Loading...
RC-3-13-632_Plans .................................................................... .................................... .............................. .......................... .......................... ................................................................................. .......................... ............ ............ ...................... . ............ ............. ................................ ........................ .......... .................. ............................................. ...... ................................. ........................... .......................... ..................................................... ............ ............... .............................................. REVISION .................. ........ NO. DATE DESCRIPTION -,A------------ �A ------- ........... ........... ------ .......... ........... THESE D;RAWiNGS AND SPECIFICATIONS ARE PART OF THE CONTRACT O+XUVIENT, PLEASE VERIFY ALL THE DETAILS WRITTEN ON EACH SHEET. FAILURE BY THE GENERAL. CONTRACTOR ........... TO FOLLOW nl -IE DRAWIN'G PLANS AND TS SPECIFICATIONS SHALL NOT BE CAUSE FOR ADDITIONAL WORK BY THE ENG tNEER, COORDINATION OF THE WORK, AND OF THE SUBCONTRACTORS IS THE RESPONSIBILITY ---------- OF THE GENERAL CONTRACTOR, .......... SHEETS INDEX JOB NUMBER AR— 2006— 01 CA 48 boun b&ft pia mg It's the Law! 1--WO-432-47M Sunah'ne State One Call Of Fl 0 do, Ina. ........... ......... . ................................ ............ ........... COVER SHEET . . . . . EXIST. FLOOR PLAN A-1 0 0 -......... i A PS PROPOSED FLOOR/ELEV. . . . . . A-2 m (L ........... z > z PROPOSED ELECT. PLAN . . . . . A-3 •............ > 0 I r� � w { EXIST/ PLUMBING . . . . . A-4 m 0) uj NL � U LTIN ONS G , LL C . z (D PROJECT FOR : lz m 0 Lli z 0 > INTERIOR REMODELING .......... E-4 PROJECT NAME : LLJ 0 -� �' °C 0;u 0 ----------- .......... LD z LLJ PROJECT LOCATION : 163 NW 101 T . __: '� o cl u Q0 ............t MIAMI SHORES FL . ........... ........... ----------! 4 ........... ............ ......................... ------------- ---------------- .....—------------------------ ....... DATE: 02/25/2013 II SCALE: 1/4" =V-O" .......... .........................M-A-N-A-G--E-R A ou U C--A----R-D----- DESIGNER7P OJECT APPROVED BY ARSHAD VI AR PROJECT NO. 2006-11 ............. ........... CKECKED BY: AL SHEET NO. COVER ENGINEER OF RECORD ........... ARSHAD VlQAR FL. 1410ENSE j 38663 1175 N.E. 125TH STREET SUITE 610 TEL: (786) 663-9439 ----------- ---------------------------------------------- ............... ------ ............... --------------- ----------------------------- —----- .............-............................................ ............................................................................................................................... .......-........... ............ ............ ...................... ............. ............ .......... .............. ............. .....................................................................................................- .................................................................................... .......................................... ............. ion(IONd lVN0uvon03NS3aoinV NV AS 03onaONd 0C.-O I -Cl("1710710- I OnWA -i-jnr)lAl 0AAn ")-lI nKil I -Ikl :3 1 /\Y V SI"✓�i w./' f I \f V w \V' I +✓I,J y'I f\ Aa V•./4✓I \1 141/1\/\it 1 1\9/d I V 1 i+�is Ftr' d ( .�+. 4 F 1 1 REVISION I ........... - __........._ _.... -- _... _.-..... - _... _...... __...._ i_ NO. DATE DESCRIPTION SCOPE I-----OF _WORK NOTES: EGRESS DOORS SAFETY NOTES: INTERIOR REMODELING �. Ga-,¢- J . .. ?°>` EGRESS COORS USED AS AN EXIT DOOR SHALL PROVIDE A _......_.._..._..._.ry-.._..._�_ ;AlirJDE-IbV'S cs EX"TE.RIOR DOORS CLEAR OPENING OF NOT LESS THAN THE WIDTHS SHOWN IN TABLE 100L4C. T ', "1 V •1 BATHROOM '1 r Y FIXTURES f• -� •••• � f`� �'a I T p ! THE MAX:MEL1M LEAD 0i DTH OF' THE DOOR SHALL NOT EXCEED 48 INCHES I i T -._...... 1-EXIS I . IX I DIES I O DE PEIOVED .. .}„I REQUIRE PRODUCT APPROVAL ;121 �,:�,}. EGRESS DOORS USED IN THE, EXIT ACCESS SHALL. �...... _. AND SEPARATE PERMITS.s LESS THAN 32 INCHES (813rnnn) `'VIDE AND REPLACED I3l' i�1E�V FIXTURES, EXIST. PVf;'S T4 REMAIN PROVIDE A CLEAR OPENING OF NOT _.. 2. MNI OINS AND EXTERIOR DOORS T kA NON IPAPACT RESISTANCE REQUIRE EXCEPTIONS: SHUTTERS WITH SEPARATE PERMITS 1 . RESIDENT SLEEPING ROOM DOORS `'AljE•iIN GROUP 1 RESTRAINED OCCI. PANCIES. - `,w EXIST.. Ali?< I0JI30�Y TO L3 RcIOI3 I -- 2. STORAGE CLOSETS LESS THAN 10 S0. FT. (0.93 m-2) 1N AREA, AND REPLACED BY 3` 0>, DOOR FRENCH !./...-_l.._.._...__.____._._._._...._.... _.___...__________....._... .__ PATCH AND PAINT TO MATCH THE EXIST. WALL 3. REVOLVING DOOR. -" 4. INTERIOR EGRESS DOOR WITHIN A DWELLING UNIT WHICH !S NOl' REQUIRED � 'I TO BE ACCESSIBLE., 3-EXIST. NON-BEARING PARTITION WALL TO BE REMOVED 5. AGRICULT(JRAL BUILDING. E _. AND REPLACED BY HALF WAIL (PATCH AND PAINT TO EGRESS DOORS SHALL BE SIDE SWINGING TYPE. DOORS 'aIATCH THE EXIST. WALL) r L � _-- - HALL SWING IN THE DIRECTION OF EGRESS FOR THE FOLLOWING; I....----------_--__---------.------.---._-_---_. ...... 1. WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE, OR -"""----"" 2. WHEN SERVING A HIGH HAZARD OCCUPANCY. 3. WHEN USED IN AN EXIT ENCLOSURE. ............ PER F.B<C, 1012<1.2 _..... SAFEGUARDS. ............ _.. , ._,._............................................................. . ........... GENERAL CONTRACTOR NOTES 1. THE GLAZING IN SLIDING AND SWINGING DOORS AND r THESE DRAWINGS AND SPECIFICATIONS .•... c.: >: . .:: ., ..,.,a:«; o..,:..:a: a a:a ac c ccacsc::a:c: c :aa a:.ou a:caoaaa cuuauc c IN S!'40� ER TO :UB ENCLOSURES, INCLUDING ANY ARE PART OF THE CONTRACT DOCUMENT. PLEASE GLAZING WITHIN 60" OF THE FINISHED FLOOR VERIFY ALL THE DETAILS WRITTEN ON EACti SI•im. NOTES SURFACE IN WALLS SURROUNDING ANY TUB OR SHOWER FAILURE 3Y THE GENERAL CONTRACTOR ------------ c,< TO FOLLOW THE DRAWING PANS AND ENCLOSURE, SHALL BE SAFE-7Y GLAZING AS SET FORTH ITS SPECIFIGAIGNS SHALL NOT SE CAUSE FOR FLORIDA BUILDING COiE ADDITIONAL 'WORK BY THE ENGINEER. COORDINATION OF THE FORK, AND ALL FINISH WORK TO BE DONE AS TO ELIMINATE ALL OBSTACLES TO CLEANINGS 7_. OPF.:RA3T..E OR NON-OPERABLE GLAZE PANELS LOCATED OF THE SU3CUNTRACTORS IS THE RESPONSISIUTY ADJAC=ENT .TO A DOOR IN Ir"HE SAME PLANE SHALL BE G" THE GENERAL CONTRACTOR. - 2) ALL ELECTRICAL CONDUIT MUST BE CONCEALED IN WALL, ABOVE THE CEILING OF SAFETY GiAZING WHERE THE NEAREST „R I J ::R THE FLOOR, UNLESS OTHERWISE REQUIRED BY CODES E - 4r D r 1n EDGE OF THE. GLAZING MATERIALS IS WITHIN 12" --------- ? 