RC-14-408Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
BUILDING
PERMIT APPLICATION
FBC 20
Permit No.
Master Permit No, P, /it
Permit Type: BUILDING ROOFING
JOB ADDRESS: 1130 NE 91 Terrace
City: Miami Shores County: Miami Dade zip: 33138
Folio/Parcel #: 11- 3205 - 001 -0410
Is the Building Historically Designated: Yes NO X Flood zone: Yes - AE
OWNER: Name (Fee Simple Titleholder): Barbara Ter Horst Phone#: (772) 579 -9651
Address: 1130 NE 91 Terrace
City: Miami Shores
Tenant/Lessee Name: Owner Occupied
Email: terhorstb @gmail.com
State: FL
zip: 33138
Phone#:
CONTRACTOR: Company Name: OBRA PRIMA Construction Group LLC
Address: 3408 W. 84 Street, Suite 316
Phone#: (305) 825 -2300
City: Hialeah
State: FL
Zip: 33018
Qualifier Name: Joel Ripoll phone#: (305) 825 -2300
State Certification or Registration #: CGC 1521523 Certificate of Competency #:
Contact Phone#: (305) 308 -5601 Email Address: info @obraprimacg.com
DESIGNER: Architect/Engineer: Phone#:
Value of Work for this Permit: $ 6,000.00 Square/Linear Footage of Work: 900 sq. ft.
Type of Work: ❑Addition ❑Alteration ❑New Repair/Replace ❑Demolition
Description of Work: Installation of New Drywall for Bedrooms and Dining Area with Drywall finish work.
Color thru tile:
* *** * * ** n****+ x****************** ******* Fees*******+ x******* ***** * ***** * *****************
Submittal Fee $ a,z Permit Fee $ CCF $ CO /CC $
Scanning Fee $ Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $ • 00
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 208298 Permit Number: RC- 3- 14-408
Scheduled Inspection Date: May 28, 2014
Inspector: Rodriguez, Jorge
Owner: TER HORST, BARBARA
Job Address: 1130 NE 91 Terrace
Miami Shores, FL
Project: <NONE>
Contractor: OBRA PRIMA CONSTRUCTION GROUP LLC
Permit Type: Residential Construction
Inspection Type: Final
Work Classification: Alteration
Phone Number (305)432 -1775
Parcel Number 1132050010410
Phone: (305)825 -2300
Building Department Comments
INSTALLATION OF NEW DRYWALL FOR BEDROOMS
AND DINING AREA WITH DRYWALL FINISH WORK
**PLEASE NOTE THIS IS ACTUALLY A RESIDENTIAL
CONSTRUCTION PERMIT NOT A DEMO**
Infractio Passed Comments
INSPECTOR COMMENTS
False
Inspector Comments
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
May 28, 2014
For Inspections please call: (305)762 -4949
Page 2 of 16
Bonding Company's Name (if applicable) Not Applicable
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable) Not Applicable
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved nd a r ' ' nspection fee will be charged.
