Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-13-1178
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 192295 Permit Number: RF -5 -13 -1178 Scheduled Inspection Date: July 19, 2013 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: Wiborg, Brian Work Classification: Tile /Flat Job Address: 38 NE 108 Street Miami Shores, FL 33161- Phone Number Parcel Number 1121360110050 Project: <NONE> Contractor: HIGH & DRY ROOFING Phone: (305)542 -3194 Building Department Comments Infractio Passed Comments METAL AND FLAT ROOF INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. July 19, 2013 For Inspections please call: (305)762 -4949 Page 10 of 29 Miami Shores Village 'Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING FBC 20 / o Permit No. klIF Master Permit No ROOFING JOB ADDRESS: SS w�sk City: Miami Shores County: Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes OWNER: Name (Fee Simple City: Vk Z)M� Tenant/Lessee Name: Email: CONTRACTOR: Company Name: Address: m W v� city: Qualifier Name: 1 Zone: Y1 State: E G Zip: V�L zip: 6 Phone# � I— 9 State Certification or Registration #: Certificate of Competency #: MlAn- ContactPhone#: —3 654 0 Email Address: alb CA S'o.�i , unAi tg `fit Ca54 . DESIGNER: Architect/Engineer Phone#: Value of Work for this Permit: $ 150L Square/Linear Footme of Work: 'Z Type of Work: C1Addition DAlteration ONew l epair/Repl ODemolition Description of Work: _, � ), �`� � (�`1 n a� Color thru tile: Submittal Fee $ Permit Fee $ �5�i�® CCF $ CO /CC $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated promise in good faith that a copy of the notice of commencement and construction lien whose property is subject to attachment. Also, a certified copy of the recorded notice of for the first inspection which occurs seven (7) days after the building permit is issued inspection will not be approved and a reinspection fee will be charged. , Signature Signature -Owf or Agent value exceeding $2500, the applicant must v rochure will be delivered 4o the person mmencement must be posted at the job site In he absence of such posted notice, the Contractor The foregoing instrument was I acknQwledged before me 4s 4)h The foregoing instrument was acknowledged before me this 2 day of , 20 J by l day of 20 i , by &Uf--,W 0 + who ionallv known toe or who has produced who is orally kn to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: J MENENDEZ MY COMMISSION #DD9W4 EXPIRES: NOV 15, 2013 Sign: Banded throw let State In umce Print: My Commission Expires: ➢ ° 8 APPROVED BY i `_ �J Plans Examiner Zoning as identification and who did take an oath. NOTARY PUBLIC: y p`B4 J NIENENDEZ : MY COMMISSION #DD940274 EXPIRES: NOV 16,2D13 Sign: nded through It State Imsance Print: p My Commission Expires: 5 _ B Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06/10/200 )(Revised 3/15/09) It Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Property Date: Roofing Permit Number: Dear Building Official: I , 8 certify that I am not required to retrofit the roof to wall connections of my building because: ,The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) 1. ature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 9,4 da _ J MEP 96ii W COMMISSION i#DD94W4 EVIRES: NOV 15, 2015 Notary Public, Sate of Florida at Large " 8cnded #=ah 1st Sate lnsum= • When the just valuation of the structure for pure of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5121/2009 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION 2013RO438362 R E'.k 28659 Rs 1907P (fps) RECORDED 06103/2013 15131:52 HARVEY RUVINP CLERK, OF COURT PERMIT NO. TAX FOLIO NO.112136-011 -00W MIAMI -DADE COUHTYe FLORIDA LAST RAGE STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street / address. Single family home 38 NE 108 st. MWW Shores, FL 33161 2. Description of improvement: R&roof Ile to mew 3. Owner(s) name and address: Brian Wtmrg 38 NE 108 st. Waml Shores, FL 33161 Interest in property: NIA &Tt; vw T'&�roaw. Name and address of fee simple titleholder: ! MERE tee in tW a' 1 of � 4. Contractor's name and address. W IMO° "`' "" "` a ' !aura pl High & Dry Roofing Contractors, INC. 343 Was Dairy Rid, Waml, FL 33179 HARVEY RUVIN, CLERK, of Circuit Cg i `" 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address. NJA Amount of bond $ 6. Lender's name and address: N/A 7. • Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: WA 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: ire 9. Expiration date of this Notice of Commencement (the expiration date is 1 year from the date of recording unless a different date is specified) Sworn to