Loading...
PL-3-13-427_Plans z o 4 ELEV. +9.90 _ - EXISTING � � zQ EXISTING FAMILY ROOM EXISTING FAMILY ROOM " o o y a� a 4 TO REMAIN TO REMAIN EXISTING 24 DOOR w 0 ' � oNEW 32" MTL DOOR EXISTING LAV. © TO BE REMOVED x x a © x � � o • WITH W.P. TRESHOLD TO REMAIN " " GENERAL NOTES EXISTING RELOCATED / EXISTING 32 DOOR - U a x � o " 18 18 " TO BE RELOCATED PANEL A I z ?. U> . 1. THE CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND EXAMINE THE EXISTING 32 DOOR ELECT PNL. "A"- 1 II TO REMAIN z r > w x TO REMAIN -•� ,�- II wca � x � o ~ . �- F- o EXISTING TOILET / I i TOIS REMAIN OIL� w o o p Q P PLANS AND IT WILL BE ASSUMED THAT THE CONTRACTOR HAS _ a -._.__. a o .-.-.-_.-.-.-. - -•-•-•-•-•-•-•-•-•-•-� -• -•-•- -•- •-.-•-•-• INVESTIGATED AND IS FULLY INFORMED AS TO THE CONDITIONS AND -•- - - - -• ``•- -1 �- -• ° - •- - _vv, _�' TO REMAIN _.- _.-.-.-.-•- T" -: -. -�'- -� o ¢ o x x Q �, o ENCOUNTERED AS TO CHARACTER QUALITY AND r ' i r' -- ' �'- -t r x r n q LJ ° H3orv� w �� MATERIALS TO BEE CD I I V EXISTING FIXED GLASS I I I I �' ! I EXISTING FIXED GLASS ��-, o� Q o m QUANTITIES OF WORK TO BE PERFORMED AND MATERIALS TO BE OUTLINE OF EXISTING I TO REMAIN I OUTLINE OF EXISTING �, N v v I TO REMAIN =� . axoa - off °� � FURNISHED AND AS TO THE REQUIREMENTS OF THE PLANS. I -� Z NEW CABANA I STAIRS TO REMAIN I EXISTING LAV.-tt� .- v F a a o y v 3 N AND I I STAIRS TO REMAIN I I -�r BATHROOM I I TO REMAIN EXISTING BATHROOM I ¢ Q o N 3 2. THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS . I I N�1N POWDER -�F CURTAIN ROD I I I I I TO REMAIN CONDITIONS AND BE RESPONSIBLE FOR SAME. DISCREPANCIES BETWEEN I I N I-I- EXISTING LIGHT FIELD AND DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE - - - - - - J ROOM NEW PEDESTAL d - - • - _ _ - _ _ _ - �� J- -/ TO REMAIN ARCHITECT. - �V' - CUh�B -�� I EXISTING SHOWER I EXISTING PARTITION �- - - I H ' EXISTING WATER HEATER rTO REMAIN I I EXISTING WATER HEATER I / I EXISTING SHOWER 3. DO NOT SCALE DRAWINGS. I I/ } TO REMAIN -� 6" 1 o / TO BE REMOVED I . w 5 -2 5 4 0 -x3.-6 I / TO REMAIN -rr- I X TO REMAIN 4„ EXISTING LIGHT - I • / I 0 0 0 0 4. CONTRACTOR WILL GUARANTEE IN WRITING ALL MATERIALS AND •� -� NEW TOILET ci N, r- -� TO BE RELOCATED IG U U U U WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL I I -`� .'_.'� I " I I' ' EXISTING SINK EXISTING CLG. MOUNTED L-•'_•'_•'� ( z EXISTING SINK -� --� � EXISTING 36 DOOR II EXISTING 36 DOOR ACCEPTANCE BY THE OWNER AND WILL, AT HIS OWN COST, REPAIR OR TO REMAIN z I TO REMAIN I I� TO REMAIN FLUOR. LGT TO REMAIN I TO REMAIN - w w w w REPLACE ALL WORK OR DAMAGES CAUSED BY WORK WHICH BECOMES i i� 5'-4" 9'-6" II DEFECTIVE DURING THE TERM OF THE GUARANTEE. _ _ __ _ I I� - EXISTING CLG. MOUNTED - - EXISTING GARAGE FLUOR. LGT TO BE REMOVED r 4' 4� � I I EXISTING WASHER 5. CONTRACTOR SHALL COORDINATE AND SUPERVISE HIS WORK AND WORK I I� j EXISTING WASHER MTL DOOR � � • •I BY SUBCONTRACTORS. I IL - J TO REMAIN TO REMAIN i}� / I IL - J TO REMAIN / / 6, ALL WORK IS TO BE DONE IN STRICT COMPLIANCE WITH THE FLORIDA �� - EXISTING STL. COLUMN Q F I Ir BLDG. CODE 2007 EDITION, N.E.C. 2008 EDITION, N.F.P.A. 72 2002. EXISTING DRYER EXISTING DRYER _ EXISTING STL. COLUMN M M M M r, .� .. TO REMAIN I I TO REMAIN TO REMAIN EXIT TO EXTERIOR Q N cry ° cI FFPC 2007 AND ANY OTHER LOCAL GOVERNING AUTHORITIES. I I� I TO REMAIN I I I I• I I 0 N N III � - - - - - - - - -, . .L , _ , J - - - - _ _ _ _ _ • � , 7. ALL MATERIALS AND WORK TO CONFORM TO LATEST GOVERNING BUILDING I o NEW CHANGING AREA I I �° I I N "' CODES AND REGULATIONS. � r.-.-.L� _,_,_,� � ,. . I EXISTING GARAGE I EXISTING GARAGE � ° � N S. ALL COUNTERS AND CABINETS ARE BY OTHERS -•-•--� 4Q I I I EXISTING FIXED GLASS -' --� TO REMAIN TO BE CONVERTED I I I EXISTING FIXED GLASS ELEV. +9.90 I I I TO REMAIN I I I I I TO REMAIN 9• ALL FINISHES ARE TO BE COORDINATED WITH THE OWNER. COORDINATE ALL DOOR TYPES AND DOOR HARDWARE WITH OWNER I I ' 10, ALL DRAWINGS UNDER THIS SET OF PLANS ARE TO BE SUBMITTED TO ALL I o THE PROPER AUTHORITIES AND BUILDING DEPTS. FOR REVIEW AND _ 0 PROCESSING. NO WORK IS TO BE STARTED UNTILL ALL PROPER PERMITS -_ -_ _ _ _ _ • N I I I _ - _ - - _ - J -• - - - - - - - - - I I O _ _ _ I I �. _ _ - - - - - _ _ ARE ISSUED. I L.