3} AL SURFACE r ENETRATIONS, (RACKS MUST BE SEALED. ALL. EXISTING SURFACE. FROM THE DOOR IN' THE CLOSED POSITION AND - THAT HAS CRACKS, HOLES TO BE FIXED. ALL FLOORS, 'NALL. TO BE SMOOTH WHOSE BOTTOM EDGE IS LESS THAN 4.8" FROM JOB NUMBER A Cad 48 bye pa,,a� _...... It's the Law! BACKING FOR WALL-HUNG FIXTURES NOTES APPLICABLE ITEMS OF CHAP.3 OF FBC. R-2010 j 1- u Sunshine State Ore Call Of Ficrida, Ine• - - = L ._ .......- ...._RE: DO ORS AND OP ER ATIV E WIN DO WS I N EXTERIOR W ALL THE G F LS, SWINGING N� OPERATIVE WINDOWS IN EXTERIOR WALLS, INCLUDINGTHE SUPPORTING MEMBERS SHALL BE E i I I BASED ON THE PROPOSED USE-HEIGHT ABOVE GRADE IN ACCORDANCE WITH CHAPTER 16 (HIGH VELOCITY 1-1URRICANE ZONES.) AS PER F3C R--2010 SE=CTION 311.4.1 -- T : r V Fixlures shall be spaced as per Figure R307.1 Space required. a ........... , R.U7,2 � I O R3071 Bathtub and shower space. v O _ BATHTUB AND SHOWER I C a EXIST. FLOOR AND 'WALL ABOVE BATHTUBS WITH INSTALLED SHOWER HEARS A H oMPARTr�ENT SHALL BE FINISHED WITH A NON -ABSOBENT SURFACE AND IN SHOWER C v COVERED SUCH SURFACE SHALL EXTEND TO A HEIGHT OF NOT LESS THAN z ....._... PORCH 6 FEET (1829rr•n1) ABOVE FLOOR 03 ® - -�"� ✓�'`� _ F �- -- ~�.�_ -- MOISTURE RESIST GYPSUM 'WALLBOARD SHALE_ NOT BE USED AS A BAKER BOARD -� EXIST. SH24 WINDOW `I O BE REM VE- `--`. - d� _ � S x � i 1� DIRECTLY BEHIND TUB T`:..E, OR SH04JF=f2 AREA Y Z — AND REPLACED BY 3'-0" DOOR � D � PATCI; AND PINT TO MATCU.,-T119--EX1$T. WALL, vl I n C Y EXIST. 3SH-.24 I _ ... ` v STET' STEP !� 4 - -1 I s F.LUC-I CAL • r? •�i + N ,,..'', '- 2 i I : .ER AND DISCONNECT° ;� z f I m O x CIS °,4' F- - -" — ; � . - � - 2!-2`X2'-2T' Iti"0`v w;a i�xIST. x� Ex ( z C Q �N l4 - a _. _ ..._......._.� t l L4 r - " 1 _. � . .c z OF EXIST. c�PENr:Nix `',- I � N TO BE ENCLOSED - -.. J O \\II w F®&2 I $TALIATION a :� l' f 1T? ONLY T') _._..._. O z^� BE REMOVED AND A•. l hEL�I,.A.CETD IB'k i�IE .. �..f .. L� ,,.." b`.... ......... ......... ......... ......... ......... ....,... ! Y _IJJ ___ w , 'l l �V' E IIVt� TK/�€ HO �SET o o �f-j = ;\ ;' �FIU1E5PL5 - I .� L� EXIS - - I ® II I� r`I OFFICE fI I O © EXIST. AIN ( AND ALL APPLIANCE. o a ,� L� ; �) EI r. c °e O _ _ `�... _ L T I I rO � RE I0i1'ED iu BATH H E U _ .. DINING ROOM � � � � I � (L ��W �; I n REPLACED BY Z I Ei E ! EXIST. _ . _.,. �.-.. _ .._ i EXIST. \ EXIST. r:FIST. I3:aTIIcO z EFe€O�ED e§NI? REPLACED T'TkI'Lt�ES ONLY i'C3 j ti G^ I 1 FAMILY ROOM PARTITION� WALL "�O BE E E � KITCHEN �� -- f � LrAt�. BATCH I �. , ' i , f REP REPLACED I3Y w I RE (3�EI3 AND i I - AND PAINT TO MATCH E ii �..... I THE EXIST,...WA��)...__..'ff ` � P 0 E � I _.s , M,< , .......... �A1:I s -' EXIST LXI�T C �,�I` ; ,���t�� r D`�I"H _. :<, '' REMOVED ��� �;LO CIaO. f _... ,;E { t xlsT. TITCrIE ` ABBREVIATIONS _ 'NTRANCE _....,.._.._.,.__.. . __._.. I ................... e 15 T E 2'-2'X2:­,' , DESCRIPTION I ADRREV J -Y^ x ABOVE FINISH FLOOR i EXIS I ^� A<lE<F r I . IF!RE PLACE g C CE' NGG f \% _ _.,_ �r EsXIs,r. C 1.r ON( RF�1 E tiaASCNT�Y ur�rr EXIST. _ EXIST. BEDROOM co CLEANOUT I ........... GARAGE LIVING ROOM � " I "--"""-" .__..__ CUNT. C0N'1'INUCU5 GUFF CORRIDOR T CAL I COi..D 1NATER i.,Ir�E yy r 1DRAINING ' I I ' EXT E:XTERICR I I \ EL EL IENA710N I { J I EP FIN. FL, FINISH FLOOR ! ,. ✓ ,z ., -- E X ST G•C GENERAL CONTRACTOR c. .a GYPauE,� 4�ALL BOARD 1 ........ I I 1-2 DATE.-r r i E HCPD HANDICAPPER ' •\ ,... !i E SC�.I.�. � 1/4" .-1'-0♦ v H.W,L HOI _ ! , i _. HVAC H EATING/J�.NTILAT ON �1i D EXIST. INS>1L INSUL.ATI B LINE i I r�� iGT�L�Rjaa` icyi .. . Iat� ` ......... PORCH n APPROVED BY ARSHAD VIQAR _.... E : 3T JUNCTION BOX I IAY LAVATORY PROJECT NO. 2006--11 O.C. ON CENTER CI�ECI{ED BY: AL OH OVERHEAD _......._...................................................................._._..._._....._.-._. _....._. _ E ` ...................... . PLY'WD. SHEET Nc�. A-- 1 Ref REFRIGERATOR I € ei f. REINFORCED E ENGINEER OF RECORD EXIST/DEMOLITION PLAN ���. STANDARD ! II °I'��T�. TYPICAL ! SCALE: 1/4" = 1' / Wr1i� W/0 WITHOUT E ARSHAB VI 12 QA �i'/P WATERPROOF FL, LICENSE # 38863 1175 N.E. 125TH �i'TRE1✓T SUI'I'I'� 810 r ------ --------------- TEL,: (766) 663--9439 t at .lanaoad ` VNICIuvono3 N193aolnd NV AS a3anaoad aC•c I -C1 n7fnC14,- I OnW J '1:3r1nEA1 nnnn—'N'll nKu E 1nE—:3- - I IwvvvL_v u I r'[,■ rw 1 vva—vI♦ a_vW C*%I1vi1CAL. I 1 VUVV I REVISION ZONING DISTRICT: SINGLE FAMILY LEGEND (MATERIALS INDICATION) SITE TO BE FILLED TO COUNTY FLOOD ELEVATION NO. DATE DESCRIPTION SCOPE OF WORK N.G.V.D. OR AN ELEVATION NO LESS THAN THE HIGHEST EGRESS DOORS SAFETY NOTES: APPROVED CROWN ELEVATION OF THE ROAD ABUTING THE PRO- INTERIOR REMODELING APPLICABLE BUILDING CODE SYMBOL DESCRIPTION EGRESS DOORS USED EXIT DOOR SHALL PROVIDE „ AREA ADJACENT TO LAKE OR CANAL TO BE GRADED SO AS CLEAR OPENING OF NOT T LEE SS THAN THE WIDTHS SHOWN I N TABLE 1004. I—EXIST. BATHROOM FIXTURES TO BE REMOVED FBC 2010 NEW 4 PARTITIONS WALL TO PREVENT DIRECT OVERLAND DISCHARGE OF STORM WATER THE MAXIMUM LEAF WIDTH OF THE DOOR SHALL NOT EXCEED 48 INCHES (1219 mm). EGRESS DOORS USED IN THE EXIT ACCESS SHALL INTO LAKE OR CANAL. PROVIDE A CLEAR OPENING OF NOT LESS THAN 32 INCHES 81 AND REPLACED BY NEW FIXTURES, ALL EXIST. PVC S TO REMAIN EXIST. 4" PARTITIONS WALL LOT WILL BE GRADED SO AS TO PEVENT DIECT OVERLAND ( 3mm) wIDE. DISCHARGE OF STORM WATER ONTO ADJACENT PROPERTY EXCEPTIONS: 2- EXIST. SH24 WINDOW TO BE REMOVED EXIST. 8" CBS WALL .APPLICANT WILL PROVIDE CERTIFICATION PRIOR TO FINAL. 1. RESIDENT SLEEPING ROOM DOORS WITHIN GROUP I RESTRAINED OCCUPANCIES. IN ADDITION TO THE REQUIREMEMTS OF THIS PERMIT,THERE 2, STORAGE CLOSETS LESS THAN 10 SQ. FT. 0.93 m 2 IN AREA. AND REPLACED BY 3'-0" DOOR FRENCH MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY ( ) THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. 3. REVOLVING DOOR. PATCH AND PAINT TO MATCH THE EXIST. WALL SECTION 553.79(10)FLORIDA STATUTES 4. INTERIOR EGRESS DOOR WITHIN A DWELLING UNIT WHICH IS NOT REQUIRED A SEPARATE PERMIT WILL BE REQUIRED FOR ALL DRIWAY TO BE ACCESSIBLE. 3-EXIST. NON-BEARING PARTITION WALL TO BE REMOVED APPROCHES ON TO THE PUBLIC RIGHT OF WAY. 5. AGRICULTURAL BUILDING. AND REPLACED BY HALF WALL PATCH AND PAINT TO THE HEIGHT OF FENCES ,WALL AND HEDGES SHALL NOT EXCEED 2.5 FT IN HEIGHT WITHIN 10 FT OF THE EDGE EGRESS DOORS SHALL BE SIDE SWINGING TYPE. DOORS Q MATCH THE EXIST. WALL) OF ANY DRIVEWAY LEADING TO A RIGHT OF WAY.THE HEIGHT SHALL SWING IN THE DIRECTION OF EGRESS FOR THE FOLLOWING: OF FENCES IS BEING MEASURED FROM GRADE. 1. WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE, OR NOTES. .......... 