Loading...
RF-14-82Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 205824 Scheduled Inspection Date: March 20, 2014 Inspector: Rodriguez, Jorge Owner: PEAKE, FRANCES Job Address: 9342 NE 9 Avenue Miami Shores, FL Project: <NONE> Contractor: QUALITY ROOFING CONTRACTORS INC Building Department Comments REPAIR LEAK AT FRONT SIDE OVER GARAGE BY FLASHING. REPAIR BROKEN TILE S Permit Number: RF- 1 -14 -82 Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1132060020050 Phone: (305)953 -3333 Infractio Passed Comments INSPECTOR COMMENTS False March 19, 2014 For Inspections please call: (305)762.4949 Page 14 of 28 Inspector Comments Passed Failed Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. March 19, 2014 For Inspections please call: (305)762.4949 Page 14 of 28 v Miami Shores Village c Building Department JAN 7 2014 a90050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 JJBBY.- INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 9342 N.E. 9th Avenue FBC 20 Permit No. Master Permit No.gE AL 82— ROOFING City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel #: 11- 3206 - 002 -0050 Is the Building Historically Designated.: Yes NO X Flood Zone: OWNER: Name (Fee Simple Titleholder): Frances M. Peake Phone#: ( 305) 318 -8994 Address: 9342 N.E. 9th Avenue City: Miami Shores State. Florida 33138 Tenant/Ussee Name: Phone #: Email: CONTRACTOR: Company Name:QualitY Roofing Contractor, Inc. Phone#: ( 305) 953 -3333 Address: 13800 N.W. 1st Avenue City: Miami State: Florida Zip: 33168 Qualifier Name: Carlos Arocho Phone#: ( 786) 367 -2029 State Certification or Registration #: RC0058627 Certificate of Competency #: 000017889 Contact Phone#: ( 305) 953 -3333 Email Address: AualityroofingW@Yahoo .corn DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 2,000.00 Square/Linear Footage of Work: 1 /2sq. Type of Work: DAddition OAlteration ONew 11Repair/Replace QDemolition Description of Work: RePai r leak at front south side over garage by flashing. Repair broken tiles. Color thru tile: Submittal Fee $ ,��� Permit Fee $ L (� ` CCF $ CO /CC $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond $ Technology Fee $ - try TOTAL 1 1 iii'Vw (-Oct - Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. • As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature C 6��j -✓ Owner or Agent Contractor The foregoing instrument was acknowledged before me this 13 The foregoing instrument was acknowledged before me this day of - , 20 111 by E'Cwg e G 5 Pt r_ a. 6,e day of 20 J , by Cc 61 who is personally known to me or who has produced who is pe>jsonalown to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: �L Print: My Commission Expire APPROVED BY MY COMMISSION N FF OUNI EXPIRES: Octalw 10, 2017 ftAM 1ft N tely Nft UndwWbM Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) NOTARY PUBLIC: Sig `— Prit1: My 'Commission Expires: Beim # 10 Ow Zoning ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ... • LOW Slope • Asphaltic Shingles is Mir /Adhesive Set Tile 0 WOW ShingleWShskes R11 o e Cn o O a � @ O ° ° @ pp @ IP Lu 0 :EL j .0 t_ O 15.34 2010 FLORIDA BUILDING CODE v BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES , Florida Building Code EdWon 2010 911911- NeWa ty HWrInne Zone UnM= Pera R 4PI100on Form Section 0 - *Existing Tile 106f* Roof System Manufacturer: Boral Roofing Me. Notice ®f Acceptance Number: 12- 0308.19 Minimum calculations: ign nd Pressures, if Applicable (From RAS °127 or �.� -39.1 P2: -68.1 P3: -100.7 Deck Tom' wood 1 X 6 Type Underl*ment: 301b. Hoof Slope: ----° 12 insulation: N/A Fire Barrier: N/A Ridge Ventilation? Fastener Type & Spacing: 1 1/1 /4" R/S nails Adhesive Type: I self adherin __._..... . • \ Type Cap Sheet: I polystck TU Plus MG;n Roof Height: 13' I Roof Covering: Spanish S White tle Type & Size 3 X 3 26 GA. Drip Edge. gale. 1536 2010 FLORIDA BUILDING CODE -- BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High- Velocity Hurricane Zone Uniform Permit Application Form. Section E ('Tile Calculations) ForMoment based file systems, choose either Method 1 or2. Compare the values forMr with the values from Mp If the Mfvalues are greater than or equal to the Mr values, for each area of the roof, then the tile. attachment method is acceptable. • Method I "Moment Based Tile Calculations Per RAS 127" (Pi: _.lx X-*2M-= ..3-11) - mg: 5- = Mrt -Ida Product Approval Mf 38•% madiin Pacb'.Y (P2: ,1xX .23_" 15 M-Mg 5_93 =42 9-94 Product Approval Mf -M.