CC-14-56Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 inspection Number: INSP- 208704 Permit Number: CC -1 -14-56 Inspection Date: March 13, 2014 Permit Type: Commercial Construction Inspector: Rodriguez, Jorge Owner: EVERETT, HENRY AND FRANCES Job Address: 9600 NE 2 Avenue Miami Shores, FL 33138- Project: <NONE> Inspection Type: Final Work Classification: Alteration Phone Number (727)461 -4370 Parcel Number 1132060132510 Contractor: PROFESSIONAL BUILDING Phone: (305)442 -8884 Buildina Department Comments REPAIR 2 REAR STRUCTURES ONE WOOD ONE Infractlo Passed Comments INSPECTOR COMMENTS True CONCRETE. Inspector Comments Passed lzdt4 CREATED AS REINSPECTION FOR INSP- 208666. No permit on site Failed El Correction Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. For Inspections please call: (305)762 -4949 March 13, 2014 Page 7 of 1 BUILDING Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax 305) 756.8972 NSP.ECTJAI 1�0 _ _ . A R: (305) 762.4949 PERMIT APPLI Permit Type: BUILDING C JOB ADDRESS: JAN o � ao�3 FBC 20 LC;) r - Permit No. C C 1 --A - S f° Master Permit No. nc 1113 2,6 ( ROOFING V97 194F ()- Rt34 A)G Zkug City: Miami Shores County: Miami Dade Zip: Folio/Parcel #: U — 37,Q& - p J ' Z60 C) U the Building Historically Designated: Yes NO ✓ Flood Zone: OWNER: Name (Fee Simple Titleholder): Er 15• euey;p'_6i Phone#: Address: ties D01)n A1. City: State: 3367(v Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company Name:jDTP�i! Address: 2 33 Z City: G' A10 6-3 State: Zip: Qualifier Name: �'L t i , Phone #: 3bsq$�a Da State Certification or Registration #: Contact Phone #: DESIGNER: Architect/Engineer: Address: -.- -= 382 ((Os Value of Work for this Permit: $ 151�0Do Square/Linear Footage of Work: a OF Type of Work: ❑Addition DAlteration ❑New VRepair/Replace _ ODemolition Description of Work: Color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $_ Technology Fee $ TOTAL FEE NOW DUE $ v Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate rmit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TAand Al ONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR E14PROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature / /v'��/l/1�(�✓h "�/_ - - - " Signature Owner or Agent actor The foregoing instrument was acknowledged before me fthhiis day of , 20L3 by FJrJ M 9& ESE ✓W , who is personally known to me or who has produced As identification and who did take an oath. NOTARY The foregoing instrument was acknowledged before me this day of R9f , 20 a, by 6411er *s , who is pers ally kno to me or who has produced as identification and who did take an oath. NOTARY Sign: er 111111A Sign: _ Print: r Print: _ My Commission Exp' s � `'�;;, SILVIA M DUA AN My Corr .: MY GOt 1MISSION # EE063152 EXPIF.If S February 09, 2015 (40�) 388 -0 153 F aN tVIC8.00T11 �k�k�kskakH =HisIa�kakA�akakskskikakak Hi H iNaH�Ha�akakakaksksIaH=sksIaXa� APPROVED BY _ \,:7-A I v`/ ` 7 Plans Examiner D 114 Structural Review (Revised 3 /12/2012)(Revised (Y7 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) I Juk O,1IA 1A DURAN W COMMISSION # EE063152 EXPIRES February 09, 2015 Zoning Clerk 4, • NOTE: ALL SHEET MUST BE REVIEWED MIAMI -DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street (Coral