Loading...
RF-13-5019Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: JOB ADDRESS: BUILDIN City: Miami Shores Folio/Parcel #: Is the Building Historically Designated: Yes OWNER: Name (Fee Simple JAN Z,9 ag FBC 20 Permit No, _ �°���"�� Master Permit No. ROOF G NO �/� Flood Zone: Address: city: State: Zipse J� Tenant/I.essee Name: Phone#: Email: CONTRACTOR: Company Name: '12— v 6 ,?/ -3 - f Address: _ 52 � S -. &) 62?-:? ���l %_ City: k/ State: z- % . Zip: MziE Qualifier Name: lq- 4` ,�'r 7 `�_Ifl ' Phone # - State Certification or Re 'stration #: Certificate of Competency #: Contact Phone#:' S d % 5��� Email Address: DESIGNER: Architect(Engineer. Phone #: Value of Work for this Permit: _ Square/Linaw Footage of Work: y V:Fg Type of Work: DAddition DAlteration ONew �tepair/Replace ODemolition Descriptiop.:pf Work: z� ei!s� i Color thru tile: Submittal Fee $ Permit Fee $ � L) CCF $ CO /CC $ Scanning Fee $ b . Qa Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $—B, I .66 Bonding Q� y's Name (if applicable) 'Bonding Company's Address City State 4 Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate_ and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of , 20 _, by who is personally known to me or who has produced As identification and who did take an oath. Sip atcuref :2QZPc Contractor The foregoing instrument was acknowledged before me thisQR day oJ6070W( , 20 L�, by 1DQ /e• &./e/1 , who is personally known to me or who has produced / 7 f a YJ as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: 1 a/ .... III My Commission Expires: My Co u ry Puk, lc 8ta" Ot Flcdda 'loar►na ►� Feliciano My COMM!sslon FF 082783 EM*68 01/12/2018 APPROVED BY A ZF-�Plans Examiner Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised (y7 /10 /07)(Revised 06/10/2009)(Revised 3/15/09) -ROME ME us • . SECTION B-(Roof \ n rr � v ter.; T;n In■■■/t=: ■ ■62n/■/■ ■ //rd t!/ ■t ■on War an ■■■■■■■1 � are u�iii■■■nnoli,■/■t owa ■4a / 711/// ■ ■ ■ /1 it! /�rI ■ / ■ / / / /� ■tl' ■ ■ ■I � =- = = =Eh -m! M l ■ ■ ■ ■ ■ ■al fat? umum■■■i■mmr!immmi lion a wr7�gdmml 1! t J Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Love Stowed Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor /Base Sheet and Identify Manufacturer Attachment (If a component is not used, Identify as -NA") System Manufacturer. 1 /Field: oc @Lap. #Rows � @ oc NOA No.: NP-4, Design Wind Pressures, From RAS 128 or Calculations: Pmw1: _1_� Pmax2: gz ' (' PrratC3: Max Design Pressure, From the Specific NOA System: 5-21- Deck: Type: --'G" 1 0.6 � -0®!% - % 're Gaugelfhickness: Slope: �� �►! Anchor/Base SSh =eet& No. of Piy(s): AQ& Jr— Ak e Fastener on n erial: 9 y a Insulation Base Layer. Base Insulation Size and Thickness: ' Base Ins ation Fastener/Bonding Material: Perimeter _(a_� oc @ Lap, # Rows _ @ 4�L_^ oc Comer: -t"-- oc @ Lap, # Rows __:K"@ oc Number of Fasteners Per Insulation Board Field: -/ Perimeter ! Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Wicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 1 S. Top Insulation Layer; /� Top Insulation Size and Thickness- Top Irleulation FastenedBonding Material: p Base Sheet(s) & No. of pty(s) - 4111Z Base SRhjt Fastener/Bonding Material: 17 Pty Sheets) & No. of Piy(s): Pty S et Fast ing Material: Top Ply: (JN .1/ ri . J A Mean Roof COUNTY' MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175 -2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315 -2590 F (786) 31525 -99 NOTICE OF ACCEPTANCE (NOA) www.miamidade,m /ecoaomv GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GAF Ruberoie Modified Bitumen Roof System for Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09- 0224.01 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. APPROVED NOA No.: 13 -0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page I of 29 ROOFING SYSTEM APPROVAL Catesory Roofing Sub- Catmory: Modified Bitumen Material: APP /SBS Deck 11 e: Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED I TABLE 1 Test Product Dimensions Specification Matrix'" 102 SBS 5 gallons ASTM D3019 Membrane Adhesive )R LABELED BY APPLICANT: " Product Description Fiber reinforced rubberized cold - applied adhesive for modified bitumen roof systems. GAFGLAS® #75 39.37' ASTM D4601 Type II asphalt impregnated and coated Base Sheet (1 meter) Wide glass mat base sheet. GAFGLAS® #80 Ultima"' 39.37' ASTM D4601 Type II asphalt impregnated and coated, Base Sheet (1 meter) Wide fiberglass base sheet. GAFGLAS® F1exPly .. 