-.-.-.�- EXISTING GARAGE DOOR •-• EXISTING GARAGE DOOR •-� � EXISTING GARAGE DOOR •-. EXISTING GARAGE DOOR •-� _ _ _ _ TO REMAIN REMOVE ALL TRACKS AND -__ __.J t.._.-.-.-.-.J TO REMAIN REMOVE ALL TRACKS AND - _._._.J 11. WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER J SECURED PERMANENTLY CLOSED SECURED PERMANENTLY CLOSED z W �j N F.B.C. 2007 EDITION. TO BE 20 GA. AT 16 O.C. O M 12. GYPSUM BOARD IN BATHROOMS SHALL BE WATER RESISTANT CEMENT BACKING BOARD AS PER F.B.C. PROVIDE NON SKIT CER NOTE: Q W > W ce TILES AT BATHROOM FLOORS. PROVIDE CER TILES AT ALL BATHTUBS AND NEW FLOOR P LAN ® DEMOLITION PLAN " 1. PROVIDE R-19 INSULATION AT ALL PARTITIONS � � SHOWER WALLS FOR A HEIGHT OF 72 INCHES. AS PER F.B.C. Q � ° W COORDINATE STYLE AND COLOR WITH THE OWNER. BETWEEN THE GARAGE AND NEW ADDITION. OU) (GREEN BOARD SHALL NOT BE USED) SCALE: 1/4"=1'-O" SCOPE OF WORK CONSISTS OF THE FOLLOWING: SCALE: 1/4"=1'-O" z W . Li- W 2. REMOVE EXISTING GARAGE DOOR TRACKS �/ AT THE GARAGE DOOR ADJACENT TO THE ALL DIMENSIONS ARE TO BE FIELD VERIFIED ALL DIMENSIONS ARE TO BE FIELD VERIFIED W Ll.. - Z ADDITION AND PROVIDE A PAD LOCK. - - - = EXISTING ITEMS TO REMAIN 1 . RENOVATE EXISTING PARTIAL GARAGE TO ADD A -- - - - EXISTING ITEMS TO REMAIN �/ W z THE GARAGE TRACK IS TO BE UNBOLTED AND REMOVED - - - _ _ _ _ _ Y � Q AFTER THE TRACK CURB. PAD LOCK DOOR TO BE NEW ITEMS AND PARTITIONS NEW CHANGING AREA WITH EXTERIOR ACCESS, - - - - - - EXISTING ITEMS TO BE REMOVED �y U) � Q --� PERMANANTLY CLOSED AND WATER PROOFED NEW CABANA BATHROOM AND THE REMODELING NOTE: O z � CONSTRUCTION MEANS AND METHODS ALL NOT USED WATER OR SANITARY LINES _ 3. PROVIDE 2 FT HIGH OF THORO-SEAL WATER PROOFING ® OF THE EXISTING POWDER ROOM. AS INDICATED. 1. THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE OR OR APPROVED EQUAL, THRU-OUT FULL PERIMETER ALL WORK IS TO BE DONE IN STRICT COMPLIANCE ARE TO BE HARD CAPPED. PROCEDURES, SAFETY PRECAUTIONS, SHORES, RESHORES, LATERAL BRACING AT THE NEW PARTITION ON THE GARAGE SIDE, WITH THE FLORIDA BLDG. CODE 2010 EXISTING AND PROGRAMS IN CONNECTION WITH THE PROJECT, ARE THE SOLE RESPONSIBILITY OF THE w Q ~ CONTRACTOR. OUR SERVICES DO NOT GUARANTEE NOR ALSO PROVIDE CONT. W.P. CALKING THRU-OUT AT SLAB. ASSURE LIABILITY FOR THE JOB SAFETY, TEMPORARY SHORING AND BRACING GROUP R3 NOTE: THERE ARE NO NEW A/C UNDER THIS CONTRACT IQ-- AND THE PERFORMANCE OF THE CONTRACTOR. TYPE VB Z 2. THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE SAFETY ALTERATION LEVEL-2 4 Z O REQUIREMENTS OF LOCAL BUILDING CODE AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL LAWS. NOTE: NO AIR CONDITIONING UNDER THIS PERMIT GENERAL DEMOLITION NOTES 3. PROVIDE ALL SHORING, BRACING AND SHEETING AS REQUIRED FOR SAFETY, STRUCTURAL STABILITY AND FOR THE PROPER EXECUTION OF THE WORK. REMOVE WHEN WORK IS COMPLETED. 1. THE CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR HAULING 4. PROVIDE AND MAINTAIN GUARD LIGHTS AT ALL BARRICADES, RAILINGS, AND LEGALLY DISPOSING OF MATERIALS REMOVED IN DEMOLITION WORK. ABSTRACTIONS IN THE STREETS, ROADS OR SIDEWALKS AND ALL TRENCHES OR PITS ADJACENT TO PUBLIC WALKS OR ROADS. 