Loading...
RF-13-2736Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number. INSP- 204016 Permit Number: RF -12 -13 -2736 Scheduled Inspection Date: February 14, 2014 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: TURKEL, DOUGLAS Work Classification: Repair Roof Job Address: 220 GRAND CONCOURSE Miami Shores, FL 33138- Phone Number Parcel Number 1132060133520 Project: <NONE> Contractor: QUALITY ROOFING CONTRACTORS INC L9S•]iilulall! -I INSTALL NEW PLUMBING STACK AND SEAL GABLE BY WALL FLASHING INSPECTOR COMMENTS False Phone: (305)953 -3333 February 13, 2014 For Inspections please call: (305)762 -4949 Page 16 of 33 Inspector Comments Passed Failed Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. February 13, 2014 For Inspections please call: (305)762 -4949 Page 16 of 33 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: JOB ADDRESS: BUILDING 220 Grand Concourse FBC 20 Permit No. Master Permit No. ROO INF G City: Miami Shores County: Miami Dade Zip: 3 31 3 8 Folio/Parcel #: 11-3206-013-3520 Is the Building Historically Designated: Yes NO X Flood Zone: OWNER: Name (Fee Simple Titleholder): Douglas Turkel Phone#: (3 0 5) 332-9494 City: 220 Grand Concourse Miami Shores Ste: Florida Tenant/Lessee Name: Phone#: Email: 33138 CONTRACTOR: CompanyNameQuality Roofing Contractor, Inc.phone#: ( 305) 953 -3333 Address: 13800 N.W. 1st Avenue City: Miami - Ste: Florida Zip: 33168 Qualifier Name: Carlos Arocho Phone#: ( 786) 367 -2029 State Certification or Registration #: RC 0 0 5 8 6 2 7 Certificate of Competency #: 0 0 0 017 8 8 9 Contactphone#: (305) 953 -3333 Email Address: qualityroofing88@yahoo.com DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ 5 0 0 . 0 0 Square/Linear Footage of Work: 1 /2sq,. Type of Work: ❑Addition ❑Alteration ❑New 02Repair/Replace ❑Demolition Description of Work ,Install new plumbing stack, and seal gable by wall flash ng . 00 Submittal Fee Scanning Fee $ Color thru file: Permit Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not die approved and a reinspection fee will be charged. SignatureJ Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of V1x, 20 L, by Lq0 0 �-L,1L day of , 20 , by „C la. � I� l� C.4-0 , who is personally kwown to me or who has produced who is person known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: APPROVED BY identification and who did take an oath. NOTARY PUBLIC: Sign: Print: MARYLOU HERNANDt3 MY MY COMMISSION # FF 059092 EXPIRES: October 10, 2017 WXW Thru Notary MUD Undemhers -/ (()// ;� Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06(10/2009)(Revised 3/15/09) MARYLW MYCOMMMION#FFORM EXPIRES. October 10, 2017 Bonded TMu Nay POW Undsrwrbm Zoning Clerk SECTION 2 mIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the.roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 44 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor .�owne�tra- tkdcon%tsoxisa s= ' � gas ern- e�cpTart° -red: ,4: AesthetJcs crkmanship: The workmanship provisions of Chapter 44, Section 44402 (High vei&cffy Hurricane Zone) are for the purpose of providing that the rooting system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not par: of a zoning code, should be addressed as part of the agreement between the owner and the co actor. '- Renalling Wood Decks: When replacing roofing, the existing wood roof deck may have to be renail din accordance with the current provisions of Section 84.403 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system.) Common Roofs: Common roofs are those which have no visible delineation between nefglhboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing co Za a6/,— or and/or owner should notify the occupants of adjacent units of roofing work to be performed. . Exposed Ceiiings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nai etrations of the underside of the decking may not be acceptable. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and peTbrmance of the new roofing system. Ponding conditions may not be evident un . the original roofing system is removed. Ponding conditions should be corrected. &d. overflow scuppers (wall outlets): it is required that rainwater flow off so that the roof is not oven ailed from a build up of water. Perimeter /edge wails or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in ac=dance with the Florida Building Code, Sections 4402, 4403 and W-�. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. qr' !Agent's Signature Cate Contractor's Signature Property Address Permit Number A 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES , , Job Address • LOW Slope • Asphaiiic Shingles Florida Building Code Eciifl ®n 2010 elocity hurricane Zone Uniform Permit Application ,Sactl ®n A (Genaral Information) P� ®�� ® Mortar /Adhesive Set Tile ® Wood Shingles/Shakes 15.34 2010 FLORIDA BUILDING CODE -- BUILDING ROOF ASSEL48LJES AND ROOFTOP STRUCTURES Florida Building Code Edidon 2010 P P ■ • • • i ■ • ■ • : e S o 0 P e ■ ■ a • v Roof System Manufacturer: Clay Forever Notice of Acceptance Number: 11 - 0 7 0 7.0 3 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations : 1: N/A P2:.-. N/A PS: N/A "�. �� • -_r •�.�•! it M17. ° ;- ,: ;�!� i�1.' �: {' +•; ;�' Deck Type: wood 1 X 6 Type Undertayment: 3 0.1 b. ASTM D-226 Roof Slope: 12 insulation: N/A Fir® Berner: N /p, Ridge Veen tattow Fastener Type & Spacing: 1 1 /4" R / S nails NI AdheslveType: 901b. ASTM/ PG500 MB Flash Type Cap Sheet: 901b. AST* 3' Roof Covering: Spanish S Clay Tile Mean Roo�Vft�- P Y Type & Size 3 X 3 2 6 a. Drip Edge: 15.36 2010 FLORIDA BUILDING CODE — BUILDING r MIAMI -DARE COUNTY PRODUCT CONTROL SECTION .BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www•miamidade my /t/uildine/ Clay Forever 6801 NW 77 Avenue, Suite 301 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AF.). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: tnsa �SCIayl�ooT�e LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. I-1` O— A No.: 11- 0707.03 "000W Expiration Date: 08/26/14 APPROVED: Approval Date: 10/13/11 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub- Cateaorv: Roofing Tiles Material: Clay Deck Tyne: Wood 1. SCOPE This new roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.U. in Pimienta, Honduras and distributed by Clay Forever LLC as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Altusa "S" Clay Length: 18 -3/4" High profile, one - piece, `S' shaped single roll Roof Tile Width: 10 -3/4" ASTM C 1167 clay the with a nominal 2 -' /a inch headlap. For varying thickness adhesive set applications. Trim Pieces Length: varies Accessory trim, clay roof pieces for use at Width: varies TAS 112 hips, rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. 2.1 SUBMITTED EVIDENCE: Test Aaencv Test Identifier Test Name/Report Date American Test Lab of South RT0426.01 -11 ASTM C 1167 05/07/11 Florida American Test Lab of South RT0706.01 -11 Static Uplift Testing 07/11/11 Florida TAS 101 IBA Consultants, Inc. 2397 -116 ASTM C 1167 06/28/07 The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied' 25- 7200 -1 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (Quick -Drive Screws, Battens) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC -78 TAS 100 Celotex Corporation Testing MTS 520649 TAS 102(A) May 2000 NOA No.: 11- 0707.03 pgppppE Cqy Expiration Date: 08/26/14 "' • Approval Date: 10/13/11 Page 2 of 9 ,1 I PRI Asphalt Technology, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. CLF- 003 -02 -01 7161 -03; Appendix III 7161 -03 Appendix H Letter Dated Aug. 1, 1994 P0631 -01 P0402 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations TAS 102 TAS 102 Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Aerodynamic