Loading...
BPP-13-1626Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 inspection Number: INSP- 208351 Permit Number: BPP -7 -13 -1626 Inspection Date: March 11, 2014 Permit Type: PoolslWhirlpools/Hot Tubs Inspector: Rodriguez, Jorge Inspection Type: Final Owner: GOMEZ, LIMA Work Classification: New Job Address: 10109 N MIAMI Avenue Miami Shores, FL 33150- Project: <NONE> Contractor: GENIE POOLS Building Department Comments Phone Number Parcel Number 1132060131510 Phone: 305 - 260 -9555- NEW SWIMMING POOL Infractio Passed Comments INSPECTOR COMMENTS True Inspector Comments Passed CREATED AS REINSPECTION FOR INSP - 195548. Missing one alarm Failed Correction Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. For Inspections please call: (305)762 -4949 March 11, 2014 Page 1 of 1 GENIE -3 OP ID: GJ A`c, °R °r CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 07/17/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. C_ IMPORTANT: If the certificate holder is an A[I9171ONAL INSURED, the policy(les) must be endorsed. If SUBRAGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Phone: 321-397-381- Insurance By Ken Brown, Inc. PO Box 948117 Fax: 321 - 397 -3888 Maitland, FL 32794 -8117 David R. GrIf the CONTACT NAME PHCNo AI No : E-MAIL ADDRESS: INSURER(S) AFFORDING COVERAGE NAIC $ INSURER A: Markel Insurance Company 22616 INSURED Genie Pools Genie Pools Florida, Inc. Suite 201 12940 S.W. 128th St. Miami, FL 33186 INSURER B:Amerisure Ins Company 19488 INSURER C: Progressive Express 10193 INSURER D: DAMAGE PREMISES Ea «xurrance INSURER E MED EXP (Any one person) INSURER F PERSONAL &ADVINJURY COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE 1kDDL SUOR POLICY NUMBER POLICY EFF D /YYYY) POLICY EXP (MM1DDNYYYl LIMITS B GENERAL LIABILITY X coMMERciAL GENERAL umiuTY CLAIMS -MADE Fx_1 OCCUR �jo,,..: d . �� GL20637910302 07/20/2013 07/20/2014 EACH OCCURRENCE $ 500,000 DAMAGE PREMISES Ea «xurrance $ 100,000 MED EXP (Any one person) $ 5,000 PERSONAL &ADVINJURY $ 500,000 GENERAL AGGREGATE $ 1,000,000 GEHLAGGREGATEU MIT APPLIESPER: 7 X POLICY PRO- JECT LOC PRODUCTS - COMP /OPAGG $ 1,000,000 $ C AUTOMOBILE LIABILITY ANY AUTO ALL OWNED X SCHEDULED AUTOS AUTOS AUTOED HIREDAUTOS S 019609370 11/29/2012 11/29/2013 CEa acddent OMBINED SINGLE OMIT 300,000 BODILY INJURY (Per person) $ BODILY INJURY (Per acddent) $ d ��R DAMAGE $ $ UMBRELLA LIAB EXCESS LIAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED I I RETENTION $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETORIPARTNERIEXECUTIVE YIN OFFICERIMEMBER EXCLUDED? El (Mandatory In NM If yes, describe under DESCRIPTION OF OPERATIONS below NIA MWC003049502 05/28/2013 05/28/2014 X WC STATU- OTH- T RY u TS E.L. EACH ACCIDENT $ 100,000 E.L. DISEASE - EA EMPLOYEE $ 100,000 E.L. DISEASE- POLICY LIMIT $ 500,00 DESCRIPTION OF OPERATIONS I LOCATIONS /VEHICLES (Attach ACORD 101, Additional Remarks Schedule, H more space Is required) fax: 305 - 756 -8972 CERTIFICATE HOLDER CANCELLATION MIAMISH SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Miami Shores Village g THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 10050 N.E. 2nd Avenue AUTHORIZED REPRESENTATIVE Miami Shores, FL 33138 �jo,,..: d . �� ACORD 25 (2010105) ©1988 -2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 0812012013 23:20 q� d. B 3052609777 GENIE POOLS CERTIF1P_A`PC nr v v 1 rrr■ PAGE 01101 INDI IS TO CERTIFY THAT THE PCLICIEg OF INSURANCE LISTED BELOW WAyE BEEN ISSUED Tp THE INSURED NAMED ABOI INDICg7Ep, NOTVViTH9T►1NDiNG ANY REQUIREMENT, TERM OR CONDITION OF ANY R�YISiOH N MBER: CERTIFICATE MAY 8E ISSUEp OR MAy pERTgIN, THE INSURANCE AFFORDED 6Y THE POLICIES DESCRIB6D HEREIN IS SUBJECT TO ALIHE TERMg CONTRACT 1?R OTHER DOCUMENT WITH RESPECT TO WI•IICH THIS CXCLU510NS AND CONpITIONS OF &UCy POLICIF_.^, LIMITS SHpN/N MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE GENPAAL Ii POL I NUMBER u X COMLt�CrgL G6�rERAI LIASILIiy OL CUR I LIMITS GL20637910302 107/20/2013 07120/2014 cHOCCtraReNCE $ 500,01 CUSI1LtS -MACE � I I PREIUI.C4'c I JeFPAMD � CMGREOAT S tjw POU -AMMODILE Maury AVTO � X AUTOS UMBfieLLA LIAg XCESS LIAR r ANO A ANY DESCRIPrON OrOPERA=NS! "Ex: 305- 756 -9972 Fw ­­e 1 •�OMPIOPAGG $ � SCHEDULED I ............. 11129/2012111/2912013 BODILYIW(, (pmpefeen) S N0rumED AUTOS I 9ODlLY 1NJURy (poridr:al) $ ^I OCCUR I I ac R ni E S i S Y1:1 INIA I I'vwc 030s9502 1 09/2812015 0512812014 ! VEHICLES (Attach ACORD 101, ArtgR10aa1 gemarka Sclmtlare, N mare space 1E squired) Mlami Shores Village Building Department 10050 N.E. 2nd Avenue Miami Shares, K 33138 L�) 115 -arizi, ACOt2D 26 (2010105) S 1 MIAMISH SHOULD ANY OF THE A DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE E tNEREOF, ii WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUT110RIZEO REPRESSAITATNE aA The ACORD name ano logo are registered marks ofA�ORD CORPORATIOP►, AI>I 1i reserved. NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT N0. TAX FOLIO NO. t' - 3 2-04P ` 013 -15) 0 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. p it C-t' ed b ' t,,,, i Z � (A a 1jgC4 C> c, 'Y-r t ` St.. - 2_0 I FL 331 0 1. Legal description of property and streettaddress: M 1 Q r" 1 ie h" t o f✓ l q Ins i It n h r)n t o-_7 f7 in 1 ()a t't 2. Description of improvement: f # f�f iff # #f f ff ff f fif # ffifi fff f # C I✓'N 201 3RO59291L 6 OR Sk 28745 Ps 4790i (fps) RECORDED 07/29/2013 11:550:36 HARVEY RUVIHv CLERK OF COURT €1IAnI -DARE COUNTYr FLORIDA LAST PAGE Space above reserved for use of recording office l0-- l3 I 3.Owner(s) name and address: UnCA CX ZP t() t (2 Q ij e r M t GLYYI t �S V \Cis- ef) P L Interest in property: OLL)iAAX' 22 Name and address of fee simple titleholder. 