RF-14-1547Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)'756-8972 Inspection Number: INSP-217296 Scheduled Inspection Date: August 08, 2014 Inspector: Naranjo, Ismael Owner: , Job Address: 10450 NE 5 Avenue Miami Shores, FL 33138 - Project: <NONE> Contractor: ACE PROPERTY SERVICES CORP Building Department Comments REROOF REAR FLAT ROOF Passed Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Permit Number: RF -7-14-1547 Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1122310150240 Phone: 305-598-1700 INSPECTOR COMMENTS False Inspector Comments CR TE AS REINSPECTION FOR INSP-216142. Supply uplift test August 07, 2014 For Inspections please call: (305)762-4949 Page 19 of 31 W BUILDING PERMIT APPLICATION Miami Shores e Villa g Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 JUL 18_2014 FBC20(0 ( Master Permit No.R E— b �— ( l' Sub Permit No. ❑BUILDING M ELECTRIC 0 ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL F-1 PLUMBING F-1 MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP P CONTRACTOR DRAWINGS JOB ADDRESS: f ® q S® w64 5 1� City: Miami Shores Countv:aw Miami Dade zip: 3313S, Folio/Parcel#: // —29!31 - of S- �"Lc10 Is the Building Historically Designated: Yes NO L --'- Occupancy Type: Load: Construction Type: �iFlood Zone: BFE: FFE: -Frnm / f-4 City: �UAIAA4 6 �� State: F1 Zip: 33l G,Ci Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: ACE PROPERTY SERVICES CORP Address: 10871 SW 188 ST #8 hone#: 305-598-1700 City: MIAMI State: FL Zip: 33157 Qualifier Name: CARLOS PULLES Phone#: 786-443-2231 State Certification or Registration #: CCC 058229 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 52",00, Square/Linear Footage of Work: S-00 L1 Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/ eplace ❑ Demolition A AA Description of Work: Specify color of color thru tile: �. Submittal Fee $ E Permit Fee $ Q -M CCF $ CO/CC $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ _ (Revised02/24/2014) DBPR $ Notary $ Double Fee $ Bond $ t::?C�0- OD TOTAL FEE NOW DUE $ _-4 q. i Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. � Signature � � Signature #NER or AGENT CONTRACTOR The fore oing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this _ day of 20 by I --YA4N. day of 20 by 51 it I MeMe.6 P/✓ , who is personally known to S AU11188 who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Print: d '1i VI.P. Seal: VEGA-PULLES MISSION # EE182225 [e*-/N:-L:1BERTjAD =, May 26, 2016 i APPROVED BY (Revised02/24/2014) identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: ,Plans Examiner Structural Review piwin'llf MY COMMISSION # EE211617 EXPIRES June 26, 2016 Zoning Clerk a 11A t ur rLUKIWA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD ,�1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 PULLES, CARLOS SANTOS ACE PROPERTY SERVICES CORP 10871 SW 188TH ST #8 MIAMI FL 33157 Congratulationsl With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Flondit economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myflorldalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's Initiatives. - Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your Customers. Thank you for doing business in Florida, and congratulations on your new license! DETACH HERE RICK SCOTT, GOVERNOR (850) 487-1395 STATE OF FLORIDA DEPARTMENT OF BUSINESS ANC 3 Q PROFESSIONAL REGULATION CCCO58229 ISSUED: 05/29/2014 CERTIFIED ROOFING CONTRACTOR PULLES, CARLOS SANTOS ACE PROPERTY SERVICES CORP IS CERTIFIED under the provisions of Ch.489 FS. ExpVation date : AUG 31, 2018 1.140528=187i KEN LAWSON, SECRETAR' STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD LICENSE NUMBER 1.: The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 PULLES, CARLOS SANTOS ACE PROPERTY SERVICES CORP 10p871 SW 188 ST #8 MIAMI FL 33157 ISSUED: 05/29/2014 DISPLAY AS REQUIRED BY LAW SEQ# L1405290001678 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Property Address: ! 01456 ofe a 5 Avl-c . Roofing Permit Number. Dear Building Official: I st6,v_ �i e c:�l e )-- certify that I am not required to retrofit the roof to wall connections of my building because: V11he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signat a Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Swom to and subscribed before me this i WAA'\ \ day of l I 01-i 2(714= LIBERTAD VEGA-PULLES_ Notary Public, Sate of Florida at Large t t ' ��'�`''- �r o�ssloxu�18� onws�' :May 26, 2016 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,00. , and the budding was not oonstruded with FBC nor a SFBC. Then you must provide a building application from a General contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21009 Property Sear&, Application - Miami -Dade County 7/17/14 6:34 PM 0 """FFI E F T E PRA"PERTY APPRAlb"ER C 0 H Summary Report Property Information Folio: 11-2231-015-0240 Property Address: 10450 NE 5 AVE < Owner REALTY INVEST GRP OF FLA Mailing Address 10450 NE 5 AVE MIAMI SHORES, FL 33138-2040 Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,355 Sq.Ft Living Area 2,112 Sq.Ft Adjusted Area 2,206 Sq.Ft Lot Size 8,625 Sq. Ft Year Built 1953 Assessment Information Previous 20141 20131 2012 Year 2014 2013 2012 Land Value $140,036 $104,836 $77,656 Building Value $134,610 $134,610 $150,394 XF Value $4,644 $4,697 $5,134 Market Value $279,290 $244,143 $233,184 Assessed Value $268,557 $244,143 $233,184 Benefits Information Benefit Type 2014 2013 2012 Non -Homestead Cap Assessment Reduction 1 $10,733 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIRROR LAKE SUB PB 56-15 LOT 24 LOT SIZE 75.000 X 115 OR 17582-4080 0397 1 COC 22817-4570 10 2004 1 Generated On: 7/17/2014 Taxable Value Information Previous 20141 20131 2012 County Exemption Value $0 $01$0 Taxable Value $268,557 $244,143 $233,184 School Board Exemption Value $0 $0 $0 Taxable Value $279,290 $244,143 $233,184 City Exemption Value $0 $0 $0 Taxable Value $268,557 $244,143 $233,184 Regional Exemption Value $0 $0 $0 Taxable Value $268,5571 $244,143 $233,184 Sales Information Previous Price OR Book- Qualification Description Sale Page 10/01/2004 $520,000 22817-4570 2008 and prior year sales; Qual by exam of deed 03/01/1997 $154,000 17582-4080 2008 and prior year sales; Qua] by exam of deed 10/01/1993 $138,000 16106-1489 2008 and prior year sales; Qua] by exam of deed nQ/n9 /1 QR7 8113 nnn 1 AA97-1 QR9 2008 and prior year sales; Qual by exam http://www.miamidade.gov/propertysearch/index.html#/report/summary Page 1 of 2 Propgrty-Search Application - Miami -Dade County 7/17/14 6:34 PM F--,- _.