RF-13-2149Inspection Worksheet
Miami Shores Village
0
. 10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 199695 Permit Number: RF -9 -13 -2149
Scheduled Inspection Date: November 07, 2013
Inspector: Rodriguez, Jorge
Owner: RICHARDS, RANDALL
Job Address: 10666 NE 11 Avenue
Miami Shores, FL
Project: <NONE>
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number (305)335 -4848
Parcel Number 1122320280690
Contractor: A STAR CONTRACTORS INC Phone: 954- 922 -5990
Building Department Comments
NEW CONSTRUCTION TILE ROOF
INSPECTOR COMMENTS False
November 06, 2013 For Inspections please call: (305)762 -4949 Page 15 of 40
Inspector Comments
Passed
b
Failed
Correction
Needed ❑
Re- Inspection ❑
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
November 06, 2013 For Inspections please call: (305)762 -4949 Page 15 of 40
Lab Report No. 121919
F
Providing Solutions to the Roofing Industry C.A. #: 26095
Lab Certificate: 09- 0715.02
4
` CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE
TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106
PROPERTYADDRESS: 10666 NE 11`' Ave., Miami Shores PERMITNo:
OWNER ROOFING SQUARES• 2
CONTRACTOR: A Star Contractors ROOF PffcH.• 3:12
TTLE TYPE.- Flat .INSPECTOR INITIALS: JM
ATTACHMENT:- Polyfoam TEST DATE: 10/22113
Toe #inn lZm6nmanf• ninifal r hnfillnn f1FIC 9f n Tac4Tnhidufinn
Rani airad Tasfinn Fn
No.
RESULT
No.
RESULT
No.
RESULT
No.
RESULT
No.
RESULT
1 -3
Passed
THIS ROOF HAS: PASSED
N I FAILED I I THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI -DADE COUNTY
TAS 106.
R wed by:
e, i3
Alberto Cardona, P.E. -Lic #17138
10735 SW 216'h St. Tel: (305) 256 -4550
Unit 416 Miami, FL 33170 www.floridatec.net Fax (305) 256 -6833
Lab Report No. 121919
FLORIDA 76, C
Providing Solutions to the Roofing Industry C.A. #: 26095
x
Lab Certificate: 09- 0715.02
CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE
TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106
PROPERTYADDRESS: 10666 NE 11th Ave., Miami Shores PERMIT No.
OWNER
CONTRACTOR A Star Contractors
TILETYPE.• Flat
ATTACHMENT.- Polyfoam
Jim Fmjinmanf- ninifal rhnfillnn i1FIR qnn Tpc/Tah►datinn
ROOFING SQUARES:- 2
ROOF PffcH. 3:12
INSPECTOR INITIALS: 3M
TEST DATE. 10%22113
Ranuirad Tasfinn Fnrr
No.
RESULT
No.
RESULT
No.
RESULT
No.
RESULT
No.
RESULT
1 -3
Passed
THIS ROOF HAS: PASSED
IXI FAILEDI I THE STATIC TIPT,TFT IN ACCORDANCE WITH MIAMI -DADF, COT JNTY
TAS 106.
V1 ed by:
Alberto Cardona, P.E. -Lic #17138
10735 SW 216'` St. Tel: (305) 256 -4550
Unit 416 Miami, FL 33170 www.floridatec.net Fax (305) 256 -6833
I !I
11 �' 195 S. Andrews Ave., I Zrn. A -100, Ft. Lauderdale, FL 33301 -1895 — 954 - 831 -4000 - --
�jl I :, VALID OCtOBER 1, 2013 THROUGH SEPTEMBER 30, 2014
' I ,
r
DBA: A� STAR CON'T CTORS XXC RECBipfi #:ROOFIM814tET METAL
BU mess Name: Business Type: ( R00k ZNG CONTRACTOR)
Owner Name: m&Ri< eamp-RoN Business Opened: o3 /19/1999
'Business Location., 7314 HAYES :IT State /County /Cert/Reg :CCC057736
HOLLYWOOD Exemption Code:
Business Phone, 9 54 - 92 2 - 5 9 0*(
I • ;,; I' Rooms Seat �. 'Empfoys®s .. Machines Prof�essiott8�a
For Vorrtling aulsHess Ony
Number of MaChina s_
..,�:• -
•� 11A
Tax
Amount
Transfer Fuse
N
F Fee
Penalty
Prior Years
0011eatlon Cost
Total Paid
``.0:'0,`0.
'
t'!;.:. :0:•i3d
b.00
27.00
. .I
i
j THIS RECEIPT MUST BE I IOSTED CONSPICUOUSLY I'N YOUR PLACE OF. BUSINESS
THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is
non - regulatory in nature. You must meet all County and/or Municipality planning
WHEN VALIDATED and zoning requirements, This Business Tax Receipt must be transferred when
the business is sold, business name has changed or you have moved the
business location, This receipt does not indicate that the business is legal or that
I'; •; it is In compliance with State 'or local Iaws and regulations.