6 39.37' ASTM D2178 Type VI asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS® Ply 4 39.37' ASTM D2178 Type IV asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS® Mineral 39.37' ASTM D3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet (1 meter) Wide surfaced with mineral granules. GAFGLAS® EnergyCapT" 39.37' ASTM D3909 Asphalt coated, glass fiber mat cap sheet BUR Mineral Surface Cap (1 meter) Wide surfaced with mineral granules with Sheet factory applied EnergyCotel' GAFGLAS® Stratavene 39.37' ASTM D4897 Fiberglass base sheet coated on both sides Eliminator" Perforated (1 meter) Wide with asphalt. Surfaced on the bottom side Venting Base Sheet with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS® Stratavene 39.37' ASTM D4897 A nailable, fiberglass base sheet coated on Eliminator' Perforated (1 meter) Wide both sides with asphalt. Surfaced on the Nailable Venting Base bottom side with mineral granules Sheet embedded in asphaltic coating. Ruberoid® SBS 39.37' ASTM D6164 Non -woven polyester mat coated with Heat - Weld's Smooth (1 meter) Wide polymer- modified asphalt and smooth surfaced. Ruberoid® SBS 39.37' ASTM D6164 Non -woven polyester mat coated with Heat - Weld" Granule (1 meter) Wide polymer- modified asphalt and surfaced with mineral granules. RoofMatchTm 107 sq. ft. ASTM D6164 Non -woven polyester mat coated with SBS Modified Granular (9.9 m2) SBS polymer- modified asphalt and surfaced with colored mineral granules. Ruberoid® SBS 39.37' ASTM D6164 Non -woven polyester mat coated with fire Heat - Weld` 170 FR (I meter) Wide retardant polymer- modified asphalt and surfaced with mineral granules. NOA No.: 13-0424.14 1fjUU DARE cout�rPtr Expiration Date: 11/06/14 o URW Approval Date: 10/31/13 Page 2 of 29 Test Product Product Dimensions Specification Descriotion Ruberoid® SBS 39.37" ASTM D6164 Non -woven polyester mat coated with Heat -Weld Plus (1 meter) Wide polymer - modified asphalt and surfaced with mineral granules. Ruberoid` SBS 39.37" ASTM D6164 Non -woven polyester mat coated with fire Heat -Weld Plus FR (I meter) Wide retardant polymer- modified asphalt and surfaced with mineral granules. Ruberoid' EnergyCap' 39.37" ASTM D6164 Non -woven polyester mat coated with fire SBS Heat- Wcl(f. Plus FR (1 meter) Wide retardant polymer- modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid® SBS 39.37' ASTM D6163 Non -woven polyester mat coated with Heat -Weld 25 (1 meter) Wide polymer - modified asphalt and smooth surfaced. Ruberoid® Mop Granule 39.37' ASTM D6164 Non -woven polyester mat coated with (1 meter) Wide polymer- modified asphalt and surfaced with mineral granules. Ruberoid Mop Smooth 39.37' ASTM D6164 Non -woven polyester mat coated with (1 meter) Wide polymer - modified asphalt and smooth surfaced. Ruberoid' Mop Plus 39.37' ASTM D6164 Non -woven polyester mat coated with (1 meter) Wide polymer- modified asphalt and surfaced with mineral granules. Ruberoid' Mop 170FR 39.37' ASTM D6164 Non -woven polyester mat coated with fire (1 meter) Wide retardant polymer modified asphalt and surfaced with mineral granules. Ruberoid Mop FR 39.37' ASTM D6164 Non -woven polyester mat coated with fire (1 meter) Wide retardant polymer- modified asphalt and surfaced with mineral granules. Ruberoid® Torch Smooth 39.37' ASTM D6222 Non -woven polyester mat coated with (1 meter) Wide APP modified asphalt and smooth surfaced. Ruberoid Torch Granule 39.37' ASTM D6222 Non -woven polyester mat coated with (1 meter) Wide APP modified asphalt and surfaced with mineral granules Ruberoie EnergyCap7 39.37' ASTM