MC-14-1230 (2)Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-214059 Permit Number: MC -6-14-1230 Scheduled Inspection Date: August 11, 2014 Inspector: Perez, JanPierre Owner: PECK, STEPHEN Job Address: 173 NE 107 Street Miami Shores, FL Project: <NONE> Contractor: RESIDENTIAL AIR INC Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: New A/C System Phone Number (305)801-4427 Parcel Number 1121360070310 rsunaing uepartment comments INSTALLATION OF 3 1/2 TON AC SYSTEM Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction ❑ Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. August 08, 2014 For Inspections please call: (305)762-4949 Page 4 of 27 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 (C> Permit Type: MECHANICAL LJUN 12 2.14 BY __. Permit No. WC1L 1 230 Master Permit No. g,nat, &L',�,P/ Owner's Name (Fee Simple Titleholder) �ze-&ew Phone # 30 -5 --rel- yyd2% Owner's Address 17-3 fi f D -7 Cit1f,"I x, State 7.f Zip 33/(o/ Tenant/Lessee Name Phone # Email Job Address (where the Work is being done)/®� �= City Miami Shores Village County Miami -Dade Zip 33 / io / FOLIO / PARCEL # Is Building Historically. Designated YES NO Flood Zone Contractor's Company N Contractor's Address 16 City Z1` 0L Qualifier Name Phone #_,3V,4-- &s— a & .0 S��a State Phone # State Certificate or Registration No. �%6iLrp �� Certificate of Competency Contact E-mail Architect/Engineer's Name (if applicable) At Phone ,A i. / Value of Work For this Permit ifs" Square / Linear Footage Of Work: _ Type of.Work: ❑Addition ❑Alteration mew ❑ Repair/Replace Describe Work: S9 ❑ Demolition eZill)f�.esA Submittal Fee ermit Fee $ l t CCF $ CO/CC $ Notary $ Training/Education Fee $ Scanning $ Radon $ DPBR Double Fee $ Violation date: Structural Review. $ Technology Fee $ Bond $ Total Fee Now Due $ See Reverse side -� ]Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State t Zip Zip. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and 'that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY -RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the 'inspection will not be approved and a reinspection fee will be charged. Signature Signature " y Q--� - -' e�`� �� •® `�®`�` 110111 `� A for The foregoing ins p4�t wa"to before me this !/ The foregoing i ®® ged before me this-/ 1 day of I WL4 P day of " bc's� .. who is personally ea6r wh roduced who is pe ona '*1k, t�Qlie s produced i.i nd who. did take an oath. i Yc to a# who did take an oath. NOTARY P f -i/1i1�111111 ' •• WAF NOTARY Sign: �' Sign: _ Print: L-1 p—A 4dZv1& i Print: C -Z -0A i itell My Commission Expires.: My Commission Expires: APPROVED BY P Ins E miner Zoning Engineer (Revised 07/10/07)(Revised 06/10/2009) Clerk checked Flom: Residential Air Inc Subject° 173 NE 107 Sheet 00e: June 6, 2014 at 9:55 PM RESIDENTIAL AIR INC. 1662 NE 205 TERRACE MIAMI, FLORIDA 3:3179 305-652-6040/964-764-0489 STATE LICENSED AND INSURED CAC036484 Dr. S. Peck NE 107 Stmt Miami Shores, Florida 33161 Residential Air will furnish and install the following: Rheem 3 1/2 ton Super High -Efficiency 16 seer split cooling system. Condenser model 14AJM42 will be Installed and secured on a new Dade County approve slab. Air handier model RHLL3821 will be installed on a new stand. Instaailation includes the following: Fabricate and install new ductwork with white grills. Balanced returns for bedroom. Refrigeration lines. Digital thermostat. Float switch. Heater. Provide all labor and materials for a complete and professional installation. One year warranty labor and 10 years manufactures warranty on parts. Price does not Include permit fee. Payment terms are 50°to deposit and balance upon installation. All electrical work by others. ;i t l l! 11 iMU-7A I tt tlt Respectfully, c . Richard Residential Air Inc. Approved by ' , FPL Acct #RV91 d f�7 10330 Thank you, Ellen General Manager Residential 1662 NE 205 Terrace Miami, Florida 33179 305-652-60 40 / 954-764-0489 State Licensed and Insured This combination qualifies for a Federal Energy • Efficiency Tax Credit when placed In service between Feb 17, 2009 and Dec 31, 2010. t;ertfflc0&Ae0-ftfti AHRI Certified Reference Number: 3806012 Date: 10/27/2010 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 14AJM42 Indoor Unit Model Number: RHLL-HM3821+RCSL-H*3821 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 14AJM SERIES Manufacturer responsible for the rating of this system combination Is RHEEM MANUFACTURING COMPANY Rated as follows. In accordance with AHRI Standard 210/240-2006 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, Independent, third party testing: Cooling Capacity (Btuh): 40000 EER Rating (Cooling): -13.00 0000 SEER Rating (Cooling): 16.00 • . ' 0000 000 .. ••r• 060.80 •• . ••• 00700 0000.. V ... 