*-,---I .,,... '___lofdeed I The Office of the Properly Appraiser is continually editing and updating the tax roll. This website may not reflect the most current Information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at httpJ/www.miamidade.govfinfo/disciaimer.asp (http:/ www.miamidade.govfinib/disrJaimer.asp) Version http://www.mlamidade.gov/propertysearch/index.html#/report/summary Page 2 of 2 2014 FLORIDA LIMITED LIABILITY COMPANY ANNUAL REPORT DOCUMENT# L04000065593 Entity Name: REALTY INVESTMENT GROUP OF FLORIDA, LLC Current Principal Place of Business: 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Current Mailing Address: 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 US FEI Number: 20-1605127 Name and Address of Current Registered Agent: KUNSOLLLC 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 US FILED Jan 27, 2014 Secretary of State CC2478212763 Certificate of Status Desired: No The above named entity submits this statement for the purpose of changing its registered office or registered agent, or both, in the State of Florida. SIGNATURE: SIBILA MENECIER 01/27/2014 Electronic Signature of Registered Agent Date Authorized Person(s) Detail: Title MGR Name KUNSOL LLC Address 17070 COLLINS AVE 262 City -State -Zip: SUNNY ISLES BEACH FL 33160 I hereby certify that the information indicated on this report or supplemental reporNs true and accurate and that my electronic signature shall have the same legal effect as if made under oath; that I am a managing member or manager of the limited liability company or the receiver or trustee empowered to execute this report as required by Chapter 605, Florida Statutes; and that my name appears above, or on an attachment with all other like empowered. SIGNATURE: SIBILA MENECIER MGR 01/27/2014 Electronic Signature of Signing Authorized Person(s) Detail Date Detail by Entity Name Florida Limited Liability Company REALTY INVESTMENT GROUP OF FLORIDA, LLC Filing Information Document Number FEI/EIN Number Date Filed State Status L04000065593 201605127 09/03/2004 FL ACTIVE Principal Address 17070 COLLINS AVE 262 , SUNNY ISLES BEACH, FL 33160 Changed: 04/24/2012 Mailing Address 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Changed: 04/24/2012 , KUNSOL LLC 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Name Changed: 01/27/2014 Address Changed: 04/24/2012 , Authorized Person(s) Detail Name & Address Title MGR KUNSOL LLC 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Page 1 of 2 http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetaillEntityName/flal-10... 7/15/2014 Detail by Entity Name Annual Reports Report Year Filed Date 2012 04/24/2012 2013 04/2512013 2014 01/27/2014 Document Images Page 2 of 2 01/27/2014 — ANNUAL REPORT View image in PDF format 04/25/2013 — ANNUAL REPORT View image in PDF format—] 04/24/2012 — ANNUAL REPORT View image in PDF format 04/18/2011 — ANNUAL REPORT View image in PDF format 03/19/2010 -- ANNUAL REPORT View image in PDF format 04/02/2009 — ANNUAL REPORT view image in PDF format 05/0812008 — ANNUAL REPORT View image in PDF format 03107/2007 — ANNUAL REPORT View image in PDF format 01/19/2006 ANNUAL REPORT View image in PDF format 07/11/2005 ANNUAL REPORT View image in PDF format 02/07/2005 — ANNUAL REPORT View image in PDF format 09/03/2004 -- Florida Limited Liability view image in PDF format Copyright@ and Privacy Polldes State of Florida, Department of State http://search.sunbiz.orglInquirylCorporationSearchISearchResultDetaillEntityNamelflal-10... 7/15/2014 Detail by Entity Name Page 1 of 2 Florida Limited Liability Company KUNSOL LLC Document Number L13000163802 FEI/EIN Number 90-1029475 Date Filed 11/22/2013 State FL ' Status ACTIVE Effective Date 11/22/2013 Principal Address 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Changed: 01/27/2014 Mailing Address 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Changed: 01/27/2014 Reglstered Agent Name & Address MENECIER, SIBILA 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Address Changed: 01/27/2014 Authorized Person(s) Detail Name & Address Title MGR MENECIER, SIBILA 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 http://search.sunbiz.orglInquiry/CorporationSearcblSearcbResultDetaillEntityNameIflal-11... 7/15/2014 Detail by Entity Name Annual Reports Report Year Filed Date 2014 01127/2014 Page 2 of 2 01/27/2014 -- ANNUAL REPORT View image in PDF format 11/22/2013 -- Florida Limited Liability View image in PDF format Convriaht O and Privacy Polities State of Florida, Department of State http://search. sunbiz.orglInquiry/CorporationSearch/SearchResultDetaillEntityName/flal-11... 7/15/2014 2014 FLORIDA LIMITED LIABILITY COMPANY ANNUAL REPORT DOCUMENT# L13000163802 Entity Name: KUNSOL LLC Current Principal Place of Business: 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 Current Mailing Address: 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 US FEI Number: 90-1029475 Name and Address of Current Registered Agent: MENECIER, SIBILA 17070 COLLINS AVE 262 SUNNY ISLES BEACH, FL 33160 US FILED Jan 27, 2014 Secretary of State CC9796508320 Certificate of Status Desired: No The above named entity submits this statement for the purpose of changing its registered office or registered agen4 or both, in the State of Florida. SIGNATURE: Electronic Signature of Registered Agent Date Authorized Person(s) Detail Title MGR Name MENECIER, SIBILA Address 17070 COLLINS AVE 262 City -State -Zip: SUNNY ISLES BEACH FL 33160 I hereby certify that the intormation indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under oath; that I am a managing member or manager of the limited liability company or the recetveror trustee empowered to execute this report as required by Chapter 605, Florida Statutes, and that my name appears above, or on an attachment with all other like empowered. SIGNATURE: SIBILA MENECIER MGR 01/27/2014 Electronic Signature of Signing Authorized Person(s) Detail Date Property Search Application - Miami -Dade County 7/17/14 6:36 