2. WHEN SERVING A HIGH HAZARD OCCUPANCY, IRRIGATION NOTES: 3. WHEN USED IN AN EXIT ENCLOSURE. PER F.B.C. 1012.1.2 1. WINDOWS & EXTERIOR DOORS SEE PLUMBING PLAN FOR LOCATION OF WATER HOSE OUTLETS,SUCH THAT REQUIRE PRODUCT APPROVAL NO PART OF PROPERTY IS MORE THAN 75FT FROM WATER HOSE OUTLET. SAFEGUARDS, AND SEPARATE PERMITS GENERAL CONTRACTOR NOTES BACKING FOR WALL-HUNG FIXTURES NOTES 1. THE GLAZING IN SLIDING AND SWINGING DOORS AND 2. WINDOWS AND EXTERIOR DOORS THESE DRAWINGS AND SPECIFICATIONS IN SHOWER TO TUB ENCLOSURES, INCLUDING ANY ARE PART OF THE CONTRACT DOCUMENT„ PLEASE NON-IMPACT RESISTANCE REQUIRE ' WHERE WALL-HUNG FIXTURES ARE PROVIDED, 2"x4" BRACING GLAZING WITHIN 60" OF THE FINISHED FLOOR VERIFY ALL THE DETAILS WRITTEN ON EACH SHEET. SHUTTERS WITH SEPARATE PERMITS BETWEEN STUDS,AT POINT OF ATTACHMENT OF FIXTURE, SHALL SURFACE N WALLS SURROUNDING ANY TUB OR SHOWER FAILURE BY THE GENERAL CONTRACTOR BE PROVIDED TO WITHSTAND 200LBS FORCE APPLIED IN ALL ENCLOSURE, SHALL BE SAFETY GLAZING AS SET FORTH TO FOLLOW THE DRAWING PLANS AND DIRECTIONS (OR SUPPORTS BE PROVIDED AS PER FIXTURE IN FLORIDA BUILDING CODE ITS SPECIFICATIONS SHALL NOT BE CAUSE FOR MANUFACTURERS REQUIREMENT ADDITIONAL WORK BY THE ENGINEER. ) COORDINATION OF THE WORK, AND PROTECTION AGAINST TERMITES 2. OPERABLE OR NON-OPERABLE GLAZED PANELS LOCATED OF THE SUBCONTRACTORS IS THE RESPONSIBILITY BATH ROOMiC LOS ETS DOORS SAFETY NOTES ADJACENT TO A DOOR IN THE SAME PLANE SHALL BE OF THE GENERAL CONTRACTOR. 1. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN OF SAFETY GLAZING WHERE THE NEAREST CAN OPEN THE DOOR FROM INSIDE THE CLOSET. EDGE OF THE GLAZING MATERIALS IS WITHIN 12" AS PER 8320.01-FBC-2010 2. EVERY BATHROOM DOOR SHALL BE DESIGNED TO ALLOW OPENING FROM THE DOOR IN THE CLOSED POSITION AND Termite protection shall he provided by registered - FROM THE OUTSIDE DURING AN EMERGENCY WHEN LOCKED. WHOSE BOTTOM EDGE IS LESS THAN 48" FROM ` " JOB NUMBER AR- 2006- 01 ;emit€cider, including soil applied pesticides, baiting systems, .€ __.... ..._. .... - - and pesticides applied to word, or Other approved methods of EGRESS WINDOW SPECIFICATIONS ZONING LEGEND termite protection l!abei(-.,d for use as a preventative treatment to NOTES AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT R-2 b&n7-4 new c:on.m.uction Upon completion of the application of the temy.;te protective THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS p be p THAN 20IN IN WIDTH, 24IN IN HEIGHT AND 5.75 SQ FT IN AREA It's the Law! SITE TO BE FILLED TO COUNTY FLOOD ELEVATION 7 treatment, B certificate of corr�.plianCEa Shall be issued to the 1) ALL FINISH WORK TO BE DONE AS TO ELIMINATE ALL OBSTACLES TO CLEANINGS THE BOTTOM OF THE OPENING SHALL BE NOT MORE THAN 44IN A.F.F. N.G.V.D.OR AN ELEVATION NO LESS THAN THE HIGHEST Sunshine State One C40fFl da, Inc, building department by the licennsed pest control COrrpariy that APPROVED CROWN ELEVATION OF THE ROAD ABUTTING THE PRO- contains the following statement: "The building has received a 2) ALL ELECTRICAL CONDUIT MUST BE CONCEALED IN WALL, ABOVE THE CEILING EGRESS DOORS SAFETY NOTES: complete treatment for he prevention of subterranean termite; OR UNDER THE FLOOR, UNLESS OTHERWISE REQUIRED BY CODES AREA ADJACENT TO LAKE OR CANAL TO BE GRADED SO AS t NO DOOR IN ANY MEANS OF ESCAPE SHALL BE LOCKED AGAINST TO PREVENT DIRECT OVERLAND DISCHARGE OF STORM WATER Treatment is in accordance with rules and la.-vs established by 3) ALL SURFACE PENETRATIONS, CRACKS MUST BE SEALED. ALL EXISTING SURFACE EGRESS WHEN THE BUILDING IS OCCUPIED. ALL LOCKING DEVICES INTO LAKE OR CANAL. the Florida Depatment of Agriculture and Consumer Services." THAT HAS CRACKS, HOLES TO BE FIXED. ALL FLOORS, WALL TO BE SMOOTH THAT IMPEDE OR PROHIBIT EGRESS OR THAT CANNOT BE EASILY LOT WILL BE GRADED SO AS TO PREVENT DIECT OVERLAND DISENGAGED SHALL BE PROHIBITED, DISCHARGE OF STORM WATER ONTO ADJACENT PROPERTY ALL WINDOWS TO BE PROTECTED WITH DADE COUNTY APPLICANT WILL PROVIDE CERTIFICATION PRIOR TO FINAL. PRODUCT CONTROL APPROVED STORM SHUTTERS. IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT,THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. SECTION 553.79(10)FLORIDA STATUTES A SEPARATE PERMIT WILL BE REQUIRED FOR ALL DRIVEWAY ABBREVIATIONS APPROACHES ON TO 7 H PUBLIC RIGHT OF WAY. -� U THE HEIGHT OF FENCES ,WALL AND HEDGES SHALL NOT EXCEED 2.5 FT IN HEIGHT WITHIN 10 FT OF THE EDGE ® EXIST. ABBREV. DESCRIPTION OF ANY DRIVEWAY LEADING TO A RIGHT OF WAY.THE HEIGHT 0 COVERED OF FENCES IS BEING MEASURED FROM GRADE. n o. PORCH A.F.F ABOVE FINISH FLOOR BLDG BUILDING Z EXIST. SH24 WINDOW TO BE REMOVED CIg CEILING APPLICABLE ITEMS OF CHAP.3 OF FBC. R-2010 W O AND REPLACED BY 3'-0" DOOR CMU CONCRETE MASONRY UNIT RE: DOORS AND OPERATIVE WINDOWS IN EXTERIOR WALL z PATCH AND PAINT TO MATC0_THF,�-� LW$T. AL CO CLEANOUT ! , D Q THE DESIGN AND APPROVAL OF SLIDING DOORS, SWINGING DOORS AND OPERATIVE V CONT. CONTINUOUS WINDOWS IN EXTERIOR WALLS, INCLUDING THE SUPPORTING MEMBERS SHALL BE ® EXIST. 3SH-2 STEP CORR CORRIDOR BASED ON THE PROPOSED USE-HEIGHT ABOVE GRADE IN ACCORDANCE WITH CHAPTER C•� COLD WATER LINE 16 (HIGH VELOCITY HURRICANE ZONES.) AS PER FBC R-2010 SECTION 311.4.1 � —� O CWL YSTEP ELECT ICAL DWg DRAWING SECTION R307 (�� m N L X o METER AND DISCONNECT EXIST. 3 Z 0 0) w R9 Z U EXT EXTERIOR TOILET, BATH AND SHOWER SPACES m 0 w iy � EXIST. 2" "X2"-� ' EXIST. O SH-24 ��V�12 NDO SH-24 EL ELEVATION Fixtures shall be spaced as per Figure m 1 ' 2'-2" OF _ - - FIN. FL. FINISH FLOOR I"" C EXIST. OPENING I R307.1 Space required. Q N TO BE ENCLOSED G.0 GENERAL CONTRACTOR 8.07.2 Q n Z = FOR IN I Y EXIST. BATHROOM R307.1 Bathtub and shower space. '°'� Q N OF NEW 36" DOOR i ONLY TO G.W.B GYPSUM WALL BOARD O BE REMOVED AND HCPD HANDICAPPED BATHTUB AND SHOWER U) Q >' c� EXIST. - ---------- REPLACED BY NEW HVAC HEATING/VENTILATION FLOOR AND WALL ABOVE BATHTUBS WITH INSTALLED SHOWER HEARS �J Z m x - OPENING - EXIST. KITCHEN O FIXTURES, PVC's AND IN SHOWER COMPARTMENT SHALL BE FINISHED WITH A NON-ABSOBENT SURFACE Z ►-� A a w N I TO BE } SINK/DISH WASHER �1� =_�� N EXIST. H.W.L HOT WATER LINE I- I ® t- INSUL INSULATION SUCH SURFACE SHALL EXTEND TO A HEIGHT OF NOT LESS THAN W � LU I I CLOSED AND ALL APPLIANCE O i i� rL,� ))EXI OFFICE 6 FEET (1829mm) ABOVE FLOOR lu U N _ LJ EXIST. TO BE REMOVED AN �� I ILI BATH JT JUNCTION BOX MOISTURE RESISTANT GYPSUM WALLBOARD SHALL NOT BE USED AS A BAKER BOARD ( � o - DINING ROOM REPLACED BY N I LAV LAVATORY DIRECTLY BEHIND TUB TILES OR SHOWER AREA v w O - I I ir>-i I EXIST. O.C. ON CENTER 0 .