ELC-13-0793Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 203882 Scheduled Inspection Date: February 19, 2014 Inspector: Devaney, Michael Owner: CONDOMINIUM, SHORES Job Address: 1700 NE 105 Street Miami Shores, FL Project: <NONE> Contractor: AUSTEN ELECTRICS eunaing Department comments Permit Number: ELC-4- 13-793 Permit Type: Electrical - Commercial Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1122300500010 Phone: (305)805 -8166 ELECTRICAL REPAIR TO ELEVATOR MACHINE ROOM Infractio Passed Comments AND PIT I INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP- 203789. CREATED AS REINSPECTION FOR INSP- 189525. 2 dec. 2013 Failed ❑ Fire and drywall need to be finished first. Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. February 18, 2014 For Inspections please call: (305)762 -4949 Page 16 of 53 �3 -c) l' Of e5• V BUILDING � Miami Shores Village m , APR 1 7 2013 6u Building Department RY o o7- 7.- __oomo 7 f0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 �q Permit No. w 1 PERMIT APPLICATION FBC 2004 Master Permit No. Permit Type: Electrical ` -a / / �% Owner's Name (Fee Simple Titleholder) I n /top r- ���.`v'y+ j Phone # � J Ylqv Owner's Address 0 C /v G- C M IQ M, --.34,00-L5--S State ( Zip ;S Tenant/Lessee Name Phone # E -MAIL: Job Address (where the work is being done) / G"G A- J 0 :' City Miami Shores Villaee County Miami -Dade Zip FOLIO / PARCEL # i I - 272- �!) 0 ` ` 0 _<`0 — C C lT° I Is Building Historically Designated Contractor's Company Name Contractor's Address few YES NO I r �rtvti i -�'' hog City &o4 f � e h __®®�� State Imo/'. Zip `3 -� 0 t � Qualifier Name o- 77i`di,-� ,na Q rw ¢ c-� Phone # Z -- e01- -414 -6 State Certificat or Registration No. Certificate of Competency No. E-MAIL: Z- Si- CW A-Ld ( x';73 co Architect/Engineer's Name (if applicable) (IA Phone # Value of Work For this Permit $ Square / Linear Footage Of Work: Type of Work: []Addition ❑Alteration []New Repair/Replace ❑ Demolition Describe Work:: /4'U a d, �, x, ��Fees, �, �, �, ��, ��, �, ���, �, �, �, ar, �, �, ��, a, �, �, a�, ��,�,��,��,��,��,��,�,�,�,�,�,t Submittal Fee $ Permit Fee $ y, rAo CCF $ CO /CC Notary $ Training/Education Fee $. Scanning $ Radon $ DPBR Bond $ Code Enforcement $ Structural Review. S Technology Fee $ Zoning $ Double Fee $ Total Fee Now Due $ See Reverse side -> X Or-010 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) 7 - Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding 52500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature - Owner or Agent The fore oing instrument was acknowledged before me this day of f4ad , 2013 , by L1 �LS in zrr►e, who is per sonall wn to me or who has produced Signature Contractor The foregoing instrument was acknowledged before me this day of 20 Imo, by J C Skcmbw Q. who is personally known to me or who has produced As �i$Id4�1 as i c an oath. d0 ° Notary Public State of Florida e No NOTARY PUBLIC: :� Josephine Traber NOTARY PUB G y, lorS' P° since Florida My Commission EE080971 • Josephine Treiber of IV ° Expires 05/1012018? My Commission EE080971 A Expires 05/10/2015 Sign: 1— - _�" Sign: Print: �se�Yt,n�•"�ea� Print: My Commission Expires: +s 1 O E l My Commission Expires: ! ( 0 1 t -57 t�r�rakaYs4, r& �e, tvkdr�r�r�e�ir�ir�r�t�r�Y�te, u�k�et, rsk�e�k�Yaa4, t+ YJesk�esk�iie�4�r�kde�r�k ,t�tea4 &�iraY�e�r�4�r�r�i�r�iat air�Y�e�Y�rs Y, t& dr�r�tr�, rt�eie�e�kdeir�r�r�ir�rztir�ira�k *tsYs4�r�Y•fta4 &�k�tsYaYdr�¢�rdr APPLICATION APPROVED 134 �� ✓ X- e -2p of /,�r Plans Examiner (Revised 02 /08/06) Engineer Zoning 04/26/2013 15:36 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES Miami %Zpores a AV I V 1I1 Building Department 1('050 N.E.2nd Avt:nuc -,, Miami Shore,-;. Florida :33138 (30b) 705.2204 h :ax: ( 305) Ibfi.W72 April 26. 2013 Permit No: ELC1 ^.,793 JUN 07 00 Electrical Critique - Mi0hag6 L1pvanev 1. NEED SCOPE OF WORK AND COPY OF CONTRACT ?. PANEL SCHDULES ut-11 Y 3. IS NORTH MACHINE ROOM ONLY TO RECEIVED NE A/C? l�Oi71 /001 Plan review is riot complete, when all items above. are corrected, we will do a complete Ilan review. If any sheets are voided, remove them from the plans and replace with now revised sheets and include ono set of voided sheets in the ro.- submittal drawinq.5. Proposal No. 081612ts2 State License # 13001529 2369 W. 78h Street, Hialeah, FL. 33016 Customer: Location: The Shores Condo. The Shores Condo. 1700 NE 105 St. 1700 NE 105 St. Miami Shores, FL. 33138 Miami Shores, FL. 33138 Attn: Charlie Sammons Re: Two (2) Car Elevator Remodel Ph: 305-891-8891 a La Dm Fax: 305- 891 -0590 (;5 im b� �a� Description of work or service: 1. We have included fumishing and installing: a. Main line safety switch with rejection Gips and RK5 fuse. (Size of disconnect is based on exsting Motor sizes) b. New cab car light safety switches. c. Code compliance machine room light fixtures with protective covers d. GFI receptacles In machine room. e. GFI receptacles in eacti'pit: f. New hoist way lights in each pit. g. Phone Conduit with wire only h. Dedicated earth grounds per elevator machine room I. Air Condition connection for elevator designated for elevator on emergency generator j. Lowering relay contact for two (2) elevators k. Permit provided with this proposal (please allow 4 weeks after the owner information is submitted for permitting) I. Price is Base on re- using main line feeders. (Based on existing motor sizes) m. Proposal is base on information to us from the building any work beyond the scope of this proposal will have additional cost. 2. Not included in this proposal is the following: a. fire alarm b. shunt trip relays connected to the existing fire alarm c. Not responsible for eAsting code violation. 3. All work is to be done on regular working hours between 8:00 AM to 4:30 PM excluding holidays -and overtime. included is one (1) night shut down of elevators. Price for the work or service performed: Nine thousand eight hundred ninety seven Dollars and no Cent $ 9,897.00 Adder price for One (1) 1 ton mini splits A/C w /duct work from existing A/C duct $ 5,1.57.00 All additional work performed shall be paid for at the rate of $_83.04 per regular working hour. Additional materials used in the work shall be paid for at our normal rates. PAYMENT TERMS: C.O.D_CREDIT_ OTHER_X_ (SPECIFY BELOW) All payments shall be due in accordance with the terms described above. Customer agrees to pay all court costs and attorneys fees should legal means be necessary for collection. 