Loading...
MC-14-206Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 206596 Scheduled Inspection Date: March 19, 2014 Inspector: Perez, JanPierre Owner: QUINTANA, ALEXANDER Job Address: 1045 NE 97 Street Miami Shores, FL Project: <NONE> Contractor: EDD HELMS AIR CONDITIONING AND ELECTRIC Permit Number: MC -2 -14 -206 Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132050170100 Phone: (305)653 -2530 auiIming Department comments REPLACE 4 TON SPLIT SYSTEM Infractio Passed Comments INSPECTOR COMMENTS False March 18, 2014 For Inspections please call: (305)762.4949 Page 19 of 51 Inspector Comments d Passed In Failed Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. March 18, 2014 For Inspections please call: (305)762.4949 Page 19 of 51 ml- LLA ,� Miami Shores Vill APPnovED1 BY ZONING DEPT BLDG DEPT DATE SUBJECT TO COMPLIANCE 1M* ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS FEB 0 410% Miami Shores ' Vi�i l age AIR CONDITIONING REPLACEMENT DATA Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel. (305) 795.2204 Fan. (305) 756.8972 PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. c Job Address (where the work Is being done): ( Li � � � ql ski City: Miami Shores Village County: Miami Dade Zip Code: t� ENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS y > Q 5 ARI (AHRI) DATA SHEET REQUIRED A IN means: YES ❑ NO ARHI Sheet Attached: YES NO ❑ Contract Attached: YES 1. 2. Minimum Circuit Ampacity (Wire Size): 3x to Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: State Certificate or Registration N. 6 6 "-q ( - S0q Certificate of Competency Phone: 30S 03 2 S.3 Signature Date: 743IJ4 (Quelffler's signature only) UN11WING REPLACED DATA NEW UNIT 1 2e4 0 14 MANUFACTURER T 4 'WF air AHU or PKG. UNIT MODEL # COND. UNIT MODEL # O KW HEAT NOM TONS AHU ®CU PKG 1 M.C.A AHU CU PKG AHU 60 CU PKG 2 MAP AHU66 CUqt5 PKG AHU CU PKG 3 VOLTS AHU CU PKG PKG UNIT I I PKG UNIT EER/SEER YES NO REPLACING DUCTS S YES NO REPLACING THERMOSTAT ES NO YES NO NEW 4 °CONCRETE SLAB YES YES NO NEW ROOF STAND YES YES NO NEW RETURN PLENUM BOX YES NO Minimum Circuit Ampacity (Wire Size): 3x to Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: State Certificate or Registration N. 6 6 "-q ( - S0q Certificate of Competency Phone: 30S 03 2 S.3 Signature Date: 743IJ4 (Quelffler's signature only) ilrtip 't" AHRI Certified Reference Number: 5886249 Date: 1/30/2014 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 4TTB6049A1 Indoor Unit Model Number: *AM7AOC48H41 Manufacturer: TRANE Trade/Brand name: XB16 Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows In accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, Independent, third party testing: Cooling Capacity (Btuh): 46500 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16.00 IEER Rating (Cooling): * Ratings followed by an asterisk (h Indicate a voluntary remle of previously published data, unless accompanied with a WAS, which Indicates an involuntary rerate. 02013 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130355888334371046 Load Short Form Job: 1045 Date: January 30 2014 Entire House By: Edd Helms Air Conditioning 17850 NE 5thAvenue, Miand, Fl 33162 Phone: 305 -65 3-2530 Uoense: CACO21309 h �> For Alex Qunitana 1045 NE 97th Street, Miami Shores, i HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat COOLING EQUIPMENT Area Make Trane Btuh Htg Clg Infiltration Outside db ( °F) 51 90 Method Simplified Inside db ( °F) 70 75 Construction quality Average Design TD ( °F) 20 15 Fireplaces 0 Daily range - L Inside humidity ( %) 30 50 Moisture difference (gr /lb) -11 57 