MC-12-13-2752_Plans co m T_ M J O F--i LL �. �j ch w E � 00 0 Z c0 0o co _ 0 Q w �. .................. ... ... ... ... a. U a W o Ln rO Ln Ln Q0 N QzU) CO � 2»GOOSENECK CONDENSATE DRAIN TO U rn X ; ; TERMINATE 7" ABOVE PERVIOUS GROUND :,; ; AT 12" MIN. FROM EXTERIOR WALL AS q 11 PER F.B.0 R-320.7. dNQISS�/ll-4,0 � • V ••• / 2"CD UNDERG. ® l '/FT a Z . \�• .................................................................................. _._...... _...._...........: _. ......................_.....-.. • , _... . M 1°CD INSIDE PARTITION ..... 1 ' � • l ' E ....... •• ........................ a .� ® Y SLOP •••..�..•• `fie _........._.. A L E �s BC-M 402.31 VENTILATION NATURAL VE 1 ox10 F z No. bib ,t gWOCFM (WINDOW OPENING > 3FT �..fM } A 14x10 Y 2M v Lli 80 10x10 REFRIGERANT LINES F ROM AHU 1 RUNNING IN EXISTING RE-CIRCULATING A ATTIC. SUCTION LINE INSULAT10N THERMAL KITCHEN HOOD TO REMAIN 1 AHU 1 RESISTANCE VALUE OF AT LEAST R-4 AND EXTERNAL PERMEANCE NO EXCEEDING 0.05 PERM. '14x12 X ;14x12 \\ ov NATURAL VENTILATION PER ui ................< .............................':.............. — ....... .. ......._._.: ,.............._...,.,.-...............-. ;...__._._..._,.....-.-..-......,_._,.,..........-...._,.. .............._....-,_,_...................-......; FBC-M 402 31 EXCEPTI N z 1 I ......... (WINDOW OPENING > 3FT _ ...:.:....:...:: 0 R/A U C T 16x10; WI w R 20x2O - A 1 80 CFM PROGRAMMABLE N EXISTING DRYER EXHAUST THERMOSTAT - 1 TO REMAIN. (2)� 16x10 CU X; 1 1»U`C I _.... ........... 0 ............ ................... C 6` , C , ! oo d'$ SN', „ „ w NO MECHANICAL WORK IN THIS AREA 0 f I A 1410 14x10 240 CFM 2M ...... j ,.:: .._, . , I :.xs... Ir U <.; .-._--_....................... O ......... z (n , o O U L- J n Z_ Q cc N Proposed Mechanical Plan SCALE: 1/4" = 1 '-0" 00 m T M w lJ wzu; two >- 0 _ c/) c/) U) U w a Q � wXM z ° ww z T M 1- U w O DATE: 12. 06. 2013 DRAWN: A.H. REVISED A.H. Sheet M- 1 . 0 AC SPLIT SYSTEMS SCHEDULE MECHANICAL LEGEND ° H . V. A. C. GENERAL NOTES: c AREA SERVED AC-1 SYMBOL DESCRIPTION c o - c SEER / EER 15.5 -' 11 N �' 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FBC 2010. THE WORK zo REFRIGERANT TYPE/ LBS. R-410 ® SUPPLY AIR. W E o THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF v s UNIT TAG AHU-1 W Lo o z ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES INSPECTIONS, TESTS, w ¢ RETURN AIR CEILING GRILLE Z INSURANCE, ETC. REQUIRED FOR THE COMPLETION OF THE AIR w UNIT TYPE VERTICAL CONDITIONING SYSTEM SHOWN ON THE DRAWINGS AND/ OR LISTED BELOW. N MANUFACTURER RHEEM = r- EXHAUST AIR CEILING GRILLE Q a 2. CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH ALL MODEL RHLL-HM4821JA n LL CONDITIONS AND SCOPE OF WORK. CONTRACTOR SHALL SUBMIT ANY COIL TYPE DX a SIDE WALL GRILLE, LOUVER w o DISCREPANCIES TO ARCHITECT-ENGINEER FIFTEEN (15) DAYS PRIOR TO c SUPPLY AIR FLOW (CFM) 1400 �_ FIRE DAMPER Lo N BIDS. ° OUTSIDE AIR FLOW (CFM) BACKDRAFT DAMPER 3. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, o0 TOTAL COOLING CAPACITY (MBH 41.0 o DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH u SENSIBLE COOLING CAPACITY (MBH) 30.1 MOTORIZED VOLUME CONTROL DAMPER. Q z ~ THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE Q ENT. AIR TEMP. (DB/WB) F 80/67 �" Q co AREH""INSIDE" DIIMENS AND ONS. M VERIFY EXACT DLOCATION OF DUCT WITH OWN w LEAV. AIR TEMP. (DB/WB) (�F) 60.1/57.8 VD MANUAL VOLUME CONTROL DAMPER 'x U RESPECT TO STRUCTURE BEFORE FABRICATION. EXTERNAL STATIC PRESSURE(E.S.P) (IN) 0.2 TO THERMOSTAT/TEMP. SENSOR 4• FLEXIBLE DUCT SHALL BE STELL HELIX WIRE ON 7/8 INCH CENTERS, a HEATER TYPE ELECTRIC O HUMIDISTAT ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR HEATER CAPACITY (KW) 4.8 WELDING TO FORM AN AIR TIGHT INNER CORE. THE CORE IS TO BE t: HEATING BTUH 17,974 CO CO2 SENSOR ���� .. ''�0 INSULATED WITH FIBERGLASS INSULATION (R-6), AND SHEATED IN A : = STAGE '�.' �\ ��'. REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET. FAN MOTOR HP FLA 3 4 3.8 sD DUCT SMOKE DETECTOR =m i PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE Z ;¢ / / / m DUCT CONNECTS TO RIGID DUCTWORK. PROVIDE STAN-OFF QUADRANT TO o o MIN. CIR. AMPACITY 32 No NORMALLY OPEN v� EXTEND DAMORE ACTUATOR HANDLE OUTSIDE INSULATION. Q _� MAX. FUSE SIZE 35 NC NORMALLY CLOSED ' '�- _ � ELECTRICAL SERVICE (VOLT/PH/HZ) 208-230/l/60 Ate •� P�E���� 5. AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1-1/2" a w A NECK SIZE AIR DISTRIBUTION DEVICE TAG (R=6 MIN.) FIBERGLASS U.L. 181 LISTED, CLASS I AIR DUCT. 0-h FM SHALL BE FABRICATED IN ACCORDANCE WITH S.M.A.C.N.A. Q SHIPPING WEIGHT (LBS) 166 0 STANDARDS. (R-6 TOP LEVEL, R-4.2 IN OTHER LEVELS). z Q DIMENSION (LxWxH) (IN) 22 X 21 X 50Y2 NOTE: NOT ALL SYMBOLS MAY APPLY TO THESE PLAN. Y 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID ° TOTAL AMPS (AMPS) -- INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT SEER / EER 15.5 U ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. WORK ¢ UNIT TAG CU-1 SHALL ALSO BE COORDINATED WITH STRUCTURE AND AVAIALBE SPACE TO ~ ENSURE PROPER CLEARANCES ARE BEIMG PROVIDED. ANY DISCREPANCIES o UNIT TYPE AIR COOLED HVAC DESIGN REQUIRES: YES NO SHALL BE REPORTED TO TEH ARCHOTECT/ENGNIEER IMMEDIATELY. o MODEL 14AJM42A u MANUFACTURER RHEEM DUCT SMOKE DETECTOR X ° 7. SUBMIT SHOP DRAWING OF ALL MATERIALS AND EQUIPMENT FOR o O APPROVAL PRIOR TO FABRICATION. o NOMINAL TONNAGE (TONS) 3.5 FIRE DAMPER(S) X w Z 0 ENT. AIR TEMP. F 95 � 8. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND D SMOKE DAMPER(S) X z LIMITATIONS OF SPACE AVAILABLE FOR INSTALLATION OF THE U COMPRESSOR QTY TYPE 1 - SCROLL EQUIPMENT AND MATERIALS UNDER CONTRACT AND PROVIDE READY Z ¢ COMPRESSOR LRA RLA FIRE RATED ENCLOSURE X / AMPS 112/17.9 ACCESSIBILITY TO DAMPERS, VALVES AND OTHER APPARATUS, W CONDENSER FAN FLA 2.8 FIRE ATE FLOOR___ X ui INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR ° CEILING ASSEMBLY MAINTENANCE AND OPERATIONS. zo MIN. CIR. AMPACITY 26 FIRE STOPPING X U MAX. FUSE SIZE 40 9. CUT ALL OPENINGS AND CHASES REQUIRED TO ACCOMMODATE THE WORK ELECTRICAL SERVICE (VOLT/PH/HZ) 208-230/1/60 SMOKE CONTROL X UNDER THIS DIVISION, AND REPAIR ALL FLOORS, WALLS, ETC., SHIPPING WEIGHT LBS 205 DAMAGED BY SUCH CUTTINGS. ALL WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH AND QUALITY OF a DIMENSION (LxWxH) (IN) 31% X 315/8 X 273/6 MATERIALS AND WORKMANSHIP SPECIFIED UNDER APPROPRIATE SECTIONS ° REFRIGERANT LINES /LS/LL (IN) 7/8" / 3/8" FOR THE BUILDING. z PROVIDE 1" UNDERCUT AT ALL DOORS WHERE � RETURNS TRANSFER DUCTS ARE SHOWNINCLUDING 10. AIR CONDITIONING SYSTEM CONTROLS SHALL CONSIST PROGRAMMABLE BATHROOMS a THERMOSTAT FOR HEATING AND COOLING STAGES AS REQUIRED FOR NOTES AND ACCESSORIES: o EQUIPMENT. THERMOSTATS SHALL BE WALL MOUNTED UNLESS INDICATED 360 270 1. UNITS RATED IN ACCORDANCE WITH ARI STANDARDS 210/240 OR . AIR RETURN SHALL COMPLY WITH F.M.C. 601.4 OTHERWISE. / / BALANCE RETURN AIR REQUIREMENT 2. PROVIDE 1 YEAR MANUFACTURER WARRANTY (PARTS AND LABOR) AND EXTENDED 11. ALL EQUIPMENT SHALL BE PROVIDED WITH VIBRATION ISOLATION IN 5 YEARS COMPRESSOR WARRANTY PARTS ONLY. PROVIDE ANTI-THEFT ANCHORING DEVICE FOR THE ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS TO 3. PROVIDE COMPRESSOR WITH CRANKCASE HEATER. CONDENSING UNIT AS REQUIRED BY DADE COUNTY REDUCE/ELIMINATE NOISE AND VIBRATION FROM TRANSFERRING TO THE 4. PROVIDE SECONDARY CONDENSATE DRAIN PAN. ORDINANCE OCCUPIED SPACE. 5. PROVIDE WEATHERPROOF ELECTRIC CONTROL AND SINGLE SIDE SERVICE ACCESS. 12, IN COMPLIANCE WITH THE FLORIDA BUILDING CODE MECHANICAL 307.2.3, 6. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT,48" ABOVE UNIT AND 4" ON SIDES. PROVIDE, INSTALL AND CONNECT AN APPROVED WATER LEVEL DETECTOR 7. PROVIDE SINGLE POINT POWER ENTRY FOR HEATER AND UNIT. OR FLOAT SWITCH TO CONTROL OVERFLOW BY AUTOMATICALLY SHUTTING DOWN EQUIPMENT UPON ACTIVATION OF DEVICE. 8. PROVIDE INTERNAL SPRING ISOLATION FOR SUPPLY FAN. 9. PROVIDE MOTOR OVERLOAD AND THERMAL PROTECTION. 