Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ELC-14-1421
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 215324 Permit Number: ELC -7 -14 -1421 Scheduled Inspection Date: July 03, 2014 Inspector: Devaney, Michael Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Kolasa Hall Miami Shores, FL 33138 -0000 Project BARRY UNIVERSITY Contractor: CITIZEN PROTECTION INC Permit Type: Electrical - Commercial Inspection Type: Rough Work Classification: Addition /Alteration Phone Number Parcel Number 1121360010160 -33 Phone: (305)512 -0700 Building Department Comments INSTALL OF TWO CARD READERS WITH CRASH BARS Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comm 7 TUdi Za /�f Jtkly 03, 2014 For Inspections please call: (305)762 -4949 Page 27 of 33 A i BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795 -2204 Fax: (305) 756 -8972 INSPECTION LINE PHONE NUMBER: (305) 762 -4949 FBC 20 tO Master Permit No. Sub Permit No. f LCA Lt — 11-12,1 El BUILDING In ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL El PLUMBING Q MECHANICAL ❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION El SHOP CONTRACTOR DRAWINGS JOB ADDRESS: Barry University, (Kolasa) City: Mianhi Shores County: Folio /Parcel #: Occupancy Type: Load: Construction Type: OWNER: Name (Fee Simple Titleholder): Barry University Address: 11300 NE 2 Avenue City: Miami Shores State: FL Miami Dade Zip: Is the Building Historically Designated: Yes NO Flood Zone: BFE: FFE: Phone#: Zip: 33161 Tenant /Lessee Name:! Phone#: Email: CONTRACTOR: Company Name: Citizen Protection Inc Phone#: 305.793.4240 Address: 7880 West 20th Ave City: Hialeah State: FL Zip: 33016 Qualifier Name: Arnaldo A. Texidor Phone#: 305.793.4240 State Certification or Registration #: EC13- 004109 Certificate of Competency #: DESIGNER: Architect /Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ t' CD° Square /Linear Footage of Work: Type of Work: CI Description of Work: Addition ❑ Alteration ❑ New ❑ Repair /Replace Installation of two card readers with crash bars C e jam❑ Demolition s Specify color of color thru tile: Submittal Fee '$ Permit Fee $ /in" " ' CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02 /24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards c)f all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2509, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature JIJIAI 1f.,t�it Jk OWNER or AGENT The foregoing instrument was acknowledged before me this day of (SA Ls)I , 20 W=� . by flOSEN11^IAL , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Seal: The foregoing instrumen —1:1 day of CONTRACTOR as acknowledged before me this 20 14. , by who is petsonally known to me or who has produced identification and who d NOTARY PUBLIC: Sign: Print: Seal: oath as a S - a AMAT FEZ Nitta Public - State of Florida o , Expires Aug 28.2013 • (Mr, EE 103505 Bonded Through National Notary Assn. • ***************************** ********* 4tr4w ****** * * ******* *********** **** *** ****** ********************* *lib APPROVED BY dy��� Z GtY Plans Examiner Zoning Structural Review Clerk (Revised02/24 /2014) IVijami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION FORM ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED OR THE VILLAGE MAY MAINTAIN A FILE WITH YOUR INFORMATION FOR A $30.00 FEE PER YEAR. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY Or QUALIFIER'S STATE LIC CARD B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE (CERTIFICATE HOLDER TO BE MIAMI SHORES VILLAGE BLDG DEPT) D. / / COPY OF WORKERS COMPENSATION (EITHER CERTIFICATE OR EXCEMPTION) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT C. COPY OF LIABILITY INSURACE (CERTIFICATE HOLDER MUST BE MIAMI SHORES VILLAGE BLDG DEPT) D. COPY OF WORKER COMP INSURANCE (EITHER CERTIFICATE OR EXEMPTION) YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE HOLDER AS FOLLOW: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 n COMPLETE CO TRAC'TOR'S INFORMATION BUSINESS NAME:' C P-04- BUSINESS ADDRESS: 1 ® 2 °� Z° CITY d c,.\ pc. k STATE L ZIP CODE -3 3 0 1.4 BUSINESS PHONE: (3' (5S ) t Z of C6 FAX NUMBER (3'() 12 -0 CELL P H O N E ( ) \793- L 2_40 QUALIFIER'S NAME: QUALIFIER'S LIC NUMBER: \ Z 3 001 -- Cl —00?-0 ack.c.. c. i tr.1 — paste. At o, . cor, E -MAIL ADDRESS (IF APPLICABLE): Created on 3119109 BY MLDV I RV 3126109 MLDV Aug. 2. 2012 1: 27PM No. 3815 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD 1940 NORTH MONROE STREET TALLAHASSEE FL 32399 -0783 TEBIDOR, ARNALDO ANTONIO CITIZEN PROTECTION INC 33375 NE 4 CT NORTH MIAMI FL 33161 Congratulations! With this license you become one of the nearly one million Floridians Iloeneed by the Department of Business and Professional Regulation. Our professionals end businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business In order to serve you better. For Information about our services, please log onto www.mytlorldailcense.aom. Therey�oou can find more information about our divisions end the regulations that Impact you, subscribe to department newsletters and learn more about the Department's Initiatives. Our mission at the Department is: License Efficiently, Regulate Fahly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida. and congratulations on your new Ilcensel AC ##• 6170010 ggNN • DEBARTMEL' E� rf DETACH HERE • (650) 487 -1395 eT YcoRFL*mpA •• ACi9;:.6.170040 ;DEPA T B1 T' OF •9 SINSa8 A $RQF:ES$ta LT•�Rpt�L.NTION •e -/ 11049972i 'CERTIFIED < j TO ;C • : CONTRACTOR :? TERIDO ', ,j >' 0• . •. • CITIZEN P>{i0T r '�'' �, •r' .J • • • Ia CaR'TXY►xao. vn4or art prov$jrfop. yr ;Ob,4'B9 u itiviieUos aai AUG 31, 2014 I ; •120623.00966 :�.. .. • T111‘,1 DOCI.1f.1ENI HAS A coLo hEU UACKCHOUND • t.11Cii01'IlI1JT1NG • LINE f,TARK'' flAU.NITEO 1>APLA STATE OE FLORIDA II F • UUS • • • gg ....� . ppg p• g& ONN � L R dUL• ATION rCL CItA •R8 LENING HOED SECL12062100966 LICENSE NOR S 130‘043.19.,. ThC,RLRCTRICAL CONTRACTOR Named below IS CERTIFIED • ' "• Under the provisi.ona of Chapter Expiration dater AUG 31, 2014: • • �+ X DOE, • ARNALDO ANTONIO } ;:,3 • C TIZEN PROTECTION INC �, *; . 14.: • • 7 80 WEST 20TH AVE 84.5 HIALEAH FL 3 3 0 3. 6 ••i- 4%1: 1 V • rk•.. ".� •At1e t:ic�a .:13ubibese ••ualifioatiOn I. RICH SCOTT • • . nnviemenR M �t KEN LAWSON RM(!RF:TARY • Local Business Tax Receipt Miami -Dade County, State of Florida -THIS IS NOT A BILL - D0 NOT PAY 45557576` BUsiSiESS: NAms/.00ATION 011,E11 PROTECCION INC 7880.:W2O AVE 45 k11A 33016 OWNER CITIZEN PROTECCION INC EMPloyee(s) 1 RECEIPT NO. RENEWAL 4757671 SEC. TYPE OF BUSINESS 214 RETAIL SALES EXPIRES SEPTEMBER 30, 2014 Must be displayed et place of business. Pursuant to County Code Chapter BA - Art. 9 & 10 PAYMENT RECEIVED BY TAX COLLECTOR $90.00 08/02/2013 TXHS1 -13-- 041121 This Local Business Tax Receipt only confirms payr of the Local Business Tax. The Receipt is not a license, permit or • certification of the holders qualifications, to do business. Holder must comply with any governmental or aerigrrremmantai regulatory laws and requirements which apply to the business. The RECEIPTNb. ebovadmst be displayed on all commercial vehicles l-18 decode Sec Be -270. For more Information. visit Local Business Tax Receipt Miami -Dads County, State Pof Florida 4577186 BUSINESS . RAMIE/LOCATION CVTIZEN PROTECf10N INC 78$0 W 20 AVE 45 HIALEAH FL 33016 OWNER CIN PROTECTION INC Woker(s) 2 RECEIPT NO. RENEWAL 4778487 EXPIRES SEPTEMBER 30, 2014 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 SEC. TYPE OP BUSINESS 196 SPEC ELECTRICAL CONTRACTOR EC13004109 PAYMENT RECEIVED BY TAX COLLECTOR $90.00 08/02/2013 TXHS1 -13- 041124 This Local Business Tex Receipt only confirms payment of the Local Business Tax. The Receipts not um i or with any permit, ore cent fication of the holders qualir requirements which business. Hol comply nongovernmental regulatory laws and requ apply bq fl ass flAiemi -Dade Code Sac Ba -276. The RECEIPT NO. above maitbe displayed on all commercial eA, rt a ! I , • i 4, ;i For more information, visit :, , ; .i, ,' CERTIFICATE OF LIABILITY INSURANCE CITIZ -C OP ID: KM DATE (MMJDDSYYYY) 0710212014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the pollcy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate doe$ not confer rights to the certificate holder in lieu of such endorsement(s). RODUCER ena & Whitney Corp Office na & Whitney, LLC 90 Glades Rd Suite C oca Raton, FL 33432 Citizens Protection, Inc. Ada 1920 E Hallandale Bch Blvd#626 Hallandale Beach, FL 33009 CONTACT NAME: NC (NC. No. Ext): 561 -391 X661 E-MAIL ADDRESS: , No): 5614384551 INSURER(S) AFFORDING COVERAGE NAIL I INSURERA: Bridgefield Casualty Insurance INSURER B : Mt. Hawley Insurance 10335 INSURER C : INSURER D : INSURER E : OVERAGES • INSURER F : RLvi .V11 I\VIYIpCR: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. FOR THE POLICY PERIOD RESPECT TO WHICH THIS TO ALL THE TERMS, iygEXCLUSIONS rRR TYPE OF INSURANCE �SR WVD POLICY NUMBER (IGLICY!YYFYY)F (M ILICY EXP LIMITS GENERALLIABWTY X COMMERCIAL GENERAL LIABILITY PGA0001210 11/19/2013 11119/2014 EACH OCCURRENCE $ 1,000,000 REMISES (Ea Etta ante) $ 50,000 CLAIMS -MADE X OCCUR MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 3,000,000 GGEEN'L AGGREGATE LIMIT APPLIES PER: /7 1 POUCY n JEST ri LOC PRODUCTS- COMP /OP AGG $ 3,000,000 $ AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS —" SCHEDULED AUTOS AUTOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per blerson) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (PER ACCIDENT) $ UMBRELLA LIAB EXCESS LIAR OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED I I RETENT ON $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY A�NYIPR ERRIPAR ERE CUTIVE (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y 1 N N f A 0196- 21684 -0 06/10/2014 06/1012015 WC STATU- 0TH. X I TORY LIMITS I I ER E.L. EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYEE $ 1,000,000 E.L. DISEASE - POLIO' LIMIT $ 1,000,000 ESCRIPTION OF OPERATIONS! LOCATIONS ! VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If more space Is required) arm System Installation, Service, & Repair; License # EC13004109 1 MIAMISH MIAMI SHORES VILLAGE BUILDING DEPARTMENT 10050 NE 2ND ST MIAMI SHORES, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZEDREPRESENTA7NE laillr ACORD 25 (2010105) O 1988 -2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD iSTAR Pr iSTAR eX iSTAR Pro supports up to 16 readers iSTAR Pro is an Irrelligent, powerful 16 -door controller that works with both the C•CURE 800/8000 and C•CURE 9000. iSTAR Pro's strong feature set provides a solution to the most demanding access control applications. Its streamlined design features the latest technology and a minimum of circuit boards to provide a highly dependable, • cost- effect'soluQion for enterprise -wide access control. ••••• • iSTAR ?rqy$ ,s a eneral Controller Module (GCM) which • include% standard 64 MB memory that can be Increased to • • • •••• 128 MBLsing a field►ineteJ& le, industry- standard 64 MB SDRgR/I'rpolule. The.GCM,Gontrols up to two Access Control • • • • Modules (,43M) wi h:saalAppporting up to eight Wiegand or Ryl'rtENrs. Th isalso includes 16 supervised • A • • • •.: inputs'2r1tteight o Tly.rtrggys for door control. iSTAR Pro • • also includes two c66■,•slots, alphanumeric LCD, and • • • • • • DIPpitches for c i :yr jon and diagnostics, as well • • as NPariorts►oeetwor nd•�erial