0000.. ' 0000.. . •• • 0000 ' • 0000 , I * Ratings followed by an asterisk (7 Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which Indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) Rated an this Certtfiaats. AHRI expressly disclaims all debility for damages of any kind arising out of the use or performance of the product(sh or the unauftntzed alteration of data dated on this Certi irate. Certified ratings are valid only for models and configurations fisted M the directory at www ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shad only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or M part, be reproduced; copied; disseminated, entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except forthe user's Individual, personal and confidential reference. CERTIFICATE VERIFICATION The inforit. for the model gifted on this certificate can be verified at www ahridirectory org, Air -Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on No SEand Refrigeration Institute which the certificate was Issued, which Is listed above, and the Certificate No, which Is listed below. ©2010 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129326694211360750 Desi n5tar Load Calculation Results an- intended for use with Rheem heating and cooling systems Ceiling U -value. R -value ' 0.053 19 0•�• Window U -value 0000 0000. . SHR .75 58 Duct loss % 10` Duct gain % 10 .. 0000 Heating infiltration (ACH) _.:........ :0000. _..:. _.. � 0000 _: _ _. �.w:... _ _0000.._ . _._..: _ _ ....-:.....:.......... Summer ventilation 0 Number of residents 2 •••••• • . 0000.. 0000 Ceiling height 9 0000 00000. 0000.. .. .. 60..0 _:_0000..._ 000_,0..., . Wall U -value R -value 0.09111 .. .. .. 0000.. - •0,•„ • 0. 6' ---- --------- FlaorU-value I R -value 0 0 0 ..... .................. .... _........ 0.2 15 .... ... . 0 . . .6090. 00.000 �: . . ..f 0.0 0000. - - __ .. _ _ __ _ -- _ _ -_ _ _ ......... ... - -.. -- 0000 Ceiling U -value. R -value ' 0.053 19 0•�• Window U -value 0.5 Window SHGF 0.85 Moisture grains 58 Duct loss % 10` Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 Outdoor HeatingCooling Dry bulb (°F) 50 90 Daily range L Relative humidity 50% Moisture difference 58 Indoor Heating Cooling -- Indoor temperature (°F) 70 75 Design temperature difference(OF) 20 15 Area Btuh % of load Wail 2352 13.4 Floor 4000 22.8 Ceiling_ 2056 11.7 Windows 2790 15.9 Infiltration 4763 27.1 System Efficiency Loss 1596 9.1 Tota 1: 17558 Heating Loads _. . System Efficiency Loss Infiltration Ceiling • • • • • • 0000 0000•• --Wall • •••r•• •000 • • • • • • •••0 • •r'•• • 0000• Floor • :••:•: • •• . Windows • • •••s• • 0000 ••• • • • • `.0 • •0000• AED Graph 20000 _ 77 A 10000 _ :000 0 Sam 92ml loam 11arn 12prn 1pm 2pm Spm 4pm Spin 6trrm 7p-n _ -Prn -- Hourly Loads — Average Glass (E) .. 141 sq. ft. Glass (S) 20 sq. ft. ...... ........... . _.... .:.................. 0000..._ .. Glass (N) 20 sq. ft. • • • • •. ...__. -------- �___-_. ._ .. 0_000_......_�.. .., _ 0_0_00 .___.__- ...._:i• • 000* Glass (W) 98 sq. ft. 0000.. .. 0000•. .._..._...-. 00_0:0;:. 0__:000-.. ... ,...:. _;: ... ..._.:. < .. ..._-... • • Summer Outdoor 90°F 0 :000.0 :0004• ,..__ 0000 _ _ 000.0. _.. • .•00. Summer Wet Bulb 77°F 0000•• :0 • • � •4:•• 00 0 66 0640:6 _ , , 00,00 _0000 _._ . 0000__0 Summer Indoor _.. ._::0000 _,..... ._. _...._ _ .... .... :::.. . 75°F . ••0•.• 0 *0 0 ' 0 00000. --------- --- . _--- --- :0000* Summer Design Grains 50% �_:__... 0::000 _:.:_0000 ..� _.. ,. _00.00... _ :.. 0000 _..:_ ._.:_: . - -.. Winter Outdoor 50°F ..... __ ..... _ . _....... ........... . _ 0000_. Winter indoor r _ . _ 70°F' Sensible Cooling 29,736 Btuh Latent `Cool ing 6,864 Btuh Required Cooling Airflow 1,352 CFM Sensible Heating 17,558 Btuh Required Heating Airflow 228 CFM °.+ •caiculabons, are gases: upon approved hvac ,roc£ str-y standards and procedures, and comply wijl all !ocat, _t-ate and fe'ieral rode requirements, All s; oit?%}l.lt d rFstd!- are Estimate_, Product provided by Energy DP_si+3 C'k