Address:
CAMERON
FAXES STREET
WOOD, FL 33020
2013 .2014
i r
f
e,
6
Receipt: #01A -12- 00010932
Paid 08/01/203.3 27.00
l
k
Miami Shores Village �
. g SEP 23 2013
p
P
Building Department Bx:
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: 305 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
FBC 20
BUILDING Permit No. _ r. _
PERMIT APPLICATION Master Permit No._ J 3 ��-
Permit Type: BUILDING ROOFING
JOB ADDRESS: V (9 IV
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel #:
Is the Building Historically Designated: Yes NO Flood Zone:
3 „
OWNER: Name (Fee Simple Titleholder): P-qz"— ° f C'l� phone#: k' _ `H,',
Address: ��� ' L
City: lv ` `1 State• Zip:
�- 1
Tenantl lessee Name: Phone #:
Email: �j , YV\-V'-, '
CONTRACTOR: Company Name: Phone #:
Address- 4 S 5
City : State: Zip:
fier Name: f3 Phone #:
tell, to Certification or Registration #: U Certificate of Competency #:
ntact Phone #: Email Address:
IGNER: Architect/Engineer: Phone#:
�U`
ue of Work for this Permit: $ Square/Linear Footage of Work:
of Work: ddition OAlteration ONew ORepair/Replace ODemolition
criptign of Work: — ��� qQ
�O.atC.iOliae`\
Color thru.file: Wp
Submittal Fee $ Permit Fee $
Scanning Fee $ Radon Fee $
Notary $ Training/Education Fee $
Double Fee $ Structural Review $
L CCF $ CO /CC $
_ DBPR $ Bond $
® Technology Fee $
TOTAL FEE NOW DUE $ 4u 1 143
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
1 4
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDMONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in go faith that a copy of the notice of commencement and construction lien law br re will be delivered to the person
whose pr erty i subject to attachment. Also, a certified copy of the recorded notice of comet ment must be posted at the job site
for the rst ins ction which occurs seven (7) days after the building permit is issue . In absence of such posted notice, the
inspec on will n t be approve d and LJ ' a inspection fee will c rged
Signature
\4 Signature
wner or Agent Contractor
The fo a' gin tru t was ac owledged b fore e s The foregoing instrument was acknowledged before me this
day of by day of , 20 3, by mod,
h_o i pe sonally known to me "wwh has produced is personally known to or who has produced
` /G111C� As identification and who did take as identification and who did take an oaj�
PUBLIC: --
SignA IIVUUUV
Print:
My Commission Expires:
APPROVED BY
C�8 \� �QS ida
k �10 \P� State of E10 Zz1 5)
9,10 c (es Sep 6810
E,9 12
e, Shcoo®
Plans Examiner
Structural Review
(Revised 3 /12/2012)(Revised 07 110 /07)(Revised 06 /10/2009)(Revised 3/15/09)
NOTARY PUBLIC:
Sign: K.t -'^
Print: 1 61 R
My Commission Expires
/l
Zoning
Clerk
EN
i;`
i�:
[ •.
CERTIFICATE OF LIABILITY INSURANCE
DATE (MM/OD/YYYY)
03/27/2013 01:34 PM
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE
OR PRODUCER AND THE CERTIFICATE HOLDEN.
IMPORTANT: if the cerficate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,
subject to the terms and conditions of the policy, certain policies may require an endorsement.' a statement on this certificate does
not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER
Hi
55
Da
hpgnt Risk Services LLC
1 LBJ Freeway, Suite 1200
las, X•75240
CONTACT NAME:
PRONE t� No � (800) 728 -0523 VAX (AA Nor. (972) 404 -0380
EaoDREas,
INSURED AFFORDING COVERAGE
NAIC S
INSURER A: Companion Property and Casualty insurance company
12157
INSURED:
A-
231:4
HO
Ph
Aspen Staff Leasing, Inc. 1 /c /f:
TAR CONTRACTORS, INC.
HAYESjT
LYWOOD, FL 33020
ne: (954) 922 -5990 Fax: (954) 922 -5486
I
INSURER B:
INSURER C:
EACH OCCURRENCE
INSURER D:
INSURER E: ?
INSURER F.
COVERAGES CERTIFICATE NUMBER! AC13- 62400007- 1179291 REVISION NUMBER:
I 11-Y
NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY
PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN
MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
LTR
TYPE OF INSURANCE
ADDL
INSR
SUSR
WVD
POLICY NUMBER
POLICY EFF
DATE M/DD
pp EXP
DATE D
LIMITS
AUTHR
OED REPRESENTATIVE
GENERAL LIABILITY
EACH OCCURRENCE
$
COMMERCIAL GENERAL LIABILITY
DAMAGE To RENTED
$
CLAIMS MADE ❑ OCCUR
❑
❑
MED EXP (Any one person)
$
PERSONAL & ADV INJURY
$
GENERAL AGGREGATE
$
EN'L AGGREGATE LIMIT APPLIES PER:
PRODUCTS - COMP /gP AGG
POLICY M Pp&- LOC
AUTOMOBILE LIABILITY
COMBINED SINGLE LIMIT
ANY AYT0
(Ea accident)
$
ALL OWNED AUTOS
k3QUILY INJURY (Per person
BODILY INURY (Per accident)
$
SCHE ULED AUTOS
❑
❑
PROPERTY DAMAGE
(Per accident)
$,
HIRED�4UTOS
NON-OWNED AUTOS
UMBRELLA UAB
CWMS MADE
EACH OCCURRENCE
$
EXCESS LIAB
OCCUR
❑
El
AGGREGATE
$
DEDUCTIBLE
$
RETENTION $
$
A
EMPLOYERS' LIABILITY
ANY PROPERIETOMXECU11VE YIN
OFFICERAEMBER EXCLUDED? O
(Mandatory in NH)
N/A
❑
DPE26272740360
04/01/2013
04/01/2014
X I T
E.L EACH ACCIDENT
$. 1000000
E.L. DISEASE - EA EMPLOYEE
$ 1000000
If yes, describe under
SPECIAL PROVISION below
E.L. DISEASE - POLICY LIMIT
$ 1000000
0
T
I
I
I
DES
1.
Leasing,
$t
RIPTION OF OPERATIONS /LOCATIONS/VEHICLES(Attached ACORD101, Additional Remarks Schedule, H more space is r"Wred
This certificate remains in effect, provided the client's account is in good standing with Aspen Staff
Inc.. Coverage is not provided for any employee for which the client is not reporting wages to Aspen
ff Leasing, Inc.. Applies to 100% of the employees of Aspen Staff Leasing, Inc. leased to A -STAR
CO
TRACTORS, INC., effective 04/01/2013 2. Insured is afforded Workers Compensation & Employers liability
&s
a co- employer under the policy for employees leased from Aspen Staff Leasing, Inc..