30% due upon execution of contract, progress bill due at the time of invoiced. Balance due u 1, 0 Ir A ii 11 of work Due to thee current commodities market, BE ADVISE THIS PRICE WILL ONLY BE VALID OR A PERIOD OF FIVE (5) DAY We reserve the right to adjust this proposal to reflect market values. Submitted by, Troy Steggerda Project Manager Date: October 10, 2012 Accepted by, Ca IV 00 Customer^ Authorized Signa'15re&TI tle Date: t�/crl��rc / %�r w crrj�rc� »iu�� Phone: (305)805 -8166 Fax: (305) 805 -8190 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 April 26, 2013 Permit No: ELC13 -793 Electrical Critique — Michael Devaney 1. NEED SCOPE OF WORK AND COPY OF CONTRACT 2. PANEL SCHDULES 3. IS NORTH MACHINE ROOM ONLY TO RECEIVED NE A/C? Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. 04/26/2013 13:36 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES * * * * * * * * * * * * * * * * * * * ** * ** TX REPORT * ** TRANSMISSION OK TX /RX NO RECIPIENT ADDRESS DESTINATION ID ST. TIME TIME USE PAGES SENT RESULT Miami Shores Village Building Department ; 0050 N. E.2nd Avc.n.it: Mimmi hr. ?ret;;. Florida 3313£3 'Tol: (30,5) 79,i.:-?; 04. fax: (305) 776.8972 April 26. 2013 Permit No: ELC1$..793 3547 93058058190 04/26 15:36 00'36 1 OK Electrical Critique - Michael Devaney 1. NEED SCOPE OF WORK AND COPY OF CONTRACT 2. PANEL SCHDULES 3. IS NORTH MACHINE DOOM ONLY TO RECEIVED NE A /C? rhnn7 Detail by Entity Name Events No Name History Return to Search Results by Entity Name SHORES CONDOMINIUM, INC. iment Number :IN Number Filed or Country is Event t Date Filed t Effective Date 707621 591095398 07/21/1964 FL ACTIVE AMENDMENT 06/27/2012 NONE 700 NORTHEAST 105TH STREET MIAMI, FL 33138 ;hanged: 04/22/2000 Aalling Address 700 NORTHEAST 105TH STREET MIAMI, FL 33138 :hanged: 04/22/2000 iegistered Agent Name & Ad ARA & ASSOCIATES, PA 200 Brickell Avenue quite 1450 4IAMI, FL 33131 Jame Changed: 01/27/2012 ►ddress Changed: 03/31/2013 Micer/Director Detail lame & Address itle S ,TUBBS, PATRICIA 700 NE 105 ST #211 4IAMI SHORES, FL 33138 idle P Page 1 of 3 Entity Name Search http: // search. sunbiz. org / Inquiry/ CorporationSearch/ SearchResultDetail lEntityNameldomn... 4/17/2013 Detail by Entity Name ►AMMONS, CHARLES 700 NORTHEAST 105TH STREET 301 MIAMI, FL 33138 be VP ,WAN, ROBERTA 700 NE 105 ST #111 41AMI, FL 33138 [be VP IAJO, PEDRO 700 NE 105 ST #111 41AMI, FL 33138 IARQUEZ, ESTHER 700 NE 105 ST #417 IIAMI, FL 33138 Report Year Filed Date 2011 01/19/2011 2012 02/09/2012 2013 03/31/2013 03131/2013 --ANNUAL REPORT View image in PDF format View image in PDF format 06/27/2012 -- Amendment View image in PDF format 02/09/2012 -- ANNUAL REPORT View image in PDF format 01/27/2012 -- Reg. Agent Change 01/19/2011 --ANNUAL REPORT View image in PDF for 09/27/2010 -- Reg. Agent Change View image in PDF for 05/04/2010 -- ANNUAL REPORT View image in PDF for 1 011 412009 -- Reg. Agent Change View image in PDF format 06/15/2009 -- Reg. Agent Change View image in PDF for 04/30/2009 -- ANNUAL REPORT View image in PDF format 04/25/2008 --ANNUAL REPORT View image in PDF for 09/1812007 -- Reg. Agent Change View image in PDF format 04/27/2007 -- ANNUAL REPORT View image in PDF format 05/01/2006 --ANNUAL REPORT View image in PDF format 05/04/2005 -- ANNUAL REPORT View image in PDF format 04/19/2004 -- ANNUAL REPORT View image in PDF format 04/28/2003 -- ANNUAL REPORT View image in PDF format 01/2512002-- ANNUAL REPORT View image in PDF format 05/14/2001 --ANNUAL REPORT View image in PDF format Page 2 of 3 http: // search. sunbiz. org / Inquiry/ CorporationSearch/ SearchResultDetail lEntityNameldomn... 