� O 0 n a EXIST. EXIST. NON-BEARING j EXIST. LL-J BEDROOM #I T j = x OH W PLYWOOD TERMITE PROTECTION O Z `� x FAMILY ROOM PARTITION WALL TO BE I I KITCHEN I N PLY D. cn I I I A REMOVED AND REPLACED I i I I i i -t Ref REFRIGERATOR AS PER 84409.13.5-FBC-2010 f-1 BY HALF WALL (PATCH r-�--1 I einf. REINFORCED W AND PAINT TO MATCH � � Do BY ALL BUILDINGS SHALL HAVE APRE-CONSTRUCTION TREATMENT PROTECTION I I cn- STD. STANDARD AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED BY THE EXIST. WALL) I i II m= I -"// ,? TYP. TYPICAL THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE O LL---- lJ11LCJ1L W/ WITH DEEMED AS APPROVED WITH RESPECT TO PRECONSTRUCTION SOIL TREATMENT FOR (.j_ I' -3•- ;I �`� W/0 WITHOUT PROTECTION AGAINST SUBTERRANEAN TERMITES, A CERTIFICATE OF COMPLIANCE I 3'-0" OF EXIST. EXIST. y< EXIST.,_ r� W P WATERPROOF SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL EXIST. > t ,.1= �nl / COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: THE BUILDING HAS RECEIVED NON-BEARING CLO. CLO. ,� �� BATH(C �� li li A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. m PARTITION ��jl TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY WALL TO THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. REMOVED R311.5.4 LANDING FOR STAIRWAYS FOR NEW EXIST. KITCHEN Z-2"X2'-2" ENTRANC WINDOW FLIGHT OF STAIRS, PROVIDED A DOOR DOES NOT SWING OVER THE STAIRS. i m EXIST. EXCEPTION. A FLOOR OR LANDING IS NOT REQUIRED AT THE TOP OF AN INTERIOR EXIST. A THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. a D !FIRE PLAC� LIVING ROOM Q i I A FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL RISER GREATER THAN 12 FEET(3659mm) BETWEEN FLOOR LEVELS OR LANDINGS °Q p° EXIST. BEDROOM #2 THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE STAIRSWAY GARAGE SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36" (914mm) MEASURED IN THE DIRECTION OF TRAVEL. i � I i O i STEP z I I EXIST. I I SH-24 DATE: 02/25/2013 I I SCALE: 1/4" =1'-0" I I EXIST. ESIGNER PROJECT AGE A. BOUCARD ----------------------- PORCH APPROVED BY ARSHAD VIQAR PROJECT NO. 2006-11 CKECKEID BY: AL SHEET NO. A- 1 EXIST/DEMOLITION PLAN ENGINEER OF RECORD SCALE: 1/4" = 1' ARSHAD VIQAR FL. LICENSE # 38863 1175 N.E. 125TH STREET SUITE 610 TEL.: (786) 663-9439 ionGONd IVNouvo 143 msmoinV NV As 03Of1 and rani -Cl n710710- I :3nW-A -1:3nn1A1 OAhrl "VI-1 nNii i -IN] ::3- - ��:� ���� �,�M� a ,�' I I vv.4vev u I rwlr r-N'+s I %0 LiL.%01 LrIJ%.0W0-1I iLIIV%9- I I vSJV I '. LEVEL 2 ALTERATION : REVISION LEVEL 2 ALTERATION INCLUDE THE RECONFIGURATION OF SPACE NO. DATE DESCRIPTION THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, EXIST. RAFTER 04-14-2013 DETAILS,DOOR PRESSURE ; THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, EXIST. WOOD BEAM OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT USE: (2) CARBON Tr:la C F 'I HE BE.�C1 BOLTS W NUTS IN `•� R T / YREPLACED EACH CONNECTION € o XIST S,H24 TYP ` BE REMOVED AND ( ) BY 36"FRENCH DOOR NEW (2) 2"X� O" i/ � EXIST. I I 2'-2,:X2,-2„ WINDOW TO REMAIN EXIST. 3SH-24 EXIST.SH-24 TO REMAIN TO REMAIN Q NEW 3„X3"X ° WOOD POST (TYP) FINISH FLOG ------------------------------- ------------------------------------------------ EXIST. RAFTER WOOD HEADER DETAIL N.T.S E)Y(IST. BAU"NK" 01"URTH) ELEVATIU1,41 > z — GENERAL CONTRACTOR NOTES THESE DRAWINGS AND SPECIFICATIONS EXIST. OOD B AM NEW TWISTED STRAP x ARE PART OF THE CONTRACT DOCUMENT, PLEASE �,.�- LE: 1,''4 € VERIFY ALL THE DETAILS WRITTEN ON EACH SHEET. USE TWISTED NVTR-20 FAILURE BY THE GENERAL CONTRACTOR GAUGE 14 TO FOLLOW THE DRAWING PLANS AND NEW (2)' 2"XIO'N W/FASTENERS ITS SPECIFICATIONS SHALL NOT BE EECAUSE FOR • • AND 14(16d NAILS)ON EACH MEMBER NOA:08-0326.11 COORDINATION OF THE WORK. AND OF THE SUBCONTRACTORS IS THE RESPONSIBILITY MIAMI DADE COUNTY (TYP.) OF THE GENERAL CONTRACTOR. USE: (2) �" CARBON 3'—O" BOLTS W/NUTS IN EACH CONNECTION JO BE — — OPENING i (TYp) All- bcfm y-dig EXIST. 2"X6" STUDS TO _ 1-800-432-4770 It's the Law! STUDS TO REMAIN TYP '"'�P OF Tllc c,�'�I'.• REMAIN (TYP) NEW 3"X3"X i" / (TYP) ZONE 4 Sunshine Stote One Call Of FI Ido, Inc. WOOD POST (TYP) WIND PRESSURE 2-j" RED HEAD BOLT �� I NEG. : -43.5 W/6"X6"Xi" PLATE / / NEG. : 43.56 /6"EMB �,,. EXIST. NEW 21-2°X2'-2„ EXIST. FLOOR I 06" FRENCH DOOR WINDOW L----------------------------------------------------------- EXIST. 3SH-24 RENCI NOA#12-0308.40 TO REMAIN EXIST.SH-24 TO REMAIN IMPACT TO REMAIN WOOD HEADER DETAIL �R CAT a •,� CAT II - FINISH FLOOR O V N.T.S ::: 0 C m J OREVSED ,3 EXIST. DOORS SCHEDULE a COVERED WIND LOAD -t ZID() #5 BAR SUCH FRAME AREA O PORCH SCAB- E: 1f� � ONE STORY BLDG.)D F, ,BAR SHALL BE EXTENDED 6" TYPE s i z s i z e U INTO EXISTING FOOTING AND ( (SQ.FT.) MATERIAL QUANT. (Z4) P-(Z5) P-(Z4,Z5) P+ REMARKS Z I\ TIE BEAM AND HOLE TO BE l NEW BACK DOOR LAS C FILLED W/EPDXY ALL SP ICES I O 3'-0 x 6'-8" 4-31/4 20.0 GLASS 1 43.56 -52.55 40.03 CAT II -� o „ „ U o w Y EXIST. 3SH 2 STEP �I NEbJ ROOF m TF:'tUSS ASSFFA,3LY BY TRUSS MANUF. SEE STEP ��, SEE WALL SECTION � 7C o FOR DETAIL ------------------------ ^ z 0 m O �x o EXIST. (, NE'Y"v ? CEILING 11SU 'TI�Jf \ Z �7 PROVIDES SAFETY GLASSING 2'-2"X2'-' ' J C w N 3 EXIST. Q _ WINDO SH-24 i ; n STEP 7 Q rJ•. D—i _ O \\II N NEW 36" a M = ALUM. FRENCH DOOR �.._ � O iT D !L CN ! -. r EXIST. l 1 w v w DINING ROOM EXIST. ,� ; `� y Ll� z E; w EXIST. EXIST OFFICE ...... 11 t O I ' OPENING ::�.:....;_.., ------f---------------- ... .. _�..1.....- 1.....--.. ................................ .... { j---�/,.,.,` .- C TO O I I BATH i v 1 REMAIN 1 / �- i " „ - EXIST. �. GYP, u, ? .�;4" GIa I?A; FILL WITH CONCRETE n NEW 36 DOOR 4 -0 T O =UPF"NG NC ACSEti3LY i (TYP.) NEW O O EXIST. NEW HALF ALL EXIST. ® BEDROOM #1 o m FAMILY ROOM KITCHEN so = x Il ! ...,'.z. .r' .': �• r' • • "i\� TOP P PLATE r•:* .; <T IIVQ'�16;BE1�Ai . .l '�'..' FILL LL WHERE WITH CONC. 2 O' �, i--- .d ~ 000 s 1-J N I ;.: 2"x,4." BRACING @ MID-HEIGHT; ,` ; �1 3 -o° EXIST. A#2 OPENING CLO. BATH SEE (\ J/BUJ `` (.<C LAYER CF ;�` JT pEr � ' l P S M ' '4 wnu DETAILS ��4 a EACH � I. t �{ f t n v•_ � WALL EXIST. ^.P? ED 'V ERTICALLY OP H0 ,IZONTAL� t 2' 2"X2' 2" AND`N,�,ILEO ,A�:; �,?QLER �n,,.LS z„ To s" � NEW WINDOW {.: r- I O cn m ;,`` ::,'. PROVIDE (1) #5 BAR — MIN' FILL CELL WHERE 1M PINS `•'''•�'; D 0 0 R "•�1'."�� EXISTING H BAR $HALL BE I C, \ q a . �',• EXISTING FOOTING EXIST. ,� 7coo psi '• C*,•;: ARE LOCATED WITH CONC. WALL IFIRE PLAC� r..1•� AND TIOEDBFJM INTO AND �a DQ I I ` •'*y''••I `'f" HOLE TO BE FILLED 6 'r W/EPDXY ALL D4�� EXIST. L-- I EXIST. I f, BEDROOM I SPLICES TO BE 30' I (STING , Y'x4" 'eVOCL) STI IBS � 16" O.C. .