Loading...
RC-13-2827Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 204734 Scheduled Inspection Date: March 14, 2014 Inspector: Rodriguez, Jorge Owner: KOTALIK, KENNY Job Address: 950 NE 100 Street Miami Shores, FL 33138- Project: <NONE> Permit Number: RC -12 -13 -2827 Permit Type: Residential Construction Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1132060340200 Contractor: BDC CONSTRUCTION CORP Phone: (305)888 -5221 comments FIRE DAMAGE HOUSE RE- PARING DRYWALL - - - - -- INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. G� March 13, 2014 For Inspections please call: (305)762 -4949 Page 8 of 36 Miami Shores Village D� 2013 Building Department BY. 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 20 BUILDING Permit No. / PERMIT APPLICATION Master Permit No. 6 Permit Type: BUILDING ROOFING JOB ADDRESS: 960 N E 00"" MC U- City: Miami Shores County: Miami Dade Zip: 33 109 Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): Ven K [ 9 VI I ��- Phone #% " 3y s- 11 F(5 Tenant/Lessee Name: _ Phone#: Email: CONTRACTOR: Company Name: (n y 0• Phone#:305— 9 5 2 Address: City: �Q , � �� V State: 1 � � zip: Qualifier Name: Alberf de 10 v E90 Phone#: State Certification or Registration #: �,, A.r Ut Q L U J `I Certificate of Competency #: Contact Phone#: Email Address: Mbfff bficl �aA. c o DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ Square/Linear Footage of Work: L/00 Type of Work: UAddition UAlteration UNew ORepair/Replace ODemolition Description of Work: elck 11 8 Vj Color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ ` Bonding Company's Name (if applicable) ® Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose properly is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a r:ctionfee will be charged i — Signature Signature O,kner or Agent Contractor The foregoing instrument was acknowledged before me this 2—th day ofleL._, 20 -�5, by V)Ga��j i f- , The foregoing instrument was acknowledged before me this day of Dee- , 20a, by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. NOT PUB C: Sign: 0 Print: My C APPROVED BY Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06110/2009)(Revised 3/15/09) as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission # FF 42370 My Commission Expires August 04, 2017 Zoning Clerk JAWw44 • Commission # FF 42370 �mmissio '•. �� ply Commission Expires August 04, 2017 APPROVED BY Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06110/2009)(Revised 3/15/09) as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission # FF 42370 My Commission Expires August 04, 2017 Zoning Clerk • December 11, 2013 Village of Miami Shores Building and Zoning Departmeni 10050 NE 2 "d Avenue Miami Shores, Florida Attn: Building Official Re: Structural Inspection Project: Residence 950 NE 100" Street Miami Shores, Florida 33138 Dear Sir: copy On December 5, 2013 we performed a Structural Inspection of the above referenced residence building. The purpose of the inspection was to disclose the general condition of the structural elements of the existing structure and determine any deficiencies and provide recommendations for repair. The building was damaged by a fire that was concentrated in the garage enclosure of the building. The observations below and on the following pages are based on visual inspections of the building structure. GENERAL CONSTRUCTION The building structure is a one -story residential building structure that was built in 1950 and recently renovated with a new bedroom and garage addition. The building was recently completed and we understand that a CO was issued. The building structure is a concrete block and stucco building on a concrete spread footing foundation. The first floor is a concrete slab - on -grade and the roof is constructed with wood roof trusses and a barrel the shingle system. All work performed was approved by Miami Shores Village and conformed to the Approved plans and Specifications as well as the Florida Building Code in affect at the time GENERAL OBSERVATIONS The primary area of inspection was limited to the fire damaged areas of the structure which included the garage and master bathroom. We understand that there was a gas leak in the pressure valve that was attached to the water heater tank. The propane gas leak was concentrated to within the volume of the