Loading...
ELC-13-2137Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 199976 Permit Number: ELC -9 -13 -2137 Scheduled Inspection Date: September 30, 2013 Permit Type: Electrical - Commercial Inspector: Devaney, Michael Owner: INC, PUBLIX SUPERMARKETS, Job Address: 9050 BISCAYNE Boulevard Miami Shores, FL 33138- Project: <NONE> Contractor: TYCO INTEGRATED SECURITY comments FIRE ALARM Inspection Type. Final Work Classification: Addition /Alteration Phone Number (863)688 -747_ Parcel Number 1132060100010 INSPECTOR COMMENTS False Phone: (954)266 -5063 Inspector Comments Passed CREATED AS REINSPECTION FOR INSP- 199572. Need miami dade fire first. Failed Correction ❑ ��� �� Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. September 27, 2013 For Inspections please call: (305)762 -4949 Page 16 of 30 Ift g0q--69 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33 t38 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 F] BUILDING PERMIT APPLICATION Permit Type. Electrical 1 SEP 2 6 i 13C 20 (1) Permit No. e Lr, i e.J " R 15--+ Master Permit No. JOB ADDRESS: 7 VzJiJ /14 It Uf ('CJ Z If I. ° Wf, City: Miami Shores _ County: Miami Dade Zip: Folio/Parcel #: Is the Building Historically Designated: Yes NO OWNER: Name (Fee Simple Titleholder): Address: _._._yid !!B� X r— � City: . 'It" fL Tenant/Lessee Name: Email: Zone: 41, T State: % Zip:cG: CONTRACTOR: Company Name: TYCO INTEGRATED SECURITY Phone #: 954-266 -5063 Address: 10785 MARKS WAY City: MIRAMAR State: FL Zip: 33025 Qualilier Name: DAVID ZACHRY Phone #: 954 - 266 -5063 State Certification or Registration #: EF0000478 Certificate of Competency Contact Phone #: 954- 266 - 5$66 ",(OOL. Email Address: ,�A�'���! DESIGNER: Architect/Engineer: Value of Work for this Permit: $t Square/Linear Footage of Work: Type of Work: ©Address OAlteration Anew ❑Repair /Replace ❑Demolition Description of Work: etc, 0- 0-m'? � L:ry Xs� �:� ����: akfleeasY�sD ds�to$ tFwat:: �akg:+.,:s,: sYHa3s: ei� +Dk�:F���FOCS:s��teKo8:3� -k�a`� �E: ktak ':AZressA��� ?:�kekeks��o08ta� k��F�::+ta- ��kiu:l:%s �fis:2yc Submittal Fee $ �0 ® Permit Fee $ 14 099 CCF $ CO /CC $ Scanning Fee $ y Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Technology Fee $ TOTAL FEE NOW DUE $ ` c0i'Y') y Bonding Company's Name (if applicable) Bonding Company's Address city State Mortgage Lender's Name (if applicable) �Vd Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT," Notice to Applicant: As a condition to the issuance of a building pertnit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attaclunent. Also, a certified copy of the recorded notice of commencement rntrst be posted at the job site for the first inspection which occurs seven (7) days gf'ter the building permit is issued. In the absence of suc•IT posted notice. the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day of ,2 'by Rd)e^} •� 1Lc��tr 1ate`l , who ' ersonally kn wn to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Signature i Contractor The foregoing i [rument was ackno ledged b or met is-49! day of' a—' by W t 40� is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: SignC Print Print: My Commission Expires: �o +, .+�� MY COMMISSION # EE 056818 My C a-5 16 * * EXPIRES: February 5, 2015 - 11TFOF \o� Bonded Thru Budget Notary Services a, Y+ kkf• �4i�skdtolc ,b>b�RkRSAYg• =A@isi Hci: =�rYB '[84�ARt'�e�$�k�.�k�SBs��k�k�i A�%iSJakk�aki S,i Y,CA«f�"Rt:xoL oR�: Ynf,�hi ae:y >6at FSi A• air /3 APPROVED BY �� Plans Examiner Structural Review (Revised 311212012)(Revised 07t10107)(Revised 0611012009)(Revised 3/15104) METH OMIA BECK MY COMMISSION # EE 014432 EXPIRES: March 16, 2015 aded Ttau Noteni Pu1iUo UndavA Zoning Clerk i� J�� jqoq _0cj r ` d NOTE: ALL SHEETS MIDST BE REVIEWED MIAMI -DADE COUNTY BUILDING DEPARTMENT Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street (Coral Way), • Miami, Florida 3x175 -2474 - (786) 315 -2100 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI -DADE FIRE RESCUE AND /OR DEPARTMENT OF ENVIRONMENTAL RESOURCES MANAGEMENT (te - in - Ir_% 1cl�,As' PROVIDE MUNICIPAL PROCESS NUMBER HERE 45poso � � D. Contractor No. Job Address 7 Last four (4) digits of Qualifier No.�' LL F Z w Folio M Z I- o Contractor Name �GO ilU %�'+ AA-Z" StCOL% a o Lot Block Q � Qualifier Name z 0 IL Subdivision PBpg Z ° ° ? Address [ a� f�$ /lq.KS I�lli4 ~� y- Metes and bounds —' City t�'11�,f}� State f Zip 02� [ ] New Construction on [ ] Demolish [ ] Shell Only Current use of property ST�8 / fn U. z Vacant Land alteration Interior [ ] Addition Attached [] Addition Detached tion of Work Description P 0 r ?' elocution of Structure [� Foundation Only [ ] Enclosure Sq. Ft. Units Floors - [ ] Repair Value of Work [ ] Repair Due to Fire [ ] MBLD * [ ] Chg. Contractor Owner hc. Address ��S� o"°�. `3& Category � [ ] Re -Issue W City State Zip 4?_ ?4W F MELE < ] MLPG [ ] Re -stamp N x Phone w [ ] MMEC W > [ ] Revision W o Last four (4) digits of a [ ] FIRE [ ] Not Applicable for Owner's Social Security No. Fire Name Name Address Address 04 z J 0 w Fz City State Zip City State Zip 0 Y U -a Z a. U Phone �.�� ��� J ®� a W Phone 1 am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible at the rate of $190 for the first hour and J ? _ $65 per each addition hour in addition to the review fees. Minimum charge one -hour. a3: 1" Request: Date: vnww LU a w 2 "0 Request: Date: a I 3`d Request: Date: a I am requesting Optional Plan Review (OPR) to be scheduled as soon as possible at the rate of $75 for each discipline. Additional F review fees may apply. 0 0 1s` Request: Date: oo w 2 "d Request: Date: 3`d Request: Date: o Y: Fo v asoi n_-trluniciP1 Pc h Appli"111 Ala Radionics" Control Features • Eight programmable areas, each with perimeter /interior partitioning. Regular, master, associate, or shared option by area • Real time clock and test timer • Up to 1000 event log, including time, date and event with area, point and user number • Battery charging circuit, AC power and voltage supervision • Automatic reset circuit protectors • on -board CPU watchdog warning buzzer and diagnostic LEDs • Lightning and EMI protection • Power limited external circuits Communicator • Built -in digital communicator with phone line monitor (loop or ground start) Multiple telephone numbers, primary and duplicate paths with main and alternate destinations • All Reports within each 4 route groups are programmable • Optional dual phone line switcher monitors 2 phone lines • Automatic test and status reports • Time windows for arming and open/ close report suppression • Programmable answering machine work - around for remote program- ming on shared phone lines Programmable Outputs • 2 -amp alarm power @ 12 VDC • 1.4 -amp aux power @ 12 VDC • 4 alarm output patterns • Automatic bell test • Programmable bell shut -off timer • D7212ID7412: 67 programmable relay outputs. D9112/D9412: 131 programmable relay outputs L923 PIN 39173B (6198) 9000 Series Control /Communic-�f -�rr -,- Integrated Security Systems for Intrusion, Fire and Access Control (Models: D7212, D7412, D9112, and D9412) System Response • D7212ID7412: 75 points, 8 on- board, up to 67 off -board D9112JD9412: 246 points, 8 on- board, up to 238 off -board • 31 custom point indexes, including fire supervisory • Selectable point response time • Fire alarm verification • Fire inspector's local test • Watch mode • Scheduled events (Skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, control door access and more User Interface • Supervises up to 8 command centers (up to 32 non - supervised command centers can be used) • Custom command center text • D7212ID7412: 4 custom functions D9112ID9412: 16 custom functions • Full function command menu including custom functions • D7212/D7412: 99 Users D9112/D9412: 249 Users • Each user has authority by area and 16- character name • 14 custom authority levels control user's authority to change, add, delete passcodes or access control tokens /cards, disarm, bypass points, initiate system tests, and more • Adjustable brightness /loudness for command center display /sounder • D7212/D7412: 1 parallel printer D9112ID9412: 3 parallel printers Access Control (D7412/D9412) • D7412: 2 access control doors and 396 tokens /cards D9412: 8 access control doors and 996 tokens /cards • Custom door strike, point shunt and auto disarming response by area • Logging options for: Access Granted, No Entry, Request to L-<it and Request to Enter • 14 -panel wide access levels with both manual and scheduled control 9000 Series Specification Sheet © 1998 Radionics, Inc. 017 System Description 9000 Series Control /Communicators provide an integrated solution to Access Control, Security, and Fire Alarm System applications. Control / Communicators are capable of monitoring alarm points for intruder or fire alarms while operating user command centers, (access readers, door locks - D7412/ D9412), and other outputs. Includes a built -in digital communicator which reports events to selected destinations via 4 programmable route groups. Programming and accessory modules offer flexibility and beneficial features rarely found in other security control systems. Area Configurations 9000 Series' area programming offers you a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master /associate). User Interface 9000 Series command centers provide on- premises point and system status annunciation. A fully selectable user interface can customize command center displays and simplify operation by creating menu items and functions, appropriate only to that command center. Function Lists can help a user become familiar with the operation of the control panel. Custom functions allow users to perform complex functions with a few keystrokes. Each may be programmed and identified by 16 characters of custom text and contain up to 32 keystrokes. D1255 Command Center, D1256 Fire Alarm Command Center and D1257 Fire Alarm Annunciator use a 16- character English language display to show system status, area status (custom text), and point status (custom text). D720 8 -point LED area command center provides command functions and annunciation for up to 8 points in a single area. Any combination of these command centers may be used within the same area. Easy to remember commands like Command 1, Command 2, and Command 8 make an easy transition for seasoned Radionics users- User Passcodes 9000 Series can accommodate: D7212ID7412: 99 user passcodes D9112/D9412: 249 user passcodes. (Each passcode individually programs with 3 to 6 digits in length and no fixed digits). Each user is assigned one of 14 customized authority levels in each area. You may restrict passcodes to operate only during certain times. Each user may have a 16- character customized name that may be viewed, printed, reported to a central station in radionics' Modem 111a2w Communications format or retrieved with Remote Account Manager (RAM). L923 P/N 39173B (6/98) 2 Security and Fire Detection 9000 Series provide eight "on- board" detection points, up to 238 additional off -board points (depending on Model and expansion interfaces). Points may be individually programmed and used to monitor all types of burglar alarm, fire alarm, and supervision devices. Communications 9000 Series have four route groups, sorts reports by priority and are capable of transmitting reports to up to four locations_ Each group has a programmable primary and backup destination. Radionics' Modem llla2TTM Communications Format, available with Radionics' D6500 Receiver, adds these reporting capabilities. To name just a few: • Individual point numbers and text • Opening /Closing reports by area number • Remote programming attempts • Diagnostic reports • Access control events with user name Event Log Storage, Viewing and Printing 9000 Series' event log automatically stores up to 1000 events. All local and transmitted events are stored (some access events are selectable). Event log includes time, date and event, with area, point and user number. Users may view event log from Alpha Command Centers. Events may be retrieved remotely using RAM. Events print as they are stored in event log. D9131A Parallel Printer Interfaces can be installed to record events locally on one, two, or three printers (depending on model). Each can print opening and closing, access, alarm, Skeds, or any combination of events. Each can print information from any combination of areas. Each can supervise various printer status conditions. Event log and local printer are ideally suited for customers who like to have a record of openings and closings without having extra communications costs. Logger and Remote Account Manager, can suppress reports and then retrieve events periodically using one phone call, rather than receiving several calls each day. When the panel's event log reaches its programmed threshold of stored events, it can send a report to D6500 Receiver to remind central station to retrieve events from the panel's event log with Remote Account Manager. Scheduled Events (Skeds) 9000 Series' internal clock and calendar help the panel operate individually scheduled events (Skeds). Skeds performs a specific function (such as arm /disarm, relay control, point bypassing, etc.). Each Sked is programmed for a time - and - day -of -week schedule or a date -of -year schedule. Users may change Sked Time if programmed for local time editing. Holiday schedules can enable or disable individual Skeds during holiday periods. • 64 scheduled events with up to 26 different functions Day -of -week or date -of -year schedules Four holiday schedules of 366 days each (leap year) 9000 Series Specification Sheet ©1998 Radionics, Inc. Fire Test 9000 Series Fire Test Mode suppress reports to central station so you can test initiating and indicating devices without transmitting alarms. Initiating Fire Test Mode, sends "Fire Walk Start" to central station indicating start of test. Test events become "local only". Command center shows how many points are to be tested. Each time a device initiates an alarm, programmed point text displays at command center and fire bell rings for 2 seconds. Automatic sensor reset feature allows continued testing of devices without time consuming trips to manually reset sensors. At the end of test, command center displays number of untested points. You can also view point text for each untested point. Ending Fire Test Mode, sends "Fire Walk End" to central station indicating end of test. Combining Access Control with Security and Fire Detection (D7412/D9412) 9000 Series' combined systems can help prevent false alarms making it easy to use one system that controls access, security, and fire functions. Access control features of D7412/D9412 can deny access during armed periods, grant access onlyto certain authorized users depending whether an area is master armed, perimeter armed or disarmed. Alarm system can automatically disarm when designated authorized users are granted access. D7412: Two (2) access doors / 75 detection points D9412: Eight (8) access doors / 246 detection points D921 0B Access Control Interface Module Access is granted from Wiegand format readers or Request to Enter /Exit devices when connected to D921013. Also provided are connections for door point, strike, buzzer and enclosure tamper. (One D921 0B required per door). • Each access door can be configured independently • Door point controls access door and is part of alarm system (door does not need double contacts) Door contact can reset strike time when opened • Door contact can terminate entry buzzer (if used) Door contact is shunted when valid access is granted • Optional buzzer can trigger prior to end of door shunt period, warning user a "door left open" condition is about to occur. • Door point can be configured to generate alarm or trouble (or have no response) when door is left open beyond shunt period • In addition to granting access, cards control whether system will disarm along with granting access • Door strike can release automatically during disarmed periods, then automatically re -lock when area is armed • Door can generate an alarm, trouble, (or have no response) depending on area's armed condition when door is opened outside authorized access period • REQUEST TO ENTER and REQUEST TO EXIT can be programmed to shunt door without activating strike • An option determines whether access granted, no entry, request to enter, or request to exit messages are sent to event log © 1998 Radionics, Inc. Specifications General Contractor shall furnish and install, where indicated on plans, a Radionics 9000 Series Control /Communicator. Panel shall be listed by Underwriters Laboratories for NFPA 72 Applications. 