RF-14-82Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 205824
Scheduled Inspection Date: March 20, 2014
Inspector: Rodriguez, Jorge
Owner: PEAKE, FRANCES
Job Address: 9342 NE 9 Avenue
Miami Shores, FL
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Building Department Comments
REPAIR LEAK AT FRONT SIDE OVER GARAGE BY
FLASHING.
REPAIR BROKEN TILE S
Permit Number: RF- 1 -14 -82
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Repair Roof
Phone Number
Parcel Number
1132060020050
Phone: (305)953 -3333
Infractio Passed Comments
INSPECTOR COMMENTS False
March 19, 2014 For Inspections please call: (305)762.4949 Page 14 of 28
Inspector Comments
Passed
Failed
Correction
Needed ❑
Re- Inspection ❑
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
March 19, 2014 For Inspections please call: (305)762.4949 Page 14 of 28
v
Miami Shores Village c
Building Department JAN 7 2014
a90050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972 JJBBY.-
INSPECTION'S PHONE NUMBER: (305) 762.4949
BUILDING
PERMIT APPLICATION
Permit Type: BUILDING
JOB ADDRESS: 9342 N.E. 9th Avenue
FBC 20
Permit No.
Master Permit No.gE AL 82—
ROOFING
City: Miami Shores County: Miami Dade Zip: 33138
Folio/Parcel #: 11- 3206 - 002 -0050
Is the Building Historically Designated.: Yes
NO X Flood Zone:
OWNER: Name (Fee Simple Titleholder): Frances M. Peake Phone#: ( 305) 318 -8994
Address: 9342 N.E. 9th Avenue
City: Miami Shores State. Florida 33138
Tenant/Ussee Name: Phone #:
Email:
CONTRACTOR: Company Name:QualitY Roofing Contractor, Inc. Phone#: ( 305) 953 -3333
Address: 13800 N.W. 1st Avenue
City: Miami State: Florida Zip: 33168
Qualifier Name: Carlos Arocho Phone#: ( 786) 367 -2029
State Certification or Registration #: RC0058627 Certificate of Competency #: 000017889
Contact Phone#: ( 305) 953 -3333 Email Address: AualityroofingW@Yahoo .corn
DESIGNER: Architect/Engineer: Phone#:
Value of Work for this Permit: $ 2,000.00 Square/Linear Footage of Work: 1 /2sq.
Type of Work: DAddition OAlteration ONew 11Repair/Replace QDemolition
Description of Work: RePai r leak at front south side over garage by flashing.
Repair broken tiles.
Color thru tile:
Submittal Fee $ ,��� Permit Fee $ L (� ` CCF $ CO /CC $
Scanning Fee $
Radon Fee $
Notary $ Training/Education Fee $
Double Fee $ Structural Review $
DBPR $ Bond $
Technology Fee $
- try
TOTAL 1 1 iii'Vw
(-Oct -
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
zip
zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant. • As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signature C 6��j -✓
Owner or Agent Contractor
The foregoing instrument was acknowledged before me this 13 The foregoing instrument was acknowledged before me this
day of - , 20 111 by E'Cwg e G 5 Pt r_ a. 6,e day of 20 J , by Cc 61
who is personally known to me or who has produced who is pe>jsonalown to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC:
Sign: �L
Print:
My Commission Expire
APPROVED BY
MY COMMISSION N FF OUNI
EXPIRES: Octalw 10, 2017
ftAM 1ft N tely Nft UndwWbM
Plans Examiner
Structural Review
(Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09)
NOTARY PUBLIC:
Sig `—
Prit1:
My 'Commission Expires:
Beim #
10 Ow
Zoning
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ...
• LOW Slope
• Asphaltic Shingles
is Mir /Adhesive Set Tile
0 WOW ShingleWShskes
R11 o
e
Cn
o
O
a �
@
O
°
°
@
pp
@
IP
Lu
0
:EL
j
.0 t_
O
15.34
2010 FLORIDA BUILDING CODE v BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ,
Florida Building Code EdWon 2010
911911- NeWa ty HWrInne Zone UnM= Pera R 4PI100on Form
Section 0 - *Existing Tile 106f*
Roof System Manufacturer: Boral Roofing Me.
