Loading...
WS-14-1171 (2)Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-216597 Scheduled Inspection Date: July 31, 2014 Inspector: Naranjo, Ismael Owner: MIAMI PROPERTY SOLUTIONS LLC, AMARA' TC 00^0cov f11 1I1rIAAIC 1 1 f% Job Address: 122 NW 110 Street Miami Shores, FL 331684321 Project: <NONE> Contractor: COLBERT INC Builaing Department comments REPLACE SINGLE GARAGE DOOR Permit Number: WS -6-14-1171 Permit Type: Windows/Shutters Inspection Type: Final Work Classification: Garage Door Phone Number (786)344-6463 Parcel Number 1121360030100 INSPECTOR COMMENTS False Phone: (786)344-6463 Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-216073. CREATED AS REINSPECTION FOR INSP-213662. No access, no one home 07-25-14 Failed ❑ No access, no one home, also note that a permit is required to replace the damage sidewalk in front of the property. Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. July 30, 2014 For Inspections please call: (305)762-4949 Page 18 of 26 Miami Shores Village Building Department L 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: j LZ 01 0• l 107N N JUN 0 5 2014 FBC 2016 Permit No. Master Permit NoW_ S I 2'1 ROOFING city. Miami shores Casty: Miami Dade Tip: FolioiTarcel#. Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): A -AA" � 811 `% �a' ll`c°5 �� Phone# JX' 9®) Y®Yr Address: 19 0 A%- d!5• Il f S/ City: TenantA,essee Name: Email: State: Zip: 35/ (0 / CONTRACTOR: Company Name: daLl M SNC - Phone#: % i% 3 YY_-/, 5_1,3 Address: a� k qf Av- a, _%y P1#T_t'= City: Qualifier Name: 1 f. �a � ZZ �" Phone#: IA., 3&4 JVa State Certification or Registration *.C, CC l S" i Z c% , Certificate of Competency #: Contact Phone#: _ 7�0 3 �/� - 6 YG Email Address: DESIGNER: Architect(Engineer. Phone#: Value of Work for this Permit: $ -7 at) • e- 49 SquardLinear Footage of Work: Type of Work: ❑Addition OAlteration ONew Wlfi rlReplace ❑Demolition Description of Work: f� 1-e 6 �i D clean o41 Color thou tile: Submittal Fee $ ' tel`/ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name ('if applicable) Mortgage Lender's Address City Tip Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EViPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITS YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be pr �.- en -f be charged Signa:e Signature or Agent tractor The foregoing instrument was acknowledged before me this _JL The foregoing ' t was acknowledged before me this .3 day of., 20 Jam, by li 'GIF.'Y�— day of �% 20 %�, by 916 g &�A t who_a11v rn.om., ro me or who has produced who is finally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. Structural Review Clerk (Revised 3/12i2012)(Reviwd 07/1INo7)(ReWi 06110/ ")Amised 3/15/09) Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner - Workers' Compensation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption. In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company. Therefore, you may be personally liable for the worker compensation injuries of any person allowed to work under this permit Please check with your insurance carrier since most property insurance policies DO NOT cover this type of liability. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. er State of Florida ) County of Miami -Dade Sworn to aPd subscribe day of itit rr Z. By (SEAL) Tvge of Identification gyre me Ois , 20 /. ;- Maxine Y Comer. My rommission EE 839239 Contractor County of Miami -Dade ) Sworn tocrib a su s day of , 0 of Identification before meA4 _ / 7 Notary public State of Flora Commission EE 839239 ires 09/30/2016 '4� CERTIFICATE OF LIABILITY INSURANCE 5/19//22014rn THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT. It the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the term and conditions of the policy, certain poles may require an endorsement A statement on this certificate does not confer rights to the certificate holder In Ihlu of such endorsema s). PFODUM The Contractors Choice Agency PO Boa 13645 Chandler AZ 85248 =ACT Jon Rock PHONE (800) 918-3584 F (877) 684-9951 Jon@ngiasuranc�oniiae.cae INUMMMAIFFORIMINGCOVERAGE NAIC S INSURERA-Yreferred Contractors Insurance 12497 INSURED Colbert Inc. 3645 NW 57th Place Vi a Gardens FL 33166 INIRn m B: INSURERC• D, INSURERE: INSURER F. COVERAGES CERTIFICATE NAM ER -=251616553 REVISION NUMBER2 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPEOFIIIRANCE EFF POLICY L191IiS A GENERAL LABILITY R COMMERCIAL GENERAL LIABILITY CLAIMS-VADE ® OCCUR C5o26-BCh521719 /15/2014 /15/2015 EACH OCCURRENCE $ 1,000,000 PREM $ 50,000 MEQ EXP (Aar one per„) $ 5,000 PERSONAL s ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 1,000,000 GEWL AGGREGATE LNIT APPLIES PER: X POLICY � JECT LOC PRODUCTS - COMPIOP AGG $ 1,000,000 $ AUTE uABILmr ANY AUTO ALL OWNED AUTOS ALIT MED HIRED AUTOS AUTOS COUB94ED MAE LIMIT BODILY INJURY (Per pmson) $ BODILY INJURY (PerawIddeM $ � O� $ UA8 _[dOCCUR EXCESS LIAR CI A MS -MADE EACH OCCURRENCE $ AGGREGATE $ WORIUMCOMPENSATM AND EMPLOYERS• LUUMM YIN ANY PROPRIETY El ED?N OFRCERNABMER(�, d •wy In amq DESCPoPTION OF OPERATIONS 0a. / A 1fi� STA - OTH tU� E.L. EACH ACCIDENT $ E.L. DISEASE - EA EM $ E.L. DISEASE - POLICY LIMIT $ 1 L MMCVMnMCWOMMMMIUMMMIVEH=M OUtm 6 ACORD 101, AddMonid Reaaarlw Sefiedule, B mmspacetsmqubeM CGC1512466 (305)756-8972 felicianoj@m1am:ishoresvill Miami. Shores Village 10050 ME 2nd Avenue Miami Shores, FL 33138 ACORD 25 (2010105) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE VALL BE DELIVERED IN ACCORDANCE WRTH THE POLICY PROVISIONS. Vol III„l.:rc44- -: A Rock/JON A�a/4 ` IN3025rgmrmi m Tina AP.f1Rr1 nanm ami Innn seas ennT@taeaeur ,task$ of ArYWn �. _=: _®®_ www.skyrockeng.com - r CITY JUL 0 0 2014 STRUCTURAL CALCULATIONSCOPY FOR GARAGE DOOR REPLACEMENT AT 122 NW 110th. STREET MIAMI SHORES, FL. 33161 f, PREPARED BY: AIMEE RODRIGUEZ, PE. LICENSE No. 69701 CA No. 29652 7, Phone: 786.285.7157 Fax: 305.258.3345 Email: aimee@skyrockeng.com rA MECAWind Version 2.1.0.6 per ASCE 7-10 Developed by MCA Enterprises, Inc. Copyright 2014 t,,wo.,.mecaenterrrises. com Date 7/7/2014 Project No. Company Name Designed By Address Description City Customer Name : State Proj Location : File Location: C:\WORK\MY PROJECTS\2014\122 NW 110 St\calc\wind.wnd Directional Procedure Simplified Diaphragrm Building (Ch 27 Part 2) All pressures shown are based upon ASD Design, with a Load Factor of .6 Basic Wind Speed(V) = 175.00 mph 21.19 psf pl: Structural Category = II 12.95 Exposure Category = C Windward wall pressure acting uniformly outward = Natural Frequency - N/A psf Flexible Structure = No p0-pl = Importance Factor = 1.00 Kd Directional Factor = 1.00 Damping Ratio (beta) = 0.01 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 3 : 12 Slope of Roof(Theta) = 14.00 Deg Ht: Mean Roof Ht = 15.00 ft Type of Roof = Hipped RHt: Ridge Ht = 15.00 ft Eht: Eave Height = 15.00 ft OH: Roof Overhang at Eave= 2.00 ft Roof Area = 158.00 ft^ 2 Bldg Length Along Ridge = 15.50 ft Bldg Width Across Ridge= 12.