4/17/2013 Detail by Entity Name 04/22/2000 -- ANNUAL REPORT View image in PDF format 02/26/1999 -- ANNUAL REPORT View image in PDF format 04/14/1998 --ANNUAL REPORT View image in PDF format 03/04/1997 -- ANNUAL REPORT View image in PDF format ome n c s Searches 03/18/1996 -- ANNUAL REPORT View image in PDF format 06/14/1995 -- ANNUAL REPORT F View image in PDF for Evens No Name History Return to Search Resuits f • ii_ ■_.e 1 Cppyrigh C and Privacy Policies State of Florida, Department of State Forms Page 3 of 3 Help Entity Name Search http: // search. sunbiz. org / Inquiry/ CorporationSearch/ SearchResultDetail lEntityNameldomn... 4/17/2013 4 PLANS PREPAIR BY: AUSTEN ENT Austen E16dtric Inc. & R ISES INC. s nAirconditioning Inc. 2369 W ST 8th STREET i (� HIAL H 33016 Offi Fad EC 13001529 JC SHAWN CR EC 13004175 RICHARD A. RRY CAC 1814568 JAMES R. T RASHER • If � y � Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS fv1Q4. PROJECT NAME The Shores Condo. 1700 NE 105th Street MIAMI FL, 33138 CONDENSER AIR HANDLER MFG: MITSUBISHI MGF : MITSUBISHI MUYGE12NA MSYGE12NA BTU: 12,000 NO HEAT MAX BREAKER :15 AMP MAX BREAKER: 15 AMP COPPER LINES CFM : 650 3/8 & 1/4 SEER 17 i V 650 CFM NOTE: 1. FASTEN UNIT TO MOUNTING ANGLE USING 4 -5/16" BOLT WITH NUTS AND WASHERS THROUGH HOLES IN MANUFACTURER PROVIDED MOUNTING FEET AND ANGLES LOCATED APPROXIMATELY AS SHOWN. 2. ATTACH RACK TO WALL USING A MINIMUM OF 7 - 3/8"x 3" TAPCONS WITH 1 -3/4 MINIMUM EMBEDMENT INTO MASONRY WALL APPROXIMATELY AS SHOWN. CONDENSER AND STAND BY MITSUBISHI North Machine room r•- S S AIR HANDLER N.T.S. 3/4 PVC DRAIN TO GARDEN AREA CONDENSOR LOCATED ON GROUND FLOOR ON MITSUBISHI STAND UCT SCHEDULE /A PEN RETURN HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR X FIRE DAMPER X SMOKE DAMPER X FIRE RATED ROOF / FLOOR X FIRE RATED ENCLOSER X FIRE STOPPING X SMOKE CONTROL Ix NO HEAT LOAD REQUIRED SEE CHAPTER 13 FBC SEC. 13.101.5.7 ELECTRICAL EQUIPMENT SWITCHING BUILDING WHICH PROVIDE SPACE CONDITIONING FOR EQUIPMENT ONLY IN WHICH NO OPERATOR WORKS ON A REGULAR BASIS. OF 1. INSTALL (1 ) TON MINI SPLIT SYSTEM IN ELEVATOR MACHINE ROOM. n � � W C CL o z _w = AUSTEN A/C INC. 2369 WEST 78 STREET HIALEAH FL.33016 305- 805 -8166 305 - 805 -8190 FAX CAC 1814568 The Shores Condo 1700 NE 105th Street MIAMI FL, 33138 [NTS M -1 POWER RISER DIAGRAM N.T.S. To Elevator Equipment by others �e --a-- a -- - -- 1-1/2'C II 3# 3 �� - _ -._ -� - -- NEW13VOTHERS- 1 # 8GND 100 "12\ 380 250V fl= 20 30 1/2'C 3 # 12 THHN EXISTING 3# 3 I# 8GND EXISTING TO REMAIN REUSED EXISTING . CIRCUIT SUMP (� JELLY JAR WP JELLY JAR WP PIT / MACHINE ROOM LIGHTING: TO MEET CODE STANDARD ,FIXTURE SHOWN ARE DIAGRAMATIC ONLY QTY & LOCATIONS CHANGE AS NECESSARY TO MEET ELEVATOR CODE