communication ports. •••••• •••• • • • • • • •••• IST R Controllers Powerful, IP- enabled control panel Featur s Thy t Make a Difference: o Suite of highly secure control panels to support enterprise and government applications — from four doors to thousands • iSTAR eX controller features onboard FIPS 140 -2 validated AES encryption, eliminating the need for external encryption boxes o Supports redundant backup of configuration data o Easily add features and enhance functionality with a compact flash slot a LCD provides important controller status and diagnostics information a Equipped with LEDs for each output, Ethernet and serial communication, and onboard "heart -beat" monitor to ensure consistent operation o DHCP support automatically assigns IP addresses for easy installation a Supports multiple cards per cardholder and multiple formats for a highly secure, flexible solution at Compatible with C•CURE® 800/8000 and C•CURE 9000 a STAR Pro is available in rack -mount models iSTAF eX supports up to eight readers STAR eX is a four- or eight -door Ethernet -ready controller that provides FIPS 197 - validated 256 -bit encryption. iSTAR eX is also listed for FIPS 140 -2, the U.S. government's most rigorous standard for cryptographic products. This is ideal for government applications or for any enterprise looking for the highest security available in the industry today. Initially available with four door support, iSTAR eX is easily field upgradable to eight readers using a USB security key. Additional RM readers (5 -8) can be activated by inserting the security key into a USB port located on the panel. iSTAR eX works with C ®CURE 800/8000 and C•CURE 9000 and other Software House controllers to provide the most demanding customers with a solution they can use across their entire corporation. Whether installed at the corporate headquarters with hundreds of employees, or at the regional sales branches with only a few employees, STAR eX ensures that the same security policies and procedures are implemented across the entire corporation. In the same vein, iSTAR eX provides government facilities with a highly secure option for protecting their Sensitive Compartmented Information Facilities (SCIFs) which can be small, classified areas with a limited number of doors. Easy to setup with DHCP /DNS/WINS iSTAR controllers support Dynamic Host Configuration Protocol (DHCP) to simplify installation. DHCP is a communications protocol that lets network administrators centrally manage and assign Internet Protocol (IP) addresses from a central point. When a device is plugged into a different place on the network, iSTAR sends a new IP address to the administrator. For easy setup, iSTAR controllers also support Domain Name System (DNS), which translates domain names into IP addresses, and Windows Internet Naming Service (WINS), a system that determines the IP address associated with a particular computer on the network. Ensure Effective Communication with Clusters iSTAR Pro controllers support Ethernet and RS -232 communication topologies and contain a PC Card Type II (PCMCIA) slot for additional types of communications. ISTAR eX contains two onboard Ethernet ports for communications. Communication is peer -to -peer, meaning that the controllers communicate with one another without the need for host intervention. A single connection from the host supports multiple controllers through a TCP/IP subnet. Clusters are user - defined groups of up to 16 controllers and can be created to enhance security by separating a widely dispersed facility into different controlled areas. A cluster is led by a master controller which manages the primary communication between the host computer and the rest of the controllers within the cluster. The master controller communicates all event and cardholder data between the cluster and the C•CURE 800/8000 and C ®CURE 9000 host. The other controllers in the cluster or "members" communicate through the master to the other controllers in the cluster to link events and control anti - passback in the area secured by this cluster of controllers. To ensure constant security, clusters also feature a secondary communication path in the event the master controller loses communication with the network. Control Security Better with Global Anti - Passback Global anti - passback is critical for ensuring uncompromised security. Using a cluster configuration as described above, the iSTAR controllers can easily share cardholder status and location. The controllers are then able to send an anti - passback violation notice to the C•CURE 800 /8000 system should a cardholder pass a card back to another person to use or if that same cardholder tries to access the same area more than once during a specified period. Similarly, tailgating, or following another cardholder into a secured area without presenting a separate badge, can easily be flagged. Keypad Commands Provide the Ultimate in Flexibility Used with C ®CURE 800/8000, keypad commands provide a powerful way to activate events. These commands include anything from triggering a duress call and sounding an alarm, to locking and unlocking doors, directly from an RM reader keypad. Commands can be configured to require a card presentation and /or a PIN to validate the command. Extended Card Numbers Enhance Security iSTAR controllers support extended card numbers allowing you to comply with certain federal guidelines (such as FIPS 201) that require a Cardholder Unique Identifier (CHUID), which is comprised of multiple field lengths. In addition, iSTAR controllers support card numbers of up to 256 bits, eliminating the need for multiple facility codes, site codes, or offset in order to avoid card duplication. Longer card numbers offer greater protection against card duplication and are especially valuable to customers who require card numbers that exceed ten digits. How Many Cards or What Kind - You Decide Used with C•CURE 800/8000 and C ®CURE 9000, iSTAR controllers allow administrators to assign up to five cards per cardholder record rather than having to create a separate record for each card. Using this powerful feature, users can assign a PIN as one of the cards for a flexible and secure solution. This simplifies the management and maintenance of personnel records. For additional flexibility, iSTAR controllers can support up to 128 card formats system -wide and ten card formats per reader, including smart cards. This expanded ability to use multiple card types (such as 26 -bit, 37 -bit, or Corporate 1000) at a single reader frees customers from having to consolidate or re -issue new cards. Easily Test and Troubleshoot with.: Configuration Diagnostics • • iSTAR controllers include a built -in suite Qf•�;.; diagnostics to test and troubleshoot hard, ar4, components such as inputs, outputs, read: • •; ports, last card read, 13CMCIA cards, and battery charger state. In addition, via the Internet0you ca retrieve real -time status and diagnostics of:' • • • • • controller time/boot time ••• ;' • total /available memory •••••• •0 • • • • • • • connection status • firmware and OS versions • hardware (MAC) and IP addresses • downloaded clearances and cardholders Plus, for easy installation and quick troubleshooting, iSTAR controllers include an LCD. •0• • • •••00• • • • • •• • • • 0• • ••0• • • 0050 • •• • • ••• • 0000 • • •0•• • • •••••• • • •••••• • • • •••••• 5555• • • ••••5 • • ••••5• • • ••..•• • • • 000000 Data Security is Critical iSTAR eX combines AES encryption with the strict guidelines set forth by US government regulations to provide a highly secure solution. AES specifies a FIPS 140 -2 approved cryptographic algorithm that can be used to protect electronic data. iSTAR eX communicates with CoCURE 800/8000 and CoCURE 9000 using 256 -bit FIPS 140 -2 validated AES encryption making it the first security system in the industry to satisfy this rigorous requirement from the federal government. Secure communication for the iSTAR Pro is provided using RSA Data Security's RC4 technology implemented using Microsoft® CryptoAPl. Multi -key authentication for real -time communication and password authentication for use with the local diagnostic configuration utility provide a barrier against intrusion into all iSTAR controllers. Additionally, all iSTAR controllers address the needs of businesses to protect critical security data. With instant database backup and restore capabilities, iSTAR controllers provide a highly reliable security solution and ensure that important data is protected, even during communications failure. Secondary Ethernet Router Easily Upgradeable All iSTAR controllers feature the ability to flash nets functionality directly from the host, ensuring that you always have the very latest technology. Choose an iSTAR architecture that makes sense for your application Providing a security solution that is unsurpassed ih the industry for its versatility and security, iSTAR Pro and iSTAR eX controllers can be used together in the same system. This provides an enterprise solution that recognizes that even the largest corporations have smaller branches and facilities that may need to ui;e the same security standards without enormous overhead. iSTAR and apC controllers can operate together with a CoCURE 800/8000 or CoCURE 9000 host on the same network. Although they cannot communicate dire tly to each other, event linking can easily be configured hrough the host. Wide Area Network Prim. Ethernet Router Local Area Network Ethernet Switch Ethernet Switch Redundant Network IOBase -T or • 100Bavt-T •••••• • • •••••• • • •••••• ••••• • • • • • ••••• ••• • •••• RS -232 System Printer EthemetSwltch RS -232 Ethernet Switch Modem C•CURE 800/8000 t Report Printer Imaging Printer RS-485 Converter Monitoring Station Client • 4 • •• • • • • • •• — ••i• • •••• RS-232 • •• • • • • • STAR Pro ISTAR Pro •••• • •I �1 •�• •• apC/8X Monitor r•• • • I her. • I CQIi$ 4t• ISTAR Pro iSTAR Pro apC/8X Camera ISTAR Pro ISTAR Pro Cluster B WAR 8 a WAR, ISTAR eX iSTAR eX Cluster C STAR eX !STAR eX Alternate master takes over If master panel falls Alternate communication path takes over if primary communication path falls Note: !STAR Pro and (STAR eX controllers cannot exist together in the same cluster. Also, (STAR eX does not support a dial -up modem currently as a primary or alternate communication path. / t i STA Fi P o a ISTAR '.. fir Electrical Power Input 90 to 240 VAC, 47 to 440 Hz, 0.5 A 90 to 260 VAC, 47 to 440 Hz, 0.5 A Power Output (of power supply) 12 VDC at 5.0 A maximum 12 VDC at 6.5 A maximum; Battery Backup Rechargeable NIMH batteries provide backup of memory and RTC for 24 hours, with a 24 hour recharge time Built-in UPS with 17 Ahr SLA battery provides full operational backup for four hours, with a 24 hour recharge time Mechanical Dimensions(HxWxD) 61.6 x 41.9 x 10.2 cm (24.25 x 16.5 x 4.0 in) 61.6 x 41.9 x 10.2 cm (24.25 x 16.5 x 4.0 In) Unit Weight 10.6 kg (23.3 ibs) 16.8 kg (37 Ibs) with battery Construction 16 AWG metal wall mounted locking cabinet with tamper switch on door 16 AWG metal wall mounted locking cabinet with tamper switch on door Inputs /Outputs Supervised Inputs 32 16 Input Expansion Up to 128 additional, using 18 input modules on RM bus Up to 64 additional, using 18 input modules on RM bus Outputs 16 Form C relays, 30 VAC/DC, 2.5A Four Form C relays, 30 