Loading...
RF-14-92Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 205880 Permit Number: RF- 1 -14 -92 Scheduled Inspection Date: February 10, 2014 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: LAFFERTY, ESTHER Work Classification: Flat Job Address: 9037 NE 4 Avenue Miami Shores, FL Phone Number Parcel Number 1132060460190 Project: <NONE> Contractor: YO ROOFING AND ASSOCIATES INC Phone: (954)581-4747 Building Department Comments RE -ROOF SHINGLE INSPECTOR COMMENTS False February 07, 2014 For Inspections please call: (305)762 -4949 Page 16 of 44 Inspector Comments Passed Failed Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. February 07, 2014 For Inspections please call: (305)762 -4949 Page 16 of 44 A Miami Shores village p Building Department 14050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUII.DING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 9037 NE 4th Avenue Road JAN; 2120% FBC 20 L CD Permit No. Master Permit No. VoF ROOFING City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11- 3206 - 046 -0190 Is the Building Historically Designated: Yes NO )( Flood Zone: OWNER: Name (Fee Simple Titleholder): Esther Lafferty Phone#: Address: 9037 NE 4th Avenue Road City Miami Shores State. Florida gip. 33138 TenantUssee Name: Phone#: Email: CONTRACTOR: Company Name: Yo Roofing and Associates Phone#: 954 -581 -4747 Address: 5411 SW 25th Court City: Pembroke Park State: Florida Zip. 33023 Qualifier Name: Ron Mott Phone#. State Certification or Registration #: CCC1330049 Certificate of Competency#: Contact Phone#: Email Address: yoroofing @live.com DESIGNER: ArchitecttEngineer: Phone#: Value of Work for this Permit: $ 3,200 Square/Linear Footage of Work: 352 Type of Work: ❑Addition ❑Alteration ❑New ®Repair/Replace ❑Demolition Description of Work: Slope Tear -Off and Re -Roof Color thm tile: Submittal Fee $ Permit Fee Scanning Fee $ Radon Fee $ CCF CO /CC $ DBPR $ Bond $ Notary $ TraininWIMucation Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ BonNng Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip , Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged (Signature ` Owner or Agent The foregoing instrument was acknowledged before me this day of 070,1 , 20 1 V by ---5 ® 14 0 D t LP Q fl� , who is personally known to me io has produced L- 0 NOTARY PUBLIC: Mary Put43e State of morma Tabus Mott MY Commission EE 841189 p Exp m 10/07/2016 Sign: 04 O%A Print: My Commission Expires: APPROVED BY r /z /( L( of Signature Contractor The foregoing instrument was acknowledged before me this 49 day of -ZAN , 20 I[, by O&A11 017- , who ' ersonally known me or who has produced as identification and who did take an oath. NOTARY PUBLIC: . r,v notary Pub to State of Florida ;P Stacy Sabo*a ? y Colrimietlai EE160304 w Sign: 20M 12/01/2015 Print:. My Commission Expires: 1A -/ 1.5 Plans Examiner Zoning Structural Review Clerk (Revised 3 /12012)(Revised 07 /10107)(Revised 06110nM)(Revised 3/15/()9) TICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO TAX FOLIO NO 11- 3206 - 046 -0870 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided in this Notice of Commencement. OR Sk 28996 Ps 1532; (19s) RECORDED 01/2112014 09:43:48 HARVEY RUVINY CLERK OF COURT MIAMI -DADE COUNTY? FLORIDA LAST PAGE Space above reserved for use of recording office 1. Legal description of property and street/address: 8743 NE 4th Avenue Road Miami Shores, FL 33138 2. Description of improvement: Slope Shingle Tear -Off and Re-Roof Unit # 9037 8831 8815 3.Owner(s) name and address: Shnras Villas Condo 9743 NF dth Avenue Road Miami .Rhams FI 3313R Interest in property: Name and address of fee simple titleholder. 4. Contractor's name, address and phone number. Yo Roofing and Associates, Inc. 5411 SW 25th Court Pembroke Park FL 33023 954- 581 -4747 5. Surety: (Payment bond required by owner from contractor, If any) Name, address and phone number: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be. served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number:_ 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number 9. Expiration date of this Notice of Commencement: (the exptradon date is 1 year from the date of reording unless a diffem t dote Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. !nature(s) of Owne ( ) or O (s)' q r6�ea Officer /Director/Partner/Manager BY a� Prepared By I -Name 6 ^' Print Name Office Title/Oftice STATE OF FLOk16A COUNTY OF MIAMI -DADE The foregoing instrument was acknowledged before me this 2 � day By , ❑ Individually, or ❑ as for ❑ Personally known, orproduced the following type of Identificatio Signature of Notary Public: Print Name: f7—..utkt rn ra ="" WRIFICATION PURSUANT TO SECTION O 52.