4. Contractor's name, address and phone number. % %a ty c ;, r L Inc, CS ®S 2 G 0 r CI SS G 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number Amount of bond $ 6. Lender's name and address: I,1 7. Persons within the State of Florida designated by Owne; j"6 i Section 713.13(1)(a)7., Florida Statutes, 4REOV CgRT ►FY Name, address and phone number. , nfe6 ."V 8. In addition to himself, Owners designates the following 713.130)(b), Florida Statutes. Name, address and phone number 9. Expiration date of this Notice of Commencement: on Ao 20�� by as Pr vied in Section (the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT Signature(s) of Om&! or O OffiffiOfficer/Director/Partner/Manager Prepare! By ° Prepared By Print Name Print Name Title/Office Title/Office STATE OF FLORIDA COUNTY OF MIAMI -DADE The foregoing instrument was acknowledged before me this 2-� day of (ULj 201 Byn� ®t�2 V d Individually, or LJ as for Personally known, or ❑ produced the following type of identification: Signature of Notary Public: Print Name: (SEAL) MERIFICATION PURSUANT To SECTION 82,525, FLORIDA STATUTES OE Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true, to the best of my knowledge and belief. Signatur f r 0 ''s Authorized Officer/Director/Partner/Manager who signed above. By By 123_ 3 9/12 Notary Public - State of Florida My Comm. Expires Dee 28, 2014 Commission # EE 51872 Bonded Through National Notary Assn. e� 0 Miami Shores Village Building Department . 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 , INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JUL 9 203 By" . rJ ctioo_oLnena3 o. i Fri err FBC 20 Permit No. Master Permit No. -111)2 ROOFING Uz JOB ADDRESS: 10 1 OGI N M 10-M 1 AJ etA WQ City: Miami Shores County: Miami Dade Zip: 15 U Folio/Parcelk i i - 3 20 Cp - Of 3- 15 10 Is the Building Historically Designated: Yes NO ✓ Flood Zone: •�� OWNER: Name (Fee Simple Titleholder): L..14201 04 QKYU Z Phonek ( 75(o) 'ZZ 1 -5340 Address: 10109 N t`'l1(,1Jmt Algen%,Q City: Ott OyrM i ' SYtO/( ED State: F L _zip: 33150 Tenant/Lessee Name: N } A _Phonek NON Email: N l A CONTRACTOR: Company Name: u tw i c p001 S Phonek 05)2 (a 0 -9555 Address: 2 g Ll 0 E1-4 l2 (& City: M 1 CIv� State: IL Zip: Qualifier Name: L. t Z 1 (2t_kt d_A GL Phonek. State Certification or Registration #: !;V G I q 510 5 5 Certificate of Competency #: Contact Phonek (3 06) 7XQ0 -q 54 5 Email Address: L Li U OA-6-� a 6D Q Ul t`Q- Ok DESIGNER: Architect/Engineer: ec u%.6w bcl_k ("2 o Phone #: Value of Work for this Permit: $ A P, 000 Square/Linear Footage of Work: L4 S F Type of Work: ❑Addition ❑Alteration 3New ❑Repair/Replace ❑Demolition Description of Work: new SW %ry\C, `k_2 pool Submittal Fee $ Permit Fee $ Scanning Fee $ CCF $ I CO /CC $ Radon Fee $ DBPR $ Bond $ No Training/Education Fee $ Technology Fee $ �e Fee $ Structural Review $ TOTAL FEE NOW DUE $ • 4 Bonding Comp ay's Name (if applicable) Bonding Coj;'s Address 00 City State Mortgage Lender's Name (if applicable) 01)", r Mortgage Lender's Address City State zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not b pproved and a reinspection fee will be charged. Signature Signature Q1 (✓l Owner or Age Contractor The foregoing instrument was acknowledged before me this d The foregoing instrument was acknowledged before me this day of L , 20 d by L1114 61ow2 day of UL .20 ►-, by x-12 M. el UDR D1,41 who i r�yknown me or who has produced who is pe"ally known th a or who has produced As identfication and who did take an NOTARY Sign: Print: (J My Commission APPROVED BY EXPIRES: July 4.2D17 BMUW TMi W" UNWahm WEA ,� J3 Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) NOT Sign: Print: My Commission identification and who did take an oath. Zoning Clerk r F; JUL 1 9 �J 1 1 j�l��= o oomme� Miami sho" es illage , Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 SWIMMING POOL OWNER'S CERTIFICATION Date -11 6b/'13 Miami Shores Village Building & Zoning Department Attention: Building Official I certify that I am the legal owner of the property described as l o t (3, 1 Yx "try. 5f:k-, LO k, 114 b I V- I I ("tClMk s -e (- cry, No Pb e2 i C - -70, located at w c i cc; N M� curn % A-�e, In accordance with Section 33 -12 ft Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. I further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the pool. , .r Legal Owner 6' Note: This certification is to be submitted with a swimming pool permit application in duplicate. iami Shores village �• JUL 1 9 250 -..---Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 NOTICE OF REQUIREMENTS RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at l01 riq N 1\4 iijLty� A A-j W Miami Shores, FL, and hereby affirm that one of the following methods will be used to meet the requirements of Chapter 515, Florida Statues and the Florida Building Code R4101.17. Please Initial the methods) to be used: The pool will be equipped with an approved safety pool cover that comp lies with ASTM F1346 -91. (Submit Manufacturer's Specifications). A continuous, one -piece (child) barrier meeting the requirements of Florida Building Code R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location and method of attachment, including one end that shall not be removable without the aid of tools. (Submit Manufacturer's Specifications). r A combination of non - dwelling walls and fences (screen enclosure, child fence, masonry fence walls, chain link or wood fence, etc.) will protect t he pool perimeter. The plans must specify t he type and location of all non dwelling walls. Florida Building Code, R4101.17.1 Z- ( Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all windows and doors will be equipped with exit alarms complying with Florida Building Code, R4101.17.1.9 (Submit Manufacturer's Specifications). Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all doors will be equipped with a self- latching device with positive mechanical latching/locking installed a min. 54" above the threshold. If this option is selected, submit plans showing all types and location of all perimeter protection. The plans must also show the location and type of all openings, and the hardware type for each location. (Submit Manufacturer's Specifications). In accordance with the Code, the pool may not be filled with water without compliance with the Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be presumed to be unsafe. I understand that not having one of the�above Installed will constitute a violation of Chapter 515, F.S ., and will be considered as comr Itting a misdemeanor of the second degree, punishable as provided in Section 775.082 or Section,' S. F.S . This form must be signed by the owner/agent and the prim tractor. CONT TOR'S SIGNATURE AND DATE /� Ow I !rjDAT E L IZ 4 (n Va- 4'� 121a /,a en 10 I I; `� mil l , .,, la - a, )MWTELE GU ►A My MwIssioN @ FF 0 87 EXPIRES: July 4,2D17 Bided Tin Nm Pubra Umle -bm , v Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 "r-1. (305) 795.2204 (305) 756.8972 KNOW ALL MEN. BY THESE PRESENTS: WHEREAS, the undersigned L_ i (-� Ck �n Gv -k L is /are the fee simple owner(s) of the following described property situated and being in Miami Shores Village, Florida Address: W i 10C1 0 ' ° A,JeAl ��. Whereas, the undersigned owner(s) L-% 0 Gt l"l -z- desire to utilize said Lot(s) as a single building site, and the undersigned owner(s) do(es) hereby declare and agree as folkm: I. That the property will not be used in violation of any ordinances of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. II. That the purpose of the covenant is to induce Miami Shores Village to issue a permit for a pool where the required enclosure is not on the subject property where the pool is located. III. That if any of our adjoining neighbors remove any portion of their fence or wall, or if our/my property shall fail to meet code requirements for pool barriers, we, as owners will immediately install a protective enclosure to meet code requirements and will obtain a permit for such fence. IV. That, Uwe, as owner(s) hold Miami Shores Village harmless for any negligence or injury that results from not having the enclosure. V. If enclosure belongs to said property, I agree to maintain & or replace said enclosure in the event that is damaged or removed by any case. NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant the use, enjoyment and title to the above property and shall constitute a covenant running with the land and shall be m the undersigned, his/her successors and assigns and may only be released by Miami Shores Village, or its in ac cordoce of said Village then in effect. i ba rti SIGN & PRINT ✓) OWNER SING & PRIM I Hereby Certify that on this perso �awy b efore me I4 N1 a 0 m f Z an es produces ID # nd he/she acimow ledge that he/she executed the forgoing, ly and voluntarily, for purposes there in expressed. ' lbSWORN TO AND SUBSCRIBED before me on this I`� day of A U (Revised 05009 /�I ' . EXPIRES;t,q�ycit X17 toad Tin Ratan Puma Umewbm Stopped Review Miami shores village Building Department 10050 N.E2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit NoBPP13 -1626 August 7, 2013 Page 1 of 1 Plumbing Critique Sheet 1 FBC 107 -1 Provide health dept approval Ozzie Diaz Plumbing Chief Inspector Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Stopped Review Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit NoBPP13 -1626 August 7, 2013 Page 1 of 1 Plumbing Critique Sheet 1 FBC 107 -1 Provide health dept approval Ouie Diaz Plumbing Chief Inspector Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Date: -� - Z3 _ --1) Permit No: ?" 