PM Summary Report Property Information Folio: 11-2231-015-0240 Property Address: 10450 NE 5 AVE < Owner REALTY INVEST GRP OF FLA Mailing Address 10450 NE 5 AVE MIAMI SHORES, FL 33138-2040 Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,355 Sq. Ft Living Area 2,112 Sq.Ft Adjusted Area 2,206 Sq.Ft Lot Size 8,625 Sq.Ft Year Built 1953 Assessment Information Year 2014 2013 2012 Land Value $140,036 $104,836 $77,656 Building Value $134,610 $134,610 $150,394 XF Value $4,644 $4,697 $5,134 Market Value $279,290 $244,143 $233,184 Assessed Value $268,557 $244,143 $233,184 Benefits Information Benefit Type 2014 2013 2012 Non -Homestead Cap lAssessment Reduction 1 $10,733 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). (Short Legal Description MIRROR LAKE SUB PB 56-15 LOT 24 LOT SIZE 75.000 X 115 OR 17582-4080 0397 1 COC 22817-4570 10 2004 1 Generated On : 7/17/2014 Taxable Value Information Previous Price OR Book- Qualification Description Sale 2014 2013 2012 County $520,000 22817-4570 2008 and prior year sales; Qual by exam Exemption Value $0 $0 $0 Taxable Value 1 $268,557 $244,143 $233,184 School Board of deed 10/01/1993 $138,000 Exemption Value 2008 and prior year sales; Qual by exam $0 $0 $0 Taxable Value 1 $279,290 $244,143 $233,184 City Exemption Value $0 $0 $0 Taxable Value 1 $268,557 $244,143 $233,184 Regional Exemption Value $0 $0 $0 Taxable Value 1 $268,5571 $244,143 $233,184 Sales Information Previous Price OR Book- Qualification Description Sale Page 10/01/2004 $520,000 22817-4570 2008 and prior year sales; Qual by exam of deed 03/01/1997 $154,000 17582-4080 2008 and prior year sales; Qual by exam of deed 10/01/1993 $138,000 16106-1489 2008 and prior year sales; Qual by exam of deed no/n1 /1 QR7 o.1 11 nnn 1 Id'27-1 QF9 2008 and prior year sales; Qual by exam http://www.miamidade.gov/propertysearch/index.html#/report/summary Page 1 of 2 Property Search Application - Miami -Dade County 7/17/14 6:36 PM I ........ I ..._. --I I Of deed I The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Mlami-Dade County assumes no liability, see full disclaimer and User Agreement at hftoAwAy.miamidade.govAnib/discialmer.asp (httpJ/www.miamidade.govAnfo/disclaimer.asp) Version: http://www.miamidade.gov/propertysearch/Index.htm1#/report/summary Page 2 of 2 A" 1 Florida Building Code 2010 Edition High Velocity Hurricane Zone Uniform Permit Application Form Sw loonn ,C (Law Sloosd_&of Svdeim) Fill In Specific Roof Assembly Components and Identify Manufacturer of a component Is not used, IdsnW as NAI System Mamrtfacsumer a77 NOA No.• 19- 0424' O'q Design Wlrul Pressures, From RAS 128 or Calculations: Pmax1: -W-9 Pmax '7%/ % Pmw* '10$•0 Mex. Design Pressure, Frorn the Speoft NOA System: - S 2. S,p.s °ad Type: �" C -a 1 X (O Gaug&Thidutess: 3Y�a fO 9 i nke 1 t/ 2 c Slope: Anchorl6aee Sheet $ No of PIy(s): AnchodBese Sheet FasWmdBorK ft Material: Utsulatlon Bam lsy� Base Insulation Size and Thldtnew- — Base Insulation FestenedBonding Material: Top Insulation Layer �-- Top Insulation Sias area Thldmess Top Insulation FesterwAlonding Material: Bess Sheet(e) & No. of Ply($): I D Iii 190ft- m Base Sheet Fasten Material; —D -44a s A I T• � s -n A fo_S_ Ply Sheens)A No. of Piy(s): I PW JZ j4 Pfd j2V Ply Sheet FastenerMondkrg Material: Topi Aailw-Aee Coo k—ee� Top Ply Fastener/ Bonding Material: Ag Viral al- Surfadng: Fastener Spacing for Anchoditse Sheet A taohmant q FWd:.9--' oc 0 Lap, # Rows® / /•_oc Perimeter. • oc ® Lap, # Rows (� I° • oc Comer a ' oc 0 Lap, # Rowe --'L M.k' oo Number of Fasteners Per insulation Board A II n Field Pdrlrfet6rLZ Comer Illustrate Components Noted and Details as Applicable: Woodbloolting, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat. Cant Strip, Base Flashing. Cotmter- Flashing, Coping, Eta. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details VW Comply with RAS 111 and Chapter 16. NIA FT. ..4141 .•oo 4100 00400 • • 0000 • 000. • • q ".SPv i p H0B 14YIAwGbera�J ¢o' •41 41 FT. • 0.000' G -t I tc (o • ... • 'iAl ri 3x3 2b 90� 4141:•• •"� .41VM41►i z 4141••• • / d',A . • • so •41.40 41 .414041 ..4141 .•oo 4100 00400 • • 0000 • 000. • Florida Building Code 2010 Edition High Velocity Hurricane Zone Uniform Permit Application Foran Section D (Steep S, loosd Roof System) Roof Sym Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressus. if Appll bl (From RAS 127 or Calculations): P1 • P3: Maximum Design Pressure From the NOA Specific System): Method of the 77 men Steep oDed Roof System Description nderlayment: Roof Slope: :12 Ridge Ventilation? Mean Roof Heighb .. op e. Dose g Doa• as as ages .. . ego s L Spacing: .... Type . ...... .. Cap Sheet: ...... • s . • • oaf Covering: • • Type 8 Size Drip Edge: .. op e. Dose g Doa• as as ages Florida Building Code 2010 Edition High VelocitV Hurricane Zone Uniform Permit Application Form Section E (Til® Calculations) For Moment based tie systems, choon etffier Method 1 or 2. Compared do values for M,with the values from Mt. Uthe Mt values are greater than or equal to the Mr values, for each area of the roof, then the the attacbment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127' (PI: IL ) —MIF --W6 NOA 1* (P=: 11 a ,_1— Mw - M,t^ NOA Mr M: X.%a. ) — Mgt = P45 NOA 1Vli Method 2 "SimpWied T le Calculatio Table Below" Regabvd Moaaeat of Resistanee (W From Table Below NOA IMS Idr Required Moment Re tatan hMatshop� Ir 2W 3m 39.7 M2 ;FT.4 4o' —40r— WU 3035 39A *'Mast be used in conjuncton with aof moment based the systems endorsed by the Braward County Board of Rules and Ap For Uplift based No systems use Metbod & Compared the values for F' with the values for F.. If the F' values are greater than or equal to the F. values, for each awea•of tate reef, then the lite attachment mathod is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127' ."". (Pi:—zl:--____: Fri:_ �OA.1t'.__.. ••• •• (Ps:—zi:_-,z w:e— 1—Wi�zeOs9:= Frg_ NM FL_ •••• i F.y .____, Nene • • ' Where to Obtain Information . Meese, Descri on S 1 Where to Bud • • • • 000 •• • ' t7sPi,eseaa ar a< 1277aW Iw m • 7 • McaaReaRklift Job lift •. • • RoDfIllave g Jeb she O • • • Mameatdseto NOA • • • • Reguhad Moment Reaidoce bif • Imo Rs00NOARwWmd• • . • e Calculated Avera N JUO Db2mvlons I=kngb NOA w�wtdth IffIlWaussaudbomandftloam of SECTION 1524 HIGH VELOCITY HURRICANE ZONES- REQUIRM OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the rewired roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained 1. Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing-wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. ® 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions -should be corrected. • • • • 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so thellhe roof it hot : • • overloaded from a build up of water. Perimeter/edge walls or other roof extensions may%1N this disc**g*e if , • • • • . overflow scupperswall outlets are not provided. It maybe necessary to install overflow • • • • ' •' • • ( ) pr y ary mappers in oxo edance• with the requirements o£ Chapter 15 and 16 herein and the Florida Building Code, Plubnb b e. 90:0610 ...... ... ..... 7. Ventilation: Most roof structures should have some ability to vent natural ai�Q8l4Qrroug;U e• • • • • •; • interior of the structural assembly (the building itself). The existing amount of attic ventvatitmphall not be '. reduced. Exception: Attic spaces, designed by a Florida-licensed engineer or registered-architEct to $ksr &ge • • • • the attic venting, venting shall not be required .•. • • • • • • Ownees/Agent's Signature: Date: / ;EE • • Contractor's Signature:Permit Number: Property Address: r lo I kve TdUA1366 Roofing Systems TGFU.R1306 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems BUILDING MATERIALS CORP OF AMERICA, DBA GAF 1361 ALPS RD WAYNE, N] 07470 USA 2/10/ 14 10:49 AM R1306 "Ruberoid@ 20" or "Ruberoid@ 20 HT" or "Ruberoid@ Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2-1n. thick (minimum) gypsum board or 1/4 -in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardTM Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system Is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardm Roofboard" are to offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, It must be placed below the overlayment board. Multiple plies of "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "Tri -Ply@ Ply 6" may be adhered to Georgia-Pacific Gypsum LLC "DensDeck @ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardT Roofboard" in hot roofing asphalt. "EnergyGuard7m Ultra" is an acceptable alternate to "EnergyGuardT RF" in any applicable Classification. "GAF Stratavent@ EllminatorT00 Venting Base Sheet (Nallable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. "GAFGLAS@ Perlite Insulation" may be utilized as a cover board over "EnergyGuardTm RF" insulation in any of the following systems. Unless otherwise Indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the following Classifications include "EnergyGuardTM EPS Insulation". Unless otherwise Indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's Installation Instructions (excluding LRF Adhesive O) in any applicable Non -Combustible Roof Deck Classifications. References to glass fiber insulation Include "EnergyGuard Fiberglass Insulation". "EnergyGuardTM Tapered" is an acceptable alternate to "EnergyGuardTM" in any applicable Classification. • • • • ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT • • • • • • • • • • • • • • Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or "Tri -Pty@ #75 Base Sheet", or "GAFGLIke$ "o ULTIMA") II;•a suitaB$•"• alternate for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4", or "GAFGLAS@ Ply I j 4the Class A, Boor C roof :• 6 • systems indicated below. • • •000.6 0 000• The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavenf*fflminator*l Venting Base • • Sheet (Perforated)" or "GAF Stratavent@ EllminatorT Venting Base Sheet (Nailable)." Perforated base sheets to be *wse laid of hilly $dhered' • • • • with hot roofing asphalt and nailable base sheets are to be mechanically attached granule side down. • 000000 •• • 006004 As an option Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet' or "Tri -Ply@ #75 Base Sheer&G.GjFGLAS@ #$Q ULTIMA" • or "GAF Stratavent@ EliminatorTM Venting Base Sheet (Nailable)" may be substituted for Type G1 asphalt glass liber ply sheet 1"' 3,Wj. S@ Ply • • • • 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6") as the nailed base ply in the following systems. 6 •• • Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. • • • ; • • • • Unless otherwise Indicated, all Insulations may be hot mopped or mechanically fastened. "GAFGLAS@ Flashing" or "Ruberoid@" may be used for Flashing in any of the Class A, B or C systems listed below. When "periite" is referenced, this Includes "GAFTEMP PERMALITE@" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. http://database.ul.com/cgi-bin/XYV/template/USOCT/1FRAME/showpa...d=1073741824&version=verslonless&parent Id=1073993597&sequence=i Page 1 of 54 i 6V..111386 - Roofing Systems 2/10/14 10:49 AM Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of Th -in. minimum thick gypsum board Is an acceptable alternate for minimum Insulation over C-15/32 thick roof decks. The use of polystyrene Insulation board between minimum 3A -in. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polylsocyanurate board in the following Class A, B or C systems. "EnergyGuardT" RA" or "Tapered EnergyGuardT" RA" or "EnergyGuardT" Composite RA" may be substituted for any Atlas Roofing Corp. polylsocyanurate Insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS@ #80 Premium Base Sheet" may be used in any of the following systems. "GAFGLAS@ Flex Ply 6" and "Tri -Ply® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLAS@ Ply 6". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite Insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "TOPCOAT® Fires MB" at 2�h to 3-gal/100-f:2. "Ruberotd@ Dual Smooth" may be used as an alternate to "Ruberoid@ Mop Smooth" or "Ruberoid@ 20" or "Ruberold@ 20 HT" "Ruberoid@ Mop Smooth 1.5" may be used as an alternate to "Ruberoid@ Mop Smooth" Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid@ Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid@ Mop" SBS products in any applicable Classification. Class A 1. Deck: C-15/32 Incline: 3 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or Polylsocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanu rate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type Gi or "GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS@ Ply 6" hot mopped. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocya nu rate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type G1 or "GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS@ Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet " or "GAFGLAS@ EnergyCap— BUR Mineral Surfaced Cap Sheet." 3. Deck: NC Incline: 2 Insulation (Optional):— Oneor more layers perlite, wood fiber, glass fiber, Polyisocyanurate, urethane, perlite/poly�so�ya+laurate composite, fiber/Polyisocyanurate wood composite, phenolic, 2 -In. maxim:om. • • • • • Ply Sheet; —Two or more P Type GI GAFGLAS@ Ply "Tri • • 000806 • 4", -Ply@ Ply 4" or GAFGLASO Ply 60• • • : • • • • Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap "Tri • Sheet" or -Ply@ Mineral Surface�l6Crapeet" or "Gi(6tAS@ EnergyCapT" BUR Mineral Surfaced Cap Sheet." • �. •; • • •09.00 • 4. eck: C-15/32 Incline: 1 :0660: • •06 60 • 0000 • • 0 •906.6 Slip Sheet (Optional): — Red rosin paper, nailed to deck. 0000 6 0 • •0: 6 9 • Insulation (Optional): — Any thickness perlite or wood fiber or lass fiber or I i • • 6 6 • • . • • 6 6 6 9 6 9 po y socyanurate mecha� �cej1ly� fastenef1p; A$tfered w;;::: OMG Inc. "OlyBond Fastening System" or any UL Classified Insulation adhesive. Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" (may be:0114ry • Ply Sheet: — One or more plies Type Gl "GAFGLAS@ Ply "Tri . • 6 4" or -Ply® Ply 4 or GAFGLAS@ Ply 6". e • • • Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap "Tri 9 0 00 • • Sheet" or -Ply® Mineral Surfaced Cap $heet" o4d'G•AMtAS@ EnergyCapT" BUR Mineral Surfaced Cap Sheet." 6 • 000 Surfacing (Optional): — ""TOPCOAT@ EnergyCoteT" Elastomeric Coating" applied at a rate of 2-gal/102. 0 :060 331ft 000800 6 6 S. Deck: NC Incline: 3 Base Sheet* — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet". Ply Sheet: — One or more plies Type G3 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or'Tri-Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCapT" BUR Mineral Surfaced Cap Sheet." http://database.ul.com/cgi-bin/XYV/template/USEXT/1FRAME/showpa... d=1073741824&version=versionless&parent_id=1073993597&sequence=1 Page 2 of 54 MIAMI-DADE COUNTY MIAMNDADE ` PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy -GAF_ 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material falls to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF ConventionaFBuilt-Up Roof System for I Wooid(Deeks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or cb Mtge in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any pfoduct,..... for sales, advertising or any other purposes shall automatically terminate this NOA. Failure fo ad4ly with any section of this NOA shall be cause for termination and removal of NOA. 6 • • 6 .. . • 9999.. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, F14fiWgnd foJ4yvp6.by the • expiration date may be displayed in advertising literature. If any portion of the NOA is displayetC then it'shall be done in its entirety. .. .. .. . 9999.. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufact: rei:og its di%tribu4ors and,,.,:, shall be available for inspection at the job site at the request of the Building Official. :09666 6 0 . •9066. .. 9999 This NOA revises and renews NOA No. 07-1219.09 consists of pages 1 through 17. 000 • The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-0424.09 MIAMbDADE COUNTY -- ... , Ea:piration Date: 11/04/14 - Approval Date: 10/31/13 Page 1 of 17 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: BUR Material: Fiberglass Deck Type: Wood Maximum Design Pressure: -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions GAFGLAS®#75 Base 39.37" (1 meter) Sheet Wide GAFGLAS® #80 Ultima'" 39.37" (1 meter) Base Sheet Wide GAFGLAS® F1exPly'*m 6 39.37" (1 meter) Wide GAFGLAS® Ply 4 39.37" (1 meter) Wide TABLE 1 Test Product Specification Description ASTM D 4601 Type H asphalt impregnated and coated glass mat base sheet. ASTM D 4601 Type II asphalt impregnated and coated, fiberglass base sheet. ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. ASTM D 2178 Type IV asphalt impregnated glass felt with asphalt coating. GAFGLAS® Mineral 39.3T'(1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet surfaced Surfaced Cap Sheet Wide with mineral granules. GAFGLAS® EnergyCap'*m 39.37" (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet surfaced BUR Mineral Surface wide with mineral granules with factory applied Cap Sheet EnergyCote"' GAFGLAS® Strataven? 39.37' (1 meter) ASTM D 4897 Fiberglass base sheet coated on both sides with EliminatormPerforatedWide asphalt. Surfaced on the bottom side with mineral Venting Base Sheet granules embedded in asphaltic coating with factory perforations. GAFGLAS® Stratavene 39.3T'(1 meter) ASTM D 4897 0000 A nailable, fiberglass bast shp8timpreg!Me*d and EliminatormNailable Wide coated on both sides with & haft. SurfaNd obi the '. Venting Base Sheet bottom side with mineral •mules embeddeain **see: 0000. asphaltic coating. • • • • • • Ruberoid® SBS Heat- 39.37" (1 meter) ASTM D 6164 0000 Non -Woven Polyester mat'cbMed witYpolymer- 66; 660 Weld's Smooth Wide modified asphalt and smdoU surfaced.. • • . • . • • • • • .. .. 0000.. Ruberoid® SBS Heat- 39.37" (1 meter) ASTM D 6164 Non -Woven Polyester m�tt�ted with polymer- polymer- • 0 Weld"m 25 Wide modified asphalt and smdbth suffaced....;. 660600 Ruberoid® 20 39.37" (1 meter) ASTM D 6163 . SBS modified asphalt base shee; reinforceaarkh a • • • Wide glass fiber mat. 000 • NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 2 of 17 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Ruberoid® Mop Smooth 39.37' (1 meter) ASTM D 6164 Non -woven polyester mat coated with polymer - wide modified asphalt and smooth surfaced. FireOe Fire Barrier 5, 55 gallons Proprietary Low VOC, water based fire barrier coating. Coating VersaShieie Fire 350 sq ft. roll ASTM D 226 Non -Asphaltic Fiberglass -Based Underlayment. Resistant Roof Deck Protection Topcoat® Surface Seal 5 gallons ASTM D 6083 Solvent based sprayable thermoplastic rubber SB sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuardTM Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"' RA Polyiso Insulation Polyisocyanurate foam insulation EnergyGuarC RN Polyiso Insulation Polyisocyanurate foam insulation EnergyGuarC Perlite Roof Insulation Perlite insulation board. EnergyGuardTM Perlite Recover Board Perlite recover board EnergyGuardm RA Composite Polyiso Polyisocyanurate foam insulation with high Insulation density fiberboard or Permalite perlite insulation SecurocV Gypsum -Fiber Roof Board Gypsum roof board StructodeV High Density Fiber Board High density fiber board GAF GAF GAF .