Signature
I
Owner or Agent Contractor
The fore going instrument w acknowl7dged � re this The foregoing instrument was acknowlged before me thi
day of 'K , 20 , b, by & 2tWq /AL & r , day of & , 20 / V, by $LL ,w�
who is o me or who has produced who is personally known to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUB IC: NOTARY PUBL�L "
Sign:
Print:
My Commission Expire
MY COMMISSION # DD994339
EXPIRES June 14, 2014
(407) 398 -0153 FloridaNOtaryServhs•com
i
, %IN
*c MY COMMISSION # D0994339
,, EXPIRES June 14, 2014
(407 39&0153 FbrtdeNotarySerVICe•com
(44(444—p4-1.+*******************************
** * *Hr HaHasp**rk +Nsprkgsrk,k **rkrk$tgYjNsk*** *sk$ **** ***4tHrHr*=k*rk,k,k**** * * * ** $*skskgasN***
APPROVED BY
Plans Examiner
Structural Review
(Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09)
Zoning
Clerk
I
System: AC WEST
Location: Miami, Florida
Prepared by: Marcos Misrahl PE
sys
COPY
TABLE 1. SIZING DATA (COOLING)
Block Load 3.05
March 04, 2014
Page: 1
Total Coil Load 25,201 BTU/hr Load Occurs
Sensible Coil Load 23,793 BTU/hr Outdoor Db/Wb
Total Zone Sensible 23,348 BTU/hr Coil Conditions:
Supply Temperature 57.0 F Entering Db/Wb 75.0/63.2 F
Supply Air (Actual) 1,201 CFM Leaving Db/Wb 56.7/56.1 F
Supply Air (Standard) 1,201 CFM Apparatus Dewpolnt 55.7 F
Ventilation Mr 0 CFM Bypass Factor 0.050
Direct Exhaust Air 0 CFM Resulting Zone RH 52.4 %
Reheat Required 0 BTU/hr
July 17:00
90.5/77.6 F
Total Coil Load 2.10 Ton
Floor Area 855 sqft Sensible Coll Load 1.98 Ton
Overall U -Value 0.175 BTU/hr/sgft/F SQFT/Ton 407.13
Vent Mr 0.00 CFM/sqft Cooling 29.47
Vent Air 0.00 CFM/Person Coolire 1.41
TABLE 2. SIZING DATA (HEATING)
Heating Coil Load
Ventilation Load
Total Zone Load
Ventilation Airflow
Supply Airflow
9,262 BTU/hr
0 BTU/hr
9,262 BTU/hr
0 CFM
1,201 CFM
Heating
Heating
Floor Area
Overall U -Value
Vent Mr
Vent Air
I
10.83 BTUPor /sgft
1.41 CFM/sqft
855 sqft
0.175
0.00 CFM/sqft
0.00 CFM/Person
TABLE 3. INPUT DATA (WEATHER)
Location Miami, Florida
Data Source User Defined
Latitude 25.8 Degree
Elevation 7.0 ft
Atmasoheric Clearness 0 0.90
TABLE 4. INPUT (HVAC SYSTEM)
System Name AC WEST
System Type Clg and Warm Air Ht Cooling (Occ.) 75.0 F
System Start 6:00 Cooing (Unocc.) 75.0 F
Duration 24 brs Heating 70.0 F
SIZING SPECIFICATIONS RETURN AIR PLENUM No
Supply 57.0 F FAN
Ventilation 0.00 CFM/person Configuration Draw -Thru
Exhaust 0.00 CFM Static Pressure 0.50 in. wg.
Summer Dry -Bulb
Coincident Wet-Bulb
Daily Range
Winter Dry -Bulb
92.0 F
78.0 F
15.0 F
43.0 F
THERMOSTAT SETPOINTS
I
FACTORS
Coil Bypass 0.050
Safety (Sens) 10 %
Safety (Latent) 10 %
Heating Safety 0 %
TABLE S. TOP TEN COOLING COIL LOADS
Time Sensible Ton Total Ton
Time Sensible Ton Total Ton
1) July 17:00 1.98 2.10 6) July 18:00 1.93 2.04
2) August 17:00 1.97 2.08 7) June 18:00 1.92 211;_
3) June 17:00 1.96 2.08 8) June 16:00 1.91
4) July 16:00 1.94 2.05 9) May 17:00 1.91
