Loading...
RF-14-381Inspection Worksheet ' Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 208103 Scheduled Inspection Date: May 09, 2014 Inspector: Rodriguez, Jorge Owner: DUNN, JOHN NICHOLAS Job Address: 70 NW 94 Street Miami Shores, FL 33150- Project: <NONE> Permit Number: RF -2 -14 -381 Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat I:2rT [Tamil, I-117—T, Parcel Number 1131010340210 Contractor: PAUL KAWALEK ROOFING CO. Phone: (305)754 -0191 comments TEAR OFF EXISTING TILE/FLAT REPLACE WITH A NEW TILE/FLAT ROOF SYSTEMS ROOF TILE WILL BE BORAL BARCELONA 900 COLOR THROUGH CONCRETE AND COLOR IS CASA GRAN BLEND INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction �� o ✓ ,�� �c�G ��� - Needed ❑ ����� Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. May 08, 2014 For Inspections please call: (305)762 -4949 Page 7 of 21 RE: Permit #_ Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION AFFIDAVIT DATE: 511114 I Ka-u/a 1 licensed as a Egictor / Engineer / Architect, (Print name and cirde license Type) FS 468 Building Inspector License #: On or about 11 1 " 0® AM ,1 did personally inspect the roof deck nailing and (Date 8 time) Secondary water barrier work o Nw qq+h5+ (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) M. Signature State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of U _ Notary Public, Sate of Florida at Large Notary Public State of Florida 'oanna M Feliciano MY C mmmisslon FF 082753 Expires 01/12/2018 'General, Building, Residential, or Roo* g Contractors or any individual cerNed under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each inspection Revised on 500M F.I.E. FLORIDA INTERNATIONAL ENGINEERING &TESTING LAB INSIGHT - INNOVATION- INTEGRATION Owner's Name: �J 0 6'\ n L Job Address: -1p 1�d W Roofing Contractor: Permit Number: iz: 2 -14 3 Approximate Roof Height: feet Type of Access to Roof: -'— Ladder Florida International Engineering and Testing Lab LLC 16701 SW 117 Avenue, Miami, FL 33177 Telephone: (305) 378 - 1991 -Fax: (305) 378 -1997 Miami -Dade Lab Certification # 07- 0612.11 -State of Florida.ca #27273 SITE SPECIFIC INFORMATION Type of Tile: L'S ,i O�k Ke- - I P> Pok _ I Slope: 3' Approximate Square Footage: OtherRequired Testing orce: 35 lbs. Testing Equipment: F.G.E.100x Shim o Instrument Date Installed: Date of Inspection: _�2 TEST RESULTS P= PASS, F= FAIL Test Location P or F Test Location P or F Test Location P or F Test Location P or F Test Location P or F 1 & Gj 21 Hips & Ridges 41 61 81 2 22 42 62 82 3 23 43 63 83 4 24 1 44 64 84 5 25 45 65 85 6 26 46 66 86 7 27 47 67 87 8 28 48 68 88 9 29 49 69 89 10 30 50 70 90 11 31 51 71 91 12 32 52 72 92 13 33 53 73 93 14 34 1 54 1 74 94 15 35 55 75 95 16 36 56 76 96 17 37 57 77 97 18 38 58 78 98 19 39 1 59 1 79 1 1 99 20 40 1 60 1 1 80 1 1 100 ---------------------'-------------------- 011 -- — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — - — — ------- - - - - -. IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. ADDITIONAL TEST INFORMATION Perimeter Width: ft Area Units or fe No. of Tests Perimeter pty I (p Field PV 9 Corners -Z Hips & Ridges y ,- RESP ro®easrreem® F�Lltl$fED BY: ® 4;�7° No 63107 tea: 5 -g� Aai ® S T O Va g .)ala VP-a -1g- Sta,R� 4z 7 rp ,v Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (3055) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING OWNER: Name (Fee SimpleTiitlgholder):, Address: r7® VyW q'4- �h sl Permit No. Master Permit No.2i }' I y 4 ,� S]. OS 95 b -5b9A City: Kiaml i h®reS State: rL Zip: 33138 Tenant/Lessee Name: Email: JOB ADDRESS: " 1® N W q q +,, —sf City: f Miami Shores //�� County: Miami Dade Zip: 33150 ' VOI Folio/Parcel#: `���It) I- O Is the Building Historically Designated: Yes NO V1___ Flood Zone: AV CONTRACTOR: A,Company Name: PO.. &i H &wed � 900 I d1 Q� Phone#: ��� P]5 -D 1 q % Address: �� ► �a b `�`"'�e�`F City: M l r o_m w State: 1F1-- Zip: 3 3 ®G V'/ Qualifier Name: 04-wa. I /� /� Phone #: � __J l�-�r State Certification or Registration #: � ®® (0 "l )5 Certificate of Cpmvetencv #: b 6-50 0®® Contact Phone #: DESIGNER: Architect/Engineer: I � Phone #: Value of Work for this Permit: $. ®0 ; a �r F e a' 1.1, r� s Qu o £tl 1 go I lq Type of Work: OAddress OAlteration Description Work: 4�&rO �C I �`�i &tslc • ?fi8tj� rc r NcWWy'Ctlair/4 ODemolition of t ;,• ti�f 0�-�•` . i' �Gt Cse L� `6I e r�.v�. d a. ®• r'� Ste, K,; S ®N �, yS p'���ywry y e �r,1 ° ° 0 or �a�+`k 6. 