Way) • Miami, Florida 33175 -2474 • (786) 315 -2000 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI -DADE FIRE RESCUE AND /OR ENVIRONMENTAL SERVICES W v V PROVIDE MUNICIPAL PROCESS NUMBER HERE J2 Job Address q 6q ® 0 0 0 a °g U Ge Contractor No. 0 W Folio = Z 00 Last four (4) digits of Qualifif @1r No. 02 F � V~ � 9= _1c/11 f Contractor Name L° n7t� Lot Block ;CO Qualifier Name -'1SF B ,4 1,44 n6, S a&- Subdivision PBpg 02 z Address Z-530- 076110n-0 51- City C 6-Abl -S-5 State _Zip A 3 Metes and bounds [ ] New Construction on ] Demolish Current use of property 00' 1" "15rc(41 v� Vacant Land [ ] Shell Only [ ] Alteration Interior [ ] Addition Attached Description of Work 5-(-Y-a W W [ l Alteration Exterior [ ] Addition Detached o [ ] Relocation of Structure [ ] Re -Roof "p,617Ci-S a ? [ ]Enclosure ]Repair [ ] Foundation Only [ ]Tent Sq. Ft. Units Floors [ ] Repair Due to Fire Value of Work Wle & 00, °l'"" [ MBLD* ` N [ ] Chg. Contractor W Owner a/LWPT__�_ W Category [ ] Re -Issue Address °L L,!10 ® N Cy [ ] MELE [ ] Re -Stamp City"(.S�S State Zip I_ ¢ [ ] MLPG [ ] Revision ca W Phone Last four (4) digits of oW [ ] MMEC [ ] Not Applicable for [ ] FIRE ¢ Fire 0 Owner's Social Security No. Name st"(,q _&L%1° Owner 0 za W Address Address City State Oa 2 D City - 61010 10 ` State E l Zip 33 L3 t=z v z ILO Phone OS 1%� 3D S- O3 q ?7.-4 � W _Zip Phone I am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible at the rate of $190 for the first hour Nand $65 per each additional hour in addition to the review fees. Minimum charge one -hour. EW � 114 Request: Date: 1 W 9 2nd Request: Date: 3'd Request: Date: I am requesting Optional Plan Review (OPR) to be scheduled as soon as possible at the rate of $75 for each discipline. ° a Additional review fees may apply. 10- 01 i= 161 Request: Date: o 2nd Request: Date: 3'd Request: Date: 123_01- 192 8/13 BUILDING PERMIT CATEGORIES CATEGORY DESCRIPTION PERMIT TYPE BUILDING 01 GENERAL BUILDING — COMMERCIAL MBLD 02 SUB — GENERAL BUILDING — RESIDENTIAL MBLD 08 CANVAS AWNING MBLD 10 COMMUNICATION TOWER MBLD 15 DEMOLITION MBLD 29 METAL AWNING & STORM SHUTTER MBLD 48 SCREEN ENCLOSURES MBLD 55 SWIMMING POOL MBLD 56 TENNIS COURTS (SURFACE PAVING) MBLD 86 TRAILER TIE DOWN MBLD 88 WALK -IN COOLER MBLD 91 MARINAS MBLD 92 LOW SLOPE APPLICATIONS (GRAVEL, SMOOTH MODIFIED, SINGLE PLY) MBLD 95 SHINGLES (ASPHALT, FIBERGLASS) MBLD 96 SHINGLES (METAL ROOFS/WOOD SHINGLES & SHAKE) MBLD 97 STAGE 2 VAPOR RECOVERY SYSTEM MBLD 99 SOIL IMPROVEMENT MBLD 0100 BULK STORAGE PROPANE TANK MBLD 0101 REMOVABLE STORM PANELS MBLD 0107 TILE ROOF MBLD 0110 WATER MAIN MBLD 0111 SITE PLAN MBLD 0112 INDOOR EVENT /EXHIBIT MBLD ELECTRICAL 04 FIRE ALARM SPECIALTY MELE 16 SPECIALTY WIRING MELE 38 GENERATORS MELE LPGX 01 LIQUEFIED PETROLEUM GAS MLPG 02 MISCELLANEOUS MLPG 04 LIQUEFIED PETROL. GAS /STATE MLPG MECHANICAL 09 ABOVE/BELOW GROUND TANKS/PUMPS & POLLUTANT STORAGE SYSTEM MMEC 38 COMMERCIAL HOODS MMEC 43 FIRE CHEMICAL MMEC 46 SPRAY BOOTHS MMEC 48 SMOKE CONTROL MMEC 52 RESIDENTIAL ELEVATOR MMEC FIRE 32 FIRE SPRINKLER FIRE of st JOB: STRUCTURAL CALCULATIONS FOR REAR DOOR ENCLOSURE ADDITION SITE ADDRESS: 9608 AND 9612 NE 2 AVE. MIAMI SHORES FL 33138 THIS IS AN EXISTING UNPERMITTED STRUCTURE. CLIENT. FRANCIS EvERETT, OWNER. SCOPE OF WORK IS RELATED TO STRUCTURAL REINFORCEMENT. _., PAVED PARKING LOT — EXISTING —I EXISTING N.I.C. ADD 1 2x4 PT DD 1 2x4 PT ADD 1 2x4 PT STUD IN THIS ELECT. RM. C.B.S. CORNER. —1 4" —1 " 0.0 01 1 N I I r_-0.0" —3.5" 1*01 -3.5" ;1 3' -8 r —5.5" —11" NINIINI� illYl ADDITION FLOOR PLAN SCALE: 3/8" = 1' -0" XISTING MET. SHEET FLANGE TO REMAIN. 