Loading...
BPP-12-2265 (3)Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-207205 Permit Number: BPP -11-12-2265 Inspection Date: February 13, 2014 Inspector: Dacquisto, David Owner: SFARA, VERONIQUE Job Address: 1080 NE 105 Street Miami Shores, FL 33138 - Project: <NONE> Permit Type: Pools/Whirlpools/Hot Tubs Inspection Type: Survey Final Work Classification: Addition/Alteration Phone Number (305)799-2006 Parcel Number 1122320280090 Contractor: ALL CONSTRUCTION & DEVELOPERS INC Phone: (786)768-4330 Buildina Department Comments POOL & CONCRETE DECK Infractio Passed comments INSPECTOR COMMENTS False 3/21/13 bond refunded to landstone builders. New contractor pending to pay new bond. / Inspector Comments Passed l Failed Correction Needed 1 Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. For Inspections please call: (305)762-4949 February 13, 2014 Page 1 of 1 Y" AL W. 72ad AVENUE SUITE NAM FL°—'o'erJOHN IBARRA & ASSOC. INC. SIIRVEYA1m '2.� '-' •am LJ Un SU)MYORs DRAWN BY. YCH SHEETAto. f OF 2 1080 N.E. 105th STREET MIAMI SHORES. FL 33138 LEGAL DESCRIPTION: LOT 9. BLOCK 1. OF MIAMI 5HORES ESTATES, ACCORDING TO TtiE PLAT THEREOF A5 RECORDED IN PLAT BOOK 47. AT PAGE 58, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. LOCATION SKETCH HOTTOBGItH "� •.•� Its how- LULU.. •�..,..� F E�TtI gpm �. I 1 Y iStTooNo - 1ti9{ Al It, low U1f11 A a Aja. IRIYIi.r ..wl.Y.-.asY w.ti/WHSV A.C.- WE 47A�IlZWOA FAD..'' ME - ASIC RON SW : lO�F. A.H.a ATA�Q11 H Rlr M.D.C.R.- MUM COMM Ung.- 027mw. A.B.: ALWg31W ROTS? x. H. : lO8>tASgS v.H.- 0lILIlY HABYJQJWl'. A.H. • AAIRATIs. v.F. • OTZLnW FOli. ABPHA�Ll. S.A.F.: Am A FART DIP. W.K.- Nam �. H.C..a : 8LOL7(. KINDm S1ilZOm QHDIA3'ZC VsFamCAL IDITOL Y.F.- VOW 5HA4i, HZDO.- SviTdi . $S S.l.Ba HOT M BT9LH. V. a. TODD NEW. H.10 - Him AM. iiO.a tom. P.R.- mm ROOF. B.C.R.- 8A0i�11D i3DOiTY R>ir 0/8 - Ol1ITTm. Y.1/.• TOIHR TOLVH. H.O.H.- HABIB' OO' O.H.- OA9TRTlBAD td m MVAMDNW xam. W - A S. OVHRmw Omzw LIHYB. CHYl7i6R ITOZ• C.H.- C Hygid/. , O.H.H.- OFFlCZAL 85G9m8 HOOK. - C.H.B.: 8 O.Y.B.- ommm. A ARZR- C.B.W*Comma= SIAM T01LL. Pw.- FAT05lm. CS.H.a CHORD HBARW. F/L • FROIPH1197T LIITH. LEtimp TYPICAL CT..- CLEAR. R.C.C.- POW OF COIF CWNA. .. C.L.P.- CSS Lite[ SHS. C.A.H - CARAL M HA S. F.C.- FOZSZ OF Com. � OV�D U27&M L=(m C.H.B. - <iTa (CVY). COW.- CSB. FT.- FORA OF 93�Y. '-" - C.L.F. -CHATS LTHK FBaTm:. C.U.F. . COW. OlZLZTY NOW SOC.a FOaR' OF GV1Ml A. F.0.8.a FOZHl OF -�-a-�•- Z.F. - Sam iNWIII i� C.F.- COW. Scam. D.R.C.- FOIIPZ OF R11Y� CWIYH. - y 000 Y.F. - MOOD Ste. 1�8l1Hti HTHYAlZOID. C.B.- BLAB. MY a FARNW. C.Y.- Com law. Pm - FA'iiYRl w R ummm- SLIRVEYOW 8 NOTES' D.H.a'LYAZMM HABMA. F.L.B.: FJM0�8BZIDLL LSI® SODA YLO. D.U.N.- I ZASIalcm. F.F.- Pam POW 1}IPSHOtlN6 ARHRE TOANA98LOAEDNIE3i10WN,8Y8A1DPLAT a"- Darlow. F. F.8. a FOOL FOO BLAB W THE DESCRIPTION OF THE PROPERTY, IF NOT. THEN BEARINGS ARE FOOL D a P.V.N.- PmWC TIrmzw HASEMM TO COUNTY, TOIFlA+RLSWMAPS. ES - 90S (RJ- SiCORD OZBZLV=. 4ALL BEVA71O 0SHONNARE REFERREDTONATIONAL GEODETIC VERWAL DATUM OF B.S.P...sm.m ZC FAD. an RAZZ ROAD. IMPLORIDADEPARTNENTOFTRANSPOR1'AMON RENCH ARK08-23•RA.LOCAT®® �• a 11®8.- HHSzt . U8-1 AND NE 106 STREET: ELEVATION 1723 FEET OF N.O.VD. OF ISM mum.- F.H.: FZRm >im81. HIO . RZO�'-DY-mr. 3L THE CLOSURE THE SURVEY 18 ABOVE 1:7$00 FT. F.I.F.- ram jam rim. RAD.- RADZOT OR Ramm. F ORMATIRY F.Z.R.- FD►AH1 ZH00 ROD a=.- RA . 8.0.8.- low OYBt>�LG FASB'. UNRTHSAGEDONPLATNORTIONLBP7006. 6).NCRTHBASEDONPLATNORiN F.F.H.- F 570011 8131321m. SHC.. 6119220M. F.S.D.a 50WID inn B om. MT.- 81085. Fl.- JZW. Sm.- BIL�4LK. MOVE CERTAWAflON: SSIF.• 5HDT6R" SAncmz zusullwo FROORAY. B.Z.F.. 811! mm FZPH 1itEMYLSRM.,THAT THIS BOL#ZKWBL4Mr OFTNEPRO�PERTYDESCRM HWft F.S.a nm RAIL. H.• MZ� % 8.• am=. /GAS RECFNTLYWMSLOrMWAWORAMI LOOFRMYSJPERVr OMAOC'OMlPL WTH ZS.SMHO.a 2111011130ARD mascm lY'. B.F. • BGiifilID PGWR • THSAWM / TECMC'ILLSTAN00.AOSASSiTFORTHBYTHEFLOWABMRDOF L.H. • Cost>giosb of aoehosisatloa L.H. tg7806 : SiogIDS. ! . !�. PROFESSIONAL LN 17, Apt0tlt5RPA1TYECODE L.F.- LZLW'! FOLH. : 7lT BOOM PURSUANT TOITdOZ7 FLORlliMSTA11JTE3 NTO47240SILORIDYiINTUTMS L.F.R.- Z.MZ ! 510011 HLKISTZON. 28S - TWanTC Sm=LT, 8DH L.U.S.- lift: Millffi saallow. 11111? • 284aw 87fam Fm . ALRv . At/- ASAs�eo Dom. 3AL HOFgS TO ACCOUPANY SKETCH OF •THERE MAY BE EASSWOMRECORMINTHEPUBLICRECORDS#OTSHON ONT?OSSURVEY. • EXAMINATIONS OF THEASSTRACT OF TITLE INCL HAVE TO BEM ADE TO DETEEWWRECORDED INSTRUMSUA IF ANY, AFFECT= THE PROPERTY - THIS SURVEY 13 SUBJECT TO OWWAiMM, LOBTAITONA RESTWCTIONS, RESS?YATIONS OREASEM8WTS OF RECORD • LEOAL DESCIMPTION3 PROVIDED BY CLIENT ORATTEST= TOW COMPANY -6OBVOARYSURVEY MEANS ADRAI T AAWORAGRAPHIC iWR MVTATJONOFTHE SURVEY Kow IN THE FIELD. COUTDBEDRAVA AT A SHON7D SY'.ALEANDTRNOT TO SCALE - EASEi IBM AS SROM ARE PER PLAT BOOK UNLESS OTHERNTSE SHOWN -THE TERM tel' MEANS VISIBLE AND A30WE GROUNDENDWACStOT3. ARCHITECTS SHALL VEX"ZONAB REOUTATIONS, RESTIOCTIONA SETSAC(SAND IMLL BE RESPONSIBLE OF S/Swrm 0 •FLOTPLANS WIN THE CORRECT #W;W WTMFORTHORAPPROVALFORAUTHORZATTONTOAUTiORITIESINANW CONSTRUCTIONS. - UAWSS OlhlMWSENOTED, TNS RlW HAS NOT ATTAIPIW TO LOCATE FOOTINB ANDOR FOUNDATIONS • FENCE ONTMERSW NOT DETERINAkEll • THIS PLAN OF SURVEY, HAS SM PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES AIAMEDIt10tliONL Tiff CERIIACDF. DOES NOT EXTEND TO ANY UlWA1®PARTY. -THE OW FLOOD MAPS HA YEDEMONAITDINEHERON DES OWED LAW TOBESITUATE DINZONE AF COM MUllWTY 1308$7/PANEL 0303/SUFFIX, L DATE OF FhW M WINS BASE FLOOD EIbiVATTOMh 6 FWr THE SUBJECTPROPERTY DOES LIE INASPE=FLOOD HAZMAREA VERONIQUE L.ESTRADE a') o®-7- — VIS / - -- C - INq ar-9;2�-- 05-"2M2 CARLOS /BARBA (VATFOPPIEDWOR19 PROFESSIONAL LAW SLWVlWR NO.: 0770 STATFOFFLORM (VAUDCOPIESOFTHIS SURVEY KULBARTNEEMSOS8 SEAt.OPTHEATTEST W LAND SURVEYOR). mr3EDom. 02-14-2013 REVISED SURVEY Rommow UPDATE 8L ADD CONSTRUCT. ELEV. 0749.2013 REMTSDON: UPDATE &ADD CONSTRUCT. El". 08-08-2013 Romwav UPDATE 01-2E-2014 • Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-207205 Permit Number: BPP -11-12-2265 Inspection Date: February 13, 2014 Permit Type: Pools/Whirlpools/Hot Tubs Inspector: Dacquisto, David Inspection Type: Survey Final Owner: SFARA, VERONIQUE Work Classification: Addition/Alteration Job Address: 1080 NE 105 Street Miami Shores, FL 33138- Phone Number (305)799-2006 Parcel Number 1122320280090 Project: <NONE> Contractor: ALL CONSTRUCTION & DEVELOPERS INC Phone: (786)768-4330 Buildina Deoartment Comments POOL & CONCRETE DECK Infractio Passed Comments INSPECTOR COMMENTS False 3/21/13 bond refunded to landstone builders. New contractor pending to pay new bond. j --(, Inspector Comments Passed �f Failed Correction Needed ❑ Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. For Inspections please call: (305)762-4949 February 18, 2014 Page 1 of 1 777 N.W. 72nd AVENUE SWE 3025 ARAN, FLOA 331M TELEPHONE (3(05) 2-0460 J �.J H 1 V � BA f \ f A & ASS QC . , I N C . SURVEY Afo. 12-0692 7-4 F". (Mi)16Y-Ml D�RAi+Vrw.lbairelandsuroeN BY: MCH. yors.aavn LAND Sr/RVEYOFt5 SHEET No. 2 OF 2 SCALE a 1"= 20' = 1 C=c3Zi�i [ Utdl�.11t Tl :. I S i RU fill At - -- 42.10' — POOL _ 1.21' CL "� ELE ZAL 42.10' 3 3 rUNDER CONSTRUCTION LYPLU SING r` DRAIN BOAT , `���E. 1/2° __... N D LIFT L.B. 7 5OG 1Ir ,r 3 k _ -.�1 t: C''' r ;6tV.L VdTH ALL FEDERAL, 0 1Y RULES AND REGMAT 10NE _.✓ �+ �.-/ .- .J .-/ .-/ .-✓ ._.s" ..»° .. ./ � . ..�� �4Tdi&'7Sk1! AEsc 1��17PLa'.i�t�s SURVEYOR'S NOTE. There may be Easements recorded in the Public Records not shown on this Survey. TTY ASW. 72nd AVENNN SWIN 3M TWANK RAPH MM(3 33019 202 JOHN M ARRA & ASSO:C.gINC. �. ,Z.�,ZM�.. mx rum Zit."" R f — Mfq►tll.�b� . UCH 8JlGWS.CORf %wQ suin om a�AwN BY. BCH sHFETNo. I of s PROPFRTYADDRESS: 1080 N.E. 105th 5TREET MIAMI 5HOWS, FL 33138 LEGAL DESCR001ON: LOT 9, BLOCK 1. Or MIAMI 5HORE5 E5TATE5, ACCORDING TO THE PLAT THEREOF A5 RECORDED IN PLAT BOOK 47. AT PAGE 58, OF THE PUBLIC RECO105 Of MIAMI-DADE COUNTY, FLORIDA. LOCATION SKETCH 'S"Tow." m St !' t�!! i.� _....-.. r pptn _ l r+Ipv !tr Ira r I! t 7-7 k g g - ARC. ASBREWAMNANDYEANM A.C.: ASR �=TSON HAD. 1® m ANLM am sw a T088&R0. A.B.-Amomin BASBILmm. N.D.C.R.- MZKW Amm COMM R800NiD8 OTSL.- DTSLSTY. A.R.- ALD?M1W/ BOTLY'. N.B. - JNLZNZNNAMZ FAsEEW D.N.: UFZLSTY BARN. A.B.- AL KERIK BSD. N.N.- Jtit�. D.P.- D'rIuff sm. ABFN.a A8 RIM. R.A.F. m HO! A FART OF. W.K.- 114= M11202. a.C.m smwx NOVO - RANZONA6 GNOMMUC VA 73M DATWL N.F.- HOOD Lam. BLDG.- Ham. N.T.B.: Nor av simm. N. s.- MW�. B.N,: R NC8 Jam. i $O.a NW® 6B. : N.R.HOOD ROOM'. B.C.R.a RROLL� Comm Lam. O/8 a Qr?mr. W.V'.: RNMEB ULM. B.O.B.: RAM OY Bi' O.N.- OVERHEAD 'comom zm. (W - CiLWLA9ND. O. N.L.a OV iD urzziw ZU0118. ¢ m � &m.C.H.: Ci11C8 RLBtd. O.R.B.: OFFSCiAL LDS BDOII. ME= ABOM. C.B.B.- CONCFBTB BLOL<C O.V'.R.: OYJW. : ARMS. C.B.N.: 9LOtS1 ALL. Li1SfY.: FALo1'. CH - Cum. FL.: FLL nam. CR.B.- CUMLSD. F/L a FR wmr LZON. LEGEND TYPICAL CL.a C M. F.C.C.- FOSNT! OF COPQWID CORVB. C.L.F.- CBS= law simm. F.C.a FOBPr � L358YB. a, Or68dBiD U2714" LL>F8 C.N.B - CANAL JG FT.- FOZOT LP 241122CY. �" C.B.B. - RAMS (Lm �•- SOC .a raw or CNT18 1'. —C.L.P. a CST Li12H7d. C.D.D. - CHOW. DTSLtTY Sm F.O.B.- FOSNT or ZMR 4— I.F. - SRLYT FLLNo. C.P.- Cm. FORM. C.B.- C BLAB. D.R.C.- pow OF REVS CLL m. P•F. - ROOD OYN • 000 - Z . C. N. m C90 aux. MY - FAS211M. Fm - F . SURVEYOR' S NOTES: ZRAZN1TLH FABOP7Pl. F.L.8.- paommSSONAL L:1® D.N.B.a DBiINAdZ F.F.- FOBNR FAWN 111FSH�M68EABUpSARHREF6RREDTOAMA881 D NIERMAN,BYSA0IPLAT mn! - maim". F.F.B.- F000i FOP Pimm INTHELIEL�PRMIOFTHEPROPBRTY,IFIM THEN AREREPERRm ° - LD)i(�B• F.D.B.- am= urzz Y BiBBNLDr TO COLWY,Towpo OPWWB. RB - &LECESMO BOO: (R)- BSD D:B2110010. 4 ALL MEMATICN8 8NOMRr1ARE REFS UM TO NATIONAL GEOMM VERTICAL CATUM OF B.T.F.- 2MCTRSC CRAN91COM FAD. im ANLU RSO, IMFLORIDAWARIN01MOFTRAIPPORTATION SENC7iMARKS8404MJ.00ATED0 zzw.- LdLB1IATd�. Rum RBB. - US -1 AND NE 105 STRUT: ELEVATION 1723 FEET OF N.O.V.D.OF 1878 F.B.a Fm1cR jA R/N : R:fuT-OT-mr. THE TM PWAVrBOUNDARYLI307lfNABOVE17BODFT. F.I.F.- YOM mw 93M. RAD.m RADSDB OB R>1 ". : 4CERT3). IRCAT F.S.R.- � saw am sL awm x. R.O.B.- ROOF 07TLLLDY1 8A8�r. 4NOKIFBATEOFAUTFTMOMNLBi780& 81NORTNBASEDONPLATNORTN F.F.B.- 7TNs8A1� Fla1A BL1t1OTtL8P. 86C.m sLBZi®. F.N.D.a SO= so= 6 DZW. BWY.- 8lORY. AM. eiQ;.- ssoersNr�r. SURYEYOR'SCBRTWXATiO1: - ' LLaTIOm B.E.F.- BLOsI' aLLQR FIPB #mmYcERw.,Tmrflm7i01/mgRY818wr oFT1NPROPFRTYDEBCRIBEDiB F.N.- LLDL® amu. N.- �� [>�OL�1 s.- LNOvm. HAS RECEMLreEENsuazreY�AnloaRal�auara�snsL vrsroasASlocau�L�so MAA.- MISMU88 AM BOBiBS BAB1101100. 8.F. : sconxmw FOHCB ° TNEWMM TECIMMSMUAV XASWTFORMSY7WFiCR=BQMCP L.H.: f:aatLil3oata at AntLoa3aat.Loo L.B.07808 : T m, PROFESSOWLAW SUREVOMWCHAPTER61.17,FlCIMADUMMSM7NECoOE L.F.- Moo SM. SB : lBliF808181 80i0lR PURSUANT` TO4MW..FLOWASTATUINS. Jr.,SORROW MOR RFAULMM. WHO a TRAFFIC 8SOw N'm L.N B.- tili3D suilmommmm BASENRUr. 1w - T NW= Szom Fm M- LL$AsaT�D DEBSNNt'8. LEGAL NOTES TO ACCOMPANY SKETCH OF SIxW tSURVL7" • THEW MAYSE EASEMENTS REODRO W IN THE PUBUCRECOADSNOT SHOWM ON THIS SURVEY. -EKAWNATrONS.OFTNEA83TRA OFMLEVAL HAVE TO BE MADE TO DErSOMFECOWEDINSTIMW01M IFANY, AFFECT= THE PROPERTY. - THIS SURYEYIS SUB/ECT TO 010=1101A L86rATIONB RESTRfCTIONS, RESERVATIONS OREA39NENTS OF RECORQ •LEGALOESCFW"W t3AROVWWBYCL9WrORATTESTNfoTITLECOL~. -BOUNDARY SLOW MEANS A DRWW ANY OR A QWMC REPRESWATONOFTHESLVIVEYWORXSINTHE FIBD, COULDBEDR4MATA SHOWN SCALEAMMMAPDT TO SCALE -EASEAffNTS AS SHOWN AREPER PLATSOCI( UNLESS OTAMNSE SHOWN. -TIN TERM'>S BIENT'MEANSVIMBLEANDABOVEOROUAIDENCROACHUSNIS MCNTECTS SHALL YL30FYZONOVO REOWATIOWS, RESTRICRON$ SETBA =AND WALL BERESPONS(BLE OF SUBLBTTINB PLOT PLANS WIN THECORRECT INFORMATION FOR INERAFPROVAL FOR AUIHO WATION TO AUTHONnES IN ANEW CXIIPTRUCTI0N6 . UNLESS OTHEWSENOTEIZ TNS FMU HAS NOT ATrEMPi'mTo LoCATEFooT/NOANDIDR FoL%=nm - PENCE OMXERSW NOT DETERNBAM •THIS PLAN OF SURVEY, HAS BEEN PREPARED FOR THE EXCLUSIVE USE OFTIE SKMESNOMWf OALTHECERTIRCATE DOES NOT EXTEND TO ANY UAWAN ED PAM Y. -THE NRPFLOOD MORS NAWEOENGMTEDTHE HOMDESCNSW LAND TOBESITUATmINZONE' %1E' COM OM 120332/PANEL OM/SLffFOCLDATE OFFMt08 WOM BASE FLOODELEVATmw a FEET THE SMELT PROPS W DOES UE INA SPECIAL FLOODHAZARDAREA CERnRCATM. VERONIGUE LESTRADE er. 05-04.2012 CARLOS IBARRA mAyEoFFLFtDWORIQ PRO.'S3IONN.LAW SLRVEYORNo- 3770 STATEOPFLOR07A (VALLD COPB� OPTHW BLLRYEYRDJ. Bf�' OR flLESFAL.OP iHEATTE81LN0 LAND SURVEYOR} mm molt 02-14-2013 REVISED SURVEY awa m UPDATE S ADD CONSTRUCT. ELEV. 07-09-2013 mv,w ON• UPDATE 81 ADD CONSTRUCT. ELEV. ONWM13 Dov UPDATE 01-29.2014 LS Seno STATE OF Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-196011 Scheduled Inspection Date: September 26, 2013 Inspector: Rodriguez, Jorge Owner: SFARA, VERONIQUE Job Address: 1080 NE 105 Street Miami Shores, FL 33138 - Project: <NONE> Contractor: ALL CONSTRUCTION & DEVELOPERS INC suuaing Department comments POOL & CONCRETE DECK 3/21/13 bond refunded to landstone builders. New contractor pending to pay new bond. Permit Number: BPP -11-12-2265 Permit Type: Pools/Whirlpools/Hot Tubs Inspection Type: Pool Deck Work Classification: Addition/Alteration Phone Number (305)799-2006 Parcel Number 1122320280090 INSPECTOR COMMENTS False Inspector Comments Phone: (786)768-4330 Passed CREATED AS REINSPECTION FOR INSP-195724. CREATED AS REINSPECTION FOR INSP-182251. Only WF -36 Footings Not ready Failed C�,rOr�'r�•v r—��s�.