� GAF • USG Corpgvn ..00.0 Biva kiJge Fibw Inc. • , oa;d, 060.64 000666 0000.. 0000.. 0000 . 0000. .. .. 66 6 666666 0000.. . . 0 . . . . 666666 0000.. 0 . :Goes: 0000.. 66 6 6666 6 6 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 3 of 17 APPROVED FASTENERS: Does . . 0000 0000.. TABLE 3 soa Fastener Product Product Manufacturer Number 000000 • . • Name Description Dimensions (With Current NOA) 1. Drill -Tec"' #12 Fastener Insulation fastener for steel, various GAF •0009••• • DOD•• wood & concrete decks. •• •• •• • •0999• 2. Drill -Tec"' #14 Fastener Insulation fastener for steel, various GAF wood & concrete decks. 3. Drill-Tec'*m XHD Fastener Carbon steel extra heavy duty Various GAF 00*0 fastener used in steel decks. MMaADE 4. Drill -Tec"' ASAP 3S Drill-TecTM #12 Fastener Various GAF with Drill-TecTM 3" Standard Steel Plate 5. Drill -Tec' 3" Steel Plate Round galvalume stress plate 3" round GAF used with Drill -Tec"' fasteners. 6. Drill -Teem 3" Standard Steel Round galvalume plated steel 3" round GAF Plate stress plate with reinforced ribs for use with Drill-Tec"m fasteners. 7. Drill -Tec"' AccuTrac® Flat AZ -SS aluminized steel plate 3" square GAF Plate for use with Drill -Tec"' #12 Fastener, Drill -Tec"' #14 Fastener and Drill -Tec"' #15 Fastener. 8. Drill -Tec"' AccuTraco Galvalume Steel plate for use 3" square GAF Recessed Plate with Drill -Tec"' fasteners. Approval Date: 10/31/13 Page 4 of 17 Does . . 0000 0000.. . . soa •o•e•e .o 0990:6 000000 • . • 0000•• 0000 a • • 0000•• •0009••• • DOD•• • • • • . •• •• •• • •0999• • o•o•o• • • •• a •••• • • 00*0 NOA No.: 13-0424.09 MMaADE ;ui Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 4 of 17 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Factory Mutual Research Corp. J.I.2B8A4.AM 4470 Ll. 3B9Q 1.AM 4470 J.I.ODOA8.AM 4470 J.I.ODIA8.AM 4470 - TAS 114 J.I.OY9Q5.AM 4470 - TAS 114 •6i••• 3029832 4470 - TAS 114 PRI Asphalt Technologies, Inc. GAF -084-02-01 ASTM D 6083 6666•• GAF -314-02-01 ASTM D 2178 GAF -315-02-01 ASTM D 2178 6666 GAF-276-02-01Rev ASTM D 6083 • • GAF -276-02-02 ASTM D 226 GAF -270-02-02 ASTM D 226 IRT of S. Fl. 02-005 TAS 114 ••6••9 02-014 TAS 114 Trinity I ERD G6850.08.07-1 ASTM D 3909 •• 6• G34140.04.11-4 ASTM D 6401 G30250.02.10 -3-R1 ASTM D 3909 6••6••• G34140.04.11-5 ASTM D 4897 G34140.04.11 -5-R1 ASTM D 4897 • • G34140.04.11-2 ASTM D 6163 Date 07/02/97 01/08/98 07/09/99 07/29/94 04/01/98 05/11/07 05/09/06 08/23/11 08/23/11 12/16/10 11/15/10 11/15/10 01/18/02 03/22/02 08/13/07 04/25/11 11/26/12 04/25/11 10/18/13 04/25/11 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 5 of 17 •9•• .... 6096•6 •6i••• •• 00•60• • 6666•• • • • •6•••• 6666 • • • • • • •9•••• • ••6••9 f• • 6666• •• 6• •• • 6666•• • 6••6••• • • • • • ••••9• 6666•• � • • 6666•• ee • •••• NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 5 of 17 APPROVED ASSEMBLIES Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftp EnergyGuardTM Polyiso Insulation, EnergyGuardTM RA Polyiso Insulation, EnergyGuardTM RA Composite Polyiso Insulation Minimum 1" thick N/A N/A EnergyGuardTM Perlite Recover Board Minimum %2" thick EnergyGuardTM Perlite Roof Insulation Minimum %" thick N/A N/A N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ftp. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene EliminatorTM Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieie Fire -Resistant Roof Deck Protection or (optional) SecurocV Gypsum Fiber Roof Board. Anchor sheet: GAFGLAS® #80 UltimaTM Base Sheet, GAFGLAS® Stratavene Eliminatofm Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat-WeldTM Smooth or Ruberoid® Heat-WeldTM 25 base sheet mechanically fastened as described below; 0000 Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Blse pget or;fY84bove .... • anchor sheets attached to deck with approved annular ring shank nails and tin c1P9 at 3 '. fastener spacing of 9" o.c. at the lap staggered and in two rows 12"'o.60*1 in the field. 0 090006 (Maximum Design Pressure —45 psf, See General Limitation #7; • • • • GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6, GAFGLAS® #75 BaslsSt et or aiiy of above anchor sheets attached to deck with Drill-Tedrm #12 Fastener, Drift-*te"d4* #14 aa'sener ando .. . ...... Drill-TecTM 3" Steel Plate, Drill-TecTM AccuTrace Flat Plate or DM T. cTM Accu.Trac® • Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. 'the etljer rowis are jequally. .,,;, spaced approximately 12" o.c. in the field of the sheet. . . :09000 . . (Maximum Design Pressure ,4S psf, See General Limitation #7)0..' i 0000 i""i NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 6 of 17 GAFGLAS® F1exP1yTM 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid®20, Ruberoid® Mop Smooth, base sheet attached to deck with approved 1'/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill- TecTM #12 Fastener, Drill-TecT #14 Fastener and Drill-TecTM 3" Steel Plate, Drill-TecTM AccuTrace Flat Plate or Drill-TecTM AccuTraco Recessed Plate 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill- TecTM #12 Fastener or Drill-Tedm #14 Fastener and 3" Drill-TecTM 3" Steel Plate, Drill- TecTM AccuTrace Flat Plate or Drill-TecTM AccuTrace Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Base Sheet: Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® 480 UltimaTM Base Sheet, GAFGLAS® Stratavene Eliminatofm Perforated Venting Base Sheet, Ruberoid® Mop Smooth, Ruberoie 20, Ruberoid® SBS Heat-WeldTM Smooth or Ruberoid® SBS Heat- WeldTM 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation #4). Ply Sheet: One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet or GAFGL'AS8.#80 Ultima Base Sheet adhered in a full mopping of approved asphalt appliedwithin the *gVT range and at a rate of 20-40 lbs./sq. .. • 0 0080•• 0000 0000 0000.. 0000•• • 0000.. •• o 0000•• • 0000 0000.. 0000.