Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-14-211
BUILDING PERMIT APPLIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type JOB ADDRESS: 1037 NE 91 TERRACE City: Miami Shores Folio/Parcel #: 11- 3205 - 001 -0050 Is the Building Historically Designated: Yes REX", / 'i,I I Ii i MAY 122 14 FBC 20 VD Permit No. r Permit No. RC -2 -14 -211 County: Miami Dade Zip: 33138 OWNER: Name (Fee Simple Titleholder): LANCE HARKE Address: 1037 NE 91 TERRACE NO Flood Zone: Phone#: 305 - 502 -8273 city: MIAMI SHORES state: FLORIDA Zip: 33138 I enant/Lessee Name: Phone#: Email: LHARKE @HARKECLASBY.COM CONTRACTOR: Company Name: Solar Direct Address: 6935 15th Street East Ste.120 City: Sarasota Qualifier Name: Kirk A. Muast Phone#: 941 - 359 -8228 State: FL Zip: 34243 Phone #: 941- 359 -8228 State Certification or Registration #: CVC56728 Certificate of Competency #: Contact Phone#: 941- 359 -8228 Email Address: Permitting @solardirect.com DESIGNER: Architect/Engineer: DAVE STEVENS PE34624 Phone#: 239 -671 -9210 Value of Work for this Permit: $ 27,950.53 Square/Linear Footage of Work: Type of Work: CI Address DAlteration New DRepair/Replace ODemolition Description of Work: REVISION: INSTALLATION OF ROOF MOUNTED SOLAR PV SYSTEM Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 209963 Permit Number: RC -2 -14 -211 Scheduled Inspection Date: June 13, 2014 Inspector: Devaney, Michael Owner: HARKE, LANCE AND ALLISON Job Address: 1037 NE 91 Terrace Miami Shores, FL Project <NONE> Contractor: SOLAR DIRECT INC. Permit Type: Residential Construction Inspection Type: Rough Work Classification: Solar Phone Number (305)528 -5870 Parcel Number 1132050010050 Phone: (941)359 -8228 Building Department Comments INSTALL ROOF MOUNTED SOLAR Photo voltaic SYSTEM Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 209614. CREATED AS REINSPECTION FOR INSP- 209574. Grounding of solar rails is o. k.. FiL June 12, 2014 For Inspections please call: (305)762 -4949 Page 4 of 13 r Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose properly is subject to attachment. Also, a certified copy of the recorded notice of commen t ". nt must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In I e ab ice of such posted notice, the inspection will not be approved and a reinsperction fee will be charged. Signature caner o Agent The foregoing instrument was acknowledged before me this Z.44: day of , 20 , by 1-4„ �e A • Make , who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: 4f 05 My Commission E * * * * * * * * * * * * ** APPROVED BY EUGENIO GONZALEZ Notary Public - State of Florida Q My Comm. Expires May 26, 2015 -44 7,1.t �` Commission # EE 97746 , Signature Contractor The foregoing instrument was acknowledged before me this 5411 day oft (,li , 20 j i , by Li rk Ala.r IkAGtof who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: , ilQl.€ -7Yi. Print: 1)0/w. ,(4a.rkh t vrl My Commission DONNA MY COMMISSION # EE 035709 EXPIRES: October 19, 2014 r44.0F Fe. Bonded Thu Budget Notary Services Plans Examiner Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09) April 25, Z04 Chad Godwin Solar Direct Sarasota, Florida A - Miami Shores Village APPROVED BY DATE ZONING DEPT �J= BLDG DEPT r o /tg / SUBJECT TO COMPLIANCE WITH ALL ;TATS AND COUNTY RULES AND REGULATIONS FEDERAL Re: Wakaflex Universal Flashing with Solar Mounting Application ROOFING As per the NOA # 08- 1106.03, the Wakaflex flashing is designed to comply with the Florida Building Code and the High Velocity Hurricane Zone ( HVHZ ) Wakaftex flashing may be used on any part of the roof and can be used as an additional flashing to aid in sealing and waterproofing varying components in the roof system. As shown in Fig. 1, the Wakaflex flashing can be applied over solar mounting hardware in tile roof applications and adhered to metal supports and to the Modified Bitumen surface of the roofing underlayment. In addition to the butyl strips contained within the Wakaflex flashing, asphaltic primer or Modified trowel grade mastic may be required to facilitate