� Correction Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. September 25, 2013 For Inspections please call: (305)762-4949 Page 5 of 34 GEOTECHNICAL j f-�r. �r�.� ��j�w�y® MATERIAL I ES I NG ENVIFIONNIMAL int �L':s t+t/L \Lc y�e'1 C SERVICESASBESTOS ROOFTESTING DYNATF,cH ENGINEERING CORP. Miami, September 18, 2013 Ms, Veronique Sfara 1080 NR 105' Street Miami Shores, FL 331.38 Re: Proposed Pool Deck @a 1080 N.E. 105" Street Miami Shores, FL Dear Ms, Sfara: Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on September 18, 2013 at the above referenced project. DEC was authorized to perform a compaction test only. The purpose of our test was to determine the degree of compaction of the tested layer of material only: In no way shall a compaction test replace a demuckng inspection, soil bearing capacity determination, or a pad certification. A sail boring test must be performed by client if not yet done, prior to construction to verify subsoil conditions. Our findings are relative to the bate and areas of our site work and should not be relied upon to represent conditions on other areas or dates. Any subsequent site disturbances due to water erosion, rain, construction activities, excavations, overgrown, vegetation, traffic and other disturbances will void this test and the site must be re -compacted and re -tested prior to construction. Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is required, we can provide a proposal for performing an environmental analysis of the soil materials. No other analysis is implied or warranted. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Enclosed find copies of the compaction test -results. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours, Wissa Naamani, P.E: DYNATECH ENGINEERING CORP: Florida Reg. No. 39584 Special inspector No. 757 Certificate of Authorization No.: CA 5491 150 West 84 Street, Hialeah, FL 33014-3618 Phone: (305) 828-7499 • Fax: (305):828-9598 B_ Maih Dynatech@a bellsouth.nd DYNATECH ENGINEERING CORP. 750 WEST Se STREET HIALEAH, FLORIDA 33014 (305)828-7499 PROCTOR COMPACTION TEST DATE: So ember 18.2013' CLIENT: MS. VERONIQUE SFARA PROJECT; Proposed Pool Deck la, ADDRESS: 1080 N.E. 105'h Street Miami Shores FL. - -- CONTRACTOR: Ms. Veronique Mara MATERIAL DESCRIPTION: Brown sand w/rock fra=ents SAMPLED BY: RN TEST RESULTS TESTED BY: RN Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations ofsoil using a 10 lb. Hammer and an 18" drop ASTM D -t 557. % MOISTURE 6.4 7.1` 7:s 11.0 DU DENSITY 110.0 111.2 i11.9 109.0 Optimum Moisture 8.4 Percent I W1. Maximum Dry Density 11 16s,Jcu h.. % Passing =1." Sieve 89 Percent Certificate of Authorization No.: CA 5491 T ',i�:is,q 04 - 4. Sampled By RN �N" .* �.s Tested By: RN Checked Ay- RN y{ o ;� �'t " < 4 6 6 $ 10 12 14 a % MOISTURE �n =m � C Respcetively submi As a mutual protection to clients. the public and ourselves. all repei�s fkll S 9 ALA are submitted as the confidential property orctienls. and authorizati,-w ` g _ titr use, in"ication of statements. conclusions or extracts from or regWl' "' `* Wissarn Naamani, P.E. our reports is reserved pending our written appmva- 'V//t h DYNATECH ENGINEERING CORP. Florida Reg. No, 39584 Certificate of Authorization No.: CA 5491 T DYNATECH ENGINEERING CORP. 750 WEST W' STREET HIALEAH, FLORIDA 33014 (305) 828-7499. FIELD DENSITY TEST OF COMPACTED SOILS DATE' September 18 2013 CLIENT:. MS. VERONIOUE SFARA NOTICE OF TERMITE PROTECTIVE TREATMENT AS REQUIRED BY FLORIDA BUILDING CODE (FBC) 104.2.6 As PER 104.2.6 -IF SOIL CHEMICAL BARRIER METHOD FOR TERMITE PREVENTION IS USED, FINAL EXTERIOR TREATMENT SHALL BE COMPLETED PRIOR TO FINAL BUILDING APPROVAL. DATE OF TREATMENT: 9 k8 13 Tnvm OF TREATMENT: IN 1'40 -"aO APPLICATOR' A OUT BUILDER NAME: FA - TREATMENT ADDRESS: (0 50 Auo - to s JOB #: LOT: SPRAY & TAMP QPRAY ONLY SPRAY # CHEMICAL �C� CHEMICAL: BLOCK: UNIT: RESIDEN COMMERCIAL DITIO -------------- CD ` L% �) ! GALLONS STEMWALL STAGE OF TREATMENT (HORIZONTAL, VERTICAL, ADJOINING SLAB, RETREAT OF DISTURBED AREA) DATE OF TREATMENT: PERIMETER TREATMENT TIME OF TREATMENT: LT APPLICATOR: SF GALLONS 300 S. STATE Roan 7 PLANTATION, FLoRmA 33317 954-584-8588 1-800-749-8588 FAx: 954-584-6117 L/F Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NVMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING L� M r FEB 2 0 2013 C 20 ! Permit No.M12L�22_(OT Master Permit No. ROOFING JOB ADDRESS: l eo /V d` t; ®- City: Miami Shores County: Miami Dade Zip: 33/3,4.3 Folio/Parcel#: Is the Building Historically Designated: Yes NO We Flood Zone: OWNER: Name (Fee Simple Titleholder): X eST3^,*C% S X4 /c® Phone#: Address: 149,W 4 M city: State: Zip: 6 Tenantlzmee Name.• Phone#: CONTRACTOR: Company Name:./XII e a e d r, -e KY1 /,i t - Phone#: 4�' - V .-2 T ..z Address: Xde) a Ate: State: Zip: 31 2 Qualifier Name. e7 , ,-,e ��Y Phone#: �) 40 )Q,LS Z3 r� State Certification or Registration#: Vii` Q�4� -16134,6"l Certificate of Competency Contact Phone#: 30-5 Ael-I Email Address: !t , `. .'P, :77, ,,,,Ct cse` &11o:7,r,d`e Co,3, DESIGNER: Architect/Engineer. 4 ,,_P C,, a ; a - Phone# 30S-7- Y,� d Value of Work for this Permit: $ 7 J Square/Linear Footage of Work: of = ,ko Type of Work: OAddition DAlteration iew ORepaidReplace ODemolition Description of Work: C 6 ^ Cer-1� . Aeck e, ton c Color thru tile: Submittal Fee $ Permit Fee $ _TS - Q 0 CCF $ Co/CC $ Scanning Fee $ Radon Fee $ Notary $ TraftftWEdncation Fee $ Double Fee $ Structural Review $ DBPR $ Bond $. Technology Fee $ TOTAL FEE NOW DUE $ .. v , rir �.�. •�. .. ... _. ,. .,a . . i ' r Boning Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City state Zip Zip Application is hereby mace to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EMPROYEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a cernfied copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged oe SignatmrX S /H • Owner or Agent a The fbrepmf instrument was acknowledged before me this d day of &A. . 20 L3 , by ` who is personally known to me or who L produced R e—t 0*4 jf�06 Q1,4 As identification and who did take an oath. NOTARY The foregji7t was acknowledged before me this/g day of 'r .20&1 by �'1 • CO r✓� , who is personally known to me or who has produced & k b I-001 as identification and who did an oath. NOTARY 0, r Sign: Print: ,� re , a, h a `14 My Commission Expires-AWA"RA Bl l" My Commission Exp' SR1T0 � Ju81102014 >te Commission # DO 100 =min tOsi1" i~� oa o Structural Review Clerk (Revised 3/1=012XRevised 07/100 OWvised 06110/2009)(Revised 3/15/09) FJ A:Rgfttj,;A Mal "t ou 4 6411SIPSO-3 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CHANGE OF CONTRACTOR I ARCHITECT Permit N. Owners Name (Fee Simple Title Holder):0 Phone #: Owners,Address: 9 City: !m , rD s State : F Zip Code: Job Address (Of where work is being done): Zi96& IVC 106--4 6-74 City: Miami Shores State:—Florida Zip Code: 3 13 I5"Y fl 63 6y' Contractors Company Name: Phone #: Z& Address: /000 — s �" City: -r / State: eC�L Zip Code: 33131 Qualifiers Name: Q Lie. Number: C6 Architect/ Engineer of Record Name:da lc- .0 Phone #: -4dr - Y`-2 9 BB,0v Address: lv5YO IveV c>90 -sr & 6'- il>a— city: A/zt?"0'7z` tate: /:;::f Zip Code: .3-4 i 9d, Describe Work:X-410 .dim r�-i ,25 aOO / .e V4; ?'vv c.7t e „ I hereby certify that the work has been abandoned and/or the contractorlarchitect is unable or unwilling to complete the contract. I hold the Building Official and the Miami Shores harmless for all legal involvement. Signature Sig ure �.v,A owner or Agent Contractor or Architect The foregoing instruqient was akno ledge before me The foregoing instrument was aknowledged before me /A this/ 4 -day off ,201> 1, - +vim—this � day of �, 20/jby y C� d✓- Who i personally known me or who has produced wl�6 is personallnown to me or who has produced as indentification. i�L.S O �I j&AI &A%// as indentiflcation. Nota D S Sign: p � Seal: v. Cugtt CLPucIR l Florida ,,., NotatY PUhlic esaSep 23, 2015 Cumfilssion # EE ota$Y Assn Com ionalN h10,,%% bonded Thtou9 Notary P li Sign: c: ' 2 " /�= up �3 O Seal:AriD1�B .Std Ca DDi�pp$41 BUENA VISTA STATION NIANI, Florida 331379998 11S85401C� -0096 02/11x"2013 (800)275-8777 12:25:07 PN Sales Receipt Product Sale Unit Final Description qty Price `Price AIANI FL 33155 Zone -0 $0.46 rirst-Class Letter 0.50 oz. Expected Delivery. Tue 02/12/13 Return Rcpt (Green Card) $2.55 @@ Certified $3.10 Label #: 70121010000007133129 Issue PVI: $6.11 5 00 5 $(;.10 !;1u.k r"ih 1ota1. Paid by: Debit Card Account #, Approval #: TransaCt1Ui. # 23 90352056/ Receipt#: $11.61 XXX XXk.t % i v,XX636t, 011718 458 @@ For tracking or inquiries go Lo USPS.com or call 1-800-222-1811.. Order stamps at usps.com/shop or call 1-800-Stamp24. Go to usps.com/clicknship to print shipping labels with postage. For other information call 1 -800 -ASK -USPS. Get your mail when and where you want it with a secure Post Office Box. Sign up for a box ,oline at usps.com/poboxes. Bill#: 1000403962292 Clerk: 18 All sales final on stamps and postage Refunds for guaranteed services only Thank you for your business HELP US SERVE YOU BETTER Go to: https://postalexpari,.ence.coinlPos TELL US ABOUT YOUR RECENT POSTAL EXPERIENCE YOUR OPINION COUNTS Customer Copy ■ Complete items 1, 2, and 3. Also complete Item 4 If Restricted Delivery Is desired. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card taw the b(Lek of the mailplece, or on the front if space permits. 1. Article Addressed to: 1 Ce) C� J hQA V•us( AeAAA- 00- A ' A.;711. X ❑ Agent ❑ Addressee B. ed by (PHnIed Name) C. Date of Delivery M IOU [I z % L U 3 E D. Is delivery address different from Item 17 ❑ Yes if YES, enter delivery address below: O No 3. Service Type p corBRed Mail ❑ Express Mall p Registered ❑ Return Receipt for Merchandise 1 ❑ Insured Mail ❑ C.O.D. 4. Restricted Delivery? (Extra Fee) ❑ Yes 117 ru r -i M IOU [I z % L U 3 E M r%- Postage C3 Certified Fca C3 C3 C3 Return Receipt Fee (Endorsement Required) Postmark Here c c ` ° C3 Restricted Depvery Fee (Endorsement Required) - i pC3 Total Postage 8, Fees Sent �Yl J ®1f1� � � Pl7Box �P--•��� ---�— ° - :,,2006 See Reverse for InStRICUOIIS r Delivery Record: DI NC007-717 TW7- Date: 02/14/2013 Dear Postal Customer: Page 1 of 1 In response to your request dated 02/14/2013, we regret to inform you that we were unable to locate any delivery information in our records regarding your item number 7012 1010 0000 0713 3129. If you require additional assistance, please take this receipt to your local Post Office or postal representative. Sincerely, United States Postal Service https://pts.usps.gov/pts/requestDelivery.do?displayLetter=Y&eventLocation... 