and subscribed before me this 24 day of May , 20 13 Address: 11720 SW 113th Court, Miami, FL 33176 Notary Public: Print Notary's Name: Jessica Menem My Commission expires: Nov. 16, 2013 EZ J MENEND r n MY COMMISSION *DD940274 EXPIRES: NOV 16, 2013 Bonded Inrough Ist State lnsurm Property Information Map My Home Miami -Dade County, Florida Property Information Map Aerial Photography - 2012 0 - 112 ft This map was created on 5124/2013 11:36:02 AM for reference purposes only. Web Site © 2002 Miami -Dade County. All rights reserved. lol�� Page I of 1 MMI Summary Details: Folio No.: 11- 2136- 011 -0050 Property: 8 NE 108 ST Mailing BRIAN WIBORG Address: JAMES V\nBORG Beds/Baths: 8 NE 108 STREET MIAMI Floors: HORES FL Living Units: 3161- Prooertv Information: Primary Zone: 1000 SGL FAMILY - $75,421 101 -2300 SQ LUC: 0001 RESIDENTIAL - 150,3 234,19 INGLE FAMILY Beds/Baths: /2 Floors: 1 Living Units: 1 dj Sq Footage: 1,659 Lot Size: 9,225 SQ FT Year Built: 1952 $184,195 52 41 PB 52 -33 $50,000/ UNNINGS MIAMI egal HORES EXT NO 7 LOT escription: BLK 210 LOT SIZE $50,000/ 5.000 X 123 74R60772 IR 27216-20310310 19 Assessment Information: ear: 2012 2011 and Value: $75,421 $83,801 uildin Value: arketValue: $150 270 $225,691 150,3 234,19 sessed Value: $225,691 234,195 Exemption Information: ear: 2012 2011 • $25,000 $25,000 Eomestead: nd Homestead: I YES YES Taxable Value Information: Year: 2012 2011 $223,500 Applied Applied Taxing Authority: Exemption/ Exemption/ trustees in bankruptcy, Taxable Taxable Value: Value: Regional: $50,0001 $50,000/ $175,691 $184,195 County: $50,000/ $50,000/ $175,691 $184195 City: $50,000/ $50,000/ $175,691 $184,195 School Board: $251000/ $25,000/ $200,691 $201195 Sale Information: ale Date: U201 0 Sale Amount $223,500 Sale O/R: 7216 -2031 Sales Deeds to or executed by Qualificati on trustees in bankruptcy, Description: executors, guardians, or receivers View Additional Sales http: / /gisirns2 .miamidade.gov /myhome /printmap. asp? mapurl = http: / /gisims2.miamidade.go... 5/24/2013 DIWIARThEMI F BUSII�SS AND PROFESSIONAL RLGW ATION CONS U' CT:XON INDUSTRY LICENSING BOARD SE(,# L120827016T2 3 .. _ LICENSE NBR_ "08 21 .2012 J1.2805-629:6 CCC13292�7 3 12 -01 -2011 JEFF ATWATER STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION CERTIFICATE OF ELECTION TO BE EXERT FROM FLORIDA WORKERS COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 10/14/2011 PERSON: LUCERO FEIN: 270934750 BUSINESS NAME AND ADDRESS: HIGH & DRY ROOFING CONTRACTORS INC 343 IVES DAIRY RD #6 MIAMI FL 33179 SCOPES OF BUSINESS OR TRADE: 1— CERTIFIED ROOFING CONTRACTOR EXPIRATION DATE: 10113/2013 GUSTAVO H IMPORTANT. Pursuant to Chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05112?, F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed on the notice of election to be exempt Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt aad certificates of election to be exempt shalt be subject to revocation if, of any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no touger meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of ibis section. QUESTIONS? (850) 413 -1609 OWC -252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01 -11 CERTIFICATE OF LIABILITY INSURANCE °A� 5/01/1 Y'�' 05/01/13 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION 1S WANED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Get Smart Insurance Ina 19321 N.W. 2nd Ave Miami, FL 33169 Phone (305)653 -7977 Fax (305)654-0293 CONTA_ CT Gregg OibJan FR. %o. M5)653-7977 Not (305 293 L AnnRES& Info insure -smart corn INSURER(S) AFFORDING COVERAGE NAIL 0 uNSURERA : Preferred Contractors Insurance Company, RRG GENERAL LIABILITY © COMMERCIAL GENERAL LIABILITY ❑ ❑ m A DE ® OCCUR ❑ INSURED High & Dry Roofing Contractor; Inc / Gustavo Herman Luc em 11720 S W 113 Court Miami, FL 33176 (305) 542 -3194 INSURER B 03/21/2013 INSURER C : EACH OCCURRENCE INSURER 0: PREMISES E .....= INSURER E: MED EXP (Any one person) INSURER F• PERSONAL &ADV INJURY COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. 1 TR TYPE OF INSURANCE ADD N Ulm POLICY NUMBER POLICY EFF POLY EXP VGA G TZar I N23G A GENERAL LIABILITY © COMMERCIAL GENERAL LIABILITY ❑ ❑ m A DE ® OCCUR ❑ N PC87481 03/21/2013 0312112014 EACH OCCURRENCE $ 1,000,000.00 PREMISES E .....