Loading...
RF-12-1162Miami Shores Village ECEI ED Building Department JUL 17 111tJ 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 20 BUILDING Permit No. RF- 6 -12 -1162 PERMIT APPLICATION Master Permit No. Permit Type: BUILDING ROOFING JOBADDRESS: 10150 NE 2nd Avenue City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel #: 11- 3206 - 013 -1850 Is the Building Historically Designated: Yes NO % Flood Zone: OWNER: Name (Fee Simple Titleholder): Paul Jean - Baptiste Phone#: 786-441-9178 Address: 12585 NE Miami Court City: North Miami State: FL Zip:33161 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: A Perfect Seal Roofing Phone #:305- 477 -1554 Address: 7905 NW 66th Street City: Miami State: FL Zip: 33166 Qualifier Name: Ar 1 3rn Hernandez Phone #: 305-477-1554 State Certification or Registration #: CCC 13 2 6 4 3 3 Certificate of Competency #: ContactPhonq,# 305 -E477 -1554 Email Address :dbory@- Perfectsealroof.com DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $10 , 5 0 0.0 0 Square/Linear Footage of Work: 2 5 0 0 Type of Work: ❑Addition DAlteration ❑New MRepair/Replace ODemolition DescriptionofWork: revise system to Concrete Deck with 1/211 insulation, 2 Alv Submittal Fee $ Permit Fee $ Scanning Fee $ CCF $ CO /CC $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ TOTAL FEE NOW DUE $ .- _ lk Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT: ' Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500,,1hi applicant must promise in good faith that a copy of the notice of commencement and contraction ien law brochure will b� livered to the person whose property is subject to attachment. Also, a certified copy of the recorded noti of commencement most be posted at the job site for the first inspection which occurs seven (7) days after the building permit is ued. In the abWnce of such posted notice, the inspection will not be approved and a reinpection fee will be charged. Signature Z2: , �+'� Signature Owner -or Agent The fore ping instrument was acknowledged before me this day of , 20 &�- , by , who is persorfilly known to me or who has produced As identification and who did take an oath. NOTARY UBLIC: .0' -",kv DAIMARYSM C * MY COMMISSION # DD 859460 EXPIRES: March 27 2013 Sign: ' Npq o� �o�``OP BMW Thru Budget Notmy Smhas Print: b/9 i MA-(Z.�I aO2y My Commission Expires: L$�3 l Z2-7i-7-0 Q, APPROVED BY Contractor The foregoing instrument was acknowledged before me this day of 20 t , by who is p rso y known to me or who has produced as identification and who did take an oath. /���i'lans Examiner NOTARY UBLIQ of ; ; DAWRY GORY � * gyl #D0858+� EXPIRES' March 5013 Sign: : WdedTluuerdg Print: yBogy My Commission Expires: 63l,T If Z, Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10/07)(Revised 06110/20D9)(Revised 3/15/09) . High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor /Base Sheet and Identify Manufacturer Attachment (If a component is not used. identify as 'NA') System Manufacturer: 64F /1&%a NGA No.: © 0 ` 692?, OT Design Wind Pressures. From RAS 128 or Calculations: Pmaxi:56• % Pmax2:9S, 4 Pmax3 Z19. & Field: or a@ Lap, tt Rows @ ' oc Perimeter ' oc @ Lap, a Rows _ @ ' oc Comer: ' oc @ Lap. X Rows @ ' cc Number of Fasteners Per Insulation Board Max. Design Pressure. From the Specific NOA System: :P70 Field Perimeter Corner Deck: ` Type; Illustrate Components Noted and �Qi7l�'� =�' =� �..> Details as Applicable: Gaugefrhickness: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Slope: Strip, Base Flashing, Counter- Flashing, ing, Etc. Anchor/Base Sheet & No. of Ply(s):457j4b41 Pl' n@ - can Roof Height, Parapet Height, i CCGd -1' He shing, Component Material, Anchor /Base Sheet Fastener/Bonding Material: t IT kn stener Type, Fastener /y1 4ae do g ub , : anufacturers Details that o ly ,' RA 11 and Chapter 16. Insulation Base Layer. �"' � i Base Insulation Size and Thickness: r Base Insulation Fastener/Bonding Material: Top Insulation Layer• Top Insulation Size and Thickness: , Top Insulation Fastener/Bon ing Material: Lr Fig; M _<'C3P00/�L"T il�'� Base Sheet(s) & No. of Ply(s): Rr P/1, 1014 Bas,# Sheet Fa ener/Sonding Material: Ply Sheet(s) & No. of Ply(s): C7Ar li, Ply Sheet Fas ener/Sondin Mate 'Mate I Top Ply: 57,0 � OR SttEe-7-/ Top Ply Fasten r/ onding Material: Surfacing: 0 C'L:Urvz� Ffa N.rvC� s "o.(. +46rtm APrA HeD. �`t3ri`aF Fv45tir/til'7 � ; I %!c OMPcs;rr3 aX ,trot AAW Ovt� -K +�2.i nA�� carve �7E t RY's'i�. ,HOT rvi0PF�0 v �q� s � rbiGY'FFiD l., 'm Shores Vill, APPRO\, E'-.1 BY ZONING 5;_.. ' BLDG DE - T SUBJECT, FT. i y Parapet Heiaht FT. l&F Mean Roof Height r.y DATE TGFU.R1306 - Roofing Systems Page 2 of 25 The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2-in, minimum gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use of polystyrene insulation board between minimum 3A -in. thick perlite board and deck with rosin paper (perlite/rosin paper /polystyrene /perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuard RA" or "Tapered EnergyGuard RA" or "EnergyGuard Composite RA" may be substituted for any Atlas polyisocyanurate insulation in any of the following Classifications. Trumbull "Perna Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". "GAFGLAS #80 Premium Base Sheet" may be used in any of the following systems. "GAFGLAS Flex Ply 6" and "Tri -Ply Ultra- Flexible Ply 6" are suitable alternates to "GAFGLAS Ply 6 ". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "Fireshield MB" at 21h to 3- gal /100- ft2. Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid Mop" SBS products in any applicable Classification. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite /polyisocyanurate composite or perlite /urethane composite or wood fiber /polyisocyanurate composite or phenolic, any thickness. Ply Sheer — Three or more plies Type G1 or "GAFGLAS Ply 4" or "Tri -Ply Ply 4" or "GAFGLAS Ply 6" hot mopped. Surfacing: — Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite /polyisocyanurate composite or perlite/urethane composite or wood fiber /polyisocyanurate composite or phenolic, any thickness. ply Sheer — Three or more plies Type GI or "GAFGLAS Ply 4" or "Tri -Ply Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced Cap Sheet'. 