VAC/DC, 2.0A, plus four open collector outputs, wet or dry Output Expansion Up to 128 additional, using R8 output modules on RM bus Up to 64 additional, using R8 output modules on RM bus Reader Inputs 16 (Eight - reader model available) Four (optional four additional through RM) Regulatory UL294, UL1076, CE, FCC, RoHS UL294, UL1076, CE, FCC, ROHS, FIPS 140 -2 Environmental Operating Temperature 0° to 50 °C (32° to 122 °F) 5 to 95% RH, noncondensing 0° to 50 °C (32° to 122 °F) 5 to 95% RH, noncondensing Storage Temperature -20° to 70 °C (-4° to 158 °F) -20° to 70 °C ( -4° to 158 °F) Operating and Storage with Battery 0° to 50 °C (32° to 122 °F) -20° to 40 °C (-4° to 104 °F) Heat Dissipation 409 BTU/hr 522 BTU/hr Firmware version up to v3.3 v4.0 or higher up to v3.3 v4.0 or higher v4.1 or higher Number of personnel records with one clearance, one card/person, ten-digit cards 500,000 525,000 1,000,000 1,200,000 Number of personnel records with ten clearances, one card/person, ten -digit cards 295,000 295,000 640,000 680,006 • • • • • Number of personnel records with one clearance, five cards/person, ten -digit cards N/A Number of personnel records with ten clearances, five cards/person, 40 -digit cards N/A 170,000 N/A 375,000 • • • • 410,782 •••• 235 7 , • • 110,000 N/A 250,0310m • • • • 58,5.4•5 • __.... •• • Notes: • •5•• ••1•• • (a) Memory allocation within 'STAR Pro and !STAR eX is dynamic and shared between cardholders, event storage, and configuration intoarntatldh. • • • • (b) To estimate how much space is needed for the personnel database in 'STAR Pro v4.0 and higher and (STAR eX for multiple cards argiiiipi, • • • • extended card capacity, refer to the C °CURE 800/8000 v9.3 README file located in the Member Center on www swhouse com. • • • (c) !STAR can support up to five cards for each cardholder record; each card is independent of each cardholder In the system. ••• • • • I • ••• • •••• • • ••• Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not at products Include all features. Avallebity varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. 2009 Tyco International Ltd. and Its respective companies. All rights reserved. SHn'e9 -DS- 200808- R08 -LT -EN www.swhouse.com •• • • • • • • CE • • •I•••S • • ••51•• • • • •5155• ••5•• • • •ISIS • • •5•••• • • •.5••S • • • SI•••• S300- DIN- RDR2SA Two -Door Interface Description The S300- DIN- RDR2SA module supports one or two doors. It uses standard RS-485 communications and can interface with the following controllers: • CK722 • CK721 -A • CK721 • CK720 /CK705 The S300- DIN- RDF#2SA, also referred to as the RDR2S -A, provides the ability to configt#re supervised 4 -state inputs and unsupervised 2 -state inputs. A total of 10 inputs can be configured as supervised 4- state inputs (normally open or normally closed), or 2 -state inputs. When in physical address mode and used with CK722 or CK721 -A version 3.0, any unused points can be configured as general purpose input/output (I/O) points, possibly eliminating the need to purchase additional I/O modules for certain installations. The RDR2S -A provides power for the card reader hardware. It does not provide power fbr door locking hardware. S300 }DIN- RDR2SA Two -Door Interface Features... •••• : • Witfiditilge no anal witage for power source — From +12 to • • 24VD• � 4t or 16 to 4' : •; •••• • Sup'orf fol RS bus communications at 9600 or 19200 • — Autq,baud rat detestion ;9600 /19200 baud) • •••••• • Easy itst�llati n —1 A'ofl i&s can be mounted on a flat surface, DlMrall •oleln a otirfhBq eentrols' approved enclosure. • Expandai> o modentre1091gn — RDR2S -A modules can be • • cosr4ecie ijogetitt rvie liS -485. •••••• • Tw& 66r access vontaoi Input/output interface — See All • • interface signals aft ftj',cted via plug -in connectors. •• ••••• • Input Point/0 pirt cilia Disassociation — Reader terminal • inieutfqujput (I/ points can be re- assigned from reader - specific •••••• fungtiqpi to gen lei ptirkise I/O points. All ir1tyrLapi signals are connected via plug -in connectors. ••••• • • ••••• Each of the two -door access control Input/output interfaces consists at • Wiegand DataO and Data1 interface • Supervised door monitor switch input, normally open or normally closed, based on wired configuration • Supervised auxiliary access or exit request switch input, normally open • Supervised tamper input • Supervised spare input • Door strike relay, SPDT (Single Pole Double Throw) • Alarm shunt relay, SPDT • Red lamp driver (open collector) • Green lamp driver (open collector) • +12VDC 250mA reader power supply Also, the following inputs are shared by both interfaces (one per module): • Calibration resistor input • Supervised power fail input • Supervised tamper input The following figure depicts the position of the terminal blocks. READER 2 To calibration resistor To power 1, supply Seeable switches Battery Low/Power Fail To S300 bus The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of Its products. ® 2010 Johnson Controls, Inc. www.johnsoncontrols.com 1 of 3 Johnson ) Controls S300- D1N- RDR2SA (Continued) RDR2S -A Sample Configuration The following configuration shows a two-door configuration with the RDR2S -A Interfacing with a CK721 controller. FL, Exit Sensor Door Monitor DOOR 1 U To power soppily RDR2S -A IL_ 1 Reader I Strike CK721 i Reader and I/O Modes In the RDR2S -A the reader and I/O modes are enabled. To DOOR 2 LEDs The RDR2S -A module has 4 LEDs: • Power (POWER): On during normal operation. • Status (STATUS): Blinks every second when module Is operational. • Transmit (XMIT): Blinks when a character is transmitted to the controller's S300 bus. • Receive (RCV): Blinks when a character is received from the controller's S300 bus. Input Point Calibration Termination resistance ranges from 150 Ohm to 2000 Ohm (recommended: 1200 Ohm, 1 %). To calibrate individual inputs, use a command launched from the host. Settable Switches The RDR2S -A has the following settable switches: Wiegand, End -of- Line (EOL), and address switches. Wiegand switch EOL Address switches switches Wiegand Switch When using Wiegand Data0 and Data1 interfaces the Wiegand/ RS-485 switch should be on (up). End -of -Line Switches When the RDR2S -A is used at the end of the RS-485 network it must be set as a "network terminating device." Configuration Switches SW1 When using the RDR2S -A module with the CK721 -A version 3.0 and higher, switches 1 though 8 must be off. Address Switches When used with CK721 -A (versions prior to 3.0), CK721, or CK7201 CK705 controllers, positions 4 to 6 determine module address. When used with CK722 or CK721 -A (version 3.0 and higher) controllers, positions 4 to 8 determine module address. Note: Ensure that the address of the RDR2S -A does not conflict with the address of any other device on the S300 bus. Battery Low /Power Fail The RDR2S -A has an internally derived, 2 -state input that can be used to detect battery low or power fail state. To use this feature, the "Input Terminal 1 - Spare Input 6" (CK721/ CK720 /CK705) or "Power Fail - General Purpose Input" (CK722) must be wired to a power fail monitoring circuit. The internally derived input is in alarm only if the power fail point is also in alarm and power voltage has decreased more than 10% from either 12V or 24V (the system detects 12 versus 24 nominal voltage automatically). Note: For use only with 12VDC or 24VDC battery- backed power supply. Technical Specifications P "CHp#on SpegificatibtM ,u , , Input Power +12 to +24VDC or 16 to 24VAC at 24W Reader Interface • 2-wire Wiegand (up to 256 bits) • 12VDC, 250mA (typical), 500mA (peak) • Red indicator • Green indicator General Purpose Inputs Resistive load Relay Outputs 1A max. 0- 24VDCNAC, 25VA max Red LED /Green LED Outputs 50mA max. 0- 24VDC. See °Caution° below. Communications 2 or 3-wire RS-485 Certifications FCC Part 15, Class B CE Mark Click Mounting Specifications DIN rail or flat surface Dimensions 5.7 H x 5.9 W x 2.213 inches • 14.4 cmx15.Ocrs s5.5em) •••• Ambient Temperature 32° to 122°F (0°ito 50°00) • Humidity 10 to 90% non- cpndensirr1 • ir Ventilation Cabinets required 'Instilment of air offer all exposed surfaces • • • • • • • •••••• •• • IMPORTANT: The Red LED /Green I.i!r en collect%pytpdts can be damaged with the use of aitema4fflcturrent (AC) • potentials as low as 1VAC. The LED othpetban only be • • connected to direct current (DC) loadscleto24VDC. • • ..• • Ordering Information C. - • • • • • •••• • • Part Number , = - ' Description" S300- DIN- RDR2SA 2-door interface, supervised inputs, outputs. The RDR2S -A module is set as a network terminating device when switch position 2 and switch position 3 are turned on (up). The performance spedfications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2010 Johnson Controls, Inc. www.Johnsoncontrols.com 2 of 3 • • •••••• • • •••••• • • • 000000 ••••• • • 00000 • • •••••• • • •••••• • •. •••••• Related Documentation S300- DIN- RDR2SA Hardware Installation Manual S300- DIN- RDR2SA Address Mode Configuration Technical Bulletin CK721 -A Installation and Operation Manual CK721 Installation and Operation Manual CK722 Hardware Installation Manual CK722 Commissioning Guide CK720 Network Controller Installation and Operation Manual CK705 Network Controller Installation and Operation Manual •••• • • • •••••• •••• • •• • • . • • • •••••. •••••• • • ■ • • • • • • • • • • •••••• •••••• •• • • • • • •••• ••••• • • • • •• • • •••••• OOOOO • •••• • • • • •••••. •••• •••• • • • OOOOOO O • • • •••••• • • ••• . •• •••••• • • • • •••• • • • • The performance specifications are nominal and conform to acceptable Industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. m 2010 Johnson Controls, Inc. www4ohnsoncontrols.com 3 of 3 AL1024ULACM, AL 1024ULACMCB Power Supply /Chargers w/Multi- Output Access Power Controllers Rev. DSAL1024ULACM - AO6F Overview • The AL1024ULACM / AL1024ULACMCB converts an 115VAC 60Hz input into eight (8) independently controlled 24VDC Fail -Safe and/or Fail- Secure outputs with a total of 10 amp continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. These units will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail -Safe and/or Fail- Secure modes. The units are designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. AL1024ULACM • Eight (8) independently controlled fuse protected outputs. AL 1024ULACMCB • Eight (8) independently controlled PTC protected outputs. • Class 2 Rated power limited outputs. Specifications • 24VDC ® 10 amp supply current. • Power supply input options: a) One (1) common power input for ACM8/ ACM8p and lock power (factory installed). b) Two (2) i olated power inputs - One (1) to power the ACM8 /ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total). • Eight (8) Access Control System trigger inputs. Input options: a) Eight (8) normally open (NO) inputs. • • b) •Eig t 8) open collector inputs. • • c) Any cgmbinatiofi'4f the above. Eigl$'(t n4epidentry controlled outputs. O u t p u t o p t i o n s . : , : a) Eight {8) Faili$aae and/or Fail- Secure power outpuStc • b)•Eigltt,(8) folan Q" 5 amp rated relay outputs CALK0241JLAf only). c) Any comlbifl2len of the above. • Eig,Tit.(81 au*illtntetwer outputs (unswitched) • Oulmtratingsi •' • "s-4l4 s are rated ga 3.5 amp (AL1024ULACM). - PTCs are rated @ 2.5 amp (ALI 024ULACMCB). • Input 115VAC 60Hz rated @ 4.4 amp. • ACM8 board main fuse is rated at 10 amp. • Filtered and electronically regulated outputs (built -in power supply). •• . ••...