= $ 50,000.00 MED EXP (Any one person) $ 5,000.00 PERSONAL &ADV INJURY $ 1,000,000.00 ❑ GENERAL AGGREGATE $ 2,000,000.00 GEN'L AGGREGATE LIMIT APPLIES PER 0 POLICY ❑ PB ❑ LOG PRODUCTS - COMP /OP AGG $ 1,000,000.00 BUPD per claim Deduct $ 1,000.00 AUTOMOBILE LIABILITY ❑ ANY AUTO ❑ UTOOSS LA BOSS ❑ HIRED AUTOS ❑ tANO�P1� EU ❑ Ea ntSWGLE LIMIT BODILY INJURY (Per fin) $ BODILY INJURY (Per ao t) $ ,r �GE $ $ ❑ UMBRELLAIJAB ❑ OCCUR ❑ EXCESS LIAB ❑ CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED ❑ RETENTION $ $ WORKERS COMPENSATION AND EMPLOYED' LIABILITY YIN ANY PROPRIETORIPARTNERfEXECUTIVE OFFICERIMEMBER EXCLUDED? (M In H) El DESCRIPTION OF OPERATIONS below N I A ❑ MA 1:1 OTH EL EACH ACCIDENT $ EL DISEASE - EA EMPLOYE $ E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS / LWATIONS / VEHICLES (Akach ACORD 101. Additlmral Remarlus Schedule, ff more spso® is required) Roofing CERTIFICATE HOLDER CANCELLATION ©1988 -2010 ACORD CORPORATION. All rights reserved. ACORD 25 (2010105) QF The ACORD name and logo are registered marks of ACORD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Miami Shores Village THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Ave. Miami Shores, FL 33138-2304- - 2304 AUTHORIZED REPRESENTATIVE A' G TZar I N23G ©1988 -2010 ACORD CORPORATION. All rights reserved. ACORD 25 (2010105) QF The ACORD name and logo are registered marks of ACORD -- ifi76�F7= FELii.",�ff,i ist !'LOOK kAiJST #s DISfiLAYED AT Pl ACE OF BUSINESS RAIAftl►1, FL 3313fl PURSUANT TO COUNTY :ODE CHAPTER 0A -, , .0& is 651839 -4 THIS IS NOT A BILL — ISO NOT PAY BUSINESS NAME I LOCATION HIGH & DRY ROOFING CONTRACTORS INC 343 IVES DAIRY RD 6 33179 UNIN DADE COUNTY OWNER HIGH & DRY ROOFING CONTRACTORS Sea. Type of Bushmss 196 SPECIALTY BUILDING CONTRACTOR US IS ONLY A LOCAL JSINESS TAX RECEIPT: IT )ES NOT PER80T THE 3LOER TO VIOLATE ANY OS'MIe RMLATORY OA PAID MtAML FL PERMIT NO. 231 RENEWAL RECEIPT NO. 678876 -5 STATE# CCC1329237 WORKER /S 1 MMO LAWS OF THE DO NOT FORWARD mm" OR eggs. NOR 3ES R EXEMFrr THE 3LOER MOM ANY OTHER Rata OR LICIENSE T°17A°tEERT04M� OF HIGH & DRY ROOFING CONTRACTORS iE iHOLOE" ° °AUFM- INC GUSTAVO H LUCERO PRES WLAR T„� 343 IVES DAIRY RD 6 MIECTOM MIAMI FL 33179 10/1512012 000082.50 09010089001 00082 500 1 111111111! 1aTaliiaaa811 !3 Its 11iaa'iatiaiaa1aa 1111111 11111 lw SEE OTHER SIDE V WUV1 D 1V Ut1LJ& U t7U V V1L1 11 V 11G GV 1 V MIAMh�ADE "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. __ �k. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. EE�"enailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Buil ' Code. (The roof deck is usually concealed prior to removing the existing roof system). . Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. . Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. . Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected _w scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 15 and 16 herein and the Florida Building Codes Plumbing. Mi. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida- licensed engineer or registered architect to eliminate the attic venting, venting shall npt -bee required. Owner's /Agent's Si � Contractor's Signature: Property Address: Date: Permit Number: -- - - ■® ■ r ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form. Section C Low Slope Application) Fill In specific roof assembly components and Identify manufacturer (if a component is not useA Identify as "NA ") System Manufacturer. Product Approval No.: Design r2- A urea, From R 128 or Calculations Pmax1 • Pmax2• /e Pmax3: Max. Design Pressure, from the specific Product Approval system: ,j 7 •, Deck: Type: �! =P Gaugelfhic fkness• Slope: �/ l AnchorBase Sheet & No. of Ply(s): Lkim Anchor ise S eet F tenet! �� n ing Material: Cqz `.� e Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation FastenedBonding Material: Top insulation Layer: k t 1AA Top Insulation Size and Thickness: r a Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): & Base Sheet Fastener /Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheettt Attachment: Field: —I—" oc @ Lap, # Rows @ 1 " oc Perlmetet�" " oc 7" @ Lap, # Rows @ " oc Comer: " oc @ Lap, # Rows @ " oc Number of Fasteners Per Insulation Board: Field He/m?k— Comer Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Penult Application Form. Roof System Manufacturer: q Notice of Acceptance Number: I t —1102- -C) Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations) 11 • p� P2• P3•® Maximum Design Pressure (From the Product Approval Specific Systnt): Deck Type: I m T -G l es m Type Undedayment: Roof Slope: Insulation: Fire Barrier: - ° Q. Ridges Veenfilation? Fastener Type & Spacing; �I • � ; / °� ®® 12 Adhesive Type: Type Cap Sheet: I W N FLORIDA BUILDING CODE — BUILDING IIEscpI MON: Std ISM Mechanically Setned Fuel I.ABTi Mw. Each unit shall bear a permanent label with the mantuhctttrer`s name or logo, city, state and following statement "l1diarmi Dade County