3. Deck. NC - Incline: 2 Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite/urethane composite, wood fiber /polyisocyanurate composite, phenolic, 2 -1n. maximum. Ply Sheer — Two or more plies Type GI "GAFGLAS Ply 4" or "Tri -Ply Ply 4 ", "GAFGLAS Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced Cap Sheet ". 4. Deck: NC Incline: 1/2 Insulation: — One or two layers "Isotherm R ", any thickness, hot mopped. pty,.Shest: — Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. 5. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): — Red rosin paper, nailed to deck. Base Sheet: — One ply Type G2 "GAFGLAS #75 Base Sheet" or "Tri-Piy #75 Base Sheet" (may be nailed). Ply Sheet: — One or more plies Type G1 "GAFGLAS Ply 4" or "Tri-Ply Ply 4" or GAFGLAS Ply 6 ". Cap Sheer — One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "Tri-Ply Mineral Surfaced Cap Sheet ". 6. Deck. NC Incline: 3 Base Sheer — One ply Type G2 "GAFGLAS #75 Base Sheet" or "Tri-Ply #75 Base Sheet ". Ply Sheer — One or more plies Type GI "GAFGLAS Ply 4" or "Tri-Ply Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "Tri-Ply Mineral Surfaced Cap Sheet ". http: // database. ul. com legi- binIXYVI template lLISEXT /1FRAMElshowpage.html% me =TG.. MIAMI DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI DADE COUNTY, FLORIDA METRO -DARE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX(305)375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up -Roof System for Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration daze or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration daze may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 0 8-0221.04 and consists of pages 1 through 19. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 0&0922.04 Expiration Date: 11/06113 • • • • Approval Date: 05105110 Page 1 of 19 ROOFING SYSTEM APPROVAL Category Roofing Sub - Category: BUR Deck Type: Concrete Maximum Design Pressure -457.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Leak BusterTM 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. MatrixTM103 Cold Process Adhesive LeakBustefm 3, 5 gallons ASTM D3019 Refined asphalt blended with a mineral MatrixTM 204 Wet/Dry ASTM D3409 stabilizer and fibers. Permits adhesion to wet Roof Cement and dry surfaces. LeakBusterTM 3, 5 gallons ASTM D2824 Fibered aluminum coating. MaxrixTM 303 Premium Fibered Aluminum Roof Coaxing LeakBusterTM 5 gallons ASTM D2824, Non - fibered. Aluminum pigmented, asphalt MatrixTM 304 Non- Type 1 roof coating Fibered Aluminum Roof Coatings LeakBusterTM 5 gallons ASTM D1227 Surface coaxing for smooth surfaced roofs. MatrixTM 305 Fibered Asphalt Emulsion LeakBusterTM 5, 55 gallons ASTM D41 Asphalt concrete primer used to promote MaxrixTM 307 adhesion of asphalt in built -up roofing. Premium Asphalt Primer Leak Busteim ASTM D1653 Surface coating for smooth surfaced and MatrixTM 322 ASTM D12 mineral surfaced roofs. Elastomeric Roof ASTM FA70 Coating ASTM D6038 GAF Mineral Shield® 60 lb. & 100 lb ASTM D1863 Granules for surfacing of exposed asphalt, Granules bags cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. NOA No.: 0 8-0922.04 Expiration Date: 11/06/13 JAPPROVEDI Approval Date: 05 /05/10 Page 2 of 19 Md GAFGLAe STRATAVENT® Eliminator Perforated GAFGLAe Flashing 39.37' (1 meter) ASTM D3672 Wide ASTM D4897 various Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. NOA No.: 08- 0922.04 Expiration Date: 11/06/13 rnar�t n+ ouaartt Approval Date: 005/10 Page 3 of 19 Test Product Produd Dim_ ensions Specileeation �?1nti�n TOPCOAT® 5,55 gallons ASTM D412 Elastomeric roofing membrane FireShield MB, ASTM D21 FireShield SB ASTM D1475 ASTM E1644 TOPCOAT* Proprietary Surface coaxing for smooth surfaced and Ener$yCoteTM mineral surfaced roofs. Elastomeric Coating TOPCOAT® ASTM D412 Surface coating for smooth surfaced and Surface Seal SB ASTM BI 17 mineral surfaced roofs. ASTM C794 ASTM G21 FTMS141.6271 ASTM D21 ASTM D1475 ASTM E1644 GAF Built -Up 100 lb. cartons, ASTM D312, interply mopping and surfacing asphalt Roofing Asphalt bulk Tyler 11 IL III and TV GAFGLAS® #75 Base 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat Sheet Wide base sheet. GAFGLAe #80 39.37" (1 meter) ASTM D4601 Asphalt impregnated and coated, fiberglass Ultima"m Base Sheet Wide base sheet. GAFGLAS® 39.37" (1 meter) ASTM D2178 Type VI asphalt impregnated glass felt with F1exPlyTM 6 Wide asphalt coating. GAFGLAS® Ply 4 39.37" (1 meter) ASTM D2178 Type TV asphalt impregnated glass felt with Wide asphalt coating. GAFGLAS® Mineral 39.37" (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet Wide surfaced with mineral granules. GAFGLAS® 39.37" (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet EnergyUpTm BUR wide Energy starTM surfaced with mineral granules with factory Mineral Surface Cap Title 24 applied EnergyCoteru Sheet Compliant GAFGLAe STRATAVENT® Eliminator Perforated GAFGLAe Flashing 39.37' (1 meter) ASTM D3672 Wide ASTM D4897 various Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. NOA No.: 08- 0922.04 Expiration Date: 11/06/13 rnar�t n+ ouaartt Approval Date: 005/10 Page 3 of 19 RUBEROID' Torch 3937" (1 meter) ASTM D5147 Heavy duty, polyester reinforced, asphalt Smooth Wide modified bitumen membrane. RUBEROID® Torch 3937' (1 meter) ASTM D6222 Asphalt impregnated, coated felt, surfaced Granule Wide ASTM D5147 with mineral granules. RUBEROID® Torch 3937" (1 meter) ASTM D6222 Heavy duty, polyester reinforced, coated with FR Wide Test Product Product Dimensions Specification Description GAFGLAS® 39.37" (1 meter) ASTM D3672 Fiberglass base sheet coated on both sides STRATAVENT® Wide ASTM D4897 with asphalt. Surfaced on the bottom side Eliminator Nailable with mineral granules embedded in asphaltic RUBEROe Mop FR 39.37" (1 meter) ASTM D6164 coating. RUBEROID® MOP 39.37" (1 meter) ASTM D5147 Non -woven polyester mat coated with Smooth Wide ASTM D6298 polymer modified asphalt. Does not have a factory applied surfacing. RUBEROe 1 sq. roll ASTM D5147 Woven fiberglass mat coated with polymer