18 9 \°°• y 1 R t D �'!A y &o let-, ' e, ® y9Q x'11 &L 5d I Vhf' � de- 6 lend-, COLOR THROUGHROOF TILE IS REQUIRED ac/stowledged by: Submittal Fee Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE n - Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The f (eing instru ent was acknowledged be re me this The foregoing instrument was acknowledged before me this day o cv®s 20 04 by J 'CLAM M- 2) u, 1W\ day of . 20 by who is personally known to me or who has produced FL.1b L who is personally known to me or who has produced ' As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: �...N�. JEAN OAWESTWEL l NOTARY PUBLIC: a ° = Notary PubNe - St1� 01.E MY Comm. EaptN May $.'2017 Sign: 014417 Sign: Print: — 6 IF Print: My Commission Expires: 'Z"0 Q My Commission Expires: APPROVED BY 3 Plans Examiner Zoning Structural Review Clerk (Revised 07/10/07 )(Revised 06 /10/2009)(Revised 3 /15 /09)(rev6 /4/10) OWNER'S AFFIDAVIT OF EXEMPTION ROOF To WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMII.Y REsIDENTL&L STRUCTURES PURSUANT To SECTION 553.844 F.S. To: Miami -Dade County Building & Neighborhood Compliance Department 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name 'I® ttt - Property Address 76) 14 V:) ct `{ ( o Roofing Permit Number Dear Building Official: +t'� 'D V ri J certify that I am not required to retrofit the roof to wall connections of my building because: L'J The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. UThe building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). Print Name STATE OF FLORIDA COUNTY OF NUANH -DADS I '' Sworn to and subscribed before me this w...,, .•`�" a "4•., JEAN DAYYESTI LQIgB ` day of ft)p V 20�_, Notary PW flo - Sam of ftft M 5. "17 MY, Conan, ENO" y (SEAL) Cdowds" I FF 014417 Personally known or Produced Identification if `, 'EA, -DS 0a t+74 49 2-S .4 b When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided e : FEg ti :8 204 Seaton A (General lnfonnation) Master Permit No , >s— coact es Namte � Job Address ' 1 j wfr!c�crry i ROOF CATEGORY Low Slope ❑ Mechanically Fass9ned Tile 1� tAMoTWA dheelve Set Tle ❑ Asphaltic ❑ Metal Panoshingfas ❑ woad sidrGles�Shalc�s Shingles ❑ Rr+DScriptive HUR-RAS 950 1 ROOF TYPE ❑ New Roof U� Reroofing ❑ Recovering ❑ Rehr ❑ M ROOF SYSTEM 9IFORMATION Low Slope Roof Area ($F) Steep Sloped Roof Area (SF) Total (SF) -tqoo )q50 SOCUon B (Roof Plan, Roof Plan: illustrate an levels and sections, roof drains, scuppers, overman o and overflow drains. Include dimensions of sections and levels, dearly dimsnsions of elevated pressure zones and location of I CUD An t_ ��. Q yt w ! • • • • E'7 ll{ "mil✓ t y " •� _ . • r .. { . i � j ,' Lij c •. I ....L '7 . Q N m t tj c t • • • • E'7 ll{ "mil✓ t y " •� _ . • r .. { . i � j ,' . Fkwtda OuNdIft Cob EdUbm 2010 ' ftm- pedmekr am woe ftqwwThwmqw- em bmAeffm FmftnmkWnft Makffink Bow WNW$) & ft Of plxsy, Ehme glad FSSWI$Oft ply wed QP- Mo FA (pWwAiAeA lwlnvroj Cap q 11 ma*Ge4 'If -p 11*4 V—:vIni-tvw� it to r f0 Fr] 01 tl is 0 w a 0 V r , 's ■ r ■ r ■ i ■ ■ i r ■ • • • Florida Building Coda on 0 n i x . t oroJ ' Rif Stem �'i�r - i PmdudAPPWVW Nwnber. Minimum D"Wn Wind Pte. If APPIiC ble (From RM 129 or P4. 3q %) - - -P2: ��� - -p3: 1000 Maximum AWWVW PcdW, Method of ale afsnnm nt 1 R Sip StaAed Roof System Die Oodon f3ack Type: ! 1rt'�"' W D 0 cl I \Flre r 564 i Roof Slope: :12 — ��i Bldg* Ven ilatfonpe & Spacing: 1_ i� , 5 AWIS vs Type gyp$ - - - ili�r► � f ► ' MA p 1 i Florida Building Ccde Edon MO . i, Hinh V4kw2V HUffkane Zone Unftnn Pm. AnnUcaffan Rum 11 .71 Swfion E Mile QljSd@VSm j For Moment bused tae systenth choose either b$cftd iL or 2. Compared the vwue� for Mrvd& the vulva hvm WU If the K values an greater than or equal to the WWI, values, for each area of the rGA then the file attachment method Is acceptable. Method 1"Moment Based Tile Caleakdow Per RAS 1270 PS; Mk-:Mr, U-6 FwadadAffmdM, w; z&j Mw-qAb rn*AdA mt i IP21*1 t. Method. 2 "Simplified Tile Colenlatim Per Table Dde*" Required Moment of Resistance (M,) From Table Bebw 7, —,, 1, Where tsfind VWV?ft=w Plorl"UrPS RAS 127T"IwSimii-ow—iiiiiiisEby ffTbNW4mASCE-' 7 V.m RNWI%W- H TM I. ResbMw KWUNIM r NJ ftw-qgm, I Gwhumftd AywmpvTHe!W:1K- w is *Must be used In 40oJusetion whb a rat of moment based We mptems endwsed by the Broward County Board of Rules and Appeals. For UpUft band We systems use Wthed 3. Compared the values for r with the;� values for Fr. If the F values am greater than or equal to the Fr values, for each aura of the rout, then the file attachment method k aceeptattle. Method 3 -UpUff Based TVs Calculatlow Pow RAS 127" )-W._xeos& rs F, e. (pa; I CBS 6 & Fa: Where to Obtain Jefor3nadon Where tsfind VWV?ft=w Plorl"UrPS RAS 127T"IwSimii-ow—iiiiiiisEby ffTbNW4mASCE-' 7 V.m RNWI%W- H