RF-13-2495r , Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 202447 Permit Number: RF -11 -13 -2495 Scheduled Inspection Date: March 11, 2014 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: VILLAGE, MIAMI SHORES Work Classification: Repair Roof Job Address: 9825 PARK Drive Miami Shores, FL 33138 Project <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC esunamg ueparanent comments ROOF REPAIR Phone Number Parcel Number PARC2004 -19 INSPECTOR COMMENTS False jag-pector Comments Passed Failed Correction ❑ Needed vS� Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Phone: 305 - 757 -2612 March 10, 2014 For Inspections please call: (305)762 -4949 Page 4 of 38 I � 9- __ S1114 � V Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING G� JOB ADDRESS: ( � 4 Y K� �^ i -1 - -- _ -- � 145U 0 4 208 � ..BY.ed - - - - -E FBC 20 ( -2$ Permit No. ,� Master Permit No. lug l 3 .-,,, 245 ROOFING City: Miami Shores County: Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes NO OWNER: Name (Fee Simple Titleholder): PO A� c S Address- / 11 (r< !T k 0 l City: /C-4 -J Tenant/Lessee Name: Email; 6 re-7 CONTRACTOR: Company Name: Address: l City: s A o ro Qualifier Name: =XA )9k r 3 2',? State Certification or Registration #: Contact Phone # : —T2,s_- 7.2 DESIGNER: ArchitectlEngineer: t V /(4 Zone: 2,eS-7 JS"d_,�La IV State: a Zip: 3 7 f r'Y1!/ �> �- a s-!— 1 ✓1 Phone #: State: -3 1 6-e ,V O U Phone#: ( Y- L3 0 ,6 Certificate of competency #: Email Address: C eiv t uv r° o Phone #: Value of Work for this Permit: $ FP 0 Square/Linear Footage of Work: ;Z6 v Type of Work: ❑Addition Alteration n ❑New C *air/Replace ❑Demolition Description of Work: idj Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ 0.1 &4- 6 zlc ))v(- sz,_ A'�e 6 x d C/T /W A a c -41 Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC DBPR $ Bond $ _ Technology Fee $ 15c, T 7� j TOTAL FEE NOW DUE $I /,. 3(� Bonding Company's Namer(if applicable) Bonding Company's Address 0 City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtajn a t to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuan a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature Signa - Own or Agent Contractor The for9goini instrument was acknowledged before me this 5a day o0C , 20 Z2, by ��'� -� , who is person known to me or who has p oduced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) The foregoing instrument was acknowledged before me this day of V' a 20 i 3, by who is personall wn to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Miami 8hores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 November 5, 2013 Permit No: RF13 -2495 Building Critique Review BASED ON THE INFORMATION PROVIDED ON THE PERMIT APPLICATION AND ON THE ROOF SKETCH, SECTION "B ", THE ROOF MANY SECTIONS THROUGH THE ROOF ARE BEING REPAIR. ACCORDING TO SECTION R4402.10.4 NOT MORE THAN 25% OF THE TOTAL ROOF ARE OR ROOF SECTION OF ANY EXISTING BUILDING OR STRUCTURE SHALL BE REPAIR, REPLACE OR RECOVER IN ANY 12 MONTH PERIOD UNLESS THE ENTIRE ROOF SYSTEM OR ROOF SECTION IS REPLACE TO CONFORM TO THE REQUIREMENTS OF THE CODE. Ismael Naranjo } ! '5 Building Official J �/4 -RA *4,'l CQ- U C- 8q 12Z t5k kctn tz� vP�d?-,e- review is not complete, when all items above are corrected, we will do a complete as- Plan plan review.0 If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. 441) t ROOF ASSEMBLIEF AND ROOFTOP STRUCTURES Florida Building Code Edition I High- Velocity Hurricane Zone Uniform Permit App Section A (General Inform f a Master Permit No. /� Contractor's Name c/ � 0 Job Address 1 Process No. APPP T P'arl7, s U, TOC�l�9p �/� n X011 lIgN�E WITH r ALL Nryx111FSgAan — -RAL a ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE �e ; , ftng ❑ Recovering �epalrl ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) &U Steep Sloped Roof Area (SF) .2o(, Total (SF) � 6 . Section R (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. i l.� f VAce �ff l -'o-1 L% S 4l xe _( e4, s` U YL �C4 a ., .n '0" � �jr9 Vii` f 13.E -e,e-, Owner's Notification Form HVHZ 2010 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the i has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Z ne) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code; should be addressed Tasof the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida g Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring s (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or o er should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be vie ed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail pen trations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cau a water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural dis ess and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roo mg system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not ov aded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of. Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the inte of the structural assembly. (the b4ilding itself). The existing amount of attic ventilation shall not be reduc d. Exception: Attic spaces, designed by a Florida - licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's /Agent's Signature: Contractor's Signature: Property Address: Date: Permit Number: . if 7'. --- 4 --- - +A. � r MIAMI�I�14Df: MIAMI -DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miam4-Florida 33175 -2474 T,(790 315 -2590 • F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www- mlamidadegov /building[ Lamotl Roof Tile 1360 N.W. 29a' st. Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and 'regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Section and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flat Bermuda Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials; use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07-0109.01 and consists of pages 1 through S. The submitted documentation was reviewed by Alex Tigera. NOA No.:11 -0128.04 MW MlAMit E COON Expiration Date: 02/01/16 r Approval Date: 03/17/11 Page 1 of 5 t ROOFING ASSEMBLY APPROVAL Cateeorv: Roofing Sub CateuorT: Roofing Tiles Nlaterial: Concrete 1. SCOPE: This renews -a roofing system using Lamoti "Flat Bermuda ", as manufactured Lamoti Roof Tile, Inc. described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code, High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in table.2 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DzSCRIPTION: Manufactured by Test Product licant Dimensions Specifications Descriotiog Flat Bermuda Length: 16" TAS 112 Flat profile, interlocking, concrete roof Concrete Tile Width: 10" tile. For direct deck, mortar or adhesive Thickness :' /z" set applications only. Trim Pieces Length: varies TAS 112 Accessory trim, concrete roof pieces for Width: varies use at hips, rakes, ridges and valley Varying terminations. Manufactured for each tile thickness profile. 2.1 EVIDENCE SUBMTMD: Test Meng Test Identifier Test Name/Report Date Testwell Craig Laboratories & Lab #: QC-4 Static Uplift Testing May 1995 Consultants, Inc. TAS 101 (Mortar Set) IBA Consultants, Inc. 2358 -45 Static Uplift Testing 08/05/05 TAS 101 (Adhesive Set) TestweIl Craig Laboratories & Lab #: QC -7 Physical Properties May 1995 Consultants, Inc. Tech: M. Presciti TAS 112 NOA No.:11- 0128.04 Expiration Date: 02/01/16 Approval Date: 03/17/11 Page 2 of 5 3. Ul7il l ATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards lashed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION: 4.1 Lamod `Flat Bermuda Concrete Tile' and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (Ibf) Length - I (feet) Width -w (feet) Flat Bermuda Concrete Tile 7.20 1.36 1 0.84 Table 2: Aerodynamic Multipliers - ft Tile Profile )- (ft) Batten Application x (f e) Direct Deck Application Flat Bermuda Concrete Tile N/A 0.23 Table 3: Restorin g Moments due to Gravity - M ft -lb Tile 2" :12" 3" :12" 4" "•12" 5":12 " -6 "12" 7 "•12" or Profile greater Flat Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Deck Deck Deck Deck Deck Deck Concrete WA 5.56 N/A 5.49 N/A 5.39 N/A 5.24 NIA 5.03 NIA 4.77 Tile 1 1 NOA No.: 11-0128.04 M� maueCOUnr�r Expiration Date: 02/01/16 APPROVED Approval Date: 03/17/11 Page 3 of 5 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Single Patty Adhesive Set S terns Tile Profile Tile Application Minimum Attachment Resistance Flat Bermuda Concrete Tile Polyfoam Polyft rm 50.68 1 Large paddy placement of 26.7 rams of Pol ProTm. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft -Ibf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Flat Bermuda Concrete Tile Mortar Set 70.70 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". LRT FLAT BERMUDA CQNCRETE TILE LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.:11- 0128.04 u� Expiration Date: 02!01116 �WHLVA UP Approval Date: 03/17/11 Page 4 of 5 ,A�4 PROFILE DRAWING ., • . APPROVED *IF LAMOTI ROOF TILE "FLAT BERMUDA" END OF THIS ACCEPTANCE NOA No.:11- 0128.04 Expiration Date: 02/01/16 Approval Date: 03/17/11 Page 5 of 5