Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-13-2149
Inspection Worksheet Miami Shores Village 0 . 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 199695 Permit Number: RF -9 -13 -2149 Scheduled Inspection Date: November 07, 2013 Inspector: Rodriguez, Jorge Owner: RICHARDS, RANDALL Job Address: 10666 NE 11 Avenue Miami Shores, FL Project: <NONE> Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number (305)335 -4848 Parcel Number 1122320280690 Contractor: A STAR CONTRACTORS INC Phone: 954- 922 -5990 Building Department Comments NEW CONSTRUCTION TILE ROOF INSPECTOR COMMENTS False November 06, 2013 For Inspections please call: (305)762 -4949 Page 15 of 40 Inspector Comments Passed b Failed Correction Needed ❑ Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. November 06, 2013 For Inspections please call: (305)762 -4949 Page 15 of 40 Lab Report No. 121919 F Providing Solutions to the Roofing Industry C.A. #: 26095 Lab Certificate: 09- 0715.02 4 ` CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106 PROPERTYADDRESS: 10666 NE 11`' Ave., Miami Shores PERMITNo: OWNER ROOFING SQUARES• 2 CONTRACTOR: A Star Contractors ROOF PffcH.• 3:12 TTLE TYPE.- Flat .INSPECTOR INITIALS: JM ATTACHMENT:- Polyfoam TEST DATE: 10/22113 Toe #inn lZm6nmanf• ninifal r hnfillnn f1FIC 9f n Tac4Tnhidufinn Rani airad Tasfinn Fn No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT 1 -3 Passed THIS ROOF HAS: PASSED N I FAILED I I THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI -DADE COUNTY TAS 106. R wed by: e, i3 Alberto Cardona, P.E. -Lic #17138 10735 SW 216'h St. Tel: (305) 256 -4550 Unit 416 Miami, FL 33170 www.floridatec.net Fax (305) 256 -6833 Lab Report No. 121919 FLORIDA 76, C Providing Solutions to the Roofing Industry C.A. #: 26095 x Lab Certificate: 09- 0715.02 CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106 PROPERTYADDRESS: 10666 NE 11th Ave., Miami Shores PERMIT No. OWNER CONTRACTOR A Star Contractors TILETYPE.• Flat ATTACHMENT.- Polyfoam Jim Fmjinmanf- ninifal rhnfillnn i1FIR qnn Tpc/Tah►datinn ROOFING SQUARES:- 2 ROOF PffcH. 3:12 INSPECTOR INITIALS: 3M TEST DATE. 10%22113 Ranuirad Tasfinn Fnrr No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT 1 -3 Passed THIS ROOF HAS: PASSED IXI FAILEDI I THE STATIC TIPT,TFT IN ACCORDANCE WITH MIAMI -DADF, COT JNTY TAS 106. V1 ed by: Alberto Cardona, P.E. -Lic #17138 10735 SW 216'` St. Tel: (305) 256 -4550 Unit 416 Miami, FL 33170 www.floridatec.net Fax (305) 256 -6833 I !I 11 �' 195 S. Andrews Ave., I Zrn. A -100, Ft. Lauderdale, FL 33301 -1895 — 954 - 831 -4000 - -- �jl I :, VALID OCtOBER 1, 2013 THROUGH SEPTEMBER 30, 2014 ' I , r DBA: A� STAR CON'T CTORS XXC RECBipfi #:ROOFIM814tET METAL BU mess Name: Business Type: ( R00k ZNG CONTRACTOR) Owner Name: m&Ri< eamp-RoN Business Opened: o3 /19/1999 'Business Location., 7314 HAYES :IT State /County /Cert/Reg :CCC057736 HOLLYWOOD Exemption Code: Business Phone, 9 54 - 92 2 - 5 9 0*( I • ;,; I' Rooms Seat �. 'Empfoys®s .. Machines Prof�essiott8�a For Vorrtling aulsHess Ony Number of MaChina s_ ..,�:• - •� 11A Tax Amount Transfer Fuse N F Fee Penalty Prior Years 0011eatlon Cost Total Paid ``.0:'0,`0. ' t'!;.:. :0:•i3d b.00 27.00 . .I i j THIS RECEIPT MUST BE I IOSTED CONSPICUOUSLY I'N YOUR PLACE OF. BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non - regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements, This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location, This receipt does not indicate that the business is legal or that I'; •; it is In compliance with State 'or local Iaws and regulations. Address: CAMERON FAXES STREET WOOD, FL 33020 2013 .2014 i r f e, 6 Receipt: #01A -12- 00010932 Paid 08/01/203.3 27.00 l k Miami Shores Village � . g SEP 23 2013 p P Building Department Bx: 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: 305 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 20 BUILDING Permit No. _ r. _ PERMIT APPLICATION Master Permit No._ J 3 ��- Permit Type: BUILDING ROOFING JOB ADDRESS: V (9 IV City: Miami Shores County: Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: 3 „ OWNER: Name (Fee Simple Titleholder): P-qz"— ° f C'l� phone#: k' _ `H,', Address: ��� ' L City: lv ` `1 State• Zip: �- 1 Tenantl lessee Name: Phone #: Email: �j , YV\-V'-, ' CONTRACTOR: Company Name: Phone #: Address- 4 S 5 City : State: Zip: fier Name: f3 Phone #: tell, to Certification or Registration #: U Certificate of Competency #: ntact Phone #: Email Address: IGNER: Architect/Engineer: Phone#: �U` ue of Work for this Permit: $ Square/Linear Footage of Work: of Work: ddition OAlteration ONew ORepair/Replace ODemolition criptign of Work: — ��� qQ �O.atC.iOliae`\ Color thru.file: Wp Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ L CCF $ CO /CC $ _ DBPR $ Bond $ ® Technology Fee $ TOTAL FEE NOW DUE $ 4u 1 143 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip 1 4 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDMONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in go faith that a copy of the notice of commencement and construction lien law br re will be delivered to the person whose pr erty i subject to attachment. Also, a certified copy of the recorded notice of comet ment must be posted at the job site for the rst ins ction which occurs seven (7) days after the building permit is issue . In absence of such posted notice, the inspec on will n t be approve d and LJ ' a inspection fee will c rged Signature \4 Signature wner or Agent Contractor The fo a' gin tru t was ac owledged b fore e s The foregoing instrument was acknowledged before me this day of by day of , 20 3, by mod, h_o i pe sonally known to me "wwh has produced is personally known to or who has produced ` /G111C� As identification and who did take as identification and who did take an oaj� PUBLIC: -- SignA IIVUUUV Print: My Commission Expires: APPROVED BY C�8 \� �QS ida k �10 \P� State of E10 Zz1 5) 9,10 c (es Sep 6810 E,9 12 e, Shcoo® Plans Examiner Structural Review (Revised 3 /12/2012)(Revised 07 110 /07)(Revised 06 /10/2009)(Revised 3/15/09) NOTARY PUBLIC: Sign: K.t -'^ Print: 1 61 R My Commission Expires /l Zoning Clerk EN i;` i�: [ •. CERTIFICATE OF LIABILITY INSURANCE DATE (MM/OD/YYYY) 03/27/2013 01:34 PM THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDEN. IMPORTANT: if the cerficate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement.' a statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Hi 55 Da hpgnt Risk Services LLC 1 LBJ Freeway, Suite 1200 las, X•75240 CONTACT NAME: PRONE t� No � (800) 728 -0523 VAX (AA Nor. (972) 404 -0380 EaoDREas, INSURED AFFORDING COVERAGE NAIC S INSURER A: Companion Property and Casualty insurance company 12157 INSURED: A- 231:4 HO Ph Aspen Staff Leasing, Inc. 1 /c /f: TAR CONTRACTORS, INC. HAYESjT LYWOOD, FL 33020 ne: (954) 922 -5990 Fax: (954) 922 -5486 I INSURER B: INSURER C: EACH OCCURRENCE INSURER D: INSURER E: ? INSURER F. COVERAGES CERTIFICATE NUMBER! AC13- 62400007- 1179291 REVISION NUMBER: I 11-Y NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSR SUSR WVD POLICY NUMBER POLICY EFF DATE M/DD pp EXP DATE D LIMITS AUTHR OED REPRESENTATIVE GENERAL LIABILITY EACH OCCURRENCE $ COMMERCIAL GENERAL LIABILITY DAMAGE To RENTED $ CLAIMS MADE ❑ OCCUR ❑ ❑ MED EXP (Any one person) $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ EN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP /gP AGG POLICY M Pp&- LOC AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT ANY AYT0 (Ea accident) $ ALL OWNED AUTOS k3QUILY INJURY (Per person BODILY INURY (Per accident) $ SCHE ULED AUTOS ❑ ❑ PROPERTY DAMAGE (Per accident) $, HIRED�4UTOS NON-OWNED AUTOS UMBRELLA UAB CWMS MADE EACH OCCURRENCE $ EXCESS LIAB OCCUR ❑ El AGGREGATE $ DEDUCTIBLE $ RETENTION $ $ A EMPLOYERS' LIABILITY ANY PROPERIETOMXECU11VE YIN OFFICERAEMBER EXCLUDED? O (Mandatory in NH) N/A ❑ DPE26272740360 04/01/2013 04/01/2014 X I T E.L EACH ACCIDENT $. 1000000 E.L. DISEASE - EA EMPLOYEE $ 1000000 If yes, describe under SPECIAL PROVISION below E.L. DISEASE - POLICY LIMIT $ 1000000 0 T I I I DES 1. Leasing, $t RIPTION OF OPERATIONS /LOCATIONS/VEHICLES(Attached ACORD101, Additional Remarks Schedule, H more space is r"Wred This certificate remains in effect, provided the client's account is in good standing with Aspen Staff Inc.. Coverage is not provided for any employee for which the client is not reporting wages to Aspen ff Leasing, Inc.. Applies to 100% of the employees of Aspen Staff Leasing, Inc. leased to A -STAR CO TRACTORS, INC., effective 04/01/2013 2. Insured is afforded Workers Compensation & Employers liability &s a co- employer under the policy for employees leased from Aspen Staff Leasing, Inc.. CE TIFICA E HOLDER 's%1Llro3 =I Ijr! I 11IT41I1k I At %inu LO (ZUI WUD) W 19$3 -ZU1U AGURD GUHPUF7ATIUN. All ngnI reserves. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE . EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH CITY OF MIAMI SHORES BUILDING DEPARTMENT THE POLICY PROVISIONS. 10050 NE 2ND AVE MIAMI SHORES, FL 331382304 AUTHR OED REPRESENTATIVE At %inu LO (ZUI WUD) W 19$3 -ZU1U AGURD GUHPUF7ATIUN. All ngnI reserves. i ASTAR -1 OP ID: EwN CERTIFICATE OP LIABILITY INSURANCE DATE(MM /DD/YYYY) 08/30/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS . CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Phone: 813 -963 -1669 nciA°MACT MORROW INSURANCE GROUP MORROW INSURANCE GROUP L NO C. OLNEY/A196064 Fax: 813 - 961 -3743 AICONN Ext : 813- 963 -1669 A C No : 813- 961 -3743 T 936 N RTH LE MABRY HIGHWAY aooREsS: EILEEN MORROWINSURANCE.NET �T' MPA, FL'.33 VID' ERNAN CZ INSURER(S) AFFORDING COVERAGE NAIC # INSURER A: CANAL INDEMNITY COMPANY 27790 N URED A -STAR CONTRACTORS, INC. INSURER B: AMERICAN STATES INS CO 19704 23 4 HAYES ST INSURER C: PRINCETON EXCESS & SURPLUS HOLLYWOOD, FL 33020 INSURER D: INSURER E: INSURER F: t+V YGrvw CJ UtK I It-IUA I E NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, ' EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE L UB POLICY NUMBER POLICY M/DD/YYYY POLICY EXP LIMITS A {! GENERAL LIABILITY X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE OCCUR X CONTRACTUAL LIAB GL106075 09105/2013 09/05/2014 EACH OCCURRENCE $ 1,000,00 PREMISES Ea occurrence $ 50,00 MED EXP (Any one person) $ 5,00 PERSONAL & ADV INJURY $ 1,000,00 GENERAL AGGREGATE $ 2,000,00 GE L AGGREGATE LIMIT APPLIES PER: PRO - POLICY e LOC PRODUCTS - COMP /OP AGG $ 2,000,00 $ Ilili y; I, AUT MOBILE IIABILITY ANY AUTO ALL OWNE D (—� SCHEDULED AUTOS X ' AUTOS NON -OWNED HIREDAU OS XI AUTOS PIP FL X STATUTORY 01 C138682640 07/10/2013 07/10/2014 COMBINED SINGLE LIMIT Ea accident 1,000,000 $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ X PROPERTY DAMAGE Per accident $ X PIP -BASIC $ 10,00 C UMBRELLA LIAB EXCESS LIAB X OCCUR CLAIMS -MADE RXSLAW000104-02 09 /05/2013 09/0512014 EACH OCCURRENCE $ 2,000,00 X AGGREGATE $ 2,000,00 DED 1 X I RETENTION $ 0 $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory in NH) i If yes, describe under ' DESCRIPTION OF OPERATIONS below NIA WCSTATU- OTH- I IT R E.L. EACH ACCIDENT $ E.L. DISEASE -EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ QE$GRIPTI Iii � Iljl s N OF OPERATIONS 1 LOCATIONS i VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If more space is required) II i ' CITYMIS SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE CITY OF MIAMI SHORES THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. BUILDING & ZONING DEPT FAX 305 - 756 -8972 AUTHORIZED REPRESENTATIVE 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 a., /�'t' • .� • ©1988 -2010 ACORD CORPORATION. All rights reserved. I ACORD 25 (2010105) The ACORD name and logo are registered marks of ACORD If C #620353 DEP 6 T STATE OF FLORIDA The ROOFING CONTRACTOR Named below IS CERTIFIED '+ Under the provis©ris of Chaptf, V' Expiration date: AUG 31, 2014 �. t - CAMERON . . A= STAR CON�C.TOR$ 3625 N COUNTRY CLUB -DR' AVENTURA FL.33020 RICK SCOTT GOVERNOR DISPLAY AS REQUIRED BY LAW g CITY OF HOLLYWOOD LOCAL BUSINESS TAX RECEIPT KEN LAWSON SECRETARY I I PRINT DA THIS IS YOUR LOCAL BUSINESS TAX RECEFT. PLEASE DETACH AND POST IN A CONSP PLACE AT THE BUSINESS LOCATION. PLEASE DO NOT REMIT ANY PAYMENT. THIS IS N Business Name: Business Location: Business Class: Tax Basis: Receipt Number: Receipt Year: Expiration Dater A -STAR CONTRACTORS, INC. 2314 HAYES ST CONTRACTOR /ROOFING 1 WORKER (OWNER) 13 00038863 10/01/12 09/30/13 NEW CHARGES: (itemized Below) 190.00 Comments: Base Fee 190.00 Additional Charges: 9 2r /jld MLL ,. TOTAL NEW CHARGES- 190.00 Penalty Amount: .00 Previous Balance Due: .00 TOTAL AMOUNT PAID 190.00 PURSUANT TO STATE LAW, THE LOCAL BUSINESS TAX IS LEVIED ON THE PRIVI EC. DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON - REGULATORY IN Al ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD Q E,, MEAN THAT THE CITY HAS DETERMINED THAT THE EXISTING OR PROPOSED SE', LOCATION IS LAWFUL. ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT D ES'I LEGALIZE OR CONDONE THE NATURE OF THE BUSINESS BEING CONDUCTE CONTRARY TO ANY LOCAL, STATE OR FEDERAL LAWS OR REGULATIONS. �N I it 117 0.7/13/2012 2012 .127001501 CC057?3 i ; m s�•x s... °P. ^:: '', The ROOFING CONTRACTOR Named below IS CERTIFIED '+ Under the provis©ris of Chaptf, V' Expiration date: AUG 31, 2014 �. t - CAMERON . . A= STAR CON�C.TOR$ 3625 N COUNTRY CLUB -DR' AVENTURA FL.33020 RICK SCOTT GOVERNOR DISPLAY AS REQUIRED BY LAW g CITY OF HOLLYWOOD LOCAL BUSINESS TAX RECEIPT KEN LAWSON SECRETARY I I PRINT DA THIS IS YOUR LOCAL BUSINESS TAX RECEFT. PLEASE DETACH AND POST IN A CONSP PLACE AT THE BUSINESS LOCATION. PLEASE DO NOT REMIT ANY PAYMENT. THIS IS N Business Name: Business Location: Business Class: Tax Basis: Receipt Number: Receipt Year: Expiration Dater A -STAR CONTRACTORS, INC. 2314 HAYES ST CONTRACTOR /ROOFING 1 WORKER (OWNER) 13 00038863 10/01/12 09/30/13 NEW CHARGES: (itemized Below) 190.00 Comments: Base Fee 190.00 Additional Charges: 9 2r /jld MLL ,. TOTAL NEW CHARGES- 190.00 Penalty Amount: .00 Previous Balance Due: .00 TOTAL AMOUNT PAID 190.00 PURSUANT TO STATE LAW, THE LOCAL BUSINESS TAX IS LEVIED ON THE PRIVI EC. DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON - REGULATORY IN Al ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD Q E,, MEAN THAT THE CITY HAS DETERMINED THAT THE EXISTING OR PROPOSED SE', LOCATION IS LAWFUL. ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT D ES'I LEGALIZE OR CONDONE THE NATURE OF THE BUSINESS BEING CONDUCTE CONTRARY TO ANY LOCAL, STATE OR FEDERAL LAWS OR REGULATIONS. �N I it 117 c,vp 2 Z�1 Code Edition 2010 HIGH - VELOCITY HURRICANE ZONES Section A/ (General Information) Lf tj Master Permit No. �� '�`'I Process No. Contractor's Name Job Address b �� /eE 1 �l ya t16 P ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ,W100mortar /Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ew Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. include dimensions of sections and levels. clearly urentny mmenslons of elevated pressure zones and location of parapets. 2010 FLORIDA BUILDING CODE — RESIDENTIAL AA o+ ;® F 10 a a o u e...� �. ro CL { L) L rte' •i.. � u D ® O O- 0 z (ice O o C'3 B m (D Cn AA o+ t Z HIGH - VELOCITY HURRICANE ZONES Florida Building Code Edition 2010 High Velocfty Hurricane Zone Uniform Pennit Applicadon Form. Section D (Steel) Sloped Roof System) Roof System Manufacturer: 4'w An IllProduct Approval Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1 • P2• 123• Maximum Design Pressure Product Approval Specific System: Method of tile attachment: Roof Slope: 2—:12 Steep Sloped Roof System Description Deck Type: �ype Und6fayff Insulation Fire Ridge Ventilation? Mean Roof Height: 2010 FLORIDA BUILDING CODE —RESIDENTIAL Ca r/ Rip Covering: % 40� & Size Drip �Type ge. i "A 44.23 HIGH- VELOCITY HURRICANE ZONES Piorida Building Code Edition 2010 High Veloft Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compared the values for Mrwith the values from Mf. If the Mr values are greater than or equal to the Mr values, for each area of the roof, then the file attachment method is acceptable Method I "Moment Based Tile Calcu ti s Per RAS 127" 34� _ -J- Md =m rl Product Approval Mr 1/0d .33� - - M; JE = Mt Product Approval M, V e (P3 4, x X - o - MQ 'M roduct Approval M; Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval n Mr Required Moment Resistance` Mean Roof Height Roof Slope 15 20' 26' 30' 40' 2:12 34.4 36.6 38.2 38.7 42.2 3:12 32.2 34A 36.0 37.4 39.8 4:12 30A 32.2 33.8 36.1 37.3 6:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29A 30.6 32.4 7:12 24.4 26.9 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "TJplift Based Tile Calculations Per RAS 127" w: = _) - W: _ x cos 8. = Fri: F (P2: ,- x 1: _ - _ x W: _ ._) - W: _ x Cos & -_ = Fr2: F (P3:_x1:_ =!x w: =` )- W :_xcos0.•_= Fri: F Where to Obtain Information Descriplion Symbol Where to find Design Pressure Pl or P2 or P3 RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height 11 Job site Roof Slope B Job Site Aerodynamic Multi lier A Product A Restoring Moment due to Gravity M Product Alpmal AttacrimentResistence Mt Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F Product val Required Uplift Resistance F Calculated Average Tile Wei t. W Product Approval Tile Dimensions 1= length W. Width I Product Approval All calculations must be submitted to the Building Official at the time of permit application. 