• •...• • • ••.•• • • •..... • • • Short circuit and thermal overload protection. • Red LEDs indicate outputs are triggered (relays energized). • Fire Alarm disconnect (latching or non - latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL). • Green LED indicates when FACP disconnect is triggered. • Built -in charger for sealed lead acid or gel type batteries. • AL1024ULXB (Power Supply Board) maximum charge current 3.6 amp. • Automatic switch over to stand -by battery when AC fails. • Zero voltage drop when unit switches over to battery backup (AC failure condition). • AC fail supervision (form "C" contact). • Battery fail and battery presence supervision (form "C" contact). • AC input and DC output LED indicators. • Enclosure accommodates up to two (2) 12AH batteries. Agency Approvals UL Listed for Access Control Systems Units (UL 294). CUL Listed - CSA Standard C22.2 No.205 -M1983 Signal Equipment. MEA MEA - NYC Department of Approved Buildings Approved. CSFM - California State Fire Marshal Approved. 0000000 °0000 000000 00000°0° 0 0 0 0°0°0° 0°0°0°0°0°0° 000000 °0°0°0 0°0°0 Enclosure Dimensions 15.5 "H x 12 "W x 4.5 "D , 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 0 0 0 0 00 00 00 00 0 0 0 0 000° 000000 .. • • . • •• • • • •• 000000 •.•• •• ....•• .... • . •••• . •...• • ••.••. .• • •.• .• ••• • • •••• • • • •• • •• • •... • • •••• • • • ..• • •••• • . • • •....• • • •...•. • • • 000000 •.... .• •...• • • •....• • • •...•. • • • .•...• Altronic Corp. - 140 58th Sheet. Proollyti, NY 11, 0 .718 67 -8181 • 888-258-7669 • altronir.com www. GE- lnterlogix. com Overview The GE lnterlogix 1078 Series Steel Door contacts are designed specifically for use in the steel doors commonly found in commercial building applications. The unique housing design features a rugged unibody construction with flexible ribbed sides for quick, secure installation without gluing. The magnet housing isolates the magnet from the surrounding steel for maximum gap distances, both make and break Over seven models including: Wide Gap, SPDT, DPDT, and Biased for High Security applications make the 1078 Series the most widely used and comprehensive line available. On available models a terminal connection (1 makes installation easier. Simply strip the wire, insert it into the terminal block and tighten. The terminal accepts any wire the from 14 to 22 gauge, and has a unique one piece design for added strength. An optional Rare Earth Magnet is available. It is designed for use m metallentry/exit doors with a channel in the top of the door. The rnognet eliminates the need to put amounting hole in the door channel. The flexible magnet housing can be compressed to accommodate a variety bfchannel widths for Old, easy installation. Adhesive is recommended. Architectural The contact contains a hermetically sealed magnetic reed switch._; and Engineering me— he reed shall be potted in the contact. housing with a Spec cations polyurethane basedcornppurfd Contact and magnet housing shall Snap -lock into 2 /4" or l " dia hole Housings s�(Ebe molded 4f •. • • flame retardant ABS plast.dine, c. Color of housings shall be off- white, •• • • • • • •telto)anybrown. The magnet shall be made ofAlnico V • greybrJ + •.. • • • • • +. Rare° r th Magnet shall be made of neodymlkrrrt iron boron • • Designed Snaj?if'gt�E tneulativn bushing for tight fit and maximum gap •••• fora�►M ; • • SteeFHodra: nrseef. • ••.•( ••• • • . tot 1? 8! itt i and f net plastic housings are cbnsfractdd of '� >7 • .: one pi tte'of thick- walled ABS plastic ! for maximum strength • ••.••• ..••. •. andp'�r�:rlty • ••• • .• • •.,. Productlnformation Steel Door Contact 3/4" and 1" contacts 1078/1076 Series Optional 1840 Rare Earth Magnet Standard Features o Fly leads and terminal options available o Designed specifically for use in steel doors o Special ribbed sides allow for easy installation o Rugged unibody construction for maximum durability and reliability o Terminal models available for easier installation o Regular, Wide Gap, SPDT, DPDT, and High Security models available o Rare Earth Magnet designed for steel door with top channel available Model numbers' 1076, 1076W ,1076C,1076CW,10760,1078,1078W, 107t1C,1178C1; (101078,1078C1W Steel Door Contact 37," and I" contacts 1078/7076 Series Dimensions Models: (R)1078, 1078W, 1076, 1076W, 1076D Models: 1078C, 1076C, 1076CW, 1076CH Models: 1078CT,1076CTVV,, (R) prefix indicates Rare Earth Magnet L 1.125' I 286 cm 1.125° 2.86 cm I 1.125° 286 cm 1.00° 2.54 cm 1.563' 3.97 cm Magnet Part No. 1921 (included) 1.563' ,J 375° I 3.97 cm 1.962 cm Ordering Information Model Dia'. 1.625' 4.13 cm .875° 2.22 cm T 1.91 cm Magnet Part No. 1921C (included) r 1.56' 10.64cm 0.375' 3.96 cm 1Loop Type 1076 1" Open or Closed 1076W 1" Open or Closed 1076D 1" Open or Closed 1078 1" Closed 1078W 1" Closed 1076C 3/4° Open or Closed 1076CW 3/4° Open or Closed 1078C 3/4" Closed (R)1078 1" Closed 1078CT 3/4° Closed 1078C1W 3/4° Closed * Gap distances are nominal make distance ±20 %. Gap specifications are for switch to make. Break distance is approximately 1.1 to 1.5 times make. 0.938' k- I 2.36 cm I 0.75' 1.91 cm Magnet Part No. 1929 (included) Electrical Config. SPDT SPDT DPDT N/0 N/0 SPOT SPDT N/0 N/0 N/O N/O Specifications Form A: (R)1078, 1078W, 1078C, 1078CT, 1078CTW Voltage 100V AC/DC max. Current 0.5A max. Power 7.5 W max Form C: 1076, 1076W, 1076D, 1076C(D), 1076CW, 1076CH Voltage 30VAC/DC max Current 0.25A max. Power 3.0 W max Rare Earth Magnet Hole Required •'t Contact Magnet 1" x 1.125" 1" x 1.125" 1" x 1.125" 1" x 1.125" 1" x 1.125" .75" x 1.125" .75" x 1.125" .75" x 1.125" 1 "x1.125" .75" x 1.625" .75" x 1.625" 1" x 1.563" 1" x 1.563" 1" x 1.563" 1 "x1.563" 1" x 1.563° .75" x 1.563" .75" x 1.563" .75" x 1.563" 1" x 1.563" .75" x 1.56" .75" x 1.56" 1 t 1.813° 4.80 cm i 0.5° 0.625° 1.27 cm 1.59 cm 1.625° m 4.13 cm I he Legs cutleay r Height Adjustment Protected by U.S. Patent 5,844,458. Gap Distance' Wood'` Steel` Rare Earth 1" Up to 1/2 2" Up to 1" 3/4 Up to 3/8 1" Up to 1/2' 2" Upto1" 7/8 Up to 3 /8° 2" Up to 3/4" N/A 1/2 Up to 5/8 Up to 5 /g° Up to 5/8 LISTED Color M, N, G M, N, G M, N, G M, N, G M, N, G Up to S/8 M,N,G M, N M, N, G 1" Up to 1/2 Up to 4/(• M, N 7 /$• 1/2i... • 5/8" 5 5 5 5 •• 5 /s° 3,7/4" ° • N /A :.•••. N - • - • • • ..•00• • •• •• •• • •• ••555• • • • • • ••••• .5.0.5 •• • • • • 00000 • • • • •••• • • •••• •••••• • 5.501• www.GE- Interlogix.com ©2002 GE Intedogoc. M trademarks are properties of their owners. C- 3817- FLG10K -0403 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800 -648 -7424 Faxback: 800-483-2495 2266 Second Street North North St. Paul, MN 55109 Phone: 651-777-2690 USA & Canada: 800-777-5484 Technical Service: 800 - 777 -2624 .••. • • •••• • •• • • •••• liElnterlq .• • • • • •••• • • • 5.555• 2 DS160 Series High Perrormance'Request -to -exit Detectors Region Europe Certification CE 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000 -4 -2: 1995 +Al: 1998 +A2: 2001, EN61000 -4 -3: 2002 +Al: 2003, EN61000-4-4: 1995 +A1: 2000 +A2: 2001. EN61000-4-5: 1995 +Al: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001, EN61000 -4- 11:1994 +A1: 2001, EN60950 -1: 2001 2004/108/EC; EN 50130 - 4:1996 +A1:1998 +A2:2003; EN 60950 - 1:2006 USA Europe UL ALVY: Access Control Systems Units (UL294) Complies with EN50131 -1 Grade 2 I. st l "la1k �iit igut tion' r (4 ft) EIo ©000 000000 I' c oft) 0 ©0000 El 0o .m Front View Mounted on wall above door and mounted on ceiling .75 m (2.5 ft) in front of the door. 1.5 m (5 ft) Side View The higher that you mount the unit, the latger the coverage area. Do not mount the DS160/0S161 more than 4.6 m (15 ft) above the floor. Side view of coverage pattern with the un�t mounted at 4.6 m (15 ft) above the floor with the lens pointed straight down. 3m (10 ft) .75 m (2.5 ft) Side View •• • • • • • • • • • • •• •• • • •••• • • •••• 5.55•• • • • • 5555•• • 5 • • • .5'm • 1 • • .V • t4 • •••• • • The higher that you mount the unit' ihe•larger the, •: coverage area. Do not mount the M.946t1/DS16 ')1ore'than 4.6 m (15 ft) above the floor. • • "'• • • Side view of coverage pattern with the unit moan '&eat at 4.6 m (15 ft) above the floor with the lent pointed straight down. • • • • • •••5.5 Intrusion Systems 1 DS160 Series High Perrorrnance'Request- io -exlt De Lectors DSI60 Series High Performance Request -to -exit Detectors The DS160 Series consists of the DS160 Detector (light gray) and the DS161 Detector (black) specifically designed for Request -to -exit (REX) applications. With features such as timers, door monitor with sounder alert, and pointable coverage, the DS160 and DS161 have the flexibility to meet the most stringent REX requirements. The exclusive Sequential Logic Input (SLI) provides added security that is not offered in any other REX device. Ofl� '��191�t4 IIII liNh ��� 1Functio xl' Sequential Logic Input (SLI) • •The SLI feManal allows connection of a second device to ; °°°° : require sequential 4ettefign. This eliminates the possilelitoblat an object that is slid through the door or • '• underneath the door will 4ctivate the detector. This input • •••• can alsp be used to roc%�R • e sensor if motion is present ••••• outsiSQtlltpremisp� :. • • • . ••••• DoorI'1ertitor •••• • The selt8Pcan monitor: door contact to allow special • controlef the inteffll telly. For example, if the door is '• open: i •within the'1t1ay't me period, the sensor can be • • •• •••• programmed to hit tIlb•gmer. If the door is not opened withtrla pacific tiri a period, the relay can be programmed to deactivate. ► Door monitor with sounder alert • Sequential Logic Input (SLI) • internal vertical pointability • Wrap - around coverage pattern with precise pattern control • Up to 64 second adjustable latch time • Selectable relay trigger mode • Selectable fail -safe or fail - secure modes • Adjustable sounder volume • Activation LED Sounder Alert An integrated sounder can be programmed to activate if the door is left open too long. The sounder volume is fully adjustable to 85 dB. Keycard Input The keycard input allows the sensor relay to be controlled from an external source, such as an access control system or card reader. www.boschsecurity.com DS160 Series High Performance Request -to -exit Detectors 13 Coverage Information The coverage (detection area) varies depending on the mounting height above the floor, angle of the lens, and whether the unit is mounted on a wall above the door or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x 10 ft) The coverage patterns for the detector at a height of 2.3 m (7.5 ft) are shown. The coverage pattern increases or decreases with height and detector alignment. Note When you mount the unit on the wall and the lens points straight down, some detection zones point toward the wall and do not detect movement. The diagrams depict views of the coverage pattern with the detector mounted at 2.3 m (7.5 ft) above the floor with the lens pointed straight down. Zones that are pointed toward the wall are not shown. ical Environmental Operating Temperature: ions -29 °C to +49 °C ( -20°F to +120°F) For UL Certificated installations, 0 °C to +49 °C ( +32 °F to +120°F) Radio Frequency Inter- No alarm or setup on critical frequencies in the ference (RFI) Immunity: range from 26 MHz to 1000 MHz at 50 V/m Complies with Environmental Class II (EN50130 -5) Mechanical Dimensions: 4.5 cm x 17.1cm x 4.4 cm (1.80 in. x 6.75 in. x 1.75 in.) Material: High impact ABS plastic enclosure Modes Power Loss De- Programmable fail -safe or fail - secure modes. fault: Timer: . Electrical'; •' •Curren/lir : • •••.