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat COOLING EQUIPMENT 16 SEER Area Make Trane Btuh 13950 Trade XB16 46500 Btuh Cond 4TTB6049E1 cfm 0.046 Coil *AM7AOC48H41 0 in H2O AHRI ref 5886249 100 EFF 1583 Efficiency 13.0 EER, 12.2 kW Sensible cooling 41657 Btuh Latent cooling 24 OF Total cooling 1583 cfm Actual air flow 0.050 cfm/Btuh Air flow factor 0 in H2O Static pressure Latent cooling Load sensible heat ratio 16 SEER Area 32550 Btuh 13950 Btuh 46500 Btuh 1583 cfm 0.046 cfm/Btuh 0 in H2O 0.88 34373 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Room1 2056 31566 34373 1583 1583 Entire House d 2056 31566 34373 1583 1583 Other equip loads 0 0 Equip. @ 0.95 RSM 32792 Latent cooling 4693 TnTAIC 7AGC OAGGG 97A OG AGOO AGOO J 1 uuu J r -tu:l I UAJ I JOJ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2014- .Ian- 3016A5 06 L Azxwrightsoft• RlghtSubo unWrsal 201212.1.08 RSU07042 Page 1 ..Atsott WACVUex QuIntara 16 Seer T B 4 ton.rup Calc = MJ8 Front Door faces: S Project Summary Entire House Edd Helms Air Conditioning 17850 NE 5thAvenue, Mard, F1 33162 Phone: 305-653-2530 .0 f'ro ect l,lntormafiion ; For Alex Qunitana 1045 NE 97th Street, Miami Shores, Fl. 33138 Notes: �- �D'esign [6 Or, rrhafIon a Weather. Winter Design Conditions Outside db 51 OF Inside db 70 OF Design TD 20 OF Heating Summary 0.32 0.16 Structure 25073 Btuh Ducts 6492 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 31566 Btuh Infiltration Miami, FL, US Method Simplified Construction quality Average Fireplaces 0 Heating Equipment Summary Job: 1045 Date: January 30 2014 By: Summer Design Conditions Heating Cooling Area (ft2) 0.95 32792 2056 Volume (ft3) 16448 16448 Air changes /hour 0.32 0.16 Equiv. AVF (cfm) 88 44 Heating Equipment Summary Job: 1045 Date: January 30 2014 By: Summer Design Conditions Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 75 15 L 50 57 OF OF OF % gr /lb Sensible Cooling Equipment Load Sizing Structure 22903 Btuh Ducts 11470 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Ratetswing multiplier Equipment sensible load 0.95 32792 Btuh Latent Cooling Equipment Load Sizing Structure 1694 Btuh Ducts 2999 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 4693 Btuh Equipment total load 37485 Btuh Req. total capacity at 0.70 SHR 3.9 ton Cooling Equipment Summary Make Make Trane Trade Trade XB16 Model Cond 4TTB6049E1 AHRI ref Coil *AM7AOC48H41 AHRI ref 5886249 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.2 kW Sensible cooling 32550 Btuh Heating output 41657 Btuh Latent cooling 13950 Btuh Temperature rise 24 OF Total cooling 46500 Btuh Actual air flow 1583 cfm Actual air flow 1583 cfm Air flow factor 0.050 cfm /Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. writ htsoftm 2014- Jan - 3016:05:08 g Right- S.PlSS UIIWMai 201212.1.06 RSU07042 Page 1 ... hiwltWACWiexQuintara16 Seer TrB4ton .rup Caic =M18 Front Door faces: S Right -JO Worksheet Job: 1045 Entire House Date: January 30 2014 Edd Helms Air Conditioning By: 17850 NE 5thAvenue, Maud, F1 33162 Phone: 305-6553 -2530 License: CACD21309 1 Room name Entire House Rown1 2 Exposed wall 202-4 It 202.4 ft 3 Room Fight 8.0 It d 8.0 ft heat/cool 4 Rowe dimensions 1.0 x 2058.0 ft 5 Room area 2056.0 ft' 2056.0 ft2 Ty t ion U -value Or Area °F) or perimeter (ft) e (Btuh) t�(Btuhft? or perimeer (ft) (Btuh) Heat Ccol Gross N/P /S Heat Cool Gross N/P /S Heat Cool 6 W 13A4-Doc 0.584 n 11.39 12-73 312 312 3553 3972 312 342 3653 3972 w 13AA -Doc 0.584 a 11.39 12.73 488 488 W57 6213 488 488 5557 6213 1N I—C' 13AA -Ooc 0.584 a 11.39 12.73 328 319 3633 1 328 319 3633 4061 1Ac1om 1.270 a 24.78 38.39 9 0 223 345 9 0' 