adequate bonding between the Wakaflex base and the other roof components. Installation: install the solar mounting brackets and waterproof as per solar panel manufacturers instructions. Where lag bolts penetrate the roofing underlayment, apply a Wakafiex target patch over mounting base/cladding. Cut Wakaflex where necessary to allow tight bond to all surfaces and where necessary, use a small roller to aid in adhesion. •••• • %Incerety ,. • • .. • • • •••• • •••• • • •• •• • . • ....Adrian roger Technira .S l iices Boral Robes HEMP' ..,F*1� ry HARK I BIDJE NCE. HARDWAR .AYOU f WI]H WAKAi.l_.I•X r t.AV.:I1INC; SOLAR IN MODUI,..E SOLAR RAIL. CO ,,r aOL.AN MOUNTING LRAGKE:T -- {3ARREL TILE .�. -WAKAFLF.> FLASHING NOA 12-0308.08 L0.1.1.1.611.3.111.31 eateb 0930.113119.1.101, One 1 DETAIL A OL)IF IED [)IT . r ROOF DE0KING w ROOF. "I RU atn.w •Ig o • • • ••• eil • • • • • • • •• • .... a ' • DETAIL B •:• : •• .• • • • -... • •••••• • • . -•• •.. • • • ••• • • MEI ilk SOLAR PV MODULE SOLAR RAIL OLAR MOUNTING BRACKET ARREL TILE a NAKAFLEX FLASHING NOA 12 0308.08 •••• •-: DETAJFL A • • •••• • •••• • .... • • •..• • • • • • ODIFIED BIT OOF DECKING 0 i OOF TRUSS DETAIL B • • • .. • • ..• • • .. .. • • Fie 1.�..Wakaflez Universal Flashing with Solar Mounting Application Details COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Monier Lifetlle LLC 200 Story Road Lake Wales, FL. 33853 MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Wakaflex Flashing LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami-Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an entitlement of any product, for sales, advertising or any other purposes shall automatically terminate 'tlus'NOA. F&i I to comply with any section of this NOA shall be cause for termination and removal of ADVERTI §EiT: The NOA number preceded by the words Miami -Dade County, Florida, and fot*Wed byt110,ekpiration date may be displayed in advertising literature. If any portion of the NOA is 'd'r'splayed, th'ea r#'sfiall be done in its entirety. ifligicirieffA'copy of this entire NOA shall be provided to the user by the manufacturer or its distributors aad'sfi ii be available for inspection at the job site at the request of the Building Official. '1'isi4OA csnsisfs.of pages 1 through 2. e. Itlmrittat documentation was reviewed by Alex Tigera. NOA No.: 08-1106.03 Expiration Date: 09 /02/14 Approval Date: 09 /02/09 Page 1 of 2 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub - Category: Flashing Materials: PIB TRADE NAMES OF PRODUCTS MANUFACTURED Test Product Dimensions Specifications Waka flex Flashing 11" x 33' ASTM D5019 22 lbs/roll 22" x 16.4' 271bs/roll EVIDENCE SUBmir EED: Test Agency PRI Construction Materials Fenestration Testing Laboratory Fenestration Testing Laboratory OR. LABELED BY APPLICANT: Product Description Lead free flashing material made of polyisobutylene membrane with aluminum webbing and butyl adhesive edges. Test Identifier Test Name/Report ASTM G 155 /G26 MLT- 007 -02-01 ASTM D 1970 09 -1633 ASTM D 412 09 -0622 APPLICATION SPECIFICATIONS: Surfaces: Concrete Tile, Wood, Clay Tile, Stucco, Steel. Date 10/21/08 06/29/09 06/29/09 Preparations: The surface shall be clean, sound and dry prior to application. All surface preparation shall be in compliance with the manufacturer's published application instructions and current Miami -Dade County Product Control Notice of Acceptance. Maximum Design N/A Pressure: GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. All bonding surfaces shall be clean, dry and free from sharp or uneven edges. .3...All work shall be performed by a Dade County licensed roofing contractor. Contractor shall be •. •: famifiripit the details and specifications published by the manufacturer. ...4.:A11 fla'shinjs must be in compliance with Roof Assembly current Product Control Notice of • •AcceRtiggs gnd applicable Building Code. • • • S. �emembranes soor packaging a shall bear the imprint or identifiable marking of the manufacturer's • gb following statement "Miami -Dade County