Product Coirtroi Approved, unless otherwise Hotel herein. REAL of this NOA shall be oonsidewd aft a reawai a ication bas been filed and there bos been no cha V in the applicable building rude negn&* acting the prance of ibb MA" +'RMM TION of this NOA will oem after the =g6adon date or if them has been a mvi=n or charip in the mawrials, use, aadlor man of dw pmduCt or procem Misuse ofthis NOA as an Of any grand for sales, advertising or -any other purposes shall aUtDnM hCIdIy ternnirtate this NOA. Failure to comply with any section of this NOA shall be cause for won and removal of NOA. ADVER1T=A=T: The NOA number preceded by the words Miami Dade County, Florida, and followed by the exphattfon date may be displayed in advertising Meratme• If any p"don of the NOA is displayed. then it shall be done in its entirety. INSPECTION: A copyof this enters MA shall be provided to the uNw by the mamfacu= or its diftib w ud da. be available for hVccf II at tt A ft at the req" Of 9e E Wft This revises NOA# 09- 0310.04 and. of pages 1 dnvgb. 7. Tits submitted d t. was reviewed by Ales Tiga. li t RV4FING ABLY APPROVAL: Pawl Clip Stainless Steel Panel Clip Height I-r min. 24 gage (0-02397) 1 =2" w =r h= 13" min. 24 ,gage ( ©.0239") 1 =2" W —r h= 13" min. 24 gage (0.0239") TAS 110 ASTM Ora& 50 prey, WWab c md clips with two prefamied 1. TAS 110 Grade C preformed, smintess steel clips with two p refold bales. TRADE NN,4r*M OF PRODUCTS MANUFACTUP" BY OTIOUM Product Fasbencrs #10 Cam rc&mtmg steel scar+ m for baeving of Clip. MA,NDFA.CTURiNG LOCATION`. 1. Vii, FL. EVIDENCE SUBMITTED: Test Asmev Test IdgedOw Yalspar Cation �: AM- WI -01 -01 0299-0841 -03 02"- 0320.04 T,0- NaaaadRmaort ASTM 0 23 ASTM B 117 TAS 100 TAS 125 TAS 125 Dab 08/18103 10127/43 O3l25104 NOA Na z. 1.1- M 1 W B'7 /14 Appravid Date: 84WI2 pap 2of7 AFF80VED ASSENMLIRS: System A: Stad I.5" Modbanicaily Seamai Pawl OwCwan 2(r coveuV WM Pawls) Deck Tye: Wood, No r- iml td DakDalcrIOW; NW Cow 19/327 or greaW p atr wed plank, or for re- roofing '5/327 (W V=dff PAYW o Slope Ram :2":12" or gmw Maalmm Ups : See Table A below D essum en III acme wilt table g ' but in >� cwc it sl�tll be Im that 8d modarring sly nos space =d 6' o c. in ac field and 4" o c a the per of the shect in rarcwfmg, where &a deck is less Then 19132'° thick (11ininumn 15!32') The, above a mama be is addrWon to MUStMg amt - Underhiymenft Minim undmigymmt shall be a ASTM D 226 Type 11 iodalld wish a udnimunai 4°' side-laps and 6" =44aps. Undedayment shall be bstmed vA corrosion r and 1'/" am rn8-Aank nmils, Wced 6" u c. at all laps and two rows 12" o c. m the field of *e roll.. Or. any Amami. `;, Da& Cbunty Pwd=t .Cwhol Approved undadayment having a cuffent XOA_ Dire Barrier Board; Any approved fue bauicr having a cumvnt NOA. Refer to a dent fire directory lisfift for fife t8fings o €#leis raufmg s lY as wdl as tine location of the fire barrier within &c assembly . See Limitation # 1. i Valleys: Valley on shall be in compliance with Roofing A pficatioa Sid! RAS 133 and with Ma}tnr's Metal Roofing & COAM Skeet M Inc-'s t publMed fi sialla ion itiArOC&M Mdtai 1" aneis and install the " Steel 1S" Manic ally Steed Pau" and pies m Accessories: coulpliance with Magma's Metal Roofing & Shed Metal, Ans.'s c published instaIlatic►a insft�aons and de'ls. valley cation and other details shall be mwnuftd m eenipliance, with the 133. mblingagn ' provided in Roofing A� Panels shall be hu taller with ww=wswwm st&-I clips (2" lwg x r w x sted IS" tom, to to with ton # of i see of t lang& genet 3/16". Clip shall s� 3" from panel end and shall be at I ` sgacing m d below in Table A. there afro: Stn aft scum slmall be 1.�„�,•Qth. „ t t., 9'ntl + seam. (Gbw)e lockj. PIOA Pia: 11: Fxgnratka 1 7114 A val Duft Of 7 TABU A MAmum DzSIGIV PRESSURES RveiAreas F3ieh1 Perixneter aund Lorimer' maxim. Desimpressures -57.3 —101 Mamhmum CHP spacing 34" oe. oc. 1. Exnwkdon sbalt A be allowed PIOA Pia: 11: Fxgnratka 1 7114 A val Duft Of 7 O rp No"- LR TATIONS L rim clew is nm part Of this ; reftto acaarod Approved S. All products liswd herein shall have a quality amuance audit m sacmdanc a with the Florida Buiidmg Code and Rule 9N-3 of dw Flod&Admndgmtm Code- f O.Sr DETAI L DRAWD" 0 " _ s 17, lir &?A" -- PANEL DETAIL HOUMFOR 1 IBM PANEL CLIP DETAIL STEEL 1.5" 1 CFXHANi -ALLY SEAPAWD PANEL AND DR'rA S NOANa.:11- 1Z02.O:i ZxpkwWuDzwWl7114 gap6W7 DRAWINGS COW. STANDING SEAM PANEL EM OF THIS ACCEffANCE- f NOA Na: EMMASOM DRW Ofill7j04 OWO . 