13 - 1 r,, Z t_ ji - t3 - I Plumbina Critiaue k �C< I Gq -1 �'IZG Q (0 L I L-T(J 0 P I. Osvaldo "Ozzie" Diaz Chief Plumbing Inspector Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Law KAM - 305-5. LmJ -:;. y, i a� �. µ"ms` R=263W j La39 24' Tan24gi' I IZ� w V V �I y lon JOHN MARRA & ASSOCIATES, INC. Professional Land Surveyors & Mappers 777 N.W. 72nd AVENUE SUITE 3026, MIAMI, FLORIDA 33126 TELEPHONE: (308) 262 -0400 1 FAX: (306) 262 -0401 W WWMIARRALANDSURVEYORS.00M MAP OF BOUNDARY SURVEY 10109 NORTH MIAMI AVENUE, MIAMI SHORES, FL 33180 F�1VCR+di4ts/ 11+IEIV�- NOTES: VISIBLE' ENCROACHMENTS LOCATED IN THE SUBJECT PROPERTY. N. 'MIA+MI:AVENUE .: -- 80, r0TAL:RfcFrr- '0f_wAY .� 56' ASPHALT PVMT: I ASPHALT o4 b 10'ASPHALT PVMT. -a* 0N.- _ I CL -B.C. ::: :: ::::::: �0' LONG ' FLP.1/2' — — — — — — — — — — LOT -15 - -- NO CAP BLOCK -11 O� IB.q `pFi�IFIC;q`�R� LL dd Of NO. Ono O �' STATE OF LEML DESCRIPTION: LOT 13, LESS THE NORTH 5 FEET AND LOT 14, BLOCK 11, AMENDED PLAT OF MIAMI SHORES SECTION No. 1, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 10, PAGE 70, OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. CERTIFICA710M. DRAWN BY. DA SCALE: PL 0412512013 JOB NO: 13- 001529 -1 ., OR10P �C LAS L.B.# 7806 SEAL LINA GOMEZ PEREZ MENA & GONZALEZ, LLC. OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY SPACE COAST CREDIT UNION, ITS SUCCESSORS AND OR ASSIGNS, AS THEIR INTEREST MAY APPEAR SHEET: q F.IJP. 11r Ng C" I �• N� i cz P: - I 10 _ CL i PL V41 21.76' \ I ' C.L.F. \ \ \ \ i ' C.L.F. WATERS \ I 220 N L�J I PUMP An i m ;w. 28.36' � C C rr n C.LF O I 1.11' CL O to ..I 13.3T j ca W.F. 1.00' CL. LOT- 14 LOT -13 nt BLOCK -11 I LESS i g Z BLOCK -FEET o I j � I I I � ASPHALT o4 b 10'ASPHALT PVMT. -a* 0N.- _ I CL FLP.1/2' — — — — — — — — — — LOT -15 - -- NO CAP BLOCK -11 O� IB.q `pFi�IFIC;q`�R� LL dd Of NO. Ono O �' STATE OF LEML DESCRIPTION: LOT 13, LESS THE NORTH 5 FEET AND LOT 14, BLOCK 11, AMENDED PLAT OF MIAMI SHORES SECTION No. 1, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 10, PAGE 70, OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. CERTIFICA710M. DRAWN BY. DA SCALE: 1"=20' FIELD DATE: 0412512013 JOB NO: 13- 001529 -1 ., OR10P �C LAS L.B.# 7806 SEAL LINA GOMEZ PEREZ MENA & GONZALEZ, LLC. OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY SPACE COAST CREDIT UNION, ITS SUCCESSORS AND OR ASSIGNS, AS THEIR INTEREST MAY APPEAR SHEET: 2 OF 2 JOHN MARRA & ASSOCIATES, INC. 9 Professional Land Surveyors & Mappers 777 N.W. 72nd AVENUE SUITE 3026, MIAMI, FLORIDA 33126 TELEPHONE: (306) 262 -0400 1 FAX: (306) 262 -0401 VVyW jEL4kRRALANDSURVEYORS.00M LOCATION SKETCH SCALE =ALTS. A . ARC. A/C . Eta C ommu FR DAD A.B.a ARC 11T A.a.- ALW RODS' A.S.- ALWDUt AMD AWN. • ABDI;?W s B.C. BIAM CSR Buzzom B.C.R.- 8aDAMM COMM FXCCWM B.O.B.. RUN Or BFARIWO (c); cALCE7A0ND C.B.a CAWCR BASIS C.B.B.- CCIFCFAM BLOGN BTC?ODIE C.B.W.- CONCIOW BLOCS FALL Ca. - CBCSD CN.a.a CW= REARIIET CN.L.. CXOBD Lwow cL.a CLEAR C.O. - CERM our C.L.T.- cLmw zm F C.M.a . C9AIDL JAZWACNA= EAR Cam.- COBS C.U.P.. V?iat?Y DOLE C.D.- Cry FM= C.H.. Crimm am C.W.. COBCFM RALR D.a.- Annaor imnew D.K.R.- VRAMVM jAnrzRw= F ZILTVJIW ��. •ate no - BLECINw BOP: Tc 'FRANSIVIUM PAD aZEYBT=ff BAM, m ANCROACIUMM F.H. • ETAS T.I.P.. BODRD Mtw DZBB' g.I.a.- law am F.F.B. - SMUM ED TLODR ZR A?IGN F.N.D. - samw SUITE A DISK BT.- Sam FBTB.a SIMERAL HIMORAL MISURANCR istaguM F.W.. BMW NAIL N.a LIIYBT Oa (AmrGw) IS.AM.a zxwwHB AND BGRES8 FASDdNP W3. C. V.- Matrallum Cann= VALVE L.B.a LICEWBED LiU81TAES8 Z.D.a PS4NT DOZE L.F.H.- Z 1121ST SZOOR F&EVATION • THIS Stfla YIs VIEW OF SUBJECT PROPERTY 10109 NORTH MIAMI AVENUE, MIAMI SHORES, FL 33180 L.M.E.- ZM XLZN2Z== EA88MBlPT a )COMM (tea iWABGGIED DZSZUM J= BOX M.D.C.R.a LII'AfTi DADS COUNTY l M.B. - F FABFEPT K.N.- 1 S.A.D.- BYiP 8 DART OF NBVD - BaTIOBAL GrODETIC VE TCU DAM N.?.8.- NOT To BCALE @ or BO.- 0/S a OFF= O.N. - OVARRM O.B.L. - OVF38EAD VZ=71 LIFNB O.R.B.- OnTCIAL BECORDB B= O.V.N. - OVERSAM FVJdT.a PAVANNT DZ.a FZANT&R D.y.a pg[ Y LTw- D.C.O.- DOINT OF COWV= CURVATURE D.C. - POINT OF CURVATURE D.O.T.= ROUT OF ?AEQFNCY D.O.C.. POEM OT C D.O.B.a VOMIT CIF BEGMIUMIG D.B.C.: P018T OF REVERSE CURVATURE 1WY - PARIGM D.R.M. - P2 PP MCFAF2210E M IIII) W D.L. 6.a PBOFEBSIORAL LARD SUrA= D.D.a Pam FM F.D.S. - POOL VMdF BLAB P.U.E.a PUBLIC DTiLITY 8A8E1ff11' (a). RECORD DIS�ACE R.R. - BAIL ROAD RES.a E B/W = arGr -OF-law BAD.- RADZUS OR RADIAL am a BMW B.O.E.- ROOF OVERRASO F.BSEMM 888.- 8802TON STY.- Slaw SIN.- 8zamem S.I.F. - BUT ZRw DIVE 8 - SOD= B.F.- SCBBE= FORM S.V. - OEM VALVE •- T a ZUFM ! TB a ',Z.EFAMIN BOOTH I USEINOBTAUMG TITLElNSURANCEANDFMNOINQAAD) SHOULD NOT BE USFOFOR TITLE N01I. MVETO BEMADE TO DETE)VAW RECORDED INSnL*5 TS, IFANY, • BOUAVARY SURVEY MWADRAIUM AMY ORAORAPMCMWASS 'NTA17ONOF THE SURVEY WURXPERF IEWINTHE FWA COULD BSORAMATASHOWSCALEAAD URNOTTOSCALP' THE WALLSORP &XMMAYBEEXABCA:RATEDFOR CIAMTYPLIIPOSS& •EASSOMAS SHO MDAFL PER PLAT BOOK UNIM DEPICTW OTH • TIN TOM 110VORGAGNMEW U84MVISIBLEANDABOVEGiRO/ANDfiNCROACHIMAIM •ARLYBTOM SHALL VLRIFYZOMNS REQULATIM, RESTRICTIONS, SETBACKS WL. BEILWMSMEFOR SUBNITTWGS PLDTPLANSAMCOIRECTBVrTC MMWON FOR MPPROVAL FOR AUTHORM471OWTO THE PROPERAUTHONVIESINAIM CTRUCTIOAL • UNLESS OTHIN ME NOISQ, THIS FIRM HAS AWATTLONFTEDTO LOCATE F007MGANWCRFOL &VATIOMS. 