13. REFRIGERANT PIPING SHALL BE COPPER TYPE "L" FOR AIR CONDITIONING & 10. PROVIDE THERMOSTAT CONTROL TO MATCH CAPACITY STAGES, FOR BETTER HUMIDITY REFRIGERATION (ACR). ALL ABOVE GROUND PIPING SHALL BE HARD AND TEMPERATURE CONTROL AS WELL AS MORE ENERGY EFFICIENCY SYSTEM. DRAWN WITH WROT COPPER REFRIGERATION FITTINGS. ALL LINES RUN 11. PROVIDE STARTER AND DISCONNECTS SWITCH BY ELECTRICAL DIV. 16 FOR CU. UNDERGROUND SHALL BE SOFT COPPER RUN IN PVC SLEEVES. 12. PROVIDE FACTORY MOUNTED STARTER AND DISCONNECTS SWITCH FOR AHU. 14. ALL REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH ARMAFLEX 13. PROVIDE REFRIGERANT LINES SIZE AS RECOMMENDED BY MANUFACTURER. O a- TYPE AP 3/4 INCH FOAM PLASTIC INSULATION FOR THE ENTIRE LENGTH z fn OF RUN. INSULATION SHALL BE INSTALLED WITH ARMSTRONG #520 ADHESIVE WITH 100% COVERAGE ON ALL BUTT JOINTS, INSULATION SHALL U BE SLIPPED OVER PIPING IN ONE PIECE, WITH NO LONGITUDINAL JOINTS. EXPOSED PIPING INSULATION (INTERIOR & EXTERIOR) SHALL BE FINISHED w W WITH TWO COATS OF LATEX PAINT PER MANUFACTURER'S INSTRUCTIONS. w 15. GUARANTEES: FACE SIZE o C/)A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER TAG AIR DISTRIBUTION SCHEDULE 0 2t od THIS CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM CFM z DATE OF START-UP. TAG MANUF. & MODEL FACE SIZE NECK SIZE MATERIAL FRAME FINISH DAMPER THROW NC FM RANGE NOTES a B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP A TITUS / 250-AA SEE PLAN SEE PLAN ALUM SURFACE WHITE OBD - MAX. 16 SEE PLAN CEILING DIFFUSER FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1 YEAR T FROM DATE OF ACCEPTANCE. T1TUS SEE PLAN SEE PLAN ALUM SURFACE WHITE - - MAX. 24 SEE PLAN RETURN TRANSFER R TITUS/350 FL SEE PLAN SEE PLAN ALUM SURFACE WHITE - IMAX. 24 SEE PLAN IRETURN GRILLE 16. TESTING: A. ALL REFRIGERANT HIGH SIDE PIPING TO 300 PSIG. LOW SIDE TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 28% (*) EQUIVALENT MANUFACTURER: METALAIRE, PRICE, GTI, ETC MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25 GENERAL NOTES: HOURS WITH PUMP OFF. BREAK VACUUM WITH REFRIGERANT. 1. FINAL COLOR SELECTION SUBJECT TO OWNER APPROVAL. B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET 2. FLEX DUCT SIZE TO BE SAME AS DIFFUSER NECK SIZE. co WITHIN 5% USING A.A.B.C. PROCEDURES AND TESTS. SUBMIT 3. PROVIDE SPIN-IN COLLAR WITH VOLUME DAMPER AT M AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL TRUNK TO FLEX DUCT CONNECTION. cy) INSPECTION. 4. PROVIDE TYPICAL 4-WAY DIFFUSION, 2-WAY OR 3-WAY LlJ -i LL ONLY WHERE INDICATED ON PLANS. U 17. MATERIALS WITHIN THE AHU CLOSET RETURN AIR PLENUM SHALL BE z w NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE uJ QC THAN 25 AND SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN O TESTED IN ACCORDANCE WITH ASTM E 84 AS PER FBC-M 602.2.1. � U W a 75 C/) C/) W X co z ° ww z T M� M U W n O IL DATE: 12. 06. 