44.24 2010 FLORIDA BUILDING CODE -RESIDENTIAL SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. _ Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. P.. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renail d in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removin the existing roof system). 3. Al Common roofs: Common roofs are those which have no visible delineation between neighboring units .e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner uld notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can e viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appea 5. Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. " Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not ove ded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the i e or of the structure assembly (the building itself). The existing amounpofptfic ventilation shall not be red d. It may be beneficial to consider additional venting which r u in extending the service life of the rr of r,. 9 Owner /Agent's Signature Date Contract Sig to _ to Revised on 7/9/2009 LD SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 10- 0706.08 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 1218.14 Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 1 of 9 M11AM MIAMI -DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www.mianddade.aov /uera Hanson Roof Tile 1340 SW 34 Ave Deerfield Beach, FL. 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 10- 0706.08 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 1218.14 Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub - Category: Roofing Tiles Material: Concrete 1. SCOPE This is a new system using Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate, as manufactured by Hanson Roof Tile Inc. in Deerfield Beach, Florida and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Hanson Flat Tile 1= 17.25" TAS 112 Flat, interlocking, concrete tile equipped with two w =13" nail holes. For direct deck or battened nail -on, mortar or adhesive set applications. Hanson Slate 1= 17.25" TAS 112 Flat, interlocking, concrete tile equipped with two w= 13" nail holes. For direct deck or battened nail -on, mortar or adhesive set applications. Hanson Chalet Shake 1= 17.25" TAS 112 Flat, interlocking, concrete tile equipped with two w =13" nail holes. For direct deck or battened nail -on, mortar or adhesive set applications. Hanson Southern Shake 1= 17.25" TAS 112 Flat, interlocking, concrete tile equipped with two w = 13" nail holes. For direct deck or battened nail -on, mortar or adhesive set applications. Hanson Victorian Slate 1= 17.25" TAS 112 Flat, interlocking, concrete tile equipped with two w =13" nail holes. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at hips, w = varies rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. 2.1 PRODUCT DESCRIPTION 1. Deerfield Beach, FL. NOA No.: 12- 1218.14 Mi p4pe cot Expiration Date: 04/10/18 Approval Date: 03121/13 Page 2 of 9 2.2 SUBMITTED EVIDENCE: Test Men cy Test Identifier Test Name/Report Date IBA Consultants, Inc. 2381 -265 TAS 112 Feb. 2008 Redland Technologies 7161 -03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) The Center for Applied 94 -084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94 -060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 25- 7094 -2 Static Uplift Testing TAS 102 Oct. 1994 Engineering, Inc. (4" Headlap, Nails, Direct Deck, New Construction) The Center for Applied 25- 7094 -8 Static Uplift Testing TAS 102 Oct. 1994 Engineering, Inc. (4" Headlap, Nails, Battens) The Center for Applied 25- 7094 -5 Static Uplift Testing TAS 102 Oct. 1994 Engineering, Inc. (4" Headlap, Nails, Direct Deck, Recover/Reroof) The Center for Applied 25- 7183 -6 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik -Drive Screws, Direct Deck) The Center for Applied 25- 7183 -5 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik -Drive Screws, Battens) The Center for Applied 25- 7214 -1 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik -Drive Screw, Direct Deck) The Center for Applied 25- 7214 -5 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik -Drive