I. ResbMw KWUNIM r NJ ftw-qgm, I Gwhumftd AywmpvTHe!W:1K- w Avd Anavd VI-Via J( 0001 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of pro ' 'ng that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be fiiiak in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to moving the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring un e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owper-shbiuld notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can /16wed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the a a 5. Ponding water: The current roof system and/or deck of the building may not drain well and may water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural WMr distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the f ng system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not rom a buildup of water. Perimeter /edge wall or other roof extension may block this discharge f ppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in acco with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the i o of the structure assembly (the building itself). The existing amount of attic ventilation shall not be red . It may be beneficial to consider additional venting which can result in extending the service life of the Contractor Signature Date Revised on 7/9/2009 LD � � t � t COUNTY �� MIANII -DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES MM) Miami, Florida 33175 -2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315 -2590 F (786) 31525 -" NOTICE OF ACCEPTANCE (NOA) www.miamid"e eov/ecrnomv GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GAF Ruberoie Modified Bitumen Roof System for Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entiro$1'bAI&A lie p&vi$ed tv tfle user by the manufacturer or its distributors and shall be available for inspection at Itte j oli sate it nth® ra9WO J of the Building Off cial. This NOA renews and revises NOA No. 09 Ul24.061 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. . ... . . ... . . . . . ... . . . . .. . . . . ... . NOA No.:13- 0424.14 aodaoe ... . . . . . Expiration Date: 11/06/14 .. , , • • • . . Approval Date: 10/31/13 0 0 Page 1 of 29 . . . . . . . . . . . .. .. . . .. .. ... . . . ... . . ROOFING SYSTEM APPROVAL Ca o : Roofing Sub- Cateeorv: Modified Bitumen Material: APP /SBS Deck Tyne: Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED I TABLE 1 Test Product Dimensions Specification Matrix"' 102 SBS 5 gallons ASTM D3019 Membrane Adhesive 3R LABELED BY APPLICANT: Product Descrintion Fiber reinforced rubberized cold- applied adhesive for modified bitumen roof GAFGLAS® #75 39.3T' ASTM D4601 systems. Type H asphalt impregnated and coated Base Sheet (1 meter) Wide glass mat base sheet. GAFGLAS® #80 Ultima7 39.3T' ASTM D4601 Type H asphalt impregnated and coated, Base Sheet (1 meter) Wide fiberglass base sheet. GAFGLAS® FlexPly 6 39.3T' ASTM D2178 Type VI asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS® Ply 4 39.37" ASTM D2178 Type IV asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS ®Mineral 39.3T' ASTM D3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet (1 meter) Wide surfaced with mineral gramiles. GAFGLAS® EnergyCap"' 39.3T' ASTM D3909 Asphalt coated, glass fiber mat cap sheet BUR Mineral Surface Cap (1 meter) Wide surfaced with mineral granules with Sheet factory applied EnergyCote7 GAFGLAS® Stratavene 39.3T' ASTM D4897 Fiberglass base sheet coated on both sides Eliminator Perforated (1 meter) Wide with asphalt. Surfaced on the bottom side Venting Base Sheet with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS® Stratavene 39.3T' ASTM D4897 A mailable, fiberglass base sheet coated on Eliminator Perforated (1 meter) Wide both sides with asphalt. Surfaced on the Nailable Venting Base bottom side with mineral granules Sheet embedded in asphaltic coating. Ruberoie SBS 39.3T' ASTM D6164 Non -woven polyester mat coated with Heat Weld' Smooth (1 meter) Wide polymer- modified asphalt and smooth surfaced Ruberoie SBS 39.3T' ASTM D6164 Non -woven polyester mat coated with Heat -Wehr Granule (1 meter) Wide polymer- modified asphalt and surfaced •' 0% • • • • • with mineral granules. RoofMatch7 107 ;q. ft..:.'1SM 06:64. Non woven polyester mat coated with SBS Modified Granular (9: j�72)• • • • • • •' SBS polymer-modified asphalt and surfaced with colored mineral gramiles. Ruberoie SBS 39.3'x' QSW D6d0 lion-woven polyester mat coated with fire Heat - Weld's 170 FR (1 truer) � ide : : rbarrdant polymer modified asphalt and ' : • •' % : surfaced with mineral granules. NOA No.: 13-0424-14 ... . . ... . . Expiration Date: 11/06114 JAPPROVEDI Approval Date: 10/31/13 • • • . •• • • • • • • •• • . . •. •• • Page 2 of 29 ... . . . ... . . Membrane Type: SBS/SBS Cold Applied Deck Type 1: Wood, Non - insulated Deck Description: '9/32" or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOuim Fire Barrier Coating, VersaShiele Fire - Resistant Roof Deck (optional) Protection or SecurocO Gypsum-Fiber Roof Board. Base sheet: GAFGLAS" #80 Ultima TM Base Sheet, GAFGLAS" Stratavent" Eliminator Nailable Venting Base Sheet, Ruberoid" 20, Ruberoid" SBS Heat Weld"` Smooth or Ruberoid" SBS Heat- Weld'm 25 base sheet mechanically fastened to deck as described below: Fastening GAFGLAS" Ply 4, GAFGLAS" F1exPly 6, GAFGLAS" #75 Base Sheet or any Options: of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS" Ply 4, GAFGLAS" FlexPly 6, GAFGLAS" #75 Base Sheet or any of above base sheets attached to deck with Drill-Tec' #12 Fastener, Drill -TecTm #14 Fastener or Drill-Tec'm XHD Fastener and Drill-Tec"' 3" Steel Plate, Drill- Teo'" AccuTrac" Flat Plate or Drill-Tec"' AccuTrac" Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS® F1exPly 6, GAFGLAS" #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener sptg of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. mum Design Pressure -52.5 psf, See General Limitation #7 GAFGLAS" #80 Ultima7 Base Sheet, Ruberoid" 20, Ruberoid" Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure -60 psf, See General Limitation #7) GAFGLAS" #75 Base Sheet or any of above base sheets attached to deck with Drill-Tec- #12 Fastener, Drill -Tec #14 Fastener or Drill -Tec"' XHD Fastener and Drill-Tec'm 3" Steel Plate, Drill-Tec AccuTrac" Flat Plate or Drill -Tec7 AccuTrac" Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The othoraowsaw equally spWed+Woximately 9" o.c. in the field of the sheet. • • + + . + ( Mxdmum A&inrNIIure i6� pc.�' See General Limitation #7) Any of above base sheets attached to deck approved annular ring shank nails and 3" invertfd DrMJTec� insulation plates at a fastener spacing of 9" o.c. at the 4" lap stagafgl i4twg rot's 9S' 1 the &1& (MaximumMe$tn Pftjure.160 p+&k -, General Limitation #7) NOA No.: 13-0424.14 • • • • • • • • • • • Expiration Date: 11/06/14 Approval Date: 10/31/13 • • + : Page 25 of 29 1 GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-Tec #12 Fastener, Drill -Tecm #14 Fastener or Drill-TecTm XHD Fastener and Drill-Tec"" 3" Steel Plate, Drill-Tec .. AccuTrae Flat Plate or Drill-Tec' AccuTrae Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional) One or more plies GAFGLAe Ply 4, GAFGLAS® F1exPly 6, GAFGLAS® #80 Ultima Base Sheet, Ruberoie Mop Smooth or Ruberoie 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Membrane: One or more plies of Ruberoid® Mop Smooth, Ruberoid Mo 170 FR, Ruberoidl® Mop Granule, RoofMatch7 SBS Modified Granular, Ruberoid Mop Plus Granule, Ruberoie 20, Ruberoie 30, Ruberoie EnergyCap 30 FR SBS Membrane, Ruberoie 30 FR or Ruberoie Mop FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Or One or more plies of Ruberoie Mop Smooth, Ruberoie Mop Granule, RoofMatch"' SBS Modified Granular, Ruberoie Mop 170 FR, Ruberoid® Mop Plus Granule, Ruberoie 20, Ruberoie 30, Ruberoie EnergyCap"30 FR SBS Membrane, Ruberoie 30 FR or Ruberoide' Mop FR adhered in Matrix' 102 SBS Membrane Adhesive at an application rate of 1 -2 galJsq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. 2. GAFGLAe Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCap BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. 3. Topcoat® Elastomeric Roofing Membrane, Topcoat® MB Plus (to be used as a primer with Topcoat® Elastomenc Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gaUsq. Maximum Design Pressure: See Fastening above ....... . .. .. . .. . . . . ... . .. ... .. . . . .. . .•. • . ••• . ... . . . . . . . . . . . . . . . . . . . •• . . • •• . • . • . • . • • • . • . .. .. • . . •. .. .•. . . . .•• . . NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Pane 26 of 29 t WOOD DECK SYSTEM LDwAuow 1 A slip sheet is required with GAFGLAS" Ply 4 and GAFGLAS" FlexPly Tm 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum ' /a" DensDeck" Roof Board or 1/2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LmTATIoNs: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered m a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). heilhq rptional analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressW44rigs 4.� p eters, extended corners and comers). (When this limitation is specificall %refetr4l JviM tidi NOA, General Limitation #7 will not be applicable.) 