ASME A17.1 WP 2 X 32 W T -12 6M - 9' Wrap Around (xGFCI 7'T A/C RISER MINI SPLIT DIAGRAM NTS AHU MACHINE ROOM MACHINE ROOM INSIDE OUTSIDE FACTORY ACCEMBLE WIRE HARNESS JB 30 NF 1/YC 3 -#12 30 HOUSE PANEL 1 5 112'C 3 # 12 THHN 1/2'C 3 - #12 TYPICAL MACHINE ROOM LAYOUT N.T.S. PIT / MACHINE ROOM LIGHTING: TO MEET CODE STANDARD ,FIXTURE SHOWN ARE DIAGRAMATIC ONLY QTY & LOCATIONS CHANGE AS NECESSARY TO MEET ELEVATOR CODE ASME A17.1 GFCIAM FEN AM DRAIN SINGLE CAB ELEV. PIT NTS North Machine room NATIONAL ELECTRIC CODE 2008 WP GFCI ACU N W+E S — — BY OTHERS REUSE EXISTING NEW / REPLACE SCOPE OF WORK 1. REPAIR / REPLACE (1) MAIN LINE SAFETY SWITCH. 2. REPAIR / REPLACE (1) CAB CAR SAFETY SWITCH. 3. REPLACE (1) GFCI IN PIT ROOM. 4. REPLACE (1) GFCI IN ELEVATOR ROOM. S. REPLACE LIGHTS IN PR ROOM. 6. REPLACE LIGHTS IN MACHINE ROOM. 7. AC CONNECTION AUSTEN ELECTRIC INC. 2369 WEST 78 STREET HIALEAH FL. 33016 305 - 805 -8166 305 - 805 -8190 FAX EC 13001529 EC 13004175 The Shores Condo. 1700 NE 105th Street MIAMI FL, 33138 NTS Q-1 0 TO Elevato POWER RISER DIAGRAM N.T.S. by others 'p1-- NEWBYOTHER3 pU 9 E 30 /2' C 3 # 12 THHN EXISTING TO REMAIN REUSED EXISTING CIRCUIT SUMP (�. m JELLY JAR WP JELLY JAR WP PIT / MACHINE ROOM LIGHTING: TO MEET CODE STANDARD ,FIXTURE SHOWN ARE DIAGRAMATIC ONLY QTY & LOCATIONS CHANGE AS NECESSARY TO MEET ELEVATOR CODE ASME A17.1 WP 2 X 32 W T -12 60-L - Ir Wrap Amu d GFCI (0s SINGLE CAB ELEV. PIT NTS NATIONAL ELECTRIC CODE 2008 N W +E S TYPICAL MACHINE ROOM LAYOUT N.T.S. PIT / MACHINE ROOM LIGHTING: TO MEET CODE STANDARD ,FIXTURE SHOWN ARE DIAGRAMATIC ONLY QTY & LOCATIONS CHANGE AS NECESSARY TO MEET ELEVATOR CODE ASME A17.1 EPA GFCI SOUTH MACHINE ROOM JBOX — — BY OTHERS REUSE EXISTING NEW / REPLACE SCOPE OF WORK I. REPAIR I REPLACE (2) MAIN LINE SAFETY SWITCH. 2. REPAIR / REPLACE (2) CAB CAR SAFETY SWITCH. 3. REPLACE (1) GFCI N PIT ROOM. 4. REPLACE (1) GFCI N ELEVATOR ROOM. 5. REPLACE LIGHTS N PIT ROOM. 6. REPLACE LIGHTS IN MACHINE ROOM. 7. AC CONNECTION a o 0) LL o m Gw.M � •Q o =cEa atE cc.) � G3 a. � 0 AUSTEN ELECTRIC INC. 2369 WEST 78 STREET HIALEAH FL. 33016 305 - 805 -8166 305 - 805 -8190 FAX EC 13001529 EC 13004175 The Shores Condo 1700 NE 105th Street MIAMI FL, 331W NTS E-2 ti 1-1/2"C 3# 4 1 # 8 GND 0 1 00 3 80 250V 30 EXISTING 1 -1/2'C 3# 3 :i:t I# 8 GND 'p1-- NEWBYOTHER3 pU 9 E 30 /2' C 3 # 12 THHN EXISTING TO REMAIN REUSED EXISTING CIRCUIT SUMP (�. m JELLY JAR WP JELLY JAR WP PIT / MACHINE ROOM LIGHTING: TO MEET CODE STANDARD ,FIXTURE SHOWN ARE DIAGRAMATIC ONLY QTY & LOCATIONS CHANGE AS NECESSARY TO MEET ELEVATOR CODE ASME A17.1 WP 2 X 32 W T -12 60-L - Ir Wrap Amu d GFCI (0s SINGLE CAB ELEV. PIT NTS NATIONAL ELECTRIC CODE 2008 N W +E S TYPICAL MACHINE ROOM LAYOUT N.T.S. PIT / MACHINE ROOM LIGHTING: TO MEET CODE STANDARD ,FIXTURE SHOWN ARE DIAGRAMATIC ONLY QTY & LOCATIONS CHANGE AS NECESSARY TO MEET ELEVATOR CODE ASME A17.1 EPA GFCI SOUTH MACHINE ROOM JBOX — — BY OTHERS REUSE EXISTING NEW / REPLACE SCOPE OF WORK I. REPAIR I REPLACE (2) MAIN LINE SAFETY SWITCH. 2. REPAIR / REPLACE (2) CAB CAR SAFETY SWITCH. 