ULTRACLAD® SBS 101 lb. modified asphalt and surfaced with aluminum, copper or stainless steel foil. RUBEROV 39.37" (1 meter) ASTM D4601 Premium glass fiber reinforced SBS - modified Modified Base Sheet Wide Type II, Type base sheet. G2 BUR RUBEROIDu Mop 39.37" (1 meter) ASTM D6222 Non -woven polyester mat coated with Granule Wide ASTM D5147 polymer modified asphalt and surfaced with mineral granules. RUBEROID' Torch 3937" (1 meter) ASTM D5147 Heavy duty, polyester reinforced, asphalt Smooth Wide modified bitumen membrane. RUBEROID® Torch 3937' (1 meter) ASTM D6222 Asphalt impregnated, coated felt, surfaced Granule Wide ASTM D5147 with mineral granules. RUBEROID® Torch 3937" (1 meter) ASTM D6222 Heavy duty, polyester reinforced, coated with FR Wide ASTM D5147 fire retardant asphalt modified bitumen membrane, granule surface. RUBEROID® Mop 39.3T'(1 meter) ASTM D6164 Non -woven polyester mat coated with Plus Wide ASTM D5147 polymer modified asphalt and surfaced with mineral granules. RUBEROe Mop FR 39.37" (1 meter) ASTM D6164 Non -woven polyester mat coated with fire - Wide ASTM D5147 retardant, polymer modified asphalt surfaced with mineral granules. RUBEROID® 20 39.37" (1 meter) Wide RUBEROID® 30 39.37" (1 meter) Wide RUBEROID® 30 FR 39.37" (1 meter) Wide ASTM D6163 ASTM D5147 ASTM D6163 ASTM D5147 ASTM D6163 ASTM D5147 SBS modified asphalt base sheet reinforce with a glass fiber mat. Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non woven fiberglass mat coated with fire retardant, polymer modified asphalt and surfaced with mineral granules. NOA No.: 08-0922.04 Expiration Date: 11/06/13 Approval Date: 05/05/10 Page 4 of 19 NOA No.: 08- 0922.04 Expiration Date: 11/06/13 Cur Approval Date: 05105110 Page 5 of 19 Test Product Product Dimensions Snecification Description RUBEROID® 39.37" (1 meter) ASTM D6163 Non woven fiberglass mat coated with fire EnergyCapTM SBS 30 Wide retardant, polymer modified asphalt and FR surfaced with mineral granules with factory applied EnergyCoteTM. RUBEROV Mop 39.37" (1 meter) ASTM D6164 Non -woven polyester mat coated with fire 170 FR Wide ASTM D5147 retardant polymer modified asphalt surfaced with mineral granules. Vent Stacks TAS 100(A) One way valve vent used to relieve built -up (metal and plastic) ASTM D1929 pressure within the roof system. GAF Vent ASTM D635 Stacks are available in metal or plastic. APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuardTm RA Polylso Polyisocyanurate foam insulation GAF Materials Corp. Insulation & EnergyGuardTm RN Polylso Insulation EnergyGuardTM Composite Polyisocyanurate foam insulation GAF Materials Corp. with high density fiberboard or Permalite perlite insulation. EnergyGuardTM Fiberboard Fiberboard insulation. GAF Materials Corp. EnergyGuardTM Polylso Polyisocyanurate foam insulation GAF Materials Corp. EnergyGuardTM Perlite Perlite insulation board. GAF Materials Corp. EnergyGuardTM Recover Board Perlite recover board GAF Materials Corp. Structodek® TD Flame Resistant High Density Wood Blue Ridge Fiberboard, Inc Fiber board. StructodeV Insulation board Blue Ridge Fiberboard, Inc SECUROW Gypsum board USG Dens Deck®, Dens Deck Prime®, Water resistant gypsum board G -P Gypsum Corp. Dens Deck DuraGuardTm APPROVED FASTENERS: TABLE 3 . Fastener Product Product Manufacturer Number Name Description Dimensions _ (With Current NOA) 1. N/A N/A N/A N/A NOA No.: 08- 0922.04 Expiration Date: 11/06/13 Cur Approval Date: 05105110 Page 5 of 19 APPROVED SURFACING /COATING OPTIONS: System Number TABLE 4 Application Surfacing is Optional on granular surfaced membranes but required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. 1. Gravel or slag applied at 400 lbsJsq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak Bustefm MatrixTm 103 Cold Process Adhesive applied at a rate of 3 galJsq. 2. Leak BusterTM MatrixTM 303 Premium Fbered Aluminum Roof Coating, at 1.5 galJsq. 3. Leak BusterTM MatrixTM 322, TOPCOAT® MB Plus, TOPCOAT® FireShield Elastomeric Roofing Membrane, applied at 1 to 1.5 galJsq. 4. TOPCOAT® EnergyCoteTM roof coating applied at 1 to 1.5 gal./sq. 5. TOPCOAT® Surface Seal, TOPCOAT® FireShieie SB Solvent based Elastomeric Roofing Membrane applied at 1 to 1.5 galJs4. 6. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. EVIDENCE SUBmam: Test Aaencv Test Identifier Description Date Factory Mutual Research Corp. FMRC 1996 Current Insulation 01.01.96 Attachment Requirements Factory Mutual Research Corp. J.I.2B8A4.AM 4470 07.02.97 J.I.3B9Q1.AM 01.08.98 J.I..ODOA8.AM 07.09.99 J.I.ODIA8.AM 4470 - TAS 114 07.29.94 J.I.OY9Q5AM 4470 - TAS 114 04.01.98 3017250 4470 05.05.04 3036980 4470 08.14.09 Trin4l ERD G6850.08.07 -1 ASTM D 3909 08.13.07 NOA No.: 08- 0922.04 Expiration Date: 11/06/13 Approval Date: 05105 110 Page 6 of 19 Deck Type 3I: Concrete Decks, insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(3): Insulation layer adhered with approved asphalt. All General and System Limitations shall apply. �ase morelayers of any of the following insulations. nsulation Layer EnergyGuardTM RN Polylso Insulation Minimum 2" thick Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density /fe N/A N/A Insulation Fasteners Fastener (Table 3) Density /fe er to Roof lnsulation Minimum %2" thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of base sheet. All insulation shall be adhered to the deck in fall mopping of approved asphalt within the EVT range and at a rate of 20-40 lbs/100 fly. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels used as a top layer shall be placed with the polyisocyannrate side facing down. Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS" #80 UltimaTM Base Sheet, GAFGLAS0 PLY 4, GAFGLAS" F1exPly""6, RUBEROID" Modified Base Sheet or RUBEROID® 20 directly to the insulated substrate. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Ply Sheet: One or more plies of GAFGLAS® Ply 4 or GAFGLAS® FlexPly"m 6 ply sheets adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Cap Sheet: (Optional) One ply of GAFGLAe Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM BUR Mineral Surface Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq. Surfacing: (Optional) Apply any surfacing/coating option listed in Table 4. Note: Chosen components mast be applied according to manufacturer's application instructions. Maximum Design Pressure: -322.5 psf (See General Limitation #9.) NOA No.: 08- 0922.04 Expiration Date: 11/06/13 Approval Date. 05 /05 /10 Page 9 of 19 . , 1. CONCRETE DECK SYSTEM IffimATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117; calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 ps£ 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 2751b£ insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically. referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 0840922.04 E Expiration Date: 111003 Approval Date: 05 /05/10 Page 19 of 19 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (30S) 762.4949 ING PERMIT APPLICATION Permit Type: JOB ADDRESS: WELDING nF City: Mliami Shores County: Folio/ParceW ( ` --5Z 13_ Is the Building Historically Designated: Yes JUN 2.5 2012 s FBC 20 Q Permit No. Master Permit No. ROOFING Zone: OWNER: Name (Fee Simple Titleholder)0) 1!'mi --410r-e�S Phone#: 13M 90 Address: Q-1.50 N6 2 QVf, G City: m k cro State: F C Zip: 43 1 ti Tenant/Lessee Name: Phone# Email: CONTRACTOR: Company Name: fkr ' r ( Srt�kA k t cr, Phone#: Address: City: Qualifier Name: ±j I 1 Vy 1 FIC, 4 -1 lL,4 IC Phone#: (z-5c-`�) `r / I— State Certification or Registration #: VP -1 '-�YZJ Certificate of Competency ~ az ress: Contact Phone# W g �—) ..: }iESIGNER AAFCliitect/Engineer. ; '''! Phone#: *p1pe q #.-Work for this Permit: $10-S b Square/Linear Footage of Work C Type of Work: ❑Addiition ❑Alteration L3 New epair/Replace ❑Demolition Descriution.of Work: ��D� -.... ��� °� 4 A� h I _ t"otn�'thru tile? Submittal Fee S150 W =erjWt Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ 46311 a Bonding Cpmpany's Name (if applicable) _ Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certifced copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is i sued In the absence of such posted notice, the inspection will not be approv and a reinspection fee will be charged Signature Signature Owner or Agent ontractor The fore oing instrument was acknowledged before me thh�iyysed- day of 20, by who is rsonally known t me or who has produced As identification and who did take an oath. NOTARY PUBLIC: My Commission APPROVED BY DAIMARY BORY Commission # DD 869460 My Commission Expires March 27, 2013 Commission # DD 889480 My Commission Expires March 27, 2013 The fo mg instrument was acknowledged before me this day of —�, 20 2; by /1 wh know me or who has produced Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) h :+- :'.Y BORY .,, n,��. P `�'� L �tittYa,now+1 k DD 869480 ' " My Commission Expires g n_:ar Mc;r-rh 27, 2013 3 v gay p v 3 * )480 0 °14 ires Zoning Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION FORM ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED OR THE VILLAGE MAY MAINTAIN A FILE WITH YOUR INFORMATION FOR A $30.00 FEE PER YEAR. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LIC CARD B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE (CERTIFICATE HOLDER TO BE MIAMI SHORES VILLAGE BLDG DEPT) D. v COPY OF WORKERS COMPENSATION (EITHER CERTIFICATE OR EXEMPTION) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT C. COPY OF LIABILITY INSURACE (CERTIFICATE HOLDER MUST BE MIAMI SHORES VILLAGE BLDG DEPT) D. COPY OF WORKER COMP INSURANCE (EITHER CERTIFICATE OR EXEMPTION, YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE HOLDER AS FOLLOW: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 COMPLETE CQKRACTOWS INFORMATION BUSINESS NAME: _ 1 f C- izacE CT L pop-Fi ASS BUSINESS ADDRESS: -�Cr0.57 &)o toto1 6T CITY M i jq jW i STATE -F L ZIP CODE 3311oLe, BUSINESS PHONE: (. 306 4:734554 FAX NUMBER ( CELL PHONE (_._,.._) QUALIFIER'S NAME: P eVyIV 444- fA)MJDC-z QUALIFIER'S LIC NUMBER: 000-132-&V-9-3 E -MAIL ADDRESS (IF APPLICABLE): AO r � Qf? f�Le �fe c --5 ea ( v-o� . to m CmaW on MW BY MLDV 1 RV NAM MLDV HERNANDEZ, ARLYN MICHELLE A PERFECT SEAL ROOFING INC 7905 NUT 66 ST MIAMI FL 33166 STATE OF �oA AC# 503-8 X15 f Congratulations! With this license you become one of the nearly one million =iR� Q► BIISSS Floridians licensed by the Department of Business and Professional Regulation 1GD3�uIC3IV Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. CCC1323� #39817 58.96 Every day we work to improve the way we do business in order to serve you better. 'gip^ For information about our services, please log onto www.myfloridalicense.com C� rF C G'i`(3R There you can find more information about our divisions and the regulations that B�! impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. �g C$3t'c ISII der t� psevie3one. oS Ch.489 gs Thank you for doing business in Florida, and congratulations on your new license! s+t�t�+ceet� `d�t�, AUix,�.T#�2po�asaoes9 DETACH HERE MIAMI*DADE COUNTY 2011 LOCAL BUSINESS TAX RECEIPT 2012 FIRST -CLASS TAX COLLECTOR MIAMI-DADE COUNTY - STATE OF FLORIDA U.S. POSTAGE 140 W. FLAGLER ST. EXPIRES SEPT. 30, 2012 PAID 1st FLOOR MUST BE DISPLAYED AT PLACE OF BUSINESS MIAMI, FL MIAMI' FL 33130 PURSUANT TO COUNTY CODE CHAPTER SA - ART. 9 & 10 PERMIT NO. 231 THIS IS NOT A BILL - DO NOT PAY 459681-4 RENEWAL BUSINESS NAME / LOCATION RECEIPT NO. 479898-0 A PERFECT SEAL ROOFING INC STATE* CCC1326433 7905 NW 66 ST 33166 UNIN DADE COUNTY OWNER A PERFECT SEAL ROOFING INC Sec. Type of Business WORKER /S — 196,SJP-ECIALTY BUILDING CONTRACTOR 1 ZOTMO LAWS Of THE COUNTY OR CITIES, NOR DO NOT FORWARD DOES IT EXEMPT THE HOLDER FROM MY OT PERMIT NER OR uCENSE A PERFECT SEAL ROOFING INC REQUIRED BY THIS IS ARLYN HERNANDEZ PRES TI ICA NOT A CERTIFICATION A- THE HOLDER'S QUALIFlCA- 7905 NW 66 ST TINS. MIAMI FL 33166 PAYMENT RECEIVED MIAMMDADE COUNTY TAX COLLECTOR: 09/21/2011 60020000271 000075.00 iI 1111 tolls III VIII III III I lilt 111I111IIIIII1.Ill .111.IM41 SEE OTHER SIDE A kl. 6 , Rl' jumm f CERTIFICATE OF LIABILITY INSURANCE uno/12 wy"yj i 02127 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CZiFFE_F& NO RIQ4TS UPON THE CERTIFICATE HOLDER TH-19 IFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES S&ow. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. NPORTANT. If the C00111110" IwMai Is an ADDITIONAL MURED, the poficy(lu) must bo andomoot If SUBROGATION IS WAIVED, subject to on terms end midwon of do pocky. wtft poucift may mqwm an endorsement. A StMMOM on this mWicift don not confer rWft to *9 Gordticato hoklor In Neu of such ondoroomonU4 pRomtm Fast Class Insurance Insurance Market PMOM (305)441-2997 (305)441 -6443 t 392 Mhwca Ave. AV .. Coral Gables. FL 33134 INGUMKII) AFPGRW4G COV1111141AGE d Phone C30 "1-2997 Fax (30)441-6443 INSURER A: CATLIN INSURANCE COMPANY MOWED ASCENDANT INSIRANCE COMPANY A PERFECT SEAL ROOFING INC IAML c: 7605 NW 66 STREET DmRwt 0: MIAMI, FL 33142 COVERAGES CERTIFICATE NUMBER.' REVISION NUMBER:* THIS IS To CERTIFY THAT THE POLICIES OF WSURANCE LISTED BELOW HAVE BEEN ISSUED T07;6CiSLIRED KAIIAWA86W FOR THE POLICY PERIOD INDICTED. NOTWITHSTANDING ANY REQUIRIDENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES Lwrs SHOWN MAY HAVE SM REDUCED BY PAID CLAM. Wy LIMITS Lyn 'M POLICY A r I GENERAL LIABIL17Y EACH OC % fflimp—Mm - - - $ 50,000.00 $ 1,000,000-00 DAMAGE COMMERCIAL GENEIRIAL LLAMUTY P-Pi MIFAMA trio pw IA S 0.00 A =AIMS-MADE 0 o=fit 01214810 12/1&2011 12119=12 000-00 PERSONAL & MW INJURY 8 1.0W, GENERAL. AGGREGATE 5 2'000.000.00 GM AGGREGATE LIMIT AN LIES PM 1 3 oucy 0 P -LIMIT -ap AL WOOD= SINAL E AUTOMOSM LIABILfrT r-1 ANYAUTO C:] barNED r_1 PUREDAUTOS ❑ 08" - _ I C-1 - I . r-1 WADRELLA LIAR Lioc="oto I p 11110111311 LYiB LJ CLANS411ADE I -RETTEIM AND EMPLOMW UABILM YIN: AW PDROMPMRIMPETO WC61740-W 0=5=12 102aM13 B 6*42®RANIENMW NIA (MOWN" In NN) it douraw wvw bet" 11 ME! oESCWM=oF OPERATION I LOCATIONS IVgN=M gAuoAC=iv1.Add*onW Remarks fthmftd0 ffMM apace i$f"u0$Q CERTIFICATE .HOLDER . MIAMI SHORES VILLAGE BUILDING DEPARTMENT 10050 NE 2" AVENUE MIAMI SHORES, FL 33138 Bormy INAJRY (pw POMM) 80DILY INJURY (Pw a=419" AG>aReG�m E.L. EACH ACCIDENT S 1.000,000.00 E.L...OWASE - K.�.LZY LIMM! 9 1,000,000-00 . . —CANC.ELLATION. . ...... SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACGOL40AACE WITH THE POLICY PROVISIONS. o,i9w2oio ACORD CORPORATION. All rights reserved. ACORD 25 (20iWK CF J The ACORD name and lop are registered marks of ACORD NOTICE OF COMMENCEMENT A RECORDED COPY MW BE POSTED ON THE JOB SITE ATTHE OF Fi W MSPECTION PERMIT NO. TAXFOUONO.'t 7 -3 - 06 -t11 3 -T 850 STATE OF FLORIDA: COUNTY OF MIAMI -DARE: TIE UNDERSIGNED hereby gives notice that impromtentarwili be made to Cart* real property, and In accordarce with (bapter 713, Florida Statutes, the fobvirg information Is provided In this Notice of Commencement. 1111111 !fill dill 111111111111111111111111111 OR Bk 28160 Ps 2030; (lag) RECORDED 06 /22/2012 11:2038 HARVEY RUVINP CLERK OF COURT "IA"I -DARE COUNTY, FLORIDA LAST PAGE 1. Legal description of property and streetladdress: Miami Shores Sec 1 AM PB 10-70 lots 1 -5 -Blk 14 or 10150 NE 2nd Avenue Miami Shores FL 33138 2. Description of Improvement re -roof flat roof section only 3 Owners }name and address: Miami Shores Christian Church, Inc. 10150 NE 2nd Avenue Miami Shores FL 33138 Interest in property: owner Name and address of fee simple titleholder. 4. Contractor's name and address: A Perfect Seal Roofinnq (305) 477 -1554 7905 NW 66th Street Miami FL 33166 & Surety: (Payment bond required by owner from contractor, If any} Name and address: Amount of bond $ 6. Lender's name and address: ?. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1 xa)?'. , Florida Statutes, Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes .Name and address: a.' Expiration. dW of 'this NWce of Commencement: (the exphratiof Sato W1 yedr from .the date of recording f� natur ®.of Owner ►�V• � a Print Owner's Name � -hi � ��� �-- omt�, t_o�n Z it I day f !- 20 t9 Nay PubBa �4 This imslrume d ores by Y�-... .. .. d ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edit High - Velocity Hurricane Zone Uniform Permit M!arni Shores Village APPRObED I BY ZONING DEP,r SSU13JECT i0 CCMPLIANCE WITH ALL FEDERAL a 3� S17ifE AND =Wilf ARLES AND REGULAMONS Master Permit No. Process No. Contractor's Name A Perfect Seal Roofing Job Address 10150 NE 2nd A-venue Miami Shores FL 33138 ROOF CAT-EGORY ® Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles IN Prescriptive BUR -RAS 150 ROOF TYPE FLORIDA BUILDING CODE — BUILDING High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components and Identify Manufacturer (If a component is not used. identify as 'NA') System Manufacturer. CA/ NOA No.: V 7 1.2 d c9 Design Wind Pressures. From RAS 128 or Calculations: Pmax1: 40er•Z Pmax2: e°?• & Pmax3: /2q' 3 Max. Design Pressure From the Specific NOA System: Deck: i / wood Type: ., Gaugefrhickness: 513 Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation Fastener1Bonding Material: Top insulation Layer._ Top Insulation Sae and Thickness: Top insulation Fastener/Bonding Material: Fastener Spacing for Anchor /Base Sheet Attachment G Field: / ' oc @ Lap. ft Rows 4Z ,@ oc Perimeter. ' oc @ Lap, 9 Rows / ? @ � � oc Comer. _' oc @ Lap, tl Rows (P @ Al- oc Base Sheet(s) & No. of Pty(s): Off % l3ci / l'I Base Sheet FastenerBonding Material: Ply Sheet(s) & No. of Ply(s): Pty Sheet FastenerBonding Material: Top ply E7f1 i✓ity Vic' % Top Ply Fastener/ Bonding Bonding Material Material: 67-74 Surfacing:' Ga /Il %��`. i'!u �'`.rc,yGl•L 1= (!��� Number of Fasteners Per Insulation Board _ Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking. Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. FT. Parapet Height .I 17, wand . Mean Roof Height GAF Fl, w , 2 ?1 5 ve'rv' pi,» ,eel C),-? ,a p . —�. el ae. 12" n1o"y zd t" f . 