garage and additional area under the bathtub. There is an access panel to the tub from the garage wall. The propane gas was ignited and the pressure caused from the ignition blew -out the garage doors and caused tiles from the bathroom walls at the tub and water closet to fall from the wall. The flash fire only burned the 7850 NW 146TH STREE'L SUITE 509 ° MIANII i .V � J '� 1 8 _':301f;'° PHN: (305)823 -31338 ;, FAX: (305)823 -9355 December 11, 2013 Village of Miami Shores Building and Zoning Department 10050 NE 2"d Avenue Miami Shores, Florida Attn: Building Official Re: Structural Inspection Project: Residence 10666 NE 11th Avenue Miami Shores, Florida 33138 Dear Sir: On December 5, 2013 we performed a Structural Inspection of the above referenced residence building. The purpose of the inspection was to disclose the general condition of the structural elements of the existing structure and determine any deficiencies and provide recommendations for repair. The building was damaged by a fire that was concentrated in the garage enclosure of the building. The observations below and on the following pages are based on visual inspections of the building structure. GENERAL CONSTRUCTION The building structure is a one -story residential building structure that was built in 1950 and recently renovated with a new bedroom and garage addition. The building was recently completed and we understand that a CO was issued. The building structure is a concrete block and stucco building on a concrete spread footing foundation. The first floor is a concrete slab - on -grade and the roof is constructed with wood roof trusses and a barrel the shingle system. All work performed was approved by Miami Shores Village and conformed to the Approved plans and Specifications as well as the Florida Building Code in affect at the time GENERAL OBSERVATIONS The primary area of inspection was limited to the fire damaged areas of the structure which included the garage and master bathroom. We understand that there was a gas leak in the pressure valve that was attached to the water heater tank. The propane gas leak was concentrated to within the volume of the garage and additional area under the bathtub. There is an access panel to the tub from the garage wall. The propane gas was ignited and the pressure caused from the ignition blew -out the garage doors and caused tiles from the bathroom walls at the tub and water closet to fall from the wall. The flash fire only burned the 7850 Nom' 146T'H STREET. SUITE 509 IMIAM1II i k X3016 1'HN: (305)823.39 8 .. FAX: (3115)ti23 -18355 propane gas and the fire resistant interior finishes contained all flames and prevented any other ignition of materials. The following is a summary of the visual observations of the residential structure made during our inspection on December 5, 2013: A. Roof System: 1. The roof structure is a wood truss system with an attic space above the gypsum drop ceiling (over the garage), and with a built -up roof waterproof membrane roofing system and tile finish. The perimeter overhang soffit (on two sides) has attic vents along the underside. 2. We did not observe any damage either by excessive heat, fire or smoke in the attic that may have affected the wood framing. All systems are in good condition. 3. The exterior perimeter soffit vents were in good condition and we did not observe any evidence of smoke stains around the vents that occurs when fire damage may be present. B. Exterior Items: 1. We did not observe any damage to the exterior masonry walls. There were no cracks on tie beams or tie columns along the side of the building or around the garage door opening. 2. The garage doors were blown -out as result of the explosion and were destroyed. There was evidence that the metal tracks were twisted and bent but not removed. In addition, there were scrapes on the concrete wall surfaces that occurred from the movement of the doors through the opening. 3. All exterior masonry walls were in good condition. 4. The new garage doors have not been installed and are under contract for replacement. C. Interior Items: The interior damages included the following items that were not observed at the time of my inspection 7850 NW 146111 STRF.FT. SLITF. 