502 Appr*VABste*- 7,07 i} 1 f t I PANEL CLIP WITH SCREWS - ROOF PANEL BUTYL TAPE UNDER CONTINUOUS CUP - VALLEY FLASHING 3Q# FELT PAPER & VERSASHIELD VALLEY DETAIL STEEL (24 Ga.) - STANDING SEAM PANEL i 3" RAKE FLASHING 34# FELT PAPER 010 %.,un PLYWOOD 1 1/4" RING SHANK ROOF NAIL 4" O.G- STAGGERED RAKE DETAIL STEEL (24. Ga.) - STANDING SEAM PANEL R GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: VersaShielda Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 10- 0331.04 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 11- 1110.09 q Ezpiration Date: 02107/17 Approval Date: 01/26/12 Page 1 of 3 MIAMl- MIAMI DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175 -2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315 -2590 F (786) 31525 -99 NOTICE OF ACCEPTANCE (NOA) .miamidade.gov /sera GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: VersaShielda Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 10- 0331.04 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 11- 1110.09 q Ezpiration Date: 02107/17 Approval Date: 01/26/12 Page 1 of 3 I ROOFING COMPONENT APPROVAL Category_ Roofing Sub - Category: Underlayment Material: Fiberglass SCOPE: This acceptance is for VersaShield Fire Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and VersaShield® Solo Fire Resistant Slip Sheet (a.k.a "VersaShield Solo "), as described in this Notice of Acceptance, for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Product Dimensions Test Product Specification Description VersaShield® Fire 42" x 100' rolls ASTM D 226 Type II Non - Asphaltic fiberglass -based Resistant Roof underlayment and/or fire barrier. Deck Protection VersaShield® Solo 72" x 166.7' rolls UL790 Non - Asphaltic fiberglass -based slip Fire Resistant Slip sheet and/or fire barrier. Sheet MANUFACTURING LOCATION: 1. Conover, NC EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GAF- 270 -02 -02 ASTM D 226 11/15/10 ELK - 063 -02 -01 TAS 100 09/27/01 Underwriters Laboratories Inc. 99NK45831 UL790 03/21/00 l ONK11990 UL790 05/18/11 R19254 ASTM D 226 09/13/01 08CA37926 UL790 09/23/09 08CA49140 PRI Asphalt Technologies, Inc. ELK - 069 -02 -01 TAS 100 03/04/02 BRY- 003 -02 -01 TAS 117(B) 03/19/02 BRY- 003 -02 -01 TAS 114 (H) INSTALLATION: 1. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet shall be installed with a minimum 4 -inch head lap in a shingle layer fashion. 3. VersaShield® Fire Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type R underlayment. NOA No.: 11- 1110.09 Expiration Date: 02/07/17 r� fflzo� couNrr Approval Date: 01/26/12 Page 2 of 3 LpArrAnONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield Fire Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. VersaShield® Solo Fire Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield® Fire Resistant Roof Deck Protection and VersaShield Solo Fire Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet may be used with any approved roof covering Notice of Acceptance listing. VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet may be used as a component part of an assembly in the Notice of Acceptance. If VersaShield Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 6. VersaShield Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet are a non - asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of specific roof assemblies using VersaShield® Fire Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N -3 of the Florida Administrative Code LABELING: All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and yellow line to identify the ASTM Standard designation; or logo and the following statement: "Miami - Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. APPROVED BUILDING PERIVHT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE NOA No.: 11- 1110.09 Expiration Date: 02/07/17 Approval Date: 01/26/12 Page 3 of 3 ii�► M BUILDING CODE COMPLIANCR OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation. 1361 Alps Rand Wayne, NJ 07479 MIARG -DADS COUNTY, FLORIDA WIRO -DADE FLAQ.ER BUILDING 140 WEST FLAGLEB STREET, SUM 1603 MAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Budding Code and Product Review Comtnifte to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assu`ance purposes. Wthis product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such terming and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as desenW herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. JDESGRR'TION: GAF Conveatlonal BuWUp Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "AGami- -Dade County Product Control Approved ", unless oflmwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been fug and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration daft