2/14/2013 Track/Confmn - Intranet Item Inquiry Track/Confirm - Intranet Item Inquiry - Domestic USPS employees are able to view proof of delivery letters that are incomplete (e.g. no signature, too early for delivery) through the Intranet. If a signature is not appended to the record and It is less than 7 days since delivery, you may wish to request that the POD letter be sent to you via e-mail, fax, or mall rather than viewing the letter and printing It from the Intranet. Viewing and printing the letter directly from the Intranet may result in an incomplete proof of delivery letter. See Handbook PO -610 for information on Intranet (and Internet) access to records. Request Delivery Record for 70121010000007133129 First Name' Veronique Last Name Sfara For delivery via FAX: r For delivery v4p Email: r Fax#: Email Address: (numbers only) For delivery via the mail: r Address: 1080 NE 105 Street l City: Miami Shores State: FL ZIP Code + 4: (Find ZIP+4 or ZIP Code/Gifu association) Submit Reset-_ Return ko I$em Swmmar Show Delivery Record for 70121010000007133129 Enter Request Type and Item Number: Quick Search & Extensive Search j70121010000007133129 P_Submt Version 1.0 Inquire on multiple items. Go to the Product Tracking System Home Page. Page 1 of 1 https://pts.usps.gov/pts/requestDelivery.do 2/14/2013 Direct Query - Intranet - "Quick" Search Page 1 of 1 a Track/Confirm - Intranet Item Inquiry - Domestic . . You entered: First Name: Veronique Last Name: Sfara Address: 1080 NE 105 Street City: Miami Shores State: FL Zip Code: 33138 Address Validation: We have found a preferred address based on the information you entered. Name: VERONIQq5 SFARA Address: 1080 NE 105TH ST City: MIAMI SHORES State: FL Zip Code: 33138 - 2106. Agcept Recgmmerldatibn ; , L Ig',nore Recommendation Go Back ' � Enter Request Type and Item Number: Quick Search Extensive Search � yti�rrt ��4uicic'�id Ext�enslwe'�'` ; _Submit Version 1.0 Inquire on multiple items. Go to the Product Tracking System Home Page. https://pts.usps.gov/pts/requestDelivery.do 2/14/2013 rj" l NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITEATTIME OF FIRST INSPECTION 2 ("'j � PERMIT NO. <��O' AX FOLIO NO. t`'�°�� �� �O STATE OF FLORIDA: COUNTY OF MIAMI-DADE: THE UNDERSIGNED hereby gives notice that ;improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided in this Notice of Commencement 1: Legal description of props and streeVaddress: ® Iq ti 181 .� 2. Description of improvement 3.Owner(s) name and address: Interest in'property: Name and address of fee simple titleholder 4: Contractors name, address�rtd phone numbtt 5. Surety: (Payment bond required by ownWfrom contractor, If any Name, address and phone number iy Amount of bond $ 6. Lender's name and address: a 7. Persons within the State of Florida designated by Owner upon m Section 713.13(1)(6)7., Florida Statutes, Name, address and phone number. sV OR Bk 28470 F'9 3336i Q P 9) RECORDED 02/0112013 I0:25:49 HARVEY FUVINY CLERK OF COURT MIAMI—BADE COUNTYr FLORIDA LAST PAGE Space above reserved for use of recording office r+ 1-, M served as B. In addition to himself, Owners designates the following person fs) to receive a copy of the Lienor s No ce as provided in S 713.13(1)(b), Florida Statutes. Name, address and :phone number: 9. Expiration date of this Notice of Commencements N (tire expiration date Is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY -THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS, UNDER CHAPTER 713, PART (, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY'.'A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signatures) of Ow r(S) urr3er(sC" ri ed.Officer/Director/Partner/Manager Prepared i3y _ Prepared By Print Name Print Name Title/Office Title/Office STATE OF FLORIDA COUNTY OF MIAMI=BADE r The fo Ing instrument was acknowledged before me this day of 1 '�—(( �Lc� , t By �2�;:v 454ndividualiy, or ❑ as for strut tup� 'i ersonally known, or ❑ produced the follow1hg type of identification: ��� ' Signature of Notary Public: ® '� Print Name: •'' 1 LVr GO (SEAL) VERIFICATION PURSUANT TO SECTION ORI Under penalties of perjury, I declare that I have read the foregoing and% that the facts stated in It are true, to the best of my knowledge and bel�f� •. ��,��` �' `\�� Signatur° ,) of er(s)'s Authorized Officer/Director/Partno .. O /A�r}ri��b �i�tl above: unnnitu BY BY 123.0152 PAGE 3 3l10 re S NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION 1"" PERMIT NO. JH 1 FOLIO NOA (2_ p _ STATE OF FLORIDA: COUNTY OF MIAMI-DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided In this Notice of Commencement. 1. Legal Oe§cription of properly and 2. - t - 3.Owner(s) name and addres Interest in property: Name and address of fee sim 4. Contractor's name, address and phone number. CFiii{ 2013R� � 144513 OR Sic 28501 Ps 13661 t 1Pe ) RECORDED 02/22/2013 11:33:14 HARVEY RUVIN? CLERK OF COURT MIAMI—DADE COUNTYr FLORIDA LAST PAGE Space above reserved for use of recording office 5. Surety: (Payment bond required by owner from contractor, if any) ' Name, address and phone number. Amount of bond $ d4 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(i)(a)7., Florida Statutes, N / Name, address and phone number. 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number. 9. Expiration date of this Notice of Commencements (tire eWmUon date is 1 year from the date of recording urdess a different date is spec fled) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE. OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YdU INTEND TO OBTAIN FINANCING, CONSULTr} W gO y FORE COMMEt '.t Cr1NORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.r �, 9 f go -9i3 � �d� ar�€t this 13 a fare MY ofthe Signature(s) of er(s) orQwner(s)' Autho Officer/Director/P,9- [Ma'm,&*09,i.ee en edayaf Prepared eb B Print Name PV hand sand o `cicd Sea9. �.,q� s Title/Office Tract UViWAIC u"�u�9 ', STATE OF FLORIDA COUNTY OF MIAMI-DADE The foreg i ant c I me this c(auy f `F �® t gy V d P, ❑ Individually, or Ilk as for Personally known, or ❑ produced the following type of identifica n Signature of Notary Public: g., Print Name: CL _nUiorida g Notary ( �° My romm Expires Sep 23.2015 VERIFICATION PURSUANT TO SECTION 92525 FLORIDA STATUTES e3 . �,. Commission # EE 128810 Under penalties of perjury, I declare that I have read the foregoing and �'' that the facts stated in It are true, to the best of my knowledge and belief: '�.;,1;,;,;.Bonded Through National Notary Assn• Signatur s) f er(s) or Owner(s)'s Authorized Offlcer/Director/Partner/Manager who signed above: By By 123.01-52 PAGE 3 3l10 - }. Miami Shores Village a j Building Department��' 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 - Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 20 110 BUILDING Permit No. PERMIT APPLICATION Master Permit NoIYFrA -aa6s Permit Type: BUILDING ROOFING UO SS: C) � C)�f 0� 5t City: Miami Shores County: Miami Dade Zip: Foho/Parcel#: Is the Building Historically Designated: Yes NO Flood Zone: r Q� SER: Name (Fee Simple Titleholder): e,� 6 ra Phone#:3>Qs 'T6? 9 2� 6 Address: INO I V City 'i QV_9 State: L Zip: Tenant/Lessee Name: Phone#: Email: C TRACTOR: Company Name: ����� S�-� 1 010f Phone#: 50 52(2D 14 B I9 ro) Address: 0S I v 09t4--mu),�? 21 Dr #?,oli City: �l PS State: gip; 1 Qualifier Name: Ca mytl of cA I l o Phone#: ' oco Q(0 S { �j State Certification or Registration #:C_rr,,,�� /� SM 6 1 Certificate of Com etenc #: Contact Phone#: Email Address: kP l U Vl hZ eo l at Motto o alt ows' . Cq ICE'S GNER: Architect/Engineer Phone#: 4 daiue of -Work for this Permit: $ �f ®®� Square/Linear Footage of Work': Type of Work: ❑Addition OAlteration _ ONew ORepair/Replace ODemolition tion of Work: Color thru tile: zi Submittal Fee $-,20,_ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond Technology Fee $ TOTAL FEE NOW DUE $ 1P M '� Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is is ued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature__�2 Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this dayof LIQ, ✓,201?,by�ZUl(M\QJZ-S(--,SaA, who is personally known tome or who has producedL t As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: vo The foregoing instrument was acknowledged before me thisl day of 20 b c3 who is personally known to me or �h� zif�pro uced� as identification and who did take an oath. NOTARY PUBLIC:`\�e. � p 11 �''''%, APPROVED BY / '�� Plans Examiner �"7-1 ro `✓ Structural Review Sign: Print: My Commission Expires: (Revised 5/2/2012)(Revised 3/12/2012) XRevised 06/10/2009)(Revised 3/15/09)(Revised 7/10/2007) %v'�'6EE113 inns Zoning Clerk L� Ui LLl4'Ll sONe6 10050 N.E. SECOND AVE. MIAMI SHORES, FLORIDA 33138-2382 Telephone: (305) 795-2207 Fax: (305) 756-8972 DAVID A. DACQUISTO, AICD PLANNING & ZONING DIRECTOR DEVELOPMENT ORDER Fite Number: PZ -6-12-201222 Property Address: 1080 NE 1056 Street Property Owner/Applicant: Veronique Sfara Address: 1080 NE 105t' Street, Miami Shores, FL. 33138 Agent: David Morton Address: 4444 SW 71st Avenue #103, Miami FL 33155 Whereas, the applicant Veronique Sfara (Owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Special site plan review and approval. Addition, waterfront development and Sec. 51, 8 (b) : Fences in the front yard. Whereas, a public hearing was held on July 27, 2012 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted for a 5 foot wide and 23 foot long wood walkway/deck to be located within 5 feet of the rear plot line. 2) Approval is granted for a 3 foot 6 inch masonry fence along the front plot line and a 3 foot 6 inch ornamental metal fence along the side plot lines within the front yard. Page 1 of 2 DO PZ -6-12-201222 Sfara amended 3) Approval is granted for an ornamental metal gate (wrought iron style) in the front yard along the front plot line. 4) Applicant to obtain all required building permits before beginning work. 5) Applicant to obtain all required permits from the Department of Regulatory and Economic Resources, Environmental Plan Review Division. 6) Construction shall be in full compliance with FEMA regulations. 7) Applicant to meet all applicable code provisions at the time of permitting. 8) The architect to certify to the building official that the site provides storm drainage that detains the first one inch in natural or filtered structural facilities prior to the issuance of a building permit. The applicant is responsible for any site modifications that are or may become necessary to provide storm drainage that detains the first one inch in natural or filtered structural facilities and shall make site modifications as necessary to prevent runoff into neighboring properties. 9) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. The application with conditions was passed and adopted this 27th day of July, 2012 by the Planning and Zoning Board as follows: Mr. Abramitis YES Mr. Busta ABSENT Mr. Reese YES Mr. Madsen YES Chairman Fernandez YES zc>! -2-- Date Page 2 of 2 DO PZ -6-12-201222 Sfara amended DAVID A. DACQUISTQ, AICP PLANNING S ZONING DIRECTOR DEVELOPMENT ORDER 10050 N.E. SECOND AVE. MIAMI SHORES, FLORIDA 33138-2382 Telephone: (305) 795-2207 Fax: (305) 756-8972 DACQUISTODOMIAMISHORESVILIAGE.COM File Number: PZ -8-11-2011257 Property Address: 1080 NE 105th Street Property Owner: Veronique Sfara Address: 1080 NE 105th Street, Miami Shores FL 33138 ApplicantlAgent: David Morton Address: 4444 SW 71" Avenue #103, Miami FL 33155 Whereas, the applicant David Morton (Agent), with the consent of Veronique Sfara (property owner),has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Pursuant to Articles IV, V and VI of Appendix A Zoning, Special site plan review and approval ,for a second story addition including 2 bedrooms and 2 baths, and for waterfront development of a deck. Whereas, a public hearing was held on September 22, 2011 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted to expand an existing residence and to add a second story 2) Approval is granted to install a pool, pool deck and wood deck as shown on the approved plans Pagel of 2 DO PZ -8-11-2011257 Sfara 3) The architect to certify to the building official that the site provides storm drainage that detains the first one inch in natural or filtered structural facilities prior to the issuance of a building permit The applicant is responsible for any site modifications that are or may become necessary to provide storm drainage that detains the first one inch in natural or filtered structural facilities and shall make site modifications as necessary to prevent runoff into neighboring properties. 4) Driveway to be redesigned to meet zoning code requirements for design and construction prior to the issuance of a building permit. 