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gust1: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc*(33/Zm)^0.167 - 0.23 Lzm: 1*(Zm/33)^Epsilon = 427.06 ft Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.95 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.90 Gust Factor Summary Not a Flexible Structure use the Lessor of Gust1 or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Topographic Adjustment 0.33*z = 4.95 Kzt (0.33*z): Topographic factor at elevation 0.33*z = 1.00 Vtopo: Adjust V per Para 27.5.2: V * [Kzt(0.33*z)]^0.5 = 175.00 mph Net Wind Pressures on Walls (Table 27.6-1) Wall Pressures do not include effect of internal pressure MWFRS-Wall Pressures for Wind Normal to 12 ft wall L/B - 1.29 ph: Net Pressure at top of wall (windward + leeward) - 37.23 psf p0: Net Pressure at bottom of wall (windward + leeward) - 37.23 psf ps: Side wall pressure acting uniformly outward = .57 * ph = 21.19 psf pl: Leeward wall pressure acting uniformly outward = .35 * ph= 12.95 psf pwh: Windward wall pressure acting uniformly outward = ph-pl = 24.28 psf pw0: Windward wall pressure acting uniformly outward = p0-pl = 24.28 psf 9 MFRS -Wall Pressures for Wind Normal to 15.5 ft wall L/B ph: Net Pressure at top of wall (windward + leeward) - p0: Net Pressure at bottom of wall (windward + leeward) _ ps: Side wall pressure acting uniformly outward = .54 * ph = pl: Leeward wall pressure acting uniformly outward = .38 * ph= pwh: Windward wall pressure acting uniformly outward = ph-pl = pw0: Windward wall pressure acting uniformly outward = p0-pl = See ft 27.&2 f" PanWt VYInd Roof PrOmM See Table 27.6-2 Mean mof he. 0.77 38.70 psf 38.70 psf 20.90 psf 14.71 psf 23.99 psf 23.99 psf Net Wind Pressures on Roof (Table 27.6-2): Exposure Adjustment Factor = 1.000 Zone Load Casel Load Case2 ---- psf ---------- Psf ---------- 1 -35.37 5.12 2 -24.35 -7.17 3 -36.05 .00 4 -32.18 .00 5 -26.37 .00 Note: A value of 10' indicates that the zone/load case is not applicable. Hipped Roof Roof Overhang Loads (Figur® 27.6-3): Load Case 1: Povh1: Overhang pressure for zone 1 Povh3: Overhang pressure for zone 3 Load Case 2• Povhl: Overhang pressure for zone 1 Povh3: Overhang pressure for zone 3 Roof 0* . _ _ tbl Zo 1 of I as applicabk- Pf -26.53 psf -27.03 psf 3.84 psf .00 psf MECANInd Version 2.1.0.6 ASCE 7-10 Developed by MECA Enterprises, Inc. Copyright 2014 ww,,.mecaente-,prises.coin Date : 7/7/2014 Project No. Company Name : Designed By Address Description City Customer Name State Proj Location File Location: C:\WORK\NY PROJECTS\2014\122 NW 110 St\calc\wind.wnd El Elip Roof 7 < 0 <- 27 Wind Pressure on Components and Cladding (Ch 30 Part 1) All pressures shown are based upon ASD Design, with a Load Factor of .6 Width of Pressure Coefficient Zone "a" = 3 ft Description Width Span Area Zone Max Min Max P Min P -------------------------------------------------------------------------- ft ft ft^2 GCp GCp psf psf GARAGE DOOR 7.00 9.00 63.0 4 0.86 -0.96 41.48 -45.48 GARAGE DOOR 7.00 9.00 63.0 5 0.86 -1.12 41.48 -51.82 Khcc:Comp. & Clad. Table 6-3 Case 1 = 0.85 Qhcc:.00256 *VA 2*Khcc*Kht*Kd = 39.93 psf EXISTING DOOR TO REMAIN EXISTING \ TIE COLUMN GC. VERIFY WINDOW/DOOR WIND PRESS. +42.0 PSF (*) -52.0 PSF (*) REMOVE AND REPLACE EXISTING GARAGE DOOR FOR A NEW 1081A 84" STEEL PAN SECTIONAL GC. VERIFY ON FIELD GARAGE DOOR BY 1# 51N GROUTED CELL CLOPAY BUILDING AT EACH SIDE OF PRODUCTS COMPANY. --\ EXIST. OPENING NOA No. 12-0105.01 12'-U' FLOOR PLAN N.T.S. CAIS f ING WINDOW