00 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9X-3 oflbt Florid 4dpm9tTti pa ode. ENMATWS jkVC1J1P 'ANCE • • ••• • • • NOA No.: 13-0424.14 Expiration Date: 11/06/14 • •. • • •. • • • Approval Date: 10/31/13 • • • • • • • • • Page 29 of 29 • ••• •• • •• • • • • • ••• •• • •• • a TGFU.R1306 - Roofing Systems Page 1 of Claw A — rwny Atthered 1. auk NC Incline. 112 Insulatlon (Optional): — One or nwre layers pedit a or wood fiber or glass fiber or polyllocyanurat e or urethane or perlite/polynsocyanurate composite or perme/urethane composite or woof fiber /polyisoeyanurate composite or phenoif -_amr it k�mess. - - - _ - - Rom Sheet (Optlonags — One or more piles Type Gl or Type G2 or Type G3. Membranes — One or more plies "Ruberolde Torch *" (Smooth or Granule) or "Ruberold® Torch Granule Plus° or "Ruberolft Mop' (Smooth or Granule) or "Ruberoids Mop Plus Granule" (granule). - Surfaring: — Gravel, 400- lbs/100 -ft2, looms laid or applied in a flood coat or hot roofing asphalt. 2. Deets: NC Uldine: 1/2 Base Sheet (Optional): — One or more plies Type GI or Type G2 or Type G3. Membranes — One or more plies "RuberoldO Torch" (Smooth or Granule) or "Ruberoid® Torch Granule Plus" or "Ruteruid& Mop" (Smooth or Granule) or "Ruberold® Mop Pius Granule ". Coatings — "Karnak No. 9T applied at I% to 3- gal./1004t2. 3. Decks NC Indine: 1/4 Insulation (Optional): — One or more layers periRe, woad fiber, glass fllmr, any thickness. Base Sheet (Optional): — One or more plies Type G! or Type G2 or Type G3. Membranes — One or more plies "RubemWQ Torch" (Smooth or Granule) or "Ruberoid® Torch Granule Plus" or "Ruberoid@ Mop Granule° or "Ruberotd® Mop Plus Granule". Coating: — -Kemak No. 97" applied at ilk to 3- gal/1o0 -ft2. 4. Dacia C -15/32 Inca m 1/2 insulation: — One or more layers partite, glass fiber, polyisocyanurate, urethane, pedite/polylsocyanurate Cosn{osite, pedWurethene composite, phenolic, IV--In. minimum thickneo (butt joints staggered a minimum of 6-1n. form plywood dock bUtt jOUM). Base Sheet: — One or more plies Type G2 or Type 63. Ply Sheet (Optional): — One or more plies Type GI. Membranes — One or more plies "Ruberokf® Torch- (Smooth or Granule) or "Ruberoki® Torch Granule Plus" or "Ruberoid® Mop" (Smooth or Granule) or "Ruberoide Mop Plus Granule." Surfacing: — "Karnak No. 97" applied at I% to 3- gat/100 -ft?. S. Decks NC Isocline: 1/2 Base Sheet (Optional)s -- One or more plies Type G1 or Type G2 or Type G3. Membranes — One or more plies "Ruberoid® Torch" (Smooth or Granule) or "Ruberoid® Torch Granule Plus." Surfacing (Optional): — Karnak "No. 97" or "169" applied at 1 to 3 gaU100-ft2 or Grundy Ind. -20 P Emulsion- applied at 3- gal /11W -0. 6. Deck C -15/32 Inclines 1/2 Insulations — One or more layers partite, glass Fiber, .214-in. minimum, polyisocyanurate, urethane, perlite/polyl cyanurate composite, pertltelurethane composite, Wi-in. minimum. Bake Sheet (Optfonai)s — One or more plies Type GI or Type G2 or Type G3. Membrane: — One or more plies "Rubaroid® Torch" (Smooth or Granule) or -RuberoM Torch Granule Plus- or - Ruberoid® Mop" (Smooth or Granule) or - RuberoidO Mop Plus Granule. - Surfacings — Gravel. 7. Deck: C -15/32 0':1 i' Insulation (Optional); — One or more layers peritte, wood fiber, glass f lw, polyisocyanurat% urethane, perittEtpolytsocyanurate composite, periite/urethene composite, wood fiber /polyisotyanurate composite. Base 5hsunt! — Two or more plies Type G2 or Type 13. MY Slut (OptlOtlfil): — One or more plies Type GI. Membreaw. — One or more piles "Ruberofdsb Torch" (Smooth or Granule) or °Ruberoid® Torch Granule Plus" or "RuberoWe Map" (Smooth or Granule) or "Rubcrold@ Mop Phis Granule. - Surfacing: — "Karnak ft. 97" applied at ij%w0eWVJ0Q-f0 Or gW4V. • • sa. Dacia NC • • hI&I 1/2i i • i • • •• ••• •• • • • •• Immlatiom — One or more layers partite, glass fiber, 3A -m, minimum polylsocyanurate, urethane, perdfle/palylsotyanurate Composite, pernte/urethene composite, SOS in. mirgmum• • • • • 040 • Mwn Sheet non - One or n- —Ones " t�fvge (ot!TV t I � uC -la o ltombraneu - s]r�e or more plies "R��� a'orc�" ( r axi ) tile!► T6rCn GranUlE PIUS" Or °RUberblq® Mop" (Smooth or Granule) or "Ruberoid ®•NiopePkss s3murule. • • • • • Suofathsg: — Grundy "Ai. MB Aluminum roof t:oaling'O ftiietf at 1 to 2agat /i60_ft2. ••• • • • • ••• • • 1lttn- / /d.gtahaeAnlrnm /rat hin/ XVVjP4" iw w/$ NF4- r/3 r4p t3 3hRl. �t,. ,..,...