5) The section of the driveway that serves as a stair landing must be reduced in `width to 3 feet. b) Applicant to secure DERM approval for the davits, if necessary. 7) Applicant to secure necessary DERM or Department of Health approval for the septic system prior to the issuance of a village building permit 8) Applicant to obtain all required building permits before beginning work. 9) Applicant to meet all applicable code provisions at the time of permitting. 10) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. Additionally, the applicant must, satisfy all applicable Miami Shores Village Codes, Miami -Dade County Codes, the applicable building and life safety codes required for development, and provide a copy of the development order to the Building Dept. The application with conditions was passed and adopted this 22nd day of September, 2011 by the Planning and Zoning Board as follows: Mr. Abramitis Yes Mr. Busts Yes Mr. Reese Yes Mr. Madsen Yes Chairman Fernandez Yes Date Xiehard M. Fernanz Chairman, Planning Board Page 2 of 2 DO PZ -8-11-2011257 Sfam e y�ott�s �iate tat.a�Miamt loreJ t 0R9DP 10050 N.E. SECOND AVE. MIAMI SHORES, FLORIDA 33138-2382 Telephone: (305) 795-2207 Fax: (305) 756-8972 DAVID A. DACQUISTO, AICD DACQUISTOD®MIAMISHORESVILLAGE.COM PLANNING 6 ZONING DIRECTOR DEVELOPMENT ORDER File Number: PZ -6-11-2011254 Property Address: 1080 NE 105'th Street Property Owner/Applicant: Veronique Sfara Address: 1080 NE 105* Street, Miami Shores FL 33138 Agent: David Morton Address: 4444 SW 71't Avenue #103, Miami FL 33155 Whereas, the applicant Veronique Sfara (Owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Pursuant to Articles IV, V and 1V of Appendix A Zoning, Special site plan review and approval ,for a second story addition including 2 bedrooms and 2 baths, and for waterfront development of a deck. Whereas, a public hearing was held on May 26, 2011 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted to expand an existing residence and to add a second story 2) Approval is granted to install a pool, pool deck and wood deck as shown on the approved plans 3) The architect to certify to the building official that the site provides storm drainage that detains the first one inch in natural or filtered structural facilities Page 1 of 2 DO PZ -6-11-2011254 Sfara prior to the issuance of a building permit. The applicant is responsible for any site modifications that are or may become necessary to provide storm drainage that detains the first one inch in natural or filtered structural facilities and shall make site modifications as necessary to prevent runoff into neighboring properties. 4) Driveway to be redesigned to meet zoning code requirements for design and construction. S) The section of the driveway that serves as a stair landing must be reduced in width to 3 feet. 6) Applicant to secure DERM approval for the davits, if necessary. 7) Applicant to secure necessary DERM or Department of Health approval for the septic system prior to the issuance of a village building permit 8) Applicant to obtain all required building permits before beginning work. 9) Applicant to meet all applicable code provisions at the time of permitting. 10) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. 11) The wood deck is not part of this approval, nothing in this approval shall grant approval for improvements beyond the property boundaries. The application with conditions was passed and adopted this 28h day of July, 2011 by the Planning and Zoning Board as follows: Mr. Abramitis Yes Mr. Busta Absent Mr. Reese Yes Mr. Madsen Yes Chairman Fernandez Yes �'� l/ Date Chairman, Planning Board Page 2 of 2 DO PZ -6-11-2011254 Sfara Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 NOTICE OF REQUIREMENTS RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at —A 8 R co N E t n`:;; !Sc; Miami Shores, FL, and hereby affirm that one of the following methods will be used to meet the requirements of Chapter 515, Florida Statues and the Florida Building Code R4101.17. Please initial the method(s) to be used: The pool will be equipped with an approved safety pool cover that comp lies with ASTM F1346-91. (Submit Manufacturer's Specifications). A continuous, one-piece (child) barrier meeting the requirements of Florida Building Code R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location and method of attachment, including one end that shall not be removable without the aid of tools. (Submit Manufacturer's Specifications). A combination of non -dwelling walls and fences (screen enclosure, child fence, masonry fence walls, chain link or wood fence, etc.) will protect t he pool perimeter. The plans must specify t he type and locati of all non dwelling walls. Florida Building Code, R4101.17.1 Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all windows and doors will be equipped with exit alarms complying with Florida Building Code, R4101.17.1.9 (Submit Manufacturer's Specifications). Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all doors will be equipped with a self -latching device with positive mechanical latching/locking installed a min. 54° above the threshold. If this option is selected, submit plans showing all types and location of all perimeter protection. The plans must also show the location and type of all openings, and the hardware type for each location. (Submit Manufacturer's Specifications). In accordance with the Code, the pool may not be filled with water without compliance with the Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be presumed to be unsafe. I understand that not having one of the above installed will constitute a violation of Chapter 515, F.S ., an d will be considered as committing a misdemeanor of the second degre , punishable as provided in Section 775.082 or Section 775.083 F.S . This form must be signed by th o edagent and the prime c or. U,CTOR'S SIGNATURE AND DATE OWNER'S SIGNATURE A D DATE I-iZ�1"1121 (1 P ,S Q�l CONTRACTO 'S NAME (P SE PRINT) OWNER' ME (PL SEP INT) ui NOTTRY PUBLI9-` �xD res''••?' 03106/2016N Ty Public 0 ' NOTARY PUBLIC v °p � Egana da a Y mission DD9408e1 . Commission # �ovtao� Expires 11/18/2013 /1, 4F OF l:\p /autilitIV 11 ADA tT 402,� t/K.i tam ® L4 -r Dl`s C n 7 Act, i I &tom bude I>I VU (U (� (v T- - 02!01!2013 14:05 3052648996 LANDSTONE BUILDERS 1 PAGE 04/06 LANDS -2 OP ID., SH CERTIFICATE OF LIABILITY INSURANCE DA 19126/7 �1 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CE"FICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. TMM (.1FpTIFICATF--' Or lid-WRANCP 11OFS NOT CnNSTITIITF A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certlticcate holder Is an ADDITIONAL INSURED, the poiiey((as) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this Certificate does not confer rights to the certlffeato holder in lieu of such endomeme s . PRODUCER 854-731-9566 lNE CT W.F. Roemer Insurance Agoncy — -• 4752 W. Commierclal Blvd S5A.737.$A3$ - N ; �UAAIxQ,.I!o1 Fort Lauderdale, FL 33319 E•MA14 Willlam F. Dowd III nDDDrie.4sl INSUREM AFFORDING COVERAQE NAIO S IN5URCI1 A: A3**clation Insurance Co. 112.40 INsuRF.c 1005Landt Waterway erway DBuilders ive INSURER e: Mid -Continent Casualty Co 23418 7005 N Waterway Drive ;Re 304 - - ••-•-� Miami, FL 33155 INSURER c 1 INSURER D; INSURER a: »^ INSURER F r CdVEiae[aFS rtmoTielrATe enuAeMs. ................�-.... THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTVIITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY GE IGGUED OR MAY PERTAIN, TIM INGURANCC ArronoED DY THC VOLIOICE DC601419E0 HEREIN IE SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH -POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED SY PAID CLAIMS. '.. INERAWL jow TYPE OF INSURANCE POLICY NUMBER EFF PMA (MMM YFJIP LIMITS OCNERAL WAnILnY EACH OLCURR a 11000,00 B 3 COMMERCIAL GENERAL LIABILITY 04GL000885158 12=2 12MV13 pREMIS�Q{P� S 100, CLAIM -0 -MADE Q OCCUR MED EXP CAlry Qr* PeMvn) S Excluded] PERSONAL& AUV INJURY 8 1,000,0001 - GENERALAGGREGATE S 2,000, GEML AGGREGATE LIMIT APPLIES PER! PRODUCTS - COMP/OP AGO S 2,000,00 POLICY PRO. LDC S AUTOMOBILE WABILITY IWA.ELIM41 I 1,000,00 A AWYAUTO i'sL0008B51$6 12122.112 1MM3 BODILY imuRY(For pe=) s I ALLOWNED SCHEDULED BODILY INJURY (Per Bedded) S ~ ALTOS I AUTOS X NON"OWNED HIRED AUTOS X AUTOS PR . S { d UMBRELLA IJA9 OCCUR EACH OCCURRENCE S EXCESS LIAR CLAIMS -MADE A[LOREtiATE S 080 I IRETUTIONS = WORKERS COMPENSATION WCSTATU. Tho A AND EMPLOYERS• LIABILITY YIM E,L. EACH ACCIDENT $ 1,000, ANYh:REFVM OEOPRIETOR CKGLUDLO7 MARTNMVD(SCUTIVE 1 NIA x02140505 05/21/12 05/21/13 {ARentlaLOly In NH) F yes d=P gESCRIPTION OF OPERATION6 tftW E.L DISEASE . EAEWnOYE S 1,000, _ E.L. DISEASE-- POLICY LIMIT S 1,000,0 rem blia—i .. - DESCRIPTION OF OPERATIO a 101. AdaM-1 N—H,w S*Wddn, n—.q._ 1-"I" COPTICIRATO Yn1 nca _ MAMIS2 - -- - SHOULD ANY OF THE AMWE D220PJBM E'OLIIMMS BE CANCELLED BEFORE Village of Miami Shores THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 10050 NE 2 Avo. ACCORDANCE WTN THE POLICY PROVISIow Miami Shores, FL 33138 AUTHOORRRM0 RRMMMNTAT04 01OW2010 ACORD CORPORATION. All rights reserved. --•-- F� Rte•' •..,..:,r 1 no AuuKu name and logo are registered marks of ACORD BUILDERS 1 FiRS%CLASS UA. pro STAGE WAIA FL PERKY NO. 231 5955233=' THIS IS1N0TABU. —DO NOT PAY RENEWAL BU�►sl999TENERS INC STATEM1907818 621250-a 7 005 N wA rERwAY DR, 304 33155 LININ DADE COUNTY QWM%DSTONE BUILDERS INC IMM BUILDING CONTRACTOR WORKEI/S OKW- Aa D TO VIQLATE Atar ' �� � DO NOT FORWARD o¢a rAWOMW LANOSTONE BUILDERS INC Wwo `aLICBM VICENTE CAMMARANO 7005 N WATFRWAY DR 304 MIAMI FL 33155 �C0UN'iY TATE '07/31/2012 60030000289 000075.00 SEE OTKER SSE PAGE 01/06 iami Shores village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 SWIMMING POOL OWNER'S CERTIFICATION _ate. I f. 2a. ?� 1 Miami Shores Village Building & Zoning Department Attention: Building Official I certify that I am the legal owner of the property described as Yaw y1jakhL 1C t o Q � , located at 101® UE In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. I further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the E.. r� Legal Owner Note: This certification is to be submitted with a swimming pool permit application in duplicate. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE KNOW ALL MEN BY THESEPR SENTS: WHEREAS, the undersigned is/are the fee simple owner(s) of the following described property situated and being in Miami Shores Village, Florid Address: A LQ 9 Q W L I Q J r l pry S Whereas, the undersigned owner(o 1 t r desire to to utilize said Lot(s) as a single building site, and the undersigned owner(s) do(es) hereby declare and agree as follows: I. That the property will not be used in violation of any ordinances of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. II. That the purpose of the covenant is to induce Miami Shores Village to issue a permit for a pool where the required enclosure is not on the subject property where the pool is located. III. That if any of our adjoining neighbors remove any portion of their fence or wall, or if our/my property shall fail to meet code requirements for pool barriers, we, as owners will immediately install a protective enclosure to meet code requirements and will obtain a permit for such fence. IV. That, I/we, as owner(s) hold Miami Shores Village harmless for any negligence or injury that results from not having the enclosure. V. If enclosure belongs to said property, I agree to maintain & or replace said enclosure in the event that is damaged or removed by any case. NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the above property and shall constitute a covenant running with the land and shall be binding upon the undersigned, his/her successors and assigns and may only be released by Miami Shores Village, or its successors, in accordance of said Village then in effect. '**0W SIGN & '''RI OWNER SING & PRINT I He�eb-y Certify that on this day personally appeared before me V�''�K'i S r4- and has produced ID #_n CeM1S'L' as identification and he/she acknowledge that he/she executed the foregoing, freely and voluntarily, for purposes there in expressed. SWORN TO AND SUBSCRIBED before me on this 01� day of r!1 ' 20 2 NOTAR UBLIC STATE