0F9xCffOi NOT a THIS PLAN OF SURVEY, HASSM PREPARED FOR THE EMUSWE USE OF THE SWUM 94M RMSOAyIMCEM047E WES NOT DGEND TO ANY 10MANED PARTY. • x COmT7Y 48800 /PANELWCd /BUFPONL, LAOTEOFFTRAC 00H1/aO09BASEFLOODElEVaTIOAt NUl THE SUILECT TYD OESAWLIEINASPECIAL ,FLOODMZMDAREA TITLE COMPANY A U n � r ,Y?� h ' I �, �` �1 r(11 �� Er l DRAWN BY. I DA ' UNDERWRITER W.B.M.- '1B1ID0xAaIf B1 � TSB a TRgFBTC SIL$1WL BO$ &� TV a TRAFFIC BIGIDAL FOIE 13 TIP - TOff V.E.• U.D.- N.M. W. F. a WOOD n . W.D.a WDOO JUL 1 9 LSD I� If A.= WOOD ROOF' W.V.a EATER VALVE --S aIDNDa; C�B?B 0 a DFMWA LEGEND - OVERBEAR DTILITY LTIM - CO IC21M Bro= FALL -� -�_ a zi>cN FTL= a O.IB - E%Ig?ISp EZ.EVATICNB BY SURVEYOR'S NOTES. 1. IFSHOWA; BEARUMBAREREPOMED TOANASSUNEDA 5UMW BYSNDPLATIN?W - DESC7BPWX OF THE PROPERTY, IFNOT, BEARDMS ARE THEN REFERRED TO COLWn; TDVANSHO+LRAPa Z THE CLOBURi X niff BOUIMW SURVEY IS ABOVE 19500 FT. I CERTIFICATE OFAV7710RIZATIONLS 6 7W& 4. NORTH IS BASED CNNPLATNORM SURVEYOR'S CERTIFICATION: I HEREBY CERTIFY,• THIS IMAWARY SUIMY 'OFTHEPROPERTYCESCRIBEDHEREM,, HAS RECENTLYBEFJV SL0IVEYEDANDORAYIN UA0MMYSLMVISW AND COMPLIES VATH THE AM UN LAND SURVEYORS Di CHAPTER 61-17, FLORIDA ADMINISTRATIVECODEPURSUANlTO4 78027, FLORIDA STATUTES. 0412512013 CARLOS ISARRA (DATEOFPIEL wow PROFESSIONALLANDSURVEYORAw 6770 STATBCN:FLOISGW (NOT VALID VBTHOUTTHE XMMTU)MAND D EOR/SIAIAI. RAISED SEAL OFARDJOA LICENSED SURVEYOR AND MAPPER). REVISED Oft - REVISED OAt FIELD DATE. M&2013 �77� JOB NO: 13- 001525 -1 * OLD U BLI C SON" � � °° Y * ** ** SHEET: 1 OF 2 L.B.# 7806 SEAL. � r �!M PERMIT Mf AflMI S i APPROlED ZONING STRUCTULAL ELECTRICAL PLUMBING j MECHANICAL BLDG. "Z y [!.:Zj "tip /3 16026 swap JUL' 9 -a i3 ------------ onsnNG s� WOOIATI I 130.00 A P OVED j .� RATES 70 HAV2 5ELP LGY.KIW6 MLMfj -DARE C LINTY W_&- H DEP/iR 11�nG��. I009N6 DFVIG@ T MEMIAMSK 6AI AT NOT x E)WNG *0 CFWN LINK FENCE q ' ( �) =5 70M 39° ASM GRADE PM PIG (J CO C.� TOIG R4IOI.R.IB PERMIT 0. '- ` PRO OV 13Y HoMecHNIR U+mER L SEPARATE PERM CA 4' II'-O° _ I 88'-4° iii �fd_,�� VILLAGE I k�5 W) °o RV DATE p Iii a_ � ��� I� NEW CONCR D2CK 5U1 � • n 250 5F ,7 L , SUBJECT TO COMM STATE AND MUNTY LEGEND P.E POOL EQUIPMENT P.H POOL EQUIPMENT FE-9-1 ELECTRICALME'fM E P ELECTRICAL. PANEL AJC AIR CONDITIONER 't) ' ®,3 1TH ALL FEDERAL 6'-0° EM5TING 6RICK PAVER5 ONE STORY C55 RESIDENCE #10109 ALL DOORS AND ViNDOG PROVOIN6 DIRECT AC4EM FROM 7W MMC TO THE POOL. K" BE 2QAPED MYTH AN EW HAS A MRM" SaW PRE89URE RATRO OF 805 A AT 10 FEET. IN AL40R0AW,9 MYTH FS.6. 4242.IT.IA PROW= BY HOPSOHNIER a PROMED SW ,-, - NPARATE BMW NV C AIN =FENCE 130.00 LEGAL DE5CRIPTION: LOT 13, LM5 THE NORTH 5 FEET AND LOT 14, BLOCK 1 1, AMENDED PLAT OF MIAMI SHORE5 SECTION No. 1 , ACCORDING TO THE PLAT THEREOF, A5 RECORDED IN PLAT BOOK 10. PAGE 70, OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. X EXISTING PLANTER .2 EXISTING CONCRETE AALKWAY EXISTING CONCRETE DRIVEWAY (D SITE PLAN N SCALE: 1/16 " = 1' -0" O 0 LO 0) V a Fw- U s 0 LLI I.1-I } pl, FA SWIMMING POOL NAME: ROLANDO 50LAR ADDRESS: 101011 N MIAMI AVENUE CITY: In LOT: 6'-0° EM5TING 6RICK PAVER5 ONE STORY C55 RESIDENCE #10109 ALL DOORS AND ViNDOG PROVOIN6 DIRECT AC4EM FROM 7W MMC TO THE POOL. K" BE 2QAPED MYTH AN EW HAS A MRM" SaW PRE89URE RATRO OF 805 A AT 10 FEET. IN AL40R0AW,9 MYTH FS.6. 4242.IT.IA PROW= BY HOPSOHNIER a PROMED SW ,-, - NPARATE BMW NV C AIN =FENCE 130.00 LEGAL DE5CRIPTION: LOT 13, LM5 THE NORTH 5 FEET AND LOT 14, BLOCK 1 1, AMENDED PLAT OF MIAMI SHORE5 SECTION No. 1 , ACCORDING TO THE PLAT THEREOF, A5 RECORDED IN PLAT BOOK 10. PAGE 70, OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. X EXISTING PLANTER .2 EXISTING CONCRETE AALKWAY EXISTING CONCRETE DRIVEWAY (D SITE PLAN N SCALE: 1/16 " = 1' -0" O 0 LO 0) V a Fw- U s 0 LLI I.1-I } pl, FA SWIMMING POOL NAME: ROLANDO 50LAR ADDRESS: 101011 N MIAMI AVENUE CITY: MIAMI 5HORE5, FL 33180 LOT: BLOCK: SUB. I I MIAMI SHORE5 5EG I OWNER PHONE: (305) 52"1 -15'10 DRAWN BY: DATE: M.CALIL O-18 -2013 'f REWORK No. DATE DESCRIPTION REVISIONS No. DATE DESCRIPTION EDUARDO BARRETO PROFESSIONAL ENGINEER P.E. LICENSE NO. 69677 7355 SW 89ST#422 MIAMI, FL 33156 PHONE: 086) 239.1808 ��0l89 ®O /fs� to�Q.