• • • • Programmable reset accumulative or non -reset counting mode. • •• 8 mA nrrriiinal tandby current, 39 mA at 12 VDC in alarm. • • Voltage: • ••••• •• • .. • • Alarm 0uutpu : • • ••••• •••• • • Indicatojl••• • •••• • • Relay Latch • •••• Time:.. • • • • ••• •••• • • a,... • 12 V (l 1DS: to 30 VAC or VDC Two Fcf4rA t2lay contacts each rated 1 A at 30 VAC or VDC tot resistive loads 1 activauonl4D Adj4V412 from 0.5 sec to 64 sec. • •••••• • • • •• Ordering Information DS160 Request -to -exit Detector Light gray enclosure. For use in request -to- exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door monitor with sounder alert, and pointable coverage. DS160 DS161 Request- to-exit Detector Black enclosure. For use in request -to -exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door monitor with sounder alert, and pointable coverage. DS161 Accessories TP160 Trim Plate A light gray trim plate used when mounting the detector over a standard single-gang box. T'160 TP161 Trim Plate A black trim plate used when mounting the sensor over a standard single-gang box. TP161 www.boschsecurity.com 4'IDS160 Series High Performance Request -to -exit. Detectors American Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0098 Fax: +1 585 223 9180 securlty.sales®us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5800 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Pam +31 40 2577 330 emea.securitysystems®bosch.com www.boschseturity.com ® Bosch Security Systems Inc. 20101 Data subject to change without notice 71138242827 [Cur: en-US, V14, 2 Dec 2010 Ada-Pacifies Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 8258 5511 Fax: +65 8571 2898 apr.securitysystems®bosch.com www.boschsecurlty.com •• • • • • • • • •• •• • • 000000 •••• • • •••• •••••• • • • •••• •• • • • • • • ••• • • •••• • • • a • •• • • • •• • •• • • ••• • •••• • • ••• • • • 000000 • • 000000 • • • 000000 ••••• • • • • •••••• • • • • •••••• UL 1034 field se ectable field selectable burglary listed (fail secure / fail safe) (12 or 24VDC) • • • • • • • • •• 35555• 9600 Genesis III'" •••• • •••• • • •• • • • • • •• ...• • • •••• • •• • ••■ •••• • • •••• The original completely surface mounted solution - updated! With a new enhanced design, the 9600 series Genesis IIIT"' continues to set the standard for surface mounted electric strikes. The 9600 accommodates rim exit devices in metal or wood jambs. The 9600 features an internally mounted solenoid and two stainless steel, independently - operating locking mechanisms. The 9600 is easy to install, with all components encased in the 3/4" thick stainless steel housing, requiring no cuts to the jamb prior to installation. Specifications 01414134 burglary- resistant listed •• ANSI /BHMA, A156.31 Grade 1 ( #E09731, ;•3732) $ SP4gnt # 6,390,520 • • •••••• Fume application • ..Metal • •Waod • : Fjectrical • AS Amps @ 12VDC continuous duty • .25 Amps @ 24VDC continuous duty 37 www.hesinnovations.com Standard Features • Completely surface mounted • Stainless steel construction • Tamper resistant • Static strength 1,500 lbs. • Dynamic strength 70 ft -lbs. • Endurance 500,000 cycles • Feld selectable fail safe/fail secure • Dual voltage 12 or 24 VDC • Horizontal adjustment • Non - handed • Internally mounted solenoid • Accommodates up to 3/4" pullman latch • Ave year limited warranty [228.6] 9" [19.1] 3/4" [44.51 1 -3�4" Optional Features • LBM - Latchbolt monitor • LBSM - Latchbolt strike monitor Accessories • 9500/9600 108 - Spacer plate • SMB - Surface mounting box • 2001 M - Plug -in bridge rectifier • 2004M - ElectroLynx® adapter • 2005M - SMART Pac IP' • 2006M - Plug -in buzzer Finishes • 630 - Satin stainless steel finish • 605 - Bright brass finish • 606 - Satin brass finish • 612 - Satin bronze finish • 613 - Bronze toned finish • 629 - Bright stainless steel finish,, • • • • • • . • • •S. •• • • •••• • • •••• • •• • • • • • . •••• • •••• • • • • •• .. • •• • •••• • • •••• • •• .. ••• • •••• • • • • • • . . • • • • • •••••• • • . Customer Support 800.626.7590 38 \PECE JUL 012014 iSTAR Pro supports up to 16 readers iSTAR Pro is an intelligent, powerful 16 -door controller that works with both the C•CURE 800/8000 and C•CURE 9000. STAR Pro's strong feature set provides a solution to the most demanding access control applications. Its streamlined design features the latest technology and a minimum of circuit boards to provide a highly dependable, cost - effective solution for enterprise -wide access control. STAR Proysn a General Controller Module (GCM) which • lncludwaidard 64 MB memory that can be increased to °°°° :128 MB using k field- imsteTa%e, industry- standard 64 MB .SDRAIVIr eldtte. The G•CM controls up to two Access Control • • Modules ciNCM) with aacq supporting up to eight Wegand • or RM riders. The At?Viielt8 includes 16 supervised inputs d eigtt outpolf r'elayg for door control. iSTAR Pro • also includes two PCRAtM Ws, alphanumeric LCD, and •DIP svditcnes for conkfIe4bp and diagnostics, as well •as various network and Metal communication ports. • • • • • • • •• • • • ••• •••• • • •••. • iSTAR Controllers Powerful, IP- enabled control panel Features That Make a Difference: ® Suite of highly secure control panels to support enterprise and government applications — from four doors to thousands • iSTAR eX controller features onboard FIPS 140 -2 validated AES encryption, eliminating the need for external encryption boxes • Supports redundant backup of configuration data • Easily add features and enhance functionality with a compact flash slot • LCD provides important controller status and diagnostics information ® Equipped with LEDs for each output, Ethernet and serial communication, and onboard "heart- beat" rinonitor to ensure consistent operation • DHCP support automatically assigns IP addresses for easy installation • Supports multiple cards per cardholder and multiple formats for a highly secure, flexible solution • Compatible with C•CURE® 800/8000 and d•CURE 9000 • iSTAR Pro is available in rack-mount models iSTAR eX supports up to eight readers iSTAR eX is a four- or eight -door Ethernet -ready controller that provides FIPS 197 - validated 256 -bit encryption. iSTAR eX is also listed for FIPS 140 -2, the U.S. government's most rigorous standard for cryptographic products. This is ideal for government applications or for any enterprise looking for the highest security available in the industry today. Initially available with four door support, iSTAR eX is easily field upgradable to eight readers using a USB security key. Additional RM readers (5 -8) can be activated t y inserting the security key into a USB port located on the panel. iSTAR eX works with C•CURE 800/8000 and C•CURE 9000 and other Software House controllers to provide the most demanding customers with a solution they can use across their entire corporation. Whether installed at the corporate headquarters with hundreds of employees, or at the regional sales branches with only a few employees, iSTAR eX ensures that the same security policies and procedures are implemented across the entire corporation. • • • In the same vein, STAR eX provides government facilities with a highly secure option for protecting their Sensitive Compartmented Information Facilities (SCIFs) which can be small, classified areas with a limited number of doors. • • • • • Easy to setup with DHCP /DNS/WINS iSTAR controllers support Dynamic Host Configuration Protocol (DHCP) to simplify installation. DHCP is a communications protocol that lets network administrators centrally manage and assign Internet Protocol (IP) addresses from a central point. When a device is plugged into a different place on the network, iSTAR sends a new IP address to the administrator. For easy setup, iSTAR controllers also support Domain Name System (DNS), which translates domain names into IP addresses, and Windows Internet Naming Service (WINS), a system that determines the IP address associated with a particular computer on the network. Ensure Effective Communication with Clusters iSTAR Pro controllers support Ethernet and RS -232 communication topologies and contain a PC Card Type II (PCMCIA) slot for additional types of communications. iSTAR eX contains two onboard Ethernet ports for communications. Communication is peer -to -peer, meaning that the controllers communicate with one another without the need for host intervention. A single connection from the host supports multiple controllers through a TCP/IP subnet. Clusters are user - defined groups of up to 16 controllers and can be created to enhance security by separating a widely dispersed facility into different controlled areas. A cluster is led by a master controller which manages the primary communication between the host computer and the rest of the controllers within the cluster. The master controller communicates all event and cardholder data between the cluster and the C•CURE 800/8000 and C•CURE 9000 host. The other controllers in the cluster or "members" communicate through the master to the other controllers in the cluster to link events and control anti - passback in the area secured by this cluster of controllers. To ensure constant security, clusters also feature a secondary communication path in the event the master controller loses communication with the network. Control Security Better with Global Anti - Passback Global anti- passback is critical for ensuring uncompromised security. Using a cluster configuration as described above, the iSTAR controllers can easily share cardholder status and location. The controllers are then able to send an anti - passback violation notice to the C•CURE 800/8000 system should a cardholder pass a card back to another person to use or if that same cardholder tries to access the same area more than once during a specified period. Similarly, tailgating, or following another cardholder into a secured area without presenting a separate badge, can easily be flagged. Keypad Commands Provide the Ultimate in Flexibility Used with C•CURE 800/8000, keypad commands provide a powerful way to activate events. These commands include anything from triggering a duress call and sounding an alarm, to locking and unlocking doors, directly from an RM reader keypad. Commands can be configured to require a card presentation and /or a PIN to validate the command. Extended Card Numbers Enhance Security iSTAR controllers support extended card numbers allowing you to comply with certain federal guidelines (such as FIPS 201) that require a Cardholder Unique Identifier (CHUID), which is comprised of multiple field lengths. In addition, iSTAR controllers support card numbers of up to 256 bits, eliminating the need for multiple facility codes, site codes, or offset in order to avoid card duplication. Longer card numbers offer greater protection against card duplication and are especially valuable to customers who require card numbers that exceed ten digits. How Many Cards or What Kind - You Decide Used with C•CURE 800 /8000 and C•CURE 9000, iSTAR controllers allow administrators to assign up to five cards per cardholder record rather than having to create a separate record for each card. Using this powerful feature, users can assign a PIN as one of the cards for a flexible and secure solution. This simplifies the management and maintenance of personnel records. For additional flexibility, iSTAR controllers can support up to 128 card formats system -wide and ten card formats per reader, including smart cards. This expanded ability to use multiple card types (such as 26 -bit, 37 -bit, or Corporate 1000) at a single reader frees customers from having to consolidate or re -issue new cards. Easily Test and Troubleshoot with Configuration Diagnostics iSTAR controllers include a built -in stsitb •gf diagnostics to test and troubleshoot4hardvPare components such as inputs, outputs: reagileC ports, last card read, PCMCIA cardspariolseettery charger state. In addition, via the Interaetryou can retrieve real -time status and diagnostyr4caf.: • controller time/boot time • total /available memory • connection status • firmware and OS versions • hardware (MAC) and IP addresses • downloaded clearances and cardhoidess • • • ••• • • •••• • •••• • • • • • •• • • • •• • •••• • • •••• • •• • • ••• • •••• Plus, for easy installation and quick trroubles'hootingp • • ..