9000 Series shall support initiating and indicating modules and Radionics Command Centers. Power supply shall provide 1.4 -amp @12 VDC for all processing functions and auxiliary requirements. Software 9000 Series' programming of all system functions shall be accomplished on site using Radionics D5200 Programmer or remotely using Remote Account Manager software package. A programmable system passcode shall be used to prevent unauthorized remote programming. Panel shall accommodate up to four separate telephone numbers for primary, alternate and backup receivers, automatic test reports, selective relay activation, and custom text on associated command centers and annunciators. When resetting alarms, arming or disarming a combination fire /burglary and /or access control system, user shall be identified by name and number. D7212/D7412: Up to 99 users D9112/D9412: Up to 249 users Panel's internal clock shall support Skeds (scheduled events) feature. User shall have option to alter Sked activation times using a programmable passcode. Up to 64 programmable scheduled event functions shall be available for controlling relays, enabling passcodes, windows, and supporting service alert feature. Other programmable functions shall include fire alarm reset commands, and day /date /time adjustments. Event Logger /Clock 9000 Series' event log shall store up to 1000 events. All system events shall include time, date and event with area, point and user number. Access events (optional) stored shall include: Access granted, no entry, Request To Enter, and Request To Exit. Logger records certain functions entered at command centers. Stored events in Logger shall be retrievable with a Remote Account Manager software package. Remote Diagnostics and Controls 9000 Series shall be able to be remote controlled through use of Remote Account Manager software. Features shall include: reset of audible signals, activation /deactivation of D8129 relays, interrogation of battery, point and armed status, enabling or disabling reporting functions, and shunting of reporting points during servicing. Command Centers 9000 Series command centers shall be Radionics Command Center, D1256 Fire Alarm Command Center and D1257 Fire Alarm Annunciator. Each shall be equipped +:v €tit a 16- characteralphanumericdisplay, distinct fire and burglary tones, and backlighted multi -key touchpad. 9000 Series Specification Sheet L923 39;;"-,-, , 3 I Specifications (cont'd) Command Centers (Cont'd) D1255, D1256, and D1257 shall have the ability to display for each detection point: alarm, trouble, supervisory, or faulted, and custom text. In addition, expanded, addressable point displays shall include missing and extra point information. System -wide displays shall include: local system test, sensor reset, fire test mode, and user programming prompts. Fire Test 9000 Series' Fire Test Mode shall support single - person operation. All reports to central station shall be suppressed while fire test is being conducted. Fire Test Mode shall be activated by entering a user passcode at command center. All testing data shall be visible on command center and annunciator displays during testing. Hardware 9000 Series shall provide up to 246 individually identified addresses, (75 with D7212/D7412). Each shall accommodate normally open and /or normally closed devices with end -of- line resistor supervision. Each point shall be programmable for fire, fire supervisory or burglary applications. Point output shall be silent or audible. Audible output shall be steady, pulsed, CA standard, or temporal code 3. External Hardware 9000 Series shall allow use of up to three on -site parallel printers (one with D7212/D7412), using Radionics D9131A Printer Interface Modules. Events shall print time, date, and event description with area, account, point, and user number, including text for points and users. Installation, Warranty, and Training 9000 Series System Installation, wiring of initiating devices and signaling circuits, shall be the responsibility of installing company. Warranty on all components shall be one year, subject to manufacturer's limitations. Training on complete system operation shall be furnished by installing company upon completion of installation. Listings and Approvals Fire UL: Central Station, Local, Auxiliary, Remote Station, and Household Fire Warning. CFSM, FM and NYC -MEA approved. Burglary UL: Central Station, Local, Police Connect, Bank Safe and Vault, Mercantile Safe and Vault, and Grade A Household DOD: Approved for installations in Sensitive Compartmented Information Facilities (SCIF). Access UL: Access Control Systems- e 1998 Radonics, Inc., Salinas, CA, USA A9 rights reserved Salinas, CA- L923 - The Radlonics logo is a registered trademark of Radionics. Inc.. 4 Accessories Command Centers, Keypads and Accessories: D1255 Command Center D1256 Fire Alarm Command Center D1257 Fire Alarm Annunciator D720 8 Point LED Area Command Center D268 Independent Point Control Module Keypad D269 D279 Independent Point Control Independent Point Control D54B Command Center Flush Mount Kit, Brass D54C Command Center Flush Mount Kit, Stainless D55 Command Center Desk Stand D56 Command Center Surface Mnt. Conduit Box Zone Expansion and Interface Modules: D8125MUX Multiplex Interface Module D8125 D9127U/T POPEX Module POPIT Module, U =No Tamper / T= Tamper D8128C OctoPOPIT Module D940 Super Loop Module D8129 OctoRelay Module D127 Reversing Relay D136 D8121A Plug -in Relay Derived Channel S.T.U. Non UL D8122 Derived Channel S.T.U. UL Listed D9131A Parallel Printer Interface Module D921 0B Access Control Interface Module Detection Devices with Built -in POPIT: ZX835 PIR/Microwave Detector, 35 ft. x 35 ft. 7x970 PIRIMicrowave Detector, 60 ft. x 60 ft. ZX935Z PIR Detector, 35 ft. x 35 ft. ZX776Z PIR Detector, 50 ft. x 50 ft. ZX794 PIR Detector, 90 ft. x 90 ft. ZX938Z PIR Detector, Ceiling Mount, 360° x 60 ft. D278S Smoke Detector Base 12 VDC D298M Smoke Detector Base, Master, 24 VDC D298S Smoke Detector Base, 24 VDC Fire Alarm Modules and Accessories: D125B Dual Class B Powered Loop Interface Module D129 Dual Class A Initiation Circuit Module D130 Auxiliary Relay Module, 12/24 VDC D184 Auxiliary Local Energy Interface Kit D185 Reverse Polarity Interface Module D192C N.A.C. Module, Class B, 12/24 VDC, 1.8 amp D192D N.A.C. Module, Class A/B, 12/24 VDC; 3 -amp D928 Dual Phone Line Switcher D8130 Release Module Power Supplies,Transformers, Batteries Sr Accessories: D9142F Auxiliary Power Supply, 24 VDC, 4 -amp D8132 Battery Charger Module, 12 VDC D1640 16.5 VAC 40 VA Transformer D113 Battery Lead Supervision Module D1221L Dual Battery Harness /Long Leads D126 Battery, 12 V, 7 Ah D1218 Battery, 12 V, 17.2 Ah Enclosures, Brackets, and Phone Cords: D8103 Universal Enclosure D8109 Fire Enclosure D8108A Attack Resistant Enclosure D8004 Transformer Enclosure D137 Module Mounting Bracket D101 Lock and Key for D8103 D1611162 Dual Mod. Telephone Phone Cord, 7 ft. /2 ft. Programming Products: D5200 Programmer D5400 Remote Account Manager, RAM P/N 39173B (6198) RQdIOnICS ^ Radionics, Inc., 1800 Abbott Street Salinas, CA, 93901, USA ISO 900-. , CERTIFICATE NO. A3946 COOPER Notification ' F.MrED . R­ Finally, Design and Safety Meet... Description: The Wheelock" Exceder'" Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance . low current draw, no tools needed for setting changes.. voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction_ The Wheelock" Excederr'' Series incorporates high reliability and high eff iciency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit All strobe models feature an industry first of 8 candela settings on a single appliance Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock& ExcederTI Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation" Sleek Modern Aesthetics vw Finger Slide Switches = Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB 8 Candela Settings Wall - 15/1575/30/75/95 /110/135/185 ° Ceiling - 15/30/60/75/95/115 /150/177 Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types It Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelocko Sync Modules or panels with built -in Wheelock° Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage' range Compared to competitive models "' Patented Compared to previous models .._........ s IL Ceiling all Description: The Wheelock" Exceder'" Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance . low current draw, no tools needed for setting changes.. voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction_ The Wheelock" Excederr'' Series incorporates high reliability and high eff iciency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit All strobe models feature an industry first of 8 candela settings on a single appliance Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock& ExcederTI Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation" Sleek Modern Aesthetics vw Finger Slide Switches = Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB 8 Candela Settings Wall - 15/1575/30/75/95 /110/135/185 ° Ceiling - 15/30/60/75/95/115 /150/177 Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types It Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelocko Sync Modules or panels with built -in Wheelock° Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage' range Compared to competitive models "' Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A, All warnings are printed in bold capital letters. Il WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USIN, OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE To INSTALLATION AND /OR OPERATION OF TI N CAUTIONS WARNINGS HESE RODUCTS IN AN EM RGGENCY SITUATION, WHICH COULD RESSULT IN PRO ERTY DAMAGE, AND APPLICATION, SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: General Notes- • Strobes are designed to flash at 1 flash per second minimum over their - Regulated Voltage Range'. Alf candela ratings represent minimum effective strobe intensity based on UL Standard 1971 • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32'F to 120'F (0`C to 49'C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). • Seres Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Hnrn �trnhe Ratinas Der UL 1971 & UL 464 at 24 VDC UL Max Current* - 24 VDC / 24 FWR 12 VDC Regulated Voltage Range VDC Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Model Range VDC 60 75 24 VDC 95 110 115 135 150 177 185 12 VDC 15 15/75 Regulated Voltage Model Range VDC - 0.135 0.163 0-182 0.205 0.253 0.110 0 140 HS 8.0 -33.0 0.082 ST 8.0 -33.0 0.057 0 070 0 085 0 191 0.242 STC 0-33 .0 0.061 :7 0.085 0103 0.135 0.163 0.102 0 -182 0.148 0.205 0.253 0 197 0.110 ' Hnrn �trnhe Ratinas Der UL 1971 & UL 464 at 24 VDC Horn Ratings per UL 464 Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN UL Max Current* at 99 dBA HNC 16 -33.0 0.084 0.044 0.022 HN 5 15/75 30 60 75 24 VDC 95 110 115 135 150 177 185 12 VDC 15 15/75 Regulated Voltage Model Range VDC HS 8.0 -33.0 0.082 0.176 0 191 0.242 0 282 0.125 0 159 HSC 8.0-330 0.082 0.102 0 1 11 0.148 0.1 i Specification & Ordering Information _ – Sync wl SM, Mounting Strobe DSM or 12124 VDC' options Model Candela PS -6 & PS -8 r . X UMB" HSR 15/1575/30/751951110/1351185 X UMB" 1511575/30/7 519 5/1101135/18 5 X X — • HSW _— X UMB' HSRC 15130160/75195/115 /150/177 X — —__ -- UMB" HSWC 15/30/6 0/7 519 5111 5 /1 5 0/17 7 X X X UMB" 1 5/1 5 7 5/3017 5/9 5/110/135/18 5 X STR X UMB" 1 511 57 5/3 0/7 5/9 5/110/ 1 3 5 /18 5 X " STW — X UMB STRC 15/30/6 017 5/9 5111 5 /1 50 /17 7 X UMB" STWC 15/30/60/75/95/115 /150/177 X X x Tex X X UMB" HNR ? a X UMB" HN4N� zs a X UMB" V HNRC s — UMB" X X HNWC,� _ a — "UMe = Universal Mounting Base 11 R 15/75 settings NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accotuall- with Cooper Wheelock Inc_ dba Cooper Notification standard terms and conditions_ Architects and Engineers Specifications The notification appliances shall be Wheelock"" ExcederT"' Series HS Audible Strobe appliances Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired) for Indoor Fire Protection Service, The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with I standard reverse polarity supervision of circuitwiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series ITS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan© lens. The Series shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30 75 95 110 135, 185 candela for wall mount and 15, 30 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs - orporate a patented Universal Mounting Base that shall allow The Series HS Audible Strobe, ST Strobe and Series HN Audible shall inc mounting to a single -gang, double - gang 4 -inch square, 3.5 -inch octal, 4 -inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed Product shall come with Contact Cover to protect contact springs. Removal an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D Series HN wall shall measure 5 24' H x 4.58' W x 1.6° D The Series HSC and STC shall been round and have a low profile with a diameter of 6 68° x 2 63' D Serves HNC ceiling shall have a diameter of 6 68° x 1.50' D When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Portier Supplies or other manufacturer's panels with built -in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation_ If the sync protocol fails to operate, the strobe shall revert to a non - synchronized flash -rate and still maintain ( 1 ) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances — UL Standard 1971 UL Standard 464, California State Fire Marshal (CSFM)_ ULC Ceiling Appliances — UL Standard 1971 UL Standard 464, California State Fire Marshal (CSFM)_ULC - FMMARA WANM Via' WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY r_.