�ETO O0000 �: �5 • :;v� '2 = 0. Q• CA. • .w_ � : �j � •'' m oo� F Esc� e,% ,811 sit® SITE PLAN PAGE 1 of 5 SWIMMING POOL AND SPA GENERAL SPECIFICATIONS POOL MODEL: POOL SHAPE: GEOMETRIC POOL DEPTH: 3' -0" TO 5' -0" POOL DIMEM51ONS: 8' -0" x 3G' -O" SWIMMING AREA: 374 S.F. POOL CAPACITY: 1 1,220 GALS SPA SIZE: N/A SPA HEIGHT: N/A SPA CAPACITY: N/A STEP TREAD DEPTH: 15t= 1' -0 ", 2nd= P -O ", 3rd= 1' -0" SPA DECK STEPS: N/A L.F. SWIM OUT: P -8" x 8' -0" CONSTRUCTION MATERIALS INFORMATION CONCRETE: _ CY 11 COPING: I N/A TILE: 102' -0" L.F. 11 CEMENT DECK: 1 250 S.F. DECO-DRAIN: N/A POOL EQUIPMENT AND LIGHTING COMPONENTS SKIMMER: YES (x I) NUMBER OF RETURN LINES: 3 MAIN DRAIN TYPE: 2 ANTI - VORTEX HANDRAIL: N/A PUMP SIZE AND MODEL NUMBER SUPERFLO PUMP 1.5 HP POOL FILTER TYPE: 100 SQ FT CLEAN CLEAR CARTRIDGE FILTER POOL LIGHT: PENTAIR 5G LED COLOR POOL LIGHT SPA LIGHT: N/A POOL HEATER: N/A SALT CHLORINATOR: N/A ADDITIONAL WATER FEATURES AND COMPONENTS SHEER DESCENT: N/A MASSAGE JETS: N/A ROCK WATERALL: N/A DECK JETS: x2 (SEE LOCATION ON PLAN) AQUA ACCENTS: N/A MOSAICS: N/A NOTES: - DIAMOND BRJTE STANDARD COLORS ONLY- BWE - LAY IN AREA 4' -0" x 10' -G" REQUIRED POOL SETBACKS FRONT: 75' -0" REAR PROPERTY LINE: 7' -G" SIDES: 12' -G" FROM HOUSE REAR: 5-0" DECK SETBACKS REAR: 5-0" SIDES: 10-0" NOTES : MUNICIPALITY: MIAMI SHORES POOL GENERAL NOTES. 1. SWIMMING POOL WAS DESIGNED ACCORDING TO F.B.G. 2010 STANDARDS 424 AND AN51INSPI3, ANSMFI -G 2. REINFORCING BARS TO BE NEW 51U.ET GRADE CONFORMING TO ASTMA -G 15. GRADE GO 3. POOL BUILDER TO FOLLOW FLOTATION ANALY85 AS INDICATED. 4. ALL POOL PIPING TO BE PVC SCHEDULE 40 AND BEAR THE NF5 APPROVAL 5. DI5PO54 OF POOL WATER WITHIN LOT LINES AND SUCH FOUNDING SHALL NOT PERSt5T,,4 FOR MOIRE THAN ONE HOUR DISCHARGE. KF G. WATER SUPPLY AND DISPOSAL SHALL BE INSTALLED IN A WAY50 T 1A THERE 15 NO0 CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM: 7. -GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA FOUR TIMES THE AREA OF SUGfION UNE. 8. HAIR AND LINT STRAINERS SHALL HAVE REMOVABLE SCREEN WITH A FREE AREA THREE TIMES THE AREA OF THE SUCTION LINE (4 -DIA. MIN.). ELECTRICAL NOTES. 1. INSTALL WIRING AND DEVICES AS INDICATED IN POOL DATA SHALL FURNISHED ELECTRICAL. SERVICE AT EXISTING ENTRY. INSTAL. DISCONNECT SWITCH AT MOTOR IF NOT WITHIN So OF FUSED SWITCH AT SERVICE POINT. ELECTRICAL LIGHT CONNECTION TO COMPLY WITH NEC GGO -1575 ART. G80. 2. ALL METALLIC CONDUITS, PIPING SYSTEM, REINFORCING STEEL, UGTHTING FDMRES AND FD(TURE HOUSING, METAL PARTS OF LADDERS, AND THEIR SUPPORTS, SHALL BE BOUNDED TOGETHER AND GROUNDED TO A COMMON GROUND. BOUNDING CONDUCTORS SHALL NOT BE SMALLER THAN #8 COPPER. 3. NO OVERHEAD OPEN WIRE OVER POOL WATER. RECEPTACLES WRIT I C' OF WATER. BARRIER GENERAL NOTES: FBC R41 O 1.17.1 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER COMPLYING WITH FBC R 4101.17. 1.1 TO 4101.17.1.8 THE BARRIER MUST BE PLACED AROUND THE PERIMETER OF THE POOL AND MUST BE SEPARATE FROM ANY FENCE, WALL, OR OTHER ENCLOSURE SURROUNDING THE YARD UNLESS THE FENCE, WALL, OR OTHER ENCLOSURE OR PORTION THEREOF IS SITUATED ON THE PERIMETER OF THE POOL, 15 BEING USED AS PART OF THE BARRIER, AND MEETS THE BARRIER REQUIREMENTS OF THIS SECTION. (F.B.C.424.2.17.1.12) (F.B.0 R4101.17.1.12) REMOVEABLE CHILD BARRIERS MUST BE PLACED SUFFICIENTLY AWAY FROM THE WATERS EDGE TO PREVENT A YOUNG CHILD OR MEDICALLY FRAIL ELDERLY PER50N WHO MAY MANAGE TO PENETRATE THE BARRIER FROM IMMEDIATELY FALLING INTO THE WATER. SUFFICIENTLY AWAY FROM THE WATER'S EDGE SHALL MEAN NO LESS THAN 20- (508mm) FROM THE BARRIER TO THE WATERS EDGE. DWELLING OR NON-DWELLING WALLS INCLUDING SCREEN ENCLOSURES, WHEN USED AS PART OR ALL OF THE BARRIER AND MEETING THE OTHER BARRIER REQUIREMENTS, MAY BE AS CL05E TO THE WATERS EDGE AS PERMITTED BY THIS CODE. (F.B.C. 424.2.17.1.13) (F.B.C. 8424.2.17.1.13) A WALL OF A DWELLING MAY SERVE AS PART OF THE BARRIER IF IT DOES NOT CONTAIN ANY DOOR OR WINDOW THAT OPENS TO PROVIDE DIRECT ACCESS FROM THE HOME TO THE SWIMMING POOL(F.5.C.424.2.17.1. I4) (F.B.C. R424.2.17.1.14) ALL DOORS AND WINDOWS PROVIDING DIRECT ACCES FROM THE HOME TO THE FOOL MUST BE EQUIPPED WITH AN EXIT ALARM THAT HAS A MINIMUM SOUND PRESSURE RATING AF 85dB A AT 10 FEET. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE DRAWING AT THE JOB SITE REPORTING ANY INCONSISTENCY TO THE ARCHITECTJENGINEER PRIOR TO ANY CHANGE REQUIRED. OTHERWISE THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY OF SUCH CHANGES AND ANY REQUIRED REVISION TO THE PLAN. EXCEPTION: A SWIMMING POOL WITH AN APPROVED SAFETY POOL COVER COMPLYING WITH ASTM F 1346. 501L STATEMENT. PER VISUAL INSPECTION 501L AT THIS SITE REVEALS SAND AND LIMEROCK WITH AN ALLOWABLE BEARING CAPACITY OF 2000 PSF. AT TIME OF D(CAVATION A LETTER WILL BE SUBMITTED BY THE ENGINEER ATTESTING THAT THE SITE HAS BEEN EVALUATED AND THE SOIL CONDITIONS ENCOUNTERED ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASED. LEGAL DESCRIPTION: LOT 13, LESS THE NORTH 5 FEET AND LOT 14, BLOCK 1 1, AMENDED FIAT OF MIAMI SHORES SECTION No. 1. ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 10, PAGE 70, OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA v s SWIMMING POOL NAME: ROLANDO 5OLAR ADDRESS: 101001 N MIAMI AVENUE CITY: MIAMI SHORES, FL 33180 rem : • 5HORE5 We, (305) 52"1 -1570 M.CAL I L 1 07 -18 -2013 REWORK No. DATE DESCRIPTION REVISIONS No. DATE DESCRIPTION EDUARDO BARRETO PROFESSIONAL ENGINEER P.E. LICENSE NQ 69677 7355 SW 89 ST#422 MWA, FL 33156 PHONE: (786) 239.1818 0'. IF �•'••�P� O FEW GENERAL NOTES PAGE 2 of 5 N OT E: ALL POOLS AND SPAS MUST BE EQUIPPED WITH ANTIVORTEX DRAIN COVERS IN COMPLIANCE WITH VGB ACT AND A5ME/AN51 1 12.19.8 �Z PLUMBING LAYOUT PLAN SCALE: NT5 ADJUSTABLE COLLAR I '- " PERFOR BASKET 2" TREAL HYDR05TATIC RELIEF 2 1/2" PIPE 5UCf1ON LINE SKIMMER LINE " VACUUM LINE 112" POOL RETURN LINE 112" POOL MAIN DRAIN LINE "DECK JET I " DECK JET 2 JIP. * DETAIL LEGEND 1. ANTIVORTEX MAIN DRAIN N 1) 2. SKIMMER 3. VACUUM WITH SAFETY VAC LOCK COVER 4. INLET (x3) 5. 