number: RBHP-21+RCHL-36A1 Manufacturer: RHEEM SALES COMPANY, INC. Trade/Brand name: RHEEM, RUUD, WEATHERKING Series name: RHEEM 13AJN SERIES Manufacturer responsible for the rating of this system combination Is RHEEM SALES COMPANY, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, Independent, third party testing: * Ratings followed by an asterisk (*) Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) fisted on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and Am confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrldlrectory.org, click on 'Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed at bottom right. g ©20JA Air -Conditioning, Heating, and Refrigeration Institute , j •: °, s Project Summary Entire House Blue Breeze One Hour Air Conditioning & Heating 90 ., Project Information For: Logan Szwed 1060 NE 95 Street, Miami Shores, FL 33138 Job: Date: By: Maths Notes: REPLACE EXISTING AC UNIT 3 TONS --.. 4Desi n Information Weather: Miami, Int'I AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 50 OF Inside db 70 OF Design TD 20 OF Heating Summary 0.23 Equiv. AVF (cfm) Structure 14684 Btuh Ducts 4146 Btuh Central vent (19 cfm) 425 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 19255 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Efficiency Heating input. Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 1260 cfm 0.067 cfm/Btuh 0.00 in H2O Outside db Heating Cooling Area (W) 1209 1209 Volume (ft3) 9672 9672 Air changesthour 0.45 0.23 Equiv. AVF (cfm) 73 37 Heating Equipment Summary 56 Make 0.00 in H2O Trade 0.87 Model Efficiency Heating input. Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 1260 cfm 0.067 cfm/Btuh 0.00 in H2O Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Make Rheem Relative humidity 50 % Moisture difference 56 gr/Ib Sensible Cooling Equipment Load Sizing Structure 18280 Btuh Ducts 7156 Btuh Central vent (19 cfm) 1317 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24012 Btuh Latent Cooling Equipment Load Sizing Structure 1403 Btuh Ducts 1795 Btuh Central vent (19 cfm) 732 Btuh Equipment latent load 6850 Btuh Equipment total load Req. total capacity at 0.70 SHR 30862 Btuh 2.9 ton Cooling Equipment Summary Make Rheem 1260 Trade Rheem 13AJN Series Air flow factor Cond 13AJN36 cfm/Btuh Coil RBHL-21+Rohl-36A1 0.00 Efficiency 14 SEER Sensible cooling 24220 Btuh Latent coaling 10380 Btuh Total cooling 34600 Btuh Actual air flow 1260 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.87 BoWdallo values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. � . wngl�tsoft Right -Suite Residential 6.0.110 RSR39400 2014 -May -2809:33:52 +A C:\My Documents\Wrightsoft HVAC\Template\FPL\3 Tons AC_Rheem 14 SEER.rrt Calc = MJ8 Orientation Page 1