F IDA (Revised 0512209 LJ;df Notary Public State of Florida Clarissa EganeMy Commission DDS40881Expires 1 1 /1 812 01 3 TIVE 'Ell, (0s --ji-.7 O NOV 302 1d�o u ar., OPERATING INSTRUCTIONS MANUAL "MEETS REQUIREMENTS,'6F ASTM SAFETY C',1F1MT,10 1 F 2208" This product has been designed !to aid in the detection of unwanted intrusions into unsupervised pools. POOLGUARD IS A SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE. "This device ,is not intended to replace any other safety consideration - i.e., adult supervision, lifeguards, fences, gates, pool covers, locks, etc., and some devices may not detect gradual entry." r GENERAL POOLGUARD is the result of quality design and manufacturing techniques that are a standard at PBM Industries, Inc.; a company dedicated to high quality products. POOLGUARD is a result of that dedication and we guarantee and stand behind the POOLGUARD alarm system. POOLGUARD Pool Alarms have been tested and comply to the ASTM Safety and Performance Standard for Pool Alarms, ASTM F 2208, see insert. POOLGUARD is an electronic monitoring system that automatically sounds an alarm when children or pets fall into your unsupervised pool. POOLGUARD is a portable, self-contained, lightweight unit that is safe and simple to operate. Entry into the pool will be detected by the unit's electronic sensor, triggering a loud pulsating alarm and an internal RF transmitter. The remote receiver will receive the transmitted signal and sound an alarm within the home. INSPECTION POOLGUARD is packaged in a shipping carton that minimizes the chance of damage due to handling. Check for damage and confirm that the con- tents of the carton include the following items: • POOLGUARD Unit • Handle • Remote Receiver and Power Supply • Operating Instructions Manual • Warranty and Registration Card If an item is missing, contact either the place of purchase or. PBM Industries, Inc. for replacement. CARE AND HANDLING POOLGUARD is constructed from sturdy plastic to withstand the adverse moisture environment of a swimming pool. Care needs to be taken when handling to ensure against being dropped, kicked, etc. Also, be sure to remove the pool unit and set it away from activity in the upright position when the pool is being used, (See Figure 1). If the pool unit accidentally falls into your pool, remove it immediately and drain the water from it. Take the unit apart as indicated in the Battery Replacement Procedure and remove the battery. Tip and shake unit and remove all excess water from inside the unit and the battery, and the circuit board area with a paper towel or cloth. Completely test unit before each use as described in manual to ensure proper operation. (Remember to always remove the pool unit from the pool while swimming and set it aside away from pool activity). r - ATTACHING HANDLE The two handle screws are located in the top of the alarm, remove them and attach the handle, (See Figure 1). INSTALLING YOUR ALARM RESET/SLEEP SWITCH (SEE FIGURE 1) RESET: When the pool unit is installed in the pool and the horn is sounding; press the reset/sleep switch once to silence the alarm. SLEEP MODE: When the pool unit is removed from the pool and the horn is sounding; press and hold the reset/sleep switch for 3 seconds to silence the alarm. The pool unit will automatically wake up when it is installed into the pool. THE POOL UNIT WILL NOT GO INTO SLEEP MODE ONCE IT IS INSTALLED IN THE POOL! SILENT INSTALLATION AND REMOVAL FEATURE • The poolguard system will sound an alarm (Horn will sound) when you install or remove the pool unit from your pool. If you would like the poolguard system not to sound an alarm (horn will not sound) when you install or remove the pool unit from your pool, follow the directions below. 1.SILENT INSTALLATION (HORN WILL NOT SOUND) • Press and hold the reset/sleep switch for 3 seconds, until you hear the pool units horn chirp. Release the reset/sleep switch, you now have 15 seconds to gently and slowly install the pool unit into your pool without the horn sounding. POOLGUARD WILL INSTANTLY BE MONITORING YOUR POOL FOR AN INTRUSION. 2. SILENT REMOVAL (HORN WILL NOT SOUND) • Before removing the pool unit from your pool. Press and hold the reset/sleep switch for 3 seconds, until you hear the pool units horn chirp. Release the reset/sleep switch, you now have 5 seconds to remove the pool unit from your pool without the horn sounding. IMPORTANT: THIS DOES NOT TURN POOLGUARD OFF, IF THE POOL UNIT IS NOT REMOVED IT WILL CONTINUE TO MONITOR YOUR POOL FOR AN INTRUSION. (Cont. on next page) P SILENT INSTALLATION AND REMOVAL FEATURE (Cont. 3. POOLGUARD HAS DESIGNED THIS FEATURE FOR "ONLY" THOSE WHO HAVE THE RESPONSIBILITY OF INSTALLING OR REMOVING THE ALARM FROM YOUR POOL! BATTERY INSTALLATION / REPLACEMENT (Battery not included) POOLGUARD is powered by a standard 9 -volt alkaline battery. To install or replace the battery: • Remove the screw from the bottom of the unit, (See Figure 1). • Carefully slide out electronics assembly; do not pull or jerk on internal hook up cable. (If necessary, gently shake unit to remove assembly.) • Remove old battery and check for leakage or corrosion. (Remove any leakage or corrosion if present before installing new battery.) • IMPORTANT: WHEN A 9V BATTERY IS FIRST INSTALLED IN THE POOL UNIT, THE HORN WILL SOUND. TO SILENCE THE ALARM PRESS AND HOLD THE RESET/SLEEP SWITCH FOR 3 SECONDS. THIS PLACES THE POOL UNIT IN SLEEP MODE. THE POOL UNIT WILL AUTOMATICALLY WAKE UP WHEN IT IS INSTALLED INTO THE POOL. •Install new battery by attaching snap connection and sliding into battery holder. • Slide electronics assembly into pool unit; do not pinch internal hookup cable. • Replace the screw, hand tighten until screw is all the way in and flush against the pool unit. To prevent possible damage, battery should be removed whenever storing the alarm, for an extended period of time. LOW BATTERY FUNCTION The POOL UNIT AND THE REMOTE RECEIVER will beep once approximately every 20 seconds to alert you that the battery is low in the pool unit and needs to be replaced. A e HANDLE SCREWS ELECTRONICS ASSEMBLY �"• GASP` �� HORN 85d6 at 10 feet INTERNAL SCREW BATTERY HOOKUP RESET/SLEEP HOLDER CABLE SWITCH PLACEMENT IN YOUR POOL POOL UNIT FIGURE 1 UPRIGHT POSITION Figure 2 illustrates locations best suited for detecting intrusions from any area of the pool. If your poo[ °is larger than 800 square feet, if you have more than 2 return lines, any concerns about the size, or if you have an irregular shaped pool or water features such as waterfalls, please call customer service to clarify the recommended number of alarms and locations for alarms: 1-800-242-7163. Poolguard Pool Alarms have been tested and comply to the ASTM Standard Specifications for Pool Alarms ASTM F 2208, in a 16'x 32' pool. POOLGUARD alarms can be used in pools up to 20' x 40' or 800 square feet. FIGURE 2 Pools 800 Square Feet and Smaller. (Cont. on next page) r PLACEMENT IN YOUR POOL (Continued) POOLGUARD automatically compensates for variations in pool levels within the unit's operating range. The unit utilizes a sensing throat which projects into the water and is designed to operate in most pools with an in -wall skimmer. The sensing.throat cannot be less than 2 inches, (See Figure 3), and not more than 7 inches into the water, POOLGUARD recommends that the sensing throat be approximately 4" in the water POOLGUARD can be used with SOLAR BLANKETS on the pool. POOLGUARD can also be used in spas. SENSING THROAT CANNOT BE LESS THAN 2" IN THE WATER, POOLGUARD RECOMMENDS THAT THE SENSING THROAT BE APPROXIMATELY 4" IN — THE WATER IMPORTANT FIGURE 3 POOLGUARD may not function properly if your pools water level is not maintained within the required levels of your alarm. Also, the unit may not operate effectively while certain types of automatic pool cleaners are in operation. Some irregular shaped decks may not provide a level foundation for the unit by the pool's edge. This minor problem can be overcome by appropriately supporting the unit, (See Figure 3). STABILIZING YOUR POOL ALARM The Alarm Stabilizing Pin (ASP) is factory installed onto your pool alarm. Tools needed to install your alarm are: One 5/16" masonry drill bit that can be found at your local hardware store, a drill, a pencil, a tape measure or yard stick. 1. Position your pool alarm so that the sensing throat is in the water and the ASP is touching the deck, (leave a small space no more than 3/8" between the sensing throat and the top edge of your deck or coping), (See Figure 4). 2. Mark with a pencil the spot where you wish to drill the hole for the ASP. 3. With the 5/16" masonry drill bit, drill a hole 2 1/4" inches deep, as straight as possible. (Cont. on next page) v r STABILIZING YOUR POOL ALARM (Continued) 4. Clean off the debris and install the alarm by placing the ASP into the 5/16" diameter by 2 1/4" deep hole. 5. Your Pool Alarm is now ready for use. If you have any questions or need help with installation, please give us a call at 1-800-242-7163. 6. Be sure to keep your ASP hole clean from debris and dirt so that your alarm will always lay flat on the pool deck when installed. REMEMBER THAT THE POOL UNIT MUST BE REMOVED FROM POOL BEFORE SWIMMING! ALARMS STABILIZING 2 1/4" SMALL SPACE, NO MORE SENSING THAN 3/8" WATER LEVEL MARK LOCATION FOR 5/16" DIAMETER & 2 1/4" DEEP HOLE IN DECK POOL DECK FIGURE 4 Sensing throat cannot be less than 2" in the water, P001 -GUARD recommends that the sensing throat be approximately 4" in the water. TEST BEFORE USING To ensure effectiveness, test POOLGUARD every time you place it into the pool by performing the following procedure: •POOLGUARD DOES NOT HAVE AN ON/OFF SWITCH When the alarm is in the pool it is always in the ON position and cannot be turned off. When the alarm is out of the pool it is always in the OFF position. *To test your alarm push an object of appropriate volume and weight off the deck edge at the farthest location from the alarm. (A four (4) gallon jug of water or 3 -one (1) gallon jugs of water tied together are ideal for testing.) The alarm should sound when the water action caused by the intrusion reaches the unit. It may take a few seconds for the alarm to react to the water action. (Cont. on next page) TEST BEFORE USING (continued) *After resetting the alarm and allowing time for the water action to settle, repeat the procedure from another point in the pool until you are confident of detection performance. •POOLGUARD includes a timer function which automatically resets the unit after the alarm has sounded for approximately 5 minutes. ADJUSTING YOUR RETURN LINE FITTINGS The P001 -GUARD alarm should not be placed too close to a return line, also do not place P001 -GUARD in a location in the pool where a return line is pointing in the alarms direction. Water turbulence may be too strong, falsely setting the alarm off or the water turbulence may interfere with the alarms ability to detect an intrusion. If you have more than 2 return lines please call customer service at 1-800-242-7163. It is very important in pools to adjust all the eyeball fittings on your return lines so that the water flow will not interfere with your pool alarm. Point all the eyeball fittings down and your pool will still circulate properly and this will allow POOLGUARD to function properly, (See Fgure 5). Pointing the eyeball fittings down also helps prevent algae growth. CORRECT INCORRECT FIGURE 5 POOLGUARD REMOTE RECEIVER The POOLGUARD REMOTE RECEIVER has been integrated with the standard POOLGUARD unit to provide a wireless remote alert operating at distances of up to 200 feet. The POOLGUARD REMOTE RECEIVER sounds an alarm in the house when the POOLGUARD unit is activated at the pool.The remote system consists of the following functional elements: • A coded pulse receiver (Remote Receiver), (See Figure 6). • A standard wall outlet power supply, (See Figure 6). The REMOTE RECEIVER is a compact unit powered by a UL and CSA approved AC/DC power supply. The REMOTE RECEIVER can be placed on a table or a counter top inside the house. The pulse coded radio frequency signal is transmitted from the pool unit and is received and decoded to sound the remote receiver. The