CE TIFICA E HOLDER
's%1Llro3 =I Ijr! I 11IT41I1k I
At %inu LO (ZUI WUD)
W 19$3 -ZU1U AGURD GUHPUF7ATIUN. All ngnI reserves.
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE .
EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH
CITY OF MIAMI SHORES
BUILDING DEPARTMENT
THE POLICY PROVISIONS.
10050 NE 2ND AVE
MIAMI SHORES, FL 331382304
AUTHR
OED REPRESENTATIVE
At %inu LO (ZUI WUD)
W 19$3 -ZU1U AGURD GUHPUF7ATIUN. All ngnI reserves.
i
ASTAR -1 OP ID: EwN
CERTIFICATE OP LIABILITY INSURANCE DATE(MM /DD/YYYY)
08/30/2013
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS .
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to
the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement(s).
PRODUCER Phone: 813 -963 -1669 nciA°MACT MORROW INSURANCE GROUP
MORROW INSURANCE GROUP
L NO C. OLNEY/A196064 Fax: 813 - 961 -3743 AICONN Ext : 813- 963 -1669 A C No : 813- 961 -3743
T 936 N RTH LE MABRY HIGHWAY aooREsS: EILEEN MORROWINSURANCE.NET
�T' MPA, FL'.33
VID' ERNAN CZ INSURER(S) AFFORDING COVERAGE NAIC #
INSURER A: CANAL INDEMNITY COMPANY 27790
N URED A -STAR CONTRACTORS, INC. INSURER B: AMERICAN STATES INS CO 19704
23 4 HAYES ST
INSURER C: PRINCETON EXCESS & SURPLUS
HOLLYWOOD, FL 33020
INSURER D:
INSURER E:
INSURER F:
t+V YGrvw CJ UtK I It-IUA I E NUMBER: REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, '
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
ILTR
TYPE OF INSURANCE
L
UB
POLICY NUMBER
POLICY M/DD/YYYY
POLICY EXP
LIMITS
A
{!
GENERAL LIABILITY
X COMMERCIAL GENERAL LIABILITY
CLAIMS -MADE OCCUR
X CONTRACTUAL LIAB
GL106075
09105/2013
09/05/2014
EACH OCCURRENCE
$ 1,000,00
PREMISES Ea occurrence
$ 50,00
MED EXP (Any one person)
$ 5,00
PERSONAL & ADV INJURY
$ 1,000,00
GENERAL AGGREGATE
$ 2,000,00
GE
L AGGREGATE LIMIT APPLIES PER:
PRO -
POLICY e LOC
PRODUCTS - COMP /OP AGG
$ 2,000,00
$
Ilili
y;
I,
AUT
MOBILE IIABILITY
ANY AUTO
ALL OWNE D (—� SCHEDULED
AUTOS X ' AUTOS
NON -OWNED
HIREDAU OS XI AUTOS
PIP FL X STATUTORY
01 C138682640
07/10/2013
07/10/2014
COMBINED SINGLE LIMIT
Ea accident
1,000,000
$
BODILY INJURY (Per person)
$
BODILY INJURY (Per accident)
$
X
PROPERTY DAMAGE
Per accident
$
X
PIP -BASIC
$ 10,00
C
UMBRELLA LIAB
EXCESS LIAB
X
OCCUR
CLAIMS -MADE
RXSLAW000104-02
09 /05/2013
09/0512014
EACH OCCURRENCE
$ 2,000,00
X
AGGREGATE
$ 2,000,00
DED 1 X I RETENTION $ 0
$
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY Y / N
ANY PROPRIETOR/PARTNER/EXECUTIVE
OFFICER/MEMBER EXCLUDED?
(Mandatory in NH)
i If yes, describe under
' DESCRIPTION OF OPERATIONS below
NIA
WCSTATU- OTH-
I IT R
E.L. EACH ACCIDENT
$
E.L. DISEASE -EA EMPLOYEE
$
E.L. DISEASE - POLICY LIMIT
$
QE$GRIPTI
Iii �
Iljl
s
N OF OPERATIONS 1 LOCATIONS i VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If more space is required)
II
i '
CITYMIS
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
CITY OF MIAMI SHORES THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ACCORDANCE WITH THE POLICY PROVISIONS.
BUILDING & ZONING DEPT
FAX 305 - 756 -8972 AUTHORIZED REPRESENTATIVE
10050 NE 2ND AVENUE
MIAMI SHORES, FL 33138 a., /�'t' • .� •
©1988 -2010 ACORD CORPORATION. All rights reserved.
I
ACORD 25 (2010105) The ACORD name and logo are registered marks of ACORD
If
C #620353
DEP
6 T
STATE OF FLORIDA
The ROOFING CONTRACTOR
Named below IS CERTIFIED '+
Under the provis©ris of Chaptf, V'
Expiration date: AUG 31, 2014
�. t -
CAMERON . .
A= STAR CON�C.TOR$
3625 N COUNTRY CLUB -DR'
AVENTURA FL.33020
RICK SCOTT
GOVERNOR
DISPLAY AS REQUIRED BY LAW
g CITY OF HOLLYWOOD LOCAL BUSINESS TAX RECEIPT
KEN LAWSON
SECRETARY
I
I
PRINT DA
THIS IS YOUR LOCAL BUSINESS TAX RECEFT. PLEASE DETACH AND POST IN A CONSP
PLACE AT THE BUSINESS LOCATION. PLEASE DO NOT REMIT ANY PAYMENT. THIS IS N
Business Name:
Business Location:
Business Class:
Tax Basis:
Receipt Number:
Receipt Year:
Expiration Dater
A -STAR CONTRACTORS, INC.
2314 HAYES ST
CONTRACTOR /ROOFING
1 WORKER (OWNER)
13 00038863
10/01/12
09/30/13
NEW CHARGES: (itemized Below) 190.00 Comments:
Base Fee 190.00
Additional Charges:
9 2r /jld
MLL
,.