% M3diM 7 (P3: 100.7x A, =Z1 a) - Mg: 5.93 = M,.3 17.53 Product Approval M f X.7 madilm Fadd•Y Method 2 "Simplified Tile Calculations Per Table Below" Reauired Moment of Resistance (M,) From Table Below Product Auroral M. Mr required Moment Resistance* Mean Roof Height Roof Slope x cos 9 20' 25' 30' 40' 2:92 34.4 36.5 38.2 39.7 42.2 3:92 32.2 34.4 36.0 37.4 39.8 4:92 30.4 32.2 33.8 $5.9 37.3 5:12 28.4 30.1 31.6 38.8 34.9 6:92 26.4 28.0 29.4 30.5 32.4 7:12 24.4 254 27.9 1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values forF' with the values fore .If die F'values are greater than orequal to the F. values, for each area of the roof, then the file attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T' (Pt:' x L = x w: _ _� - W: x cos 9 = Fri Product Approval F'- (P2: x L x w: _ __� - W: x cos 8 = F,2 Product Approval F (P3: x L = x w: _ �} - W- cos 8 - F,.y Product Approval F' - _ Where Obtain Information DescrIpMon ftmbol Where to find Design Pressure P1 or P2 or P3 RAS 127TableIorbyanengitteeringanalysispmparedbyPEbasedonASCB7 Mean Roof height H Job Site Roof Slope B Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity M9 Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions = L length W _ width Product Approval All calculations must be submitted to the building official at the time of permit application. 2010 FLORIDA BUILDING CODE - BUILDING 15.37 , to SECTION ION "02 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 44 of the Flodde Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as pare: of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. Vu11 Aesthetics -Workmanship: The workmanship provisions of Chapter 44, Section 4402 (High ci�urricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic Issues such as color or architectural appearance, that are not par, of a zoning code, should be addressed as part of the agreement between the owner and the contrac • r. 2. Renalling Wood Docks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section 84403 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system.) 3. Common Roofs: Common roofs are those which have no visible delineation between neigh bring units (I.e. townhouses, condominiums, etc.) in buildings with common roofs, the roofing Mfrom /or owner should notify the occupants of adjacent units of roofing work to be performed. xposed Cei�iings: Exposed, open beam ceilings are where the underside of the roof decking below. The owner may wish to maintain the architectural appearance, therefore, roorng n l pen trations of the underside of the decking may not be acceptable. 5. Ponding Water: The current roof system and /or deck of the building may not drain well and m y cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and perbrmance of the new roofing system. Ponding conditions may not be evident tiI the original roofing system is removed. Ponding conditions should be corrected. �• overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided, it may be necessary to install overflow scuppers in accordance with the Florida Building Code, Sections 4402, 4403 and 4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which canr suit in Qxte�dixic ,F a serario iif ,sr- - - - -.- - - -, _.. _. the roof. - _ �✓"e -� 1. � �'1✓i � / i� 1� / � � /% wne slAgent's Signature Cate Contractor's Signature Property Address Permit Number SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: - iapanbli IS' Nuevo Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 10- 0701.01 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. �°'� NOA No I2 p308.1� Fa piration Date: 05/20114 roval App Date: 06/21/12_. Page 1 of 6 HIAN MIAMI -DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/pera Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA. 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: - iapanbli IS' Nuevo Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 10- 0701.01 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. �°'� NOA No I2 p308.1� Fa piration Date: 05/20114 roval App Date: 06/21/12_. Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub - Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a system using Spanish S Nuevo Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL., and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Monier Lifetile Spanish 1= 17" TAS 112 High profile, interlocking, one - piece, 'S' shaped, 'S' Tile w = 9 -3/4" high - pressure extruded concrete roof tile equipped min. .63" thick with three nail holes. For direct deck nail -on, mortar set or adhesive set applications. Trim Pieces I = varies TAS 112 Accessory trim, concrete roof pieces for use at hips, w = varies rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. 