D6222 APP modified cap membrane with a torch Torch Granule FR (1 meter) Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote7. Ruberoido EnergyCap' 39.37' ASTM D6222 APP modified cap membrane with a torch Torch Granule Plus FR (I meter) Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCoteTm. RoofMatch'" 107 sq. ft. ASTM D6222 Non -woven polyester mat coated with APP Modified Granular (9.9 m2) APP polymer- modified asphalt and surfaced with colored mineral granules. Ruberoid® Torch FR I meter ASTM D6222 Non -woven polyester mat, coated with fire (39.37') Wide retardant asphalt modified bitumen membrane with granule surface. NOA No.: 13 -0424.14 MNMMI SAM CouNW Expiration Date: 11/06/14 • Approval Date: 10/31/13 Page 3 of 29 Test Product Dimensions Specification Ruberoie 20 1 meter ASTM D6163 (39.37 ") Wide Ruberoie 30 1 meter ASTM D6163 (39.37 ") Wide Ruberoie 30 FR 1 meter ASTM D6163 (39.37 ") Wide Ruberoie EnergyCap- 30 1 meter ASTM D6163 FR SBS Membrane (39.37 ") Wide Ruberoie Dual FR 39.37" (1 meter) ASTM D6162 Wide Topcoat Elastomeric Roofing Membrane Topcoat® MB Plus Topcoat Surface Seal SB FireOuC Fire Barrier Coating VersaShield® Fire - Resistant Roof Deck Protection 1, 5 or 55 gallons ASTM D6083 5 or 55 gallons Proprietary 5 gallons ASTM D6083 5, 55 gallons Proprietary 42" x 100' rolls ASTM D226 Product Description SBS modified asphalt base sheet reinforce with a glass fiber mat. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant, polymer- modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant, polymer - modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. An acrylic, water based eastomeric membrane system designed to protect various types of roofing surfaces. Water based, low VOC primer used to block asphalt bleed-through. Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. Low VOC, water -based fire barrier coating. Non - Asphaltic, fire resistant fiberglass - based underlayment. NOA No.: 13- 0424.14 Expiration Date: 11/06/14 Approval Date: 10131113 Page 4 of 29 APPROVED INSULATIONS: Product Name EnergyGuard7 Polyiso Insulation EnergyGuard7 RA Polyiso Insulation EnergyGuard7 RN Polyiso Insulation EnergyGuard7 Perlite Recover Board EnergyGuarC Perlite Roof Insulation EnergyGuard7 RA Composite Polyiso Insulation Carbon steel fastener used StructodeV High Density Fiber Board Securock'o Gypsum -Fiber Roof Board APPROVED FASTENERS: Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite roof board Polyisocyanurate /wood fiberboard or perlite composite High density wood fiber Gypsum board TABLE 3 Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF Blue Ridge FiberBoard, Inc. United States Gypsum Corp. Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill -TecT" #12 Fastener Carbon steel fastener used Various GAF in steel or wood decks. 2. Drill -TecT' #14 Fastener Carbon steel fastener used Various GAF in steel, wood or concrete decks. 3. Drill -Tec" XHD Fastener Carbon steel extra heavy Various GAF duty fastener used in steel decks. 4. Drill -TecT" AccuTrace Flat AZ -SS aluminized steel 3" x 3" GAF Plate plate for use with Drill - TecT" #12 Fastener, Drill - TecT" # 14 Fastener and Drill -TecT" #15 Fastener. 5. Drill -TecT" ASAP 3S Drill -TecT" #12 fastener Various GAF with Drill -TecT' 3" Standard Steel Plate. 6. Drill -TecT' AccuTrac® Galvalume Steel plate for 3" x 3" GAF Recessed Plate use with Drill -TecT` fasteners. 7. Drill -Tec' 3" Steel Plate Round galvalume steel 3" GAF stress plate for use with Drill -TecT' fasteners. 8. Drill -TecT' 3" Standard Round galvalume plated 3" GAF Steel Plate steel stress plate with reinforced ribs for use with Drill -TecT' fasteners. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 5 of 29 EVIDENCE SUBMITTED: Test Aaencv Test Identifier Description Date Factory Mutual Research Corp. 3029832 FMRC 4470 05/11/07 3010215 FMRC 4470 03/01/01 3001276 FMRC 4470 01/28/99 1139A8.AM FMRC 4470 09/04/97 3D4Q2.AM FMRC 4470 04/30/97 OD1A8.AM FMRC 4470 04/01/98 Underwriters Laboratories R1306 UL 790 07/22/13 Trinity Engineering 4483.04 97 -1 TAS 114 06/06/97 PRI Asphalt Technologies, Inc. GAF - 020 -02 -01 ASTM D249 02/01/02 ASTM D4977 GAF 306 -02 -01 ASTM E96 07/07/11 GAF 315 -02 -01 ASTM D2178 8/23/11 GAF 314 -02 -01 ASTM D2178 8/23/11 IRT -ARCON Inc. 02 -005 TAS 114 03/01/02 02 -014 TAS 114 04/08/02 01 -039 TAS 114 03/01/02 Trinity ERD G6850.08.08 ASTM D6164 08/29/08 G6850.08.08 ASTM D6163 08/01/08 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 11/05/08 G40620.07.12 -2 ASTM D6222 07/17/12 G34140.04.11 -2 ASTM D6163 04/25/11 G31360.03.10 ASTM D6164 03/31/10 G34140.04.11 -4 ASTM D4601 04/25/11 G34140.04.11 -5 ASTM D4897 04/25/11 G33470.01.11 ASTM D6164 01/13/11 G6850.08.07 -1 ASTM D3909 08/13/07 G30250.02.10 -3 -R1 ASTM D3909 11/26/12 PRI Construction Technologies LLC. ASTM D2178 GAF - 314 -02 -01 08/23/11 ASTM D2178 GAF - 315 -02 -01 08/23/11 ASTM D6083 GAF- 245 -02 -01 06/10/10 ASTM D6083 GAF -084-02 -01 07/08/05 ASTM D6083 GAF- 245 -02 -01 06/10/10 ASTM D6083 GAF -084-02 -01 07/08/05 Momentum Technologies, Inc. ASTM D6162 AX04C9A 06/05/09 NOA No.: 13- 0424.14 Expiration Date: 11/06/14 Approval Date: 10/31113 Page 6 of 29 Membrane Type: SBS /SBS Cold Applied " Deck Type 1: Wood, Non - insulated Deck Description: 19/32' or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOufm Fire Barrier Coating, VersaShieie Fire - Resistant Roof Deck (optional) Protection or Securock" Gypsum -Fiber Roof Board. Base sheet: GAFGLAS" #80 Ultima — Base Sheet, GAFGLAS" Stratavene Eliminator Nailable Venting Base Sheet, Ruberoid" 20, Ruberoid" SBS Heat - Weld' Smooth or Ruberoid" SBS Heat - Weld° 25 base sheet mechanically fastened to deck as described below: Fastening GAFGLAS" Ply 4, GAFGLAS" F1exPly"m 6, GAFGLAS" #75 Base Sheet or any Options: of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS" Ply 4, GAFGLAS" FlexPlyTM 6, GAFGLAS" #75 Base Sheet or any of above base sheets attached to deck with Drill-Tec7 #12 Fastener, Drill-Tec7 # 14 Fastener or Drill- TecT°" XHD Fastener and Drill -TecTm 3" Steel Plate, Drill - Tecra AccuTrac" Flat Plate or Drill -Tec" AccuTrac" Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation # i "'GAFGLAS" F1exPlym 6, GAFGLAS" #75 Base Sheet or any of above base sheets °'` attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. e, (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS" #80 Ultima"' Base Sheet, Ruberoid" 20, Ruberoid" Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation # i GAFGLAS" #75 Base Sheet or any of above base sheets attached to deck with Drill -Tecm #12 Fastener, Drill -Tec'M #14 Fastener or Drill -Tec7 XHD Fastener and Drill-TecTm 3" Steel Plate, Drill -TecT" AccuTrac" Flat Plate or Drill- Teo`°° AccuTrac" Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. ( Maximum Design Pressure —60 psf, See General Limitation #7) Any of above base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 25 of 29 GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec .- # 12 Fastener, Drill -TecT # 14 Fastener or Drill-TecT" XHD Fastener and Drill -TecTM 3" Steel Plate, Drill -TecT" AccuTrac* Flat Plate or Drill -Tec7 AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional) One or more plies GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6, GAFGLAS® #80 Ultima Base Sheet, Ruberoid® Mop Smooth or Ruberoid® 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Membrane: One or more plies of Ruberoid® Mop Smooth, Ruberoid Mop 170 FR, Ruberoid Mop Granule, RoofMatce SBS Modified Granular, Ruberoid® Mop Plus Granule, Ruberoid® 20, Ruberoid® 30, Ruberoid® EnergyCap7 30 FR SBS Membrane, Ruberoid® 30 FR or Ruberoid® Mop FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Or One or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop Granule, RoofMatch"4 SBS Modified Granular, Ruberoid® Mop 170 FR, Ruberoid® Mop Plus Granule, Ruberoid' 20, Ruberoid°° 30, Ruberoid® EnergyCap"30 FR SBS Membrane, Ruberoid® 30 FR or Ruberoid' Mop FR adhered in MatrixTM 102 SBS Membrane Adhesive at an application rate of 1 -2 gal. /sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 601bs. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTm BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 tbs./sq. 3. Topcoat® Elastomeric Roofing Membrane, Topcoat' MB Plus (to be used as a primer with Topcoat Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5 gal. /sq. Maximum Design Pressure: APPROVED See Fastening above NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31113 Page 26 of 29 Membrane Type: SBS /SBS Cold Applied Deck Type 1I: Wood, Insulated Deck Description: 19/3x' or greater plywood or wood plank System Type D(1): Insulation and Base sheet simultaneously attached All General and System Limitations shall apply. Fire Barrier: FireOut'" Fire Barrier Coating, VersaShieie Fire - Resistant Roof Deck (optional) Protection or Securock* Gypsum -Fiber Roof Board. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuard7 Polyiso Insulation, EnergyGuarC RA Polyiso Insulation, Structodek! High Density Fiber Board Minimum 1" thick N/A N/A Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAe #80 Ultima'' Base Sheet, GAFGLAS® Stratavene Eliminator Perforated Venting Base Sheet or Ruberoie 20 applied over the loose laid insulation with 2" side laps mechanically fastened to deck as described below; Fastening Options: Drill -Tec7 #12 Fastener, Drill -TecT" #14 Fastener or Drill -Tec7 XHD Fastener and Drill -Tec"" 3" Steel Plate, Drill-Tec'" AccuTrae Flat Plate or Drill-TecTm AccuTrace Recessed Plate installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS" #80 Ultimar" Base Sheet, Ruberoie 20, Ruberoie Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill -Tec"u #12 Fastener, Drill -Tec*'m #14 Fastener or Drill -TecTM XHD Fastener and Drill -Tec'" 3" Steel Plates in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill -TecTm #12 Fastener, Drill -TecTm #14 Fastener or Drill-Tec'" XHD Fastener and Drill -Td" 3" Steel Plate, Drill -Tec=" AccuTrace Flat Plate or Drill -Tec7 AccuTrae Recessed Plate installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) NOA No.: 13- 0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 21 of 29 Ply Sheet: (Optional) One or more plies GAFGLASe Ply 4, GAFGLASe F1exPlyTm 6, GAFGLASe #80 Ultimate' Base Sheet, Ruberoide Mop Smooth or Ruberoid® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Membrane: One or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, RoofMatch7 SBS Modified Granular, Ruberoid® Mop Plus Granule, Ruberoid® 20, Ruberoid' 30, Ruberoid EnergyCap" 30 FR SBS Membrane, Ruberoide 30 FR or Ruberoid® Mop FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Or One or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop Granule, RoofMatch7 SBS Modified Granular, Ruberoid® Mop 170 FR, Ruberoide Mop Plus Granule, Ruberoide 20, Ruberoide 30, Ruberoide EnergyCapT°' FR 30 SBS Membrane, Ruberoide 30 FR or Ruberoide Mop FR adhered in MatrixTM 102 SBS Membrane Adhesive at an application rate of 1 -2 gal. /sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 601bs. /sq. 2. GAFGLASe Mineral Surfaced Cap Sheet or GAFGLASe EnergyCapT' BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Topcoat® Elastomeric Roofing Membrane, Topcoat® MB Plus (to be used as a primer with Topcoat® Elastomeric Roofing Membrane) or Topcoate Surface Seal SB applied at 1 to 1.5 gal. /sq. Maximum Design Pressure: See Fastening above NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 1051113 Page 22 of 29 WOOD DECK SYSTEM LIMITATIONS: I A slip sheet is required with GAFGLAS" Ply 4 and GAFGLAS® FlexPly ' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4" DensDecO Roof Board or 1 /a" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMIITATIONS: I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 tbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall he limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter hailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13- 0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 29 of 29