TO REMAIN LOi O I I EXISTINGTIE COLUMN GC.VERIFY GC. VERIFY ON FIELD 1# 51N GROUTED CELL AT EACH SIDE OF EXIST. OPENING I LEGEND: (�} ALL PRESSURES SHOWN ARE BASED UPON ASD DESIGN, WITH A LOAD FACTOR OF 0.6 EXISTING j WIINDOW TO REMAIN � GARAGE i EXISTING \ TIE COLUMN GC. VERIFY WINDOW/DOOR WIND PRESS. +42.0 PSF (*) -52.0 PSF (*) REMOVE AND REPLACE EXISTING GARAGE DOOR FOR A NEW 1081A 84" STEEL PAN SECTIONAL GC. VERIFY ON FIELD GARAGE DOOR BY 1# 51N GROUTED CELL CLOPAY BUILDING AT EACH SIDE OF PRODUCTS COMPANY. --\ EXIST. OPENING NOA No. 12-0105.01 12'-U' FLOOR PLAN N.T.S. CAIS f ING WINDOW TO REMAIN LOi O I I EXISTINGTIE COLUMN GC.VERIFY GC. VERIFY ON FIELD 1# 51N GROUTED CELL AT EACH SIDE OF EXIST. OPENING I LEGEND: (�} ALL PRESSURES SHOWN ARE BASED UPON ASD DESIGN, WITH A LOAD FACTOR OF 0.6 MIAMI-DADE COUNTY o PRODUCT CONTROL 99MON DEPARTMENT OF PERMITTEKG, ENVIRONMENT. AND RI;GUTATORV 11805 SRS 26 Sftc% Room 208 AFFAIRS (PENA) Miami, Florida 33175-2474 BOARD AND CODE ADMINM T`RATION DIVISION T (786) 315-2590 F (796) 315-2594 NOTICE OF ACCEPTANCE (KOA) www.mlamldadtA3ftW Clopay BuUftg Prmlatds Company 8585 D m Boulevard Masan, OH 43040 SCOPE: This NOA is being issued under the applicable rules and regulstiore governing the use of construction materials. The documentation submitted Its been reviewed and accepted by Miami --Dade County PERA Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date "ad below. The Mei-Dade County Product Control Section (In Miami Dade County) and0t►r the AIU tiro mm adw &= Miami Dade County) reserve the right to have this product or material tested for quality assurance per. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately mvolor., modify, or suspend the use of such product or material within their jprlsdictim P13RA reservies the right to revokelbls acceptance, if it is determined by Miami -Dade County Product Control Section did this product or material Wis to meet the requirements of the applicable building code. This product is approved as described harem, and has been dead to cmmply with the Florida Building Code, including due High Velocity Hurricane imine. DESCRIPTION: Steel Pan Sectional Garage Door up to 9'-0" Wide with Impact Litcs APPROVAL DOCUMENT: Drawing No. IGM7, titled "Side Car WS Pan Door with Ind Resistant Limes", dated 10i23i2006, with last revision dater 1211512DI 1, sheet 1 of 1, prepared by Clopay Building Products Company, signed and sealed by Scott Haub^ P.E., beating the Miami Dade County Product Control renewal stamp with the Notice of Acceptance number and exon date by the Miami -Dade County Product Control Section. MHSMA IMPACT RATING: Iwrge and Sma® Awe Impact Rmistant LABELING: A parmameo bW W& ft numubwaWs turas or logo, nunufacturing address, model number, the positive and negative design pressure rating, indices impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading 'Miami -Dade County Product Control Approved' is to be located an the dm's side triode, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in tate applicable building code negatively affectingthe pefformance of this product. TERMINATION of this NOA will oar afiuu the expiration tate or if theme has been a revision or change in the materials, use, and/or manufachne of the product or process. Misuse of this MA as an endorsement of any product, for sales, advertising or any other purposes stall scally terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. LBUTATION: This gproval requires the