Notice ®f Acceptance Number: 12- 0308.19
Minimum calculations: ign nd Pressures, if Applicable (From RAS °127 or
�.� -39.1 P2: -68.1 P3: -100.7
Deck Tom' wood 1 X 6
Type Underl*ment: 301b.
Hoof Slope:
----° 12 insulation: N/A
Fire Barrier: N/A
Ridge Ventilation? Fastener Type & Spacing: 1 1/1 /4" R/S nails
Adhesive Type: I self adherin
__._..... . • \ Type Cap Sheet: I polystck TU Plus
MG;n Roof Height: 13' I Roof Covering: Spanish S White tle
Type & Size 3 X 3 26 GA.
Drip Edge. gale.
1536 2010 FLORIDA BUILDING CODE -- BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
High- Velocity Hurricane Zone Uniform Permit Application Form.
Section E ('Tile Calculations)
ForMoment based file systems, choose either Method 1 or2. Compare the values forMr with the values from Mp If the Mfvalues are greater than or
equal to the Mr values, for each area of the roof, then the tile. attachment method is acceptable. •
Method I "Moment Based Tile Calculations Per RAS 127"
(Pi: _.lx X-*2M-= ..3-11) - mg: 5- = Mrt -Ida Product Approval Mf 38•% madiin Pacb'.Y
(P2: ,1xX .23_" 15 M-Mg 5_93 =42 9-94 Product Approval Mf -M.% M3diM 7
(P3: 100.7x A, =Z1 a) - Mg: 5.93 = M,.3 17.53 Product Approval M f X.7 madilm Fadd•Y
Method 2 "Simplified Tile Calculations Per Table Below"
Reauired Moment of Resistance (M,) From Table Below Product Auroral M.
Mr required Moment Resistance*
Mean Roof Height
Roof Slope
x cos 9
20'
25'
30'
40'
2:92
34.4
36.5
38.2
39.7
42.2
3:92
32.2
34.4
36.0
37.4
39.8
4:92
30.4
32.2
33.8
$5.9
37.3
5:12
28.4
30.1
31.6
38.8
34.9
6:92
26.4
28.0
29.4
30.5
32.4
7:12
24.4
254
27.9
1 28.2
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals.
For Uplift based tile systems use Method 3. Compared the values forF' with the values fore .If die F'values are greater than orequal to the F. values,
for each area of the roof, then the file attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T'
(Pt:' x L
= x w: _ _� - W:
x cos 9
= Fri
Product Approval F'-
(P2: x L
x w: _ __� - W:
x cos 8
= F,2
Product Approval F
(P3: x L
= x w: _ �} - W-
cos 8
- F,.y
Product Approval F' - _
Where
Obtain Information
DescrIpMon
ftmbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127TableIorbyanengitteeringanalysispmparedbyPEbasedonASCB7
Mean Roof height
H
Job Site
Roof Slope
B
Job Site
Aerodynamic Multiplier
x
Product Approval
Restoring Moment due to Gravity
M9
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
=
L length W _ width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
2010 FLORIDA BUILDING CODE - BUILDING 15.37
, to
SECTION ION "02
HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of this section. The provisions of
Chapter 44 of the Flodde Building Code, Building govern the minimum requirements and standards of the
industry for roofing system installations. Additionally, the following items should be addressed as pare: of the
agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the
item has been explained.
Vu11 Aesthetics -Workmanship: The workmanship provisions of Chapter 44, Section 4402 (High
ci�urricane Zone) are for the purpose of providing that the roofing system meets the wind resistance
and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with
respect to workmanship provisions. Aesthetic Issues such as color or architectural appearance, that are
not par, of a zoning code, should be addressed as part of the agreement between the owner and the
contrac • r.
2. Renalling Wood Docks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section 84403 (High Velocity Hurricane Zones) of the
Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system.)
3. Common Roofs: Common roofs are those which have no visible delineation between
neigh bring units (I.e. townhouses, condominiums, etc.) in buildings with common roofs, the roofing
Mfrom /or owner should notify the occupants of adjacent units of roofing work to be performed.
xposed Cei�iings: Exposed, open beam ceilings are where the underside of the roof decking
below. The owner may wish to maintain the architectural appearance, therefore, roorng
n l pen trations of the underside of the decking may not be acceptable.