Product Control Approved" or hhe Mj f -t3ade County Product Control Seal as shown below. • • •••• • • •• • • • •0• • 0000 • • •. • • • APPROVED; ••• END OF THIS ACCEPTANCE i APPROVED; NOA No.: 08-1106.03 Expiration Date: 09/02/14 Approval Date: 09 /02/09 Page 2 of 2 BORAL ROOFING Build something great" BORAL • • • • •• •••• • •••• • • • • • •• • • • • • • • • • • •••• •• •• • • • WEATHER EASY SAVE RESISTANT INSTALLATION TIME & MONE1 GREEN • • • r. ntversal flashiri for almost any part of the roof a Chemically seals to itself without heat, adhesives or tools • • CMI:inishetixipptrance and paintable • Easy to shape and form to complex surfaces • • • Heavy duty UWrrietent material • Butyl adhesive edges seal to concrete, clay or metal • • ToQ•tG4ic alteter/tNno lead • ••• • • •• • • • • •••• • • •••• www.boralroofcomponents.com Wakaflex® THE PREMIER CHOICE FOR ALL ROOF FLASHING NEEDS • • • up to 15% up to stretch in width 50% stretch in length FEATURE & BENEFITS WEATHER RESISTANT Weather Resistant Two heavy duty layers of Polyisobutylene (PIB) make Wakafkex" a tough, yet flexible flashing material resistant to UV, rain and snow. Its self- welding ability makes Wakaflex^ extremely resistant to long term high temperatures, heavy rain and high winds. Easy Installation Anywhere Extremely flexible and stretches easily in both INSIALIATION EASf directions. No prefabrication or welding. No adhesives, mortar or mastic needed. Simply cut •the material to the size needed, shape and install •• • • • SAYE TIME 8 M•NN • • • • • • • • • • • • • •• right on tt of. • •••• • •••• • • • • • •• •• • • • •••• • • • • •••• GREEN Wakaflex is the lead -free solution to flash all critical areas of the roof. Lead is the most common flashing material used still to this day. The Occupational Health and Safety Administration (OSHA) declared that "lead adversely affects numerous body systems and causes forms of health impairment and disease which arise after periods of exposure as short as days or as long as several years ." Any place lead is used on a tile roof, Wakaflex works better and more safely. 'According to U.S Department of Labor - OSHA: Substance Data Sheet for Occupational Exposure to Lead - 1926.62 App A, Section II Health Hazard Data, Part B. NOTF:.• This pro.iuoid••s not have an express warranty. In addition, SELLER MAKES NO EXPRESS OR IMPLIED • • • • •W •J ARRANTIEEF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE regarding this product. • • • • • • •••• APPLICATIONS • Pitch Transitions "- linger,. Chimneys & Skylights Saddle Valley Junctures Side Wall • • • •• • • • • • • • • • •` • •••. • •••• • • • • • • • ••• • •• • • • • • • • • • S. •• •••• • • •••• • WAKAFLEX CAN ALSO BE USED FOR: • Sidewalls • Splayed Gables • Hip & Ridge Junctures • Solar Panels • Chimneys • Tricky details that require weather protection • Variety of repair applications • Sew how easy Wakaflex" is to install in our video at www.boralroofcomponents.com. • • • • • b©ral ctfcor ponents.cam Apron CERTIFICATIONS / APPROVALS SPECIFICATIONS Miami Dade NOA 08- 1106.03 PART NUMBERS 90912 Wakaflexa 11"x 33'- Black 91216 Wakaflexo 22 "x 16.5'- Black Roll size Roll weight Rolls per box 11 "x33' 22 Ihs /Roll 2 Rolls 22 "x 16.5' 27 Ihs /Roll 2 Rolls ABOUT BORAL ROOFING Boral Roofing is a subsidiary of Boral USA and is the country's largest premium provider of complete roofing and re- roofing solutions for architects as well as commercial and residential builders. Boral Roofing operates 14, clay and concrete tile manufacturing plants throughout the U.S. ABOUT BORAL USA Headquartered in Roswell, Georgia, Boral USA through its subsidiaries employs approximately 1.500 individuals at more than 140 operating and distribution sites across the United States. The U.S. operations include the country's largest brick manufacturer and the largest clay and concrete roof tile manufacturer. Build something great' with Bora!' Roof Tiles i Roof Accessories i Bricks i Trim ( Stone www.boralna.com • Corporate Office Boral Roofing Products 200 