TOTAL NEW CHARGES- 190.00
Penalty Amount: .00
Previous Balance Due: .00
TOTAL AMOUNT PAID 190.00
PURSUANT TO STATE LAW, THE LOCAL BUSINESS TAX IS LEVIED ON THE PRIVI EC.
DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON - REGULATORY IN Al
ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD Q E,,
MEAN THAT THE CITY HAS DETERMINED THAT THE EXISTING OR PROPOSED SE',
LOCATION IS LAWFUL. ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT D ES'I
LEGALIZE OR CONDONE THE NATURE OF THE BUSINESS BEING CONDUCTE
CONTRARY TO ANY LOCAL, STATE OR FEDERAL LAWS OR REGULATIONS.
�N
I
it
117
0.7/13/2012 2012 .127001501 CC057?3 i ; m s�•x s... °P. ^::
'',
The ROOFING CONTRACTOR
Named below IS CERTIFIED '+
Under the provis©ris of Chaptf, V'
Expiration date: AUG 31, 2014
�. t -
CAMERON . .
A= STAR CON�C.TOR$
3625 N COUNTRY CLUB -DR'
AVENTURA FL.33020
RICK SCOTT
GOVERNOR
DISPLAY AS REQUIRED BY LAW
g CITY OF HOLLYWOOD LOCAL BUSINESS TAX RECEIPT
KEN LAWSON
SECRETARY
I
I
PRINT DA
THIS IS YOUR LOCAL BUSINESS TAX RECEFT. PLEASE DETACH AND POST IN A CONSP
PLACE AT THE BUSINESS LOCATION. PLEASE DO NOT REMIT ANY PAYMENT. THIS IS N
Business Name:
Business Location:
Business Class:
Tax Basis:
Receipt Number:
Receipt Year:
Expiration Dater
A -STAR CONTRACTORS, INC.
2314 HAYES ST
CONTRACTOR /ROOFING
1 WORKER (OWNER)
13 00038863
10/01/12
09/30/13
NEW CHARGES: (itemized Below) 190.00 Comments:
Base Fee 190.00
Additional Charges:
9 2r /jld
MLL
,.
TOTAL NEW CHARGES- 190.00
Penalty Amount: .00
Previous Balance Due: .00
TOTAL AMOUNT PAID 190.00
PURSUANT TO STATE LAW, THE LOCAL BUSINESS TAX IS LEVIED ON THE PRIVI EC.
DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON - REGULATORY IN Al
ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD Q E,,
MEAN THAT THE CITY HAS DETERMINED THAT THE EXISTING OR PROPOSED SE',
LOCATION IS LAWFUL. ISSUANCE OF A LOCAL BUSINESS TAX RECEIPT D ES'I
LEGALIZE OR CONDONE THE NATURE OF THE BUSINESS BEING CONDUCTE
CONTRARY TO ANY LOCAL, STATE OR FEDERAL LAWS OR REGULATIONS.
�N
I
it
117
c,vp 2 Z�1
Code Edition 2010
HIGH - VELOCITY HURRICANE ZONES
Section A/ (General Information) Lf tj
Master Permit No. �� '�`'I Process No.
Contractor's Name
Job Address b �� /eE 1 �l ya t16
P
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ,W100mortar /Adhesive Set Tile
❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes
Shingles
❑ Prescriptive BUR -RAS 150
ROOF TYPE
ew Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ Maintenance
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF)
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow
scuppers and overflow drains. include dimensions of sections and levels. clearly
urentny mmenslons of elevated pressure zones and location of parapets.
2010 FLORIDA BUILDING CODE — RESIDENTIAL
AA o+
;®
F
10
a a
o
u
e...�
�.
ro
CL
{
L)
L
rte'
•i..
�
u
D ®
O
O- 0
z
(ice
O
o
C'3
B
m
(D Cn
AA o+
t
Z
HIGH - VELOCITY HURRICANE ZONES
Florida Building Code Edition 2010
High Velocfty Hurricane Zone Uniform Pennit Applicadon Form.
Section D (Steel) Sloped Roof System)
Roof System Manufacturer: 4'w An
IllProduct Approval Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
P1 • P2• 123•
Maximum Design Pressure
Product Approval Specific System:
Method of tile attachment:
Roof Slope:
2—:12
Steep Sloped Roof System Description
Deck Type:
�ype Und6fayff
Insulation
Fire
Ridge Ventilation?
Mean Roof Height:
2010 FLORIDA BUILDING CODE —RESIDENTIAL
Ca
r/
Rip
Covering: %
40�
& Size Drip
�Type
ge. i "A
44.23
HIGH- VELOCITY HURRICANE ZONES
Piorida Building Code Edition 2010
High Veloft Hurricane Zone Uniform Permit Application Form.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compared the values
for Mrwith the values from Mf. If the Mr values are greater than or equal to the Mr
values, for each area of the roof, then the file attachment method is acceptable
Method I "Moment Based Tile Calcu ti s Per RAS 127"
34� _ -J- Md =m
rl Product Approval Mr 1/0d
.33� - - M; JE = Mt Product Approval M, V e
(P3 4, x X - o - MQ 'M roduct Approval M;
Method 2 "Simplified Tile Calculation Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval n
Mr Required Moment Resistance`
Mean Roof Height
Roof Slope
15
20'
26'
30'
40'
2:12
34.4
36.6
38.2
38.7
42.2
3:12
32.2
34A
36.0
37.4
39.8
4:12
30A
32.2
33.8
36.1
37.3
6:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29A
30.6
32.4
7:12
24.4
26.9
27.1
28.2
30.0
'Must be used in conjunction with a list of moment based the systems endorsed by the
Broward County Board of Rules and Appeals.