2. THE CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND EXAMINE 5. AT ALL TIMES, PROVIDE PROTECTION AGAINST WEATHER (RAIN, WIND, THE PLANS AND IT WILL BE ASSUMED THAT THE CONTRACTOR HAS STORMS OR THE SUN), SO AS TO MAINTAIN ALL WORK, MATERIALS, APPARATUS INVESTIGATED AND IS FULLY INFORMED OF THE CONDITIONS AND AND FIXTURES FREE FROM INJURY OR DAMAGE. PROVIDE ADEQUATE BRACING TO THE MATERIALS TO BE ENCOUNTERED AS TO CHARACTER, QUALITY AND ELEMENTS ALREADY IN PLACE (ESPECIALLY MASONRY WALLS) AGAINST WIND FORCES QUANTITIES OF WORK TO BE PERFORMED AND MATERIALS TO BE O CAPABLE OF DAMAGING THIS WORK. FURNISHED AND AS TO THE REQUIREMENTS OF THE PLANS. M 6. AT THE END OF THE DAYS WORK, COVER ALL WORK LIKELY TO BE DAMAGED. ANY M WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION SHALL BE REMOVED AND REPLACED 3. THE CONTRACTOR SHALL REMOVE ALL SPECIFIC ITEMS INDICATED ON THESE DRAWINGS AND ALSO REMOVE ANY OTHER ITEMS OR CONSTRUCTION � o WITH NEW WORK AT THE CONTRACTOR'S EXPENSE. AS REQUIRED TO ACCOMPLISH ALL NEW WORK TO AREAS SHOWN 7. THE CONTRACTOR SHALL PAY FOR ALL DAMAGES TO ADJACENT � STRUCTURES, SIDEWALKS AND TO STREETS OR OTHER PUBLIC PROPERTY OR 4, ALL DIMENSIONS SHOWN ARE TO BE VERIFIED IN THE FIELD AND ANY Q PUBLIC UTILITIES. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE O ARCHITECT BEFORE PROCEEDING WITH THE WORK. 8 "OSHA" SAFETY INSPECTIONS ARE NOT A PART OF OUR SERVICES. OUR PRESENCE C)z) ON SITE FOR OBSERVATIONS INSPECTIONS OF THE WORK IN PROGRESS OR WEETINGS) 5. BUILDING CONTRACTOR TO CUT OUT AND REMOVE EXISTING Q SHALL NOT CONSTRUED AS OUR ACTING AS "OSHA" INSPECTORS. CONFORMING WITH ALL WALLS END SLAB AS INDICATED, O APPLICABLE 'OSHA" SAFETY REGULATIONS ARE THE SOLE RESPONSIBILITY OF THE NOTE: 6. THE AMOUNT OF DUST RESULTING FROM DEMOLITION SHALL BE • H d CONTRACTOR. 1. ALL WALL HUNG FIXTURES TO BE CONTROLLED TO PREVENT THE SPREAD OF DUST TO AVOID CREATION OF CAPABLE OF WITHSTANDING 250 LBS A NUISANCE IN THE SURROUNDING AREA. USE OF WATER WILL NOT BE C� a POINT LOAD. PERMITTED WHEN IT WILL RESULT IN, OR CREATE, HAZARDOUS OR OBJECTIONABLE CONDITIONS SUCH AS FLOODING AND POLLUTION. 2. USE MINERAL WOOL BATTS AT 1-HOUR WALL. 7. ALL EXISTING SURFACES SUCH AS WALLS FLOORS CEILINGS BASES ETC. v� v' BOTT OF EXISTING TRUSSES F-i S z THAT ARE AFFECTED BY THESE ALTERATIONS ARE TO HAVE NEW MATERIAL o AND FINISH AS REQUIRED TO MATCH ALL ADJACENT EXISTING FINISHES i-i N 00 ­4 WALL HUNG FIXTURE NOTE: M q EXISTING GYP. BIRD CEILING ALL WALL HUNG FIXTURES TO BE SUPPORTED AS 8. GENERAL CONTRACTOR SHALL DO ALL CUTTING AND PATCHING OF TO REMAIN EXISTING CONCRETE SLABS PARTITIONS ETC...AS MAY BE REQUIRED PER F.B.C. LATEST EDITION NEW 3000 PSI CONC. (V A I STEEL STUDS SHALL BE DOUBLED OR NOT LESS FOR ALL TRADES TO ACCOMPLISH ALL WORK REQUIRED BY THESE cn THAN 20 GA W A MIN. EFFECTIVE MOMENT ES ENERTIA EXISTING CONC. SLAB W/ 6X6 W1.4XW1.4 W.W.M. CONTRACT DOCUMENTS. CONTRACTOR SHALL DO ALL PATCHING AND �") GALV. MET. RUNNER / ON 6 MILL W.P MEMBRANE PROVIDE NEW FINISHES TO MATCH EXISTING SO AS TO MAKE THE It ` SCREWED TO WD TRUSS EQUAL TO 0.864 IN. 4. STUDS TO BE RIGIDLY AND MESH TO REMAIN AT NEW SLAB OPENINGS "PATCHED AREA" INDISCERNIBLE FROM THE EXIST. ADJACENT AREA. ri�j rn 0 BOTT CHORD W/ TEC CONNECTED TOP AND BOTTOM TO PREVENT -.-._. -. _.-. SCREWS AT 24" O.C. SIGNIFICANT END ROTATION OR DISPLACEMENT. A 9. UTILITY SERVICES: MAINTAIN EXISTING UTILITIES INDICATED .e z HORIZONTAL MEMBER SECURELY FASTENED TO NOT LESS THAN -X-X-1 -X X-X-X-I-- X-X- OREMAIN, KEEP IN SERVICE, AND U.O.N.PROTECT AGAINST DAMAGE R, o TWO STUDS SHALL BE INSTALLED FOR THE ATTACHMENT OF EACH o HUNG PLUMBING FIXTURE. 10. PRIOR TO DEMOLITION, VERIFY THE SCOPE OF WORK W/THE q TENANT AND DISPOSITION OF ANY REMOVED ITEMS. SLAB CUT RE M I D IAL DETAIL- 1/2' GYP. BD. ON 25 GA. 11, REMOVE ALL SPECIFIC ITEMS INDICATED ON THESE DRAWINGS AND H y. X 3.5/8 METAL STUDS 3-5/8" OR 5-5/8 X 16 GA. N.T.S. ALSO REMOVE ANY OTHER ITEMS OR CONSTRUCTION AS REQ D. TO l� w W I STEEL STUD ® 16" O•C. ACCOMPLISH ALL NEW WORK TO AREAS SHOWN. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES OR 12. PATCH CONC. SLAB TO MATCH EXISTING STRUCTURE, AFTER NEW GALV. METAL RUNNER PLUMBING FIXTURES HAS BEEN LOCATED. OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE w W/ 3/4" LONG POWER AS A PREVENTIVE TREATMENT TO NEW CONSTRUCTION. TO BE DONE PRIOR 13. ALL REMOVED ITEMS IF ANY SHALL BECOME THE PROPERTY OF CHECKED ACTUATED ASTNERS ST X 1 T GA. RACK BACKING TO ANY CONSTRUCTION. THE CONTRACTOR WITH THE APPROVAL OF THE OWNER AND AT 2 " O.C. STEEL STUD TRACK BACKING A PERMANENT SIGN, WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER DRAWN I I AND NEED FOR RE-INSPECTION AND TRATMENT CONTRACT RENUAL, SHALL SHALL BE REMOVED FROM THE SITE. o CONT. BASE AS PER OWNERS SPECS BE PROVIDED, THE SIGN SHALL BE POSTED NEAR THIE WATER HEATER OR 14. CONTRACTOR TO SHORE UP EXISTING ROOF TO REMAIN, PRIOR TO DATE 11-26-2012 u ELECTRICAL PANEL. REMOVING ANY BEARING WALLS OR PARTITIONS. COMM,NO. 12-201 EXISTING CONC SLAB o TYP. INTERIOR PTN . SCALE 1 "=l '-C)" 3 f e� l z z 4 ADD SMOKE/CARBON MONOXIDE DETECTORS. " a C Q ANY AND ALL CLOTH AND RUBBER wo � ° aa � A - EXISTING FAMILY ROOM BATHROOM RECEPTACLE ON 20 AMP CKT INSULATED CONDUCTORS TO BE REPLACED. - EXISTING FAMILY ROOM x � � TO REMAIN AND G.FI PROTECTED TO REMAIN w 0 u x H EXISTING 110V ELECT. OUTLETS TO REMAIN �`� °- 5 5 Q ° z o EXISTING LAV. z VERIFY TO BE GFI. �a � 4ao ¢ Q EXISTING RELOCATED / EXISTING RELOCATED 3 o w w w p x o . / TO REMAIN II EXISTING 32" DOOR ELECT PNL• A - D I I z a o o o Q N S? 'a EXISTING 32" DOOR ELECT PNL. "A'"- I TO REMAIN _ NEW EXHAUST FAN o �- , _ EXISTING TOILET / � a TO REMAIN _ a I TO REMAIN _._._._ °oo _._.�1_._._._._. SEE DETAIL THIS SHEET Z¢ ogw� '� � w� ° z CONNECT TO THE EXISTING " EXISTING FIXED GLASS 3 u. A-- EXISTING FIXED GLASS a H r 3 I I �/' v ) I I OUTLINE OF EXISTING I I n I v v A-�` I ! TO REMAIN _j a. Z ° � � � 3 3 ROOF VENT AT THE PREVIOUS CONNECT NEW 3 LINE TO THE I I OUTLINE OF EXISTING , � O I TO REMAIN TOILET ROOM LOCATION 3" LINE AT THE EXISTING TOILET. STAIRS TO REMAIN I I I z � CABANA `� I I STAIRS TO REMAIN I EXISTING LIGHT I Z NEW CABANA PLUMBER TO FIELD VERIFY SLOPE DIRECTION I I �� i� BATHROOM I " . . TO REMAIN�j jA� ! BATHROOM A-21 CONNECT NEW 3 LINE TO THE _�- EXISTING LIGHT vs 2" �'2 I I - J I ! v NItW POWDER LAV. PEDESTAL ' �� 3" LINE AT THE EXISTING TOILET. J N�1N OMWDER JA - - - - - - J ROOM 3 I j - - j TO REMAIN LAV I r % ` " _ _ PLUMBER TO FIELD VERIFY SLOPE DIRECTION Lu r (1 F.U.) ' ' EXISTING WATER HEATER 2 I AIN RO / EXISTING W.H. „ I I ° I • I ! EXISTING SHOWER I I TO REMAIN z g I O O A.A.V. rl 3 . . TO REMAIN 3 0 x / C) ( ! x I ! p IU- FU- - I ! / �' I PTO REMAIN . . NEW TOILET LG.- - I II LG._._.' I w w " EXISTING SINK -• j Q O EXISTING SINK - EXISTING 36 DOOR I TO REMAIN " � I NEW EXHAUST FAN C.O. I I TO REMAIN I TO REMAIN I I ca Lj z SEE DETAIL THIS SHEET _ j a C.O. W.C. III - J I - - I Ir - . X o I EXISTING RELOCATED �^L� m m „ ( ) EXISTING GARAGE I / I I EXISTING WASHER w LIGHT CONNECT TO - pt. I / 3 F.U. I I' EXISTING WASHER I I ITS ORIGINAL CIRCUIT 3 3 . .I I /' TO REMAIN TO REMAIN TO REMAIN I I IL . _ J IL . _ . J NEW GFI 110V ELECT. r , A-21 N I. EXISTING DRYER OUTLETS r , � I TOISREMAINIGHT I I. EXISTING DRYER L . - J TO REMAIN - - - - - - - NEW POOL STORAGE ! I ILL - J TO REMAIN - - - - - - ° O N PLUMBING RISER I I ° ! ! I ! ; z _ _ r7i y •� N.T.S. " _- j I I - - --, EXISTING GARAGE I A-zy III SLOPE AT 1/8' PER FOOT. -? I EXISTING FIXED GLASS I TO REMAIN 1 III EXISTING FIXED GLASS NEW CHANGING AREA I TO REMAIN TOTAL 4 F.U. I I I ! I I I 3 , , Ij II I j o I I ! I I I jj CONNECT TO EXISTING I �., _,_,_,�- EXISTING GARAGE DOOR C•_.T EXISTING GARAGE DOOR •-•-•-- -� I I �-•-•-•-•-� EXISTING GARAGE DOOR L•-•T EXISTING GARAGE DOOR -� I z W M N HOT WATER LINES _ _ _ _ L,-,•_,-•_,_J TO REMAIN REMOVE ALL TRACKS AND -__ _._.J co COLD AND TO REMAIN REMOVE ALL TRACKS AND J AT THE PREVIOUS TOILET L"r'-'_' J 00 � SECURED PERMANENTLY CLOSED SECURED PERMANENTLY CLOSED _ z � ROOM LOCATION W .