Mansell Court East, Suite 310 Roswell, GA 30076 Sales Offices Phoenix, ARIZONA Corona, CALIFORNIA Gilroy, CAI IFORNIA Lathrop, CALIFORNIA Stockton, CALIFORNIA •••• • • •••• • • • • • • • Western Office Customer Service Bora! Roofing Products 800 669 TILE (8453) 7575 Irvine Center Drive, Ste. #100 Irvine, CA 92618 Rialto, CALIFORNIA Denver, COLORADO Lake Wales; FLORIDA Pompano Beach, FLORIDA Atlanta, GEORGIA • •• • • • • • • • • • • •• www.botalroofcdMi5biients.com •••• •• •• • • • •••• ••• Download a 01K41 C@ de a • • ea pp to• » • rea er • smartphone• 4 ieice a Qtloto to vis j greigisite. • • • •••• • •••• • D • ••• • •••• • • 0 BORAL • •• • • • • • The Boral Logo is a trademark of Boral Limited or its affiliates and may be registered in many jurisdictions worldwide. Kapolei, HAWAII Kansas City, MISSOURI Henderson, NEVADA Katy, TEXAS Tacoma, WASHINGTON TILE ROOFING 4i I N S T I T U T E MEM • 02013 Boral Roofing LLC AC534 6/13 &?kl.‘ .. Miami Shores Village . �' � � Building Department 7 y " \ - 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 wI INSPECTION'S PHONE NUMBER: (305) 762.4949 suu, 6)0\ `i PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 1037 NE 91 TERRACE R F C EIVED FEB 0 4 2014 FBC 20 i) Permit No. Master Perm�ttN�`I' ro. ' " — 21- 1-• ROOFING City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel #: 11- 3205 - 001 -0050 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): Lance Harke Phone#: 305 -502 -8273 Address:1037 NE 91 Terrace City: Miami Shores state: Florida Zip: 33138 Tenant/Lessee Name: Phone#: Email: lharke @harkeclasby.com CONTRACTOR: Company Name: Solar Direct Address: 6935 15th Street East Ste120 City: Sarasota State: FL Qualifier Name: Kirk A. Maust Phone #: 941- 359 -8228 zip: 34243 Phone#: 941 -359 -8228 State Certification or Registration #: CVC56728 Certificate of Competency #: Contact Phone#: 941- 359 -8228 Email Address: Permitting @solardirect.com DESIGNER: Architect/Engineer: Dave Stevens PE34624 Phone #: 239- 671 -9210 Value of Work for this Permit: $ .2 3 2 C) e 2- Square/Linear Footage of Work: Type of Work: OAddition OAlteration Description of Work: Installation of roof mounted ONew ORepair/Replace ODemolition Color thru tile: * * * * * * * * ** *+x****** ******* ** ***** ****a Fees************* **** * * ***** *** * * * * *m**** ******* Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FLRCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In th of such posted notice, the inspection will not be approved! nd a r ' e will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this 3I It day of I, r i l ', 20 i4, by tD V 1CZ t t ccri[t. who is p rsonally known me or who has produced As identification and who did take an oath. NOTARY Sign: Print: 'u- °— • ` J My Commission Expires: or The foregoing instrument was acknowledged before me this cIM day of t'14.4 ` Qr` ,20ILi,by KirIL Alan who is personally known to me or who has produced nik-S as identification and who did take an oath. NOTARY PUBLIC: Sign: /('x 4.4— 1A-- Print: POI/VA— Ma Ia r /th p�1 My Commission Rf:f PUk'c DONNA MY COMMISSION 9 EE 035709 EXPIRES: October 19, 2014 43. 44 of) Bonded Tine Budget Notary Services * * * * * * * * * * * * * * * * * * * * * * * ** APPROVED BY ft Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06/10/2009)(Revised 3/15/09) Clerk 3114 Aake r Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756,8972 CONTRACTORS' REGISTRATION FORM ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED OR THE VILLAGE MAY MAINTAIN A FILE WITH YOUR INFORMATION FOR A $30.00 FEE PER YEAR. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. X COPY OF QUALIFIER'S STATE LIC CARD B. X _ COPY OF LOCAL BUSINESS TAX RECEIPT C. X COPY OF LIABILITY INSURANCE (CERTIFICATE HOLDER TO BE MIAMI SHORES VILLAGE BLDG DEPT( D. X COPY OF WORKERS COMPENSATION ( iTHER CERTIFICATE OR EXCEPTION) IF CONTRACTOR HAS A MIAMI DADS COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT C. COPY OF LIABILITY INSURACE (CERTIFICATE HOLDER MUST BE MIAMI SHORES VILLAGE BLDG DEPT), D. COPY OF WORKER COMP. INSURANCE (EITHER CERTIFICATE OR EXEMPTION) YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE HOLDER AS FOLLOW: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 COMPLETE CONTRACTOR'S INFORMATION BUSINESS NAME: Solar Direct, Inc. BUSINESS ADDRESS: 6935 15th St. E. Ste 120 cm, Sarasota STATE FL ZIP CODE 34243 BUSINESS PHONE: ( 941 ) 359'8228 FAX NUMBER ( 941 ) 359'3848 CELL PHONE ( ) N/A QUALIFIER'S NAME: Jeffrey R. Voss QUALIFIER'S LIC NUMBER: ECI 3002053 E-MAIL ADDRESS (IF APPLICABLE): Permitting ©soiardirect.com Created on 3119109 BY MLDV1 RV 3128109 MLDV s • STATE OF FLORIDA sErAsTmENT or &WNW AND .PROFBOBOBAL loadt(LAT1O4 • grAggiomagsvisr Lipman= BOARP TALLAWSIng. L 12399-0783 MUST, sI souk* Dna 6936 lsts STREET Hy SUITE 124:f SAIMSOTX FL 34237 Ocogratulationat With Vs Ocona e. you become one of Ma neatly one million FliSrfdlatis licented. by the; Depadroant of Business.and Professional Regulation. Our profetisionalo anti businesses range from euthitetis to yacht brokers, fitilti bosom to barhegue restaurants, and.they keep Flbrida's.aconorey strong Every day we woo( to improve The vrayi.ve do bUsiniess in order to serve you bUej For Information about our services* please log onto vnevianytioridalicense.cont. There you, can fiud pore information about our divisions, and 'the ragulatlimethat impact you, sub:writ:tete department newslettets and loam moreaboutthe Department's initiatives. Our mission eit th0 gaimtmerit,is: License efficiently, Reguleite.Fairly. We. constantly strive to serve you better so that you can serve yOur oust:Isere, Thank you for doing business in ,Florida, and congratulations on your new licenser! tEkOHHRE • TM:, DOCUME;q1-1-;tS S-1Ar.s.sciFIG■JF.D; t's•11Cr?C.PPE.NrIsir.; NE;v1AP,K" PA] ENTPe3 PAPFC:I• • •• • • (Am.) 481-1395' • 12/5/13 ' Sarasota CounlyTacCallector r 2013 -14 Business Type: Business Address: MAUST KIRK Sarasota County Business Tax Receipt THIS TAX DOES NOT ASSURE QUALITY OF WORK OR CONFIRM THAT REGULATORY OR Account No. ZONING REQUIREMENTS HAVE BEEN MET. IT IS THE OWNER'S RESPONSIBILITY TO 2301100029801 ENSURE COMPLIANCE. CONTRACTOR - LICENSED SOLAR DIRECT 6935 E 16TH ST OUT -OF - COUNTY FL 34243 FL LIC CVC56728 & EC13002053 893515TH ST E STE 120 SARASOTA FL 34243 All businesses In Sarasota County are responsible for complying with the Sarasota County mandatory recycling ordinance. Valid until 9/3012014 PAID: 5537463.0001 8/5/2013 511.81 Sarasota County Tax Collector Barbara Ford4;oatos 101 S. Washington Blvd., Sarasota, FL 34236 (841) 8818300, option 3 www.SarasotTaxCofector.00m Infolt3arasotaTaxColleotor.com illa /C:/Us sl donna .SOLARDIRECT /Docurnsras/Sa1es Manager - Robert E rI rd ftles/Scuatined Boa Bocisnonts/Busirress tax receipt 20132014 usehirn 1/1 • cy?°r CERTIFICATE OF LIABILITY INSURANCE, ;ZOD 3 ". THIS CERTIFICATE it ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITIJIE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the militants holder is an ADDITIONAL INSURED, the the terms and conditions of the policy, certain policies may require an endoisetnent. certificate holder in lieu of such endoraeament(s). polioy(iea) must be endorsed. If SUBROGATION IS WAIVED, subject to A statement an this certificate does not confer rights to the _ CA INE/ Selena Watkins _ PRODUCER Ben Brown insurance Agency 3731 S Tuttle Ave Sarasota FL 34239 -6410 mg?, .,. (941) 366 -9373 I iA c Not: 041)MS -3143 ADLrRESSt salenagbenbrawnine , aom INauRER(S) AFFORDING COVERAG$ NATO A cisme A National Trust his Co 20141 INWARD Solar Direct Inc 6935 15th St E #120 Sarasota B'L 34243 -7202 INjmamFCCI Commercial Ins Co 33472 IgERe: 10/1/2014 INSURER 0: i 1,000,000 INEUREAI L:: Di1s14E TO RENTED PR 7 - tEa oclaurenc,a) sigma Ft COVERAGES CERTIFICATE NUMB ER:13 / Gt. , BA, Mob • THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY 13E ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND OONDrTIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID t': TYPE OF INSURANCE POLICY NURSER (N CCYYLAIIM�MS. (NAIUfOD1YYYY1 