For Uplift based tile systems use method 3. Compared the values for F' with the
values for Fr. If the F' values are greater than or equal to the Fr values, for each
area of the roof, then the tile attachment method is acceptable.
Method 3 "TJplift Based Tile Calculations Per RAS 127"
w: = _) - W: _ x cos 8. = Fri: F
(P2: ,- x 1: _ - _ x W: _ ._) - W: _ x Cos & -_ = Fr2: F
(P3:_x1:_ =!x w: =` )- W :_xcos0.•_= Fri: F
Where to Obtain Information
Descriplion
Symbol
Where to find
Design Pressure
Pl or P2 or P3
RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE
7
Mean Roof Height
11
Job site
Roof Slope
B
Job Site
Aerodynamic Multi lier
A
Product A
Restoring Moment due to Gravity
M
Product Alpmal
AttacrimentResistence
Mt
Product Approval
Required Moment Resistance
M,
Calculated
Minimum Attachment Resistance
F
Product val
Required Uplift Resistance
F
Calculated
Average Tile Wei t.
W
Product Approval
Tile Dimensions
1= length
W. Width
I Product Approval
All calculations must be submitted to the Building Official at the time of permit application.
44.24 2010 FLORIDA BUILDING CODE -RESIDENTIAL
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1. _ Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the agreement between the owner and the contractor.
2. P.. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renail d in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removin the existing roof system).
3. Al Common roofs: Common roofs are those which have no visible delineation between neighboring
units .e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or
owner uld notify the occupants of adjacent units of roofing to be performed.
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
e viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appea
5. Ponding water: The current roof system and /or deck of the building may not drain well and may
cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. " Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
ove ded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
i e or of the structure assembly (the building itself). The existing amounpofptfic ventilation shall not be
red d. It may be beneficial to consider additional venting which r u in extending the service life of the
rr of
r,. 9
Owner /Agent's Signature Date Contract Sig to _ to
Revised on 7/9/2009 LD
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 10- 0706.08 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12- 1218.14
Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 1 of 9
M11AM
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
NOTICE OF ACCEPTANCE (NOA)
www.mianddade.aov /uera
Hanson Roof Tile
1340 SW 34 Ave
Deerfield Beach, FL. 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 10- 0706.08 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12- 1218.14
Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub - Category: Roofing Tiles
Material: Concrete
1. SCOPE
This is a new system using Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian
Slate, as manufactured by Hanson Roof Tile Inc. in Deerfield Beach, Florida and described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Hanson Flat Tile
1= 17.25"
TAS 112
Flat, interlocking, concrete tile equipped with two
w =13"
nail holes. For direct deck or battened nail -on,
mortar or adhesive set applications.
Hanson Slate
1= 17.25"
TAS 112
Flat, interlocking, concrete tile equipped with two
w= 13"
nail holes. For direct deck or battened nail -on,
mortar or adhesive set applications.
Hanson Chalet Shake
1= 17.25"
TAS 112
Flat, interlocking, concrete tile equipped with two
w =13"
nail holes. For direct deck or battened nail -on,
mortar or adhesive set applications.
Hanson Southern Shake
1= 17.25"
TAS 112
Flat, interlocking, concrete tile equipped with two
w = 13"
nail holes. For direct deck or battened nail -on,
mortar or adhesive set applications.
Hanson Victorian Slate
1= 17.25"
TAS 112
Flat, interlocking, concrete tile equipped with two
w =13"
nail holes. For direct deck or battened nail -on,
mortar or adhesive set applications.
Trim Pieces
1= varies
TAS 112
Accessory trim, concrete roof pieces for use at hips,
w = varies
rakes, ridges and valley terminations.
varying thickness
Manufactured for each tile profile.
2.1 PRODUCT DESCRIPTION
1. Deerfield Beach, FL.
NOA No.: 12- 1218.14
Mi p4pe cot Expiration Date: 04/10/18
Approval Date: 03121/13
Page 2 of 9
2.2 SUBMITTED EVIDENCE:
Test Men cy
Test Identifier
Test Name/Report
Date
IBA Consultants, Inc.
2381 -265
TAS 112
Feb. 2008
Redland Technologies
7161 -03
Static Uplift Testing
Dec. 1991
Appendix III
TAS 102 & TAS 102(A)
The Center for Applied
94 -084
Static Uplift Testing
May 1994
Engineering, Inc.
TAS 101 (Mortar Set)
The Center for Applied
94 -060A
Static Uplift Testing
March, 1994
Engineering, Inc.
TAS 101 (Adhesive Set)
The Center for Applied
25- 7094 -2
Static Uplift Testing TAS 102
Oct. 1994
Engineering, Inc.
(4" Headlap, Nails, Direct Deck,
New Construction)
The Center for Applied
25- 7094 -8
Static Uplift Testing TAS 102
Oct. 1994
Engineering, Inc.
(4" Headlap, Nails, Battens)
The Center for Applied
25- 7094 -5
Static Uplift Testing TAS 102
Oct. 1994
Engineering, Inc.
(4" Headlap, Nails, Direct Deck,
Recover/Reroof)
The Center for Applied
25- 7183 -6
Static Uplift Testing TAS 102
Feb. 1995
Engineering, Inc.
(2 Quik -Drive Screws, Direct Deck)
The Center for Applied
25- 7183 -5
Static Uplift Testing TAS 102
Feb. 1995
Engineering, Inc.
(2 Quik -Drive Screws, Battens)
The Center for Applied
25- 7214 -1
Static Uplift Testing TAS 102
March, 1995
Engineering, Inc.
(1 Quik -Drive Screw, Direct Deck)
The Center for Applied
25- 7214 -5
Static Uplift Testing TAS 102
March, 1995
Engineering, Inc.
(1 Quik -Drive Screw, Battens)
Redland Technologies
7161 -03
Wind Tunnel Testing
Dec. 1991
Appendix II
TAS 108 (Nail -On)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
TAS 108 (Nail -On)
Redland Technologies
P0631 -01
Wind Tunnel Testing
July 1994
TAS 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
The Center for Applied
Project No. 307025
Wind Driven Rain TAS 100
Oct. 1994
Engineering, Inc.