__.a.._ c--- Czh__f 111f1Q WAVES .., a VVVrC §t li N1 U Ll l l U a L1 Cooper Notiticafion is Wheelock' ML EDV SAPEPATH s �J -_ i If Radionics'" Control Features - Eight programmable areas, each with perimeter /interior partitioning. Regular, master, associate, or shared option by area - Real time clock and test timer f • Up to 1000 event log, including time, date and event with area, point and user number • Battery charging circuit, AC power and voltage supervision • Automatic reset circuit protectors • On -board CPU watchdog warning buzzer and diagnostic LEDs • Lightning and EMI protection Power limited external circuits Communicator Built -in digital communicator with phone line monitor (loop or ground start) Multiple telephone numbers, primary and duplicate paths with main and alternate destinations All Reports within each 4 route groups are programmable Optional dual phone line switcher monitors 2 phone lines Automatic test and status reports • Time windows for arming and open/ close report suppression • Programmable answering machine work - around for remote program- ming on shared phone lines Programmable Outputs • 2 -amp alarm power @ 12 VDC • 1.4 -amp aux power @ 12 VDC • 4 alarm output patterns • Automatic bell test • Programmable bell shut -off timer • D7212ID7412: 67 programmable relay outputs D9112/D9412: 131 programmable relay outputs L923 PIN 391738 (6198) 9000 Series Control /Communic�f rc Integrated Security Systems for Intrusion, Fire and Access Control (Models: D7212, D7412, D9112, and D9412) System Response • D7212ID7412: 75 points, 8 on- board, up to 67 off -board D9112ID9412: 246 points, 8 on- board, up to 238 off -board 31 custom point indexes, including fire supervisory • Selectable point response time • Fire alarm verification • Fire inspector's local test • Watch mode • Scheduled events (Skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, control door access and more User Interface • Supervises up to 8 command centers (up to 32 non - supervised command centers can be used) • Custom command center text • D7212ID7412: 4 custom functions D91121D9412: 16 custom functions • Full function command menu including custom functions D7212/D7412: 99 Users D9112/D9412: 249 Users Each user has authority by area and 16- character name 14 custom authority levels control user's authority to change, add, delete passcodes or access control tokens /cards, disarm, bypass points, initiate system tests, and more Adjustable brightness /ioudness for command center display /sounder • D7212ID7412: 1 parallel printer D9112ID9412: 3 parallel printers Access Control (D7412/D9412) • D7412: 2 access control doors and 396 tokens /cards D9412: 8 access control doors and 996t6kens /cards • Custom door strike, point shunt and auto disarming response by area • Logging options for. Access Granted, No Entry, Request to `Ai and Request to Enter • 14 -panel wide access levels with both manual and scheduled control 9000 Series Specification Sheet © 1998 RadiOniCS, Inc. System Description 9000 Series Control /Communicators provide an integrated solution to Access Control, Security, and Fire Alarm System applications. Control / Communicators are capable of monitoring alarm points for intruder or fire alarms while operating user command centers, (access readers, door locks - D74121 D9412), and other outputs. Includes a built -in digital communicator which reports events to selected destinations via 4 programmable route groups. Programming and accessory modules offer flexibility and beneficial features rarely found in other security control systems. Area Configurations 9000 Series' area programming offers you a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master /associate). User Interface 9000 Series command centers provide on- premises point and system status annunciation. A fully selectable user interface can customize command center displays and simplify operation by creating menu items and functions, appropriate only to that command center. Function Lists can help a user become familiar with the operation of the control panel. Custom functions allow users to perform complex functions with a few keystrokes. Each may be programmed and identified by 16 characters of custom text and contain up to 32 keystrokes. D1255 Command Center, D1256 Fire Alarm Command Center and D1257 Fire Alarm Annunciator use a 16- character English language display to show system status, area status (custom text), and point status (custom text). D720 8 -point LED area command center provides command functions and annunciation for up to 8 points in a single area. Any combination of these command centers may be used within the same area. Easy to remember commands like Command 1, Command 2, and Command 8 make an easy transition for seasoned Radionics users. User Passcodes 9000 Series can accommodate: • D72121D7412: 99 user passcodes D9112ID9412: 249 user passcodes. (Each passcode individually programs with 3 to 6 digits in length and no fixed digits). Each user is assigned one of 14 customized authority levels in each area. You may restrict passcodes to operate only during certain times. Each user may have a 16- character customized name that may be viewed, printed, reported to a central station in radionics' Modem 111a2, Communications format or retrieved with Remote Account Manager (RAM). L923 P/N 39173B (6198) 2 Security and Fire Detection 9000 Series provide eight "on- board" detection points, and up to 238 additional off -board points (depending on Model and expansion interfaces). Points may be individually programmed and used to monitor all types of burglar alarm; fire alarm, and supervision devices. Communications 9000 Series have four route groups, sorts reports by priority and are capable of transmitting reports to up to four locations. Each group has a programmable primary and backup destination. Radionics' Modem Ilia I Communications Format, available with Radionics' D6500 Receiver, adds these reporting capabilities. To name just a few: • Individual point numbers and text • Opening /Closing reports by area number • Remote programming attempts • Diagnostic reports • Access control events with user name Event Log Storage, Viewing and Printing 9000 Series' event log automatically stores up to 1000 events. All local and transmitted events are stored (some access events are selectable). Event log includes time, date and event, with area, point and user number. Users may view event log from Alpha Command Centers. Events may be retrieved remotely using RAM. Events print as they are stored in event log. D9131A Parallel Printer Interfaces can be installed to record events locally on one, two, or three printers (depending on model). Each can print opening and closing, access, alarm, Skeds, or any combination of events. Each can print information from any combination of areas. Each can supervise various printer status conditions. Event log and local printer are ideally suited for customers who like to have a record of openings and closings without having extra communications costs. Logger and Remote Account Manager, can suppress reports and then retrieve events periodically using one phone call, rather than receiving several calls each day. When the panel's event log reaches its programmed threshold of stored events, it can send a report to D6500 Receiver to remind central station to retrieve events from the panel's event log with Remote Account Manager. Scheduled Events (Skeds) 9000 Series' internal clock and calendar help the panel operate individually scheduled events (Skeds). Skeds performs a specific function (such as arm /disarm, relay control, point bypassing, etc_). Each Sked is programmed for a time -and- day -of -week schedule or a date -of -year schedule. Users may change Sked Time if programmed for local time editing. Holiday schedules can enable or disable individual Skeds during holiday periods. 64 scheduled events with up to 26 different functions Day -of -week or date -of -year schedules • Four holiday schedules of 366 days each (leap year) 9000 Series Specification Sheet © 1998 Radionics, Inc. Fire Test 9000 Series Fire Test Mode suppress reports to central station so you can test initiating and indicating devices without transmitting alarms. Initiating Fire Test Mode, sends "Fire Walk Start" to central station indicating start of test_ Test events become "local only". Command center shows how many points are to be tested. Each time a device initiates an alarm, programmed point text displays at command center and fire bell rings for 2 seconds. Automatic sensor reset feature allows continued testing of devices without time consuming trips to manually reset sensors. At the end of test, command center displays number ' of untested points. You can also view point text for each untested point. Ending Fire Test Mode, sends "Fire Walk End" to central station indicating end of test. Combining Access Control with Security and Fire Detection (D74121D9412) 9000 Series' combined systems can help prevent false alarms making it easy to use one system that controls access, security, and fire functions. Access control features of D7412/D9412 can deny access during armed periods, grant access onlyto certain authorized users depending whether an area is master armed, perimeter armed or disarmed. Alarm system can automatically disarm when designated authorized users are granted access. • D7412: Two (2) access doors / 75 detection points D9412: Eight (8) access doors 1246 detection points D921 0B Access Control Interface Module Access is granted from Wiegand format readers or Request to Enter /Exit devices when connected to D9210B. Also provided are connections for door point, strike, buzzer and enclosure tamper. (One D921 0B required per door). • Each access door can be configured independently • Door point controls access door and is part of alarm system (door does not need double contacts) • Door contact can reset strike time when opened • Door contact can terminate entry buzzer (if used) • Door contact is shunted when valid access is granted • Optional buzzer can trigger prior to end of door shunt period, warning user a "door left open" condition is about to occur. • Door point can be configured to generate alarm or trouble (or have no response) when door is left open beyond shunt period • In addition to granting access, cards control whether system will disarm along with granting access • Door strike can release automatically during disarmed periods, then automatically re -lock when area is armed • Door can generate an alarm, trouble, (or have no response) depending on area's armed condition when door is opened outside authorized access period REQUEST TO ENTER and REQUEST TO EXIT can be programmed to shunt door without activating strike • An option determines whether access granted, no entry, request to enter, or request to exit messages are sent to event log © 1998 Radionics, Inc. Specifications General Contractor shall furnish and install, where indicated on plans, a Radionics 9000 Series Control /Communicator. Panel shall be listed by Underwriters Laboratories for NFPA 72 Applications. 9000 Series shall support initiating and indicating modules and Radionics Command Centers. Power supply shall provide 1.4 -amp @12 VDC for all processing functions and auxiliary requirements. Software 9000 Series' programming of all system functions shall be accomplished on site using Radionics D5200 Programmer or remotely using Remote Account Manager software package. A programmable system passcode shall be used to prevent unauthorized remote programming. Panel shall accommodate up to four separate telephone numbers for primary, alternate and backup receivers, automatic test reports, selective relay activation, and custom text on associated command centers and annunciators. When resetting alarms, arming or disarming a combination fire /burglary and /or access control system, user shall be identified by name and number. D7212ID7412: Up to 99 users D9112/D9412: Up to 249 users Panel's internal clock shall support Skeds (scheduled events) feature. User shall have option to alter Sked activation times. using a programmable passcode. Up to 64 programmable scheduled event functions shall be available for controlling relays, enabling passcodes, windows, and supporting service alert feature. Other programmable functions shall include fire alarm reset commands, and day /date /time adjustments. Event Logger /Clock 9000 Series' event log shall store up to 1000 events. All system events shall include time, date and event with area, point and user number. Access events (optional) stored shall include: Access granted, no entry, Request To Enter, and Request To Exit. Logger records certain functions entered at command centers. Stored events in Logger shall be retrievable with a Remote Account Manager software package. Remote Diagnostics and Controls 9000 Series shall be able to be remote controlled through use of Remote Account Manager software. Features shall include: reset of audible signals, activation /deactivation of D8129 relays, interrogation of battery, point and armed status, enabling or disabling reporting functions, and shunting of reporting points during servicing. Command Centers 9000 Series command centers shall be Radionic Command Center, D1256 Fire Alarm Command Center ,n l D1257 Fire Alarm Annunciator. Each shall be equipped \Mli a 16- character alphanumeric display, distinct fire and burglary tones, and backlighted multi -key touchpad. 9000 Series Specification Sheet 7923 391 .,. 