LIMITS . A GENERAL LIABILITY coemERCIAI. GENERAL LIABILITY • 5L0009290 -5 7.0/1/2013 10/1/2014 EACH OCCURRENCE i 1,000,000 X Di1s14E TO RENTED PR 7 - tEa oclaurenc,a) 100 ' 0 00 $ , I CLAIMS -MADE ri OCCUR am E><P (Any one person) $ 5, 000 PE9$ONAL &ADV INJURY s 1, 000, 000 GENERAL AGGREGATE $ 2,000,000 GEN 'LAGGRE�GAATEUM:T/+PPU^E�SPat —1 I I LAC PRODUCTS- COMP/OPAGG $ 2,000 ;000 X POLICY I L& $ B AUTOMOBILE LIABILITY ANY AUTO Au-OwNEo Nam AUTOS soNgoI u ED SOS M0014522-5 10/1/2013 10/1/2014 i , sa • . tt , r 1 g • i S 1,00q.000 X BODILY INJURY (Fer pavan) $ BODILY INJURY {Per 6.0c gnt $ x S Mar llD $ $ B X UMBRELLA LIAR RECESS LIAR 7i i OIXYiR CWMB MADE 10,004 _ 00009613 -5 10/1/2013 10/1/2014 EACH OCCURRENCE EMI O $ 1,000,000 • 11""11 AGGREGATE $ 1,000,000 MD TX I, ,ON $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIE.TOR(PARTNEWEXEOUmNE (� EXCLUDED', [J Sm. DESDRIP1'ION OPERATIONS below N/A • I wo SrATt/. 1 10/H- TORY Laws ) R •�� E.L EACH ACCIDENT 3 E.L. DISEASE - EA EMPLOY �= $ EL, DISEASE .. POLICY LIMIT $ • DESCRIPTION OF OPERATIOND / 1- COA'IONB / VEHICLES (Atmoh ACORD 401, ACditIons Remwl:s Sohada)a• U nmrespece le regW,ee Solar Ilnergy Contractor. • #rr.YYBa Al.... ■.w. w n - 4 ON (305)756 -8972 Miami shores Village Attn: Building Dept 10050 NE 2nd Avenue Miami Shores, FL 33138 ACORD 25 (2010/05) 1N80251201000.01 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Evan Nroirn /SALFIN► Eteablye.d. 102.., 61988 -2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD CERTIFICATE OF LIABILITY INSU � • , W' r$•U�Ir a :0 ' 1V /W C ' I1t,A�•`• G ' ' CAT CfUUOAl 103FJR. .b6 1*Y . 1x ' . .T.Widb A �'6Y "IHF- l W • ' *•, CE i 0TC A. I N �: (.� � 1 RENi' 1 E • E. 1 CA cg oStateksitkiirnrry ' 12/5/2013 �:ta ma and tru f Ol a o?The pb&yy f ntin palfciea- redo'a9i•ed3bia i�f: >:�1'stgi4 ..' t4 is,' eab ilt c I ltd tlse awl* t lgllEU • •. 4,. integrity Risk Management, Inc. 3626 Tamiaml Trail Part Charlotte, FL 33952 Phone (941) 766-1411 Fax (941) 766 -1084 . integrity Employee Leasing, Inc. . 3626 Tamlami Trail Port Charlotte, Florida 33952 • Phone (94.1) 625 -0623 Fax (941.)25-0123 Col/014m .0ERTIP.MA M ',041*f_ ehtiGaetav . sir, .: Guarantee lnsurance.drirpany. as: rtkiEF- 2300 • o ` • vofs Excc 0 Tgemp r rol4T i�"PG pissve �eaAY U.S . fu94rlOthhN, btolls JD Clr13'� wort tYP� OP , , . „71 .� i htl�ovvtiAvb• tip ro ','ED' BY.'. 1• :�.T • , ' tigi.HAVElifettl - + -i. : etg a « F gyp .-,i: ia �11T i» N . +►gD TOKIliE PcU UCY PE - tig '6* i , -- - ...+ p i _ a m . 4� &i.UIdY $ �y LI1.NGiQREztit * 0 .1' 0 ''ii 'J'" I • t • .. �,. {�ww•ro4�IBYINae/rMPd!.� (.,,` M1 4 s . REIM aµp�p 0Va jjam�� ••..``.� .0:`,90t.., "ksu'.. . .. yw . ' 10/011/14 Pi\1'{ . .. n• • �z:t1 �� A •• -., 'f + t ' ' g f" ' GPE0546000001 -113 tboboh/12 • EL s 1 000 r $` 1 OnY 6/0.00 • �ii x Employers liability H Workers' Compensation coverage Is Solar Direct, Inc., 6935 15th Street E. FAX: 941-359-3848 for - Ste eased 120 employees of but not subcontractors of: - Sarasota, FL 34243 Miami Shores Vil a Building Department 10050 N.E. 2nd Avenue Miami Shares, Florida 33138 Fax: 305-756-8972 5958 D I R E C T March 10, 2014 Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores Village, FL 33138 Re: Letter of Evidence - Permit #RC -2 -14 -211 Attn: David Dacquisto This letter is to verify that there is no other location viable for the PV modules that are to be installed on the South Facing roof. Installing the modules on the North facing roof would result in a 28% loss In production. See attached production calculations for North And South Roofs. Project Contacts: Project Engineer: Chad Godwin , (941) 359- 8228,Ext 110 Project Manager: Balazs Csakany, (941) 359 -8228, Ext 803 Project Coordinator: Frank Heddings, (941) 359 -8228, Ext 199 Job Information: Harke Residence 1037 91st Terrace Miami Shores, FL 33138 Design Firm: Solar D irect, CA29457 Chad Godwin, Project Engineer 6935 15th Street East, Suite 120 Sarasota, FL 34243 (941) 359-8228 Contractor: Solar Direct Kirk Maust, CVC56728 6935 15th Street