2.1 PRODUCT DESCRIPTION 1. Lake Wales, FL. 2.2 SUBMITTED EVIDENCE: Test Aeency Test Identifier Test Name/Report Date Redland Technologies 7161 -03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) Redland Technologies 7161 -03 Wind Tunnel Testing Dec. 1991 Appendix H PA 108 (Nail -On) Redland Technologies P0647 -01 Wind Tunnel Testing Aug. 1994 PA 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied 94 -084 Static Uplift Testing May 1994 Engineering, Inc. PA 101 (Mortar Set) The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. PA 101 (Adhesive Set) The Center for Applied 25- 7183 -4 Static Uplift Testing Feb. 1995 Engineering, Inc. PA 102 (2 Quik -Drive Screws, Direct Deck) �APPRO ED I Y NOA No.: 12- 0308.19 Expiration Date: 05/20/14 Approval Date: 06/21/12 Page 2 of 6 2.2 SUBMITTED EVIDENCE: Test Ag ncl Test Identifier Test Name/Report Date The Center for Applied 25- 7214 -3 Static Uplift Testing March, 1995 Engineering, Inc. PA 102 (1 Quik -Drive Screw, Direct Deck) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC -78 PA 100 Nutting Engineering 13343.1 Physical Properties Feb 2009 TAS 112 Celotex Corporation Testing 520111 -3 Static Uplift Testing Dec. 1998 Service 520191 -2 -1 PA 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier Jan 2009 Walker Engineering, Inc. Evaluation Calculations 25 -7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25 -7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25 -7584 December 1996 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 Walker Engineering, Inc. Evaluation Calculations 25 -7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity Jan 2009 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater NOA No.: 12- 0308.19 �APPR; E Expiration Date: 05/20/14 Approval Date: 06/21/12 Page 3 of 6 4. INSTALLATION 4.1 Spanish `S' Nuevo Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (1) and Dimensions (I x w) Tile Profile Weight -W (lbf) Length -1 (ft) 1 Width -w (ft) Spanish 'S' Nuevo Tile 8.95 1.417 0.8125 Table 2: Aerodynamic Multipliers - X (f e) Tile Profile % (ft) Batten Application X (ft3) Direct Deck Application ,Spanish 'S' Nuevo Tile 0.215 0.233 Table 3: Restoring Moments due to Gravity - Mg (ft -lbf) Tile Profile 2 "•12" 3 "•12" 4 "•12" 5 "12" 6 "•12" 7 "•12" or greater Spanish 'S' Nuevo Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 1 5.36 6.00 5.33 5.93 5.21 5.83 5.09 5.70 4.96 5.56 1 4.82 5.39 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) For Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19/32" plywood) Battens Spanish 'S' Nuevo Tile 2 -10d Ring Shank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 48 Screw 20.7 20.7 18.1 2 . #8 Screws 43.2 43.2 29.8 1 -10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 19.0 1 -10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2 -10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 38.6 2 -10d Smooth or Screw Shank Nails Eave Clip) 38.1 38.1 41.8 2 -10d Ring Shank Nails 33.1 48.1 45.2 1 Installation with a 4" tile headlap and fasteners are located a min. of 2'/° from head of tile. MIAMI•DADE COUNTY NOA No.: 12- 0308.19 JAPPROVEDI Expiration Date: 05/20/14 Approval Date: 06/21/12 Page 4 of 6 Table 6: Attachment Resistance Expressed as a Moment Mf (ft -lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Spanish 'S' Nuevo Tile Adhesive 29.3 2 See manufactures component approval for installation requirements. 3 Flexible Products Company Tilel3ond Average weight per patty 10.7 grams. 3MTm 2 -Com ponent Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Spanish 'S' Nuevo Tile 3M 2- Component Foam Roof Tile Adhesive AH -160 66.5 3M 2- Component Foam Roof Tile Adhesive AH -160 3$, 4 Large paddy placement of 63 rams of 3M 2-Com onent Foam Roof Tile Adhesive AH -160. 4 Medium paddy placement of 24 rams of 3M""2-Component Foam Roof Tile Adhesive AH -160. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft -lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Spanish 'S' Nuevo Tile Mortar Setb 24.5 5 Tile -Tite Roof Tile Mortar. 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". BORAL ROOFING LLC SPANISH'S' NUEVO CONCRETE ROOF TILE (LAKE WALES, FL.) (LOCATED ON UNDERSIDE OF TILE) NOA No.: 12- 0308.19 Expiration Date: 05/20/14 Approval Date: 06/21/12 Page 5 of 6 0 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. xs�lls PROFILE DRAWINGS "*�X -*�< - -- SPANISH `S' NUEVO CONCRETE ROOF TILE (POMPANO BEACH, FL.) END OF THIS ACCEPTANCE If NOA No.: 12- 0308.19 APPROVED Expiration Date: 05/20/14 Approval Date: 06/21/12 Page 6 of 6