►,.ei,+..,to.,....... —�r c�►ornnsn •• •• • • • •• •• ••• • • • ••• • • tTGFU.R1306 - Roofing Systems Page 2 of 2 9. Oedu C-15/32 India: 1/2 Insulatlon (optbas ): — One or more layers perlite, glass fiber, 46 -In. minimum, polylsocyanurate, urethane, PerIl /,-,I; tsoc)anurate composite, perlitelureihane composite, phenolic, 1'h in. minimum. Base Sheet: — One or more plies Type G2 "GAFGLASO e75 Base Sheet , or °Tr{ -Pt ® *75 Bas Sheet", or me-hani+caliy fastened in place. w Ply Sheeto — One or more plies Type G1 .. Ply 4" oh 7rl -Ply® Ply 4" or °C,AFGLASS Ply 6" hot mopped In pLxs: - - Membrane: — "Ruberoid @. Mop 170 FR° or °Ruberoid@ Dual Fib or °Ruberoldo Poop FR" or "Ruben&* fitergyCap°' Phop FR. "° Surfacing — (Optional): "GAP I'Mered Aluminu Ung° appiled at i'h- gay100 -ftz or "GAF Weather Coat " aoilie�l ac 3- gal /100 -tt�. l0. tDlCk= tr -15!32 ; lmtlne. vw Insulation (Optional): — Perlite, fiber glass, polyiscyanurate, urethane or pedtte /polylso yanurate comma. - Base Sheens — One or more layers Type G2 "GAFGLASO #75 Owe Sheet° or OTH -Piy® *75 Bas Sheet" or G3 "GAL;: ® Mineral Surfed*. Cap Sheet" or °TrI-PIy* Mineral Surfaced Cap Sheer. tt��ggtt mopped or "nw0wicaliy fastened. PIy Sheet (Optioned): — One or more plies Type G1, hot mopm in place. i 'K a Membrane: — "Ruberolde Mop 170 FR" or "RubemfdO Dual FR" br.. "RUberoidWillop FR" or"wmqWo aveigyCap"" Mop FR.- ago ••• • • • • ••• i • hltn• / /rlatal►aentil rnm/ rm_ 1 .;n/YV�j/ +o�„�l�fo��C1>:D�A1��� t ..............ts...to........ =r crnornn�n = ••• • • • ••• • • � •� a'o: i. ..ts"arcw -u+. w.*;aaatQG..F..x "�.VF wwzgcwaos6 +:cwcasm".w- .r.+�•n......: � � • 'v... , :: ► . • •• 0 • • i ••• • • •• • ..• i i • •• • • • • ••• • • • • ••• i • hltn• / /rlatal►aentil rnm/ rm_ 1 .;n/YV�j/ +o�„�l�fo��C1>:D�A1��� t ..............ts...to........ =r crnornn�n = ••• • • • ••• • • 0~1If A AM1 ®1 + a r MIAMI -DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Sheet, Room 208 BOARD AND CODE ADAUNISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315-2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www.ndamidadexeyleconomy Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11- 1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. =w � APPROVED NOA No.: 12 -0713.02 Expiration Date: 09/13/16 Approval Date: 02114/13 Pace 1 of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub- Category: Underlayment Material: SBS , APP Self - Adhering Modified Bitumen PRODUCTS DESCRIPTION: Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self- adhering, glass - Manufacturing Location 61' x 3'3 3/$" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering, glass - Manufacturing Location 61' x 31-'/8" ASTM D 1970 fiber /polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof file underlayment. NOA No.: 12- 0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 65'8" x 3'3j/8" waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefimc; film on the upper surface for #2 use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick IR -Xe Roll: TAS 103 and A fine granular /sand top surface self - adhering, underlayment 65'x 3'3j/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32'10" x 3'3j/8" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering, glass - underlayment 65' x 3'3 3/8" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof Manufacturing Location tile underlayment. #1 & #2 Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10" x 3'3j/8" ASTM D 1970 glass- fiber /polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a the roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self- adhering, glass - Manufacturing Location 61' x 3'3 3/$" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering, glass - Manufacturing Location 61' x 31-'/8" ASTM D 1970 fiber /polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof file underlayment. NOA No.: 12- 0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self - adhering, polyester Manufacturing Location 65'8"x3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed #2 60 mils thick as a a roof tile underlayment. MANUFACTURING PLANTS: 1.Hazelton, PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Arency Test Identifier Test Name/Report Date Exterior Research & Design, LLC 11756.04.01 -1 TAS 103 04/27/01 11756.08.01 -1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08 -R1 TAS 103 12/04/08 P10870.04.09 TAS 103 /ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103 /ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110 /ASTM D4798 & D1970 10/19/11 P40390.08.12 -1 TAS 103 & TAS 110 08/06/12 P40390.08.12 -2 ASTM D 1623 08/07/12 P40390,10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA- 005 -02 -01 ASTM D 4977 01/31/02 PUSA -018 -02 -01 ASTM D 2523 07/14/03 