5. Ponding Water: The current roof system and /or deck of the building may not drain well and
m y cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of
structural distress and may require the review of a professional structural engineer. Ponding may shorten
the life expectancy and perbrmance of the new roofing system. Ponding conditions may not be evident
tiI the original roofing system is removed. Ponding conditions should be corrected.
�• overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge
if overflow scuppers (wall outlets) are not provided, it may be necessary to install overflow scuppers in
accordance with the Florida Building Code, Sections 4402, 4403 and 4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which canr suit in Qxte�dixic ,F a serario iif ,sr- - - - -.- - - -,
_.. _.
the roof. - _
�✓"e -� 1. � �'1✓i � / i� 1� / � � /%
wne slAgent's Signature Cate Contractor's Signature
Property Address Permit Number
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: - iapanbli IS' Nuevo Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 10- 0701.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
�°'� NOA No I2 p308.1�
Fa piration Date: 05/20114
roval
App Date: 06/21/12_.
Page 1 of 6
HIAN
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/pera
Boral Roofing LLC.
7575 Irvine Center Drive, Suite 100
Irvine, CA. 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: - iapanbli IS' Nuevo Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 10- 0701.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
�°'� NOA No I2 p308.1�
Fa piration Date: 05/20114
roval
App Date: 06/21/12_.
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub - Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a system using Spanish S Nuevo Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake
Wales, FL., and described this Notice of Acceptance.
For locations where the pressure requirements, as
determined by applicable Building Code does not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in the installation
section herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test
Product
Applicant Dimensions Specifications
Description
Monier Lifetile Spanish 1= 17" TAS 112
High profile, interlocking, one - piece, 'S' shaped,
'S' Tile w = 9 -3/4"
high - pressure extruded concrete roof tile equipped
min. .63" thick
with three nail holes. For direct deck nail -on,
mortar set or adhesive set applications.
Trim Pieces I = varies TAS 112
Accessory trim, concrete roof pieces for use at hips,
w = varies
rakes, ridges and valley terminations.
varying thickness
Manufactured for each tile profile.
2.1 PRODUCT DESCRIPTION
1. Lake Wales, FL.
2.2 SUBMITTED EVIDENCE:
Test Aeency Test Identifier
Test Name/Report Date
Redland Technologies 7161 -03
Static Uplift Testing Dec. 1991
Appendix III
PA 102 & PA 102(A)
Redland Technologies 7161 -03
Wind Tunnel Testing Dec. 1991
Appendix H
PA 108 (Nail -On)
Redland Technologies P0647 -01
Wind Tunnel Testing Aug. 1994
PA 108 (Mortar Set)
Redland Technologies P0402
Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
The Center for Applied 94 -084
Static Uplift Testing May 1994
Engineering, Inc.
PA 101 (Mortar Set)
The Center for Applied 94-083
Static Uplift Testing April 1994
Engineering, Inc.
PA 101 (Adhesive Set)
The Center for Applied 25- 7183 -4
Static Uplift Testing Feb. 1995
Engineering, Inc.
PA 102 (2 Quik -Drive Screws,
Direct Deck)
�APPRO ED I Y
NOA No.: 12- 0308.19
Expiration Date: 05/20/14
Approval Date: 06/21/12
Page 2 of 6
2.2 SUBMITTED EVIDENCE:
Test Ag ncl
Test Identifier
Test Name/Report
Date
The Center for Applied
25- 7214 -3
Static Uplift Testing
March, 1995
Engineering, Inc.
PA 102 (1 Quik -Drive Screw,
Direct Deck)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
PA 108 (Nail -On)
The Center for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering, Inc.
Test #MDC -78
PA 100
Nutting Engineering
13343.1
Physical Properties
Feb 2009
TAS 112
Celotex Corporation Testing
520111 -3
Static Uplift Testing
Dec. 1998
Service
520191 -2 -1
PA 101
March 1999
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
Jan 2009
Walker Engineering, Inc.
Evaluation Calculations
25 -7094
February 1996
Walker Engineering, Inc.
Evaluation Calculations
25 -7496
April 1996
Walker Engineering, Inc.