East, Suite 120 Sarasota, FL 34243 (941) 359-8228 Solar Direct • 693515Th St E • Sarasota FL 34243 • P 800.333.9276 F 800.897.6527 Onstken PIVInoltalc Astern peeforessrampredIctions aludated by PWIettelb include natty itthlITSI7t assumptions end ancattalates end do not reflect Nonagons batman PV technologies mar Ate-sPedfic theracteristio magi as roMmeated by WAbtbaN Mmes. Pro maple, PV modules vat better performance are not dIfferentlebei uthele PVINansen from team perfonthad modules. AN. NTOL and private companies prodde nem sephtsthated IV modeling teals (soch as the thetern Miser Model et Mtm/fareareal.gmfl that aces for awns precise and complex modeling of loitasbons. Disdenear: The MAME Model (itmdar) Is prodded by the National Renewable Energy laboratory reaten. Add, le wonted by the Affiance for thetalnable Energy, LLC refliancel for the U.S. Department Of Energy (IOW) end nmY need ter anypurpons whatsoever. The mots 00E/NREI/AUIANCE shell realm used In tan representation, advertising, publicity cu edear mama whatsoever to adores or prated* anY oath Vet adopts or uses the Model. DOEINREWSLIANCE shell not prodde any support, ceasadana, training or assistance of mof bed with regard to the use et the Nodal or en updates, reddens or newsershans at the Model. YOU IMES 70 INDEMNIFY 00E/NRELJALLIANCE, AND RS PFFILINIES, OFFICERS, AGENTS, AND EMPLOYEB AGAINST ANY O.AD4 AN DEMAND, NODDING REASCANAINE At Kamera FEES, RELATED TO YOUR USE, =PACE, OR AMMON OP TICE f4200. FOR ANT PURPOSE WHINSOEYER THE MODES PROVIDED BY DOWNREL/AlltANCE 'AS IS° ND ANY EVRBS OR DRIED MES, INCUIDING SIR NOT METED TO THE IMPLIED WARRANTIES OP PERCHANTASILITY AND WEISS PAN A PARTICWAR PURPOSE ARE EXPRESSLY DISCIAMED. IN NO EVENT SHALL DOWNREIJAUINCE SE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIN. MOSES 0 13 ANY DAMAGES WHATSOEVER, INCLUDING MT NOT LIMITED TO CAM ASSOC/no EATOThE LOSS AT' DATA OR PROFITS, TOAD 4 MAY mar RPM ANY ACTION IN OVIDUCT, NEGLIGENCE OR aim TORIIOUS CLAIM THAT MUSES OUT OP OR IN CONNECTION WITS THE USE OR PERFanMANCE OF INS MODEL RESULTS Month 1,460 kWh per Year Solar Radiation AC Energy Energy Value (kWh/m2/day) (kWh) January 2.24 62 7 February 2.94 80 10 March 4.11 131 16 April 6.08 162 19 May 6.24 201 24 June 4.25 130 15 _ July 6.01 190 23 August 6.33 169 20 September 4.05 123 16 October 3.30 101 12 November 2.28 62 7 December 1.90 60 6 Annual 3.98 1,460 $ 174 Location and Station Identification Requested Location 1037 91 terrace, 33138 Weather Data Source MIAMIIOPA LOCKA, FL (TMY3) Latitude 25.9° N Longitude 80.28° W PV System Specifications (Residential) DC Rating 1.6 kW DC to AC De rate Factor 0.77 Array Type Fixed (open rack) Array Tilt 22.8° Array Azimuth 0° Initial Economic Comparison Average Cost of Electricity Purchased 0.12 $/kWh from Utility Cost of Electricity Generated by System 0.31 $ficWh These values can be compared to get an idea of the cost-effectiveness of this system. However, system costs, system financing options (Including 3rd party ownership) and corn plex utility rates can significantly change the relative value of the PVsystem. st, Oration: PhOomitalc *tem performance predictions RESULTS — calculated by Matt* Wade many Mberent assumpeem and uncedairMes and de not reflect Month Solar Radiation AC Energy Energy Value varlatiens heaven by technologies nor sita•spedfic cheradarldim emept as represented Irr Matte& (kWh/m2/day) ( kWh ) ( $ ) WPM& For Maniple, FY modules sigh better Performs= ate not dfffereadiated *rade PYWatts® from lesser performing modules. Bath NREL and January 5.29 176 21 innate companies prod& more sopidstketed PV modeling tools (stab as the Spasm AMime Medal et February 6.33 159 19 itipli......14.0 two., fer mere predse and complex modeling .I PV. 2,025 kWh per Year March 5.74 187 22 April 6.83 185 22 DIsdaltner: The P104040 Model Moder) is Prodded by the Madrona! Remittable Energy Laboretory ("PIPEL"), WW1 hs operated by the May 6.19 197 23 Manor for Sustainable Energy, UC (anee) for the US. Danube.