or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be causes for termination and removal of NOA. ADv=TISKmzNT: The NOA number prmeded by the words Miami Dade County, Florida, and followed by the expiration daft may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INNSPEMON: A copy of" entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Budding Official. This NOA renews and revises NOA No. 43- 0501.05 and consists of pages 1 gh 19. The submitted documentation was reviewed by Jorge L. Acebo. NOA Nw 07-1219.09 Kxpiratbm Datc; 11AW13 Apprt►val Date: MOM Page 1 of 19 R 146 Deck Type 1: Wood, Rion - insulated - Duck Deneription: '91 ,2" or greater plywood or wood plank decks System Type A: Base sheet mechanically fastened. All General stud. System Limitations shall apply. Hire Barrier. Fkr,(XtTM Fire Barrier Coating, VersaSIMeNon- Asphaltic Fiberglass -Bad (optional) Underlayment or SecnmckTM. s GAGL�RUB�BRO TMm s STRATAVEdTO EiminatorTm y , RUBEROID" 20, RUBEROID® Heat Wektm Smooth or RUBEROIDO Heat Weldm 25 base sheet mechanically fastened to deck as described below; Fastening Options: - GAFGLAS* Ply 4, GAFGLAe Fleas P1ym 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring.shank nails and tin raps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (MwdmumDeW8n Pressure 4S p.E6 See General LimSadon #) GAFGLASO Ply 4, GAFGLAS* Flex Piyra 6, GAFGLASP #75 Base Sheet or any of above Base sheets attached to deck with Drill -Tedm #12 standard, #14 or # 15 Screws and 3" Drill -Ter'm steel plate or Drill -TecTu AccuTrac Plates, 12" ox. in 3 rows. One row is in the 2" side lap. The other rows are equality spaced approximately I2" o.c. in the field of the sheet. (M=knam i7asign Pressure-- 4SpSf, See Geriternl Limkatdon #?) GAFGLAe Flex Ply's 6, GAFGLAS0 #75 Bass Sheet or any o above B sheets attached to deck with approved annular ring shank nails and ten caps at a fastener spacing of 9" o.c. at the 4" lap staged and in two rows 9" o.--. in the field (Mwdmum Do*n Pressure 515 psf, See GeweW IAW* don #7) GAFGLAr #80ULTIMATm, RUBEROIDu20, RUBEROID` Mop Smooth, bye sheet attached to deck with approved 1 VV annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" ox. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Mwdmum De*x Pressum — 69psf, See General Li udadon #7) GAFGLAS* #75 Base Sheet or any of above Base sheets attached to deck with Drill Terra #12 standard, #14 or # 15 Screws and 3" Drill -TecTa steel plate or Drill -Te6m AccuTrar Plates, 12" ox. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet: (M=hnAm Dgtgn Pressure —0PS, f, ,See General Li ukad +n #7) Any of above Base sheets attached to deck approved armular ring shank nails and:3" inverted Drill Teem insulation plates at a fastener spacing of 9" o.c, at the 4" lap staggered in two rows 9" in the field. (Maaatmum Design Pressure --M pS, , See GenwW Lb*atlon #7) ATOM No„ 07- 1219.$9 ER*8tM DMw 1lf"113 Approval Date: 031UM Page 17 of 19 W 1. Gravel or slag applied at 4001bsJ9q. and 300 Wsq. respecdVely in a flood coal of approved asphalt at 60 lbsJsq. or applied in a floe coat of Leak Bustaerrm MairinTm 103 Cold Process Adhesive applied at a rate of 3 galh(l. 2. GAFGLAS* Mineral Surma Cap Shut, GAFGLASu Energy Cap Mineral Surf teed Capsheet aMered in a foil mopping of approved asphalt applied within the EW range and at a rate of 20-40 %sJsq. 3. Leak BusterTm MatdxTm 303 Premium Fibered Aluminum Roof Coating, at 1.5 galdsq. 4. Leak BuAwTm MatrixTm 715, Leak BusWTm MatrixTm 322, TOPCOATS' MB +, TOPCOATO Ftreshield Elastommic Roofing Membrane, applied at 1 to 1.5 galJsq. 5. Leak BusterTU Matftm 602 MB Xtxra Elastomedc Roofing Membrane, EnargyCote.* roof c6ating applied at 1 to 1.5 galJsq. 6. TOPCOAT Surface Seal, TOPCOAT Fiteshiele SB Solvent based Elastomeric Roofing Membrane applied at Ito- 1-5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applieable Building Codes. Maximum Design Pressure: See Fastening Above NOA Na: 07- 1219.09 Lxpirstion Dste: 11104!13 APPI091 Daft 43124 .Fogs 19 of 19 WOOD DECK SYSTFm LumATIONS: 1 A slip sheet is required with Ply 4 and Flex P1yTm 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum W Dens DeekTw or �V Type X gypsum board is acceptable to be installed dirw -* over the wood deck. GENMIAL LYWrATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings ofthis product 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be V x V maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over clod cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base shut shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" ox.; or strip mopped Ir ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every LT in each ribbon to alloy doss ventilation. Asphalt application of either system shall be at a minimum rate of 121b sJsq. Note: Spot attaeW systems shall be blotted to a maximmn design pressure of -45 pat: 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf:, as tested in compliance with Testing Application Standard TAS 105. N the fastener value, as field - tested, are below 2751b£ insulation attachrrxn t shall not be acceptable. 