Screw, Battens) Redland Technologies 7161 -03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Redland Technologies P0631 -01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied Project No. 307025 Wind Driven Rain TAS 100 Oct. 1994 Engineering, Inc. Test #MDC -77 Nutting Engineering 13343.1 Physical Properties TAS 112 Aug. 2006 Celotex Corporation Testing 520109 -1 Static Uplift Testing TAS 101 Dec. 1998 Service 520111 -4 Celotex Corporation Testing 520191 -1 Static Uplift Testing TAS 101 March 1999 Service Walker Engineering, Inc. Calculations Aerodynamic Multiplier May 2006 Walker Engineering, Inc. Calculations Restoring Moments May 2006 Walker Engineering, Inc. Evaluation Calculations 25 -7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25 -7496 April 1996 NOA No.: 12- 1218.14 Expiration Date: 04/10/18 Approval Date: 03/21113 Page 3 of 9 2.2 SUBMITTED EVIDENCE: Test Aaencv Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 3. LIMITATIONS Test Identifier Evaluation Calculations Evaluation Calculations Calculations Test Name/Report 25 -7584 25- 7804b -8 25- 78044 & 5 25- 7848 -6 25 -7183 Two Patty Adhesive Set System Date December 1996 March 1995 April 1999 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set rile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (lbf) Length -1 (ft) Width -w (ft) Hanson Flat Tile including Slate, 11.6 1.4375 1.08 Chalet Shake, Southern Shake, Shake, Southern Shake, and Victorian Slate and Victorian Slate Table 2: Aerodynamic Multipliers - I (ft) Tile A. (ft) 1 (ft3) Profile Batten Application �lrect Deck Applicatio Hanson Flat Tile including Slate, Chalet 0.304 0.330 Shake, Southern Shake, and Victorian Slate NOA No.: 12- 1218.14 MIAMMADECOUNTY Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 4 of 9 Table 3: Restoring Moments due to Gravity - M9 (ft -lbf) Tile 2 ":12" 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" or Profile 38.1 17.2 including Slate, Chalet Shake, 1 -10d Smooth or Screw Shank Nail 7.3 greater Hanson Battens Direct Battens Pirect attens Direct Battens Direct Battens Direct Battens Direct Flat Tile 51.7 Deck Deck 24.3 Deck 24.2 Deck 1 -10d Smooth or Screw Shank Nail Eave Clip) Deck 19.0 Deck including 7.53 8.25 7.46 .17 7.35 8.05 7.20 7.88 7.02 7.69 6.83 7.48 Slate, Installation with a 4" tile headlap and fasteners are located a min. of 2Y2" from head of tile. Chalet Shake, Southern Shake, and Victorian Slate Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Hanson Flat Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 including Slate, Chalet Shake, 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Southern Shake, and Victorian Slate 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails 50.3 65.5 48.3 Installation with a 4" tile headlap and fasteners are located a min. of 2Y2" from head of tile. NOA No.: 12- 1218.14 Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 5 of 9 Table 6: Attachment Resistance Expressed as a Moment Mf (ft -lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Minimum Attachment Resistance Hanson Flat Tile including Slate, Adhesive2 31.3 Chalet Shake, Southern Shake, and 3M 2- Component Foam Roof Tile Adhesive AH -160 Victorian Slate Slate, Chalet Shake, Southern Shake, and 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 13.9 grams. 3MTm 2-Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft -lbf) Tile for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Hanson Flat Tile including Slate, Resistance Hanson Flat Tile including 3M 2- Component Foam Roof Tile Adhesive AH -160 3M 2- Component Foam Roof Tile Adhesive AH -160 40.4 Slate, Chalet Shake, Southern Shake, and 6 Seespecific mortar manufacturers Notice of Acceptance Victorian Slate 4 Large paddy placement of 45 rams of 3M 2-Component Foam Roof Tile Adhesive AH -160. 5 Medium paddy placement of 24 rams of 3M 2-Component Foam Roof Tile Adhesive AH -160. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft -lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Hanson Flat Tile including Slate, Mortar Set6 39.0 Chalet Shake, Southern Shake, and Victorian Slate 6 Seespecific mortar manufacturers Notice of Acceptance NOA No.: 12- 1218.14 Me Coin Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 6 of 9 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". HANSON FLAT TILE INCLUDING SLATE, CHALET SHAKE, SOUTHERN SHAKE, AND VICTORIAN SLATE (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQmEMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12- 1218.14 Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 7 of 9 • • ••• • • 0000 ••• • • • • • • •• • • • • •• • AND /OR 0000. 