3 Specifications (cont'd) Command Centers (Cont'd) D1255, D1256, and D1257 shall have the ability to display for each detection point: alarm, trouble, supervisory, or faulted, and custom text. In addition, expanded, addressable point displays shall include missing and extra point information. System -wide displays shall include: local system test, sensor reset, fire test mode, and user programming prompts. Fire Test 9000 Series' Fire Test Mode shall support single - person operation. All reports to central station shall be suppressed while fire test is being conducted. Fire Test Mode shall be activated by entering a user passcode at command center. All testing data shall be visible on command center and annunciator displays during testing. Hardware 9000 Series shall provide up to 246 individually identified addresses, (75 with D7212/D7412). Each shall accommodate normally open and /or normally closed devices with end -of- line resistor supervision. Each point shall be programmable for fire, fire supervisory or burglary applications. Point output shall be silent or audible. Audible output shall be steady, pulsed, CA standard, or temporal code 3. External Hardware 9000 Series shall allow use of up to three on -site parallel printers (one with D7212/D7412), using Radionics D9131A Printer Interface Modules. Events shall print time, date, and event description with area, account, point, and user number, including text for points and users. Installation, Warranty, and Training 9000 Series System Installation, wiring of initiating devices and signaling circuits, shall be the responsibility of installing company_ Warranty on all components shall be one year, subject to manufacturer's limitations. Training on complete system operation shall be furnished by installing company upon completion of installation. Listings and Approvals Fire UL: Central Station, Local, Auxiliary, Remote Station, and Household Fire Warning. CFSM, FM and NYC -MEA approved. Burglary UL: Central Station, Local, Police Connect, Bank Safe and Vault, Mercantile Safe and Vault, and Grade A Household DOD: Approved for installations in Sensitive Compartmented Information Facilities (SCIF). Access UL: Access Control Systems. ®1998 Radionics, Inc., Salinas, CA, USA AD rights reserved. - The Radionics logo is a registered trademark of Radionics, Inc., Salinas, CA- L923 P/N 391736 (6198) 4 Accessories Command Centers, Keypads and Accessories: D1255 Command Center D1256 Fire Alarm Command Center D1257 Fire Alarm Annunciator D720 8 Point LED Area Command Center D268 Independent Point Control Module D269 Independent Point Control Keypad D279 Independent Point Control D54B Command Center Flush Mount Kit, Brass D54C Command Center Flush Mount Kit, Stainless D55 Command Center Desk Stand D56 Command Center Surface Mnt. Conduit Box Zone Expansion and Interface Modules: D8125MUX Multiplex Interface Module D8125 POPEX Module D9127U/T POPIT Module, U =No Tamper IT= Tamper D8128C OctoPOPIT Module D940 Super Loop Module DB129 OctoRelay Module D127 Reversing Relay D136 Plug -in Relay D8121A Derived Channel S.T.U. Non UL D8122 Derived Channel S.T.U. UL Listed D9131A Parallel Printer Interface Module D921 0B Access Control Interface Module Detection Devices with Built -in POPIT: ZX835 PIR/Microwave Detector, 35 ft. x 35 ft. ZX970 PIRIMicrowave Detector, 60 ft. x 60 ft. ZX935Z FIR Detector, 35 ft. x 35 ft. ZX776Z FIR Detector, 50 ft. x 50 ft. ZX794 FIR Detector, 90 ft. x 90 ft. ZX938Z FIR Detector, Ceiling Mount, 360° x 60 ft. D278S Smoke Detector Base 12 VDC D298M Smoke Detector Base, Master, 24 VDC D298S Smoke Detector Base, 24 VDC Fire Alarm Modules and Accessories: D125B Dual Class B Powered Loop Interface Module D129 Dual Class A Initiation Circuit Module D130 Auxiliary Relay Module, 12124 VDC D184 Auxiliary Local Energy Interface Kit D185 Reverse Polarity Interface Module D192C N.A.C. Module, Class B, 12124 VDC, 1.8 -amp D192D N.A.C. Module, Class A/B, 12124 V,:,,r. ;-amp D928 Dual Phone Line Switcher D8130 Release Module Power Supplies, Transformers, Batteries 8r Accessories: D9142F Auxiliary Power Supply, 24 VDC, 4 -amp - D8132 Battery Charger Module, 12 VDC D1640 16.5 VAC 40 VA Transformer D113 Battery Lead Supervision Module D1221L Dual Battery Harness /Long Leads D126 Battery, 12 V, 7 Ah D1218 Battery, 12 V, 17.2 Ah Enclosures, Brackets, and Phone Cords: D8103 Universal Enclosure D8109 Fire Enclosure D8108A Attack Resistant Enclosure D8004 Transformer Enclosure D137 Module Mounting Bracket D101 Lock and Key for D8103 D1611162 Dual Mod. Telephone Phone Cord, 7 fL /2 ft. Programming Products: D5200 Programmer D5400 Remote Account Manager, RAM Radionics, Inc., 1800 Abbott Street Radionics_ Salinas, CA, 93901, USA ISO 900" CERTIFICATE NO. A3946 POWERPATHTm NAC POWER SUPPLIES PS -6 Description The Wheelock Series PS -6 and PS -8 are 24VDC, filtered and regulated, supervised remote power supply /battery chargers are used for supervision and expanded power driving capability of Fire Alarm Notification Appliance Circuits. The PS -6 provides 6 amps of power distributed across 4 outputs, while the PS -8 provides 8 Amps across 4 output. In addition the PS -8 provides additional room in the chassis for accessories like an Addressable Control Module, with mounting studs. The Power Supplies may be connected to any 12V or 24V (FWR or DC) Fire Alarm Control Panel (FACP) by using a Notification Appliance Circuit (NAC) or a "Dry Contact ". Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories. This unit provides filtered and regulated 24VDC, up to four (4) Class "B ", two (2) Class "A ", or two (2) Class "B" and one (1) Class "A" Notification Appliance Circuits. With the optional plug -in PS -EXP module the unit supports (8) Class "B" or (4) Class "A" Notification Appliance Circuits. Additionally, an auxiliary power output of 2.5 Amps (disconnected upon AC power loss or an alarm condition) or up to 0.240 A of constant power on the PS -8 and 0.075 A of constant power on the PS -6. The Wheelock Power Supplies can accommodate 7 or 12 AH batteries inside its lockable chassis. Using an external battery cabinet it can charge up to 33 AH batteries (pending UL testing). Two FACP NAC circuits or two "Dry" contact initiating circuits can be connected to the inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 3.0 Amps (Class "B ") or (Class "A ") and can be programmed to generate a steady or Code 3 Temporal Horn sound and a strobe output under alarm condition. Total load for the PS -6 and PS -8 NAC circuits must not exceed the power supplies rated output. The Power Suppliesunder non -alarm condition provides independent supervision for Class "A" and Class "B" FACP NAC circuits. In the event of circuit trouble, the FACP will be notified via the POWERPATH steered input (IN1 or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles. The AC power loss reporting, on the common trouble terminals and on IN1 or IN2, can be delayed for either 30 seconds or 170 minutes. The AC power loss terminals will always report the trouble within 1 second after loss of AC power. M EA $ APPROVED 151.92 -E PS -8 PS -EXP The PS -6 and PS -8 Power Supplies are UL Listed under UL Standard 864, 9th Edition to be used with any 24 volt Listed Regulated notification appliances. They include the capability to synchronize Wheelock strobes and horns and to silence the horn signal when horn /strobes are operating on two wires. Approvals • Approvals Include: UL Standard 864, 1481, California State Fire Marshal (CSFM), Factory Mutual (FM) • Pending: New York City (MEA), Chicago (BFP) See Approvals by model in Specification and Ordering Information • Compliant with NFPA 72 Inputs • 120VAC. 50 /60Hz. 4.25 Amps (PS -6/8) and 5.32 Amps (PS -8) Operating Power in Alarm • 240VAC. 60Hz, 2.42 Amps (PS -6E and 3.22 Amps (PS -8E) ' Operating Power in Alarm • 24VDC Battery Backup Connection • Two (2), 12V or 24V NAG Initiating Circuits (8 -33V at 5mA) FWR or DC • Two (2) "Dry" Contact initiating Circuits • Accepts two (2) Class "A" or two (2) Class "B" circuit inputs • Built in battery charger for sealed lead acid or gel type batteries ...Features continued on next page Outputs • NAC outputs are 24VDC, 3.0 Amps each, power limited • 8 Amps on PS -8 and 6 Amps on the PS -6 total alarm current • Capable of four (4), Class "B" circuits • Capable of two (2) Class "A" ci; cuits • Capable of one (1) Class "A" circuit and two (2) Class "B" circuits • Capable of (8) Class "B" or four (4) Class "A" circuits with optional PS -EXP module • Temporal (Code 3), constant voltage output, Wheelock Sync output or True input to output follower mode • Built -in Wheelock synchronization mode that can be fed to any or all of the output circuits • Input and output can be synchronized with "IN >OUT SYNC" mode (SM, DSM, 2nd POWERPATHT'^ or FRCP with synchronization protocol is required) • Audible silence capability • Filtered and electronically regulated output • 2.5 Amp auxiliary power limited output with reset capability. (Removed upon AC loss or alarm. Automatic reset 30 seconds after AC power returns or the alarm condition is over) or 0.075 Amps (PS -6) or 0240 Amps (PS -8) of auxiliary power limited output which remains on during AC loss or an alarm condition when configured for 24 hour battery backup Supervision • Compatible with 12V or 24V (FWR or DC) FACP • Signaling appliance circuits are supervised and steered to either IN1 or IN2 • 10K Ohm, 1 Watt (Wheelock Model #MPEOL) End of Line Resistor (EOLR) for supervision of all outputs • 37 distinguishable trouble diagnostics • AC loss trouble reported over a separate set of contacts (delay of 1 second) • All troubles are reported over the common trouble contacts (AC loss can have a delay of 30 seconds or 170 minutes) • Automatic switchover to standby battery when AC fails • Thermal and short circuit protection with auto reset • Input and output status LED indicators • AC fail supervision • Battery presence and low battery supervision • Ground Fault Detection, with diagnostics to indicate which circuit fault is on • Latching LED's for NAC trouble annunciation and Diagnostic trouble LED's (latching can be disabled) Power • Not Battery Dependent • Automatic switch over to standby batteries when AC fails • Supports sealed lead acid or gel type batteries • Fused battery protection • Thermal and short circuit protection with auto reset • Supports both 7AH or 12AH batteries in the same cabinet POWERPATH TM Operating Modes (refer to Installation Manua ): Normal Mode: Provides constant 24 VDC output upon initiation by a voltage to input IN1 or IN2 or by a contact opening on DRY1 or DRY2. The unit returns to standby mode when the input is deactivated. Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock audible and strobe notification appliances. Audibles can also be silenced in this mode while the strobes continue to flash. In >Out Sync Mode: Accepts a synchronization signal on the input to provide a coded output or synchronized output. This signal may come from a FACP, another POWERPATH or a Wheelock SM or DSM synchronization module. Caution: Do not use strobes on coded output circuits. True Input Follower Mode: Accepts a coded signal on the input to provide a coded output with the same timing as the input. The signal may come from a FACP, another POWERPATH or other coded source. Caution: Do not use strobes on coded output circuits. Temporal Mode: Codes the output voltage in a code -3 temporal pattern to drive audible appliances such as horns, bells or chimes. Caution: Do not use strobes on coded output circuits. Snecificatinns anrd Orderina Information Model Number Order Code Input Voltage /Current Approvals UL CSFM FM PS -6 105530 6 amp, red enclosure X X X PS -613 100257 6 amp, black enclosure X X X PS -8 105531 8 amp, red enclosure X X X PS -88 105830 8 amp, black enclosure X X X PS -6EXP 105083 6 amp power supply with preinstalled expansion module X X X PS -8EXP 105084 8 amp power supply with preinstalled expansion module X X X PS -EXP 105534 4 class B or 2 class A expansion module X X X PS- EXP -RETRO 105527 Field upgrade kit for models prior to January 2010 X X X Input Circuit Input Voltage and Current = Approved Input voltage Range 8 to 33 VDC = Pending Input Current @ 12 VDC 0.005 amps = Contact Technica for Input Current @24 VDC 0.005 amps upport addition nforamation on upc Output Circuit Output Voltage and Current ptions Four (4) Class B or 24 VDC @ up to 3 amps per curcuit Two (2) Class A or One (1) Class A and Two (2) Class °B" or 8 Class B or 4 Class A (optional PS -EXP module necessary) Continuous duty up to 3 Amps per circuit, up to 4 Amps maximum per panel Standby Current 0.129 Amps Alarm Current 0.129 Amps Primary PS -6 (120 VAC models) 105 to 130 VAC, 50/60 Hz @ 4.25 Amps Primary PS -8 (120VAC models) 105 to 130 VAC 50/60 Hz @ 5,32 Amps Primary PS -6E (240 VAC models) 210 to 260 VAC, 50/60 Hz @ 2.42 Amps Primary PS -8E (240 VAC models) 210 to 260 VAC 50/60 Hz @ 3.22 Amps Secondary Power Charging Capacity 32 Amp hours @ 0.750 Amps per hour Enclosure can house up to two 12 AH batteries Aux Output CP Mode PS -6 up to 75 mA PS -8 up to 250 mA MP Mode 2.5A during non alarm Model Dimensions Weight Comments PS- 6 /PS -613 17 "H x 13 "W x 3.5 "D 11.5lbs. (Ship) 9.4lbs (Unit) Small profile PS- 8 /PS -8B 17 "H x 15 "W x 5.5 "D 17.7lbs (Ship) 15.6ibs (Unit) Additional room for modules PS -EXP 4.3 "H x 3.7 "W x 1 "D 1 lb. (Ship & Unit) Plugs into main pcb on all models al rade Architects and Engineers Specifications The power supply shall be Wheelock POWERPATHT"' Series PS -8, or equivalent. The unit shall be stand alone power supply intended ,for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power Iimitnd operation of outputs and comply with NFPA 70 (NEC), article 760. The power supply shall support a full 8A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" opening. The units shall be 8 ampere, 24 VDC, regulated and filtered, supervised remote power supply /charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class "B ", two Class "A ", or two Class "B" and one Class "A" NAC circuit(s). Eight Class "B" or Four Class "A" circuits shall be available with an optional PS -EXP module. The PS -8 unit shall supply up to 240 mA of auxiliary power that is available during both non -alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non - alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be at 3 amperes for Class "B" applications or 3 amperes each for Class "A ". The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class "A" or Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and /or no battery condition(s). Standby current for battery back up shall be 0.129 Amps max. The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified. The cabinet dimensions shall be 17" H x 15" W x 5.5" D. The power supply shall be Wheelock POWERPATHTM Series PS -6, or equivalent. The unit shall be stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 Listed for power limited operation of outputs and comply with NFPA 70 (NEC), article 760. The power Supply shall support a full 6A of notification power even if the battery is in a degraded mode and only AC power is connected. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a "Dry contact" opening. The units shall be 6 ampere, 24 VDC, regulated and filtered, supervised remote power supply /charger. It shall operate over the voltage range of 8 to 33 VDC or FWR. The primary application of the unit shall be able to expand fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories or functions. The power supply shall provide four Class "B ", two Class "A ", or two Class "B" and one Class "A" NAC circuit(s). Eight Class "B" or Four Class "A" circuits shall be available with an optional PS -EXP module. The PS -6 unit shall supply up to 200 mA of auxiliary power that is available during both non -alarm and alarm or auxiliary power of not less than 2.5A at 24 VDC during non - alarm. The power supply shall be capable of charging batteries of up to 33 ampere hours per NFPA 72 at a maximum rate of 0.750 Amps per hour. Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A ". The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supply shall provide independent loop supervision for either Class "A" or Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAC circuit. The units shall have common trouble terminals. The power supply shall be powered from a 120 VAC source with a current consumption of xx amperes max. The unit shall incorporate short circuit protection with auto reset. The power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to report low battery and /or no battery condition(s). Standby current for battery back up shall be 0.130 Amps max. The power supply shall have the ability to latch trouble LED's so the circuit in trouble can be identified. The cabinet dimensions shall be 17" H x 13" W x 3.5" D. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLA- TION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE. AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accor- dance with Wheelock Inc. standard terms and conditions. A KAM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 1 YEAR WARRANTY Made in USA 59100 PS -6 & A I2 /09 Cooper Notification is Wheelock" (M__E_DC_J SAFEPATH, wave COOPER Notification Mc- F -10D . • AD`i` -DG-10 Series Manual Fire Alarm Pull Station Section: Conventional Initialing Devices GENERAL The ADT -BG -10 Series Manual Fire Alarm Stations provide dual- acUoh, normally -open contact alarm initiating points for use with UL fisted fire alarm control panels. The ADT -BG -10 Series features non - coded, dual- action operation. FEATURES • Within ADA 5 lb. pull force when used without break -tube (models manufactured after 10 -1 -96, identified by an under station spring). • impact - resistant, durable L-EXANe)(orpoiycarbonateequiva- lent) housing. • Backplate made of 16 gauge steel. • Highly visible. • Easily operated. • Attractive shape-with textured finish. • Semi -flush or surface mounting. • Operates with or without a break tube. • Handle latches in down position to clearly indicate that the stailon has been operated. • Optional lock with standard Fre•Lite[ADT key, • Optional N.O. contact for auxiliary functions. • .Optional pre - signal circuit. - Spanish (FUEGO) version avaitabte. APPLICATIONS The ADT -BG -10 Series manual fire alarm stations are in- tended for use as fire alarm initiating devices, with any fire alarm Initiating circuit to be operated by a contact closure. The stations are for indoor or outdoor (BG -10WP) use and should be installed in compliance with appftcable NFPA stan- dards, local building codes, and plans and specifications. INSTALLATION The ADT -BG -10 Series manual fire alarm stations mount to standard single -gang electrical boxes. A terminal block with screws allows for fast and easy wiring. _. OPERATION Pulling the haniile down causes the ADT -SG-10 to latch in the down position and to close the normally -open switch. The handle is restored manually by unscrewing the alien -head Ocrew so the top of the case can pivot forward, allowing the `spring - loaded handle to return to its normal position. The case can then be pivoted back to its normal position and secured with the alien -head screw. The ADT- 13G -101- utilizes a mechanical key instead of the alien -head screw. October 24, 2000 I California �D� u State e F FV ire ® Marshal 7150- 0085 :176 S285 {ADT- 8G -10, ADT -8 (3 -10L) (ADT -sG• ro, Aar -sG -rot} The 8G -10P/T has a normally -open auxiliary switch which is closed by rotating a key.lockwise. (The key is non - removable in this position.) SPECIFICATIONS Physical (rnm) ADT -BG -10 SS -10 WA -10 Height: 5.500" (139.700} 5.500" (139.700) 8.00' (152.400) Width_ 4 -125" (104.775) 4.125" (104.775) 4.69' (119.126) Depth: 1375' (34.925) 1.375" (34,325) 2.00' (50.800) EI ectdcal: Current Capacity: 3 Amps @ 30 VwAs_ LEXANG is a registered trademark of GE Plastics, a subsidiary of General Electric Company This document is not intanded to be used for iasialiation purposes. we try to keep our Product inrormer�on up-to -date and accurate, We cannot cover A cpeciric apprications or an*ipale as requketnents. All speeircat;au•ere subject to diange pintail rwOce. For more WormatiM.00ntact 'f7w Clint UWV R44l. Haca Raton. FL 33431 ' . ► SecurityServicestinc. pbc_ (561)W&3W.F"- (561) 241-19n:. mode tim.uxi_ - OA45647 — Pagel oft Wiring of Standard Unit: ADT -BG -10 TO CONTROL PANE_ DETECTOR LOOP OUTPUT TO NEXT DEVICE OR E.L.R. Additional Switch Included With Model: ..BG -'t0A _ TO L__-- TERMINAL BLOCK FOR N.O. CONTACT FOR AUXILIARY FUNCTIONS Additional Switch (Key Operated) Included With Models: E3V^,,,- \ OP BG -1OT TO . TERMINAL BLOCK FOR TEST, OR TO PRESIGNAL CIRCUIT (KEY OPERATED) The BG -10SP PRODUCT LINE INFORMATION Model Description ADT- labeled standard unit Dual action. ADT-B G -10 Works with or without a crush tube. hcltxles a terminal block with screws for fast and easy wiring. -Standard urdt Plus as auxiliary N.0. 13G -10A switch to provide annunciator contacts. (Fire -ute labeled) SG -10T Standard unit plus key-test feature - (Fire-Lite labeled) BG -10P Standard uAt plus N.O. switch for pre - signal operation. (Fire•Llte labeled) ADT- BG -10L ADT-labeled standard unit plus key locking feature. Standard unit plus an awdfiary N.O. switch BG-10LA 0 provide annunciator contacts, plus key locking feature. (Fire -Lite labeled) Siardard unit plus weatherproofirg- B G -1 A W P hdudes surface watherproof box (WP -10). (Fire -lite labeled) Spanish version of standard unit SG -10S P Dual action. Wortcs W1h or Hrthout a crush tube. ktGtdes a terminal block (Fire -Ute labeled) WP -10 - Weatherproof surface•backbox.for BG 10WP (included with BG-10WP}. Surface -mount backbox for alf BG-10 models. BG 7e Optional trim ring. ARCHITECTURAVENGINEERING SPECIFICATIONS Manual Fire Aiarm Stations shag be non-coded, break -tube (or non -crush tube) type, with a key - operated test -reset tack (or Hex wrench reset) in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored ' to normal except by use of a key (or Hex wrench). An operated station shall automatically condition itself so as to be visually detected, as operated, at a minimum distance of lob feet (30.48 m), front or side. Manual Stations shall be constructed of LEXANO (or polycarbonate equivalent) with cie-arty visible operating instructions on the front of the stations in raised letters, 1.76' (44.45 mm) or larger. -Stations shall be'su'dable far surface mounting on matching backbox, or semi -flush mounting on a standard sing18 -gatig box, and shalt lie installed within the limits defined by the Americans with Disahgifies Act ({><pA) dependent on manual . ' statlon:"stbility or per,Jocai requirements_ Manual-Stations shall tie Underwriters Laboratories fisted. F P89e,2 or 2 — bA- 45647. D1256, D1257 Fire Command Center, Fire Annunciator Specifications Features • Compatible with the D9124, D9112, D9412, D7212 and D7412 • Attractive low profile fire annunciators • D1256 provides system control with easy to use function keys • D1257 can be remotely installed in public access areas • Built -in multi -tone sounder • Easy to read vacuum fluorescent display • Displays complete system status in English format • Programmable custom text for each point • Local system test display • Molded red ABS plastic construction Description Radionics' D1256 Fire Command Center and D1257 Fire Alarm Annunciator are four -wire serial devices used with the Radionics' D9124 Addressable 24 VDC Fire Alarm Control/ Communicator and the D9112, D9412, D7212 and D7412 Control /Communicators.One D1256 is included with the D9124 panel, which can be accessed through the slide door on the front of the enclosure. Both annunciators provide English text displays of system events with highly visible blue vacuum fluorescent displays. A built -in sounder alerts building personnel to system alarms and troubles and guides responding agencies to the annunciator location. Both units are molded in durable red plastic and have low profile enclosures. The wording "Fire Alarm Annunciator" is clearly printed on the faceplate of the D1257. This allows inspectors, service technicians and responding fire agencies to identify the annunciator. The D1256 Fire Command Center is a full- function system controller and annunciator. Four special one -touch function keys provide user - friendly control over the system. The function keys allow the user to silence the audible alarm output, silence the trouble sounder, reset the annunciator display and reset system detectors. Four additional navigational keys allow access to other programmed system functions. The D1257 Fire Alarm Annunciator provides remote annunciation capabilities without system control. Similar in appearance to a D1256 Fire Command Center, yet the D1257 Fire Alarm Annunciator lacks function keys. This makes system control functions inaccessible to unauthorized persons. Thus, the D1257 can be placed in locations where the public may have access to it. Two navigational keys allow the user to step forward or backward through a list of system events. radionics Fire Command Center and Fire Annunciator Application The D1256 can be mounted in secure areas for use as both a system controller and annunciator. The D1257 Remote Fire Annunciator is typically installed in building entrances and areas with unrestricted access. Near exterior doors in hotel or business lobbies are ideal locations. This allows a responding agency, or persons evacuating the building to quickly identify the type and location of the emergency from outside the building without being in danger. Both devices have a built -in sounder that allows them to be installed in locations not in general view. Audible tones alert personnel to fire system events and assist fire fighters in locating the annunciator. Installation The D1256 and D1257 system annunciators connect to the fire control /communicator through standard four -wire cable. Shielded cable may sometimes be required where excessive EMI is a problem. The field wiring connects to a four -wire harness supplied with the unit. This harness plugs into a four -pin connector on the circuit board through the back of the D1256 or D1257. Each unit has three mounting holes in the base that allow secure, correct positioning during installation. Do not install the D1256 or D1257 in direct sunlight. This damages the module components and makes the display less visible. Install, test and maintain these devices according to their Installation Guides, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the devices to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained. A member of the Bosch Group National Security Systems Inc (800)457 -1999 Description Wheelock's patented 2 -wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with less current draw and Zero Inrush. Strobe options for wall mount models include 15/75cd or Wheelock's patented Multi- Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. Ceiling mount models are available in 15, 30, 75 or 100cd intensities. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FRCP) is applied. Each tone has 3 dBA settings to choose from. Additionally, the audible may be silenced while maintaining strobe activation. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS- 12/24 -8 Power Supply with Wheelock's Patented Sync Protocol. Synchronization of the continuous horn tone provides the temporal (Code 3) tone as mandated by NFPA -72 for all audible appliances. This ensures a distinct temporal (Code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized, the temporal sound may overlap and not be distinctive. At the same time, the strobes will also be synchronized. This provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and NFPA and UFC standards when installing two or more visual appliances within the field of view. All of this, plus the ability to silence the audible is achieved by using only 2 WIRES. For Weatherproof Series AS, See ©atasheet S9004 Copyright 2002 Wheelock Inc. All rights reserved. SERIES AS SERIES AH Multi - Candela Indicator (bottom of lens) Features • Approvals include: UL Standard 1971, UL Standard 464, California .State Fire Marshal (CSFM), New York City (MEA), and Factory Mutual (FM) Pending: Chicago (BFP). • ADA/NFPA/UFC /ANSI Compliant. • Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or 110cd (Multi - Candela models) or 15175cd. • Weatherproof wall mount UL Listed for outdoor use (ASWP) • Ceiling mount models are available in 15, 30, 75 or 100cd. • Selectable Continuous Horn or Temporal (Code 3). • 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones. • Patented 2 -Wire Audible Strobe Appliance. • Patented Universal Mounting Plate. • Strobes produce 1 flash per second over the regulated voltage range. • 12 and 24 VDC models with wide UL "Regulated Voltage' using filtered DC or unfiltered VRMS input voltage. • Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS- 12124 -8 Power Supply with Wheelock's built -in sync protocol. • ZERO Inrush above Peak. • Compatible with all Wheelock 2 -Wire products. • Fast installation with IN / OUT screw terminals using #12 to #18 AWG wires. NOTE: All CAUTIONS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters. APPLYINGNTH S PRODUCT, READ ILURE SPECIFICATIONS AND ASSOCIATED Y WITH ANY OFT ESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT N IMPROPER OR APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes ,999 specifies a flash • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note {hat NFFA -72 (" ) P rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2 %). • Series AH 24 In are listed under UL Standard 464 for audible signal appliances (Indoor use only) erature ran e of 31 °F to 150 °F • Series AM -24WP audible appliances are listed under UL Standard 464 for indoorloutdoor use with a temp 9 ( -35 °C to 66 °C) and maximum humidity of 95 %. • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range ". fable 6: Average Current' (AMPS) for Ceiling Mount for 12 VDC and 24 VDC Series ASIAH 12 and 24 VDD Audible Table 5 Table 1: Ratings Per UL 1971 Anechoic dBA @ 10 ft. At the 3 Audible Settings @ 16, 24, Volume Regulated Voltage Strobe Candela (ad) Descrir Model input Voltage VDC Range VOCIFWR dBA Levels Models AS- 24MCW -FR 24 16.0 - 33.0 15130!751110 Canon AS- 241575W -FR 24 16.0-33.0 15 (75 on Axis) AS -2430C AS- 121575W -FR 12 8.0- 17.5 15 (75 on Axis) AS -2475C AS- 2415C -FW 24 16.0-33.0 15 Cod AS- 243OC -FW 24 16.0-33.0 30 AS -24150 AS- 2475C -FW 24 16.0 - 310 75 AS -24300 AS- 2410OC -FW 24 16-0-33.0 100 A8-2475C ASWP- 2475W -FR 24 16.0 -33.0 75a-31`F AS- 241000 .369 .258 .217 AS -2415C Table 2 Average Current -(AMPS) for AS-24 MC Wall Models @ Each Candela Setting .082 I Average Current -vi h High dBA Setting (99 dBA) , Average Current Voltage 15cd 30cd .095 75cd 110cd 332 16.0 VDC .095 .142 AS- 24100C 242 .'� .207 24.0 VDC .066 .120 .174 224 33.0 VDC .099 .i20 .152 .190 Average Currentwith Meditim dBA Setting (95 dBA) .061 .128 225 .296 .C68 .105 .157 207 .066 .030 .119 •157 unent-vrith Lew dBA Setting (90 dBA) M-Low .077 .119 222 .294 .0 60 .090 .142 200 .0:s .081 .109 .147 e Current' (AMPS) Table 4: Average Current ` (AMPS) & AH -12 -RN & WP Series AS- 241575 VOLTAGE High Medium Low qonly) h Medium tow 16.0 VDC .124 .108 .103 33 .0 19 .013 24.0 VDC .102 -083 .077 24.0 VDC .047 .025 .016 33.0 VDC .100 .077 .067 33 -0 VDC .066 .033 .020 8,0 VDC .989 .035 029 12.0 VDC .103 .047 .033 17.5 VDC 122 .066 .040 #ISM Sync Module is rated for 3.0 SYNC MODULES1 POWER SUPPLY amperes @ 24 VDC. Average ##DSM Sync Module is rated for 3.0 Input omen Current Moungng am eres er circuit. The maximum p p Model Member Code Voltage (AMPS) .