2233 345 w 11 13MmOoc 0.584 w 11.39 12.73 456 456 5193 5805 456 456 5193 5805 w 13AA -Ooc 0.584 rrw 11.39 12.73 36 36 407 465 36 38 407 455' C 16D-Md 0.018 - 0.35 0.62 2058 2056 722 1273 2058 20.56 722 1273 F 220-tpi 0.989 - 19.29 0.00 2056 202 3904 0 2058 202 3904'' 0 61 c) AED excursion 35 1 35 Envelope loss/gain 23192 22160 23192 22160 12 a) Infiltration 1881 743 1881 743 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 25073 22903 25073 22903 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 25073 22903 25073 22903 1 5 Duct loads 28 6% 50%1 6492 11470 26% 500/6 6492 11470 Total room load 31566 34373 31566 34373 Air required (cfm) 1583 1583 1583 1583 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrighttzsotit° 2014 -Jan- 3018:05:06 RightSuite® Unh ersel 2012 12.1.06 RSU07042 Page 1 A ...htsoft HVACAAIex Quintero 16 Seer TTB 4 ton.rup Calc= W8 Front Door faces: S Miami Shores Village Building Department 90050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 RECEIVED FEB 0 4 2014 ", PsE FBC 20 LC:) BUILDING Permit No. PERMIT APPLICATION Master Permit No MC- y r i Permit Type: MECHANICAL JOB ADDRESS: /0 11 AJ6 q-7 City: Miami Shores County: Miami Dade Zip: Folio)Parcel #: // 3e9as-_ 0/7— C9/00 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Sim )le Titleholder): Ala u r n -k d' V9' Phone#: Address- ®4 57 /k, � �& City: arl 6 @h° S State P Tenant/Lessee Name: Phone#: Email: ab 4elvK-s (4td -s 2s �✓ CONTRACTOR: Company Name: Phone#: c����3 Address: City: State: Zip: R/ LO Qualifier Name: =r`J Pavan f�`/�`L "-e—R Phone#: - asaO O State Certification or Registration #: j! +d✓2_1 305 Certificate of Competency #: Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Ik et =7 oc-/ Phone#: V Value of Work for this Permit: $ C-- f vvv SquardLinear Footage of Work: Type of Work: ❑Address OAlteration ONew air/Replace ODemolition Description of Work: t Submittal Fee $ Permit Fee Scanning Fee $ Notary $ Radon Fee $ CCF $ CO /CC $ DBPR $ Bond Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FF,F, NOW DUF. $ 2�y A Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occ s even (plays after the building permit is issued In the absence of such posted notice, the inspection will not ap roved reins fee will be charged. Signa Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this---k- day of �_, 2d�L, by ) f, DO) ^4Q ;O; day of , 20 t, by who is personally known to me or who has produced FL DJJ wh who has produced As identification and who did take an oath. Q111111 t- `4;Iilt _im 19 Sign: I -V CUxP Print: My Commission APPROVED BY D Nit Putillo • State of Florida W1 ell q* '1t Nov 7, 2017 Cop • FF 55651 Examiner identification and who did take an oath. NOTARY PUBLIC: Sign: q j'1 ..� .r , •c's MU Print: • • Sf'+ MR My Commi off' OOmnF►t' # FF 55691 Zoning Structural Review Clerk Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06110/2009)(Rmised 3/15/09) January i 9 Alex Quir tana 1045 NE 7th Street Miami Sh res, Fl. 33138 305 -761 -3 883, E -mail: alexquintana @bellsouth.net Edd Helm Air Conditioning is pleased to provide this proposal to replace the air conditioning in your home i 1. P4rmit 2. R$moval and disposal of the existing equipment 3. In tall New 16 Seer System wlil:h Variable Speed Air Handler 4. H ater 5. N w Safety Overflow Switch 6. N w Digital Programmable Totich Screen Thermostats 7. T mper Proof Refrigerant Cap per Code 8. H rricane Clips per Code 9. R connect to the duct work, copper lines, drainage systems and electrical service 10. C arge systems with 410A refrigerant and Start up the systems and check the operation Trane equipment: Condenser Moded: 4TTB6049A, Air Handler: TAM7AOC48 Total for a system above: $ 5,780.00 - $ 780.00 FPL Rebate = $ 5,000.00 Terms: $ ,500.00 down and $ 2,500.00 upon start up of new system. Warranty: 10ne Year Labor and Ten Years all Parts. Customer must register system with In 45 days of the installatio at www.tmne.com or parts warranty will revert to five years. Edd Helms A accordance v The HVAC sl does not inch you suspects actions outsic responsible fi direct to Edd Conditioning is authorized to perform the above work and services at the prices and terms specified herein. All payments shall be due in th the terms described above. Custoner agrees to pay all court costs and attorneys fees should legal mean be necessary for collection. item included in this proposal is designed according to industry standards to provide comfort cooling in occupied areas. This proposal ie the responsibility by EDD HELMS `or any procedures to identify, control, eliminate or remove mold In occupied or unoccupied spaces. If old to be a problem, or If you have construction conditions that support the growth of mold, we recommend the CUSTOMER take remedial of this proposal to eliminate the problem, remove the mold, and insure a mold free environment. Edd Helms Air Conditioning shall not be drywall repairs, painting, concrete repairs, or code violations outside of the scope of work. All cancellations must be submitted in writing [elms Group, Inc. three business day:: before verbal schedule installation date. N.E. 5th Avenue. Miami, Florida 33162. Tel: 305- 653 -2530. Toll Free: (800) 329 -2530. Fax: (305) 653 -7933 www.eddheims.com Page 1 s CAC Ed He? Y EC 130001830183 0 Air Conditioning & Electric A Name You Can Trust Since 1975 MOLD AN ISSUES RELATED TO IND13OR AIR QUALITY. This contract does not include the responsibility by Edd Helms for any procedures to dentify, control, eliminate or remove rnold or mildew in any HVAC systems or equipment. If you suspect mold or mildew to be a problem, or if you have nstruction conditions that support the growth of mold or mildew, we recommend the CUSTOMER take remedial actions outside of this proposal to oily iinate the problem, remedy the construction conditions, remove the mold or mildew, and insure a mold free environment. i If you have any questions concerning this proposal, convenie ce. We tha4 you for this opportunity to be of service. i Sincerely,) Ron Th mpson Comfort pecialist Cell: 305- 70 -4711 please do not hesitate to contact us at your r � Customr S at I Date APPROVED ZONING DEPT BLDG DEPT I Y DATE ALL FEDERAL SUBJECT TO C()MrUP%1N- - ..... - STATE AND COUNTY RULES AND REGULATIONS FE® 04 014 iami Shores Village Building Department AIR CONDITIONING REPLACEMENT DATA 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel. (305) 795.2204 Fax. (305) 756.8972 PERMIT NUMBER: MC air conditioning replacement permit applications. Each unit change -out must be on its own data _ is are not acceptable. Job Address (where the work Is being done): L S �j City: MIR II un a Zip Code: 3�d A N S T BE ON A 4 INCH SOLID CONCRETE SLAB LL T LY WITH F.E.M.A MINIMUM FLOOD ELEVATION T NTRACT IS REQUIRED WITH ALL SUBMITALS (AHRI) DATA SHEET REQUIRED Change Discon ARHI Sheet Attached: YES NO Contract Attached: YES 9 � ❑ 1. Minimum Circuit Ampacity (Wire Size): �,, L 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 3. Voltage of Circuit (208/240/480): �t 4. Size Disconnecting Mean; Contractor's Company Name: State Certificate or Registration N. L^,A@ 0°1 l -S 0Q Certificate of Competency Signature (Quallfler's signature only) Phone: 300 03 2 