2x4 P.T. LEDGER REINFORCE WITH REPLACE DAMAGED ROOF PLYWOOD NEAR (4) 3/8x4.5" EXTRA THE OUTER EDGES OF THE STRUCTURE: EXPANSION BOLTS r 19/32" PWD/ BD. #8D RINKSHANK NAILS AT 6" O 24" APART O.C. .C. 20 GA. SIMPSON TIE I "HETA20 —TSS" W/9 16D ADD 1 2X4 PT. SECTIONS GALV NAILS TO TRUSSES. 1/2" GYP. BD. BELOW THE TOP BEAM, MAX. UPLIFT 1890 LBS. TIGHT BETWEEN STUDS. 2x4 P.T. 19/32" P.T. BD. FASTENED STUDS 0 16" U WITH 1/8x2" SCREWS @ 10" 2nd STEP. --� 3rd STEP. 1st STEP INSIDE BLDG. ' . -- FLOOR LVL. ADDITION SECTION SCALE: 3/8" = 1' -0" 7,_23.. (2)2x4 P.T. FRAME BOTTOM. REINFORCED WITH (6) 3/8x5.5" EXPANSION BOLTS 24" APART O.C. PARKING LOT LEVEL EXISTING PAVEMENT COMPACTED SOIL, EXISTING CONCRETE SLABS AND FOOTINGS. C.AUDIO A. JOFRE P.E. FL REG.# 28531 334 NE 102ND. STREET. MAIMI SHORES - FL 33138 786 - 382 -1695 P.E. SIGN AND SEAL DATE: 17, P.E. SIGN AND SEAL COVERS THE ENTIRE SET OF COMPUTATIONS SHEETS FROM SHEET 1 TO 5. Sheet S -11 4 � JOB: STRUCTURAL CALCULATIONS FOR REAR DOOR ENCLOSURE ADDITION SITE ADDRESS: 9608 AND 9612 NE 2 AVE. MIAMI SHORES FL 33138 CLIENT FRANCIS EVERETT, OWNER. Fol 2 STORY EXISTING BLDG. ADDITION WEST ELEVATION SCALE: 3/8" = 1' -0" KOURI IMM lll� Rd'01IRM 1. REMOVE THE INTERIOR DRYWALL OF THE ENCLOSURE TO EXPOSE THE FRAME. 2. REINFORCE THE FRAME AS INDICATED ON PLAN AND SECTION. REPLACE DRYWALL. 3. AFTER REPAIRING THE ROOF PLYWOOD, RE —ROOF WITH SAME TYPE MATERIAL AS THE EXISTING ROOF SURFACE. 4. PROVIDE NEW 6" x 4" GALV. MET. SHT. TO THE ROOF EDGE. 5. PROVIDE NEW 6" W. GALV. MET. SHT. TO THE WALL BOOTOM EDGE. AROUND THE EXTERIOR OF THE ENCLOSURE. 6. COVER THE EXTERIOR SHELL WITH 30# CONSTRUCTION PAPER. 7. PROVIDE GALV. STUCCO WIRE LATH TO THE EXTERIOR WALLS. 8. APPLY 1/2- STUCCO LAYYER FINISH TO SMOOTH. PAINT TO MATCH THE BUILDING. Sheet S -21 R JOB: STRUCTURAL CALCULATIONS FOR REAR DOOR ENCLOSURE ADDITION SITE ADDRESS: 9608 AND 9612 NE 2 AVE. MIAMI SHORES FL 33138 CLIENT: FRANCIS EVERETT, OWNER. PARTIALLY ENCLOSED ADDITION: BEAM CALCULATIONS DECK LOADING CONDITIONS LIVE LOAD LL 30 PSF DEAD LOAD DL 10 PSF TOTAL LOAD (PSF) 40 PSF DURATION FACTOR 33% WIND LOADS Exposure Category °C° Mean Roof Ht = 9.5' Building Category 1 Importance Factor= 1.0 Wind Velocity 175 mph ASCE 7 -05 FBC 2010 UNIFORMLY LOADED BEAM IN BENDING RECTANGULAR WOOD BEAM SUPPORTED ON BOTH ENDS, LOADED EVENLY, WHEN: 1. Load on beam = 304 lbs. 2. Span of beam = L= 3' -4° 3. Roof deck width= 4' 4. Roof Overhang = 7° 5. Combine LL+ DL = 30 PSF • i c.: 4'- EXISTING BUILDING A) BEARING LOAD ON THE BEAM = 3.3 X 2.3 = 7.6 S.F. W = 7.6 X 40 PSF = 303.6 lbs. C) FIND SECTION MODULUS REQUIREMENT. Divide maximum bending moment in Inch— pounds by allowable fiberstress for the wood grade. Section Required = Mmax x 12 / Fb Sreq = (455.4 x 12) / 1150 lbs/ Sq in. Sreq = 4.75 inches 3 Sreq = 5 in 3 W bUPIJUKIED O.C. AT OPENINGS PORTION OF ROOF BEARING ON THE BEAM. B) MAXIMUM BENDING MOMENT FORMULA Mmax =WL /8 Mmax = (303.6 x 12) / 8 Mmax = 3,643 / 8 Mmax = 455.4 Ft /Lbs 3 D) SELECT A BEAM WITH A SECTION MODULUS OF 5 IN + Formula for determining section modules for a rectangular beam : S = b (dxd) / 6 TRY (2) 2x4 ; actual dims 1.5 °x3.5° S = 1.5 (3.50.5) / 6 S = 1.5 x 12.25 / 6 3 3 S = 18.4 /6 = 3.066 In 2 = 6.13in 6.13 cu.in. > 5 cu.in = PASS Sheet S -3 JOB: STRUCTURAL CALCULATIONS FOR REAR DOOR ENCLOSURE ADDITION SITE ADDRESS. 