5) August 16:00 1.93 2.05 10) September 17:00 1.88
1
SYSTEM SIZING SUMMARY
System: AC WEST
Location: Miami, Florida
Prepared by: Marcos Misrahi PE
Block Load 3.05
March 04, 2014
Page: 2
Zone Name
AC WEST
Max. Cooling Design Airflow
Max. Heating Design Flow
Sensible Rate Load Rate
(BTU/hr) (CFM) Design Time (BTU/hr) (CFM)
23,348 1,201 July 17:00 9,262 -
Total: 1,201 Total: .00
SYSTEM SIZING SUMMARY
System: AC EAST
Location: Miami, Florida
Prepared by: Marcos Misrabi PE
Block Load 3.05
March 04, 2014
Page: 1
TABLE 1. SIZING DATA (COOLING)
Total Coil Load
Sensible Coil Load
Total Zone Sensible
Supply Temperature
Supply Air (Actual)
Supply Air (Standard)
Ventilation Air
Direct Exhaust Jr A
Reheat Required
43,238 BTU/br
42,050 BTU/hr
41,263 BTU/hr
57.0 F
2,123 CFM
2,123 CFM
0CFM
o CFM
0 BTU/hr
Load Occurs
Outdoor Db/Wb
Coil Coadtlons:
Entering Db/Wb
Leaving Db/VVb
Apparatus Dewpoint
Bypass Factor
Resulting Zone RH
June 17:00
89.5111.6 F
75.0/63.0 F
56.7/56.1 F
55.7 F
0.050
51.7 %
Total Coil Load 3.60 Ton
Floor Area 1,462 sqft Sensible Coil Load 3.50 Ton
Overall U -Value 0.211 BTU/hrlsgWF SQFT/Ton 405.76
Vent Air 0.00 CFM/sqft Cooling 29.57 BTU/hr/sgft
Vent Air 000 CFM/Person Cnolno 1.4S CFMh nft
TABLE 2. SIZING DATA (HEATING)
Heating Coil Load
Ventilation Load
Total Zone Load
Ventilation Airflow
Supply Airflow
14,938 BTU/hr
o BTU/hr
14,938 BTU/hr
0 CFM
2,123 CFM
Heating
Floor Area
Overall U -Value
Vent Air
Vent Mr
10.22 BTU/hr/sqft
1.45 CFM/sqft
1,462
0.211
0.00 CFM/sqft
0.00 CFM/Person
TABLE 3. INPUT DATA (WEATHER)
Location Miami, Florida
Data Source User Defined
Latitude 25.8 Degree
Elevation 7.0 ft
Atmospheric Clearness # 0.90
TABLE 4. INPUT (HVAC SYSTEM)
Summer Dry -Bulb
Coincident Wet -Bulb
Daily Range
Winter Dry -Bulb
92.0 F
78.0 F
15.0 F
43.0 F
System Name
System Type
System Start
Duration
SIZING SPECIFICATIONS
Supply
Ventilation
Exhaust
FACTORS
Coil Bypass
Safety (Sens)
Safety (Latent)
Heating Safety
AC EAST
Clg and Warm Air Ht Cooling (Oec.) 75.0 F
6:00 Cooling (Unocc.) 75.0 F
24 hrs Heating 70.0 F
RETURN AIR PLENUM No
57.0 F FAN
0.00 CFM/person Configuration Draw -Thru
0.00 CFM Static Pressure
THERMOSTAT SETPOINTS
0.050
10 %
10 %
0 %
0.50 in. wg.
TABLE S. TOP TEN COOLING COIL LOADS
Time
1) June 17 :00
2) June 16:00
3) July 16:00
4) July 17:00
5) July 15:00
Sensible Ton Total Ton
3.50 3.60
149 3.59
146 3.56
3.45 3.55
3.42 3.52
Time
6) Jane 15:00
7) August 15:00
8) July 14:00
9) August 14:00
1d) August 16:00
Sensible Ton Total Ton
3.42 3.52
3.38 3.48
3.36 3.46
3.35 3.45
3.33 3.43
SYSTEM SIZING SUMMARY
System: AC EAST
Location: Miami, Florida
Prepared by: Marcos Misrahi PE
Block Load 3.05
March 04, 2014
Page: 2
TABLE 6. ZONE SIZING DATA
Zone Name
AC EAST
Max. Cooling
Sensible
(BTU/hr)
41,263
Total:
Design Airflow
Rate
(CFM)
2,123
2,123
Design Time
June 17:00
Max. Heating Design Flow
Load Rate
(BTU/hr) (C)
14,938
Total: .00