@ options'- Woe) 24 VDC number of interconnected DSM mod is twenty (20). Refer to Data Sheet SM- 1224 -R• 6369 24 .026 w S3000 or installation Instructions PS for SM and P83177 for DSM. DSM - 1224 -R- 6374 24 .ws W ###Refer to Data Sheet S9001 or Installation Instructions P83862 for Psavzae °• 6na 120 vnc 12124 -8 Pourer Supply. fable 6: Average Current' (AMPS) for Ceiling Mount for 12 VDC and 24 VDC Series ASIAH 12 and 24 VDD Audible dBA Ratings Anechoic dBA @ 10 ft. At the 3 Audible Settings @ 16, 24, Volume Reverberant dBA .fan Valtago Per UL 464 @ 10 ft. dBA Levels Models 16.6 VDC High 91 99 ous Horn .130 Medium 88 95 AS -2430C .178 Low 83 90 AS -2475C .357 High 87 99 3 Horn .404 Medium 84 95 AS -24150 .116 Low 79 90 fable 6: Average Current' (AMPS) for Ceiling Mount 24 V Audiblo strata- At the 3 Audible Settings @ 16, 24, and 33 VDC Valtago dBA Levels Models 16.6 VDC 24.0 VDC 33.0 VDC AS -2415C .130 •106 .102 Average Current AS -2430C .178 .135 .131 with High dBA Setting (99 dBA) AS -2475C .357 P48 .200 AS- 24100C .404 .277 .245 AS -24150 .116 .091 .ors Average Current AS -24300 .164 .120 103 with Medium dBA Setting (95 dBA) A8-2475C •339 226 .179 AS- 241000 .369 .258 .217 AS -2415C .112 .082 .069 , Average Current AS -24300 ,160 - 113 .095 with Low dBA Setting (90 dBA) AS -24750 332 219 ,164 AS- 24100C .382 .252 .207 Table 71 Average Current' (AMPS) for Wan 15j'75 ca 12 V Audible Strobe At the 3 Audible Settings @ 8, 12, 8 17.5 Voltage dBA Level Model 8.0 VDC ST.O VDC 1 17.5 VDC 4dBA) unent 406 256 251 dBA AS- 121575W umrrent AS- 121575W .354 .217 .182 dBA) Cuno -1 162 dBA AS- 121575W .348 -194 ) * Average Current per actual Wheelock Production Testing at listed VDC. For Rated Average and Peak Iles current across UL Regulated Voltage Range for both 023 Filtered DC and Unfiltered VRMS, see Installation Instructions. {ions. *" Refer to Data Sheet S7000 for Mounting Op 'S- ASS WARNING: CAND CONTACT WHE) LOC FOR ( THE CURRENT Se s "INSTALLATION IN "GENERAL RMAilON" SHEET SERIES THESE PRODUCTS. THESE RTES DOCUMENTS UNDERGO PERIODIC IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TTO SPECIFYING ORIINSTALLING THESE PRODUCTS, INCLUDING: MATERIALS TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ' DRAW 70 INSURE THAT THE-TOTAL AVERAGE CURRENT AND TOTAL PEAK LA SETTINGS WILL REQUIRED BY A�LrAPPLIANCESN ODNOTyEXCEED LTHE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHI N THEIR "REGULATED VOLTAGE RANGE ". INSTALLATION OF lie CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. NC I COULD INSTALLATION, INSTRUCTIONS LT N PROPERTY DAMAGE Pp FAILURE TO COMPLY WITH THE INSTALLATION APPLICATION, AND OR OPERATION OF THESE PRODUCTS N AN EMERGE SITUATION, WHICH COULD RESU SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams" SERIES AS APPLIANCES NON - SYNCHRONIZED FROM TO NEXT PRECEDING +— ±APPLIANCE APPLIANCE OR EOLR OR FACP SERIES AS APPLIANCES SYNCHRONIZED WI DSM MODULE CLASS "A" NAC CIRCUIT W1 NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WI SM MODULE SINGLE CLASS "B" NAC CIRCUIT W/ AUDIBLESILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED W1 MULTIPLE DSM MODULES SM STROBE F STROBE y. STROBE DSM 91 3lrobe SYNC A NAC AS AS Circuit CIRCUIT C�AUdlOte Strobe NAC Cb. 0 r` AS AS OUT EOLR -OUT 1 Audible Audible 0 - t NAC I Circuit AS SERIES AS APPLIANCES SYNCHRONIZED W1 MULTIPLE DSM MODULES Series P5- =T ti # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the PS- 12124 -8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used Within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). DSM STROBE y. DSM 91 NAC SYNC Audible NAC Cyr, CIRCUIT Strobe NAC Cb. 0 r` AS AS OUT -OUT 1 F 0 - t I IN 1 AS AS AS \ DSM f!2 Audible NAC eir A Sy— MINUS I Strobe NAC Cir A$ AS FACP I rA- JD C 0- Audible NAC Ci DSM ri3 r,IINUS 2 rj P Syn c AS AS AS Strobe NAG Cif. �+ +IN2 AS AS STROBE +OUT2 DSM Interconnectingwtring shown. Maximum of NAC twenty (20) CIRCUIT RETURN APPLIANCES SYNCHRONIZED Wf PS- 12 -24 -8 SERIES AS 8r RSS OUTPUTS PS EOLR nf ;.CLASS B OR AS PSS 2LLA S5 Series P5- =T ti # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the PS- 12124 -8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used Within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Enaineers Snecifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible Strobe shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing - Impaired) for Indoor Fire Protection Service- The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). The audible /strobe shall be listed for indoor use and both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FRCP). - - The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design and shall have Zero Inrush. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL Standard 1971 for: 15, 30, 75 or 110 candela. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15175 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). For ceiling mount applications, the strobe intensity shall be 15, 30, 75 or 100 candela. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS- 12/24 -8 Power Supply with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while main- taining strobe activation. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. if required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Sbecifications and Orderina Information Model Order code Strobe Candela Non -Sync Sync wISMs, DSM or PS- 12124 -8 24 VDC 12 VDC Wall Mount Ceiling Mount Mounting options' AS- 24MCW -FR 9024 15!3017 5/ 1 1 0 X X X X A B,D,E,F,G,H,J,hl,O,R,X AS- 24MCW -FW 9025 15!30175111D X X X X A,B,D,E,F,G,H,J,N,O,R,X AS- 241575W -FR 7405 15 (75 on Axis) X X X X A,B,D,E,F,G,H,J,N,O,R,X AS- 121575W -FR 7410 15 (75 on Axis) X X X X A B,D,E,F,G,H,J,N,O,R,X AS- 2415C -FW 7411 15 X X X X A, B,D,E,F.G,H,J,N,O,R,X AS- 2430C -FW 7412 30 X X X X A B,D,E,F,G,H,J,N,O,R X AS- 2475C -FW 7413 75 X X X ; X A B,D,E,F,G,H,J,N,O,R,X AS- 2410OC -FW 7414 100 X X X X A,B,D,E,F,G,H,J,N,O,R,X ASWP- 2475W -FR" 9012 75 @ -31 -F X X X X I (see Data Sheet S9004) AH -24-R 7892 X X X X X A B,D,E,F,G,H,J,N,O,R,X AH -12 -R 7891 X X X X X A,t3,D,E,F,G,H,J,N,O,R,X AH- 24WP -R° 7416 X X X X X K AH- 12WP -R° 7415 X X - X X X K *Refer to Data Sheet S7000 for Mounting Options. "For Weatherproof Series ASIAH specifications see data sheet S9004. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY NATIONAL SALES OFFICE Made in USA Distributed By: 1- 800 - 631 -2148 Canada 800 397 -5777 -� E -mail Info @wheelockinc.com$ htt / /www wheefockinc com i MM I ; WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732 -222 -6880 • FAX: 732- 222 -2588 S6100 11102 Fire Alarm Systems ��P��RiNG FIRE' A Family of Mult- Candela Appliances DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw and Zero Inrush while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 151715 and 185cd or Wheelock's patented. Multi - Candela strobe with field selectable candela settings of: 15, 30, 75, 6r 110cd. Ceiling Mount models are available in 15, 30, 75, 100, 150, and 1 77c intensities. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS- 12/24 -8 Power Supply with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72 (1999). Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. if the flush backbox has side or top space between i. and the finished wail, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided fora clean, finished appearance on all models. The Series RSSP Multi- Candela Strobe Plates are a cost effective way to retrofit required strobe appliances to bells, homs, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2001 Wheelock, Inc. All rights reserved. Helping People Take Action'" SERIES RSS & RSSP SINGLE & MULTI- CANDELA STROBES & STROBE PLATES Series RSS Series RSSP Features Approvals include: UL 1971, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual, Chicago (BFP). High Candela Approvals: UL 1971. Pending: MEA, :. Factory Mutual, BFP, and CSFM. ADA/NFPA/UFC /ANSI compliant. Meets OSHA 29 Part 1910.165. Wall mount models are available with Field Selectable Candeia Settings of 15, 30, 75 or 110 cd. (Multi - Candela models) or 15nS, and185 cd. Ceiling mount models are available in 15, 30, 75 100, 150 and 177 cd. Low current draw with temperature compensation to reduce power consumption and wiring costs. Strobes produce 1 flash per second over the regulated voltage range. 12 and 24 VDC models with wide New UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage. Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS- 12124 -8 Power Supply with Wheelock's built -in sync protocol. ZERO Inrush above Peak. Compatible with all Wheelock 2- Wire products. Fast installation with IN /OUT screw terminals using #12 to #18 AWG wire. NOTE_ All CAUTIONS and WARNINGS are identified by the symboA . All warnings are printed in bold capital letters. BWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYrNG THIS PRODUCT, FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLAMN ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. Genera[ Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA -72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL 1971. and Series RSS & RSSP Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) maximum humidity of 93% (t 2%). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, U used the terminology "Listed Voltage Range ". Table 1: Specifications & Ordering Information - MuidCandeia and Single Candela Models - WALL MOUNT Model - Order Code Input Voltage VDC Regulated Voltage Range VDCIFWR RSS - 24MCW -FR v 9400 24 16.0-33,0 RSS- 24MCWFW 9401 24 16.0. 33.0 RSS- 241575W -FR 7471 24 16.0 -33.0 RSS- 121575W -FR 7476 12 8.0 -17.5 RS S P- 24 MCW- F R 9402 24 16.0 - 33.0 RSSP- 241575W -FR 7793 24 16.0-31.0 RSSP- 121575W -FR 7798 12 H.0 - 17.5 RSS- 24185W -FR "'" 8223. 24 16.0-33.0 "`RSS- 24185W -FR is for future release... Table 2: Specifications & Ordering Information - Single Candela Ceiling Mount Average Current' 0 24 VDC Code Strobe Candela (CD) 15cd 30cd 75cd 110cd Mounting Options " 15!30/75!110 .050 .081 .133 .161 B4O,E,F,GH,J,N.O.R,X 15201751110 .050 .081 .133 .161 B, D, E.F,GH,J,N.O,R,X 15 .072 B4O,E,F,GH,J,N,O,R,X 15 (75 on Axis) .065 24 16.0 - 33.0 30 B,D,E,F,GH,J,N,O,R,X 15 (75 on Axis) .170 7484 15130!751110 .050 .061 .133 161 D,E,Z 15 (75 on Axis) .065 D,E,Z 15.(75 on Axis) .170 D.E,Z 185 i ..293 A.B,C,D Table 2: Specifications & Ordering Information - Single Candela Ceiling Mount Model Code Input I Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candek Average Current' Mounting Options ' RSS- 2415C -FW 7482 24 16.0- 33.0 15 .072 B,D,E.F,GHJ:N.O,R.X RSS - 24360 -FW 7483 24 16.0 - 33.0 30 .102 B,D.E,F,GHJ.N.O,R,X RSS- 2475C -FW 7484 24 16.0- 33.0 75 .205 B,D,E.F,GHJ.N.O.R,X RSS- 241001 7485 24 16.0-33.0 100 238 B,D,E,F.G,HAN,O.RX RSS 241500 -FW 8222 24 16.0 - 33.0 150 .293 A,B,C,D RSS- 24177C•FW 8230 24 16.0-33.0 177 .333 A,B.C,D SYNC MODULES 1 POWER SUPPLY Average Order Input Voltage Current Mounting Model Number Code (VDC) (AMPS) C Options" 24VDC SM I?J24 -R 6369 24 .025 W DSM - 12!24 -R1' 6374 24 .038 N1 PS- 12124 -8 — 8114 120 VAC # SM Sync Module is rated for 3.0 amperes @ 24 VDC. ## DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet 53000 or Installation Instructions (P83123) for SM and P83177 for DSM). # ## Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 121248 Power Supply. ' Average Curren( per actual Wheelock Production Testing at Listed VDC. For Rated Average and Peak current across UL regulated voltage range for both Filtered DC and unfiltered VRMS, see installation Instnrctions. " Refer to Data Sheet 57000 for Mounting Options Table 3: Audibles/Speakers for RSSP Str_ obe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH Motor Bells MB- G6 /G10 Speakers ET-101011080, E70, ET-70 Chimes CH70 ,&WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (Pa3911) SERIES RSSIRSSP- 24MCW, (1384022 AND P84025) SERIES RSSIRSSP SINGLE CANDELA AND - GENERAL INFORMATION" SHEET (P823W) ON THESE PROOUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES - IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS, THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUFfS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING� REPLACING OR DRAW O INSURE THAT THE TOTALAVEERAGE CURRENT AND TOTAL PEAK REQUIRED BYALL APPTLJANCEES DO NOT DRAW. THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. - COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE " - INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH - FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATK}N PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS- Wirhw Diagrams # - SERIES RSSIRSSP APPLIANCE FROM TO NEXT PRECEDING- STROBE STROBE + APPLIANCE APPi1A11C NC E, SY A OR EOLR MODULE, POWER Circuit SUPPLY OR FACP SERIES RSSIRSSP APPLIANCES SYNCHRONIZED W1 DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE �� - —NAC- -SYNC _ - CIRCUIT ITROBL G, •purl RSS RSS RSS MINUS 1 MINUS 2 .:N2 RSS RSS RSS 0 -OUT NAC CIRCUIT RETURN TO NEXT r-ROM 4 APPLIANCE PRECEDING OREOLR STROBE /PLATE APPLIANCE• SYNC ` MODULE. POWER ASSEMBLY SUPPLY OR rACP O AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON + f f - -1( - -- - -- +�w STROBE/PLATE ASSEMBLY +- m +• AUDIBLE & VISIBLE APPLIANCE STRost APPLIANCE OPERATE INDEPENDENTLY SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WISM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F STROBE STROBE — �J A NAC NAC Circuit C 7 ,Autlibl V(%� P ~� EGLR Y'A01bl 1 SERIES RSSIRSSP APPLIANCES SYNCHRONIZED_ t W[MULTIPLE DSM MODULES DSM 11 DSM Interconnecting wiring shown- Maximum of I twenty (20) Sl SERIES RSSIRSSP APPLIANCES SYNCHRONIZED W/ PS- 12(24 -8 5e, P -1T124 8 COLA OUTPUTS F C1 A55 B A OR AS 1355 C 2 -CUSS P Seder PS -M1 L24�8 # For detail using SM or DSM Sync Module refer to Data Sheet S3000 Or installation instructions (P83123 for SM and P8311 i Tor UZ:lm). For wiring information on the PS- 12124 -8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied. installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance With focal, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), focal, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be fisted for LIL Standard 1971 (Emergency Devices for the Hearing Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) Flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® tens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design and shall have Zero Inrush. Where wall mount, Multi- Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL 1971 for: 15, 30, 75 or 110 candeta- The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15175 candela strobe shall be specified when 15 candela UL 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). For standard ceiling mount applications, the strobe intensity shall be 15, 30, 75, or 100 candela - For high intensity wall mount applications, fumish RSS- 24185W for 185cd applications- For high intensity ceiling mount applications provide RSS- 24150C for 150cd applicaitons or RSS- 24177C for 177cd applications. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS- 12/24 -8 Power Supply with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single -gang, double-gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi. Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terns and conditions. SPECIFICATION AND ORDERING INFORMATION Model Order Code Wall Mount Ceiling n g Mount .Non- Sync Sync wl I SM,DSM or PS 12/248 Strobe Candela 24 VDC 12 VDC # Model color , RED # Model Color WHITE RSS - 24MCW -FR 3400 X. X X 15(30(751110 X X RSS- 241575W R 747.1 X - - -X X - 15 (75 on Axis) X X RSS- 12.1575W -FR 7475 X X X 15 (75 on Axis) X X RSS- 241SC -FW 7482 X X X 15 X X RSS- 2430C -FW 7483 X X X 30 X X RSS- 2475C -FW 7484 X X X - 75 X X RSS- 241000Fw 7485 X X X 100 X X RSSWP- 2475W -FR- 9013 X -X X 75 ce -31 F X X RSSP- 121575W -FR 7798 X X X 15 (75 on Axis) X X RSSP- 24MCW -FR 9442 X j X X 15130x751110 X X RSSP- 241575W -FR 7793 X, X X 15 (75 on Axis) X RSS- 241SOC -FW 8222 X X X 150 X X RSS- 2417.7C -FW 8230 X X X 177 X X RSS- 24185W -FR-- 8223 X X X 185 X X # Models are available in either Red or White- Call Customer Service for Order Code & Delivery. 