6. Fastener spacing for mechanical attachment of anebor/base sheet or membrane attachmeat is bpi on a . minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the farmer resistance be lew than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architewat or Registered Roof Consultant may he submitted. Said revised fastener spacing shall utilm the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculate in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and seated by a Fkxida rogisWrod Professional Engineer, Registered Architect, or Registered Roof Consultant (Wben this Umhati tt is speei wHy referred within this NO.A, GeaerIal LimitatiDa #9 will not be applicable.) 8. All attachment and sn mg of der nadw% metal profile, and/or flashmg termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enliweed ring at enhamwd pressure zom (Le. paiimewM alatded comers and tonne). (Wirer this limitation Is sp ecill ally ref and within this NOA, General LW3ita*n #7 will not be appUable.) 14.. All products listed herein shalt have a quality assurance audit in asceordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA 1Vo.: W-1219.09 Expi mflon Dsty 11!04/13 Approval /late: MW Page 19 of 19 TGFU.R21453 - Roofing Systems Page 1 of 2 ONLINE CERTIFICATIONS DIRECTORY TGFU.R21453 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems MAJORS METAL, ROOFING & CUSTOM SHEET METAL INC R21453 406 NW 54 ST MIAMI, FL 33127 USA Any UL Classified peel and stick underlayment may be used in conjunction with either "VersaShield" or a Type 30 base sheet, in any of the following systems. OTHER SYSTEMS Class A 1. Deck: C -15/32 Incline: Unlimited Barrier Board: — G -P Gypsum 1/4 in. min DensDeck ® board or 1/2 In. min. UL classified gypsum board with all joints staggered a min of 6 in. from the plywood joints. Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base /ply sheet, Type 15 or 30 felt or UL Classified prepared roofing accessory or WR Grace "Ice and Water Shield ". Surfacing: — "Copper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels, "Aluminum 1.5" Mechanically Seamed panels" or "5 Crimp" panels, mechanically fastened. 2. Deck. C -15/32 or spaced sheathing Incline: Unlimited Underlayment: — O� layer Elk Corp. "1fersaShleld Underta mechanically fastened. Ply Sheet: —One layer Type 30 base shee or ersaShietd ", mechanically fastened. Panels: — "Cooper 1.5" Mechan ca y Seamed panels, "Steel 1.5 Mechanically Seamed" panels or "5 Crimp" panels, mechanically fastened. 3. Deck: C -15/32 or spaced sheathing Incline: Unlimited Underlayment: — One or more plies Elk Corp. "VersaShield Underlayment", mechanically fastened. Panels — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels, or "5 Crimp" panels, mechanically fastened. 4. Deck: C -15/32 Incline: Unlimited Underlayment: — Two layers Elk Corp. "VersaShield Underlayment ", mechanically fastened. Panels — "Aluminum 1.5" Mechanically Seamed Panels ". Class B 1. Deck: C -15/32 Incline: Unlimited Underlayment~ — One layer Elk Corp. "VersaShield Underlayment", mechanically fastened. Panels: — "Cooper 1.5 " Mechanically Seamed panels, "Steel 1.5" Mechanically Seamed panels, "Aluminum 1.5" Mechanically Seamed Panels ", or "Scrimp panels mechanically fastened. 2. Deck: Spaced Sheathing incline: Unlimited Underlayment: — One layer Elk Corp. "VersaShield Underlayment". Panels: — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels or "5 Crimp" panels, mechanically fastened. Class C 1. Deck: C -15/32 Incline: Unlimited Vapor Barrier (Optional). — Any UL Classified base /ply sheet. Surfacing: — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5" Mechanically Seamed panels, "Aluminum 1.5" Mechanically Seamed panels or "5 Crimp" panels, mechanically attached. Last Updated on 2013 -04-22 Ouestions? Print this pane Terms of Use Page Too http:// database .ul.comlcgi- bin/XYV /templatelLI SEXT /1 FRAME /showpage.html ?name =T... 5/24/2013 Al 306 - Roofing Systems 1. Dacia C -15/32 -V-� L� Claw A 1-777-MrW Cm -F Page 1 of 1 Insulation (optional): — one or more layers periite or wood fiber or glass fitter or polyisocyranurate or