0000.0 0 • 000 • • • • 0 • • • • • •• 0 • 0 • 0• • • • • 0 • 0000 000 • • HANSON FLAT TILE INCLUDING SLATE, CHALET SHAKE, SOUTHERN SHAKE, AND VICTORIAN SLATE (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQmEMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12- 1218.14 Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 7 of 9 PROFILE DRAWINGS NOA No.: 12- 1218.14 Expiration Date: 04/10118 Approval Date: 03/21/13 Page 8 of 9 SOUTHERN SHAKE VICTORIAN SLATE END OF THIS ACCEPTANCE NOA No.: 12-1218.14 MIAMI DARE Expiration Date: 04/10/18 Approval Date: 03/21/13 Page 9 of 9 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2- Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 0228.18 MIAtNi•DADECt7UNTY Expiration Date: 05/10/17 �® Approval Date: 05110/12 Page 1 of 7 N MIAMI -DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov /pera 3M Company 3M Center Building 0220- 05 -E-06 St. Paul, MN. 55144 -1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2- Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 0228.18 MIAtNi•DADECt7UNTY Expiration Date: 05/10/17 �® Approval Date: 05110/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Descriution Moisture Vapor Transmission ASTM E 96 Specifications ASTM D 2126 3MTM 2- Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1.. Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 APPROVED Results 1.61bs. /ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Fe 3.1 Perm / Inch +0.07% Volume Change @ -40'F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Aeency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 Trinity Engineering 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research histitute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LnuTATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F W 2 F'= MS NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0 (B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per file as determined at calibration. No other settings shall be approved. 6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic rile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profle Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34/ an N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles 1 #3 1 8 NOA No.: 12- 0228.18 M M� Expiration Date: 05/10/17 .. � i Approval Date: 05/10112 Page 4 of 7 LABELING: All 3MTM 2- Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE .PATTY NO through pWdc mart Paddy MyNd Toe) o 1 2)Turn olvmaupoftdwmP1 =adhm e112hr. 101n. EeueCaurte e UrtdedeYmazrt Fa�a EaweouraeMIT. EMClaure appnx 4 fame e 1)PhoxM"h who" to able" 17to 23 wW2A for VOceq� NOtamgh ieemnait egtaoeWeIncorttactwfth the p nth 2)Turn olvmaupoftdwmP1 =adhm e112hr. 701 hG FMM WW05edge0 COW 011a ThenhoA ftfla o UrtdedeYmazrt ° em n9 i m mowwtva Alu w8 mulaftmof DOW pvtUmovanmm mime PoiMupNm� ihodteteaveline. �geso�� Eana rJoare We60e Faeda NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY NO through plastic cement My @M* Tile) Nall through plastic cement Underlepnot Tr in. EmCmm a Fascia Emcoum EMCIM11 Drip edge Iwo, NOA No.:* 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 Nall through plastic cement ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Faddy (between file) P8* (underlie) IN,; 0501, , Single paddyy 3 In und rtile Tx3 in. Single paddy on 2 In. 4 In. under- ,"Me"t Single paddy In. X 7 11L medium on top of bile a ae paddy eon Fascia cDurasonly Nell through plastic cement rOV-3 In. x 3 in 4 Single Paddy an undarlament Single paddy '7% on top of the EaW Course Nall through plastic ce Undwisyment pn.x31n. Sin /glet 41n. 2 In. paddyy on undue layment Single paddy on top of lie Em Courie 00 Paddy an tie EM Closure 2 �,.. Xr.7,,. ,,d,,M sh F paddy am course only ascia END OF THIS ACCEPTANCE Single paddy under tie Single paddy between file 2 In. x 7 In. medium sin paddy am course only < Fade Weephall Eave closure , Drip edge NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA # 09- 