601E CAP- 6weri. Section C2 MIAMI -MADE Miami -Dade County HVHZ Electronic Roof Permit Form s "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 15 HVHZ, FBC. Parapet Wall Height Mean Roof Height ( 0 ft. �F/3" 6 P 11 ,4wOCCA - +VAC- u4A.)1'C.4 LLq r+ eD 2 (:74W FL4 151, Z PLY flidl -f�r� Fk1Jr'A3.. PPZiMC® ON -ro p s . - 677 C W srfEE i . HOT mbppso . TGFU.R1306 - Roofing Systems Page 2 of 25 The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2-in. minimum gypsum board is an acceptable alternate for insulation over C-15/32 decks. The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite /rosin paper / polystyrene /perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuard RA" or "Tapered EnergyGuard RA" or "EnergyGuard Composite RA" may be substituted for any Atlas polyisocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". "GAFGLAS #80 Premium Base Sheet" may be used in any of the following systems. "GAFGLAS Flex Ply 6" and "Tri -Ply Ultra - Flexible Ply 6" are suitable alternates to "GAFGLAS Ply 6 ". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "Fireshield MB" at 21h to 3- gal /100- ft2. Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid Heat weld" SBS roofing membrane may be used in lieu of "Ruberoid Mop" SBS products in any applicable Classification. Class A 1, peck: C -15/32 Incline: 3 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite / polyisocyanurate composite or perlite /urethane composite or wood fiber / polyisocyanurate composite or phenolic, any thickness. ply Sheet: — Three or more plies Type Gl or "GAFGLAS Ply 4" or "Tri -Ply Ply 4" or "GAFGLAS Ply 6" hot mopped. Surfacing: — Gravel. 2. peck: C -15/32 Incline: 2 Insulation (Optional): — One or more layers periite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate omre site Typerlite/urethane "GAFGLAS PIy�4 "to �"Tii-Ply fPlyy 4" ory "GAFGLAS Ply composite or phenolic, any thickness. ply Sheet: — Cap Sheet: —One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or'"fri-Ply Mineral Surfaced Cap Sheet'. 3. Deck: NC Incline: 2 Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite /polyisocyanu rate composite, perlite /urethane composite, wood fiber / polyisocyanurate composite, phenolic, 2 -in. maximum. ply Sheet — Two or more plies Type G1 "GAFGLAS Ply 4" or "Tri -Ply Ply 4 ", "GAFGLAS Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or'Tri -Ply Mineral Surfaced Cap Sheet ". Incline: 1/2 4. Deck: NC Insulation. Ann UL Classified gravelsurfa surfaced Class A asphalt glass fiber system. ply Sheet: — Y S. Deck. C -15/32 Incline: i Slip Sheet (Optional): — Red rosin paper, nailed to deck. 5 — One ply Type G2 "GAFGLAS #7 t: Base Sheet" or "Tri-Ply #75 Base Sheet" may be nailed). Base Sheet: — ply Sheet: — One or more plies Type G1 "GAFGLAS Ply 4" or "Tn Ply Ply 4" or GAFGLAS Ply 6 ". Cap Sheet. — One ply Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "Tri-Ply Mineral Surfaced Cap Sheet ". Incline: 3 6. Deck: NC Base Sheep O eno Type G2 -GAFGLAS #75 Base Ply 4eeor "Tri PIy Ply 4" or"GAFGLAS Ply 6 ". ply Sheet: Cap Sheer. "GAFGLAS Mineral Surfaced Cap Sheet" or " Tn -Ply Mineral Surfaced Cap Sheet ". Sheer. — One PIY Type http -.I/ database. ul. com lcgi- binIXYVItemplatelLISEXT /1 FRAMElshowpage.html ?name =TG... 4/8/2009 r�oAnE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of page 1 thro gh 19. The submitted documentation was reviewed by Jorge L. Acebo. n NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 1 of 19 RooFING SYSTEM APPROVAL Cateaorv: Roofing Sub- Catenory BUR Deck Type: Wood Maximum Design Pressure -75 psf TRADE NAMES OF PRODUCTS MANUFACTUREI TABLE 1 Test Product pimensions Specification Leak BusterTm MatrixTM 3, 5, 55 gallons ASTM D 41 307 Premium Asphalt Piimer 1 OR LABELED BY APPLICANT: Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. GAF Mineral ShieldTM 60 & 100 lb. bags ASTM D 1863 Granules for surfacing of exposed asphalt, Granules cold process cement or emulsion. GAF Mineral ShieldTm Granules shall be used for flashing applications only. Leak BusterTm MatrixTm 5 gallons ASTM 1227 Surface coating for smooth surfaced roofs. 305 Fibered Asphalt Emulsion Leak BusterTm MatrixTm 1, 5 gallons ASTM D 2824 Fibered aluminum coating. 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTm 55 gallons Elastomeric roof coating. 322 Elastomeric Roof Coating LeakBusterTm Matrix:m 55 gallons Asphalt emulsion Fbered. Select Asphalt Emulsion Fibered 306 Leak Bustefm MatrixTM 1, 5 gallons ASTM D -4586 Refined asphalt blended with a mineral 204 Wet/Dry Roof ASTM D -3409 stabilizer and fibers. Permits adhesion to Cement wet and dry surfaces. RUBEROID® Modified 5 gallons ASTM D 4586 Fiber reinforced, polymer modified Flashing Bitumen Flashing cement Cement LeakBusterTM MatrixTM 5 gallons ASTM D 4586 Asphalt flashing Cement 201 Premium SBS Flashing Cement GAFGLAS® #75 39.37" ( 1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 GAFGLAS* STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT* Eliminatofrm Nailable RUBEROID® SBS Heat WeldTM Smooth RUBEROID® SBS Heat- WeldTM Granule RUBEROID® SBS Heat- WeldTM 170 FR RUBEROID® SBS Heat WeldTM PLUS RUBEROID® SBS Heat- Weld'rm PLUS FR RUBEROID® SBS Heat- WeldTM 25 39.37" (1 meter) ASTM D 4897 wide D 3672 Various 39.37" (1 meter) ASTM D 4897 wide D 3672 1 meter (39.37') ASTM D-6164 wide 1 meter (39.37") ASTM D -6164 wide 1 meter (39.37 ") ASTM D -6164 wide 1 meter (39.3T') ASTM D -6164 wide 1 meter (39.3T') ASTM D -6164 wide 1 meter (39.3T') ASTM D-6164 wide RUBEROID® Modified 39.37" (1 meter) ASTM D4601, Base Sheet wide Type 11, UL Type G2 BUR �APPROVEDj Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non - Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07- 1219.09 Expiration Date: 11104113 Approval Date: 03/20/08 Page 3 of 19 Test Product Product Dimensions Specification Description GAFGLA90 #80 39.37" (1 meter) ASTM D4601 Asphalt impregnated and coated, fiberglass ULTIMATM Base Sheet wide base sheet GAFGLAS'* 39.37" (1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt with Flex P1yTM 6 wide asphalt coating. GAFGLAe Ply 4 3937" (l meter) ASTM D 2178 Type IV asphalt impregnated glass felt with wide asphalt coating. GAFGLAS® Mineral 39.37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet wide surfaced with mineral granules. GAFGLAS" 39.3T'(1 meter) ASTM D 3909 Asphalt coated, glass fiber max cap sheet EnergyCapTM Mineral wide surfaced with mineral granules with factory Surfaced Cap Sheet applied layer of TOPCOATMEnergyCoteTM. GAFGLAS* STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT* Eliminatofrm Nailable