5WIMOUT (SEE DETAIL) G. SWIMMING POOL LIGHT (x 1) 7. GFV WP G' MIW20' MAX FROM WATER EDGE 8. LAY-IN AREA 9. DECK JEr5 (x2) 10. UMBRELLA HOLE ANTIVORTEX ANTI ENTRAPMENT DUAL MAIN DRAIN DETAIL 5KIMMER DETAIL ACCORDING TO (424.2G.G.3)(424.2G.G.4) (424.221.2). SUCTION INLET5 5HALL COMPLY WITH AN51 /AP5P -7 2000 4 FBCR20105ECnON R41 OI.G.G DISTANCE CHART FOR HYDR05TATIC RELIEF VENT PUMP HORSEPOWER 11,220 MAX D15TANCE IN FEET 0.75 HORSEPOWER G° (MIN) CONC. 1.0 HORSEPOWER 32.69 FEET ALL AROUND 40.86 FEET 2.0 HORSEPOWER DRAIN SUMP. 2.5 HORSEPOWER 73.54 FEET 9 3 AROUND )— DATES DRAINS ® 10- QC 07 -18 -2013 REWORK E.W. W /18° MIN LAPTO DATE DESCRIPTION FLOOR REI NFORCING 2 1/2" PIPE 5UCf1ON LINE SKIMMER LINE " VACUUM LINE 112" POOL RETURN LINE 112" POOL MAIN DRAIN LINE "DECK JET I " DECK JET 2 JIP. * DETAIL LEGEND 1. ANTIVORTEX MAIN DRAIN N 1) 2. SKIMMER 3. VACUUM WITH SAFETY VAC LOCK COVER 4. INLET (x3) 5. 5WIMOUT (SEE DETAIL) G. SWIMMING POOL LIGHT (x 1) 7. GFV WP G' MIW20' MAX FROM WATER EDGE 8. LAY-IN AREA 9. DECK JEr5 (x2) 10. UMBRELLA HOLE ANTIVORTEX ANTI ENTRAPMENT DUAL MAIN DRAIN DETAIL 5KIMMER DETAIL ACCORDING TO (424.2G.G.3)(424.2G.G.4) (424.221.2). SUCTION INLET5 5HALL COMPLY WITH AN51 /AP5P -7 2000 4 FBCR20105ECnON R41 OI.G.G DISTANCE CHART FOR HYDR05TATIC RELIEF VENT PUMP HORSEPOWER 11,220 MAX D15TANCE IN FEET 0.75 HORSEPOWER 24.5 1 FEET 1.0 HORSEPOWER 32.69 FEET 1.5 HORSEPOWER 40.86 FEET 2.0 HORSEPOWER 54.47 FEET 2.5 HORSEPOWER 73.54 FEET 3.0 HORSEPOWER 78.98 FEET DATES M.CAL I L POOL DATA POOL CAPACITY (IN GALLONS) 11,220 FILTER CARTRIDGE 100 (5Q.FT) 21" FILTRATION RATE (GAL/MIN* PM) 50 POOL TURNOVER MRS) 2.88 POOL SURFACE 374 S.F. POOL PERIMETER 102 FT HOUSE TIMER BOX POOL LIGHT BOX y' POOL DRAIN EOC'; SKIMMER UMW oo� WASTE VACUUM �� POOL RETURN ILTE A a DECK JET LINE I 1 DECK JET LINE 21 PLUMBING EQUIPMENT PLAN 5CALE: NT5 PRESSURE GAUGER PRESSURE RELIEF VALVE TIMER 1.5 HP POOL WITH HAIR 4 LINT STRAINER MODEL 5UPERFLO AT 60' - 35 GPM - 5.52 VEL.FT.PERSEC. CARTRIDGE FILTER MODEL PENTAIR 1 1 100 5Q.FT. SWIMMING POOL NAME: ROLANDO SOLAR ADDRESS: 101001 N MIAMI AVENUE CITY: MIAMI 5HORE5, FL 33180 LOT: BLOCK: sue. 11 MIAMI SHORES SEC I OWNER PHONE: (505) 501? -1570 DRAWN BY: DATES M.CAL I L 07 -18 -2013 REWORK No. DATE DESCRIPTION REVISIONS No. DATE DESCRIPTION EDUARDO BARRETO PROFESSIONAL ENGINEER P.E. LICENSE NO. 69M 7355 SW 89STOn MIAMI, FL 33156 PHONE: (786) 239.18M VAE a :0 i2= e ir iJ • • 0 O• Lu sp �• , 3 FEET MIN. 5PACWG� PLUMBING PLUMBING ISOMETRIC �" ,•��G� SCALE: NT5 PAGE 3 Of 5 . T CA)m. INTERLOGKM PAVERS G1.EAR G01/E POR THlrav�s 5t3^ NOTE a I WFLL COMPACTI) FILL FOR THICKNESS .I.. 5EE NOTE @ I I' -0° RADIU5 DEEP END #3 Q 10° EA. WAY SIDE 4 R/ 5CT7. TYPICAL. 57EEL TEXT FORM OR KRAFT BOARD TYPICAL WALL SECTION SCALE: 3/811 = 11 -0'1 IS" to 24 "MAX d WATER LINE SWIMOUT DETAIL NOT TO EXCEED 10% OF POOL PERIMTER SCALE: NTS 12° 12° 1 G, WATER UNE 9 9 COLOR I I.GO CONTRAST 5.83' TILE 5.77' CONTINUOUS @ 8.00 m C @3 @ 10' qC -2.00 TYPICAL fV —TTI SWIMOUT DETAIL NOT TO EXCEED 10% OF POOL PERIMTER SCALE: NTS 12° 12° 1 G, WATER UNE 9 9 FLOTATION ANALYSIS. DECK LEVEL. ELEVATION I I.GO STEEL TO RUN 5.83' LOW POINT POOL LEVEL 5.77' CONTINUOUS @ 8.00 m C AREA OF STEFS -2.00 HYDR05TATIC UPLIFT 0.23' FOR SPACING PNEUMATICALLY PLACED CONC. M.CALIL TOP SEE TYP WALL WALLTHICKNE55 G. G° SECTION THIS G° STEP A) (12° MAX). RISER HEIGHT MLLST BE UNIFORM. B) ; 2° FROM THE UNIFORM RISER HT. C) CONTRASTING TILE AT EDGES. D) 240 SO IN. MINIMUM AREA OF FIRST STEP. TYPICAL STEPS DETAIL SCALE: NTS FLOTATION ANALYSIS. DECK LEVEL. ELEVATION I I.GO POOL DEPTH 5.83' LOW POINT POOL LEVEL 5.77' FLOOD CRITERIA 8.00 F.C. DEPTH LEVEL 2.23' LE55 HYDROIMRS ICAL -2.00 HYDR05TATIC UPLIFT 0.23' NOTE 0L' OWL THICKNESS) PNEUMATICALLY PLACED CONC. M.CALIL TOP BOTT. WALLTHICKNE55 G. G° FLOORTHICKNE53 G. G° 501LBEARINGCAPACITY 2000P5F SOIL STATEMENT: PER VISUAL INSPECTION SOIL AT THIS SITE REVEALS SAND AND UMEROCK WITH AN ALLOWABLE BEARING CAPACITY OF 2000 PSF. AT TIME OF EXCAVATION A LETTER WILL BE SUBMITTED BY THE ENGINEER ATTESTING THAT THE SITE HAS BEEN EVALUATED AND THE SOIL CONDITIONS ENCOUNTERED ARE SIMILAR TO THOSE UPON WHICH THE DESIGN LS BASED. POOL SURFACE: 374 SQ FT. POOL PERIMETER: 102' -0" i tf POOL PLAN Gz SCALE: 3/32" = P -011 c 6 ®DECK PLAN Z SCALE: 3/32" = P -011 SWIMMING POOL NAME: ROLANDO SOLAR ADDRE55: 10101 N MIAMI AVENUE CITY: MIAMI SHORES, FL 33150 LOT, BLOCK; SUB. MIAMI 5HORE5 5EG I OWNER PHONE: (78(b) 271 -5346 DRAWN BYs DATE: M.CALIL 07 -I5-2013 REWORK No. DATE DESCRIPTION REVISIONS No. DATE DESCRIPTION EDUARDO BARRETO PROFESSIONAL ENGNEER P.E. LICENSE No 69677 7355 SW 89 ST#422 MIAMI, FL 33156 PHONE: (786) 239.1808 ARETO ® ® ®i eJ%�OP` .. • p Q; CD .. .. .. �•••••••••• ®0 0 ®v % CONSTRUCTION PAGE 4 of 5 LOAD CALCULATIONS • ' ` GENERAL LIGHTING: 1,904 5.F. X 3 WATTSOF + 3,000 WATTS- 8,712 WATTS GENERAL APPLIANCE5 4 WATER HEATER= 28,000 WATTS POOL PUMP AT 100% = 2,900 WATTS POOL LIGHT AT 100 % - 35 WATTS TOTAL = 39,647 WATT5 FIRST I OKw AT 100% = 10,000 WATTS N REMAINDER 29,647 WATTS ® 40 % - 11,859 WATTS TOTAL LOAD ® DEMAND FACTOR- 21,859 WATTS AC OR HEATING AT 100% - 10,000 WATTS TOTAL CONNECTED LOAD = 31,859 WATTS/ 240 VOLT5 = 133 AMT'S ELECTRICAL POOL EQUIPMENT INCLUDED I SALT CHLORINATOR NO 2 POOL HEATER NO 3 SPA HEATER N/A 4 POOL PUMP 1.5 HP 5 EXTRA POOL PUMP NO G POOL LIGHT 35 WATT 7 SPA LIGHT N/A JUNCTION BOX PRE - CAST COPING w W -O" MIN. Z w F LINE '.:. .. FEE/l/1111 FEW M2 3 3600 4 POINT CONNECTION ?' #8 AWG COPPER BARE BONDING to F 18° -24° FROM POOL WALL m (BONDING POINTS TO BE TOP OF EQUIDISTANT AND CENTERED. FIXTURE SEE PLAN BELOW] I ° Pvc u: -:; ' 1— PLASTIC LIGHT NICHE (12 VOLT) BONDING AS SHOWN. EQUIVALENT TO REQUIREMENTS BY NE: GW.2G (SEE PLAN FOR LOCATION) UNDER WATER LAMP SECTION SCALE: NTS PUMP GRID 50. T POOL 18 ATTACHMENT _ POINTS i EQUIDISTANT BONDING GRID PLAN SCALE: NITS JUNCTION BOX a PUMP SWITCH 300 W TRAN51FORMER TIMER COMBINATION 0 JB ,AF J-0 GFI RECEPTACLE G MIN 20' MAX. FROM WATER LINE POOL PUMP 1.5 HP, 230V GFCI PROTECTED AS PER 680.228 NEC TAMPER RESISTANT NEC 40G. I I AND FBC(E) 403.9 2 # 12 THHN 2P 20 PAM 2 # 12 THHN IF 15 AMP I # 12 THHN CV GROUND 0 JB 35 W POOL LIGHT 300 W TRANSFORMER POOL ELECTRICAL SCHEMATIC 3 # 2/0 THW CU. I # G THNN CU. GRND. IN 2' C. 10109 N MIAMI AVENUE CITY. MIAMI 5HORE5, FL 33150 200 A MAIN EX15T MOM SUB. METER COMBO 11 MIAMI SHORES SEC I CAN EXIST. DRAWN BY: J M.CAL I L 0'7 -18 -2013 D(IST 200 A — DESCRIPTION ° ° O FFL PANEL o SERVICE POOL POOL REVISIONS No. PUMP DESCRIPTION HEATEF POOL 20A O A LIGHT ! 5 A 2' RGC FROM POWER COMPANY EDUARDO BARRETO PROFESSIONAL ENGINEER TRANSFER PAD 7355 SW 89 ST #421 MM, FL 33156 # 4 CONDUCTOR TO 20 FOOT I # 4 TW CU IN /4° COND. TO CAP. ,� SECTION OF FOUNDATION STEEL I a-O' DEEP GROUNDING # 5 FOUNDATION ROD - SW DIAMETER REBAR MIN. 20 FT. LONG HOUSE CONCRETE FOUNDATION A. ALL POOL ELECTRICAL WORK SHALL COMPLY WITH NEC 2008. B. NO OVERHEAD ELECTRICAL WIRING SHALL BE LOCATED WITHIN I O' OF POOL'S WATER EDGE UNLESS IT 18' OR HIGHER. C. PRIOR TO ELECTRICAL ROUGH, ELECTRICAL CONTRACTOR SHALL SUBMIT A REVISION TO THIS DRAWING SHOWING EXISTING SERVICE WITH ADDITIONAL LOADS, CALCULATIONS AND EXPECTED AS BUILD CONFIGURATION IF DIFFERENT FROM THIS DRAWING. D. GROUND ALL BOXES, LIGTHS, MOTORS, LADDERS, ETC WITH #8 GROUND WIRE. NOTE: G80 -25 (b) POOL LIGHTING FIXTURES AND RELATED EQUIPMENT SHALL BE CONNECTED TO (1) No 12. IT SHALL BE AN INSULATED COPPER CONDUCTOR AND SHALL BE INSTALLED WITH THE CIRCUIT CONDUCTOR IN PVC CONDUIT. JIiHLL I /It — I —V TH15 POOL 15 NOT INTENDED FOR DIVING MAIN DRAIN SEE DETAIL SWIMMING POOL NAME: ROLANDO SOLAR ADDRE55: 10109 N MIAMI AVENUE CITY. MIAMI 5HORE5, FL 33150 LOT: MOM SUB. 11 MIAMI SHORES SEC I OWNER PHONE: (786) 2'71 -5346 DRAWN BY: DATE: M.CAL I L 0'7 -18 -2013 REWORK No. DATE DESCRIPTION REVISIONS No. DATE DESCRIPTION EDUARDO BARRETO PROFESSIONAL ENGINEER P.E. LICENSE NQ 69677 7355 SW 89 ST #421 MM, FL 33156 PHONE: (786) 239.1808 ► ► ►►► t e II a ®, ®, ,� • .. O • P FE 011ie ELECTRICAL & POOL SECTION PAGE 5 of 5 9� sj Z® C3 ° o° b muslon: To protect, promote & improve the health of all people in Florida through integrated state, county & community efforts. (Genie Pools) 12940 SW 128 Street 201 Crossings, FL 33186 RE: Contingency Letter Application Document No: AP1115180 Centrax Permit Number: 13 -SC- 1486157 OSTDS Number: 10109 N Miami Ave Miami, FL 33150 Lot: 13, 14 Block: 11 Dear Applicant: August 05, 2013 Rick Scott Governor John H. Armstrong, MD, FAGS State Surgeon General & Secretary Subdivision: Miami Shores Section 1 This will acknowledge receipt of an application dated 07/25/2013 for a permit to use an existing onsite sewage treatment and disposal system located on the above referenced property. This permit is granted for the construction of a new swimming pool. There will be no increase in sewage flow or characteristics and no impact on the unobstructed area. From a review of your completed application, it has been determined your existing system is adequate for the proposed use. If you have any questions on this matter, please call our office at (305) 623 -3500. Sincerely, Betsy Lan e, Engineering Specialist II Carlos Icala Enclosures cc: Florida Department of Health www.FloridusHealth.com In DADE COUNTY TWITTER:HealthyFLA 1725 NW 167 St, Opa Locka, FL 33056 FACEBOOK:FLDepartmentofiealth PHONE: (305) 623 -3500. FAX: (305) 623 -3645 1 YOUTUBE: fldoh Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT PERMIT #: () ` 1 P 13— 1(o ?- (P DATE: fl d (NAME) o Contractor o. Owner oZrchitect Picked up 2 sets of plans and (other) fE(2— ,Address: 101 Qq � Iii. 1 C4.A'n % JQ From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DA PERMIT CLERK IN (Signature)