Loading...
RF-14-494Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 208918 Scheduled Inspection Date: March 28, 2014 Inspector: Rodriguez, Jorge Owner: PIPER, SHERYL & MARK Job Address: 1311 NE 103 Street Miami Shores, FL 33138- Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Iswiamg uepartment comments REPAIR NE TILE VALLEY (19') LEAKAGE 9" TERRACOTTA Permit Number: RF- 3- 14-494 Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1132050300110 INSPECTOR COMMENTS False Phone: 305 - 757 -2612 March 27, 2014 For Inspections please call: (305)762 -4949 Page 13 of 23 Inspector Comments Passed 10 Failed Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. March 27, 2014 For Inspections please call: (305)762 -4949 Page 13 of 23 IL r Miami Shores Village ' 01 I Building Departme 10050 N.E.2nd Avenue, Miami Shores, Flo ' 33138 Tel: (305) 795.2204 Fax: (305) 756. 972 INSPECTION'S PHONE NUMBER: (305 62.4949,& & PERMIT APPLICATION Permit Type: BUILDING FBC 20 Permit No. Master Permit No .E I (ROOFING JOB ADDRESS: 1311 NE 1 O 3 S c�'RR16y=rr City: Miami Shores County: Miami Dade Zip: ° Folio/Parcel#: a2Q Is the Building Historically Designated: Yes _ OWNER: Name (Fee Simple Titleholder):, NO ✓ Flood Zone: ,e_ fe��_ 9.) /j City: State: Tenant/Lessee Name: Phone#: Email: 1 CONTRACTOR: Company Name: �t�'�/✓�tsT ✓v ¢'i Phone#: 3&r 7,i"7 °'®d% Address: Z it A.F_ a % .Sf City: % 6 " State: �C Zip: �Z ?f � a Qualifier Name: Phone#• State Certification or Registration #: rcr ®/ &!�3 166 Certificate of Compete y #: 4200 ®® I Contact Phon T�� -a& 2, Email Address: OhLlzhl a = DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ `:2 3 T 7, 0" Square/Linear Footage of Work: I& Type of Work: ❑Addition ❑Alteration ❑New *ep.*/Rep1a je ❑Demolition Description of Work: tM Submittal Fee Scanning Fee $ Permit Fee $ Radon Fee $ CCF $ CO /CC $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ (D . 90 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. A � Signature OW4 or Agent The foregoing instrument was acknowledged before me this day of /i.Cf-/ , 20 %! , by Emialt who is personally known to me or who has produced As identification and who did take an oath. Contractor The f going instrument was acknowledged before me thi day of � 20 l by _ ,Ma D A JAA who is person l own to me or who has produced identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: E L. FULF, Sign: Print: Sk �� = rQ` %' Public t state of Prin My Commission Exp a:- commissipn # EE 849356 ,, . My Sandra e Hart �a sion FF 010644 of ��op; Bonded Though National Notarq Assn. aad� �rzc�� APPROVED BY l Plans Examiner Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Owner's Notification Form HVHZ 2010 e MAR 1 2 ®14 "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES -- REQUIRED OWNERS NOTIFICAT G CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing c or to provide the owner with the required roofing permit, and to explain to the owner the content of this...1ction. _ The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum re a 'fir n " is t, ds of the industry for roofing system installations. Additionally, the following items s es a as part of the agreement between the owner and.the contractor. The owner's initial in the d s' t d ace i dicates that the item has been explained. P 1. Aesthetics - workmanship: The workmanship provisions of C �r.16 ( e o ty Hurricane Zone) are for the purpose of providing that the roofing system meets the whin es and ter intrusion performance standards. Aesthetics (appearance) are not a °consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. P 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. o 'Q 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. _ 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of. Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida- licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's /Agent's Si€ Contractor's Signatt Property Address: Dumber: I� ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH - VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 9 Prescriptive BUR -RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concret or Cla le A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other t e, As Applicable 1,2,3,4,5,6,7 I ATTACHMENTS REQUIRED: T I. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limltations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or N Applicable, RAS 127 or RAS 126 4. Other Component of Product Approval 5. Municipal Permit Application S. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation 2010 FLORIDA BUILDING CODE — BUILDING 15.33 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. / Process No. Contractor's Name %-2c® �/ �✓� Job Address iX7 .Z.1 ROOF CATEGORY ❑ Low Slope ❑ Asphaltic Shingles ❑ New Roof ❑ Reroofing ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ Recovering ROOF SYSTEM INFORMATION / �1 Mortar /Adhesive Set Tile ❑` Wood Shingles/Shakes Repair ❑ Maintenance Low Slope Roof Area (SF) Steep I ped_Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. �-- Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.34 2010 FLORIDA BUILDING CODE -- BUILDING d a. c ROOF ASSEMBUES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof Sysl%W Roof System Manufacturer: vC c Notice of Acceptance Number: //' 6 /)- F-' 6 V Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations : 1 • �o Y-3 P2• a %d P3• r Steep Sloped Roof System Description Deck Type: Joe � Type Underlayment: L 3 R i lope: t--- :12 Insulation: Fire Barrier: Ridge V n4 lation? Fastener Type & Spacing: W --tm e N Adhesive Type: -=— -� Type Cap Sheet: ' t® Mean Roof Height: Z Roof Covering: P ses! _ ri -PV2 AA 4C-IA `A Type &Size Drip Edge: `=t i�15.36 2010 FLOR1nA Will nlMf-' rnnc _ w m nuNs f ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based Life systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf: If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P . x 1 t _414) • Mg: {o" 7 M,t f_ Product Approval Mt `�f�%�° f O (P2: (D o ° I x 10­3 Mg: J as 5 - K2 6 Product Approval Mf (P3: �e , ^x 1 t � j - Mg: �e�i I = N z/ / r fF d Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Aomoual Mr Mr required Moment Resistants" Mean Root Height —> Roof slope 15' 20' 25' W. 40' 2:12 34.4 38.5 38.2 39.7 42.2 3:12 32.2 34A 38.0 37A 39.8 4.12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.8 32.8 34.9 8:12 28.4 28.0 29.4 30.5 32.4 7:12 24A 25.9 27.1 282 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Computed the values for F with the values for Fr If the F values are greater than or equal to the Fr values. for each toes of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (Pt: x L _ x w: = - W: x cos 8 -=Fr, Product Approval I° (132: x L = x w: = _) - W: x cos B = Fr2 Product Approval F' (P3: x L = x w: = - W: x cos 8 = Fr3 Product Approval F Where to O Main Inf rm ti n Description Svmbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Tabl elorbyanenginceringanalysis prepared byPE based onASCE7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity M Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance Z= Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Ti le Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 2010 FLORIDA BUILDING CODE — BUILDING 15.37 MIAMbD�ADE MIAMI -DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miam4-Florida 33175 -2474 T. (786) 315 -2590 • F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade¢ov/buildind Lamotl Roof Tile 1360 N.W. 29h st. Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and tegulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Section and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to • revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flat Bermuda Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,' use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #07- 0109.01 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.:11- 0128.04 Expiration Date: 02101/16 Approval Date: 03/17/11 Page i of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete I. SCOPE: This renews -a roofing system using Lamoti "Flat Bermuda ", as manufactured Lamoti Roof Tile, Inc. described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code, High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in table. 2 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Suecifteations Description Flat Bermuda Length : 16" TAS 112 Flat profile, interlocking, concrete roof Concrete Tile Width: 10" tile. For direct deck, mortar or adhesive Thickness :'/2' set applications only. Trim Pieces Length: varies TAS 112 Accessory trim, concrete roof pieces for Width: varies use at hips, rakes, ridges and valley Varying terminations. Manufactured for each file thickness profile. 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Testwell Craig Laboratories & Lab #: QC -4 Static Uplift Testing May 1995 Consultants, Inc. TAS 101 (Mortar Set) IBA Consultants, Inc. 2358 -45 Static Uplift Testing 08/05/05 TAS 101 (Adhesive Set) Testwell Craig Laboratories & Lab #: QC-7 Physical Properties May 1995 Consultants, Inc. Tech: M. Presciti TAS 112 NOA NoA 1- 0128.04 Expiration Date: 02/01/16 Approval Date: 03117/11 Page 2 of 5 I LIIVIITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Ofice for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION: 4.1 Lamod `Flat Bermuda Concrete Tile' and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (VI) and Dimensions (I x w) Tile Profile Wei ht W Ib Len -I feet Width -w feet Flat Bermuda Concrete Tile 7.20 1.36 0.84 Table 2: Aerodynamic Multipliers -;L ft Tile Profile ;L (ft) Batten Application x (f e) Direct Deck Application Fiat Bermuda Concrete Tile N/A 0.23 Table 3: Restorin g Moments due to Gravity - M ft -lb Tile Profile 2 19:12" 3 11•12" 4 11•12" 6 "A r' .6 "•12" 7 11•12" or reater Flat Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Deck Deck Deck Deck Deck Deck N/A 5.56 WA 5.49 NIA 5.39 NIA 5.24 NIA 5.03 NIA 4.77 Concrete Tile 1 NOA No.: 11-0128.04 Expiration Date: 02/01/16 Approval Date: 03/17/11 Page 3 of 5 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf for Ingle ?j_q Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Application Resistance Fiat Bermuda Concrete Tile Polyfoam PolyProTm 60.68 1 Larne peddy placement of 28.7 rams of Pow row. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft -lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Flat Bermuda Concrete Tile Mortar Set 70.70 5. LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". LRT FLAT BERMUDA CONCRETE TILE LOCATED UNDERNEATH TILE 6. BUMDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.:11- 0128.04 MWMI-EMOECOUNTY Expiration Date: 02/01116 Approval Date: 03/17/11 Page 4 of 5 /;,.Is PROFILE DRAWING APPROVED .A LAMOTI ROOK TILE "FLAT BERMUDA" END OF THIS ACCEPTANCE NOA No.:11- 012 &04 Expiration Date: 02/01/16 Approval Date: 03/17/11 Page 5 of 5