� ! ALL GARAGE # EXIST. Ili PROVIDE (1) X15 BAR a ` LIVING ROOM SUCH BAR SH ,;;• , I•I EXTENDED 8" INTO pi EXISTING FOOTING „'�` � j AND TIE BEAM AND SPLICES TO BE 30' %l HOLE TO BE FILLED I;t I W/EPDXY ALL � � � � .. ----_._ Z"X4 BOTTOM O i i STEP 4"',I;.OD >BA,E PLAT j `y.; •':;, W z I I EACH SIDE SLAB UNE SLAB U EXIST. 1/2" NAILING 0 124' O.C. SH-24 CC S S n DATE: 02/25/2013 PvC. LAB EXI .TIN�.� I w I - 4" -1' 0" I I SEI_ 'WALL SLCTIOiV F i -_ � ,; ;' .� .. . .. , •'. �.; .` SCALE: 1/ EXIST. .r '..,•,EkVSTIN-G i'QUNOATIOH ?. „' • ' UCARD - ' DESIGNER PROJECT MANAGER A. BO Lam E9-------------------- PORCH LEGEND APPROVED BY ARSHAD VIQAR (MATERIALS INDICATION) " I�....I. _-..-._-.,.� ----- _-.-_ r.�.. r 1 1-.._L...,.......... T ,::::::::.1:r I t„ :::: PROJECT N0. 2008-11 I---•' : NEW 4' HALF WALL I I� �� �� �� OPENING DETAIL / CKECKED BY: AL SYMBOL DESCRIPTION I L$ — I WTA SHEET NO. A-2 WELL CO-k,�PACIED FILL EXIST. 4" PARTITIONS WALL ' ENGINEER OF RECORD '• PROPOSED FLOOR PLAN 04-30-2013 / EXIST. BEARING WALL SCALE: 1/4" - 1' , YYALL, BEARING (`I"�'"I'IC,��L) REVISED ARSHAD VIQAR FL. LICENSE 38863 0 04-30-2013 # REVISED _4 1175 N.E. 125TH STREET SUITE 610 TEL.: (786) 883-9439 ionaoad IVNOuvanaa �is:iaolnv NV As a3anaoNd a1,•o I -01 m10cI1,- I :3nWA 17(1/IIAI n6An1 N, 1 nAII 1-mcmn,)1A( - I 1 1\VVVVL_✓ ✓ 1 r'\1\ rlV I -o V L_\/1\ L.V%o 12 IV I1r%4. 1 1\VV VV 1 REVISION NO. DATE DESCRIPTION I TOP OF THE BEAI1 LEVEL 2 ALTERATION : XIST> LEVEL 2 ALTERATION INCLUDE THE RECONFIGURATION OF SPACE E 0 BE—REMOVED REMOO EMOVED AND REPLACED BY 36"FRENCH DOOR THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, EXIST. 2'_2"X2'-2" > THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM , ,� � rr EXIST. 3SH_24 OIR°MAIN \ /` TO REMAIN EXIST. l OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT r TO REMAIN 0 r . rNf H LOOR EXIST. ELEVATION GENERAL CONTRACTOR NOTES i ;�� " THESE PAR THE DOC SCALE UMENT,ACONTRACT SPECIFICATIONS PLEASE VERIFY ALL THE DETAILS WRITTEN ON EACH SHEET. FAILURE BY THE GENERAL CONTRACTOR TO FOLLOW THE DRAWING PLANS AND ITS SPECIFICATIONS SHALL NOT BE CAUSE FOR ADDITIONAL WORK BY THE ENGINEER. COORDINATION OF THE WORK, AND OF THE SUBCONTRACTORS IS THE RESPONSIBILITY DOORS S C H E D U L_E OF THE GENERAL CONTRACTOR. FRAME AREA WIND LOAD ONE STORY BLDG. TYPE s i z e s i z e (SQ.FT.) MATERIAL QUANT. (Z4) P-(Z5) P-(Z4,Z5) P+ REMARKS O 3`-0"x 6'-8" 4-3/4 20.0 GLASS 1 43.22 -51.87 39.69 NEW BACK DOOR GLASS Boa NUMBER AR— 2ooe- at CAT II 10 Call 48 hoop oel bdon 3—&S TOP OF THEE.BEAM It's the Law! ...._... ^-.._............_..._:..._.........._..._ 1-800-432-4770 ZONE4 8` Sunshine State One Call Of Ft da, Inc. II WIND PRESSURE POS. :go, e3 NEG. : EXIST. NEW 2'-2"X2'-2" a 6" FRENCH DOOR WINDOW EXIST. 3SH-24 RENO NOA#12-0308.40 TO REMAIN EXIST.SH-24 TO REMAIN \`R IMPACT TO REMAIN CAT II CAT II � V _----_ FINISI1 FLOOR O 0 C J EXIST. v Z COVERED I 03 0 PORCH _< Q SCALE: 111`4" 1' z U D LU o C 0 EXIST. 3SH-2 STEP m NEW R ;OF W TRUSS ASSEMBLY BY TRUSS MANIJF:°-°- SEE WALL SECTION 0 STEP FOR DETAIL R1 �XO z o EXIST. : (� NE`W R-1'3 CEJNG INSU€.ATION C Q w C 1 CAOV DES SAFETY GLASSING 2'-2"X2'- EXIST. :::::::::: �. :::-:::::::-::_: ::::::::::--:::-:::...:::::::::::-:::::::-:-:W�:_-:�.:: :::-:::::::::::::-:_-= :�:::::�_::: C7 _ W I N D o _-- - - ::......._...............:..- _ - __...._._...........:..............._..-..... J SH-24 .... - --- --�-..-------. .. Q STEP W N NEW 36" Q 0 = ALUM. FRENCH DOOR I j Z o N I ; D I I O r" v (n v 57< EXIST. DINING ROOM EXIST. ._......�......�_... ....................--._--.-.---.---.--.-.........._..._�_.-. —` , 2� ----_._.._._.._ _....._..._.. 0 0 EXIST OFFICE E-4 _........BATH ...--------- :: ::�: ... . C 1/2" GYP, BRD OVER 3/4" HIGH HAT NEW 36" D00 pr EXIST. €=1 RING f:EILIP�G ASSEMBLY Q EXIST. EXIST. BEDROOM #1 0 z FAMILY ROOM NEW HALF WALL KITCHEN 50 T = x rr Do i i 2"X4" 'TOP PLATE W " O ® 2"x4" BRACING 0 MID--HEIGHT I � LL EXIST. EXIST. EXIST. ; uu�u CLO. CLO. BATH I a , 2 t ONE AYE R OF 5/8 TYPE "X" GYPSUM s...... e4ALLBCARD EACH "iJE. THESE DYERS i• EXIST. - APP L: ED VERTICALLY OR HORIZO JTAI-LY 2'-2"X2'-2'" AND NA:L.ED 'N/ 6D COOLER NAILS 7" TO 9 WINDOW O.C. I EXIST. j EXIST. A 8'-0" rAl`d. !FIRE PLACq LIVING ROOM \ ! oaDo � I I °4 D° EXIST. EXIST. GARAGE BEDROOM #2 2"x4" WOOD STUDS 16" O.C. — 2"X4" BOTTOM O I STEP 4"1100D BASE.----- PLAT'- z I EACH SIDE I EXIST. I I 1/2" NNUNG `.9 24" O.C. SH-24 CONC. SLAB EXISTING I DATE: 02/25/2013 I SEE `NALL SECT 0; IN :€ I I _.._. ...... ...... _ .........._..........-............_. - - ...... SCALE: 1/4" =1'-0, ........._...EXIST. ..... _ ........... .._........ _--.-.-----.-_-._-_--- __--__.._..__........ DESIGNER/PROJECT MANAGER A. B ----------------------- PORCH RD APPROVED BY ARSHAD VIQAR i - PROJECT NO. 2006-11 ,_ I-r CKECKED BY: AL I! I ....._... _T WELL COMPACTED FILL SHEET N0. A-2 PROPOSED FLOOR PLAN ENGINEER OF RECORD SCALE: 1/4" = 1' WALL BEARING (TYPICAL) ARSHAD VIQAR FL. LICENSE # 38863 1175 N.E. 125TH STREET SUITE 610 TEL.: (786) 663-9439 ionaoNd TVN0uvon03 mauoind NV Ae a3anwNd ('C'O i -C i n7/071c- i :3nWA _lnnniAi nnen—�-ll nnu i -lf l :3- �p V ELECTRICAL NOTES REVISION 1). ALL ELECTRICAL WORK SHALL COMPLY W/THE NATIONAL No. DATE DESCRIPTION ELECTRICAL CODE, S.F.B.C. AND ALL OTHER APPLICABLE CODES. 2.) ALL ELECT. WORK TO BE DONE BY A LICENSED ELECTRICAL NOTE: CONTRACTOR AFTER A PERMIT IS ISSUED. EXISTING ELECTRICAL SCHEDULE BUS:150A MB VOLTAGE:120/240,10 3W WET LOCATION NOTES: PROVIDE ARC-FAULT 3.) CONDUIT UNDERGROUND TO BE PVC SCHEDULE 40 1.ALL ELECT. EQUIP. EXPOSED TO WEATHER CIRCUIT INTERRUPTER 4.) CONDUIT EXPOSED TO WEATHER TO BE IMC. LOCATION: OUTSIDE POLE: 25 A.I.0 10,000 A SHALL COMPLY TO NEC 373-2(A) 5.) WIRE INSTALLED ELSEWHERE TO BE ROMEX. LA 2. SWITCHES OR CIRCUIT BREAKERS PROTECTION FOR ALL 15 6.) FLEXIBLE CONDUIT SHALL BE SEAL TITE. DISHWASHER 1500 120 #12 20 NEMA4X IN WET LOCATION OR OUTSIDE OF A BUILDING SHALL BE ENCLOSED AND 20 AMP 125 VOLT 7.) OUTLETS INSTALLED OUTDOORS, GARAGE AND C i r. LOCATION w a tts vo I t s wire C.B. ROMEX re m o rks IN A WEATHERPROOF ENCLOSURE BATHROOMS SHALL HAVE GROUND FAULT INTERRUPTER A/C COMP. 2,055X3w/sq.ft. =6, 1 65.78 BEDROOM BRANCH OR CABINET. PER NEC 380-4 C-1 ,3 8.) ELECTRICAL OUTLETS ( RECEPTACLES AND LIGHTING A/C A.H.0 8,000 240 #10 30 EXISTING 1500 w each circuit , 3. NO SWITCHES SHALL BE INSTALLED CIRCUIT RECEPTACLE BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT C-2,4 OVEN KIT. 12.000 240 #6 50 EXISTING WITHIN WET LOCATION THE HIGHEST PERMITTED CIRCUITS FROM THOSE IN THE HA8ITAL OUTLET. AS PER N.E.0 9.) NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED C-5,7 GARAGE 1500 120 #12 20 EXISTING 210-12 BELOW BASE FLOOD ELEVATION. C-6,8 WATER HEATER 4500 240 #10 30 EXISTING 10.) A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. C-9 REFRIGERATOR 1 500 120 #12 20 EXISTING 11.) MAIN CIRCUIT BREAKERS PANELS SHALL BE LOCATED ABOVE C-10 WASHER 1500 120 #12 20 EXISTING BASE FLOOD ELEVATION. 