Urethane or pertite/polylsocyanurate composite or perlite/uretfrane co or wood fiber/polyisocyanurate Composite or phenolic, any thickness- ply Sheei: — Three or more plies Type G1 or "GAFGLASO Ply 4° or 'Trl -Ply® Ply 4° or "GAFGLASO Ply 6" hot mopped. Surfacing: — Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perilte/polyisocyanurate composite or lerlite WVUMne composite or wood f /polylsocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more pries Type Gt or 'GAFGLASO Ply 4" or'Tri -l" Ply 4" or "GAFGLASO Ply 6 ". Cap Sheeb — One ply Type G3 "GAFGLASO Mliwal Surfaced Cap Sheet" or "iri -Ply® Mineral Surfaced Cap Sheet" or "GAFGL.AS® EnergyCap7 ° BUR Mineral Surfaced Cap Sheet." 3. Dacia NC 7 = Insulation (Optional): — One or more layers perlitae, wood fiber, glass fiber, IOYISDcYanurate, urethane, per WPOlylsoryenurate composite, perrite/urethane composite, wood fits /poiytsocyanurdte composite, Phenolic, 2 -in. maximum. Ply Sheet: — Two or more plies Type GI "GAFGLASO Ply 4 °, °Tri-PW Ply 4° or %WGLAS@ Ply 6 °. Cap Sheep — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri4W@ Mineral SurMced Cap Sheet° or °GAFGLASO En&WCVm BUR Mineral Surfaced Gap Sheet." 4. Deck C -15/32 India: 1 Slip Sheet (Optional): — Red msin paper, nailed to deck. Insulation (optional): — Any thickness perhte or wood fiber or glass filer or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified ins Won adhesive. Mgt ne Type Sheet° (may be milted). or more piiType Gg Ply Type GGAfGL Cap Sheet" or "GAFGLAS@ Mineral Surfd —Cep naf): — °TOFCOAT� EnergyCobe/Pf° appied at a rate of 2- ga!/l0o -fta. S. Deck NC Base Sheri — one ply Type G2 "GAFGLASO #75 Luse Sheet° or 'Th-PlyO #75 Base Sheet°. Pty Shwb — the or more plies Type G1 "GAFGLASO Ply 4" or "Tri -PLyo Ply 4" or "GAFGLASO Ply 6. Cap Sheet: — One ply Type G3 "GAFGLASO Mineral Surfaced Cap Sheet' or "Tri -Ply® Mineral Surfaced Cap Sheet" or °GAFGI.ASO EnergyCap' BUR Mineral Surfaced Cap Sheet." 6. Dacia C -15/32 Incline: 2 Insulation: — One or more layers periite, glass fiber, polylsocyanurate, urethane, Perift /polyisocyanurate composite, pedWurethane composite, phenolic, 1 in. minimum (offset a minimum of 6-In. from plywood deck joints). Base Sheet: — one or more pries Type GI or Type G2 or Type G3. Hembrane: — one or more pries °Ruberobd® Torch Smooth" or "RuberoidO Torch Granule" or "Ruberold® Torch Granule Plus° or "RuberobdO lop Smooth" or °Ruberoi l@ Mop Smooth 1.5" or °RUberok* Mop Smooth Plus° or "Rubin -Ok* Mop Gra nine" or °Ruferoid® Mop Plus Granule" or "ROOFMatrht SBS Modified Granular" or *Td-Ply® SBS Modified Bitumen Membrane° or °ROOFMatch" APP Modified Granular" or'Tri- PlyCal TP-4G" or °rd -Ply® TP-4° or "Ruberoede Dual Smooth ". Cap Sheet: — Type G3 °GAF'GLASS Mineral Surfaced Cap Sheer or 'Tri- PlyCal Mineral Surfaced Cap Sheet or °GAFGLASO EnergYC301" BUR Mineral Surfaced Cap Sheet" fully adhered with hot ring asphalt. 7. Deck C-15/32 Incline: 2 Insulation (Optional): — One or more layers perlite or wood fiber or gbss fiber or polywocyanurate or urethane or perIWpotyisocyanurate composite or pertite/urethane composite or wood flier /ptyLsacyanurate WmPosft or phenolic, any thldmess. Base Shy — Two or more plies Type G2 or Type G3. Ply Sheet (Option): — One or more plies Type GI. Membrane: — One or more plies "Ruberolde Torch Smooth" or °Ruberoi [O Torch Granule" or "RuieroldO Torch Granule Pius° or "Rubemtd® Mop Smooth" or "RuberoklO Mop Smooth 1.5" or °RuberoidO Mop Smooth Plus° or °RUberokl@ Mop Granule° or °Ruberoid* Mop Plus Granule' or °ROOFMatch— SBS Modified Granular" or "Tri-Ply® SBS Modified Bitumen Membrane° or °ROOFMatchTM APP Modified Granular" or °Tri -Ply® TP-4G" or °TH My@ TP-4° or °Ruberoklo Dual Smooth ". Cap Sheep — Type G3 'GAFGLASO Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet° or °GAFGLASS EnergyCaOm BUR Mineral Surfaced Cap Sheet° fully adhered with hot roofing asphalt 8. Dacia NC l j i17W Insulation (Optional): — Partite or glass fiber or polyisayanurate or wood flier or mechanically fastened, any thickness. Base Sheet: — one or more piles Type G2, "GAFGLASO #7S Base Sheet° or "Tri- Pty® #75 Base Sheer. Ply Sheer — One or more plies Type GI "GAFGIAS® Ply 4" or'Tri -Ply® Ply 4" or "GAFGLASO Ply 6 . Cap Sheet; — Type G3 "GAFGLASO Mineral Surfaced Cap Sheet° or `TO-Ply@ Mineral Surfaced Cap Sheet" or GAFGLASO EnergyCaP- BUR Mineral Surfaced Cap Sheet° fully adhered with hot roofing asphalt. surfachW: — °Flreshield MW applied at 2% to 3.0- ga1.11004e. hnp: / /databaw.ul. coin/cgi- bWX- YVhemplate/LISEXT /i FRAM]E/showpage.html?name =T... 5/24/2013