• .0000. .•66. 0000. 6••••• • 0 • •••••• •6009• • • NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 7 of 17 Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. 1. Gravel or slag applied at 4001bs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. Maximum Design Pressure: See Fastening above. NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 8 of 17 Dose D . . . *::Go* .069..0 . ...... .. ...... .00000 . . e ... .... 900.. • . .... . ......... ...... .. . ....6.• . . . . ..0..9 ..0000 . 0 000 :0090: 00 6 6000 0 . 0000 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 8 of 17 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type B: Optional base sheet laid dry; base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer Insulation Fasteners Fastener (Table 3) Density/ftz EnergyGuardTM Polyiso Insulation, EnergyGuardTM RA Polyiso Insulation Minimum 1.3" thick 1, 2, 3 or 4 1:3 ft2 EnergyGuardTM RN Polyiso Insulation Minimum 1.4" thick 1, 2, 3 or 4 1:3 ft2 EnergyGuardTM RA Composite Polyiso Insulation Minimum 1.5 thick 3 1:3 ft2 EnergyGuardTM Perlite Roof Insulation Minimum W thick 1, 2, 7 or 8 1:2 ft2 StructodeV High Density Fiberboard Minimum 1" thick 1, 2, 7 or 8 1:4 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). GAF requires either a ply of GAFGLAS® Stratavene EliminatorTM Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Insulation for Top Layer (Table 2) Insulation Fasteners Fastener (Table 3) Density/ftp Any of the insulations listed for Base Layer, above. N/A N/A 0000 StructodeV High Density Fiberboard, EnergyGuardTM Perlite Recover Board • • • • • • • • • • • • . • Minimum V2" thick N/A609:00 •• %T/40 0 0 0. Note: Optional top layer of insulation shall be adhered with approved asphalt within the Ulff•range and at a o 0.. • rate of 20-401bs./100 W. Please refer to Roofing Application Standard RAS 117 for insvWd'q attacblq� 000 • Composite insulation boards used as a top layer shall be installed with the polyisocyanurafe face do*n. 80:949 • 0000.. .. . 00006 Fire Barrier: FireOutTM Fire Barrier Coating, VersaShiele Fire Resistant Roof De&k "ection of • • • • (optional) SecurockTM Gypsum Fiber Roof Board. • • • • • • • 0000.. 0000.. 0 00 • . 00.. 00 . 0000 0 0 00 0 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 9 of 17 Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima Base Sheet, GAFGLAS® Ply 4, GAFGLAS® FlexP1yrm 6, GAFGLAS® Stratavene Eliminator - Perforated Venting Base Sheet laid dry, Ruberoie Mop Smooth or Ruberoid®20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4). Ply Sheet: Two or more plies of GAFGLAS® Ply 4, GAFGLAS® FlexPly'm 6 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See specification number for appropriate number of plies). Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See GAF application instructions for approved method of installation). Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. Maximum Design Pressure: -45 psf, (See General Limitation #7) NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 10 of 17 6666 . . 6006 6666.. 666600 .. 6666.0 600906 0 0 0 6666996 000000 6666.. •660 ... 90966 6666.. 6666. 0 . . 9 .. .. .. . 6666.. 666696 • 6666.. 90 9 6060 0090 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 10 of 17 Deck Type 1I: Wood, Insulated Deck Description: 19/32 1 or greater plywood or wood plank System Type C: One or more layers of insulation simultaneously attached; Base layer optional. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM RN Polyiso Insulation, EnergyGuardTM Polyiso Insulation, EnergyGuardTM RA Polyiso Insulation Minimum 1.3" thick N/A N/A EnergyGuardTM Polyiso Insulation Min. 1.4" thick N/A N/A EnergyGuardTM RA Composite Polyiso Insulation Minimum 1.5" thick N/A N/A EnergyGuardTM Perlite Recover Board Minimum %" thick N/A N/A StructodeV High Density Fiber Board Minimum 1" thick N/A NIA Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavene EliminatorTM Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Insulation for Top Layer Insulation Fasteners (Table 3) EnergyGuardTM Polyiso Insulation, EnergyGuardTM RA Polyiso Insulation Minimum 1.3" thick 1, 2, 3 or 4; . •, EnergyGuardTM RN Polyiso Insulation .:::096 669•. Minimum 1.4" thick 1, 2 or 3 goo*** •9.6 EnergyGuardTM RA Composite Polyiso Insulation ... • • Minimum 1.5 thick 3 • • • • • 6 EnergyGuardTM Perlite Roof Insulation ::.:Soo Minimum W thick 1, 2, 7 or 8; • StructodeV High Density Fiber Board ! .0. Minimum 1" thick 1, 2,7 or 8 • Fastener Density/fe 9.6. • •s• . 04,• 1?;;2 • 0 • •0000. 600000 • •66.. 04.3ft2 • •669• • i • 69 • 006996 s • 1:2 ft2 ....:. 9.90•• • e 9 ••91•• ')4 ft2 6 • NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 11 of 17 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavene Eliminatoem Perforated laid dry or a layer of EnergyGuardTM Perlite Roof Insulation or wood fiber overlay board on all isocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShiele Fire Resistant Roof Deck Protection or (optional) SecurockTM Gypsum Fiber Roof Board. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima'' Base Sheet, GAFGLAS® Ply 4, GAFGLAS F1exP1y7m 6, GAFGLAS® Stratavene Eliminatofm Perforated Venting Base Sheet laid dry, Ruberoid® Mop Smooth or Ruberoid® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; see General Limitation #4. Ply Sheet: Two or more plies of GAFGLAS® Ply 4, GAFGLAS® F1exPly1m 6 ply sheet or GAFGLAS® #80 Ultima'' Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at lto 1.5 gal./sq. Maximum Design Pressure: 45 psf, (See General Limitation #7) NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 12 of 17 0000 ..••.• •• 0000•• 0000•. . • • .•.• . • .0000• 0000•• •.•• • 00000 0000• • • •• •• •• • •••••• 0000•• 0 • • • • • 0000•• 0000•• •• • 0000 • • 0• • NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 12 of 17 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type D: Insulation and Base sheet simultaneously All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer loosely laid with firmly butted joints. Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM Polyiso Insulation, EnergyGuardTM RA Polyiso Insulation Minimum 1.3" thick N/A N/A Structodek® High Density Fiber Board Minimum 1" thick N/A N/A Fire Barrier: FireOufm Fire Barrier Coating, VersaShiele Fire Resistant Roof Deck Protection or (optional) SecurockTM Gypsum Fiber Roof Board. Base Sheet: Install one ply of GAFGLAS4#75 Base Sheet, GAFGLAS® #80 Ultima.TM Base Sheet, GAFGLAS® Stratavene EliminatorTM Nailable Venting Base Sheet or Ruberoid® 20 base sheet applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Options: Drill-TecTM #12 Fastener or Drill-Te6m #14 Fastener and Drill-TecTM 3" Steel Plate, Drill- TecTM AccuTrac® Flat Plate or Drill-TecTM AccuTraco Recessed Plate is installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) Drill-TecTM #12 Fastener or Drill-TecTM #14 Fastener and Drill-TecT 3" Steel Plate, Drill- TecTM AccuTrace Flat Plate or Drill-TecT AccuTrace Recessed Plate is installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid®20, Ruberoid® Mop Smooth, base sheet attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of fie• • • membrane. • • • • ' • "" (Maximum Design Pressure —60 psf, See General Limitation #7) •' • ...... .. ...... Drill-TecTM #12 Fastener and Drill-TecT #14 Fastener and Drill -Tee's 3 Steel Plate, Drill- ; . • .. ; TecTM AccuTraca Flat Plate or Drill-TecTM AccuTrace Recessed Plata hig rowsoIXA.G. ' One row is in the 2" side lap. The other rows are equally spaced appfftftiately 9" o.c. in the • • • • field of the sheet. 94:09: (Maximum Design Pressure —60 psf, See General Limitation #7) • • • • • • • • • Ply Sheet: One or more plies GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6 or QAFGL•AS® #"Ultima ' • • • Base Sheet adhered in a full mopping of approved asphalt applied v4 Shia Ike EVt rano: and • • • • at a rate of 20-40 lbs./sq. MIAMI•DADE COUNTY NOA No.: 13-0424.09 APPROVED Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 13 of 17 Y ( , • Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions 1. Gravel or slag applied at 4001bs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. Maximum Design Pressure: See Fastening Above 0000.. 0000.. 0000 0000.. 0000.. 0000 .000.0 0000.. • • NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 14 of 17 0000.. 0000.. 0000.. 0000. 0000. 0000.. .0000. .0000. 0 Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOufm Fire Barrier Coating, VersaShieie Fire Resistant Roof Deck Protection or (optional) SecurockTM Gypsum Fiber Roof Board. Base sheet: GAFGLAS® #80 UltimOT Base Sheet, Stratavene Eliminatorrm Nailable Venting Base Sheet, Ruberoie 20, Ruberoid® SBS Heat-Weldrm Smooth or Ruberoid® SBS Heat- We1dTM 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® F1exP1yTM 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® F1exP1yTM 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-Tecrm #12 Fastener or Drill-TecTM 414 and Drill- TecTM 3" Steel Plate, Drill-TecTM AccuTrace Flat Plate or Drill-TecT AccuTrace Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS® Flex-P1yTM 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck -with approved annular ring shank nails and tin caps -at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9ff-o.c.' in the field.' (Maximum Design Pressure -52.5 psf, See General Limitation #7), GAFGLAS® 480 UltimaTM Base Sheet, Ruberoid®20, Ruberoid® Mop Smooth, base sheet attached to deck with approved 1 %4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure -60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-Tecrm #12 Fastener or Drill-TecTM #14 Fastener and Drill -Tec rm 3" Steel Plate Drill iKe em *goo:* AccuTrace Flat Plate or Drill-Tecrm AccuTrac® Recessed Plate 12 ; Q In 4 r%v% Ove . row is in the 2" side lap. The other rows are equally spaced apprg76igW%Iy 9" o.c. ince • • • • • field of the sheet. 660:66 • 6666.. (Maximum Design Pressure -60 psf, See General Limitation #7) .... • . . 6666.. 6666. Any of above Base sheets attached to deck approved annular ring ""yails and 3". ..: • • inverted Drill-TecTM insulation plates at a fastener spacing of 9" o" U Oe 4" lap staggered • • • • • • in two rows 9" in the field.6666.. • (Maximum Design Pressure -60 psf, See General Limitation #7): 0 • 0 • ..... .0000• . 6666.. 6666 NjOA N 13=4424.09 _ Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 15 of 17 i 1 , GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM #12 Fastener or Drill-TecTM #14 Fastener and Drill-TecTM 3" Steel Plate, Drill-Tecrm AccuTrace Flat Plate or Drill-TecTM AccuTrace Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) My, Sheet: One or more plies of,GAFGLAS® Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap -Sheet: (Optional), One ply of GAFGLAS® Mineral" Surfaced Cap Sheet or GAFGLAS® EnergyCap rm BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq. Maximum Design Pressure: See Fastening Above •6•••• 6066•. 0000• 0000. 6666•• • • •• • 6666 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 16 of 17 6666•• 0600 • 0000 0000.• •6 0000.. 0000 • 0.06.. 0.66• 6666•• • 6666•• •6•••• 6066•. 0000• 0000. 6666•• • • •• • 6666 NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 16 of 17 6666•• WOOD DECK SYSTEM LEVIITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex P1yTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/V Dens DeckTM Roof Board or 1/2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referral, within this NOA, General Limitation #9 will not be applicable.) 0 0 0 0000 0 608090 8. All attachment and sizing of perimeter nallers, metal profile, and/or flashing termination •designs shalltMfo*n to 0. Roofing Application Standard RAS 111 and applicable wind load requirements. • • 0:64 • • fee*** 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure Zdfiffo.e. field, ' LOGO: perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for•eMaced f1stesg at • • • • • enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specific�ly 09:069 referred within this NOA, General Limitation #7 will not be applicable.) • • • • • 10. All products listed herein shall have a quality assurance audit in accordance with the Flo • • • • • • • • • • • • p q ty nc�,$�lding Code and • Rule 9N-3 of the Florida Administrative Code. ; • ; . • *see: END OF THIS ACCEPTANCE ...... •• • 0000 • • 00:• 0 NOA No.: 13-0424.09 IAPPRMIAMbDAD; COUNTY Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 17 of 17 p Z� a ✓ „ar "a°�''� �' � 3 `mow -0 �`"'.', �`'. _ F . n <a; d ar+,