12.) IT SUGGESTED THAT YOU CONFER WITH FLORIDA POWER C-1 1 SMALL APPL. 1 500 120 #12 20 EXISTING GENERAL CONTRACTOR NOTES & LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH THESE DRAWINGS AND SPECIFICATIONS FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. C-12 KITCHEN GFI 1 500 120 #12 20 EXISTING ARE PART OF THE CONTRACT DOCUMENT, PLEASE VERIFY ALL THE DETAILS WRITTEN ON EACH SHEET. 13) PROVIDE SMOKE DETECTOR AS INDICATED HEREIN. SUCH SMOKE C-13-20 LIGHT & RECEPT. 6,165,78 120 #12 20 EXISTING FAILURE BY THE GENERAL CONTRACTOR DETECTOR SHALL INTERCONNECTED AND SHALL BE POWERED OFF BY A TO FOLLOW THE DRAWING PLANS AND BATH OR KITCHEN CIRCUIT W/ 110 VOLT MIN. WITH BATTERY BACKUP DRYER 5000 240 #10 30 (2000W A.H.U. COOLING) TONS ITS SPECIFICATIONS SHALL NOT BE CAUSE FOR C-21,23 EXISTING KW, HEAT STRIP ADDITIONAL WORK BY THE ENGINEER. COORDINATION OF THE WORK, AND 14) PROVIDE ARC FAULT PROTECTION ON BEDROOM CIRCUITS OF THE SUBCONTRACTORS IS THE RESPONSIBIUTY AS PER NEC. 210-12 C-24 DISHWASHER 1 1 ,500 1 120 1 #12 1 20 1 EXISTING OF THE GENERAL CONTRACTOR. 15) ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLTS, SINGLE PHASE, 15- AND 20-AMPERES RECEPTACLE OUTLETS INSTALLED IN DWELLING C-25 SPARES UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S). JOB NUMBER AR- 2006- 01 AS PER NEC 210-12 (b) SMOKE DETECTOR NOTES ADDITIONAL LIGHTS AND RECEPTACLES Call496urn tn,ou ate C-25 SMOKE DET. 1 500 120 #14 20 ROMEX It's the Law! 7 SMOKE DETECTOR SHALL NOT BE PLACED tIW432-4770 WITHIN 3 FT. OF ANY A/C GRILL. Sunshine State One C40fFI da, Inc. SMOKE DETECTOR SHALL BE HARDWIRED ( 110 VOLT TYPE) TO A NON- SWITCHI,BLE KITCHEN OR BATHROOM LIGHTING CIRCUIT WITH BATTEFY BACK-UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIZE OF GROUND TOTAL WATTS @ EXISTING=36,665.78 WATTS hLULPIAULL QtN 6u rtW CKT CIRCUIT INTERRUPTER ALL SMOKE DETECTORS AND G-FI PROTETED WITHIN EACH UNIT SHALL BE INTERCONNECTED. TOTAL NEW WATTS ADDED FOR REMODELING TOTAL AMPS NEEDED =29,266(240V=121.94 AMPS FOR THE NEW SMOKE DETECTOR=1,500 WATTS SERVICE @ 150 AMPS TOTAL =38,165.78 WATTS THE NEW LOAD WILL NOT INCREASE THE FIRST 10000 WATTS ® 100% =10,000 W THE EXISTING LOAD IN THE PANEL "0 U NO POINT A REMAINING 28,165.78 WATTS @ 40%=11,266 O LONG COUNTER TO BE MORE THAN AIR CONDIT. @ 100% =8,000 WATTS O r FEFT FROM G.F I PROTECTED RECEPTACLE. c I PUT DNV RECEPTACLE UNDER SINK, EXIST. m 0 I o (L COVERED ALL FIXED APPLIANCES ON DFDICATE9 CKT$, `= PORCH z z Q ADa 8MOKUCANDON MONOXIDE DETECTORS, D ANY AND ALL CLOTH AND RUBBER C: pW MULPEO CONDUCTORS TO BE REPLACED, 0 Y EXIST. 3SH 2 STEP_ ELECTRICAL LEGENDS J m° W STEP 0 o ld SINGLE RECEPTACLE 'U p EMERGENCY LIGHT (�^ m 0 x o EXIST, `✓ / V b DUPLEX RECEPTACLE Z C � Ix° 2'_2"X2­ " EX-ST. �� ('� EXIT LIGHT J 0 Q WINDO SH-24 z v 220V RECEPTACLE `U' w Z STEP GFI z Q N NEW 36" DOOR SWITCHED RECEPTACLE \\�� SINGLE FLOOD - SOFFIT MOUNTED Z mN ADD " a QUADRAPLEX RECEPTACLE O �^ tD.. ® EXIST. C-20 EXIST. - .< DOUBLE FLOOD - SOFFIT MOUNTED 2 VJ a .� v w FAMILY ROOM AFCI EXIST. EXIST. SINGLE FLOOR RECEPTACLE , 11J �. p DINING ROOM INCANDESCENT FIXTURE - CEILING MOUNTED C� 0 p ADD BATH [� 1 OFFICE DUPLEX FLOOR RECEPTACLE ``� C INCANDESCENT FIXTURE - WALL MOUNTED v w n a GFI EXI T. SWITCHED FLOOR RECEPTACLE LL• Q EXIST. NEW 36° D00 EXIST. o ® C-25 BEDROOM 1 m ® RECESSED HIGH HAT O ADD KITCHEN F 1 = x QUADRAPLEX FLOOR RECEPTACLE (� EXIST. C-20 EX S° AFCI a -�i e RECESS INCAND. (EYEBALL) FIXTURE ADD AFCI 00 W Z �, C-20 AFCI GFI >0 li �/ SPECIAL PLUG 2L4 2 FT UNDER CABINET �- 0 _� i ,� FLUOR. FIXTURE C-1 2 m= GFI GROUND FAULT INTERRUPTER LL H ADD S� ® e WP WEATHERPROOF GROUND P FLUOR UNDER CABINET � AFCI AFCI EXIST. EXIST. EXIST. G IST. GFI FAULT INTERRUPTER C-20 it C-25 CLO. CLO. BATH ® EP ELECTRIC PANEL 4 FT UNDER CABINET III EW ALL a FLUOR. FIXTURE iv, 2 VP VAPOR PROOF STRIP LIGHT 2'2I X2'-2" 24x48 FLUOR. FIXTURE $ SINGLE POLE SWITCH � WINDOW S° = X 12x48 FLUOR. FIXTURE3 3 WAY SWITCH EXIST. EXIST. AFCI A � $4 4 WAY SWITCH FIRE PLACE LIVING ROOM C-25 �Q DQ EXHAUST FAN w/LIGHT $ DIMMER SWITCH 74 D° EXIST. EXIST. EXHAUST FAN FAN PUSHBUTTON GARAGE BEDROOM #2 OD L= DISCONNECT SWITCH O CEILING FAN O JUNCTION BOX O O TV TV JACK H- O COMPUTER OUTLET STEP CEILING FAN w/LIGHT DATA (W/ GENERAL USE DUPLEX RECEPTICLE) EXIST. O O ® PHONE JACK - PREWIRE ONLY S H-24 DATE: 02/25/2013 ELECTRIC CO. METER ® ELECTRICAL EQUIP.PANEL E.M. SCALE: 1/4" =1'-0" EXIST. �"� DES GNER PROJECT MANAGER A. BOUCARD PORCH OSD SMOKE DETECTOR THREE WAY SWITCH APPROVED BY ARSHAD VIQAR SWITCHING ARRANGEMENTS PROJECT N0. 2006-11 SINGLE POLE SWITCH CKECKED BY: AL DOUBLE POLE SWITCH r SHEET NO. A-3 ELECTRICAL PLAN ENGINEER OF RECORD SCALE: 1l4" = 1' ARSHAD VIQAR FL. LICENSE # 38863 l"} 1175 N.E. 125TH STREET SUITE 610 TEL.: (786) 663-9439 1Of100Nd 1VN01.1` ono3 )iS3001f1V NV A8 03on(IONd oC n i -c i n710710- I 7nH.J _1:3nn1Ai nnnn— nnu i Incninn-I N1 :3- - REVISION i PAN DRAIN TERMINATION NO, DATE DESCRIPTION PLUMBING NOTES PLUMBING NOTES .48 PER MIAMI DADE ORD. SEC.8-31 BRANCH FIXTURE SIZES FDCR 2903.2 THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER DOUBLE SINK 1/2" 1) ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE W/ THE LATEST EDITION OF THE Far, 1. PLUMBING CONTRACTOR SHALL VERIFY SERVICES AND PLJMBING FIXTURES SHALL MEET THE LOCAL WATER FLOW RESTRICTIONS A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR DRAIN 1/2 LOCAL OIRDINANCES AND IN COMPLIANCE W/ THE FLORIDA ENERGY EFFICIENCY CODE FOR BLDG, CONSTRUCT:0N SEWER TAP LOCATION PRIOR TO CONSTRUCTION A@PTED BY MIAMI-DADE WATER AND SEWER OR EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE SHOWER,TUB 1/2„ 2. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS NOT LESS THAN 6 INCHES(152mm)AND NOT MORE THAN WASHER 1/2" 2) CONTRACTOR TO VERIFY AT SITE LOCATION, ELEVATION AND SIZE OF At. EX.iST'ING 49A1N, 's�'ATER AND SF.:4 E:R FOR OR VALLEYS. 24 INCHES(610mm)ABOVE THE ADJACENT GROUND SURFACE. 1/2 CONNECTION OF NEW SERVICE BEFORE INSTALLATION OF ANY PIPING OR SEPTIC TANK. 3. SIZE&LOCATION OF CLEAN OUTS SHALL BE IN PLUMBING FIXTURE MAX. FLOW RATE PER FBC PLUMB.504.7.2 CONFORMANCE W/CODE OR FIXTURE FITTING OR QUANTITY 3) UNDERGROUND METAL PIPING SHALL BE PROTECTED W/ A COAT OF BITUMINOUS COMPOUND BEFORE COVERING 4• A MEANS OF CONTROLLING INCREASED PREASURE CAUSED BITUMMAST?C UR EQUAL. BY THERMAL EXPANSION SHALL BE PROVIDED WHERE WA1•ER CLOSET 1.28 9pm REQUIRED IN ACCORDANCE WITH F.B.C.SP607.3.1 &SP607.3.2 4) PROVIDE SHUT--OFF AND VACUUM BREAKER TO ALL HOSE BOBS AND FAUCETS W/ HOSE-END CONNECTION. 