remote receiver will sound for an additional 3 seconds after the pool unit has been silenced. If the REMOTE RECEIVER beeps once approximately every 20 seconds, it is indicating that the 9v battery in the pool unit is low and needs to be replaced. After you have purchased your POOLGUARD alarm and you wish to add another remote receiver to your alarm system you can acquire one from PBM Industries, Inca Contact PBM by phone or mail or contact your place of purchase. POWER SUPPLY FIGURE 6 B Horn at 10 feet MOTE RECEIVER TO OPERATE YOUR REMOTE RECEIVER Try to locate your REMOTE RECEIVER in a convenient part of your house close to the pool. Avoid steel walls or any other large metal objects or obstructions that might interfere with the signal reception. The REMOTE RECEIVER has to be placed on the same level or a level above the pool in the house (do not place receiver in an underground basement). The ideal location for your REMOTE RECEIVER would be by a window overlooking your pool. Test your REMOTE RECEIVER in different locations in your house to find the best working place for your receiver. Connect the power supply to any 120V, electrical outlet and insert the jack into the receiver. Check that indicator light is on. Your REMOTE RECEIVER unit is now ready to receive a transmission from your POOLGUARD unit. DO NOT USE YOUR REMOTE RECEIVER OUTDOORS. e1 W i SWIMMING POOL SAFETY TIPS • Supervise children at all times. • Never permit swimming alone. Never leave a child alone, even to answer the telephone. • Always remove the entire solar cover from a pool before swimming. • Remember that alcohol and water safety do not mix. • Have your pool area fenced and the gate locked to prevent unauthorized entry to the pool, and install a gate alarm. •Lock and secure all doors in the house which permit easy access to the pool, and install a door alarm. • Have a responsible adult teach swimming and water safety to your children. • Maintain clean, clear water in the pool. • Do not swim during electrical storms. • Do not permit bottles, glass, or sharp objects to be used around the pool. • Ask your pool dealer how you can improve your pool safety — they will be glad to assist you. • Above all: remember that common sense, awareness, and caution will allow you to enjoy your pool. WARRANTY AND REPAIRS P001 -GUARD is sold with a limited warranty to cover defects in parts and workmanship for three years from date of purchase, (retain proof of purchase). If P001 -GUARD exhibits a defect, please call Customer Service. at 1-800-242-7163. Unauthorized returns will not be accepted. Proper repair is only ensured when the unit is returned to the manufacturer. SEND CORRESPONDENCE TO: PBM INDUSTRIES, INC. P.O.BOX 658, NORTH VERNON, IN 47265 1-800-242-7163 This product has been designed to aid in the detection of unwanted intrusions into unsupervised pools. POOLGLIARD IS A SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE."This device is not intended to replace any other safety consideration-'i.e., adult supervision, lifeguards, fences, gates, pool covers, locks, etc., and some devices may not detect gradual entry" Poolguard t"rea ASTM CF� 11PSP 2208 PBM INDUSTRIES, INC. , 8spRoti%"�_ w- E REV. 10/2007 Power Suooly ooiguard Poolside Unit FALSEALARMS Remote Receiver All pool alarms will false alarm on occasion for different reasons. False alarms can be minimized; however, it is important to remember that a false alarm is better than no alarm at all. WEATHER & WIND—POOLGUARD sets stationary on the deck of the pool so the wind will not effect the alarm unit itself. Wind may trigger a false alarm if it is strong enough or steady enough that it causes the water in the pool to rock or bounce up and down the pool wall. When the water in the pool moves up and down the POOLGUARD sensing throat, it may finally cause the alarm to sound. On extremely windy days when the pool water is rocking it is advised to remove the POOLGUARD from the pool. Light wind or rain will not effect the POOLGUARD alarm. Another false alarm occurs when the pool owner tries to install the alarm too soon after swimming. After swimming, the water in the pool will rock or bounce up and down the pool wall for some time depending on the size of the pool and the type of swimming activity. Before installing the alarm, after swimming, the pool must be given time to calm. Time will vary (around 10 to 30 minutes); once the pool owner sees that the pool water is no longer rocking up and down the pool wall, it is time to install the alarm. Certain automatic cleaners may set the POOLGUARD unit off in some cases. If the cleaner head, or the cleaner hose hits the POOLGUARD alarm it may cause it to false alarm. Solutions to this problem are to use your cleaner at night and your alarm during the day. Another option would be to find a. place around the pool where the cleaner does not interfere with the alarm. Certain water features such as waterfalls can cause POOLGUARD to false alarm. To avoid this problem do not install the POOLGUARD alarm too close to the water feature. If you are having a problem with any type of water feature call POOLGUARD at 1-800-242-7163. ALARM PLACEMENT The alarm should be on a flat, solid surface for best results. The throat of the unit is designed to work in most pools with an in -wall skimmer. The water level up on the throat is important and should be checked. The sensing throat cannot be less than 2 inches in the water, and not more than 7 inches into the water. POOLGUARD recommends that the sensing throat be approximately 4 inches in the water. POOLGUARD can be used with a solar cover; however, before removing the cover, the alarm should be taken out so it does not get pulled into the pool. ALARM TESTING Drop something of approximate size, weight and volume of the families smallest child, the farthest paint away from the alarm. A four (4) gallon jug of water or 3 one (1) gallon jugs of water tied together are ideal for testing. Remember, when testing you must wait about 15 minutes between tests for the pool to calm. ALARM WILL NOT SOUND Be sure that a 9 volt battery has been installed properly. If you are testing and POOLGUARD does not alarm, be sure you are testing properly — putting your feet in the pool, splashing with your hands, making waves with a leaf skimmer, or dropping something into the pool that does not have the proper size, weight and volume will not set the POOLGUARD alarm off! Testing is very important and should be done correctly. CARE AND HANDLING POOLGUARD is made of sturdy, rigid vinyl PVC - UV rated. Because the alarm is electronic and mechanical great care should be taken not to drop the unit; like any other appliance, it may break. Sun and rain will not hurt the alarm. POOLGUARD is water resistant but not waterproof. Great care should be taken not to knock',the alarm into the pool. If the alarm goes into the pool there are directions in the manual on how to dry it out, but more than likely it will have to be returned to the factory for service. Always remember to remove the alarm before using the pool. REMOTE RECEIVER When the unit at the pool alarms, the remote receiver will sound. Maximum Range for the remote is 200 feet from the poolside unit. Avoid placing remote in, basements or close to metal walls. Be sure that the red light on the remote is on. Remember the poolside unit must be beeping (alarming) for the remote to work. If your remote receiver is not;getting a clear signal or no signal from the poolside unit, try the following: Before plugging in the power uppi sure to stretch out the cord; do not leave it tied in ,ebe d. When you first plug in the remote it will give one short loud beep then stop. Your Remote Receiver is similar to a small portable radio. If your remote is not sounding when the poolside unit is sounding—move the remote to different locations and stand back for a few seconds for the remote to pick up the signal. You may only have to move your remote a little to the left or right to bring in the signal—in some cases you might have to move the remote to a different location or another room. If you cannot get a signal on your remote receiver CALL CUSTOMER SERVICE AT 1-800-242-7163 W • DO read the manual carefully • DO install a 9 volt battery • DO untie the bow on the power supply • DO test the alarm properly • DO carry your alarm by the handle • DO remove alarm before swimming • DO hold on to your red customer service card with our 800 service number • DON'T leave alarm in pool while swimming • DON'T drop your alarm, it may break • DON'T knock or let your alarm fall into the pool • DON'T install your alarm immediately after swimming • DON'T use your alarm on extremely windy days `Ai!we:l anoA 1381OJd sdiaH sj3npoJd ;o /(HWBA s,p.ienBlOOd WHV1V 31VO 310W38 HDIA INHV-IV 100d ®Nnobi!D 3n08V 31OW38 HIM INEW IV IOOd aNnod!D NI 0 �Wsozz � lsb) wise T96< as ipvw "VA miovmq�, DIUdA3xAS-loH (1009 «NOLUTIOs ISHU,> s)fxzt IV ""d Q?tViKj OOd ANN't PO DAPT-2 Manual 122208:Layout 1 5/14/09 12:42 PM Page 1 —+- I L 5. • • When the 9 -von battery Is low, the door alarm horn Will chirp once every 10 seconds -this means It to time to install a new battery, Battery life Is approximately 1 year. Teat your door alarm weekly by opening the door and allowing the alarm to sound. POOLGUARD Is sold with a limited warranty to cover defects In perp and workmanship for one year from date of purchase. (Retain proof of purchase). If Pooiguard exhibits a defect, please call our Customer Service department at 1.800.242-7163. Unauthorized returns will not be accepted. Proper repair is only ensured when the unit Is returned to the manufacturer. Visit our website at www.pooiguard,com to fill out your warranty registration Information. PBM INDUSTRIES, INC. P.O. Box 655 NORTH VERNON, IN 47265 812-346.2845 �oolguard• PBM INDUSTRIES, INC. MADE IN THE USA REV. 5.09 .- -Supervise children at all times. •Never permit swimming alone. Never Nave a child alone, even to answer the telephone. -Always remove the entire solar cover from a pool before swimming. • Remember that alcohol and water safety do not mix. -Have your pool area fenced and the gate lockatl to prevent unauthorized entry to the pool, and Install a gate alarm. -Lock and secure all doors in the house which permit easy access to the pool, and Install a door alarm. -Have arespon your childrenel6le adultteach swimming and water safety to -Maintain clean, dear water In the pool. • Do not swim during electrical storms. -Do not permit bottles, glass, or sharp objects to be used around the pool. •Ask your pool dealer how you can Improve your pool safety—they will be glad to assist you. -Above all: remember that common sense, awareness, and caution will allow you to enjoy your pool. poolguard' ii .