Test #MDC -77
Nutting Engineering
13343.1
Physical Properties TAS 112
Aug. 2006
Celotex Corporation Testing
520109 -1
Static Uplift Testing TAS 101
Dec. 1998
Service
520111 -4
Celotex Corporation Testing
520191 -1
Static Uplift Testing TAS 101
March 1999
Service
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
May 2006
Walker Engineering, Inc.
Calculations
Restoring Moments
May 2006
Walker Engineering, Inc.
Evaluation Calculations
25 -7094
February 1996
Walker Engineering, Inc.
Evaluation Calculations
25 -7496
April 1996
NOA No.: 12- 1218.14
Expiration Date: 04/10/18
Approval Date: 03/21113
Page 3 of 9
2.2 SUBMITTED EVIDENCE:
Test Aaencv
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
3. LIMITATIONS
Test Identifier
Evaluation Calculations
Evaluation Calculations
Calculations
Test Name/Report
25 -7584
25- 7804b -8
25- 78044 & 5
25- 7848 -6
25 -7183
Two Patty Adhesive Set System
Date
December 1996
March 1995
April 1999
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set rile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Hanson Flat Tile including Slate, Chalet Shake, Southern Shake, and Victorian Slate and its components
shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS
120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile
Weight -W (lbf)
Length -1 (ft)
Width -w (ft)
Hanson Flat Tile including Slate,
11.6
1.4375
1.08
Chalet Shake, Southern Shake,
Shake, Southern Shake, and Victorian Slate
and Victorian Slate
Table 2: Aerodynamic Multipliers - I (ft)
Tile
A. (ft)
1 (ft3)
Profile
Batten Application
�lrect Deck Applicatio
Hanson Flat Tile including Slate, Chalet
0.304
0.330
Shake, Southern Shake, and Victorian Slate
NOA No.: 12- 1218.14
MIAMMADECOUNTY Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 4 of 9
Table 3: Restoring Moments due to Gravity - M9 (ft -lbf)
Tile
2 ":12"
3 ":12"
4 ":12"
5 ":12"
6 ":12"
7 ":12" or
Profile
38.1
17.2
including Slate,
Chalet Shake,
1 -10d Smooth or Screw
Shank Nail
7.3
greater
Hanson
Battens
Direct
Battens
Pirect
attens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Flat Tile
51.7
Deck
Deck
24.3
Deck
24.2
Deck
1 -10d Smooth or Screw
Shank Nail Eave Clip)
Deck
19.0
Deck
including
7.53
8.25
7.46
.17
7.35
8.05
7.20
7.88
7.02
7.69
6.83
7.48
Slate,
Installation with a 4" tile headlap and fasteners are located a min. of 2Y2" from head of tile.
Chalet
Shake,
Southern
Shake,
and
Victorian
Slate
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -lbf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Hanson Flat Tile
2 -10d Ring Shank Nails
30.9
38.1
17.2
including Slate,
Chalet Shake,
1 -10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
Southern Shake,
and Victorian Slate
2 -10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1 -10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3
24.2
1 -10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2 -10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2 -10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2 -10d Ring Shank Nails 50.3 65.5 48.3
Installation with a 4" tile headlap and fasteners are located a min. of 2Y2" from head of tile.
NOA No.: 12- 1218.14
Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 5 of 9
Table 6: Attachment Resistance Expressed as a Moment Mf (ft -lbf)
for Two Patty Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Minimum Attachment
Resistance
Hanson Flat Tile including Slate,
Adhesive2
31.3
Chalet Shake, Southern Shake, and
3M 2- Component Foam Roof Tile Adhesive AH -160
Victorian Slate
Slate, Chalet Shake,
Southern Shake, and
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13.9 grams.
3MTm 2-Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams.
Table 7:
Attachment Resistance Expressed as a Moment - Mf (ft -lbf)
Tile
for Single Patty Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Hanson Flat Tile including Slate,
Resistance
Hanson Flat Tile including
3M 2- Component Foam Roof Tile Adhesive AH -160
3M 2- Component Foam Roof Tile Adhesive AH -160
40.4
Slate, Chalet Shake,
Southern Shake, and
6 Seespecific mortar manufacturers Notice of Acceptance
Victorian Slate
4 Large paddy placement of 45 rams of 3M 2-Component Foam Roof Tile Adhesive AH -160.
5 Medium paddy placement of 24 rams of 3M 2-Component Foam Roof Tile Adhesive AH -160.
Table 8: Attachment Resistance Expressed as a Moment - Mf(ft -lbf)
for Mortar Set Systems
Tile
Tile
Attachment
Profile
Application
Resistance
Hanson Flat Tile including Slate,
Mortar Set6
39.0
Chalet Shake, Southern Shake,
and Victorian Slate
6 Seespecific mortar manufacturers Notice of Acceptance
NOA No.: 12- 1218.14
Me Coin Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 6 of 9
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail
Below), or following statement: "Miami -Dade County Product Control Approved ".