Multiplier 25 -7183 25 -7094 25 -7496 25 -7584 25- 78b4b -8 25- 7804 -4 & 5 25- 7848 -6 October 2001 Dec. 1991 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 March 1999 March 1995 February 1996 April 1996 December 1996 3: LINUTATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with'TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 3.7 May be installed on slopes 7:12 and greater. APPROVED; NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 3 of 9 •l 4. INSTALLATION 4.1 Altusa "S" Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Altusa "S" Clay Roof Tile 6.5 1.56 0.9 Table 2: Aerodynamic Multipliers - X ft Tile Profile I (ft) Batten Application ;. (ft) Direct Deck Application Altusa "S" Clay Roof Tile 0.253 0.28 Table 3: Restoring Moments due to Gravi - M ft -lbf Tile Profile 3"• 12" or.less . 4 "• 12" 5" • 12" 6• 12" " 7 ": 12" or greater Altusa "S" Clay Roof Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Tile 4.47 5.35 4.40 5.27 4.31 1 5.16 4.2Q 5.03 4.08 4.89 NOA No.: 11- 0707.03 Expiration Date: OV26/14 APPROVEDi Approval Date: 10/13/11 Page 4 of 9 r� Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile Altusa "S" Clay (Min 15132" (Min. 19/32" Roof Tile plywood) plywood) Polyfbarn Product, Inc. Average weight per patty 8 grams. Altusa "S" 2 -10d Ring Shank Nails 28.6 41.2 19.4 Clay Roof Tile 1 -10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2 -10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1 .#8 Screw 28.7 28.7 18.1 248 Screws 58.2 58.2 26.8 1 -10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1 -10d Smooth or Screw 29.3 29.3 24.0 Shank Nail Eave Clip) 2 -10d Smooth or Screw 27.6 27.6 38.6 Shank Nails Field Clip) 2 -10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) 1 Screw with Altusa Clip See c ip details Altusa "S" 1 Screw with clip (at the 187.1 187.1 N/A Clay Roof Tile' head of tile) Altusa "S" 1 Screw with clip (at the 35.2 35.2 N/A Clay Roof Tile' water course of tile) 1. Screw must be installed in the inside nail hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft -lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Altusa "S" Clay Adhesive 29.3 Roof Tile 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 10.7 grams. Polyfbarn Product, Inc. Average weight per patty 8 grams. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 5 of 9 a Table 6: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Single Patty Adhesive Set Systems Tile Profile Tile. Tile Application Minimum Attachment Resistance Altusa °S" Clay Roof Tile Application Polyfoam Pol ProTm 66.5 Pol oam Pol ProTm 38,7 Pol oam Pol ProTm 52.05 4 La Me paddy placement of 63 rams of Pol PmTm. 5 Medium paddy placement of 24 rams of Pol Prow. 6 Large paddy placement-of 54grams of Pol PmTm. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Mortar Set Systems Tile. Tile Attachment Profile Application Resistance Altusa "S" Clay Roof Tile Mortar Set 24.50 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved ". ALTUSA MADE IN HONDURAS .LABEL FOR ALTUSA "S" CLAY ROOF TILE. (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 6 of 9 1C PROFILE DRAWINGS ""�y ALTUSA `S' CLAY ROOF TILE NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 7 of 9 CLIP DETAms TILE BY ALTUSA ; (TYP-) 2412° OVERLAP (COVERS PIN HOLE) CLIP WITH ONE (1) SCREW ATTACHED TO DECK /�\ CLIP PLACEMENT DETAIL jAPPROVED SCREW IN THE INSIDE HOLE NEAREST TO THE HUMP OF THE TILE NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 8 of 9 SCREW (HOLDS CLIP ONTO DECK) CLIP DETAILS (CON'T) TILE BY ALTUSA (TYP -) U CUP PLACEMENT DETAIL 21/2" OVERLAP (COVERS PIN HOLE) SCREW IN THE INSIDE NAIL HOLE NEAREST TO THE HUMP OF THE TILE END OF THIS ACCEPTANCE DECK 1 1/4" 13/4" 314" GALVANIZED METAL CUP 21/2" SCREW NOA No.: 11- 0707.03 Expiration Date: 08/26/14 Approval Date: 10/13/11 Page 9 of 9