� W w o J /p EXISTING ELECT. PANEL "A" Q U) 1 I W F� NEW PLUMBING PLAN 120 240 1 PHASE 200 A NEW ELECTRICAL PLAN z W . U- SCALE: 1 4'"=1'-O" EXISTING 30 CRC. CIRC. BREAKER PANEL " � " W � z � Z cj� S2 1 / (CONTRACTOR TO FIELD VERIFY) SCALE: 1/4 =1 -0 1/2" 1/2" 14 LAV ALL DIMENSIONS ARE TO BE FIELD VERIFIED ALL DIMENSIONS ARE TO BE FIELD VERIFIED EXISTING ITEMS TO REMAIN CIRCUITS USE KW BRKR WIRE _ _ _ = EXISTING ITEMS TO REMAIN ol. z o V 1/2" NEW ITEMS AND PARTITIONS NEW ITEMS AND PARTITIONS O w JwC A-24 GEN PURP. 1.5 KW 15-1P 12 _ 2 A-28 GFI BATHROOM RECP 0.6 KW 20-1P 12 �•L• EXISTING 1 tOV ELECT. OUTLETS TO REMAIN Q I--- VERIFY TO BE GFI W w U WATER RISER NOTE: R NEW GFI 110V ELECT, OUTLETS z I4- N.T.S. PLUMBING NOTES: NO AIR CONDITIONING UNDER THIS PERMIT NEW 110V ELECT. OUTLETS e O 1. PROVIDE MODEL 653-B (3/4" HIP) WATER HAMMER NEW LIGHT SWITCHES ARRESTORS BY HYDRA RESTOR OR EQUAL TO BE PROVIDED WHERE QUICK CLOSING VALVES ARE UTILIZED, 2. PROVIDE SHUT-OFF VALVES AT EACH FIXTURE WATER SUPPLY NEW SURFACE MOUNTED LIGHTS CONNECTED 3. ALL SHOWER AND BATH AND SHOWER COMBINATION SHALL BE EXISTING PANEL "A" FRANKIE ELECTRIC CORP. 305-332-7516 O TO THE EXISTING GARAGE LIGHT CIRCUIT PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, 1 SUB PANEL IN KITCHEN 2 RANGE EXISTING SURFACE MOUNTED LIGHTS TO REMAIN THE THERMOSTATIC MIXING OR THE COMBINATION PRESSURE BALANCE / THERMOSTATIC TYPE. HANDLE POSITION STOPS SHALL BE ADJUSTED IN ACCORDANCE WITH MANUFACTURERS 3 SUB PANEL IN KITCHEN 4 RANGE J INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM 5 DRYER 6 AHU-1 MIXED WATER OUTLET TEMPERATURE OF 120 DEGREES FAHRENHEIT CIO 4. ALL BATHROOM FLOORS AND BASE SHALL BE OF NON SKID CER. TILES. 7 DRYER 8 AHU-1 GENERAL ELECTRICAL NOTES COORDINATE STYLE AND MNFGR WITH THE OWNER. N 9 TANK WATER HEATER 10 CU-1 M C) 4" DUCT FROM UNIT 5. EACH NEW OR REPLACED FIXTURE, SHALL HAVE SEPERATE VALVES.. M TO PROVIDE WATERTIGHT SEAL is 25 GA. THERMO FLEX 11 TANK WATER HEATER 12 CU-1 1. DO NOT SCALE ELECTRICAL DRAWINGS. 6. NEW OR REPLACED SHOWER VALVES SHALL BE PRESSURE BALANCED TO MEET ASSE d O CAULK ALL AROUND w 1016 OR CSA 8125. 2. COORDINATE ALL LIGHT SWITCHES AND TELEPHONE JACK LOCATIONS AND QUANTITIES 13 GENERAL LIGHTING 14 AHU-2 3 WITH THE OWNER. >. 7, REPLACED TOILET FLANGE TO BE RAISED TO MATCH ANY NEW FINISHED FLOOR EXHAUST FAN 15 GENERAL LIGHTING 16 AHU-2 3. MINIMUM WIRE SIZE SHALL BE X12 A.W.G., EXCLUDING CONTROL WIRING. UNLESS WITH BACK DRAFT HEIGHT. OTHERWISE NOTED ALL CONDUCTORS SHALL BE COOPER WITH THHN OR THWN 0 _ DAMPER 8. ALL FIXTURES ARE TO MEET THE MAX. FLOW RATES AS INDICATED ON TABLE 17 CONDENSER UNIT 1 18 GENERAL LIGHTING INSULATION. ALL WIRES TO BE IN MTL CONDUITS. ® N P2903.2A (RES) OR 604.4 (BLDG.) 4. OUTLET BOXES SHALL BE PRESSED STEEL OR PLASTIC, IN DRY LOCATIONS. CAST 3 19 CONDENSER UNIT 1 20 CU-2 � v ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES Q CEILING FOR OTHER CLASSIFIED AREAS. A-•I WALL CAP WITH 21 GENERAL LIGHTING 22 CU-2 0 O Nl EXHAUST AIR GRILLE 5. PROVIDE GROUNDS FOR ALL CIRCUITS. BACKDRAFT DAMPER TABLE P2903.2A MAXIMUM FLOW RATES AND CONSUMPTION FOR 23 GENERAL RECEPTACLES Z4 GENERAL LIGHTING 6" PLUMBING FIXTURES, FIXTURE AND APPLIANCES 6. AS PER N.E.C. 408.4 ALL CIRCUITS AND CIRCUIT MODIFICATIONS SHALL BE LEGIBLY 25 SPRINKLER PUMP 26 GENERAL LIGHTING IDENTIFIED AS TO PURPOSE OR USE ON THE CIRCUIT DIRECTORY LOCATED ON THE r > a O CLEAR FROM PLUMBING FIXTURE OR PLUMBING FIXTURE OR FIXTURE FITTING FACE OF THE INSIDE OF THE PANEL DOOR IN CASE OF A PANELBOARD, AND AT a C4 FIN. WALL (EXHAUSTFAN) FIXTURE FITTING MAXIMUM FLOW RATE (B) 27 POOL PUMP 28 GENERAL RECEPTACLES EACH SWITCH ON THE SWITCHBOARD. �T� �, O 0 29 POOL PUMP 30 APPLIANCES 7• IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF w po� x LAVATORY FAUCET 1.5 GPM AT 60 PSI CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS N.T.S. SHOWER HEAD (A) 1.5 GPM AT 80 PSI FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY I� �O p 00 FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. ►-4 N ,- Q WATER CLOSET 1.28 GALLONS PER FLUSHING CYCLE 8. ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS REQUIRED 1. j W M z � TOILET ROOM EXHAUST CALC. 560 VOLUME BY THE LATEST EDITION OF THE N.E.C. � A = 7.0 < 7.5 REQ. 9. ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS' LABELS WHERE 1 80 CFM (FAN) APPLICABLE. Nt FOR SI: 10. ALL WORK SHALL BE PERFORMED BY LICENSED ELECTRICAL CONTRACTOR IN A FIRST 0 EXHAUST FAN 1GALLON=3.785E •tJ W Oz -- BLOWER VENTILATOR TO BE MODEL QT80 IN'2 ELECTRICAL CONDUIT v� 1 GALLON PER MINUTE=3.785L/M 11. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE z BY NUTONE 80 CFM (94 L/S) 1 POUND PER SQUARE INCH=6.895KPA WITH THE PROCESS OF CONSTRUCTION. Q., a 7 4 25 GA. MTL. DUCT OUT THRU WALL Z8 (A) A HANDHELD SHOWER SPRAY IS A SHOWERHEAD F 12• THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES ON (B) CONSUMPTION TOLERANCES SHALL BE DETERMINED FROM REFERENCED STANDARDS DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE OF ANY CHANGES DUE TO w (C) WATER FACTOR IN GALLONS PER CYCLE PER CUBIC FOOT O FAILURE OF NOTIFYING DISCREPANCIES. Q PANEL 200A. MAIN LUG. 120/24OV. 13. ELECTRICAL CONTRACTOR TO VERIFY ALL EQUIPMENT ELECTRICAL REQUIREMENTS WITH NOTE: ALL REFERENCED FIXTURES SHALL = ,r MANUFACTURER INCLUDING CONNECTIONS, WIRE SIZES AND VOLTAGES REQUIREMENTS. BE PROVIDED ACCORDNLY TO THE _ METER COMBO PANEL 200A 1 PH. 40 SPCS. SQ D NOTIFY THE ARCHITECT WITH ANY DISCREPANCIES PRIOR TO CONSTRUCTION. SMOKE DETAECTOR STANDARDS AS PER F•B.C. 2007 1 PHASE. MAIN BREAKER � CD 14, ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL EXISTING ELECTRICAL SERVICE AND -- ALL SMOKE DETECTORS MUST BE COMBINATION SMOKE / CARBON MONOXIDE PLB 406-421 CONDITIONS, TO INCLUDE EXISTING POWER PHASE, VOLTAGE AND CAPACITY AND ALARM DETECTORS THEY MUST BE (120V) HARD WIRED, INTERCONNECTED WITH NOTIFY THE ARCHITECT IN CASE OF DISCREPANCIES PRIOR TO CONSTRUCTION. A BATTERY BACKUP AND AT LEAST 4 INCHES AWAY FROM THE NEAREST D w SIDEWALL TO THE EDGE OF THE DETECTOR. DERECTORS CAN BE NO 1-#4 THHN IN 3/4"" PVC 15. ELECTRICAL CONTRACTOR TO FIELD VERIFY THE LOCATION OF ALL EXISTING J-BOXES CHECKED CLOSER THAN 3 FEET TO THE DOOR OF ANY BATHROOM OR KITCHEN, AND AND OUTLETS AND RELOCATE AS REQUIRED ACORDING TO THE LOCATION OF NEW NO CLOSER THAN 3 FEET TO A FAN AND OR AIR CONDITIONING DUCT CONDUIT PARTITIONS. DRAWN OUTLET. IF DETRECTORS ARE NOT MOUNTED ON A SIDEWALL, THEY MUST � � GROUND CLAMP 16, ELECTRICAL CONTRACTOR TO VERIFY AND COORDINATE THAT ALL EQUIPMENT - BE LOCATED BETWEEN 4 AND 12 INCHES FROM THE CEILING TO THE TOP O EDGE OF THE DETECTORS. ALL DETECTORS SHALL BE LISTED OR LABELED ELECTRICAL REQUIREMENTS ARE TO BE PROVIDED AS PER THEIR NAME PLATE DATE 1I-26-2012 U BY A NATIONALLY RECOGNIZED TESTING LABORATORY. SPECIFICATIONS.. ��, (AS PER NFPA 72 11.8.2.2 SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE - __ 2 - 8' LONG 5/8" GROUND ROD 1 Z• PROVIDE TAMPER RESISTANT RECEPTACLES FOR ALL 15 AND 20 AMP RECEPTACLES COMM.NO. 12-201 �. INTERCONNECTED A NUMBERS THAT EXCEED THE MNFGRS RECOMENDATIONS. IN NO - CU WATER PIPE CASE SHALL MORE THAN 18 INITIATING DEVICES BE INTERCONNECTED, OF WHICH 12 �- SPACED 6 APPART u CAN BE SMOKE ALARMS, WHERE THE INTERCONNECTING MEANS IS NOT SUPERVISED) CARBON MONOXIDE DETECTORS. SHALL BE INSTALLED WITHIN 10 FEET OF ALL SLEEPING AREAS = _ - NOTE: AS PER FL. STATUTES 553.885 THE ELECTRICAL CONTRACTOR IS TO VERIFY AND PROVIDE ALL ELECTRICAL REQUIREMENTS TO INCLUDE BUT NOT LIMITED TO ALL FUSE AND WIRE SIZES AS PER EACH MACHINES AND UGHTS INDIVIDUAL NAME PLATE REQUIREMENTS , MANFGRS INSTALATION MANUAL AND SPECIFICATIONS. THE ELECTRICAL CONTRACTOR RISER DIAGRAM SHALL BE RESPONSIBLE FOR OBTAINING ALL EQUIPMENTS SPEC SHEETS AND INSTALLATION MANUALS AND 3 SHALL ALSO COORDINATE AND INSURE THAT ALL EQUIPMENT WILL BE PROVIDED IN PROPER WORKING ORDER, NOTIFY THE ARCHITECT IN CASE OF ANY DISCREPANCIES BETWEEN THE PLANS AND EACH MACHINE REQUIREMENTS G N.T.S. PRIOR TO ANY CONSTRUCTION. THE CONTRACTOR IS TO COORDINATE AND RECEIVE ALL EQUIPMENT SPECS FROM THE OWNER. V / A O <1 a F EXISTING SUPPLY DUCT TO REMAIN EXISTING RETURN DUCT EXISTING FAMILY ROOM TO REMAIN GENERAL NOTES TO REMAIN r EXISTING PACKAGED 24,000 BTUH PACKAGED UNIT p TO REMAIN n 5 1-SCOPE OF WORK. A. THE PURPOSE OF THE PRESENT PROJECT IS THE INSTALLATION OF AIR DISTRIBUTION FOR EXISTING AIR CONDITIONING ATTENDING THE PROPOSED INTERIOR RENOVATION OF THE PROPERTY. 