• www.poolquard.com INSTALLATION OF OPTIONAL SCREEN DOOR KIT DOORALARM CONNECTING DOOR ALARM TO SENSOR SWITCHES READ THE DOOR ALARM MANUAL FOR INSTALLATION ON ONE DOOR FIRST:InstallationInstructions THE SENSOR WIRES ARE PERMANENTLY CONNECTED TO THE DOOR ALARM, CONNECT BOTH SENSOR WIRES COMING FROM THE DOOR ALARM MODEL DAPT-2 TO THE SENSOR SWITCH ON THE DOOR FRAME. THEN USE THE SUPPLIED MEETS UL 2017 SIeNAM JUMPER WIRES TO CONNECT TO THE SCREEN DOOR SENSOR SWITCH (SEE DIAGRAM BELOW). THE TWO SENSORS SHOULD BE HOOKED UP IN _ _ PARELLEL WITH EACH OTHER. • THE PLASTIC COVERS ON THE SENSOR SWITCHES 8 SENSOR MAGNET MUST BE REMOVED BEFORE INSTALLATION • SWITCHES GO ON THE FRAME BY THE DOOR I T SENSOR 000n MAIIM LISTED SWITCH • MAGNETS GO ON THE DOOR ITSELF - SEE PICTURE IN MANUAL EQUIPMENT NEEDED A. ONE DOOR ALARM AND 2 MOUNTING SCREWS \ B. ONE SET OF SENSOR SWITCH AND SENSOR MAGNET AND 4 SCREWS+ FOR DOOR FRAME a DOOR I \ \ • swirte°U C. ONE SET OF SENSOR SWITCH AND SENSOR MAGNET, JUMPER WIRES, AND 4 SCREWS \ Nosa - FOR SCREEN DOOR FRAME AND SCREEN DOOR \ IF YOU HAVE ANY QUESTIONS CALL US AT 1.800.242.7165 MAIN DOOR SCREEN DOOR xNeac season aMAIM ? wgEs swrtcH sWON DOOR ALARM Figure 1 0 a i9a»a The horn is 85dB at 10 feet c LED ® PASSTHRU • • RTANT • SWITCHREAD THOROUGHLY BEFORE O O ® The product has been designed to aid in the detection of unwanted JUMPER,,,XORN intrusions into unsupervised areas. POOLGUARD DAPT-2 ISA WIRES SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE. It should be used in conjunction with the safety equipment currently in use Figure 5 SENSG, INand should not affect existing safety procedures. l Ir 01 PG DAPT•2 Manual 122208:Layout 1 5/14/09 12:42 PM Page 2 INSTALLING THE 9V BATTERY4 11� 21 A. Remove the assembly screw from the back of the door alarm and remove the top cover. (See Figure 2) B. Pull down the battery spring and install the 9v battery (see figure 2). NOTE: If the battery spring is not in the correct position under the battery, the alarm will not go back together. C. When the 9v battery Is Installed, the LED will flash once every 10 seconds. When the alarm sounds, the LED will flash once every second. D. Reassemble the door alarm with the assembly screw. NOTE: Once the battery is installed the alarm may sound accidentally until the sensors are connected property. Your Poolguard Door Alarm Is designed to be installed Within 22" of the sensor switch for the sensor wire connection. To mount the door alarm on wall next to door: alnTEAY3pNWG. ! eATTEPY Figure 2 j HAN4[RNMB r"i�'�t;�i� ASSBMa1Y Knew Ha.e +NANGEe NIkF A. Determine the best location. The door alarm must be Installed at least 64" above the threshold of the door. B. With a pencil, mark 2 spots 2 1/2" span vertically (up a down) where the alarm will be mounted. These 2 marks are where the 2 larger supplied screws will be inserted Into the wall to hang the door alarm. C. Insert the 2larger supplied screws Into the wall on the 2 marks, Leave about 5/32" (not Including the head of the screw) of the screw from the wall. D. Hang the door alarm on the mounted screws and pull downward until the screws are positioned In the small end of the hanger holes In the back of the alarm. E. If you purchased the OPTIONAL Screen Door KIt see section 6. (Figure 5) 3. INSTALLING 1e1' SENSOR A. The Door Alarm comes with one sensor switch and one sensor magnet; remove the covers from both of these parts by using your fingernail or small tool to unclip the cover from the bottom side and sliding it off the sensor. B. Each sensor has two holes for mounting, the sensor magnet usually goes on the door and the sensor switch is usually mounted to the door frame. C. Metal framed doors may need a space between the sensors and the door using a small piece of wood or double sided foam tape. D. The Sensors must be Installed parallel to each other with a spacing between them of approximately W4. The sensors can be mounted HorLmrhally or Vertically as long as they remain parallel E. Loosen the two terminals on the sensor switch by loosening the spews then place either wire end caning from the door alarm between each of the terminals. It doesn't matter which wire goes to which terminal, Replace Plastic Covers. Note: If the cover for the sensor switch does not lock into place because of the sensor wires, remove the knockout from the side of the sensor switch cover (See Figure 4) "1i si The POOLGUARD DOOR ALARM uses two delay modes which allow the user to exit and enter the door without the alarm sounding. These two modes are explained below. A. FIRST DELAY MODE: When the door Is opened the alarm automatically goes Into the first delay mode which gives you 7 seconds after the door Is opened to push the pass thru switch. If the pass thru switch Is not pushed within 7 seconds the alarm Will sound with the door open or closed. To silence the alarm close the door then push the pass thru switch. B. SECOND DELAY MODE: When the door Is opened and the pass thru switch is pushed within 7 seconds, this puts the door alarm in the second delay mode which allows you 14 seconds to go through the door and close It. When the door is closed within 14 seconds, the alarm will automatically reset. If the door Is not dosed. within 14 seconds, the alarm will sound. Figure 4 SENSOR ITCH PLASTIC COVER SW O aNOCNOU x�. �—TERMINALS IL ooMguard' F n . 16AT �R%4x DATE ALARM aro Fanply ly oof f Products Helps Prolct Your Familyl www.pooiguard.com ABOVE GROUND POOL ALARM WITH REMOTE RECEIVER IN ARM REM ERECEOOL WITH REMOTE RECEIVER WITH n . 16AT �R%4x DATE ALARM aro Fanply ly oof f Products Helps Prolct Your Familyl www.pooiguard.com U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE Federal Emergency Management Agency OMB No. 1660-0008 National Flood Insurance Program Expires March 31, 2012 s Important: Read the instructions on pages 1-9. SECTION A - PROPERTY INFORMATION Al. Building Owner's Name VICENTE CAMMARANO A2.Buikiing Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 1080 NE 105' STREETOik City MIAMI SHORES State FL ZIP Code 33138 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 9, BLOCK 1, PLAT BOOK 47, PG 58, PUBLIC RECORDS OF MIAMI DADE COUNTY, FL A4.Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A5.Latitude/Longitude: Lat. 25"52'18.48 Long. 80"10'31.79 Horizontal Datum: El NAD 1927 ®NAD 1983 A6.Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. ATBuilding Diagram Number 8 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an'attached garage: a) Square footage of crawlspace or enclosure(s) 2100 sq It a) Square footage of attached garage 200 sq It b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage enclosure(s) within 1.0 foot above adjacent grade 7 within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b 504 sq in c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes ® No d) Engineered flood openings? ❑ Yes ® No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number 62. County Name B3. State MIAMI SHORES 120652 MIAMI DADE FL B4. Map/Panel # B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) 12086CO306L L Date Effective/Revised Date Zone(s) (Zone AO, use base flood depth) 09-11-09 09-11-09 AE 8 FT B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe) N/A B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) N/A B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date N/A ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ® Building Under Construction* [I Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, ARAE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item AT Use the same datum as the BFE: Benchmark Utilized MDCBMVertical Datum NGVD 29 Conversion/Comments N/A Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 5.52 ® feet ❑ meters (Puerto Rico only) b) Top of the next higher floor 8.25 ® feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) N/A. ❑ feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) 5.22 ® feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building NN/A. ❑ feet ❑ meters (Puerto Rico only) (Describe type of equipment and location in Comments) 0 Lowest adjacent (finished) grade next to building (LAG) 5.06 ® feet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade next to building (HAG) 5.20 ® feet ❑ meters (Puerto Rico only) h) Lowest adjacent grade at lowest elevation of deck or stairs, including 6.28 ® feet ❑ meters (Puerto Rico only) structural support SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information: I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be un' hable by fine or imprisonment under 18 U.S. Code, Section 1001. ®Check here if comments are provided on back of form. Wer atitu and lo gitude in Section a provided by a licensed land surveyor? ❑ Yes ❑ No 1. Certifier's N me JOH I RRA License Number 5204 Title PR (DENT Company Name JOHN IBARRA & ASSOCIATES, INC. _� r Address 77 IN 72 A 3 25 City MIAMI State FL ZIP Code 33126 P I#5204 Signature Date 07/27/2012 Telephone 305-262-0400 \! 07/27/2012 'EMA Form 81-31, Mar 09 See reverse side for continuation. Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding Information from Section A. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No) or P.O. Route and Box No. 1080 NE 105TH STREET City MIAMI SHORESState FL ZIP Code 33138 SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agenticompany, and (3) building owner. Comments C.O.R. = 3.68 FI; LATITUDE AND LONGITUDE DETERMINED BY SURVEYOR USING GOGGLE EARTH; MIAMI DADE COUNTY BENCH MARK # B -26 -RD LOCATOR NO. 3250; ELEVATN = 17.24 FT OF N.G.V.D 1929 Signature Date 07/27/2012 ❑ Check her jf attach SECTION E - ElUILDING EL INFORMATION (SURVEY NOTREQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), mplete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1 -E4, use natural ade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ® above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided'in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet 0 meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet '0 meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, 8, and E are correct to the besYof my knowledge. Property Owner's or Owner's Authorized Representative's Name VICENTE CAMMARANO Address 1080 NE 105TH STREET City MIAMI SHORES state FL ZIP Code 33138 Signature Date 07/27/2012 Telephone Comments ❑ Check here ffattachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4 -G9) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued 37. This permit has been issued for: ® New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building; ' ❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum G10. Community's design flood elevation ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature - Date 07/27/2012 Comments FEMA Form 81-31, Mar 09 Replaces all previous editions 2 Building Photographs See Instructions for Item A6. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 1080 NE 105TH STREET City MIAMI SHORES State FL ZIP Code 33138 For insurance Company Use: Policy Number Company NAIL Number If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View'; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. FRONT VIEW 07/27/2012 KtAK VltW 07/27/2012 I Building Photographs Continuation Page For Insurance Company use: Building Street Address (induding Apt., Ur* Suite, and/or Bldg. No.) or P.O. Rode and Box No. Policy Number 1080 NE 105TH STREET City MIAMI SHORES State FL ZIP Code 33138 Company NA1C Number I• igmore phottr oepreg page, affix the additional photographs below. dentify all photographs fdiey hog"Rear /n ; ifrequired, YRVM Side # and tlLelt-SM*ww.* LEFT VIEW 07/27/2012 RIGHT VIEW 07/27/2012 THE FUBLIC RECORDS OF MIAMI-DADt COUNTY, FLORIDA. LOCATION SKETCH NOT TO SCALE � a I r` NE 10T1hst Rh St° M. ,o - �+ iI rl g gg f5� r° sa a. WmlSAores CmaltryCNA - l 3f ! A = ARC. A.C.= AIR COWITZWSR PAD. A.E.=ANCHOR EASEMENT. .. A.R.= ALUN3NOM ROOF. A.S.= ALUMINM SAW. ASPH.= ASPHALT. D. C..= BLOCK CORMm. BLDG.= BUILDING. D. M. BENCH MANE. B.C.R.= BROURM COUNTY RECORDS. B.O.B.= BASIS OF BEARINGS. (C) = CALCULATED. C.B.= CATCH BASIN. C.B.S.= CITE BLOCK STRUCTURE. C.B.W.= CONCRETE BLOCK HALL. CH= CHORD. CH. B.= CHORD BLARING. CL.= CTRAR. C.L. F. = CHAIN LadC PENCE. C.M.E= CANAL MMUMMA= AmSEMENTS. CONC.= COIR30 lE. C.U.P. = CONC. UTILITY POLL C.P.= COWC. PORCH. C.S.= CONCRETE SLAB. C.W.= CONCRETE AALK. D.S.= DRAZNUM EASEMENT. D.M.E.= DRAZAAM MAINTZRANCE EASEMENTS. DRIVE = DJUVERar. ° = DTEGRQS. EB:= aLECTRIC BOX E.T.P.= ELECTRIC TRANSYIORIMLR PAD. ELEV. = SZEmrIpN. ENCR.= EMCROACHMMINT F. H. = FIRE HYLEANT. F.Z.P.= POUND ZACK PIPE. F.I.R.= FOUND IBM ROD F.F.E.= FINISHED FLOOR ELEVATZCN. F.N.D.= FOUND HAZE i. DISK. FT.= FEET. R92P.= FEDERAL NATIONAL INSURANCE PROGIANI. F. N. = FOUND ARIL. R.= HIGH (HEIGHT) IN. AEG.= INGRESS AND EGRESS EASEMENT. L.B.= Certificate of Authorisation L.B./7806 L.P.= LIGHT POLL. L.F.E.= LOWEST FLOOR ELEVATION. L.M.E.= LAKE lGl EASEMENT. ' = NINUMS. (M)= )WASURW DISTANCE. ABBREVIATION AND MEANING Js = bwL BOX . M.D'.C.R.= HIAIff DAM COUNTY REOCRDS M.E.= JQZNT&NMM E�ffiiT M.N.= HALNAOLE. N.A.P.= NOT A PART OF. HGVD - NATIONAL GEODETIC VERTICAL DATUM. H.T.S.= NOT TO SCALE. /-NO. = HLlNBER. O/S =. OPFSET. O. H. = OVJ30 AD O.H.L.= OVERHEAD UTILITY LINES. O.R.B.= OFFICIAL RECORDS BOCK. - O.V.H.= OVERHANG. PVMT.= FAVJMdD?r. PL.= PLANTER. F/L - PROPERTY LINE. P.C.C.= POINT OP COs'OOND CURVE. P.C.= POINT OF CURVE. PT. = POINT OF TANf ". POC.= POINT OF c0sla CEdwr. P.O.B.= POINT OF BEGZRWING. P.R.C.= POINT OF REVERSE CURVE. PYY = PARKWAY. PER = PER)QKl'NT REPERENZ N7NlvNT. F.L.S.= PROMSIONAL LAW SURVEYOR. P.P.= FOUR POLE P.F.S.= POOL PUIV SLAB P.U.H.= PUBLIC UTILITY EAS012117 (R)= RECORD DISTAMRE. RR.