5• ALL TUB/SHWR VALVES SHALL BE ANTI SCALD LAVATORY(PRIVATE) 1.5 9pm WITH INEGRAL STOPS ` SHALL 6. THE FLOORS&BASE MATERIALS OF BATHROOMS& 1.5 gpm E. ALL HORIZONTAL SANITARY PIPING 3" and larger shall slope 5% AL.W FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER W/ A!R CHAMBER OR SHUCK A13SOR✓vE-RS POWDER ROOMS SHALL BE IMPERVIOUS MATERIAL SHOWER HEADS at 118 inch per foot minimum, unless noted otherwise. I AS INDICATED ON PLAN 7. PROVIDE BACK FLOW PREVENTION DEVICE AS DESCRIBED IN F.B.C.TABLE P608.1 SINK FAUCETS 1.5 9pm per foot minimum, unless noted otherwise. All piping 2'"and Q 6) VENT LINES 1-0 EXTEND 9" MIN. ABOVE ROOF AND FLASH `N/ LEAD OR CONNECT TO EXISTING VENT SYSTEM 8. WATER-HAMMER ARRESTORS SHALL BE REQ'D FOR QUICK smaller shall slope at 1/4"inch per foot minimum. CLOSING VALVES AS PER F.B.C. P-604.9 71 PROVIDE CONTROL VALVE TO ALL MAIN ENTERING THE BUILDING RISER, BRANCHES, GROUP OF FIXTURE, AND 9• THE WATER HEATER RELIEF VALVE DISCHARGE PIPING TO EACH PIECE OF EQUIPMENT MUST CONFORM TO F.B.C. P-504.7.1 10. ALL DISHWASHER DRAINS SHALL BE CONNECTED TO DISPOSALS 8) PLUMBING FIXTURE SHALL BE (AMERICAN STANDARD) OR APPROVE EQUAL, ALL FIXTURE TRIM SHALL BE AS PER F.B.C.9-409.3.1 C'I!RC'p,E PLACED, FIXTURE SHALL BE :'I�OVIDED ``:V/ SUPPORT HANGERS, ETC. 11. ALL WATER PIPING SHALL BE INSTALLED W/ACCORDANCE WITH F.B.C. P-TABLE 603.1 &TABLE 604.5 PLUMBING FIXTURES NOTES GENERAL CONTRACTOR NOTES WASTE LINES TO SLOPE MIN, 114" PER FT. UNLESS OTHERWISE NOTED. 12. WHEN REVENTING,ALL VENT CONNECTIONS MUST BE A MINIMUM OF 6" ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST FIXTURE AS PER F.B.C. P 905.5 THESE DRAWINGS AND SPECIFICATIONS ARE PART OF THE CONTRACT DOCUMENT, PLEASE 1. BATH TUB AND SHOWERS GLASS ENCLOSURES,IF APPLICABLE, VERIFY ALL THE DETAILS WRITTEN ON EACH SHEET. 10) PROVIDE FULLY ACCESSIBLE CL.EANOUTS ON SANITARY AND ANY 'A''ASTE PIPING, AT EVERY CHANGE OF DIRECTIONS, ARE TO BE OF TEMPERED GLASS. FAILURE BY THE GENERAL CONTRACTOR AND AT BOTTOM OF STACKS, CLEAN OUTS LOCATIONS AND S`:.<:F_5 ON HORIZONTAL LINES SHALL BE ACCORDING TO CODES 2. BATHROOM FINISHED FLOORS TO BE IMPERVIOUS MATERIAL, TO FOLLOW THE DRAWING PLANS AND ITS SPECIFICATIONS SHALL NOT BE CAUSE FOR AND OF CERAMIC TILE. ADDITIONAL WORK BY THE ENGINEER. ' ') FEED ALL PLUMBING FIXTURES W1 TYPE "'M" COPPER ABOVE GROUNG AND TYPE ,.L„ COPPER BELOW GROUND• COORDINATION OF THE WORK, AND 3. ALL PLUMBING FIXTURES TO COMPLY WITH FBC. OF THE SUBCONTRACTORS IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, 12) ALL SANITARY WASTE TO BE PVC SCHEDULE 40. 4. SHOWER HEAD TO HAVE ANTISCALD VALVE. '1 3) CLEANOUTS SHALL BE PROVIDED AT THE BASF. OF ALL STACKS AND ALL BLDG, DRAIN OUTSIDE THE BUILDING WA:IJ... FIN ROOF FIXTURE FIXTURE MIN.SIZE FIXTURE FIXTURE MIN.SIZE WATER HAMMER !1 4) NO SOLDERING JOINTS BELOW THE SL,� TYPE UNIT VALUE OF TRAP TYPE UNIT VALUE OF TRAP . JOB NUMBER AR- 2006- 01 R >' Fl C BATH TUB 1 THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM SHALL BE 15) ANTI SCALD PREVENTATI' E VALVES REC�UI .�D FUi? ALL SHOWERS AS FLR r:L [ ] 2 1 1l2 WASHER [1] 2 2" CONTROLLED TO REDUCE THE POSSIBILITY OF WATER HAMMER. A WATER Cd 48 HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK CLOSING-VALVE ARE bef-y&g 16) 'WATER HEATER AS PER FBC WATER CLOSET[2 8 3' KITCHEN [1] 2 2" UTILIZED, UNLESS OTHERWISE APPROVED. THE ARRESTOR SHALL BE LOCATED WITHIN AN EFFECTIVE RANGE OF THE QUICK CLOSING-VALVE. WATER It's the Law', 1 7) Z„ MIN. DRAIN UNDER SLAB AT Pv11P€. 1!4" DROP. 2 2" 2 1 1l2" HAMMER ARRESTOR SHALL CONFORM TO ASSE 1010. ACCESS SHALL BE � 4� LAVATORY [2] DISHWASHER [1] PROVIDED TO WATER HAMMER ARRESTOR Sunshine State One Call Of Fi ida, Inc. 18) ALL FLOOR ;RAIN SHALL HAVE TRAP PRIMER TO PROTECT THE SEAL OF THE TRAP, T2 2" WASH SINK (0) 1 1/2" AS PER FBC 2010 EDITION FIN DRYWALL CEILING _ SHOWER [1] 0 19) PROVIDE 1" RESEAL LIME FROM WATER SUPPLY TO EACH FLOOR DRAIN. 20) ALL PLUMBING PENETRATIONS IN FIRE RESISTANT RETED 'INALLS, PARTITIONS, FLOORS AND CEILINGS SHALL BE TUB GLASS FIRE STOPPED IN,1 APPROVED FIRE STOP FOAM. ,i z TOTAL = 16 FU'S CBS WALL Q z BEYOND LAV. I M I U ~ F- X A Q 1 5" 30" 30" 15" O O 0 d TIL .FLOOR OC EXIST. TUB ® v J COVERED W z PORCH Q uR R /C w/c co Cf 0 FROM Q D Q EXIST. U Z SEWER N D V LINE C w 116 LAV. -� U Y EXIST. 3SH-24 STEP • e • I m W I i O 0 W LV STEP e v ° o Z m 0 C0 x o EXIST. �4"C-O. (, z 0 wN 2-2 X2- i EXIST. J Z a WINDO SH-24 L Z STEP W �- N NEW 36" DOOR r ♦♦ e J O m N 9 ::u : EXIST. 30�� O r z I_j_ _ ♦ BEDROOM #1 ° EXIST. ,``,.. . a v v w DINING ROOM ` �^ L= '`''` ! BATH ; ALL EXIST Pvc's EXIST. (.j,J Z - �., EXIST, € : 4FU TO REMAIN, OFFICE O ® / , VENT , „ ,,..: •u. REMOVED AND W/C WIC W/ ZLWC U n IST. REPLACED PLUMBIN r,LU man Q. SEW R LINE a FIXTURES ONLY U U �.... .... Z Z NEW 36" D00 e ° ¢ O „� 0 EXIST. EXIST. �1FU EXIST. EXIST. m 00 � FAMILY ROOM NEW HALF WAU KITCHEN 1 �..SO ."'���"' d1�l�titJ�...°� �����SEWERLINE"'•.� N ? J � o N U , , a -� U cn Q `� L� 2FU == O TUB ® O MT i V Z LL so i® „n EXIST. EXIST. EXIST. r - EXIST. 1FU VENT - - CLO. CLO. Fu BATH 2 4F I .1 FIXTURE CLEARANCES EXIST. 2'-2"X2--2" SCALE: 1/2"=1'-0" PER FBC FIGURE 405.3.1 WINDOW s o :n m EXIST. N Q D FIRIE PLACE LIVING ROOM A 30" 5" 30" 7 p° EXIST. EXIST. GARAGE BEDROOM #2 � C O STEP - - - - z EXIST. SH-24 DATE: 02/25/2013 SCALE: 1/4" =1'-0" EXIST. DESIGNER/PROJECT MANAGER A. BOUCARD PORCH APPROVED BY ARSHAD VI AR T�0 tAr� PROJECT NO. 2006-11 P CKECKED BY: AL FIXTURE CLEARANCES - .�3 SHEET NO. A_4 SCALE: N.T.S. PLUMBING PLAN ENGINEER OF RECORD SCALE: 1/4" = 1' ARSHAD VIQAR FL. LICENSE # 38863 1175 N.E. 125TH STREET SUITE 610 TEL.: 786 663-9439 ionGONd 1VN0ileana3 34S3aoind NV As aganGONd - aCY%i -0 1 07107tC- I :3nNa -i-inniA1 nAAn vvi nnu i-incmr)­-ln1-:3- - 1 Y V 4 �t Palm MIAMI SHOR S�'VI1!AGE Sam -.f-F'R0VED BY DA1E i i STRUCTURAL ELECTRICAL i Pn �HAN,ICAL. f i i 3L!:G. 3 J SUBJECT TO COMPLIANCE WITH 11L t " ..L STATE AND COUNTY RULES AND REVISION I} r....... - S C P , --�-- .__t3 '_-VO tK NO DATE DESCRIPTION .•'f.' ". .'1.- 1. .S 5' 1.� . .. 1 11-26-2013 REVISION FOR REVISION FOR 3 NEW „ " �. I- .1 I_• .U. a.1 .1 . a. . 1.. Li.f .1 - '. L. _ .. - _.. .. .... ... . . ....... . .. - yy l ) NEW DOORS ..` raP;,)r- TI i:: i-i ^M DOORS ONLY ...................................................................I ZONE � 1 NINF)' PRE: ..S(,;�`!.(.� 1� 11-26-2013 i r".r I P(j,".3 ::3.52 �L i EXIST.SH_24__ I DEC NE G. 331_. 