509 MIAMI L 3300 " PlIN: (305)823-30_18 " FAV (305)823- 9355 ^" A. Several holes were created by the pressure of the explosion in the garage ceiling drywall. The drywall had been repaired but no structural or fire damage was observed during my inspection. B. The separation wall between the garage and the master bathroom had been damaged by the fire department and was repaired. C. The wall tiles in the bathtub enclosure as well as the water closet enclosure fell from the wall as a result of the concussion and were replaced. The walls we observed have suffered no structural or fire damage. RECOMMENDATIONS We recommend that all elements damaged by the flash fire be repaired or replaced. The elements would include the drop ceiling over the garage, separation wall repairs, tile replacement and garage door replacement. We will prepare Plans and Specifications that defines all areas of proposed repair in compliance with the 2010 Florida Building Code. CONCLUSIONS We conclude from our inspection that the existing building is structurally safe and sound. All repairs must be in compliance with the requirements of Miami Shores Village as well as the 2010 Florida Building Code. SUMMARY As a routine matter in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of my knowledge and ability, the report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent reasonably possible. Very trul o war dens, P.E. X50 NNk 1 -16TH ST RFI"T.' LUITE 0 01) NA � N I I L, J3016 PH N: 1305)823 -3938 FAY: (3051323 -9355 0 M . Viff�e 1 ,J�• ,t. . () enOoyed by Ws firm or me we 2. 3. 4.. i 71M 1 � of 9 t Florida. lu (8.1%2.4,2] FBC 182M2 AM U.12) 12j •° rspmmwm to pwbm Of eny cheer r8g hirde Ocensnre as a al s an pmmne! pert=ft kwedm .N " �- L i I - 2-S' 2-/7-- MIAMI SHORES VIUAGE NO -T . Tt1 ial 111 1°4 mo^ e+e•s.. o._., _ the Florida Bufid(ng Code _ (datD I am are stared or pPefeesr PROCESS N[tINBERS; Cl SPECIALwspEC•1•oR O'PUN! 11 M- CIALINSPECTOR TR11S II SPECIAL(NSPECTOR REMIF 3 SPECIAL INSPECTOR FOR f EJ SPECIAL INSPECTOR FOR t ❑ SPECIAL INSPECTOR FOR K SPECIAL INSPECTOR FOR Abb.- the nwkgd boxw apply. . the tbi Wng lndlvldual(s) ®mpl0Yed by this firm or 3. 2. 4_ o ensi, to� '� rep enakw or ammt%,+ graduation assigned ad ,� :.2nd Avenue n FlDdda 33138 795.2204 (3 05} 756.8972 , b Ian SPOW kwPeft GGrvices under On the belmh hbd Stuckowasof ad In the Stab of Fiotlda. FBG 1822.1.20 4404,8.1,2 - S A LO O HIGH 231&17.2.4.2 (R4408.8.17.2.4.2) ;ONNEC NS, FBG 22t44U8.5,2j �A9Ui , FBC 1820.3.1 tR4404.4.8.1) UN !A'LTACHN aft FBC 1827.12 (84405 8.12) ere authorized repre$entattves toperform Ins�Gtlon shall In re the authorized mPm mntafive Is qUWW by educ a lon or tram l Inspecto The qu she8 irtciude 11�nsurs as a professional SchItectural education g eating education pr In dd or en9i1eert ,graduation from an Fundsmer W npC° ; su u Ietion of the NGEES- . I. (WO) � no* iUlWW Shores VW age � inspec�r ar geneeal mar. maces.. Depeftent of any changes garding authofted personnel Pmfoaning IMPec tlon IkATF: f s 4 of KNO 1310. wed an 8h012009 t� L � L4ilYouW\ki I SCALD: 1/8" = 1• -0" INDEX COVER SHEET C-1 SITE PLAN ARCHITECTURAL A-1 PROPOSED FLOOR PLAN N.E. 99 TH ST LOCATION SKETCH LEGAL DESCRIPTION LOT 5, 8 AND 7, BLOCK 170, SECTION NO. 8 OF MIAMI SHORES, ACCORDING TO THE THEREOF, AS RECORDED IN PLAT BOOK 14, PAGE 33 OF THE PUBLIC RECORDS OF DADE COUNTY, FLORIDA. APPLICABLE CODES: FLORIDA BUILDING CODE — RESIDENTIAL. 2010 EDITION SCOPE OF WORK ALTERATION LEVEL I 1. REPLACE GARAGE DOORS SAME LOCATIONS 2. REPAIR TILE AND CEILING DRYWALL AS PER PLANS — NO PLUMBING — NO MECHANICAL — NO ELECTRICAL Edward A. LANDERS, P.E. CONSULTING IN RS s.—O fflOms —m Tel. 0305) 823 -3938 Fax (308) 823 -9355 PSETr lomwo- em VMKIM—W Wo BN MANK rtrw�ovmer wre V Z E W W� oq C7� C -1 T 1/2• GYPSUM BOARD 131 SIDES S STEEL STUDS 28 GA. 1 /g o.c J 941 sTEEL STUDS 25 OA. ® T6 0.0 SECURELY ATTACHED TO CONCRETE FLOOR AND ROOF PER FINISH SCHEDULE FLOOR (TYP) METAL STUD WALL DETAIL SCALE{ NTS PLAN LEGEND: EXISTING RESIDENCE TO REMAIN AREA OF WORK REPAIR / REPLACE TILE REPAIR DRYWALL JR DRYWALL CEILING :EVERAL AREAS D66R!i-m66RiT & TRACKS pc;, dAm SIZE DWSDIDC: WIDTH HEIGHT THICK MATERIAL TYP. I LOCATION Q 120° 84° 1 -1/4- ALUM- I ROLLER EXTERIOR Edward A. WDERS, P.E. CONSULTING ENGINEERS morwum%.m"mamn Tel. (308) 823 -3938 Fax 308 823 -9388 PSETT DWSDIDC: am R a m El fOA� n¢ mm V DA78 uj W V Z rvJr�J AI� u W C = W� � Q A -1 m