3. REPLACE (1) GFCI N PIT ROOM. 4. REPLACE (1) GFCI N ELEVATOR ROOM. 5. REPLACE LIGHTS N PIT ROOM. 6. REPLACE LIGHTS IN MACHINE ROOM. 7. AC CONNECTION a o 0) LL o m Gw.M � •Q o =cEa atE cc.) � G3 a. � 0 AUSTEN ELECTRIC INC. 2369 WEST 78 STREET HIALEAH FL. 33016 305 - 805 -8166 305 - 805 -8190 FAX EC 13001529 EC 13004175 The Shores Condo 1700 NE 105th Street MIAMI FL, 331W NTS E-2 ti X X � �--� � � .. i Itt�1l ttllt litlt itllt 11t1t l�ti� ttllt II!! C.!E'N 2013RO292203 OR Bk 28581 fps 48141 (iias ) NOTICE OF COMMENCEMENT HARVEY RUVINP C ERK OFQCOURT IIZAi1i -DADS COUNTY9 FLORIDA A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION LAST PAGE. PERMIT NO. . TAX FOLIO NO. `I_0 ID _62�0 — ®p0 6 STATE OF FLORIDA COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. This Notice of Commencement should be recorded at: The Clerk of Courts Miami -Dade County Recorder Courthouse East, 22 NW First Street, 1st Floor, Miami, FL 33128 1. Legal description of property and streettaddress: ®AGO �� f(�5�• //�lriry+.t �� 2 Description of Improvement �t�eefar /��1(2S 3.Owner(s) name and address: i /-7(00 /NJ 4 10,. interest in property: Name and address of fee simple titleholder: M 4. Contractor's name and address: U� - F�C� 6z✓� 'i 4 L 280 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: �f 7. Persons with the state of Florida designated by Owner upon whom no or other documents may be served as provided by Section 713.13(1) (a) 7, Floridtrt es. Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provide in Section 713.13(1) (b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the different date is specified) Signature of Owner Print Owner's Name 6 / / '',ti •�.�r ^z, D , -& Fx -�2<<� � Pared by Sworn to and subscribed before me this day of Notary Public Print Notary's Name My commission expires: 2d 1 ?> ao+ " Notary PUWC $t9te of FWW. �� Josephine Treber MY Commission EE08Wj o►ao Eg1rn 05 /?0/2pf8 (Seal) X A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NOP -2- ' _002 d STATE OF FLORIDA COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Fiorida Statutes, the following information is provided in this Notice of Commencement. This Notice of Commencement should be recorded at: The Clerk of Courts Miaml -Dade County Recorder Courthouse East, 22 NW First Street, 1st Floor, Merril, FL 33128 1. Legal description of property and streettaddress: / 7 (0 0 X0.) h�;7_ f 0 ! "_ ST. 2. Description of improvement: 2'ri OR Bk 28581 Pa 48131 (1pa ) RECORDED 04/15/2813 14 .*26:53 HARVEY RUVINP CLERK OF COURT MIMI -DADE COUNTYP FLORIDA LAST PAGE � t Ft vr/t i � �� i• 3 � f � 3.Owner(s) name and address: 7` e, i- %V D -`� �� ol Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and aC dress: r a. 4, r _Z — , --, �5:3C)14- 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address ' I/A 5UM 7. Persons with the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1) (a) 7, Florida State Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Name and address: -mom 9. Expiration date of this Notice of Commencement: (the different date is specified) d Print Owner's Name Swom to and subscribed before me this day of Notary Public Print Notary's My commission ex�j/s: ,�N- Q0 by GERM R Notary Public - State of Florida My Comm. Expires Jan 25, 2015 Commission 0 EE 31688 Bonded Through National Notary Assn. (Seal)