• iSTAR controllers include an LCD. • • • • • • • • • • • • Data Security is Critical !STAR eX combines AES encryption with the strict guidelines set forth by US government regulations to provide a highly secure solution. AES specifies a FIPS 140 -2 approved cryptographic algorithm that can be used to protect electronic data. iSTAR eX communicates with C•CURE 800/8000 and C•CURE 9000 using 256 -bit FIPS 140 -2 validated AES encryption making it the first security system in the industry to satisfy this rigorous requirement from the federal government. Secure comnilunication for the !STAR Pro is provided using RSA Data Security's RC4 technology implemented using Microsoft® CryptoAPl. Multi -key authentication for real -time communication and password authentication for use with the 1pcal diagnostic configuration utility provide a barrier against intrusion into all iSTAR controllers. Additionally, all STAR controllers address the needs of businesses to protect critical security data. With instant database backup and restore capabilities, STAR controllers provide a highly reliable security solution and ensure that important data is protected, even during communications failure. Secondary Ethernet i l3rimary Ethernet Ethernet Ethernet Switch Redundant Network 10Base -Tor 100Base -T • • •••••• • • • • • •••••• • • • • I • I • • • •••••• • •• • •••• Router Easily Upgradeable All !STAR controllers feature the ability to flash new functionality directly from the host, ensuring that you always have the very latest technology. Choose an iSTAR architecture that makes sense for your application Providing a security solution that is unsurpassed in the industry for its versatility and security, iSTAR Pro and iSTAR eX controllers can be used together in the same system. This provides an enterprise solution that recognizes that even the largest corporations have smaller branches and facilities that may need to use the same security standards without enormous overhead. iSTAR and apC controllers can operate together with a C•CURE 800/8000 or C•CURE 9000 host on the same network. Although they cannot communicate directly to each other, event linking can easily be configured through the host. - r Wide Area Network Router Local Area Network RS-232 RS-232 System Printer C•CURE 8008000 Server RS-485 Converter Monitoring Station Client • • • • •• • • • • • •• •••• • • •••• • Phdig,ifiagintClient I Capture Works�fation • • • • • _•st.,_._ apC/8X CCTV 11 Matrix Switcher Monitor • Glitter A !STAR PM • •ISrRR Pro •- —• •-• •••• • • • ••• _' • • • • • • • ocaix apC /8X Camera !STAR Pro ISTAR Pro Cluster B ii II 11 II II II II II • (STAR eX a7ARex !STAR eX Cluster C arnsex e I !STAR eX Alternate masterltakes over If master panel falls 'Alternate communication path takes over If primary communication path falls Note: (STAR Pro and (STAR eX controllers cannot exist together In the same cluster. Also, (STAR eX does not support a deal -up modem currently as a primary or alternate communication path. STAR Pr Electrical tiSTAR eX c15 =yJ. Power Input 90 to 260 VAC, 47 to 440 Hz, 0.5 A Power Output (of power supply) • VDC at* 9 A taximum • 12 VDC at 6.5 A maximum; Battery Backup Mechanical Dimensions (H x W x D) batteries provide backs fir 24 hogs, with a 24 h 6x4i9x . (24.25 1165 Unit Weight Built -in UPS with 17 Ahr SLA battery provides full operational backup for four hours, with a 24 hour recharge time 61.6 x 41.9 x 10.2 cm (24.25 x 16.5 x 4.0 in) 16.8 kg (37 Ibs) with battery Construction 116 AWG rnetalWall mounted locking cabinet with 16 AWG metal wall mounted locking cabinet with tamper switch of door tamper switch on door Inputs /Outputs Supervised Inputs 16 Input Expansion to 12$ addlilonal, tieing 18 input module on RM bus _ Up to 64 additional, using 18 input modules on RM bus Outputs Output Expansion i)p to 1',28 fAM bus Four Form C relays, 30 VAC/DC, 2.0A, plus four open collector outputs, wet or dry Up to 64 additional, using R8 output modules on RM bus Reader Inputs Regulatory =rea el available) Four (optional four additional through RM) Environmental UL294, UL1076, CE, FCC, RoHS, FIPS 140 -2 Operating Temperature ° to 50°C (320 to122°F) to 95% RED noracandensi Storage Temperature 0° to 50 °C (32° to 122 °F) 5 to 95% RH, noncondensing -20° to 70 °C ( -4° to 158 °F) Operating and Storage with Battery 10 50 °C (32° to 122 °F) -20° to 40 °C (-4° to 104 °F) Heat Dissipation 409 DT 522 BTU/hr TAR Pro 64 MB; >• STAR Pr o 125 MBA Number of personnel records with one clearance, one card /person, ten -digit cards Number of personnel records with ten clearances, one card/person, ten -digit cards 295,000 Number of personnel records with one clearance five cards/person, ten -digit cards Number of personnel records with ten clearances, five cards/person, 40 -digit cards 375,000 •• a • 110,000 • 250000 • • •••••• Notes: (a) Memory allocation within STAR Pro and STAR eX is dynamic and shared between cardholders, event storage, and configurationInnormatien. (b) To estimate how much space is needed for the personnel database in (STAR Pro v4.0 and higher and STAR eX for multiple cards &8rt' • extended card capacity, refer to the C•CURE 800/8000 v9.3 README file located in the Member Center on www.swhouse.com. • • • • (c) STAR can support up to five cards for each cardholder record; each card is independent of each cardholder in the system. • •••• • Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products Include all features. Availability varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and /or registered trademarks of other companies. 0 2009 Woo International Ltd. and its respective companies. AO rights reserved. SH0033- DS- 200908- R08-LT -EN www.swhouse.com • •• • • •• • • • •• • •••• • • •••• • •• • • ••• • • • • • • •• • • • • • • • S300-DIN-RDR2SA Two-Door Interface 0. LI 1' 1 J0 Issued Augykt 17,, Description The S300- DIN- RDR2SA module supports one or two doors. It uses standard RS-485 communications and can interface with the following controllers: • CK722 • CK721 -A • CK721 • CK720 /CK705 The S300- DIN- RDR2SA, also referred to as the RDR2S -A, provides the ability to configure supervised 4 -state inputs and unsupervised 2 -state inputs. A total of 10 inputs can be configured as supervised 4- state inputs (normally open or normally closed), or 2 -state Inputs. When in physical address mode and used with CK722 or CK721 -A version 3.0, any unused points can be configured as general purpose input/output (I/O) points, possibly eliminating the need to purchase additional I/O modules for certain installations. The RDR2S -A provides power for the card reader hardware. It does not provide power for door locking hardware. S300- DIN- RDR2SA Two -Door Interface Features • Wide range nominal voltage for power source — From +12 to 24VDC or 16 to 24VAC • Support &12S -485 bus communications at 9600 or 19200 — Autd'tf2hd rate detectiot (9600/19200 baud) Fast in,s lls tIon —IlliatuleCcan be mounted on a flat surface, DIN rail, or in a Johrlon Controls' approved enclosure. • Expandable moduegQps1 — RDR2S -A modules can be conned together via RS-485. • • • • •• Twdfgodr ai cess oontroi innput /output interface — See All • • interface signals are'do?det.Red via plug -in connectors. • • InpatYohrit (Outpufj'dnAi•D•isassociation — Reader terminal •input/b81MR (I /O) points can be re- assigned from reader - specific • • functions to genera I/O points. • All interfacce signals arg t gted via plug -in connectors. • • • • ••• • •• •••••• •••• • • • • • •••• • • 000000 • • •• • • Each of the two -door access control input/output interfaces consists of: • Wiegand DataO and Data1 interface • Supervised door monitor switch input, normally open or normally closed, based on wired configuration • Supervised auxiliary access or exit request switch Input, normally open • Supervised tamper input • Supervised spare input • Door strike relay, SPDT (Single Pole Double Thrbw) • Alarm shunt relay, SPDT • Red lamp driver (open collector) • Green lamp driver (open collector) • +12VDC 250mA reader power supply Also, the following inputs are shared by both interfabes (one per module): • Calibration resistor input • Supervised power fail Input • Supervised tamper input The following figure depicts the position of the terminal blocks. READER 2 ., To calibration resist) To power supply EADER2 READER2 READER 2 STRIKE SHUNT Settable switches Battery Low/Power Fail To 8300 bus The performance specifications are nominal and conform to acceptable Industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of Its products. ® 2010 Johnson Controls, Inc. www.iohnsoncontrols.com 1 of 3 Johnson Controls S300- DIN- RDR2SA (Continued) RDR2S -A Sample Configuration The following configuration shows a two-door configuration with the RDR2S -A interfacing with a CK721 controller. Extt Sensor Door Monitor DOOR 1 To power supply Reader RDR2S -A Strike To DOOR 2 I I CK721 E Reader and 1/0 Modes In the RDR2S -A the reader and I/O modes are enabled. LEDs The RDR2S -A module has 4 LEDs: • Power (POWER): On during normal operation. • Status (STATUS): Blinks every second when module is operational. • Transmit (MIT): Blinks when a character is transmitted to the controller's S300 bus. • Receive (RCV): Blinks when a character is received from the controller's S300 bus. Input Point Calibration Termination resistance ranges from 150 Ohm to 2000 Ohm (recommended: 1200 Ohm, 1%). To calibrate individual inputs, use a command launched from the host. Settable Switches The RDR2S -A has the following settable switches: Wiegand, End -of- Line (EOL), and address switches. Wiegand switch Wiegand Switch When using Wiegand Data0 and Data1 interfaces the Wiegand/ RS-485 switch should be on (up). End -of -Line Switches When the RDR2S -A is used at the end of the RS-485 network it must be set as a "network terminating device." EOL Address switches switches The RDR2S -A module is set as a network terminating device when switch position 2 and switch position 3 are turned on (up). The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of Its products. © 2010 Johnson Controls, Inc. www.lohnsoncontrols.com 2 of 3 Configuration Switches SW1 When using the RDR2S -A module with the CK721 -A version 3.0 and higher, switches 1 though 8 must be off. Address Switches When used with CK721 -A (versions prior to 3.0), CK721, or CK720/ CK705 controllers, positions 4 to 6 determine module address. When used with CK722 or CK721 -A (version 3.0 and higher) controllers, positions 4 to 8 determine module address. Note: Ensure that the address of the RDR2S -A does not conflict with the address of any other device on the S300 bus. Battery Low /Power Fail The RDR2S -A has an Internally derived, 2 -state input that can be used to detect battery low or power fail state. To use this feature, the "Input Terminal 1 - Spare Input 6" (CK721/ CK720 /CK705) or "Power Fail - General Purpose Input' (CK722) must be wired to a power fail monitoring circuit. The internally derived input is in alarm only if the power fail point is also in alarm and power voltage has decreased more than 10% from either 12V or 24V (the system detects 12 versus 24 nominal voltage automatically). Note: For use only with 12VDC or 24VDC battery- backed power supply. Technical Specifications Description Specification Input Power +12 to +24VDC or 16 to 24VAC at 24W Reader Interface • 2 -wire Megand (up to 256 bits) • 12VDC, 250mA (typical), 500mA (peak) • Red indicator • Green indicator General Purpose inputs Resistive load Relay Outputs 1A max. 0- 24VDCNAC, 25VA max Red LED /Green LED Outputs 50mA max. 0- 24VDC. See "Caution° below. Communications 2 or 3 -wire RS-485 Certifications FCC Part 15, Class B CE Mark C -Tick Mounting Specifications DIN rail or flat surface Dimensions 5.7 H x 5.9 Wx 2.2 D Inches 14.4 cm x 15.0 cm x 5.5 cm) Ambient Temperature 32° to 122°F (0° to 50 °C) •••• Humidity 10 to 90% non - condensing • • • • Ventilation Cabinets requireiree movement of1lr over all exposed surface* • •••••• - - • • • • IMPORTANT: The Red LED /Green is uD open collecpbr pegs}ts can be damaged with the use of altern•ntirtgooutrent (AS} • potentials as low as 1 VAC. The LED outpytt an only b... • connected to direct current (DC) loadstii /934VDC. • •••• Ordering Information •••••• • • •• Part Number Description • • • • • • • S300- DIN- RDR2SA 2-door interface, supenised Inputs, outputs, • • • ••• • • 000000 • • • • • • • • • • • • • Related Documentation S300- DIN- RDR2SA Hardware installation Manual S300- DIN- RDR2SA Address Mode Configuration Technical Bulletin CK721 -A Installation and Qperation Manual CK721 Installation and Operation Manual CK722 Hardware Installation Manual CK722 Commissioning Guide CK720 Network Controller Installation and Operation Manual CK705 Network Controller Installation and Operation Manual •••• • • • •••• • •• • • • • • • • • • • • � • • • • • • • • ••••• • • • • •••••• • • • • • •••••• •• • • • • • •• •••• • • •••• • •• • • • ••• •••• • • • • •• •• •• • • •••• • ••••• • • •• • • • ' • • The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of Its products. O 2010 Johnson Controls, Inc. www.johnsoncontrols.com 3 of 3 AMNIA CIViy AL102411LAC SC: Po 'er Sop Iy /C h ar ers ulii fUiiiiil Access ,'r Controllers Rev. DSAL1024ULACM - AO6F • The AL1024ULACM / AL1024ULACMCB converts an 115 60Hz input into eight (8) independently controlled 24VDC Fail -Safe and/ r Fail- Secure outputs with a total of 10 amp continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. These units will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail -Safe and/or Fail- Secure modes. The units are designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The 'FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. AL 1024ULACM • Eight (8) independently controlled fuse protected outputs. AL 1024ULACMCB • Eight (8) independently controlled PTC protected outputs. • Class 2 Rated power limited outputs. ec®fdtb ;nn • 24VDC @ 10 amp supply current. • Power supply input options: a) One (1) common power input for ACM8/ ACM8CB and lock power (factory installed). b) Two (2) isolated power inputs - One (1) to power the ACM8 /ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total). • Eight (8) Access Control System trigger inputs. Input options: a) Eight (8) normally open (NO) inputs. b) Eight (8) open collector inputs. c) Any combination of the above. • Eight•($l Independently controlled outputs. • .. • • • Output ntions:: . • • • .. ..., a) •l t {8) Fa!Safeand/or Fail- Secure • • b) $ight.(8) forp:t14 5 amp rated relay outputs •(AL1024UI;E4. .pn1y). c) .A iy. combinat� of the above. • • • Eight E8) auxiliacycp ver outputs (=switched) • Outptit ratings • Fuses are hated.•@ 3.5 amp (AL 1024ULACM). • • -1'PCs are Zatptl•@ 2.5 amp • . �X1+1024ULACMVICB). • Input 115VAC 60Hz rated @ 4.4 amp. • ACM8 board main fuse is rated at 10 amp. • Filtered and electronically regulated outputs (built -in power supply). • Short circuit and thermal overload protection. • Red LEDs indicate outputs are triggered (relays energized). • Fire Alarm disconnect (latching or no/k- latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally glosed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL). • Green LED indicates when FACP disconnect is triggered. • Built -in charger for sealed lead acid or gel type batteries. • AL1024ULXB (Power Supply Board) maximum charge current 3.6 amp. • Automatic switch over to stand -by battery when AC fails. • Zero voltage drop when unit switches over to battery backup (AC failure condition). • AC fail supervision (form "C" contact). • Battery fail and battery presence supervision (form "C" contact). • AC input and DC output LED indicators. • Enclosure accommodates up to two (2) 12AH batteries. Itronix® AMNIA CIViy AL102411LAC SC: Po 'er Sop Iy /C h ar ers ulii fUiiiiil Access ,'r Controllers Rev. DSAL1024ULACM - AO6F • The AL1024ULACM / AL1024ULACMCB converts an 115 60Hz input into eight (8) independently controlled 24VDC Fail -Safe and/ r Fail- Secure outputs with a total of 10 amp continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. These units will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail -Safe and/or Fail- Secure modes. The units are designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The 'FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. AL 1024ULACM • Eight (8) independently controlled fuse protected outputs. AL 1024ULACMCB • Eight (8) independently controlled PTC protected outputs. • Class 2 Rated power limited outputs. ec®fdtb ;nn • 24VDC @ 10 amp supply current. • Power supply input options: a) One (1) common power input for ACM8/ ACM8CB and lock power (factory installed). b) Two (2) isolated power inputs - One (1) to power the ACM8 /ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total). • Eight (8) Access Control System trigger inputs. Input options: a) Eight (8) normally open (NO) inputs. b) Eight (8) open collector inputs. c) Any combination of the above. • Eight•($l Independently controlled outputs. • .. • • • Output ntions:: . • • • .. ..., a) •l t {8) Fa!Safeand/or Fail- Secure • • b) $ight.(8) forp:t14 5 amp rated relay outputs •(AL1024UI;E4. .pn1y). c) .A iy. combinat� of the above. • • • Eight E8) auxiliacycp ver outputs (=switched) • Outptit ratings • Fuses are hated.•@ 3.5 amp (AL 1024ULACM). • • -1'PCs are Zatptl•@ 2.5 amp • . �X1+1024ULACMVICB). • Input 115VAC 60Hz rated @ 4.4 amp. • ACM8 board main fuse is rated at 10 amp. • Filtered and electronically regulated outputs (built -in power supply). • Short circuit and thermal overload protection. • Red LEDs indicate outputs are triggered (relays energized). • Fire Alarm disconnect (latching or no/k- latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally glosed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL). • Green LED indicates when FACP disconnect is triggered. • Built -in charger for sealed lead acid or gel type batteries. • AL1024ULXB (Power Supply Board) maximum charge current 3.6 amp. • Automatic switch over to stand -by battery when AC fails. • Zero voltage drop when unit switches over to battery backup (AC failure condition). • AC fail supervision (form "C" contact). • Battery fail and battery presence supervision (form "C" contact). • AC input and DC output LED indicators. • Enclosure accommodates up to two (2) 12AH batteries. Agency Approvals UL Listed for Access Control Systems Units (UL 294). CUL Listed - CSA Standard C22.2 No.205 -M1983 Signal Equipment. M EA MEA - NYC Department of Approved Buildings Approved. ire CSFM - California State Fire Marshal Approved. Ctffir 000000 000000 00000000000 000000000000 000000 000000000000 000000 000000 000000 1t5 Enclosure Dimensions 15.5 "H x 12 "W x 4.5 "D Sr 000000 000 0 0 0000 00000000 00000000 000000000000 000000 000000 000000 •• • • • • • • • • • • • •• •• • • ••• • • •••• • • ••••• • • • • •• • • • • • • • • • • •• • ••••• •••• •••• • • • • •••• 5555 • •• • • • • • • • • • • • • • •• • • ••• • • ••• • • iJa roui eons • • • e, www. GE- lnterlogix com Overview The GE lnterlogix 1078 Series Steel Door contacts are designed Specifically for use in the steel doors commonly found in commercial building applications. The unique housing design features a rugged unibody construction with flexible ribbed sides for quick, secure installation without gluing. The magnet housing isolates the magnet from the surrounding steel for maximum gap distances, both make and break Over seven models including: Wide Gap, SPDT, DPDT, and Biased for High Security applications Make the 1078 Series the most widely used and comprehensive line available. On available models a terminal connection (T) makes installation easier. Simply strip the wire, insert it into the terminal block and tighten. The terminal accepts any wire size from 14 to 22 gauge, and has a unique one piece design for added strength. An optional Rare Earth Magnet is available. It is designed for use in metal entry /exit doors with a channel in the top of the door. The magnet eliminates the need to cut a mounting hole in the door channel. The flexible magnet housing can be compressed to accommodate a variety of channel widths for quick, easy installation. Adhesive is recommended. Architectural and Engineering Specifications • ••• • Desi • Designee �����" forua eiD•51 • Steel Doors • • • • • The contact contains a hermetically sealed magnetic reed switch. The reed shall be potted in the contact housing with a pplyurethane based compound. Contact and magnet housing shall snap -lock into a 3/4° or 1° dia. hole. Housings shall be molded of flame retardant ABS plastic. Color of housings shall be off - white, grey or mahogany brown. The magnet shall be made of Alnico V. are Earth Magnet shall be made of neodymium iron boron. 