S�� Date: .13 %/4 UNIT BEING REPLACED DATA NEW UNIT 12� MANUFACTURER f' 49 AHU or PKG. UNIT MODEL # COND. UNIT MODEL # a KW HEAT NOM TONS AHU 8 CU 143 PKG 1 M.C.A AHU CU q.5 PKG AHU 60 CU Lt PKG 2 M.O.P AHU66 CUB PKG AHU CU PKG 3 VOLTS AHU CU PKG PKG UNIT / / PKG UNIT EER/SEER to YES NO REPLACING DUCTS YES NO REPLACING THERMOSTAT &ES NO YES NO NEW 4 °CONCRETE SLAB YES YES NO NEW ROOF STAND YES YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): �,, L 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 3. Voltage of Circuit (208/240/480): �t 4. Size Disconnecting Mean; Contractor's Company Name: State Certificate or Registration N. L^,A@ 0°1 l -S 0Q Certificate of Competency Signature (Quallfler's signature only) Phone: 300 03 2 S�� Date: .13 %/4 AHRI Certified Reference Number: 5886249 Date: 1/30/2014 Product: Split System: Air - Cooled Condensing Unit, Coll with Blower Outdoor Unit. Model Number: 4TTS6049A1 Indoor Unit Model Number: *AM7AOC48H41 Manufacturer: TRANE Trade /Brand name: XB16 Series name: Manufacturer responsible for the rating of this system combination is TRANE Rated as follows In accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, Independent, third party testing: Cooling Capacity (Btuh): 46500 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16.00 IEER Rating (Cooling): * Ratings followed by an asterisk (h indicate a voluntary rerste of previously published date, unless accompanied with a WAS, which indicates an involuntary rerste. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the products) fisted on this Certificate. AHRI expressly disclaims all gabiiity for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data fisted on this Certiffmde. Certified ratings are valid only for models and configurations fisted in the directory at www aheidirectory o% TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shag only be used for individual, personal and confidential reference purposes. The conterds of this Certificate may not, in whole or In part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory org, AUED Air- Condffioning, Heating, click on "Verify, Certificate" fink and enter the AHRI Certified Reference Number and the date on AFW and Reifigeration institute which the certificate was Issued, which is gated stove, and the Certificate No„ which is gated below. ©2013 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130355888334371046 Load Short Form Jab: 1045 Date: January 30 2014 Entire House By: Edd Helms Air Conditioning 17850 NE MhAvenue, Miarrd, Fl 33162 Phone: 305 -853 -2530 License: CACO21309 FBI Q, Iigwz a • • • For Alex Qunitana 1045 NE 97th Street, Miami Shores, Fl. 33138 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat COOLING EQUIPMENT 111 AIRRIFIN r- • • • 13950 Trade XB16 46500 Btuh Cond 4TTB6049E1 Htg Clg Infiltration Outside db ( °F) 51 90 Method Simplified Inside db ( °F) 70 75 Construction quality Average Design TD ( °F) 20 15 Fireplaces 0 Daily range - L Inside humidity ( %) 30 50 Moisture difference (gr /lb) -11 57 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat COOLING EQUIPMENT 16 SEER Area Make Trane Btuh 13950 Trade XB16 46500 Btuh Cond 4TTB6049E1 cfm 0.046 Coil *AM7AOC48H41 0 in H2O AHRI ref 5886249 100 EFF 1583 Efficiency 13.0 EER, 12.2 kW Sensible cooling 41657 Btuh Latent cooling 24 OF Total cooling 1583 cfm Actual air flow 0.050 cfm/Btuh Air flow factor 0 in H2O Static pressure Latent cooling Load sensible heat ratio 16 SEER Area 32550 Btuh 13950 Btuh 46500 Btuh 1583 cfm 0.046 cfm/Btuh 0 in H2O 0.88 34373 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Room1 2056 31566 