2-GENERAL � p B. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2010 EDITION FL 4"D V O FLEX 8"D OF FLORIDA BUILDING CODE AND ALL APPLICABLE FEDERAL OUTLINE OF EXISTING REGULATIONS, STANDARDS AND AHJ REQUEST. STAIRS TO REMAIN FLEX 8"D C. REFER TO ALL DRAWINGS IN THE CONSTRUCTION SET FOR CD 6X6 EF_ METAL PIPE 4"D COORDINATION OF HVAC WORK. 50 CFM D. CONTRACTOR TO ARRAY AND PAY FOR ALL PERMITS, CD 6X METAL PIPE 6"D LICENCES, INSPECTIONS AND TESTS. EXISTING WATER HEATER 50 E. CONTRACTOR SHALL PAY ALL CERTIFICATES AND PRESENT TO REMAIN EXISTING PACKAGED UNIT 0 THEM TO OWNER. F. THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED TE - FLEX 6'D AGAINST DEFECTIVE MATERIALS AND OR IMPROPER EXISTING SINK END CAP 6"D O WORKMANSHIP FOR A MINIMUM OF ONE YEAR. TO REMAIN METAL PIPE 4"D BRAND BARD 3-SHOP DRAWINGS, P1 G. CONTRACTOR SHALL SUBMIT FOR APPROVAL WITHIN 30 DAYS WS 8X6 RG 12X6 MODEL P1124A2 V AFTER CONTRACT SIGNING, A MINIMUM OF 5 COPIES OF 75 CFM LL M O FULLY DESCRIPTIVE LITERATURE, INCLUDING BUT NOT LIMITED EXISTING WASHER EXISTING GARAGE POWER 208 1-60 W T— N - TO: AIR CONDITIONING UNITS, AIR DISTRIBUTION DEVICES, TO REMAIN TO REMAIN z M CONTROLS AND FANS. NO WORK SHALL BE PROCEEDED MAX UNIT AMPS. 12.9 AMPS WITHOUT APROVAL OF SUBMITTALS. EXISTING DRYER c( w 4-DESIGN PARAMETERS. TO REMAIN I " (,j,J (] H. OUTDOOR DESIGN TEMPERATURE (SUMMER) 91DB AND 79W6 RATED CFM 800 CFM > -- w I. OUTDOOR DESIGN TEMPERATURE (WINTER) 45DB ° NEW CHANGING AREA L K. INDOOR DESIGN TEMPERATURE (WINTER))72DBB w ` U_ (!) 5-THERMOSTATS. L. ALL THERMOSTAT SHALL BE SETTED AT 75F IN COOLING w W V) Z MODE AND 68F IN HEATING MODE. z w Z M. THERMOSTATS SHALL BE ARRANGED TO PREVENT SIMULTANEOUS OPERATION OF HEATING AND COOLING. N. THERMOSTATS SHALL START-STOP SUPPLY FANS AND ACTIVATED COOLING HEATING AND OFF MODES AS SELECTED. z C) O U) 6-DUCTWORK. 0. FABRICATION AND INSTALLATION OF DUCT SYSTEM UNDER THE EXISTING GARAGE DOOR EXISTING GARAGE DOOR G LATEST EDITION OF SMACNA HVAC DUCT CONSTRUCTION TO REMAIN REMOVE ALL TRACKS AND w Q STANDARD. SECURED PERMANENTLY CLOSED 0 P. DUCT SHALL BE FIBERGLASS 1" THICK (R-4) MINIMUM. 2 < Q. FLEXIBLE DUCTS ARE ALLOWED IN CONCEALED SPACES. z R. ALL DUCT INSULATION MATERIALS SHALL BE 1" (R-4) VENTILATION EQUIPMENT SCHEDULE -- Z o MINIMUM. U S. ALL SHOWN DUCT DIMENSION ARE CLEAR INSIDE DUCTS. 7-TEST AND BALANCE, Unit Designation EF-1 T. CONTRACTOR SHALL TEST AND BALANCE ALL VENTILATION AND AIR CONDITIONING SYSTEMS. Quantity ' y FRMIT #0 _ Location Bathrooms SH —i Area Served Bathrooms Manufacturer Broan Model No 678 >' o FAN �I.. Fan Type Bathroom Fan DriveT ,_ � _.. ._ ,. o y pe Direct _ _i.__ Airflow CFM 50 ' ELECTRIC'AL 12-41141� "I External Static Pressure inwg 0.10 Fan Speed rpm 43 MOTOR U a a Type _.. y _ _.. `Ay, W ° x w a HANGER STRAP 5'0' MAXIMUM I ALLOWABLE DISTANCE Horsepower HP ! 0 00 ° Full Load Amps 0.5 Electrical Service Available 120-1-60 `' e �! r rO' ``41,'�`E W'111 '40, `°`�'` U F -WTEAND C{.}lJNTY PULES AJCI RED END CAP DUCT COLLAR z MANUAL VOLUME DAMPER TIE WRAP C.E;IVF.D W a DUCT COLLAR MAY 0 8 203 H REGISTER CAN BY: `o q HVAC DESIGN REQUIRES YES NO CHECKED � 2 FLEX DUCT CONNECTION DETAILS GX FLE DUCT HANGING DETAILS DUCT SMOKE DETECTOR x Dom , SCALE: NTS. SCALE: NTS. x FIRE DAMPERS X DATE 11-26-2012 SMOKE DAMPERS X comm.No. 12-201 FIRE RATED ENCLOSURE X 0 FIRE RATED ROOF-FLOOR CEILING ASSEMBLE X FIRE STOPPING X DESIGNS Di 8' HVAC DUCT SMOKE CONTROL X ENERGY SOLUTIONS FBPE Cert of Authorization 29476 4445 W 16th Ave Ste 306 04-14 ' 13 Hialeah, Florida 33012 Phone: 305-219-0650 Fax:305 200 0157 Enrique Pasou I PE 70739 admin§hvac-energysolutions.com z o 4 4r D �qUpA UU � owO �� x �4 � gws, u.0p rQ � 3S � � �� �d ox Qtea' On �a, p�l Uxrw0 a � ¢ Oq�awrognU"�Va'o".F ' w gUd 104 aQQ EXISTING SUPPLY DUCT TO REMAIN EXISTING RETURN DUCT EXISTING FAMILY ROOM TO REMAIN GENERAL NOTES TO REMAIN EXISTING PACKAGED UNIT o TO REMAIN 5 1-SCOPE OF WORK. A. THE PURPOSE OF THE PRESENT PROJECT IS THE INSTALLATION OF AIR DISTRIBUTION FOR EXISTING AIR CONDITIONING ATTENDING THE PROPOSED INTERIOR RENOVATION OF THE PROPERTY. — w 2-GENERAL B. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2010 EDITION FLE 4"D O FLEX 8"D q OF FLORIDA BUILDING CODE AND ALL APPLICABLE FEDERAL STAIRS OF EXISTING REGULATIONS, STANDARDS AND AHJ REQUEST. STAIRS TO REMAIN FLEX 8"D " C. REFER TO ALL DRAWINGS IN THE CONSTRUCTION SET FOR CD 6X6 METAL PIPE 4 D p COORDINATION OF HVAC WORK. 50 CFM EF-1 z D. CONTRACTOR TO ARRAY AND PAY FOR ALL PERMITS, METAL PIPE 6"D EXISTING WATER HEATER LICENCES, INSPECTIONS AND TESTS. CD 6X 50 E. CONTRACTOR SHALL PAY ALL CERTIFICATES AND PRESENT TO REMAIN THEM TO OWNER. F. THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED E -1 V��,[FLEX 6"D AGAINST DEFECTIVE MATERIALS AND OR IMPROPER EXISTING SINK END CAP 6"D �' O WORKMANSHIP FOR A MINIMUM OF ONE YEAR. TO REMAIN METAL PIPE 4"D O 3-SHOP DRAWINGS. 0) G. CONTRACTOR SHALL SUBMIT FOR APPROVAL WITHIN 30 DAYS WS 8X6 RG 12X6 O LL M AFTER CONTRACT SIGNING, A MINIMUM OF 5 COPIES OF EXISTING GARAGE 75 CFM r- FULLY DESCRIPTIVE LITERATURE, INCLUDING BUT NOT LIMITED EXISTING WASHER W M 04 TO: AIR CONDITIONING UNITS, AIR DISTRIBUTION DEVICES, TO REMAIN TO REMAIN V CONTROLS AND FANS. NO WORK SHALL BE PROCEEDED 0 000 WITHOUT APROVAL OF SUBMITTALS. EXISTING DRYER W W 0 4 -DESIGN PARAMETERS. TO REMAIN > _ W H. OUTDOOR DESIGN TEMPERATURE (SUMMER) 91 DB AND 79WB Q ® Q E w I. OUTDOOR DESIGN TEMPERATURE (WINTER) 45DB ° NEW CHANGING AREA > 0 J. INDOOR DESIGN TEMPERATURE (SUMMER) 7808 0 W W `t i- K. INDOOR DESIGN TEMPERATURE (WINTER) 72D6 � � L� w L11 5-THERMOSTATS. L. ALL THERMOSTAT SHALL BE SETTED AT 75F IN COOLING W Z W Z MODE AND 68F IN HEATING MODE. w M. THERMOSTATS SHALL BE ARRANGED TO PREVENT ry SIMULTANEOUS OPERATION OF HEATING AND COOLING. V) M O N. THERMOSTATS SHALL START-STOP SUPPLY FANS AND z (A m (n ACTIVATED COOLING HEATING AND OFF MODES AS SELECTED. 0 — U) 6-DUCTWORK. N 0. FABRICATION AND INSTALLATION OF DUCT SYSTEM UNDER THE EXISTING GARAGE DOOR EXISTING GARAGE DOOR LL LATEST EDITION OF SMACNA HVAC DUCT CONSTRUCTION TO REMAIN REMOVE ALL TRACKS AND W Q STANDARD. SECURED PERMANENTLY CLOSED U P. DUCT SHALL BE FIBERGLASS 1" THICK (R-4) MINIMUM. - z F�-- Q. FLEXIBLE DUCTS ARE ALLOWED IN CONCEALED SPACES. VENTILATION EQUIPMENT SCHEDULE -- 0 R. ALL DUCT INSULATION MATERIALS SHALL BE 1" (R-4) MINIMUM. U S. ALL SHOWN DUCT DIMENSION ARE CLEAR INSIDE DUCTS. I Unit Designation EF-1 7-TEST AND BALANCE. g T. CONTRACTOR SHALL TEST AND BALANCE ALL VENTILATION AND AIR CONDITIONING SYSTEMS. Quantity 2 Location Bathrooms Area Served Bathrooms Manufacturer Broan ° Model No 678 0 M FAN 3 Fan Type Bathroom Fan Drive Type Direct o Airflow CFM 50 N Q External Static Pressure inwg 0.10 : ., Fan Speed rpm # MOTOR .. 4�; ,,.. e 1;:. U a E. 8 llzr w `4 0 a Type HANGER STRAP 5'0' MAXIMUM Horsepower HP 00 Q ALLOWABLE DISTANCE , Full Load Amps 0.5 Electrical Service Available 120-1-60 U END CAP W � z DUCT COLLAR `� p MANUAL VOLUME DAMPER W TIE WRAP DUCT COLLAR H w n � REGISTER CAN a w HVAC DESIGN REQUIRES YES NO CHECKED 2 FLEX DUCT CONNECTION DETAILS 3 FLEX DUCT HANGING DETAILS DUCT SMOKE DETECTOR x DRAWN SCALE: NTS. SCALE: NTS. o FIRE DAMPERS X DATE 11-26-2012 SMOKE DAMPERS X COMM.NO. 12-201 FIRE RATED ENCLOSURE X p J FIRE RATED ROOF-FLOOR CEILING ASSEMBLE X FIRE STOPPING X DESIGNF BY: HVAC DUCT SMOKE CONTROL X ENERGY SOLUTIONS FBPE Cert of Authorization 29476 I 4445 W 16th Ave Ste 306 04-14- 013 Hialeah, Florida 33012 Phone: 305-219-0650 Fax:305-200-0157 En.ricLw Pascue.l FE 10739 adminQ_hvao-energysolutions.com *5 VILLAOE EY PATE s ' ZONING ` S1 RUCTU R.A!_ ELEMICA,L ' 7a 6 i F'LUAhB!P��� MECHAKIC,4L _ BLDG. SUBJECT TO COMPLIANCE WITH ,ALL STATE AND COUNTY RULES ANC) REC''LAT',C