PUSA -035 -02 -01 TAS 103 09/29/06 PUSA -033 -02 -01 ASTM D 1970 01/12/06 PUSA - 055 -02 -02 TAS 103 12/10/07 PUSA- 083 -02 -01 TAS 103 06/30/08 PUSA -089 -02 -01 TAS 103 /ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103 /ASTM D4798 & G155 04/01/08 RX14E8A TAS 103 /ASTM D4798 & G155 11/09/09 DX23D8B TAS 103 /ASTM D4798 & G155 02/18/10 DX23138A TAS 103 /ASTM D4798 & G155 02/18/10 �unoE CouN NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release fihn as the membrane is applied.. All side laps shall be a minimum of 3 -'/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11-0713.02 tnaM�r►oe couNrir Expiration Date: 09/13/16 Approval Date: 02/14/13 Pate 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations @UsL Polystick MTS MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven, FL. 180 180 180 180 180 180 180 90 Hazelto PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct - to-deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick Ht-Xe Polystick TU, TU Polystick TU Plus, TU P, Tile Max Pro Flat Tile Prohibited without 5:12 No limitation No limitation battens Profiled Tile Prohibited without Prohibited No limitation No limitation battens The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. APPROVED NOA No.: 12- 0713.02 Expiration Date: 09 /13/16 Approval Date: 02/14/13 Page 5 of GENERAL LimrrATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of the directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. dl Q e 6j DO? ueCK PrgMMa Vffin POLYSRCKTU Rus I I 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAP1143ADE COUNTY BUILDING PERmyr REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. APPROVED NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 6 of POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7712" or greater. It is suggested that on pitch/slopes in excess of 6'/a "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. APPRQYED� NOA No.: 12 -0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING 1,11 IITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 12- 0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 8 Em 0 MIAMI DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Sheet, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) vmw•miaWdade.eov /sera Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#07- 0220.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. --°� NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04 /19/12 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Cateam: Roofing Sub- Catenory: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Date Test Product Apulic Dimensions Specifications Descriotion Barcelona 900 1 =17" TAS 112 High profile, interlocking, one-piece, 'S' w =13" shaped, high- pressure extruded concrete roof Testing of screw vs. smooth ' /Z' thick tile equipped with three nail holes. For direct deck or battened nail -on, mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS -112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL. 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Redland Technologies 7161 -03 Appendix III Redland Technologies Redland Technologies Redland Technologies 7161 -03 Appendix 11 P0402 Test Name/Reno rt Date Static Uplift Testing Dec. 1991 TAS 102 & TAS 102(A) Wind Tunnel Testing Dec. 1991 TAS 108(Nail -On) Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) NOA No.: 12- 0222.02 Expiration Date: 04 126/17 Approval Date: 04 /19/12 Page 2 of 7 i Redland Technologies P0631 -01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Professional Service Industries, IC- 1320 -94 Physical Properties Feb. 1995 Inc. TAS 112 The Center for Applied 25- 7688 -3 TAS 101 (Adhesive Set) June 1996 Engineering, Inc. 25- 7688 -10 TAS 101 (Mortar Set) July 1996 The Center for Applied 25- 7688 -5 Static Uplift Testing June 1996 Engineering, Inc. TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied 25 -76884 Static Uplift Testing June 1996 Engineering, Inc. TAS 102 (4" Headlap, Nails, Clips) Celotex Corporation 520111 -3 Static Uplift Testing Dec. 1998 Testing Services 520191 -2 -1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering, Inc. Evaluation 25 -7183 March 1995 Calculations Walker Engineering, Inc. Evaluation 25 -7094 February 1996 Calculations Walker Engineering, Inc. Evaluation 25 -7496 April 1996 Calculations Walker Engineering, Inc. Evaluation 25 -7584 December 1996 Calculations 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 122 TAS 112 January 2007 NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04 /19/12 Page 3 of 7 i 4 e , 