RUBEROID® SBS Heat WeldTM Smooth RUBEROID® SBS Heat- WeldTM Granule RUBEROID® SBS Heat- WeldTM 170 FR RUBEROID® SBS Heat WeldTM PLUS RUBEROID® SBS Heat- Weld'rm PLUS FR RUBEROID® SBS Heat- WeldTM 25 39.37" (1 meter) ASTM D 4897 wide D 3672 Various 39.37" (1 meter) ASTM D 4897 wide D 3672 1 meter (39.37') ASTM D-6164 wide 1 meter (39.37") ASTM D -6164 wide 1 meter (39.37 ") ASTM D -6164 wide 1 meter (39.3T') ASTM D -6164 wide 1 meter (39.3T') ASTM D -6164 wide 1 meter (39.3T') ASTM D-6164 wide RUBEROID® Modified 39.37" (1 meter) ASTM D4601, Base Sheet wide Type 11, UL Type G2 BUR �APPROVEDj Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non - Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07- 1219.09 Expiration Date: 11104113 Approval Date: 03/20/08 Page 3 of 19 Test Product Product Dlmensions Snecil'ication Doserigtftn RUBEROID® 20 39.37" (1 meter) ASTM D 6163 SBS modified asphalt base sheet and wide ASTM D 5147 interply sheet reinforce with a glass fiber RUBEROID® Mop 39.37" (1 meter) mat. ASTM D 6222 Non -woven polyester mat coated with Granule wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. RUBEROID® Mop Plus 39.3P'(1 meter) ASTM D 6222 Non -woven polyester mat coated with (Granule) wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. RUBEROID® MOP 39.37" (1 meter) ASTM D 6164 Non -woven polyester mat coated with Smooth wide ASTM D 5147 polymer - modified asphalt and smooth surfaced. RUBEROID® MOP 39.37" (1 meter) ASTM D 6164 Non -Woven polyester mat coated with fire 170FR wide ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® MOP FR 39.37" (1 meter) ASTM D 6164 Non -Woven polyester mat coated with fire wide ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® TORCH 39.37" (1 meter) ASTM D 5147 Heavy duty, polyester reinforced, asphalt Smooth wide modified bitumen membrane, smooth surface. RUBEROIDO TORCH 39.37' (l meter) ASTM D 5147 Asphalt impregnated, coated felt, surfaced Granule wide with mineral granule. RUBER0I6M TORCH 39.3T' (I meter) ASTM D 6222 Heavy duty, polyester reinforced, asphalt PLUS (Granule) wide ASTM D 5147 modified bitumen membrane, granule surface. RUBEROID°s TORCH 39.37" (l meter) ASTM D 6222 Heavy duty, polyester reinforced, coated FR wide ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule surface. RUBEROIDO 170FR 39.3 T' (1 meter) ASTM D 6222 Heavy duty, polyester reinforced, coated TORCH Wide ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule surface. RUBEROIDs' 30 39.37' (1 meter) ASTM D 6163 Non -woven fiberglass mat coated with wide ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. RUBEROID® 30 FR 39.37" (1 meter) ASTM D 6163 Non -woven fiberglass mat coated with fire wide ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® 39.37"'(1 meter) ASTM D 6298 Woven fiberglass mat coated with Polymer ULTRACLADO wide ASTM D 5147 modified asphalt and surfaced with aluminum, copper or stainless steel foil. RUBEROIDP Dual FR 39.37" (1 meter) ASTM D 6164 Non -woven polyester and fiberglass mat Wide ASTM D 5147 coated with file retardant, polymer modified asphalt and surfaced with mineral granules. Vent Stacks (metal and TAS 100(A) One way valve vent used to relieve built-up plastic) ASTM D 1929 pressure within the roof system. GAF Vent ASTM D 635 Stacks are available in metal or plastic. NOA No.: 07- 1219.09 �' Expiration Date: 11/04/13 . • Approval Date: 03488 Page 4 of 19 Cement Leak BusterTm MatrixTm 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 102 SBS Adhesive Adhesive. Leak BusWTm MatrixTM 5 gallons ASTM Cold Applied Modified SEBS Asphalt 202 SBS Flashing Adhesive — Flashing Grade. Cement Leak Busteim MatrixTm 5 gallons ASTM D4586 Standard Plastic Asphalt Roofmg Cement 203 Plastic Roof Cement Leak BusterTM MatrixTm 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Bate: 03120/08 pages of 19 Test Product Product Dimensions Specification Description Leak Bustafm MatrixTM 5 gallons ASTM D2824, Non - fibered aluminum pigmented, asphalt 302 Non Fbbered Type I roof coating. Aluminum Roof Coating OAF Built -Up Roofing 100 lb. cartons, ASTM D312, Interply mopping and surfacing asphalt. Asphalt bulk Types I, II, ID and IV RUBEROID® MOD 60 lb. kegs SEBS modified asphalt. Asphalt, Asphalt L & Asphalt P Leak BusterTM MatrixTm 5 gallons Surface coating for smooth surfaced and 602 mineral surfaced roofs. Leak BusterTm MatrixTm 5 gallons Surface coating for smooth surfaced and 715 mineral surfaced roofs. LeakBusteem MatrixTM 2 gallons Surface coating for smooth surfaced and 531 WeatherCoteTM mineral surfaced roofs. SeamCOWN 2, 5 gallons proprietary Elastomeric roofing membrane. . FireOutrm 5, 55 gallons Low VOC, fire barrier coating. VersaShiele 350 sq ft. roll Non - Asphaltic Fiberglass -Based Underlayment. VersaShieldo FB-1S 350 sq ft. roll Non - Asphaltic Fiberglass -Based Underlayment. VersaShiele FB-2S 350 sq ft. roll Non- Asphaltic Fiberglass -Based Underlayment. TOPCOAT' FireShiele 5, 55 gallons ASTM D -412 Elastomeric roofing membrane MB ASTM D -21 -96 ASTM D1475 ASTM E -1644 Leak Busterrm MatrixTM 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 201 SBS Flashing Adhesive — Flashing Grade. Cement Leak BusterTm MatrixTm 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 102 SBS Adhesive Adhesive. Leak BusWTm MatrixTM 5 gallons ASTM Cold Applied Modified SEBS Asphalt 202 SBS Flashing Adhesive — Flashing Grade. Cement Leak Busteim MatrixTm 5 gallons ASTM D4586 Standard Plastic Asphalt Roofmg Cement 203 Plastic Roof Cement Leak BusterTM MatrixTm 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Bate: 03120/08 pages of 19 Test Product Product Dimensions Suecification Description Leak BusterTM MatriiTM 303 Fibered Aluminum Roof Coating Leak BusterTM MatrixTM 304 Non Fibered Aluminum Roof Coating 5 gallons ASTM D 2824 Fibered aluminum coating. 