'L �O BE REMOVED AND I REPLACED BY 36•FRENCH DOOR EW By:—a- 0 2'-2­X2'-2" 0 _ .................... ... ...... 26 TO, REMAiN "R .. . L_._...] REVISED iMPAGK 11--26-2013 _.�. .......--------------- .---- _ _.- .----- -.--_.... --...-....._.._-- ---- ..............................................................._.....,,.,- -••------,-. _.._..,-..........-........ i r.-.••.-•.. ..................._....................................... ".-. 1 .._.........«..«.»..........»..............».»..»...».«..._.... I P A JA B A \ II^^ L ELEVAT10--11 ' EXIST. EXIST. (z"`j(,)UT'rA) T , G>NERAL CONTRACTOR NOTE i SCALE: 114" � 1' THESE DRAWINGS AND SPECIFICATIONS -2 SCALE: 1/4" _ 1' w �� � ARE AALLGTTHE DETAILLS WRITTEN DOCUMENT, :. AIu E A I __ .. _ . FAILURE BY THE GENERAL CONTRACTOR LEVEL 2 Asti ER O� � INCLUDE � E RE(-','ON FIG URATIC F SPACE C:�E z T €,. I f„ I� �" � � r . .. f ,� T"O FOLLOW THE DRAWING PLANS AND v; ITS SPECIFICATIONS SE-IALL NOT BE CAUSE FOR °-•., "`I., �"'" €'; I_ 4 DOOR ADDITIONAL WORK BY THE ENGINEER, 4 @ @� ADDITION. C�€' �M L 13':��I "I A.6 I� �> O f M � ,d�.,,� R �„ R WINDOW. COORDINATION AL W K THE WORK. AND _. OF TT-IE SUBCONTRACTORS IS THE RESPONSIBILITY w T )E-'0> 1 1 '";:.r^?": I 1 I�E C �I�`'•�I"., I���.,-�RATION O4� EXTENSION O("' ANY SYSTEM, T �.0 � E 4}e0 3 of ,TIE GENERAL CONTRACTOR. _ �.....w..M.... .. m.M.w. »» . OR THE INSTALLATI()N OF ANY ADDITIONAL EOUIPMENT � .. z W , } `°( f E f I JOB NUMBER AR- 2006- 01 wa I O C M G ' I.t 3, ..i � ..f ................ .......................... NEW _ .__.,,,., .,.-.. .............__.,,»-REVISED ........,.....-.__ bill y-dfg to ,N -26-2013 It's the law, K!S I 17 " .... GARAGE Sunshine State One Coll Of Fic;1'Ida, Inc. I DOOR �/ %� i,(=1':ND I:>R'lS`�i_;f<E.i REVISED DOORS SCHEDULE r-0 31:,, -- - - -- :.,,.........11:.x..--<:.. t' 7 ) I.MPACK /r / NEG. : -33.52 _. _ � - i 1"-26-2013 „•t 1 I'INI: rI L.0t_id �tdlND LOAD E, E ----------------------------- ------ -- - _- -----__- -______--------------- -- _.....»...._._._......,.M......-„..,,_.,�__..._.- FRAME AREA -- (ONE STORY FLDG, --- E O�.I��: - 6” - - TYIaF� (SO.FT.} OIJANT. Z4 P- Z5 P-(Z P+ REMARKS - i i s ( } ( } E"XIST 3'_-H`2 OOR is STEEL/ TO RE.-MAIN, R: 3'-0"x 6'-8" 4-3/4 20.0 OPAQUE 3 -33.52 33.52 NEW IMPACK DOOR ()to ts> 1G;3` - EXIST. (WEST) ELE-VATRO.) CAT 11 .............. .. .... ................ .... SCALE. 114" 1' T.. - / ------- 04"-30-2013 EXIST. " t - REVISED COVERED SCALE: 1,4 1 ""- PROVIDE (1) #5 BAR SUCH PORCH BAR SHALL BE EXTENDED 6" INTO EXISTING FOOTING AND TIE BEAM AND HOLE TO BE _.-_.. FILLED W/EPDXY ALL SP iGES ..- - S/ b I --_.__.. EXIST. 3SH-2 STEP ... EXIST. ROOF _-T »:T^- TRUSS ASSEMBLY BY TRUSS MANUF. __.... STEP r- SEE WALL SECTION /� FOR DETAIL 0 EXIST N`S i x ' � 2' 2"X2'- EXIST CEILING INSULATION _r 1 _ uN - - -- WINOO'�' SH-24 STEP N I EXIST.SH24 . EXIST, 32" I TO BE REMOVED AND '�q OPENING TO � REPLACED BY 36, �J REi 4MN I OPAQUE/STEEL DOOR(SEE NO A) I I O �/'� U3 I /� 10-02-2013 I _..._.._».. --- .................. ..... I V) _...... F.... (3 G 1� 11-26-2013 NEW CABINETS r'� I � EXIST. .._._. , EXIST. ''I ' �C, `�EXIST OFFICE � W .-. i:::i::iiiiii:�:::::::.P. :::::�:::::-:::::::_::_:::::::_::_::_-"::EE:E-�:ES:::„::?E„�W:::E:•:EEi:iE—::=--EE=:.�E ..:::v.:::::::..:: O :y-,.::....' BATH DINING ROOM I.. _......._. - _.... _.».-._»...... U EXIST. j......., 1/2” GYP. BIRD OVER 3/4" HIGH HAT -- FEU- WITH CONCRETE EXIST. 4'-.fit.".._TA1T � KITCIIEN iC� � z � EXIST. FURRING CEILING ASSEMBLY (�O)P� o - NEW i0 ''CAI. I � gE I � NEW 38" DOOR � 1 � ��'.��OOM � T� �n n z FAMILY ROOM i � x -- ..,f \ i I • •♦ F�Xt�Tif`.tG jIE Es£F�M •"♦ FILL CELL WHERE#4 PINS y • + i. :(: • Ya r LO.CAIED WITH CONIC. LLJ .-.-_ "j .• .i :�, � 000 Psi ,� E E I i I r pppjj E r ^ ; ..... ................................ A.....1.... ±' pq tt LL EXISTING 36 g' I 1 ----------------------- ..._.. - ------- -----------------------------.... EXIST. �Yc' EXI TO 11 CJ G, OUR I'O BE — ti ....0._p._.__...-.--_ 11 I3A'III j I 1 REMOVED AND ,° jral WALL .e f y. REPLACED BY 2 5/8 TYPE "X" GYPSUM ------ --u ONE DYER OF ~`` '+, ''� 9, WALLBOARD EACH SIDE, THESE LAYERS _. - z, vALL - NEW 36 EXIST. X 4 HORIZONTALLY F. _. .......... OPAQUE/STEEL ST' APPLIED VERTICALLY 0, , . LIVING R001�i '� - - ,- 2' 2 2 2' AND NAILED W/ BD COOLER NAILS 1 TO 9 NEW 1 WINDOW 0.C. - - I. k;t. DOOR (SEE NOA) --` I so 1 Co m , �,..s,, 36" I I x 8 -3 MIN. 3 I I vn FILL CELL WHERE q4 PINS } ^ •,;;,. Exlsrwc SUCH BAR SHALL BE IEXiST, I TEDWITHCONC. K ALL I All-26-2013 FI E PLAC' 7 , v DOOR N ARE LOCATED ..;�•�y W I a' 'I oo i _ f.«���.' r: ,.:•. EXTENDED 8' INTO IF IRE' � at ; I --- - - 's:`•';';' s,,,,.; ------ EXISTING FOOTING y i EXISTING 36 ;F 4- Ty' x AND TIE BEAM AND _ `•" ..' 1",,,,,,..... I I I ; ;,FS`': HOLE TO BE FILLED �. n i _--._ W EPDXY ALL DOOR IO I3E EXIST. '�� , EXIST. ts}� I N� `r . T. � SPLICES TO BE 30' BEDROOM 1 �i f ' 14'-0" 5TI - fr r 2°x4' WOOD STUDS C� 16' O.C. LL' REMOVED AND i �'" .... :..` GARAGE TALL I. h - - REPLACED BY - --- - z 3 NEW 36" -- OPAQUE/STEEL PROVIDE (1) �9 BAR p J................ p� � SUCH BAR SWdI` DOOR + ,�, �(S E E N OA) EXTENDED 8' INTO �, •?`' �'' EXISTING FOOTING .--°.---------------=�-:%' :�:%? I AND TIE BEAM AND i • HOLE TO BE FILLED 1 11-26-2013 �' W/EPDXY All " X,•' 1 SPLICES TO BE 30' ___-.------ .. _._---_..r}',>r. e.-'•. .......... _� 2„X4" BOTTOM _- f STEP :: :::::::::::.; 4AWOOD BASE i - --- n a r• C� I I PLATE - - E I .• EAACH SIDE E EXIST. 1/2" SIAB LINE :• :t' sIAB u __ I NAILING ® 24" O.C. --- <,.•<ExISTaN s Y-' SPI24 SONG. SLAB EXISTING -- ,. •. :.. -- E I SEE 'NALL SECTION I ,• '•'':s DATE: 02/25/2013 — - EXIST - -__... - ------___ :. .+ •'•- I I �,,,,.+✓' "wM"",•,. - y ...,.•• ��'• • •.S•• �:l •.,,•, i '•�''' ; SCALE: 1/4" �11-051 lST ' DES ���•: •ZINC , FOUNDATION .. . .. .......... _-_-__----- PORCH -�-�. j c _ 3 APPROVED --) I (—-) I —) I I--�- 1 ( 1-- —) 11-�--1 11- - 1 I I l 'l -l ..I j . ':.)•-•i -'-.)..., . ..} .,.. ' .) .I - '.. j-. ..; . PROJECT' NO. 2006-11 LEGEND (MATERIALS INDICATION) _ CICECKED BY: AL _..:....,I - III_,-'. I I I --;III,---,-,III. -=1 I I____ I I7 7 OPENING DETAIL PROPOSED FLOOR PLAN __...__ -.. _ _-,. _,..- _ .,..,- SY II30L T3ESCRIPTION WELL COMPACTED FILL SHEET NO. A®`2 SCALE: 1/4" = 1' , 04-30-20+3 �»T-T� r�EW 4°' HALF WALL ENGINEER TTA••��TTp�7 p^p.� RECORD ------ 1(}••...{�2••-2t313 � REVISED v r. � 04-30-2013 l.:E��i�d.J�lY Q� �� NEW CA.BLNETS EXIST, 4 PARTITIONS PALL ........ REVISED � NONE—BEARING (TYPICAL) WALL DETAILS REVISED EXIST, BEARING WALL ARSHAD VIQAR --• FL. LICENSE .# 38663 C, 77;r 11"75 N.E. 125Th STREET SUITE 610 -- - - — TEL.: (786) 063-9430