HANSON FLAT TILE INCLUDING SLATE, CHALET SHAKE, SOUTHERN SHAKE, AND VICTORIAN SLATE
(LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQmEMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
NOA No.: 12- 1218.14
Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 7 of 9
• • ••• • • 0000 ••• • •
• • • • •• • • • • •• •
AND /OR 0000. 0000.0 0 • 000 • • • • 0
• • • • • •• 0 • 0 • 0•
• • • • 0 • 0000 000 • •
HANSON FLAT TILE INCLUDING SLATE, CHALET SHAKE, SOUTHERN SHAKE, AND VICTORIAN SLATE
(LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQmEMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
NOA No.: 12- 1218.14
Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 7 of 9
PROFILE DRAWINGS
NOA No.: 12- 1218.14
Expiration Date: 04/10118
Approval Date: 03/21/13
Page 8 of 9
SOUTHERN SHAKE
VICTORIAN SLATE
END OF THIS ACCEPTANCE
NOA No.: 12-1218.14
MIAMI DARE Expiration Date: 04/10/18
Approval Date: 03/21/13
Page 9 of 9
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3Mrm 2- Component Foam Roof Tile Adhesive AH -160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12- 0228.18
MIAtNi•DADECt7UNTY Expiration Date: 05/10/17
�® Approval Date: 05110/12
Page 1 of 7
N
MIAMI -DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov /pera
3M Company
3M Center Building 0220- 05 -E-06
St. Paul, MN. 55144 -1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3Mrm 2- Component Foam Roof Tile Adhesive AH -160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12- 0228.18
MIAtNi•DADECt7UNTY Expiration Date: 05/10/17
�® Approval Date: 05110/12
Page 1 of 7
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as
determined by applicable building code, does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles
system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a
moment based system for single patty placement, and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product
Dimensions
Test
Product Descriution
Moisture Vapor Transmission
ASTM E 96
Specifications
ASTM D 2126
3MTM 2- Component Foam
N/A
TAS 101
Two component polyurethane foam adhesive
Roof Tile Adhesive AH-
160
Foam Dispenser RTF1000
N/A
Dispensing Equipment
ProPack® 30 & 100
N/A
Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160
roof tile adhesive.
MANUFACTURING LOCATION:
1.. Tomball, TX.
PHYSICAL PROPERTIES:
Property Test
Density ASTM D 1622
Compressive Strength ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2127
Moisture Vapor Transmission
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content ASTM D 2856
APPROVED
Results
1.61bs. /ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Fe
3.1 Perm / Inch
+0.07% Volume Change @ -40'F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
86%
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 2 of 7
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Aeency
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
#94 -060
TAS 101
04/08/94
257818 -1PA
TAS 101
12/16/96
Trinity Engineering
25- 7438 -3
SSTD 11 -93
10/25/95
25- 7438 -4
25- 7438 -7
SSTD 11 -93
11/02/95
25 -7492
SSTD 11 -93
12/12/95
Miles Laboratories
NB -589 -631
ASTM D 1623
02/01/94
Polymers Division
Ramtech Laboratories, Inc.
9637 -92
ASTM E 108
04/30/93
Southwest Research histitute
01- 6743 -011
ASTM E 108
11/16/94
01- 6739- 062b[l]
ASTM E 84
01/16/95
Trinity Engineering
7050.02.96 -1
TAS 114
03/14/96
Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98
528454 -9 -1
528454 -10 -1
520109 -1 TAS 101 12/28/98
520109 -2
520109 -3
520109 -6
520109 -7
520191 -1 TAS 101 03/02/99
520109 -2 -1
LnuTATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2- Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F W
2
F'=
MS
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 3 of 7
INSTALLATION:
1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160.
2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient
attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in
compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof file assembly NOA.
3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0
(B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per file as determined at calibration. No
other settings shall be approved.
6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or
ProPack® 30 & 100 dispensing equipment only.
7. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH -160 has been dispensed.
9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in
accordance with the 'Placement Details' herein. Each generic rile profile requires the specific placement noted
herein.
Table 1: Adhesive Placement For Each Generic Tile Profle
Tile Profile
Placement Detail
Single Paddy Weight
Min. (grams)
Two Paddy Weight per
paddy Min. (grams)
Flat, Low, High Profiles
#1
35
N/A
High Profile (2 Piece Barrel)
#1
17 /side on cap and 34/ an
N/A
Flat, Low, High Profiles
#2
24
N/A
Flat, Low, High Profiles
1 #3
1
8
NOA No.: 12- 0228.18
M M� Expiration Date: 05/10/17
.. � i Approval Date: 05/10112
Page 4 of 7
LABELING:
All 3MTM 2- Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE .PATTY
NO through pWdc mart
Paddy MyNd Toe)
o
1
2)Turn olvmaupoftdwmP1 =adhm e112hr.
101n.
EeueCaurte e
UrtdedeYmazrt
Fa�a
EaweouraeMIT.
EMClaure
appnx
4 fame e
1)PhoxM"h who" to able" 17to 23 wW2A for
VOceq�
NOtamgh ieemnait
egtaoeWeIncorttactwfth the p nth
2)Turn olvmaupoftdwmP1 =adhm e112hr.
701 hG FMM WW05edge0 COW 011a
ThenhoA ftfla o
UrtdedeYmazrt
°
em
n9
i
m mowwtva
Alu w8 mulaftmof
DOW
pvtUmovanmm mime
PoiMupNm�
ihodteteaveline.
�geso��
Eana rJoare We60e Faeda
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 5 of 7
ADHESIVE PLACEMENT DETAIL 2
SINGLE PATTY
NO through plastic cement My @M* Tile) Nall through plastic cement
Underlepnot
Tr in.
EmCmm
a Fascia
Emcoum EMCIM11
Drip edge
Iwo,
NOA No.:* 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 6 of 7
Nall through plastic cement
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Faddy
(between file)
P8*
(underlie)
IN,;
0501, , Single paddyy
3 In und rtile
Tx3 in.
Single paddy on 2 In. 4 In.
under-
,"Me"t
Single paddy In. X 7 11L medium
on top of bile a ae paddy eon
Fascia cDurasonly
Nell through plastic cement
rOV-3 In. x 3 in 4
Single Paddy
an undarlament
Single paddy '7%
on top of the
EaW Course
Nall through plastic ce
Undwisyment
pn.x31n.