'For Weatherproof Series RSS Strobe specifications see data sheet 59004. - 'RSS- 24185W -FR is for future release. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION_ 3 YEAR WARRANTY Made in HSA NATIONAL SALES OFFICE 1- 800 -631 -2148 Canada 800 397-5777 E-mail: Info@wheelockinc.com hUp Wwww -wh eelockinc -com Distributed By: WHEELOCK, INC. - 273 BRANCHPORT AVE -LONG BRANCH, N.J. 07740- 732 - 222 -6880 • FAX: 732- 222 -2588 SO410 03/02 u1h¢e3ock • - A '. , , u 4'A11t MEA � .. .. �. � � �. . P re,tilarm Systems Help ng Cpl T e Act, on DESCRIPTION: Wheelock's Weatherproof Strobe, Audible Strobe, Audible Horn and Multitone Strobe appliances have an extended temperature range of -31'F to 150 -F ( -35C to 66'C) that wil:.satisfy virtually all outdoor and severe environment applications. All strobes are Indoor /Outdoor UL 1638 Listed and rated for 75 candela @ -31•F (- 35 -C). The Wheelock Weatherproof Appliances are designed formaximumperformance, reliability, and cost effectiveness while meeting or exceeding the latest requirements of NFPA 72 (National Fire Alarm Code), UL Standard 1638 (Standard for Visual Signaling Appliances), and UL 464 (Standard for Audible Signaling Appliances). Series RSSWP Strobes, Series ASWP Audible Strobes and Series AHWP Audibles may be synchronized when used in conjunction with the Wheelock SM and DSM Sync Modules or the PS- 12/24 -8 Power Supply with. Wheelock's Patented Sync Protocol. The Series MTWP is a true 4 -wire appliance. The strobe portion can be synchronized as stated above. The multitone portion cannot, but it can be connected to a coded fire alarm system. Weatherproof Strobe Series RSSWP Is UL 1638 approved for indoor /Outdoor use. The appliances use a Xenon ftashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum visibility and reliability for effective visual signaling. The Series RSSWP mounts to a Series WPSBB Weatherproof Backbox. Weatherproof Audible Strobe and Audible Series ASWP and AHWP is UL 1638 and UL 464 approved for Indoor /Outdoor use and offer a field selectable choice of continuous horn ortemporai pattern (Code 3) when constantvoltage from the Fire Alarm Control Panel (FACP) is applied. Additionally, the audible has three (3) selectable dBA settings of 99, 95, and 90 dBA in both tones and, when synchronized, may be silenced while maintaining strobe activation. The Series ASWP mounts to a WPBB Weatherproof Backbox while the Series AH mounts to a WBB_Weahterproof Backbox, Weatherproof Multitone Strobe and Multitone Horn Series MTWP and MT- 12124 Is UL 1638 and UL 464 approved for Indoor /Outdoor use and offers a field selectable choice of 8 nationally and internationally recognized alerting signals. Additionally, the audible has 2 installer selectable sound output levels: Standard and high covering a range (depending on selected signal) of76 -94 dBA reverberant. The Series MTWP is a true 4 wire appliance. The Strobe portion can be synchronized or non - synchronized. The multitone (audible) portion cannot be synchronized, but it can be connected to a coded fire alarm system. The Series MTWP and the MT -12124 mount to a series IOB Backbox. Ccavmht 2002 Vehaaiock Inc. A11 rbht5.rvWNveU. SERIES RSSWP, ASWP, AHWP, MTWP and MT -12124 WEATHERPROOF STROBE WEATHERPROOF AUDIBLE STROBE AND WEATHERPROOF AMBLES SERIES MTWP Mounted to JOB -R SERIES RSSWP Mounted to WPSBB -R SERIES AHWP Mounted to WBB -R SERIES ASWP Mounted to WPBB -R t. FEATURES Approvals include: UL 1638, UL 464, California State Fire Marshall (CSFM) and New York City (MEA). Pending: MEA on MTWP, Factory Mutual (FM) on MTWP and RSSWP and Chicago (BFP). • Designed to meet or exceed NFPA, UFC, ANSI 117.1, OSHA Part 29, 1910.165, and ADA requirements. • UL 1638 and UL 464 listed with extended temperature range of -31 ° to 150 °F ( -35 °C to 66 °C) • 24 VDC with new UL "Regulated" Voltage Range. of 16 -33 VDC using filtered DC or unfiltered FWR voltage. Note: The Series MT -12/24 voltage range is 10.5 - 15.6 VDC (for 12V) and 20 -31 VDC (for 24V). Sync /Non -Sync in each product. Note: The audible portion of the Series MTWP and MT -12/24 is non sync only. Synchronize with Series SM, DSM Sync Modules or PS- 12/24 -8 Power Supply with built -in patented sync protocol Selectable dBA settings. • Selectable alert signals. • IN and OUT wiring termination that accepts two #12 -18 AWG wires at each terminal • Inputs are polarized for compatibility with industry standard reverse polarity supervisor. Table 6: Average Current' (AMPS) for Series MT -12/24 and audible of MTWP Tone 12.0 VDC 24.0 VDC Standard High Standard - High Horn D.020 0.100 0.023 0.040 Belk 0.010 0.031 0.012 0.014 March Trr>c 0.020 0.100 0.023 0.040 Cafe 3 Hom 0.020 0.100 0.023 0.040 Code 3 Tone 0.015 0.060 0.017 0:026 Slow Whoop 0.025 0.100 0.026 o-W Siren 0.020 0.082 0.023 0.036 HVLo 0.012 i 0.044 0.014 0.020 IT -mow A Q A P�+i- fnr SPriPa M-TWP and MTA2124 Tone Standard MTWP MT -12124 Strobe Cardeia Per UL 1638 High Setting 18.0 VDC 24.0 V DC 33.0 VDC 20.0 VDC 24.0 VDC 10.5 VDC 12.0 VDC Horn Standard 84 87 90 82 85 82 85 24 High Setting 89 92 94 88 91 88 91 Bell Standard 76 80 83 75 79 75 79 High Setting 83 86 88 82 82 85 March Time Standard ; 80 84 87 79 !79 79 82 High Setting 86 89 91 85 85 88 Code 3 Hom Standard 79 83 86 75 75 79 High Setting 85 88 90 85 85 85 85 Code 3 Tone Standard 76 80 82 75 75 High Setting 81 88 85 79 82 T57 Slow Whoop Standard 81 85 87 82 82 High Setting 87 90 92 88 88 Siren Standard 81 84 87 82 82 82 82 High Setting 86 89 92 8S 88 85 88 HVLo Standard 77 81 84 78 79 79 79 High Setting 83 86 89 62 85 82 85 Table 8. UL Ratings Model Nominal Voltage (VDCNRMS) Regulated lnpui (VDC) Strobe Cardeia Per UL 1638 ASWP -2475W JAH- 24 16.0 -33.0 75 12WP -R 12 8.0 -17.5 - AI- -24WP -R 24 16.0 -33.0 12124 RSSVVP -2475W 24 16.0 -33.0 75 MTWP -2475W 24 16.D -33.0 75 MT- 12/24. 24 20.0 -31.0 - Table 9: SYNC MODULES / POWER SUPPLY PS- 12124 -8 ### 1 120 VAC ` . # SM Sync Module is rated for 3.0 amperes @ 24 VDC. ## DSM Sync Module is rated for 3 -0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). #H# Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12124 -8 Power Supply. Average input Current Model Number Voltage (AMPS) (VDC) 24 vac SM-1 2124-R # 12124 .028 DSM-11 2/24-R #4 12124 .038 PS- 12124 -8 ### 1 120 VAC ` . # SM Sync Module is rated for 3.0 amperes @ 24 VDC. ## DSM Sync Module is rated for 3 -0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). #H# Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12124 -8 Power Supply. Wiring Diagrams SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP - g SYNC 0 0 Strcbs e TO THE NEXT mod Nacre cr APPLIANCE PS12124 -8 ra A b OR EOLR pawK FACP NAC* SERIES RSSWPIASWP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE 0 NAC SYNC m CIRCUIT OUT 4ou11 r —� +IN 1 F ILII NUS 1 FACP O +AUaBIE M.,NUS z r NAC CIRCUIT RETURN I SERIES RSSWPIASWP APPLIANCES SYNCHRONIZED WIMULTIPLE DSM MODULES CLASS "B" NAC CIRCUITS DSM #1 Strobe NAC F A Strobe N DSM #3 P Sync } RSSKY RSS'r!P Strobe NAC Gtr. DSM Interconnecting wiring shown. Maximum of twenty (20) w heelock ,NC.. Helping People Take Actions"' Description: Wheelock Series SM & DSM Synchronization Modules provide - - the ability to synchronize the strobe flashes and the code 3 temporal evacuation alarm produced by Wheelock notification appliances. They also provide the ability to silence the audible alarm while maintaining the strobe flashes over a single pair of wires. Features: • 3 ampere per circuit current handling at 12 or 24 VDC • Low operating current draw Series SM & DSM Specification and Ordering Information j Order Model Number Input Voltage Average Current UL Max* Mounting Code i VDC @ 12 or 24 VDC AH -24WP Options SM- 12/24 -R 636 12 .017 0.023 W i 24 .028 0.038 W j DSM- 12/24 -R 6374 12 .020 0.026 W j 24 .035 0.055 W Sync Capability (With SM, DSM, PS- 12/24 -8CP or PS- 12/24 -8MP) Model Audible AH -12 Yes AH -24 Yes AH -12WP Yes AH -24WP Yes AMT- 241575W No AMT- 241575W -FR -NYC No AMT -24MCW No AS- 241575W Yes AS -24MCC Yes AS- 24MCCH Yes AS -24MCW Yes AS- 24MCWH Yes ASWP -2475W Yes CH70- 241575W No CH7024MCW No CH7024MCWH No CH90 -24MCC No CH90- 24 MCCH No _ E50 -24MC W Yes E50- 25MCWH Yes E50- 241575W NS- 241575W E70- 241575W Yes " E70 -24MCW Yes E70- 24MCWH RSS- 241575W - E90 -24MCC Yes E90- 24MCCH ET70- 241575W RSS -24 MCC ET70 -24M CW Yes ET70- 24MCWH ET70WP -2475W RSS -24i C=HR ET80- 241575W Yes _- ET80 -24MC W ET80- 24MCWH RSS -24MCW ET90 -24MCW Yes ET90- 24MCWH Strobe Model Audible ET90 -24MCC ET90- 24MCCH HS -24 Yes HS4- 241575W Yes Yes HS4 -24MCW Yes Yes HS4- 24MCWH Yes Yes MIZ -24S Yes Yes MT- 121575W No Yes MT- 241575W No Yes MT -24MCW No Yes MTWP -2475W No Yes NH -12124 Yes Yes NS- 121575W Yes Yes NS- 241575W Yes Yes NS -24MCW Yes Yes RSS- 241575W Yes RSS- 121575W Yes RSS -24 MCC Yes RSS - 24MCCH Yes RSS -24i C=HR Yes RSS- 24MCCR Yes RSS -24MCW Yes RSS- 24MCWH Yes RSSP- 121575W Yes RSSP- 241575W Yes RSS P -24MC W Yes RSSP - 24MCWH Yes RSSWP -2475W Yes S8 -24MCC Yes SS- 24MCCH Yes SA -S70 -24MCW Yes SA -S90 -24MCC Yes SA -S90 -24MCW Yes STH -MCCH Yes Key: - = Not Applicable to model Strobe Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 06/05 r J� Is. L P R 0 D U C T s I N F O R M A T 1 O N • Intelligent, self - diagnostics • On -site maintenance alert • Field replaceable optical chamber • Low - profile design • Plug -in terminal block • Advanced false alarm immunity B U L L E T I N 449/448 SERIES Four- Wire, Smoke aeteetors Model numbers: 449AT, 449C, 449CT, 449CRT, 449CST, 449CSTE, 4A9CSRT, 449CSRH, 449CTE CLC LtsrFn �.P..ovrD Cakfomia State Fire Marshal Approved MEA (New York City) Approved ULC model numbers, "BAT, 448C, 448CT, 448CST, 448CSRH, 448CTE The ESL 449/448 Series self- diagnostic, four -wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This unique, patented technology meets NFPF 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self - diagnostic routine and provides visual indication of sensitivity level, or if — service is require This series is easily cleaned by sirnpiy repiacing ESL's proprietary field- replaceable optical chamber. All models are designed to reduce false alarms from dust, insec -s. RFI, and external light. c binatl e ui -; is:- �r`t ; " ,,-:i '--foot "ez" per"C' ;c �:vc;•.i - r. with all "T' model detectors (see selection guide), allowing latching of the a!ar^, for either smoke or heat. The 4 =9CSRH inc. -,des an isolated alarr1 output for r,�at and acti%Ztes an internal non - latching sounder (Ic :al a!arm) fer EmOVe. mat: no it ideal for ESL 449 Series Smoke Detectors Architectural and Engineering self-diagnostic, �our -wire The ESL 449 Series low-profile, smoke detectors work on the light scattering principle. A pulsed infrared light- emitting diode serves as the light source, and a high -speed photodiode as the sensing el e reaches the the amount of light reflected onto the p rae increases. Three sensitivity setting, the smoke sampling (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects. RF and ambient - light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the alarm relay to operate. A trouble indication is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing requirements. An internal 85 d8 hcrn (available in -S' models) emits a temporal 3 when the detector alarms and a steady tone when power polarity is reversed. Product Data 3.1 - 1.0 % /ft. (max.) Sensitivity - -- -- ......' '-. "-- ..._. -' -. "' " ......... 3 1 + 0.50 % /ft- (min) 32 -F to 120 °F (0 °C to 50'C). . Operating temp. range ........ ..... 0 to 95 °!° RH Operating humidity range ...... •----------------------- - CT, CRT, CST, CSRT, CSRH , Minimum voltage - C, 8_5V - CSTE - - - -- -- - - - -- ------------•------•-•----------•-•------------ - ..... - - -- 5.1 V --- ---- -- Maximum voltage - C, CT, CRT, CST, CSRT, CSRH, 33V - -- ....... 27V - AT - -- ------- - - - --- ---- -- - -- --- ----- --- ------ --- -- -- -- --- -- Maximum ripple (peak to peak) --- - - - - - I —.... - - - - -. - --- 10% 0µA Typical average standby current .._ - . . . 2 3mA - CSTE ----- --- - -- --------- - ---- - - -- - - Typical alarm current - C, CT and AT .-- .-- - - - - -- -- -. 31 mA ------------- -- - -- - CRT ...- . . .......... . ... - - Selection Guide The proprietary optical sensing chamber is field replaceable_ allowing quick and easy cleaning and ved for releasing Models with auxiliary relays are app service. with a hinged cover, a This low profile product is equipped concealed tamper-resistant plug-in, (clamp -type screw temninais. Wiring terminates in Detectors mount to a standard single gang electrical box, a tour -inch octagonal, four -inch square electrical box, or WIREMOLD 5739 fixture box. Smoke Detector Spacing of 3p feet On smooth ceilings (as defined in NFPA 72), spacing used (9.1 meters) may be used as a duide: Other spacing may be depending on cerTing height, high air movement, and other n nr mcnonsP reouirements ° 40MA CST ..---- •-- •-- -- "----- - ----- ------ -- -- -- --- - - -... ...... 51mA - CSRT, CSRH, CSTE --------------------------------- ............ . .- •------ - - - - -- Typical avg. polarity reverse current 10mA - CST, CSRT, CSTE, and CSRH -_--------------------85-- dB at 10' Sounder specifications ... --------------- Heat detector specifications 135 °F (57-2'C) fixed temperature --- - - - - -- rate of rise - - -- 15°F /m'n- & >105'F (8.3'C /min. >40.6'C) Auxiliary relay contacts 2A C 28 VDC or 120 VAC (resistive) 500 mA @ 36 VDC (resistive) Alarm contacts ... 14 - 24 AWG Field wiring size ... ...... ..__. -..... e_1_e_..-- --- -.. . Packaging ....._ ................ 10 detectors White cover /( white base Color ... _ .. .. . . .... ......... v ✓ith UV inhibitor to prevent yellowing. Listing ............. ............... UL 268, ULC Fh4, CSFM and MEA Description rode entlyinps.theLFlZar� - -- :signato Feature detedx P� H asolated Fixed Temp: - lsolated�viced 135°F-- (57 °C)and rate�f.rise heat alarm and Rate of Rise output. Smoke detector activates iniemal sounder (locaha ?