aamillictuver to test all coils used to fabricate door panels under this Notice of Acceptance. A minimum: of 2 specimens shall be cut from each cod and tensile tested according to ASTM E-8 by a Miami Dade County approved laboratory selected and paid by the mamrfaatmer. Every 3 months, four times a year, the manufacturer shall mail to this office: a copy of the teat reports with confirmation that the specimen were selected from coils at the maraffactorer produc d nu des and a notarized statement from the mam>factuurer that only coils with yield strength of 30,600 psi or more shall be used to make door panels under this NOA. AD : The NOA number primed by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for mRxgd.w at tine job site at the reqs of the Building Official. This NOA renews NOA # 07-112W* and consists ofthis page 1 and evidence page E-1, as well as approval document mentioned above. The submittal documentation was reviewed by Carlos AL Utrera, P.E. NOA No 12-0105.01 Expiration Date; February 21, 2017 Approval Date: March 1, 2012 Page 1 A. DRAWINGS 1. Drawing No. 103547, tided "Single Car WS Pan Door with Impact Resistant Lines", dated lof2312006, with last revision dated 1 2/1 5120 1 1, shed 1 of 1, prepared by Clopay Building Products Company, signed and sealed by Sett Hamilton, P.E. B. TESTS "Sub;n&W u rNOA # M-1107.02" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 2) Large Missile Impact Test per FBC, TAS 201 3) Cyclic Wind Pressure Loading per FBC, TAS 203 Wow with marked -up drawings and illation diagram of Clopay 9'x 8' 24 ga. Steel Door, Model 94W8, prepared by American Testing Lab, Inc., Test Report No. ATLNC 1008.01-07, dated 1110512007, silted wkd surfed by David W. Job =% P.T. "Subm&ted mtdaNOA # 06-110102" 2. Test report on Accelerated d Weafl=ft Using Xenon Are Light Apparatus, per ASTM G 155, Test Report No 1M -)6-A00% premed by Hurricane Pagmearing and Testing, Inc, dated 11108f1006, signet and sealed by Rafael K Droz-Sade, P.E. 3. Tensile Test on GE Levan SLX2432T, per ASTM D 638 and ASTM E 8, Test Reports No. Il -*-T566 and SET!4%-T634, prepared by Hwitcae Engineering and Testing, Inc., dated 07/14fM and 11/tW006, signed and scaled by Rafael R Droz-Sada, P.E. 4. Test report on Self -Ignition Temperature (ASTM D 1929), Rate of Burn (ASTM D 63 5) and Smoke pity (ASW D 2843 Test Report No. ETC -@6 1824-174411.0, dated 05/26/2006, signed and sled by Joseph L. Doldan, P.E. C. CAIXIULMONS "Subusi*d under NOA # 06-1107.02" 1. Anchoring calculations prepared by Clopay Building Products Company, dated l 012412006, signed and scaled by Scott Hamilton, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Eamonment, and Regulatory Affairs (PERA) E. MATERIAL CYRMCATIONS 1. Tensile tests on Painted Ems Steel, per ASTM E 8, Tea Reports No. HET14K.T596, T597 and T598, dated 08/2412006, signet by Rafael E. Droz %da, P.E. 2. Salt Spray RVosure Tea Report No. 3010-"-63M, pied by Stork Twin City Testing Corporation, dated OU26/2005, signed by John D. Lee, P.E. F. STATEMENTS 1. Statement letter of code conformance with 2007 and 2010 FBC, issued by Clopay Building Products Company, dated 02117/2012, signed and sealed.by Scott Hamilton, P.E. 2. Statement letter of no financial interest muead by Clopay Building Products Company, dated 01/04/2012, signed and sealed by Smit Hamilton, P.E. �y�312v12 Carlos K Utrera, P.E. Product Control Examiner NOA No 12-0105.01 >xpiration Date: February 21, 2017 Approval Date: March 1, 2012 �-1