Sin /glet 41n. 2 In.
paddyy on
undue
layment
Single paddy
on top of lie
Em
Courie 00
Paddy
an tie
EM Closure
2 �,.. Xr.7,,. ,,d,,M
sh
F paddy am course only
ascia
END OF THIS ACCEPTANCE
Single paddy under tie
Single paddy between file
2 In. x 7 In. medium
sin paddy am
course only
< Fade
Weephall
Eave closure
, Drip edge
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 7 of 7
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA # 09- 0806.07 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
dADo �a11 Approval Date: 09/15/11
Page 1 of 8
f
ROOFING COMPONENT APPROVAL
Cateeory Roofing
Sub - Category_ Underlayment
Material: SBS , APP Self- Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self - adhering, glass -
Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber /polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and roof
file underlayment.
NOA No.: 11- 0601.10
Expiration Date: 09/13116
Approval Date: 09/15/11
Page 2 of 8
Test Product
Product
Dimensions
Specification Description
Polystick MTS
Roll:
TAS 103 A homogeneous, rubberized asphalt
underlayment
65'8" x 3'33/8"
waterproofing membrane, glass fiber reinforced
Manufacturing Location
60 mils thick
with polyolefmic film on the upper surface for
#2
use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
Polystick IR -Xe
Roll:
TAS 103 and A fine granular /sand top surface self - adhering,
underlayment
65'x 3'33/8"
ASTM D 1970 APP polymer modified, fiberglass reinforced,
Manufacturing Location
Or 65' x 3'
bituminous sheet material for use as an
#1 & #2
80 mils thick
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
Polystick TU
Roll:
TAS 103 and A heavy granuled surface self adhering, APP
underlayment
32'10" x 3'3318"
ASTM D 1970 polymer modified, fiberglass or polyester
Manufacturing Location
100 mils thick
reinforced, bituminous sheet material for use as
#1 & #2
an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus
Roll:
TAS 103 and A non - wicking fabric surfaced, self - adhering,
underlayment
65' x 3'33/8"
ASTM D 1970 APP polymer modified, fiberglass reinforced
(Facer of Membrane
80 mils thick
with a high strength polyester fabric, bituminous
with surface printing)
sheet material for use an an underlayment in
Manufacturing Location
sloped roof assemblies. Designed as a metal
#1 & #2
roofing and roof tile underlayment.
Polystick TU P
Roll:
TAS 103 and A rubberized asphalt waterproofing membrane,
underlayment
32'10" x 3133/8"
ASTM D 1970 glass- fiber /polyester reinforced, with a granular
Manufacturing Location
130 mils thick
surface designed for use as a tile roof
#2
underlayment.
Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self - adhering, glass -
Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber /polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and roof
file underlayment.
NOA No.: 11- 0601.10
Expiration Date: 09/13116
Approval Date: 09/15/11
Page 2 of 8
PRODUCTS DESCRIPTION:
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
MIAMI•DWE COUNTY Approval Date: 09/15/11
11111111••••• �-
Page 3 of 8
Test
Product
Product Dimensions Specification Description
Polystick Dual Pro Roll:
ASTM D 1970 A rubberized asphalt self - adhering, glass -
Manufacturing Location 61' x 3'3218"
fiber /polyester reinforced waterproofing
#2 60 mils thick
membrane, specific for use as a high
temperature underlayment. Designed as a metal
roofing.
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test Azency
Test Identifier
Test Name/Report
Date
Exterior Research & Design, LLC
11756.04.01 -1
TAS 103
04/27/01
11756.08.01 -1
ASTM D 1970
08/14/01
02202.08.05
TAS 103
08/29/05
Trinity I ERD
P5110.08.07
TAS 103
08/29/07
P10870.09.08 -R1
TAS 103
12/04/08
P10870.04.09
TAS 103 /ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P36900.09.11
TAS 103 /ASTM D4798 & G155
09/01/11
PRI Asphalt Technologies
PRI01111
ASTM D 4977
04/08/02
PUSA - 005 -02 -01
ASTM D 4977
01/31/02
PUSA- 018 -02 -01
ASTM D 2523
07/14/03
PUSA- 035 -02 -01
TAS 103
09/29/06
PUSA- 033 -02 -01
ASTM D 1970
01/12/06
PUSA- 055 -02 -02
TAS 103
12/10/07
PUSA -083 -02 -01
TAS 103
06/30/08
PUSA- 089 -02 -01
TAS 103 /ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103 /ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103 /ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103 /ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103 /ASTM D4798 & G155
02/18/10
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
MIAMI•DWE COUNTY Approval Date: 09/15/11
11111111••••• �-
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non - insulated
Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self - adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3 -' /Z" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 4 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non-
structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used
in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous
assemblies listed except roof tile systems.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Expos re Limitations (days)
Tile Profile
MTS
IR -Xe
TU
TU Plus
TU P
Tile Pro
Dual Pro
Winter Haven, FL.
180
180
180
180
180
180
180
Hazelton PA.
N/A
30
30
180
N/A
N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9B -72 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and
mechanically fastened roof tile applications. Polystick IR -Xe, and Tile Pro are limited to mechanically
fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile
applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 5 of 8
Tile Profile
Polystick MTS
Polystick IR -Xe
Polystick TU, TU
Plus, TU P, Tile Pro
Flat Tile
Prohibited without battens
5:12
No limitation
Profiled Tile
Prohibited without battens
Prohibited
No limitation
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 5 of 8
•• w r ~Y
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
11.
Rooting Tiles
(6 Max Per Stack)
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
Mu►Mx counlrr
• Y
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
WRAMIDADE Approval Date: 09/15/11
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 "metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back - nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7"712" or greater. It is suggested that on pitch/slopes in excess of 6'/4 "/12 ", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric
Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of
repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over
the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The
repair should be installed in such a way so that water will run parallel to or over the top of all laps of the
patch.
10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 401bs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894 -4563.
NOA No.: 11- 0601.10
MIAMbdAOe COUNTY Expiration Date: 09/13/16
... ® Approval Date: 09/15/11
Page 7 of 8
V .�
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894 -4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofmg Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 11- 0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 8 of 8