= RAIL ROAD. RES.= RESIZIDR$. R/W= RIGHT-OF-WAY. PAD .= RADIUS CIR RADIAL. RGX.= RANGF. R.O.E.= ROOF OVERHANG RASEN=7. .SEC.= SLCTIOW. STY.= STORY. SWWiK. = SI!>B.7UILTC. S.Z.P.= SET ZROH PIPE S.= SOUTH. S.F. = SCREENED PORCH SUR = SECONDS. T = TANGENT. I TO = TELEPHONE BOOTH HAS TSB = TRAFFIC SIGNAL BOX . THE TSP = TRAFFIC SIGNAL POLE PROFE TOP - TOlwsm P. UTIL.= UTILITY. U.Y.= UTILITY LLASOMr. U.P.=UTILITY POLE.ITER Y.M.- WATER !. Y.P.= WOOD FENCE. W. WOOD SHED. W.R.= WOOD R". W.V.= A%2XR VALVE. LOO Ig = imum T Las. TER g = CANLas. <;- = CENTRAL ANGLE. ANQLff. LEGEND TYPICAL -- CTVERJSAD OTILITT' Lase C.B.S. = WALL (Cm)". +-� +-+-- C.L.F. = CHAIN Ti m MOM I. Y. = IRON TEM. W.F. = WOW IIMEMCs. = 0.00 = EXISTING ELEVAnOW. SURVEYOR'S NOTES: 1). IF SHOWN, BEARINGS ARE REFERRED TOANASSUHED AfERIDYM BY SMD PLAT IN THE DESCMPTION OF THE PROPERTY, F NOT, -;THEIN BEARINGSARE REFERRED TO COUNTY, TOWNSNPAMPS 2). THE CLOSURE IN THE BOLMAYIRY SURVEY IS ABOVE 1:7WOFT. 3) CERTIFICATE OFAUTHORLZA77ON LS i 79ft d) NORTH BASED ON PLAT NORTH LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY (SURVEY): - THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY .EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFEC77NG THE PROPERTY - THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORD -LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY - BOUNDARY SURVEY MEANS A DRAWING AND/ OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE ANDOR NOT TO SCALE. - EASEMENTS AS SHOWN ARE PER PLAT BOOK UNLESS OTHERWISE SHOWN. - .THE TERM -ENCROACHMENT' MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS. - ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS, SETBACKS AND WILL BE RESPONSIBLE OF SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THEIR APPROVAL FOR AUTHORIZATION TO AUTHORITIES INA NEW CONSTRUCTIONS - UNLESS OTHERWISE NOTED, THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING ANDIOR FOUNDATIONS. FENCE OWNERSHIP NOT DETERMINED. - THIS PLAN OF SURVEY, HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. THE NFIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED LAND TO BE SITUATED IN ZONE: AE' COMMUNITY 120852 /PANEL 0306 / SUFFIX,L DATE OF FIRM: 09/11!2009 BASE FLOOD ELEVATION: B FEET THE SUBJECT PROPERTY DOES LIE IN A SPECIAL FLOOD HAZARD AREA. J VEYOR S CERTIFICATION: HEREBY CERTIFY,THAT THI4'BOCMIDCRYSLONTY` OF ThE`PAUPERTV MSCRIBEDHEREOK RECENTLY BEEN SURVEYED AND DRANN UNDER MY SUPERNSLOHL AND COMPLIES WITH MMAMAN TECHNCALSTAN04ROSASSVTFW BVIWF3CPWA.BGAFVflF SSIONAL LAN) SURVEYORS IN CHAPTER FLOROM AOWWSTRATIVE CODE PURSUANT 70472027, FLORDA STATUTES, 4!c'_ BY: 0&04-2012 A (DATE OFFIEID wcrao PROFESSIONAL LAND SURVEYOR NO.: 8770 STATEOFFLORDA (VAUD COPIES OF THIS SURVEY YWEL BEAR THE EMBOSSED SEAL OF THEAT7ESTANG LAND SURVEYOR). REVISED DHL• - REVISED ON: CERTIFICATION.•.''" VERONIQUE LESTRADE LS MY 6770 �.. STATE OF } n m'si 'HElR4 V Ob'.'_ w __WF tow 161 ` f -__" NE 10Ei1i 81_"' 0 .600 este T4V�+deiYnti FE tll6b SS ABBREVIATION AND MEANING Js = bwL BOX . M.D'.C.R.= HIAIff DAM COUNTY REOCRDS M.E.= JQZNT&NMM E�ffiiT M.N.= HALNAOLE. N.A.P.= NOT A PART OF. HGVD - NATIONAL GEODETIC VERTICAL DATUM. H.T.S.= NOT TO SCALE. /-NO. = HLlNBER. O/S =. OPFSET. O. H. = OVJ30 AD O.H.L.= OVERHEAD UTILITY LINES. O.R.B.= OFFICIAL RECORDS BOCK. - O.V.H.= OVERHANG. PVMT.= FAVJMdD?r. PL.= PLANTER. F/L - PROPERTY LINE. P.C.C.= POINT OP COs'OOND CURVE. P.C.= POINT OF CURVE. PT. = POINT OF TANf ". POC.= POINT OF c0sla CEdwr. P.O.B.= POINT OF BEGZRWING. P.R.C.= POINT OF REVERSE CURVE. PYY = PARKWAY. PER = PER)QKl'NT REPERENZ N7NlvNT. F.L.S.= PROMSIONAL LAW SURVEYOR. P.P.= FOUR POLE P.F.S.= POOL PUIV SLAB P.U.H.= PUBLIC UTILITY EAS012117 (R)= RECORD DISTAMRE. RR.= RAIL ROAD. RES.= RESIZIDR$. R/W= RIGHT-OF-WAY. PAD .= RADIUS CIR RADIAL. RGX.= RANGF. R.O.E.= ROOF OVERHANG RASEN=7. .SEC.= SLCTIOW. STY.= STORY. SWWiK. = SI!>B.7UILTC. S.Z.P.= SET ZROH PIPE S.= SOUTH. S.F. = SCREENED PORCH SUR = SECONDS. T = TANGENT. I TO = TELEPHONE BOOTH HAS TSB = TRAFFIC SIGNAL BOX . THE TSP = TRAFFIC SIGNAL POLE PROFE TOP - TOlwsm P. UTIL.= UTILITY. U.Y.= UTILITY LLASOMr. U.P.=UTILITY POLE.ITER Y.M.- WATER !. Y.P.= WOOD FENCE. W. WOOD SHED. W.R.= WOOD R". W.V.= A%2XR VALVE. LOO Ig = imum T Las. TER g = CANLas. <;- = CENTRAL ANGLE. ANQLff. LEGEND TYPICAL -- CTVERJSAD OTILITT' Lase C.B.S. = WALL (Cm)". +-� +-+-- C.L.F. = CHAIN Ti m MOM I. Y. = IRON TEM. W.F. = WOW IIMEMCs. = 0.00 = EXISTING ELEVAnOW. SURVEYOR'S NOTES: 1). IF SHOWN, BEARINGS ARE REFERRED TOANASSUHED AfERIDYM BY SMD PLAT IN THE DESCMPTION OF THE PROPERTY, F NOT, -;THEIN BEARINGSARE REFERRED TO COUNTY, TOWNSNPAMPS 2). THE CLOSURE IN THE BOLMAYIRY SURVEY IS ABOVE 1:7WOFT. 3) CERTIFICATE OFAUTHORLZA77ON LS i 79ft d) NORTH BASED ON PLAT NORTH LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY (SURVEY): - THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY .EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFEC77NG THE PROPERTY - THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORD -LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY - BOUNDARY SURVEY MEANS A DRAWING AND/ OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE ANDOR NOT TO SCALE. - EASEMENTS AS SHOWN ARE PER PLAT BOOK UNLESS OTHERWISE SHOWN. - .THE TERM -ENCROACHMENT' MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS. - ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS, SETBACKS AND WILL BE RESPONSIBLE OF SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THEIR APPROVAL FOR AUTHORIZATION TO AUTHORITIES INA NEW CONSTRUCTIONS - UNLESS OTHERWISE NOTED, THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING ANDIOR FOUNDATIONS. FENCE OWNERSHIP NOT DETERMINED. - THIS PLAN OF SURVEY, HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. THE NFIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED LAND TO BE SITUATED IN ZONE: AE' COMMUNITY 120852 /PANEL 0306 / SUFFIX,L DATE OF FIRM: 09/11!2009 BASE FLOOD ELEVATION: B FEET THE SUBJECT PROPERTY DOES LIE IN A SPECIAL FLOOD HAZARD AREA. J VEYOR S CERTIFICATION: HEREBY CERTIFY,THAT THI4'BOCMIDCRYSLONTY` OF ThE`PAUPERTV MSCRIBEDHEREOK RECENTLY BEEN SURVEYED AND DRANN UNDER MY SUPERNSLOHL AND COMPLIES WITH MMAMAN TECHNCALSTAN04ROSASSVTFW BVIWF3CPWA.BGAFVflF SSIONAL LAN) SURVEYORS IN CHAPTER FLOROM AOWWSTRATIVE CODE PURSUANT 70472027, FLORDA STATUTES, 4!c'_ BY: 0&04-2012 A (DATE OFFIEID wcrao PROFESSIONAL LAND SURVEYOR NO.: 8770 STATEOFFLORDA (VAUD COPIES OF THIS SURVEY YWEL BEAR THE EMBOSSED SEAL OF THEAT7ESTANG LAND SURVEYOR). REVISED DHL• - REVISED ON: CERTIFICATION.•.''" VERONIQUE LESTRADE LS MY 6770 �.. STATE OF 'HElR4 160h 51 __WF tow ABBREVIATION AND MEANING Js = bwL BOX . M.D'.C.R.= HIAIff DAM COUNTY REOCRDS M.E.= JQZNT&NMM E�ffiiT M.N.= HALNAOLE. N.A.P.= NOT A PART OF. HGVD - NATIONAL GEODETIC VERTICAL DATUM. H.T.S.= NOT TO SCALE. /-NO. = HLlNBER. O/S =. OPFSET. O. H. = OVJ30 AD O.H.L.= OVERHEAD UTILITY LINES. O.R.B.= OFFICIAL RECORDS BOCK. - O.V.H.= OVERHANG. PVMT.= FAVJMdD?r. PL.= PLANTER. F/L - PROPERTY LINE. P.C.C.= POINT OP COs'OOND CURVE. P.C.= POINT OF CURVE. PT. = POINT OF TANf ". POC.= POINT OF c0sla CEdwr. P.O.B.= POINT OF BEGZRWING. P.R.C.= POINT OF REVERSE CURVE. PYY = PARKWAY. PER = PER)QKl'NT REPERENZ N7NlvNT. F.L.S.= PROMSIONAL LAW SURVEYOR. P.P.= FOUR POLE P.F.S.= POOL PUIV SLAB P.U.H.= PUBLIC UTILITY EAS012117 (R)= RECORD DISTAMRE. RR.= RAIL ROAD. RES.= RESIZIDR$. R/W= RIGHT-OF-WAY. PAD .= RADIUS CIR RADIAL. RGX.= RANGF. R.O.E.= ROOF OVERHANG RASEN=7. .SEC.= SLCTIOW. STY.= STORY. SWWiK. = SI!>B.7UILTC. S.Z.P.= SET ZROH PIPE S.= SOUTH. S.F. = SCREENED PORCH SUR = SECONDS. T = TANGENT. I TO = TELEPHONE BOOTH HAS TSB = TRAFFIC SIGNAL BOX . THE TSP = TRAFFIC SIGNAL POLE PROFE TOP - TOlwsm P. UTIL.= UTILITY. U.Y.= UTILITY LLASOMr. U.P.=UTILITY POLE.ITER Y.M.- WATER !. Y.P.= WOOD FENCE. W. WOOD SHED. W.R.= WOOD R". W.V.= A%2XR VALVE. LOO Ig = imum T Las. TER g = CANLas. <;- = CENTRAL ANGLE. ANQLff. LEGEND TYPICAL -- CTVERJSAD OTILITT' Lase C.B.S. = WALL (Cm)". +-� +-+-- C.L.F. = CHAIN Ti m MOM I. Y. = IRON TEM. W.F. = WOW IIMEMCs. = 0.00 = EXISTING ELEVAnOW. SURVEYOR'S NOTES: 1). IF SHOWN, BEARINGS ARE REFERRED TOANASSUHED AfERIDYM BY SMD PLAT IN THE DESCMPTION OF THE PROPERTY, F NOT, -;THEIN BEARINGSARE REFERRED TO COUNTY, TOWNSNPAMPS 2). THE CLOSURE IN THE BOLMAYIRY SURVEY IS ABOVE 1:7WOFT. 3) CERTIFICATE OFAUTHORLZA77ON LS i 79ft d) NORTH BASED ON PLAT NORTH LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY (SURVEY): - THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY .EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFEC77NG THE PROPERTY - THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORD -LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY - BOUNDARY SURVEY MEANS A DRAWING AND/ OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE ANDOR NOT TO SCALE. - EASEMENTS AS SHOWN ARE PER PLAT BOOK UNLESS OTHERWISE SHOWN. - .THE TERM -ENCROACHMENT' MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS. - ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS, SETBACKS AND WILL BE RESPONSIBLE OF SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THEIR APPROVAL FOR AUTHORIZATION TO AUTHORITIES INA NEW CONSTRUCTIONS - UNLESS OTHERWISE NOTED, THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING ANDIOR FOUNDATIONS. FENCE OWNERSHIP NOT DETERMINED. - THIS PLAN OF SURVEY, HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. THE NFIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED LAND TO BE SITUATED IN ZONE: AE' COMMUNITY 120852 /PANEL 0306 / SUFFIX,L DATE OF FIRM: 09/11!2009 BASE FLOOD ELEVATION: B FEET THE SUBJECT PROPERTY DOES LIE IN A SPECIAL FLOOD HAZARD AREA. J VEYOR S CERTIFICATION: HEREBY CERTIFY,THAT THI4'BOCMIDCRYSLONTY` OF ThE`PAUPERTV MSCRIBEDHEREOK RECENTLY BEEN SURVEYED AND DRANN UNDER MY SUPERNSLOHL AND COMPLIES WITH MMAMAN TECHNCALSTAN04ROSASSVTFW BVIWF3CPWA.BGAFVflF SSIONAL LAN) SURVEYORS IN CHAPTER FLOROM AOWWSTRATIVE CODE PURSUANT 70472027, FLORDA STATUTES, 4!c'_ BY: 0&04-2012 A (DATE OFFIEID wcrao PROFESSIONAL LAND SURVEYOR NO.: 8770 STATEOFFLORDA (VAUD COPIES OF THIS SURVEY YWEL BEAR THE EMBOSSED SEAL OF THEAT7ESTANG LAND SURVEYOR). REVISED DHL• - REVISED ON: CERTIFICATION.•.''" VERONIQUE LESTRADE LS MY 6770 �.. STATE OF U. P. 04 r �. N: W.M. LD R Oo ci CZ u') J U N 11.05' . .” 6 20.0' r og`; 75.00' 627.75' F.I.P 112" B,C. F.I.P I!2" NO CAP-�' ONP/L " v s 7.T p NO CAP F.I.P 1/2" - 0) co t • 1 r '�'�� a n� . NO CAP it 04 �' 'ns.Y��`d4„. ��?44 YI 4'a,V. 'V ��Vi °• _.••� N: LD R Oo ci CZ u') J U N 11.05' . .” 6 20.0' vz ONP/L 7.T p - - c ' Q 1.7 - 19.55' 1o.54' N (UNDER o 10.7' CONSTRUCTION) O Ll 11 26:10' 10.501—ON P/L �! 13.48' — o V us - ONE .STORY RES. tea: 1080 (UNDER CONSTRUCTION)' 4;59 10.32' LOT 10 LOT 8ko 11.01' 30.30' N BLOCK 1 BLOCK 1 p o COVERED TERRACE p (UNDER CONSTRUCTION) 4 ', N 15.98' 18 475 �, 39.93' / 10.24' - WALL) .04 (UNDER �4 GLF: 4' C.L.F� CONSTRUCTION} M i' � 0 M r"'• i' BRICK WALK <D o LOT 9 BLOCK 1 0.65' CL — — co N O O __-W .f..D,.. rn BOAT 1 ;NOS.ft iw LIFT ON P/L SLP 1/2" L-R� 7906 Bl FLS OPMA DEPARTMENT OF Rick Scott HEALT John H. Armstrong, MD, FACS Governor State Surgeon General January 15, 2013 Estefania Paoli 1080 NE 105 Street Miami, FL 33138 RE: Contingency Letter Application Document No: AP 1093609 Centrax Permit Number: 13 -SC -1449140 OSTDS Number: 1080 NE 105 St Miami, FL 33138 Lot:9 Block:1 Subdivision: Miami Shores Dear Applicant: This will acknowledge receipt of an application dated 01/09/2013 for a permit to use an existing onsite sewage treatment and disposal system located on the above referenced property. Construction of a pool at the back yard, this permit is subjected to final approval of the new septic system permit AP -1054866, (existing system shall be abandon and new system be installed before the pool construction.) From a review of your completed application, it has been determined your existing system is adequate for the proposed use. If you have any questions on this matter, please call our office at (305) 623-3500. Enclosures cc: Sincerely, I Carlo•lraa -''�r Miami -Dade County Health Department 1725 NW 167 St, Opa Locka, FL 33056 Phone: (305) 623-3500. Fax: (305) 623-3645 . http://www.MyF]oridaEH.com