9608 AND 9612 NE 2 AVE. MIAMI SHORES FL 33138 CLIENT FRANCIS EVERETT, OWNER. CONNECTION OF LEDGER TO EXISTING TIE BEAM CALCULATION a) Load on Ledger = 1,155 lbs. b) # of connections = 5 expansion bolts 0 2' -0" O.C. c). Sh. F 0 ea. end = 1,155 Ibs / 2 = 577.5 LBS d). Type of bolt = 3/8" x 5" Wedge —all Mech. Hot Galv. 1 Weight on beam — 1,155# 2 Total horizontal wind force at bending point = 4,199.2# 3 Maximum shear stress applied Vmax= (v +h) = 292.4# 4 Maximum tensile stress applied Tmax= (15 +V) /10 =262.5# 5 Allowable Shear Stress on "H" 3/8 "x5" exp bolt= 1055# 6 Allowable tensile stress for some screw = 1140# 7 Check unity condition (Tmax /Tall + Vmax /Vail) = 0.51 < 1.0 Use (5) 3/8 "Ox5" exp bolts galvanized at each connection. a) Load on bottom beam = 98SF X 15# = 1,470 Ibs. b) # of connections = 7 expansion bolts 0 2' -0" O.C. c). Sh. F 0 ea. end = 1,470 Ibs / 2 = 735.0 LBS d). Type of bolt = 3/8" x 5" Wedge —all Mech. Hot Galv. 1 Weight on bottom beam = 2 Total horizontal wind force at bending point = 3 Maximum shear stress applied Vmax= (v +h) _ 4 Maximum tensile stress applied Tmax= (13 +V) /11 5 Allowable Shear Stress on "H" 3/8 "x5" exp bolt= 6 Allowable tensile stress for same screw - 7 Check unity condition, (Tmax /Tall + Vmax /Vall) _ Use (7) 3/8 "Ox5" exp. bolts galvanized at 2' -0" 1470# 440.3# 137# = 150.6# 1055# : embed = 3.0" 1140# 0.5 < 1.0 O.C. Sheet S -4 JOB: STRUCTURAL CALCULATIONS FOR REAR DOOR ENCLOSURE ADDITION SITE ADDRESS: 9608 AND 9612 NE 2 AVE. MIAMI SHORES FL 33138 CLIENT FRANCIS EVERETT, OWNER. DESIGN WIND LOAD CALCULATIONS. Method 1. Simplified Procedure. Horizontal pressure zone "C ". ps = combination of windward and leeward net pressures. Formula: ps = Wzt I pS30 X = adjustment factor for building height and exposure, from ASCE Fig. 6 -2 Kzt = topographic factor as defined in Section 6.5.7 evaluated at mean roof height, h. I = importance factor as defined in Section 6.2 pS30 = simplified design wind pressure for Exposure C, at h = 10 ft, and for I = 1.0 Kzt = (1+ K1, K2, K3) 2 Kzt = (1+ 0) 2 2. HORIZONTAL PRESSURE ZONE "C" CALCULATION ps = 1.21x 1 x 1 x 34.4 ps = 41.6# h (8.9 FT.) x w 0 3.0 FT.) = 115.7 S.F. Kzt = 1 115.7x41.6 = 4,813# 7 exp. bolts x 1,140# = 7,980 lbs. (7,980 / 4,813) x 100 = 165.890 O.T.M. safety factor PASS 36 "x80" = 2,880/144 = 20 S.F. 832 / 2 studs = 416 ft. lbs. ELM Wil 20 SF x 41.6# = 832 LBS. a) FIND SECTION MODULUS REQUIREMENT. Divide maximum bending moment in inch — pounds by allowable fiberstress for the wood grade. Section Required = Mmax x 12 / Fb Sreq = (416.0 x 12) / 1150 lbs/ Sq in. Sreq = 4.34 inches 3 Sreq = 5 in3 b) Section modulus of studs in the design is (2) 2x4's = 6.13 in3. c) Section modulus allowable is 140.9% STRONGER than S Req. PASS Sheet S-5-