5.555 • • •• • • • • • •• •••• • • • • • •••• • • • • • •• • • • ••• •••• • •••• • • Snap -lock insulation bushing for tight fit and maximum gap • ii Vei. • • • • B5555• eth c �ntay :and magnet plastic housings are constructed of one:g1e4 pf5thick- walled ABS plastic for maximum strength aid aftmability. • •••• • • •• • • • L' inf�onriattb Steel Door Contact 3/4 " and 1 " contacts 1078/1076 Series Optional 1840 Rare Earth Magnet Standard Features o Fly leads and tenninal options available o Designed specifically for use in steel doors o Special ribbed sides allow for easy installation o Rugged unibody construction for maximum durability and reliability o Terminal models available for easier installation o Regular, Wide Gap, SPDT, DPDT, and High Security models available o Rare Earth Magnet designed for steel door with top channel available Model numbers 1076, 1076W, 1076C, 1076CW, 1076D, 1078, 1078W, 1078C,1078CT, (R)1078, 1078CTW Dimensions Models: (8)1078, 1078W, 1076, 1076W, 1076D Models: 1078C, 1076C, 1076CW,1076CH Models: 1078CT,1076CTW, (R) prefix indicates Rare Earth Magnet L. 1.125' 286 cm 1.76' �f 3.97 c cm _I Magnet Part No. 1921 (included) I 1.563' j 375' I- 3.97 cm-1262 cm 750' 1 1.91 cm Magnet Part No. 1921 C (included) Ordering Information Dale 1076 1076W 10760 1078 1078W 1076C 1076CW 1078C (R)1078 1078CT 1078CTW 1" 4.1 1.6253 ' Imo- cm .875' 2.22 cm 1.56' 0.375' I`- 3.96 cm 0.64 cm 0.75' 1.91 cm Loo Open or Closed 1" Open or Closed 1" Open or Closed 1" Closed 1" Closed 3/4' Open or Closed 3/4° Open or Closed 3/4" Closed 1" Closed 3/4 Closed 3/4 Closed 0.938° 2.36 cm Part 9 art N 1929 (included) ,ectricaa SPOT SPDT DPDT N/0 N/O SPOT SPDT N/0 N/0 N/O N/O * Gap distances are nominal make distance ±20 %. Gap specifications are for switch to make. Break distance is approximately L1 to 1.5 times make. Specifications Form A: ( R) 1078,1078W,1078C,1078CT,1078CTW Voltage 100V AC /DC max. Current Power 0.5A max. 7.5 W max Ferro C: 1076, 1076W, 1076D, 1076C(D), 1076CW, 1076CH Voltage 30VAC/DC max. Current 0.25A max. Power 3.0 W max. Rare Earth Magnet 1 "x1.125" 1 "x1.125" 1 "x1.125" 1" x 1.125" 1" x 1.125" .75" x 1.125" .75" x 1.125" .75" x 1.125" 1" x 1.125" .75" x 1.625" .75" x 1.625" esp.; r-ed Magi 1" x 1.563" 1 "x1.563" 1" x 1.563" 1 "x1.563" 1" x 1.563° .75" x 1.563" .75" x 1.563" .75" x 1.563° 1" x 1.563" .75" x 1.56" .75" x 1.56" 1625° 4.13 cm 1.813' 4.60 cm 11 0.5° 0.625" 1.27 cm 1.59 cm Legs may be cut for Height Adjustment Protected by U.S. Patent 5,844,458. 1" 2" 3/4 1" 2" 7/8 2" 1/2 1" 7/8" 5/13 aWCe Up to 1/2° Up to 5/8 Up to 1" Up to 3/8 Up to 5/8" Up to 1/2 Up to 5/8 Up to 1" Up to 3/8 Upto5 /6 Up to 3/4° N/A Up to 1/2" Up to 5/8° 1/2 3/4 N/A •••• • 5/8 •• • • • • • • • • • • • •• •• • • •••••• •••• • • •••• • • •Interlogix • • •• • LISTED M, N, G M, N, G M, N, G M,N,G M, N, G M, N, G M, N M, N, G M, N M, N N • • • • •• •• • •••• • • •••• www.GE- Interlogix.com @2002 GE Interlogio. All trademarks are properties of their owners. C- 3617- FLG10K -0403 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800 -648 -7424 Faxback: 800 -483 -2495 2266 Second Street North North St Paul, MN 55109 Phone: 651- 777 -2690 USA & Canada: 800-777-5484 Technical Service: 800 - 777 -2624 •• • • • • • • •• ••• • •••• • • ••• • • • • • •••••• • •• • • 00000 • • • • • • • Intrusion Systems �DS160 Series I DS160 Series ugh . rrreaince Request -to- - xit Detectors The DS160 Series consists of the DS160 Detector (light gray) and the DS161 Detector (black) specifically designed for Request -to -exit (REX) applications. With features such as timers, door monitor with sounder alert, and pointable coverage, the DS160 and DS161 have the flexibility to meet the most stringent REX requirements. The exclusive Sequential Logic Input (SLI) provides added security that is not offered in any other REX device. Functions Sequential Logic Input (SLI) The SLI terminal allows connection of a second device to require sequential detection. This eliminates the possibility:Etat an object that is slid through the door or • inderrft� tit the dooi.wilhactivate the detector. This input • tan al{��yled to rot:k the sensor if motion is present • • outsidethe premise :. • poor M$gitn Th se'hSof'ggn mon:tpi door contact to allow special •••:•.controlpiVie internal gj y. For example, if the door is • •openeclimrithifi the IAA/41e period, the sensor can be • *programmed to haltetiv typer. If the door is not opened ' :••••within agpecific tirna■rteri3d, the relay can be • • programmed to deactivate. •••• • •• • • • •• •••• Invente• for life • Door monitor with sounder alert • Sequential Logic Input (SLI) • Internal vertical pointability • Wrap- around coverage pattern with precise pattern control ► Up to 64 second adjustable latch time • Selectable relay trigger mode • Selectable fall -safe or fail- secure modes • Adjustable sounder volume • Activation LED Sounder Alert An integrated sounder can be programmed to activate if the door is left open too long. The sounder volume is fully adjustable to 85 dB. Keycard Input The keycard input allows the sensor relay to be controlled from an external source, such as an access control system or card reader. www.boschsecurity.com )S 60 e _ es !g man Certifications and Approvals Region Certification eges; ® ec Europe CE 89/336/EEC, EN55022: 1998 +Al: 2000 +A2: 2003, EN50130-4: 1996 +A 1:1998 +A2: 2003, EN 61000 -4 -2: 1995 +A1: 1998 +A2: 2001, EN61000 -4 -3: 2002 +A1: 2003, EN61000-4-4: 1995 +Al: 2000 +A2: 2001, EN 61000 -4- 5:1995 +Al: 2001, EN61000-4-6: 1996 +Al: 2001 +A2: 2001, EN61000 -4- 11:1994 +Al: 2001, EN60950 -1: 2001 2004/108/EC; EN 50130- 4:1996 +A1:1998 +A2:2003; EN 60950- 1:2006 USA Europe UL ALVY: Access Control Systems Units (UL294) Complies with EN50131 -1 Grade 2 Installation /Configuration Notes OOOOOO OOOOOO CIO OO MOOOO OOOOOO Front View Mounted on wall above door and mounted on ceiling .75 m (2.5 ft) in front of the door. ors 1.5 m (5 ft) Side View The higher that you mount the unit, the larger the coverage area. Do not mount the DS160 /DS161 more than 4.6 m (15 ft) above the floor. Side view of coverage pattern with the unit mounted at 4.6 m (15 ft) above the floor with the lens pointed straight down. 3m (10 ft) • • • • .75m • • • 1.5m (2.5 ft) •••••, .(5,f')• S. • Side View The higher that you mount the it the un larger• • • • coverage area. Do not mount the pan/pawl mope than 4.6 m (15 ft) above the floor. • Side view of coverage pattern with,€be upit mowiteul al 4.6 m (15 ft) above the floor with the les poin teestraight down. • • • • • •• • • • • • • • eves reign F er orr a q6- uesL(o exit Detec or =s Coverage Information The coverage (detection area) varies depending on the mounting height above the floor, angle of the lens, and whether the unit is mounted on a wall above the door or on the ceiling. the coverage is 2.4 m x 3 m (8 ft x 10 ft) The coverage patterns for the detector at a height of 2.3 m (7.5 ft) are shown. The coverage pattern increases or decreases with height and detector alignment. Note When you mount the unit on the wall and the lens points straight down, some detection zones point toward the wall and do not detect movement. The diagrams depict views of the coverage pattern with the detector mounted at 2.3 m (7.5 ft) above the floor with the lens pdinted straight down. Zones that are pointed toward the wall are not shown. Technical Specifications Environmental Operating Temperature: -29 °C to +49 °C ( -20 °F to +120 °F) For UL Certificated installations, 0 °C to +49 °C ( +32 °F to +120°F) Radio Frequency Inter- No alarm or setup on critical frequencies in the ference (RFI) Immunity: range from 26 MHz to 1000 MHz at 50 Vim Complies with Environmental Class li (EN50130 -5) Mechanical Dimensions: Material: Modes 4.5cmx17.1cmx4.4cm (1.80 in. x 6.75 in. x 1.75 in.) High impact ABS plastic enclosure Power Loss De- Programmable fail -safe or fail-secure modes. fault: Timer: Programmable reset accumulative or non -reset counting mode. Electrical Current Draw; 8 InA nominal standby current, 39 mA at 12 VDC in • • •••• alarm , •• ••••i • Woltage: • 1? VACgr1/DC je 30 VAC or VDC • Alarm Output: • T *o Form C rel contacts each rated 1 A at 30 VAC or • • V C fa letiotid loads • indicatoe • • , 1 activedyl. • • •: • delay Latch •' Adjusttble'f?olrf0.5 sec to 64 sec. •••• •••• • Time: • • • • •••• •••• • • • • • • • •• ••• •••• • • • • •• • • • • • Ordering Information DS160 Request -to -exit Detector Light gray enclosure. For use in request -to- exit (RD() applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door monitor with sounder alert, and pointable coverage. DS160 DS161 Request -to -exit Detector Black enclosure. For use in request -to -exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door monitor with sounder alert, and pointable coverage. DS161 Accessories TP160 Trim Plate A light gray trim plate used when mounting the detector over a standard single -gang box. TP160 TP161 Trim Plate A black trim plate used when mounting the sensor over a standard single -gang box. TP161 www.boschsecurity.com S1.6Oe6es Ilgh 1' er'or,nce' Americas, Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York 14450, USA Phone: +1 800 289 0098 Fax: +1 585 223 9180 securlty.sales@us.bosch.com www.boschsecurity.us eaie Europe, Middle East, Africa, Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emeasecuritysystems@bosch.com www.boschsecurity.com @ Bosch Security Systems Inc 20101 Data subject to change without notice T11382428271 Cur. en-US, V14, 2 Dec 2010 Asia-Pacific, Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems(5bosch.com www.boschsecurlty.com •• • • • • • • • • • • • •• •• • • •••• • • •••• • •• • • • • • • ••• • • •••• • • • • • •• • • • •• • •••• • • •••• • •• • . ••• • •••• • • •••• • • • • • • • • • • ••••• • • • • • • • UL 1034 field selectable field selectable burglary listed (fail secure / fail safe) (12 or 24VDC) grade 1 • • • • • • • ••••• • • • • 3• • I 9600 Genesis •••• • •••• • • • • •• • • • • • •• •••• • • •••• • •• S. • ••• •••• • • The origi al completely surface mcunte solution ®updated! With a new enhanced design, the 9600 series Genesis IIPTM' continues to set the standard for surface mounted electric strikes. The 9600 accommodates rim exit devices in metal or wood jambs. The 9600 features an internally mounted solenoid and two stainless steel, Independently - operating locking mechanisms. The 9600 is easy to install, with all components encased in the 3A" thick stainless steel housing, requiring no cuts to the jamb prior to installation. Specifications a UL1034 burglary- resistant listed ANSI/BHMA, A156.31 Grade 1 ( #E09731, #EQ2732) • Patent # 6,390,520 • • • • • T nlapplication %44(g 11••••5 alArnical •4.41.5•Amps @ 12VDC continuous duty •� �42i Amps @ 24VDC continuous duty • • 3 www.hesinnovations.com Standard Features • Completely surface mounted ® Stainless steel construction ® Tamper resistant ® Static strength 1,500 lbs. ® Dynamic strength 70 ft -lbs. 9 Endurance 500,000 cycles ® Field selectable fail safe /fail Secure ® Dual voltage 12 or 24 VDC ® Horizontal adjustment ® Non- handed ® Internally mounted solenoid ® Accommodates up to 3/4" pullman latch ® Five year limited warranty ��, [228.6] 9" [19.1] 3/4" [44.5] 1 -3/4" Optional Features • LBM - Latchbolt monitor • LBSM - Latchbolt strike monitor Accessories • 9500/9600 108 - Spacer plate • SMB - Surface mounting box • 2001 M - Plug -in bridge rectifier • 2004M - ElectroLynx® adapter • 2005M - SMART Pac IITM • 2006M - Plug -in buzzer Finishes • 630 - Satin stainless steel finish • 605 - Bright brass finish • 606 - Satin brass finish • 612 - Satin bronze finish • 613 - Bronze toned finish • 629 - Bright stainless steel finish •• • • • • • • • • • • • •• •• • • •••••• •.•• • • •••• •••••• • •.•••• •• • • • • • • •. • • • •..• • • • • • •• • • • •• • ••.•. • •••• • •• • • ••• • •••• • • • •••••• • • •••••. • • • •••••• • • • • •••••• • • • • • • Customer Support 800.626.7590 38