5 gallons ASTM D2824, Non - fibered aluminum pigmented, asphalt Type I roof.coating. APPROVED INSULATIONS: Product Name EnergyGuardTM RA, RN Composite A & N EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANTTM EnergyGuardTM Permalite Recover Board Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Manufacturer (With Current NOA) BMCA GAF Materials Corp. GAF Materials Corp. GAR Materials Corp. GAF Materials Corp. GAF Materials Corp. EnergyGuardTM Tapered Edge Strip Tapered perlite board GAF Materials Corp. EnergyGuardTM Perlite Perlite insulation board GAF Materials Corp. EnergyGuardTM High Density High density wood fiberboard insulation. GAR Materials Corp. Fiberboard EnergyGuardTM Composite EnergyGuardTM Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck *, Dens Deck® Prime, Dens Deck® Dura GuardTM Structodek SecurockTM Polyisocyanurate/wood fiberboard composite Polyisocyanumte/wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board BMCA BMCA generic generic generic G -P Gypsum Corp Knight Celotex USG Corporation NOA No.: 07- 1219.09 Expiration Date: 11/44!13 Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: Test Identifier Description Date- Factory Mutual Research Corp. J1.2B8A4.AM TABLE 3 07.02.97 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill -TecTm #12 Standard, Insulation fastener and Various GAF Materials Corp. # 14 and # 15 extra Heavy Base Play fastener for 05.11.07 PRI Asphalt Technologies, Inc. GAF -012 -02 -02 Duty Fastener, Heavy steel, wood & concrete GAF - 020 -02 -01 ASTM D 4977 Duty Roofing Fastener decks. 02 -005 T A S 1 l 4 2. Drill -TecTm ASAP Pre-assembled Drill- Various GAF Materials Corp. TecTM Fasteners and metal and plastic plates. 3. Drill -TecTM #12 or #14 Base sheet fastening Various GAF Materials Corp. Standard screws with assembly. AccuTrac Plate 4. Drip -Ted m Galvalume Round Galvalume stress 3" and 3 W GAF Materials Corp. Plates plates. 5. Drill -TecTM Round polypropylene 3" and 3 Aof GAF Materials Corp. Polypropylene Plates stress plates. 6. Drill -TecTM AccuTrac Square Galvalume® 3" Square GAF Materials Corp. Plate coated steel plate. EVIDENCE SUBMEMD: Test Agency Test Identifier Description Date- Factory Mutual Research Corp. J1.2B8A4.AM 4470 07.02.97 J.I.3B9Q1.AM 4470 01.08.98 J.I.ODOA8.AM 4470 07.09.99 Ll, ODiA&AM 4470 - TAS 114 07.29.94 J.I.OY9Q5.AM 4470 - TAS 114 04.01.98 3029832 4470 - TAS 114 05.11.07 PRI Asphalt Technologies, Inc. GAF -012 -02 -02 Physical Properties 11.06.01 GAF - 020 -02 -01 ASTM D 4977 02.01 A2 IRT of S. Fl. 02 -005 T A S 1 l 4 01.18.02 02 -014 TAS 114 03.22.02 NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 7 of I9 Deck Type 1: Wood, Non - insulated Deck Description: or greater plywood or wood plank decks 32 System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShiele Non-Asphaltic Fiberglass -Based (optional) Underlayment or Securockm. Baste sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® Eliminatofrm Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBER011)P Heat- WeldTM Smooth or RUBEROMP Heat- WeldTM 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS" Flex Plym 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAe Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -Tedm steel plate or Drill -Teem AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS1e Flex Plym AFGLAS® #75 Ba Sheet or any of above Base sheets attached to deck wi ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design P ure --52.5 psf, See eneral Limitation #7) GAFGLASO #80ULT1MA ® 20, RUBEROIDe1 Mop Smooth, base sheet attached to deck with approved 1 YV annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure -60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -Tedm #12 standard, #14 or # 15 Screws and 3" Drill -Ta6m steel plate or Drill -Tedm AccuTmc Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and.3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure --6Q psf, See General Limitation #7) NOA No.: 07- 121.9.09 Expiration Date: 11/04/13 Approval Date: 03/20108 Page 17 of 19 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -Te rm #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7j ily Sh is "' One or more plies ofS�AFG AS® PLY 4, WgiftLTIMA, RUBEROID® MOP Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate 4C :o .b4 '-z Cap Sheet: (Optional) y o AFGLAS' Mineral Surfaced Cap S or GAFGLAS a adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galJsq. 2. GAFGLAS Mineral Surfaced Cap Sheet, GAFGLAS Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbsJsq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 galJsq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT* MB +, TOPCOAT* Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 galJsq. 5. Leak BusterTM Matrikm 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote P roof coating applied at 1 to 1.5 galJsq. 6. TOPCOAT* Surface Seal, TOPCOAT® Fireshieldo SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07- 1219.0 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 18 of 19 WOOD DECK SYSTEM LIIVnr1rATIONS: 1 A slip sheet is required with Ply 4 and Flex PlyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum %" Dens DeckTM or %" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL U TATIONS: I . Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psL 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) S. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 911-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20108 Page 19 of 19 f- A v� ,x SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the �contractor. The owner's initial in the designated space indicates that the item has been explained. 1" /-2C?Aesthetics Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. y�Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. ae Ex" posed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appear ce. 5. vponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original ofing system is removed. Pounding conditions should be corrected. erflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. entilatlon: Most roof structures should have some ability to vent natural airflow through the Interior of the structure assembly (the building itself). The existing amo nt of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which ca ult in extending the service life of the roof. Owner /Agents Signature Date Contractor Signiffure J D to Revised on 719/2009 LD