3. I. nuTATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (lbf) Length -1(ft) Width -w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -X (It) Tile Profile x(ft) Batten Application x(ft) Direct Deck Application Barcelona 900 0.289 0.313 Table 3: Restoring Moments due to Gravity - M9 (ft -lbt) Tile 2 ":12" 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" or Profile greater Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 900 Deck Deck Deck Deck Deck Deck 7.28 8.13 7.21 8.05 7.10 7.93 6.96 7.78 6.79 7.61 6.61 7.40 NOA No.: 12 -0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 4 of 7 I . t , Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Nall -0n Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19132" plywood) Battens Barcelona 900 2 -10d Mng Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 .#8 Screw 20.7 20.7 18.1 2 .#8 Screws 43.2 43.2 29.8 1 -10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails Eave Clip) 38.1 38.1 41.8 Table 5: Attachment Resistance Expressed as a Moment Mf (ft -lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Adhesive 29: 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 10.7 grams. Polyfbam Product, Inc. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Polyfoam PoIyProTm 66.5 Polyfoam PolyProTm 38. 3 Lar a paddy placement of 6 rams of PolyProTm. 4 Medium paddy placement of 24grams of PoIyProTm. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set 24. 5. Tile -Tite Roof Tile Mortar gPPROVED��� NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04 /19/12 Page 5 of 7 I . F 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved ". LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERmrr REQmEMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. APPROVED NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04 /19/12 Page 6 of 7 PROFILE DRAWING NAIL HOLES 17" UNDERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE OVERLOCK 3 5/8 " %z 13" NOA No.: 12 -0222.02 Expiration Date: 04126/17 Approval Date: 04 /19/12 Page 7 of 7 MlAM MIAMI DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERK TI TING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www.m1anddade.wy/y Company 3M Center Building 0220- 05 -E-06 St. Paul, MN. 55144 -1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2- Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. F _qtr NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 I ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Descriution Suecifications 3MTM 2- Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Pro a Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.61bs. /ft 3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.070/. Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Aaencv Test Identifier Test Name/Reno Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB- 589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LINIITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTm 2- Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof file adhesive with their file assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. �F W _ �2 Fl— MS NOA No.: 12-0228.18 Expiration Date: 05/10/17 MIAMIOADE MrW Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0 (B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF 1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, M& Profiles #1 35 N/A ffigh Profile 2 Piece Barrel #1 17 /side on cap and 34/ an N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 1 1 8 APPROVED NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10 /12 Page 4 of 7 LABELING: All 3MTm 2-Component Foam Roof Tile Adhesive AH-1 60 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQumwws: As required by the Budding Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nab #M*hPwftCM.w Unb"-d 1 0 EMCMM FaKb wMew. EmOM 4hupfimweephdo Ft*@KNMTk) . . . . . . . . . . . . ....... . . . . . . . NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ....... . . . . . . . NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 Nall dm*h plastic cement 0 1 40>t Sk* ,., in Tx3in. unde dle Single paddy on 2 In. 41n. under- X7N- SinglopaW an top of via ADHESIVE PLACEMENT DETAm 3 DOUBLE PATTY Metween tile) (under 11118) W, "I through plastic cement Undulayment Nd ftmh plastic cement I 4NF'1IYLx3hL 1 4 In. Single Single paddy paddyon MOM under- layment Single on WOO Nd ftmh plastic cement Q 3 Im x 3 In. Single paddy MOM A END OF THIS ACCEPTANCE Single paft under the Single paddy between th 2 IL x 7 In. medhun shoe paddy em !Muse Only <_ �FaKle Ease dosin - 00 edge NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7