Evaluation Calculations
25 -7584
December 1996
25- 7804b -8
25- 7804 -4 & 5
25- 7848 -6
Walker Engineering, Inc.
Evaluation Calculations
25 -7183
March 1995
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moment Due to Gravity
Jan 2009
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set System
April 1999
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater
NOA No.: 12- 0308.19
�APPR; E Expiration Date: 05/20/14
Approval Date: 06/21/12
Page 3 of 6
4. INSTALLATION
4.1 Spanish `S' Nuevo Concrete Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (1) and Dimensions (I x w)
Tile Profile
Weight -W (lbf)
Length -1 (ft)
1
Width -w (ft)
Spanish 'S' Nuevo Tile
8.95
1.417
0.8125
Table 2: Aerodynamic Multipliers - X (f e)
Tile
Profile
% (ft)
Batten Application
X (ft3)
Direct Deck Application
,Spanish 'S' Nuevo Tile
0.215
0.233
Table 3: Restoring Moments due to Gravity - Mg (ft -lbf)
Tile
Profile
2 "•12"
3 "•12"
4 "•12"
5 "12"
6 "•12"
7 "•12" or
greater
Spanish
'S' Nuevo
Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
1 5.36
6.00
5.33
5.93
5.21
5.83
5.09
5.70
4.96
5.56
1 4.82
5.39
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf)
For Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15132"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Spanish 'S'
Nuevo Tile
2 -10d Ring Shank Nails
28.6
41.2
19.4
1 -10d Smooth or Screw Shank Nail
5.1
6.8
2.8
2 -10d Smooth or Screw Shank Nails
6.9
9.2
7.3
1 48 Screw
20.7
20.7
18.1
2 . #8 Screws
43.2
43.2
29.8
1 -10d Smooth or Screw Shank Nail
Field Clip)
23.1
23.1
19.0
1 -10d Smooth or Screw Shank Nail
Eave Clip)
29.3
29.3
24.0
2 -10d Smooth or Screw Shank Nails
Field Clip)
27.6
27.6
38.6
2 -10d Smooth or Screw Shank Nails
Eave Clip)
38.1
38.1
41.8
2 -10d Ring Shank Nails
33.1
48.1
45.2
1 Installation with a 4" tile headlap and fasteners are located a min. of 2'/° from head of tile.
MIAMI•DADE COUNTY
NOA No.: 12- 0308.19
JAPPROVEDI Expiration Date: 05/20/14
Approval Date: 06/21/12
Page 4 of 6
Table 6: Attachment Resistance Expressed as a Moment Mf (ft -lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Spanish 'S' Nuevo Tile
Adhesive
29.3
2 See manufactures component approval for installation requirements.
3 Flexible Products Company Tilel3ond Average weight per patty 10.7 grams.
3MTm 2 -Com ponent Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams.
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Spanish 'S' Nuevo Tile
3M 2- Component Foam Roof Tile Adhesive AH -160
66.5
3M 2- Component Foam Roof Tile Adhesive AH -160
3$,
4 Large paddy placement of
63 rams of 3M 2-Com onent Foam Roof Tile Adhesive AH -160.
4 Medium paddy placement of 24 rams of 3M""2-Component Foam Roof Tile Adhesive AH -160.
Table 8: Attachment Resistance Expressed as a Moment - Mf(ft -lbf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Spanish 'S' Nuevo Tile
Mortar Setb
24.5
5 Tile -Tite Roof Tile Mortar.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail
Below), or following statement: "Miami -Dade County Product Control Approved ".
BORAL ROOFING LLC SPANISH'S' NUEVO CONCRETE ROOF TILE (LAKE WALES, FL.)
(LOCATED ON UNDERSIDE OF TILE)
NOA No.: 12- 0308.19
Expiration Date: 05/20/14
Approval Date: 06/21/12
Page 5 of 6
0
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
xs�lls
PROFILE DRAWINGS
"*�X -*�< - --
SPANISH `S' NUEVO CONCRETE ROOF TILE (POMPANO BEACH, FL.)
END OF THIS ACCEPTANCE
If
NOA No.: 12- 0308.19
APPROVED Expiration Date: 05/20/14
Approval Date: 06/21/12