� ) and dsystem heat detector Heat Detector does not la does os 9 ^�w Ideal for hotel, motel and dormito y rooms `Were smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall, door he dens, strobes, etc. Listed for releasing servicF. �.. J;a . is 5 ated Fixed Temp. and Rate of rise Heat Detector E 3uili -:n end of line Fr supervision relay 85d8 is de Intergrated Fixed 135-F (57C) tempe2ture and rate of rise r ct at deteor. Either heat detector or smoke detector can tnp and latch LED and alarm protection - relay outputs. Relay is normally energ¢ed and will trip fJ� loss o! po:, er Czn also provide not f caftan when detector needs n,air�;enznce inter ( o g i ►• PH 507 692 4052 Ulf. ( C-61 I- Models Available DH400ACDCI Ionization Duct Smoke Detector DH400ACDCA Ionization Detector, ULC Listed DH400ACDCP Photoelectronic Duct Smoke Detector Features • 24 VAC /DC or 120 /220 VAC operation detector heads allow easy removal for quick cleaning and • Simple change -out of photo or ion detector heads maintenance, or a change in application without removing • Air velocity rating from 500 to 4000 FPM the duct housing. The DH400ACDC samples air currents • Powered outputs for remote LED and sounder passing through a duct and gives dependable performance • Remote test station option for management of fans, blowers, and air conditioning • Remote sounder option systems. • Equipped \•vitli a DPDT auxiliary relay (two Form C contacts) WARNING: Duct smoke detectors have specific limitations. • Easy and quick mounting to round or rectangular ducts DUCT DETECTORS ARE: from 1' - 12' wide NOT a substitute for an open area smoke detector, • Clear cover for convenient Visual inspection NOT a substitute for early warning detection, and • UL 268A listed NOT a replacement for a building's regular fire • 3 -year warranty detection system. System Sensor DH400ACDC 4 -wire duct housing will accommodate either the 1451DH ionization sensor or the Refer to NFPA 72 and 90A for additional duct detector 2451 photoelectronic sensor. The twist -in, twist -out application information. Specifications Length: 14.5 inches (37 cm.) Operating Width: 5 inches (12.7 cm.) Humidity Range: 10% to 93% relative humidity Depth: 4 inches (10.2 cm.) Air Duct Velocity: 500 to 4000 ft. /min. Weight: 4.5 lbs. (2.0 kg.) Operating Temperature Range: 32° to 120 117 (01 to 49 °C) L FM MEA �„ l� `•': ® approved r''RVc APPROVED 'D S��stem Sensor 8/96 this doctiment is not intended to be used for installation purposes. A05-201-02 Architectural /Engineering Specifications The air duct smoke detector shall be a System Sensor incorporate an airtight smoke chamber in compliance with Model DH400ACDC Series Duct Smoke Detector. The UL 268A, Standard for Smoke Detectors for Duct detector housing shall be UL listed per UL 268A Applications. The housing shall be capable of mounting to specifically for use in air handling systems. The detector either rectangular or round ducts without adapter shall operate at air velocities of 500 feet per minute to brackets. An integral filter system shall be included to 4000 feet per minute. The detector housing shall tie reduce dust and residue effects on detector and housing, equipped with an integral mounting base capable of thereby reducing maintenance and servicing. Sampling accommodating either photoelectronic or ionization tubes shall be installed after the housing is mounted to the detector heads. It shall be capable of local testing via duct by passing through the duct housing. Terminal magnetic switch or remote testing using the RTS451KEY connections shall be of the strip and clamp method Remote Test Station. The duct detector housing shall suitable for 14 -1S AWG wiring. -� CONDUIT HOLES FOAR1 ---. U INLET SAr,IPLING TUBE GASKETS (BUFF /UED SEPARATEL =� TUBE �1 END, N // PLUG.) I, -, O RINGS / f . I � 1 DETECTOR BASE HOUSING --- - -' f, MOUNTING SCREWS EXHAUST FILTER ADAPTER 1 I 1 DETECTOR HEAD — - -- Exploded View of DH400ACDC Duct snr:fPUNG TUBE Detector Components L TEST MAGNET FII TERS Electrical Ratings - DH400ACDC - DUCT DETECTOR HOUSING -- PC BOARD INSULATOR o\ DUCT DETECTOR COVER / 9 j Power Supply Voltage I 20 - 29 VDC I 24 VAC 50 - 60 Hz I 120 VAC 50 - 60 Hz I 2201240 VAC 50 - 60 Hz VVRRCIVI RCV UInLIVILIV1J �v.�i�v.� ...............,•,- SAMPLING TUBE f \ - MOUN T NG MOUNTING - -- SCREIP!S -. 25 mA­� 35 mA RMS 20 mA RMS 20 mA RMS 9 j Power Supply Voltage I 20 - 29 VDC I 24 VAC 50 - 60 Hz I 120 VAC 50 - 60 Hz I 2201240 VAC 50 - 60 Hz VVRRCIVI RCV UInLIVILIV1J �v.�i�v.� ...............,•,- 25 mA­� 35 mA RMS 20 mA RMS 20 mA RMS Max. standby current 96 mA 55 mA RMS 55 mA RMS 30 mA RMS Max. alarm current CONTACT RATINGS Alarm initiation contacts (SPST) 2.OA @ 30 VAC /DC (0.6 power factor) Alarm auxiliary contacts (DPDT) 10A @ 30 VDC 10A @ 277 VAC (0.75 power factor) 240 VA @ 240 VAC (0 4 power factor) 1/8 HP @ 120 VAC 1/4 HP @ 240 VAC Trouble contacts (SPST) 0.3A @ 32 VDC (resistive) I ACCESSORY CURRENT LOADS AT 24 VDC DEVICE STANDBY ALARM APA451 12mA MAX 30mA MAX PA400 Om 15mA MAX RA40OZ OmA 7mA MAX RTS451KEY OmA' 7mAMAX' ANY COMBINATION OF ACCESSORIES MAY BE USED SUCH THAT THE GIVEN CURRENT LOADS TOTAL: 1 00m OR LESS IN THE STANDBY STATE, 150mA OR LESS IN THE ALARM STATE. 'NOTE: WHEN INITIATING AN ALARM. THE RTS451 REOUIRES71mAMAXIMUM IN PRE -ALARM AND 78mAMAXIMUM IN ALARM. NOMINAL STANDBY CURRENT IS OmA. ALARM CURRENT IS 7mA MAXIMUM WHEN TEST MAGNET IS REMOVED. A05 -201 -02 Page 2 --------------- , ic.'.I= BL! ',_P 1111 ITS L1 --I I L�ro Eao I I L1A` I AF;.Ht.l :.I1nIL:+.P,v i:OIJiACiS �i1 FAIJ sHU i0O1NIJ ATC I I I I ALARM All :elllAR' / CONTACTS SHO \NN IN ANDBV CONTACTSTRANSFERDURINC; AL:+RI,I AS INDICATED BV THE ARROWS I I 1RnusLE roNTncis I To I I I -------- - - - - -1 I!L Lr =;iE[• FIRF %1L A,tl.1 FIR11 DE TEr1•iP 1:I IHE LOOP` -------- - - - - -- I I I I L >h-J L 121 L:22 ° oa'FA. S-IDO ll ETC S I Is I I I ALARAI AUXIIIARV CONTACTS SHOt`:IJ n< STANDBY CONTACTS TRANSFER DURING ALARM AS INDICATED BY THE ARR_S I I I TROUBLE CONTACTS I I L-------- - - - - -I LAST DETECTOR IN 1 HE L—P 1:• -1I1IIEL'T PO:NER 101111 :E TO APPROPBIA T E TERf.III IAL:. OF EACH DETEI TOR SEE SPE -FICAT1.11 Fi.B _CO''0NAL I`�l': :Eft SUI`VLI INFUR1 "NOIu 'OR 'O JIBING OF AUXILIARY 0EVICES REFER TO ANUF.GTURERS _ ST ALLATIONINSTELICTIONS OR CONTACT AANUFACTURFP. CAUTION: Do not loop wire under terminals. Break wire run to provide supervision of connections. Wiring Diagram for DH400ACDC 4 -Wire Duct Detector System Equipped Without a Control Panel P LARI.ISIGNAL �—�y AUX VD :IJER { -r• F I I ,v I - -il DUCIDEIECIDR IiA400Z (OPTIONAL( 11- 11A(CDG FEn*OTE NN ALARMSIGNALl11 �-- -�I L IWER-i E ' t i- r --���' RESET I -I �' IEsi DUCT DET ECTOR R15N51 DH4MAC.DC (OPTIONAL, REMOTE TEST s1Fi1JN LJd.I.I SICNAt rr I��y DUCT DE IECT OR .AaOn (ORTIONAIr OH-IL IACUC AUDIBLE ALE21 I I I I I I I I I I I I I _ I EOL RESISTOR SPECIFIED B'• PANEL IeAINUFAr7THEe System Wiring Diagram for DH400ACDC 4 -Wire Duct Smoke Detectors Using a UL Listed Control Panel c - SEE SPECIFIi;,:T IO::S G;IR - -- ---- .- - - - - -- IIiPUT <_ ±,_ 1111 i ADDITIONAL POWER I SUPPLY INFORMATION L<,,'J L' <0J I 2 ll, I I .'.IA. :D1.Ir TC, SII TO• ) <.ItiTD`rxlN ETc )F 11IR 1 116 1' '. I ICE 1 1 � � MANUFACTURERS IIJ 74LLATIOJ IN TRU'T �''� I .O.IT. :�T ;Tr•. t I O ,"-T I I A LA R,I U A III.IAl% (iN T,1':; TS SHOWN I:N I I s1AN7BV TAI T- HIT OARING ALANNI AS INDLL,.ATEO B'i THE ARROW S I .: rchl I'll NI.T 1- 'IuTACTS I I I � I r. EI�r I I I &2 1 ALARM I `� i•r ALARI.1 SIGNAL I I COMMON- _ \ 11_r AUX POWER I I Ly A78- 2753 -00 I I FIELD I I•I AUX POWER INSTALLED I I I I JUMPER ID I I i I TROUBLE J I POLNER I 11 CONTACTS ---- - - - - -I APA451 AUDIBLE PIEZO ALERT WITH ALARM AND POWER (TROUBLE) LE DS. FOR STAND ALONE APPLICATIONS ONLY. APA451 RECOMMENDED FOR COMPLIANCE TO NFPA 90A. LOCATE IN NORMALLY OCCUPIED AREA OF PREMISES I I - ALARM( +)_ _ _5G� SIGNAL I AUX POWER ( -) 6 1 2 1 I �I �I 4 RESET ( -) 3'u1 �r 3 RESET I I I TEST ( -) 4 5 TEST 1 I I I I I SUPERVISORY I11 CONTACTS 10 1 AUX POWER ( +) 7 6 1 51-400ACDC I RTS451KEY Duct Smoke Detector Remote Test Station D. TOACDC DUCT DETECTOR Wiring Diagrams for Optional Accessories Pdgc j A05- 201 -02 Ordering Information Part No. Description PUS451KE1' Remote test station xvith key (see below) DIt400ACDCI 4 -wire ionization duct detector NIOD40OR Sensitivity test module DI1400ACDCA _Same as above, Canadian model PA400 Piezo sounder DI1400ACDCP 4 -wire photoelectronic duct detector RA400Z Remote annunciator alarm LED 1451DII Replacement ionization sensor head CRT400 Ion cover removal tool 2451 Replacement photoelecuonic sensor head F36 -05 -00 Replacement air filters (two per package) Accessories \102 -04 -00 Test magnet ST-1.5 Metal sampling tube duct widths 1' --" P45 -21 -00 End cap for metal sampling tubes ST -3 Metal sampling tube duct widths 2' -4' RS 14 lon replacement screen S 5 Metal sampling tube duct widths 4' -8' RS24 Photo replacement screen ST -10 Metal sampling tube duct widths 8' -12' R59 -18-00 Calibrated test card (for photo units only) APA451 Annunciator with piezo alarm and power LEDs A2650 -01 Replacement installation hit (mounting (see below) hardware) RTS451 Remote test station :. rDl Yv rat � t A-1 Pi14S] :11u.uncult6r With RTS4SI Rcillotc 7cst Station y Piezn Mann and 1'ouuer LELIs System Sensor Worldwide Distribution In Canada: In the United Kingdom: In India: hr the Far East S)'stea Sensor System Sensor Canada System Sensor Europe, Ltd. System Sensor India Piu a a Far East, Ltd. 6581 Kitimat Road, Unit ti7 Horsham Gates III, North St. A -204 Maheshwari Nagar Suite 706, New T\ I" Centre - Mississauga, Ontario Horsham, blest Susses Orka Mills Lane )' 7 Canton Road Canada L5N 3T5 RI-113 5PI, United Kingdom Andheri East, Mumbai 400093 "I'sifishatsui, Kowloon, )long Kong Telephone: 90S-832-0767 Telephone: 44- 14032'6500 Trlefas:91 -022- S2U2564 I "elephone: 552 -2730 -9090 Fax: 905-812-0771 Fax: 44-1403-276501 Fax: 852.2736-6550 AUS -201 -02 Page 4 GENERAL The Air Products & Controls MR Series Fntacts which Control a Relays offer SPDT or DPDT 10 -amp contacts which may be — -S3403 operated- by- one-of four +nput control- voltages - - -A-s ere ay _ t ^ ^R 1014 or CR, may be energized from a voltage source roate� punt terminals. MR 1041C or CR. 115 VAC, or 230 VAC by wiring to apP P Each relay contains a red light- emitting diode (LED) which ind MR -20vC or CR. Cates the relay coil is energized. Relays may be 'snapped apart" MR -2041C or CR) from a standard four - module assembly and used independently These devices are ideal for applications where local contacts are required for system status, remote contacts.Theare suit- electrical electrical loads and general purpose switching- Y able for use with HVAC, Temperature Control, Fire Alarm, Se- CS1181 curity, Energy Management, and Lighting Control Systems. CST33 The Air Products & Controls MR -199 Heavy Duty Power Re (MR -104 and DPDT MR -204 lays are designed for control applications where 30-amp contacts are required. The 24 VDC and 120 VAC relays are Series ONLI� mounted in a rugged steel enclosure. MR SERIES FEATURES (Excluding MR -199 Series) • Each relay position may be energized from one of four input control voltages. Each relay position contains a red LED which illuminates when the coil is energized. This provides a timesaving convenience when checking an installed system, no metering is required. • Single, dual, or triple relay modules may be 'snapped apart" from a standard four - position master. • SPDT or DPDT relays available. Available in dust -proof metal enclosures (with gray plastic cover on MR -101 /C and MR- 201 1C) with LED viewing port Red enclosure available on some models. Track mounting hardware to facilitate installation in standard - - -- 1 -300 January 6, 1999 M EA 73 -92-E 73 -92 -E, Vol. 111 (MR -101/C or CR, (MR -2011C or CR, MR-1 041C or CR) MR -204 /C or CR) cabinets. UL recognized relays rated at 10,000,000 mechanical opera tions.. fir The MR-1011C J 3 alli - s - - The MR -1041C li _��DO'25 VJr "�' _. 711_�011` O hn USCO 10' •nSia� 2 O ac,7. -- ! . - . Secul i',y Sl-[ �" 1I'C - np. <�765. rag r t State Fire State Marshal i 7300- .1004:101 ` - (MR- 101 /C, MR- 104 /C, MR-201 IC, MR- 204 1C) cabinets. UL recognized relays rated at 10,000,000 mechanical opera tions.. fir The MR-1011C J 3 alli - s - - The MR -1041C li _��DO'25 VJr "�' _. 711_�011` O hn USCO 10' •nSia� 2 O ac,7. -- ! . - . Secul i',y Sl-[ �" 1I'C - np. <�765. rag PRODUCT LINE INFORMATION 05�l�iCT ,SVECIFICAT[ONS FOR tL 'IVCyLTk�GE CONTROL RELAYS Model Description Single SPDT Relay with LED and track- mount- MR -101/T ing hardware (t1L recognized). ,er requirements: R -101 Position is rated at 0.015 amps (15 miltiamps) @ 24 MR-1011C Single SPDT Relay with LED, mounted in metal k(', 24 VDC, 115 VAC, 230 VAC. backbox with plastic cover (UL listed). R Position is rated at 0.035 amps ( 35 miltiamps) @ 24 MR- 1011CR Single SPDT Relay with LED, mounted in metal -291 4C, 24 VDC, 115 VAC, 230 VAC. backbox with red plastic cover (UL listed). ays: All relays are UL recognized components. NOTE: MR -1041T Four - Position SPDT Relay vAth LEDs and track - models with enclosures ( "C" suffix) are UL listed assem- mounting hardware (UL recognized). y s (-excludes MR- 199X -13C and MR- 199X -14C)- MR -104 /C Four- Position SPDT Relay with LEDs, mounted :losure: 18 gauge CRS, plated with 112" conduit knockouts include a metal in metal enclosure (UL listed). - _ . and bottom). The MR -101 /C and MR -2011C cover. MR 1041CR SPDT n °aim red cover (UL listed). :kt�ox with durable plastic taltbackbox with ntact rating: 10.0 A @ 115 VAC resistive. °F). MR -201sT Single DPDT Relay with LED and track- mount- ibient temperature: -50 °C to +85 °C ( -50 °F to +185 ing hardware (UL recognized). nensions: mm) H x 2.125' (54 MR -2011C Single DPDT Relay with LED, rnounteo in metai b cover (UL listed). ackbox with ptasbc NR -1011T and MR -2011T are 3.0" (82 'nm) W x 1.5" (38.1 mm) D. MR- 201 /CR Single DPDT Relay with LED, mounted in metal MR and MR- 204/Tare 3.0" (82 mm) H x 8.5" (215 mm) backbox with red plastic cover (UL listed). -1041T JY x 1.5" (38.1 mm) D. 6.125" (130.2 mm) H x 3.25" MR -204(T Four - Position DPDT Relay with LEDs and track - mounting hardware (UL recognized). MR -1011C and MR -2011C are DPDT Relay with LEDs, mounted (82 mm) W x 2.5" (63.5 mm) D. 6.125" (1302 mm) H x 9.5" MR -204/C Four - Position in a metal enclosure (UL listed)_ MR -104 1C and MR -2041C are DPDT Relay with LEDs, mounted (241.3 mm) W x 2.5- (63.5 mm) D. MR- 204iCR Four- Position a red cover (UL listed). in metal backbox with RODUCT SPECIFICATIONS -duty DPDT Relay only, 24 VDC coil input OR HEAVY -DUTY POWER RELAYS MR- 199X -13 Heavy (UL recognized). antact arrangement: DPDT standard. 2 MR- 199X -13C Heavy -duty DPDT Relay, 24 VDC dCoil input, recognized). ontact rating: 30 Amps @ 240 VAC; 20 Amps @ 277 VAC; mounted in enclosure (UL 120 VAC coil in- IP @ 250 VAC. MR- 199X -14 Heavy -duty DPDT Relay only, :bil power: MR- 199X43 is rated at 24 VDC @ 85 mA. pui (UL recognized)- 120 VAC coil input, 4R-199X-14 is rated at 120 VAC @ 85 MA °17). MR- 199X -14-C Heavy -duty DPDT Relay. (UL recognized). - emperature range: -30 °C to +50 °C ( -22 °F to +122 mounted in enclosure :or MR- 199X -13: -55 °C to +80 °C (-67 °F to +176`F). :or MR- 199X -14: -55 °C to +45 °C ( -67 °F to +113 °F). MR- 199X -13 and MR- 199X -14 is 313 - (79.4 mm) dimensions: ,igh x 2.5" (63 5 mm) wide x 2.31- (58.7 mm) deep. mm) high x MR- 199X -13C and MR- 199X -14C is 5.31" (134.9 3.38" (85.9 mm) wide x 3.13' (96.8 mm) deep. ..-.- n �. wvc MP. 5EK«S nor,.`.. MOUNTING LISTINGS RED COIL VOLTAGE CONTACTS UL, COVER MODEL 24 24 120 230 SPD T DP DT DPDT Track (Add Spacer Enclosure CSFM, ULC suffix.) MEA NUMBER VDC VAC VAC VAC (10A) (10A) (30A) MR -101!7 X X X X 1 X X X MR -101lC X X X X 1 X X " MR -104/T X X X X 4 X X X X MR -104 /C X X X X 4 X MR-201 [T X X X X 1 X X X _ X X X 1 MR-201 IC X X X - t\•1R -204 (T X X X X 4 X X X — t.��, -20a/C X X X X ~ X � MR- 199X -13 X 1 1 X. x -- - - pp.ce ? of