0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 dADo �a11 Approval Date: 09/15/11 Page 1 of 8 f ROOFING COMPONENT APPROVAL Cateeory Roofing Sub - Category_ Underlayment Material: SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self - adhering, glass - Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber /polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof file underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13116 Approval Date: 09/15/11 Page 2 of 8 Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 65'8" x 3'33/8" waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefmic film on the upper surface for #2 use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick IR -Xe Roll: TAS 103 and A fine granular /sand top surface self - adhering, underlayment 65'x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 80 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32'10" x 3'3318" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A non - wicking fabric surfaced, self - adhering, underlayment 65' x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced (Facer of Membrane 80 mils thick with a high strength polyester fabric, bituminous with surface printing) sheet material for use an an underlayment in Manufacturing Location sloped roof assemblies. Designed as a metal #1 & #2 roofing and roof tile underlayment. Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10" x 3133/8" ASTM D 1970 glass- fiber /polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a tile roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self - adhering, glass - Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber /polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof file underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13116 Approval Date: 09/15/11 Page 2 of 8 PRODUCTS DESCRIPTION: NOA No.: 11- 0601.10 Expiration Date: 09/13/16 MIAMI•DWE COUNTY Approval Date: 09/15/11 11111111••••• �- Page 3 of 8 Test Product Product Dimensions Specification Description Polystick Dual Pro Roll: ASTM D 1970 A rubberized asphalt self - adhering, glass - Manufacturing Location 61' x 3'3218" fiber /polyester reinforced waterproofing #2 60 mils thick membrane, specific for use as a high temperature underlayment. Designed as a metal roofing. MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Azency Test Identifier Test Name/Report Date Exterior Research & Design, LLC 11756.04.01 -1 TAS 103 04/27/01 11756.08.01 -1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08 -R1 TAS 103 12/04/08 P10870.04.09 TAS 103 /ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P36900.09.11 TAS 103 /ASTM D4798 & G155 09/01/11 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA - 005 -02 -01 ASTM D 4977 01/31/02 PUSA- 018 -02 -01 ASTM D 2523 07/14/03 PUSA- 035 -02 -01 TAS 103 09/29/06 PUSA- 033 -02 -01 ASTM D 1970 01/12/06 PUSA- 055 -02 -02 TAS 103 12/10/07 PUSA -083 -02 -01 TAS 103 06/30/08 PUSA- 089 -02 -01 TAS 103 /ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103 /ASTM D4798 & G155 04/01/08 RX14E8A TAS 103 /ASTM D4798 & G155 11/09/09 DX23D8B TAS 103 /ASTM D4798 & G155 02/18/10 DX23D8A TAS 103 /ASTM D4798 & G155 02/18/10 NOA No.: 11- 0601.10 Expiration Date: 09/13/16 MIAMI•DWE COUNTY Approval Date: 09/15/11 11111111••••• �- Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3 -' /Z" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Expos re Limitations (days) Tile Profile MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 5 of 8 Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 5 of 8 •• w r ~Y GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 11. Rooting Tiles (6 Max Per Stack) LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. Mu►Mx counlrr • Y BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 WRAMIDADE Approval Date: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 "metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"712" or greater. It is suggested that on pitch/slopes in excess of 6'/4 "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 401bs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 0601.10 MIAMbdAOe COUNTY Expiration Date: 09/13/16 ... ® Approval Date: 09/15/11 Page 7 of 8 V .� 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofmg Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 8 of 8