°i, F10RIOA STATUTES Noidry Pu18lo stsia at ftiaitft Under penalties of perjury, l declare that I have read the foregoing and Tobias Mott that the facts stated in It are true, to the best of my knowledge and belief. MY ConuiMisubn EE 841189 EXOM IM712016 s of Owns ) or er(s)'s Authorized Offlcer/Director/Paa S�r By U�^ By 1 hWCCER th>tt ith�tdpyf7flha tzs m sz PAeE ano f ftd to' 4 0 efla—+��d✓� of I AD. IQ.......... R �� K,f�tfffld�'OltldyC01Wf8 : {e1• 1■ wm Rernnfina " Raemprina 1 I RAE :mi e M: --------------- - - - - -- - - -- -------------------------- ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■lt ■ ■1■ ■ ■ ■t ■■ ■ ■■■■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■1 ■■■■■■■ ■V■ ■■■■■■■■■■ ■ ■I� ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■1 ■ ■ ■ ■1 ■ ■■�■■■■■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: GAF Materials Product Approval Number: 12-112703 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): P7: N/A P2: N/A P3: NIA! Maximum Design Pressure Product Approval Specific System: N/A Method of Tile Attachment: N/A Steep Sloped System Description Deck Type: Roof Slope: _3 12 Plywood Sheeting Underlayment: 30# Felt ASTM D226 Type If NA Ridge Ventilation? N/A Mean Roof Height: 20 Type & Spacing: 1 1/4" Rink Shank & 15/8" Tin Tags 16" OC Lagos 12" OC Field issive Type: NA Type Cap Sheet: NA Covering: • • • S ; • ` ; • Asa�ti 4 -. . • • .. ... .. • • • •• Type & Size Drips Edge: 3x3 r6gg • ; • .. : • . . . . Or 0:0 . . .... . .. . . • • .. . • . .. .. MIAM ti y MIAMI -DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMIMSTRATION DMSION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2594 NOTICE OF ACCEPTANCE (NOA) wim.miamidade.eov /economy GAF 1361 Alps Road. Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and /or the AHJ (in areas other than Miami Dade. County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Royal Sovereign Shingle LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA 412- 0313.11 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. tAPPROWD j . • • N @rNeR92- I1g603• • • ••• kxpJrat�n gate: #4x/18; ; Approlal bgra: 04/1§1130 • • Page 1 of 4 ••• • • • • ••• • • • •• •• • • • •• •• ••• • • • ••• • • ROOFING ASSEMBLY APPROVAL t o : Roofing Sub -Cat orv: Asphalt Shingles to 3 -Tab Deck Tm: Wood SCOPE This approves GAF Royal Sovereign® Shingle as manufactured by OAF as described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Royal Sovereign® Shingle 12" x 36" TAS 110 Fiberglas reinforced heavy weight asphalt roof shingle, with a 3-Tab profile MANUFACTURING LOCATIONS 1. Savannah, GA. 2. Tuscaloosa, AL. 3. Tampa, FL. 4. Mt Vernon, IN. S. Mobile, AL. 6. Dallas, TX. 7. Myerstown, PA. & Fontana, CA. 9. Minneapolis, MN. EVIDENCE SUBM TrM Test Agenev Test Idenfflsr Test Name/Report no Center for Applied Engineering TAS 100 02/23/94 ASTM D3462 257966 03/21/97 PRI Asphalt Technologies, Inc. TAS 100 GAF - 105-02 -01 11/14/05 TAS 100 GAF - 182-02 -01 02107/08 PRI Construction Materials Technologies, Inc. TAS 100 GAF - 332 -02 -01 01/17/12 TAS 100 GAF - 376-02 -01 10/15/12 TAS 100 GAF - 153 -02 -01 11/30/06 Underwriters Laboratories, Inc. TAS 107 OSCA48258 11/28/05 TAS 107 05CA47904 11/11/05 TAS 107 08NK02337 03/12/08 TAS 107 08NKdW •: • 1p /;o48 • • • ••. TAS 107 11 CAA 'i919 .; ;•; ;1�/O;Df'jl ASTM D 3161 / TAS 107 09CA41642 • • ' • 69128/10 " ASTM D 3161 / TAS 107 09CA38549 10/30/09 ... NANst �Z- 11�1i.'Q3� • • :.. kR*m4oH Date: • ; ; AFprojw 101P. MI/" �. Page 2 of 4 Or . • • ... . ASTM D 3462 ASTM D3462 09/12/06 ASTM D 3462 08NK02337 03/12/09 ASTM D 3462 09CA21715 05/20109 ASTM D 3462 08CA61515 07/15/09 ASTM D 3462 11 CA47919 12103/11 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. INSTALLATION I. Shingles shall be installed in compliance with Roofing Applications Standard RAS -115. 2. Flashing shall be in accordance with Roofing Applications Standard RAS -115. 3. The manufacturer shall provide clearly written application instruction. 4. Exposure and course layout shall be in compliance with Detail "A", attached. S. Nailing shall be in compliance with Detail `B ", attached. LABELING L Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved ". BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other doehments required by the Building Official or the applicable code in order to properly evaluate the installation of this system. ...... . . .. .. ........ .. . . . • foe a • . • • . . . .. ... .. . .... mprov8l'DAf�3 041180 see Page 3 of 4 . . . ... . . . . . .. 0: • . •• •• ... . . off • DETAIL A COURSE LAYOUT Drum B OVERALL Dum NSIONS AND NAILING PATTERN N END OF THIS ACCEPTANCE .. ... . . . • . • • . • NOM4:12=1126: • Expirat&n D&te: 04WAS Approval Date: 04118/13 I14• •••• ••• • • • • • • • • • • • •• •• • • • •• •• Ownees Notification Form HVHZ 2010 MIAM "Delivering Excellence Every- Day" . SECTION 1524 HIGH VELOCITY HURRJCANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the .agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained fVAestheticsworkmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. ®(2Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). (Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed I' \'kv [4, Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. [5.Tonding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural -engineer. Pondmg may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected *Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. (tVentilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of 1ttiq •vegtgatiQn §hill q9t be reduced. Exception: Attic spaces, designed by a Florida - licensed engineer or2l. i- $re'd ?4b! ct�to eliminate . ......... . the attic venting, venting shall not be required. • .. ... .. . .... Owner's/Agenfs $ Date: • / / • Permit•er. • • Contractor's Signature: - - • ••• • • • ••• • •