* Of Enrage MORI mid MY he June 4.06 122 16 used for arm purpose whatsoever. lite names CDERSPELJALUANCE shall not be used In July 6.87 184 22 any representation, acharbsing, pablidty or other memo Mamma, Or ender. or pro:note any entity that adopts re uses the trodel. DOEINRISJAUSANCE August 5.81 183 22 shall not prod& eml suPPort, consultrip, halting cw essistrma a f erty September 5.19 158 19 kind with regard to the use of the Model or ems, — updates; reddens or nem verelansaf dm Model. October 5.28 171 20 YOU NSW TO IADENNTFY DOE/NRILUEUNSCE, — --- AND ITS fawns, OFFICERS, AGENTS, NW November 4.69 148 18 EMPLOYEES wow ANY CIAIM OR DEMAND, INCLUDING REASONABIE ACITOPNEIW REUMID TO YOURU ONON'40000140400 December 4.67 155 18 THE PROM FOR ANY PURPOSE SOWISOMIER. THE MODEL IS PROVIDED INDOEMPEIOLLIANCS 'AS AND ANY IDPRESS OR IMPLIED WARRANTIES, Annual 5.33 2,025 $ 241 DICLUDING OUT NOT UPEND 10 THE IVIED VANIRSAMES OP MERCHANTABILITY MID FITNESS FOR A PANICUI/G PURPOSE APE IDPRESSLY mamma IN NO VENT SHALL DO40NR71/AUTANCE BE LIABLE FOR ANY SPECIAL, Location and Station Identification INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES YPIATSOEVEA, INCLUDING BUT NOT _ LIMED TO GNPS ASSOCIATED WITH THE LOSS OF Requested Location 1037 91 terrace, 33138 DATA OR PROPTIS, MAY RESULT FROPI ANY ACTION IN CONTRACT, NEGUGMBP OR OTHER TORTIOUS CUM THAT ARISES OUT OF OR IN Weather Data Source MIAMI/OPA LOCKA, FL (TIVIY3) CONNECTION WIN 10001000 PBFORMANCE OF IKE MODEL Latitude 25.9° N Longitude 80.28° W PV System Specifications (Residential) DC Rating 1.5 kW DC to AC Derate Factor Array Type Array Tilt 0.77 Fixed (open rack) 22.8° Array Azimuth 180° Initial Economic Comparison . . . Average Cost of Electricity Purchased 0.12 8/kWh from Utility Cost of Electricity Generated by System 0.22 $!kWh These values can be compared to get an idea of the cost-effectiveness of this system. Howeuar, system costs, system financing options (including 3rd party ownership) and complex utility rates can significantly change the relative value of the PV system. D 1 1% E tlC T Customer Billing Information Girirzgin down So Rev: Harke, Lance (SPV) Proposal #3- PMT V2.9cS . Name Lance Harke * ** INSTALLATION AGREEMENT * ** Prolect Installation Information Additional Name Contact Name' Lance Harke Additional Contact Name Address 1037 NE 91 Terrace City ST Zip Miami FL 33138 Phone - Hm IV 305)502 -8273 Cef Phone - Wk 305)Fax 536 -8222 Address 1037 NE 91 Terrace City ST Zip , Miami FL 33138 Phone - Hm (305) 502-8273 Phone-Cell Sub- Dwision County Dade Phone - k 3051536 -8222 Fax EMU iharke8lharkeclasbv.com Email iharke<? harkeclasby.com Solar Power Production System - Grid Connected 1 30 HanWha 250W Modules w/Enphase Inverters, Total kW: 7.5 Roof Angle / Pitch # of Stories Roof Type Module Mounting Wire Run (over 100ft) Trenching (ft) Total Arrays (Contiguous Modules) Additional Inverters Optional Battery Backup Optional Monitoring Options / Special Provisions CONTRACT AMOUNT: $27,920.28 PAYMENT DRAW SCHEDULE: Type Engineering Pymt Equipment Pymt installation Pymt Sales Representative 1/12 - 5/12 / 4.76 - 22.62 2 Concrete Barrel Tile Standard Roof Mount 0 0 1 0 None None None Amount $ 9,772.10 $ 13,960.14 $ 4,188.04 Archie Pacheco Method Check Check Check Due Upon Initiation of Contract Upon Engineering Completion Upon Completion of Installation Date 11/14/2013 OWNER ACCEPTA ,; - The prices, specifications and conditions within this agreement are satisfactory and are hereby accepted. Payme e/ be made as outlined q4e. 7 Authorized - olar Direct Executive Approval: Date Date Page 1 of 3 Owners Initials Solar Direct • 6935 15th St E • Ste 120 • Sarasota FL 34243 • P 800.333.9276 F 800.897.6527 Date r S Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 al spy Permit No: R eiN'_211 Structural Critique Sheet Page 1 of 1 1 2 E V I ' S E w e l 4 L- , 4 - b CAL%- • -core 14-s- rtP H - 1 0 1 W D &pc-r; ' - S PEc4'N 1 w Cf 4'!- 7 .-r r s0Lit -e- 1° BLS ow 1 g'1 <s . STOPPED REVIEW Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Mehdi Asraf