34373 1583 1583 Entire House d 2056 31566 34373 1583 1583 Other equip loads 0 0 Equip. @ 0.95 RSM 32792 Latent cooling 4693 Tr)TA I C 711GG 7 CGG 13"7A C= A 609 A G09 J I JUU J I -ruJ I IJUJ I JUJ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2014 - Jan- 3018U5:06 1 wrightsoft° wg"ufte@ Universal 2012 12.1.06 RSU07042 Page 1 .jack .. hftoft WACVMexQuiniara16 Seer TTB4ton .rup Calc =MJ8 Front Door faces: S Project Summary Entire House Edd Helms Air Conditioning Job: 1045 Date: January 30 2014 By: 17850 NE 5thAvenue, Kong. 305-653-2530 e: CACO21309 �_�.. . For Alex Qunitana 1045 NE 97th Street, Miami Shores, Fl. 33138 Notes: Q U a. M... Weather. Miami, FL, US Winter Design Conditions Summer Design Conditions Outside db 51 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 20 OF Design TD 15 OF Daily range L Relative F�umidity 50 % Moisture difference 57 gr /lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25073 Btuh Structure 22903 Btuh Ducts 6492 Btuh Ducts 11470 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31566 Btuh Use manufacturer's data n Rate/swing multiplier Equipment 0.95 Infiltration sensible load 32792 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1694 Btuh Ducts 2999 Btuh Area Heating Cooling Central vent (0 cfm) 0 Btuh (fta) 2056 2056 Equipment latent load 4693 Btuh Volume (fta) 16448 16448 Air changes /hour 0.32 0.16 Equipment total load 37485 Btuh Equiv. AVF (cfm) 88 44 Req. total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade XB16 Model Cond 4TTB6049E1 AHRI ref Coil *AM7AOC48H41 AHRI ref 5886249 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.2 kW Sensible cooling 32550 Btuh Heating output 41657 Btuh Latent cooling 13950 Btuh Temperature rise 24 OF Total cooling 46500 Btuh Actual air flow 1583 cfm Actual air flow 1583 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrilghtsoft° Right sulte® Universal 201212.1.08 RSU07042 2014-Jan-30 1Page I Page 1 AM _ hLmftWACWexQu inlara16 Seer TrB4tonrup CaIc =MJ8 FrontDoortaoes:S Right -M Worksheet Job: 1045 Entire House Date: January 30 2014 Edd Helms Air Conclitioning By: 17850 NE 5thAvenue, Miami, Fl 33162 Phone: 305 -853 -2530 License: CACO21309 1 Room name Entire House Rooml a Exposed wall 2024 It 2024 ft 3 Room Might 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 2056.0 ft 5 Room area 2056.0 ft2 2056.0 ft2 Ty U -value Or HTM Area number (Btuh/ft2- °F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP /S Heat Cool Gross N/P /S Heat Cool 6 w 13AA Ooc 0.584 n 11.39 12.73 312 312 3553 3972 312 312 3553 3972 w 13AA -Ooc 0.584 a 11.39 1273 488 488 5557 6213 488 488 5557 6213 V)I LG 13AA -0cc 0.584 s 11.39 1273 328 319 3833 4061 328 319 3633 4081 1A -clom 1.270 s 24.76 38.39 9 0 223 345 9 0 223 345 w 11 13AA -0oc 0.584 w 11.39 1273 456 456 5193 5805 456 456 5193 5805 w 13AA -Ooc 0.584 nw 11.39 12.73 36 36 407 455 36 36 407 455 C 16D -58td 0.018 - 0.35 0.62 2056 2056 722 1273 2056 2058 722 1273 F 22A -tpl 0.989 - 19.29 0.00 2056 202 3904 0 2056 202 3904 0 6 c)AED excursion 35 35 Envelope loss/gain 23192 22160 23192 22160 12 a) Nitration 1881 743 1881 743 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 25073 22903 25073 22903 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 25073 22903 25073 22803 15 Duct loads 26% 50% 6492 11470 260/6 50% 6492 11470 Total room load 31566 34373 31586 34373 Air required (cfm) 1583 1583 1583 1583 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. �J . wrightsofC 2014 - Jan - 3016,05,08 1" RlghtSuit� Univen�i 201212.1.06 RSU07042 Page 1 . htsoftWACWexQuinlara16 Seer TTB4ton .rup Calc =MJ8 Front Door faces: S