2013 DRAWN: A.H. REVISED A.H. Sheet M-2 . 0 rn cy') cy) CD —i ILL ul) r- cy) E 00 rl- L 1� cy) 00 F_ 00 r- — I SUPPLY DUCTA EQUIP. TOP 0- U- ROOF -0 - 0 c: cy) ........ ......... SEE INSERT DETA FIBROUS GLASS SUPPLY AIR DUCT c\j DISCHARGE Q U) 0 00 FLANGE 2j" SQ. WASHERS Q z co 12" MAX O.C. 22 GAUGE S.M. 16 GA. H o i I DUCT PLENUM TO BE MECHANICALLY HURRICANE MIN. 2 PER SIDE < rn STRAP 1"x3" COLLAR ATTACHED TO AHU. FBC-R 1601.6.2.2 1/4"X1 SELF DRILLING AIR HANDLING UNIT # 10x1j" SHEET WALL-—------- I I 't%lk%l COND. UNIT SHEET METAL SCREW (SEE ARCH. DWG.) WALL METAL SCREWS \4NOI (SEE ARCH. DWG.) . ..... . 3/8" X 2-1/2" AHU 41� o QUICK-BOLT EXPANSION REFRIGERANT LINES EQUIPMENT GLASS FABRIC & MASTIC C OSURE ANCHOR. (TYP OF 4 0 :kO FLANGE-, OR UL LISTED PRESSURE S NSITIVE ONE PER CORNER OF UNIT) ISOMODE PAD AUXILIARY OVERFLOW SENSOR. ALUM. TAPE (SEE EXCEPTI NS) LIO c NEOPRENE VIBRATION PAD EQUIP, TOP PERFORATED CAP 12"MIN. ABOVE BOTTOM OF DRAIN PAN 7 CONDENSATE DRAIN W/TRAP SCREW, POP RIVET OR A4 AND CLEAN-OUT \-SPOT WELDE TO EQUIP. LANGE EXISTING ANGLE 6" CONC. PA,D a d w IRON FRAME SUPPORT 1 x 1 x 1/4". EQUIPMENT ui wz FLOOR (AHU, AC, HEAT PUMP, FAN COIL) NOTE: VIBRATION PADS NOTE: PROVIDE MIN. 4" CLEARANCE ALONG THE SIDES, BACK AND TOP OF (TYP.) AIR HANDLING UNIT, WITH A TOTAL WIDTH ENCLOSING SPACE BEING MECHANICALLY ATTACH AND SEAL Cc AT LEAST 12 IN WIDER THAN AHU. AS PER FBC-R-M1305.1.1. PLENUM TO A.H.0 DUCT FLANGE AS 0 FMC-2007-603.7 AND SMACNA 0 Lu PROVIDE ACCESS FOR FILTER REPLACEMENT AT FIELD. PAGE 2.14 (FIG 2-25) 1: z O CONDENSING UNIT BOLTED TO Lu CONCRETE PAD TO WITHSTAND TYPICAL A/C MOUNTING DETAIL PLENUM ATTACHMENT TO AHQ .0 x HURRICANE FORCE WINDS. N.T.S. N.T.S. PER FEMA & FBC REQUIREMENTS PERFORATED 2 VENT CAP SHUT-OFF DEVICE /--1/4" COATED WIRE CABLE FLOAT SWITCH TO SHUT- ------ AROUND UNIT AS SHOWN DOWN EQUIPMENT (EZ-TRAP SERIES 200 OR EQUAL) Lu VC OVERFLOW DRAIN LINE L 3/4- A/C UNIT 318" EYE BOLT SLOPE 1/8"/ FT. DRAIN PAN C.D. LINE 3/4" MIN. c: 6" CONCRETE SLAB ISOMODE PAD (TYPICAL) UNION REMOVABLE CAP w n NOTE: CONDENSING UNITS TO BE INSTALLED ABOVE FLOOD LEVEL CRITERIA CONDENSING UNIT MOUNTING DETAIL COND. DRAIN TRAP AUX. OVERFLOW LINE DETAIL N.T,S N.T.S. Lu z 1 22 Ga HANGER 0 BAND CLAMP W/BAND ST .2:22 Z < NOTE: 0 1j" HANGER BAND CLAMP WITH WIRE IS OPTIONAL,. 3>1�1 1/2" MIN, 22 GAGE HANGER STRAP 2"x2" ANGLE x 4" LONG FLEX DUCT 24"0 MAX. TO BE 22 GAGE OINSTALLED FIBERGLASS DUCT NOTE: MAXIMUM DUCT SIZE IN ACCORDANCE LIMITED TO 24" FOR W/MANUFACTURE'S INSTALLATION THIS ARRANGEMENT 00 INSTRUCTION. USE DUCT SEALER co T_ & BANDING DEVICE. co co U FLEXIBLE DUCT SUPPORT FIBERGLASS DUCT HANGING DETAIL U- N.T.S. N.T.S. W Z C/i Lli w LLJ ry- 0 C/) C/) o W < < C/) w LJJ T< co z C) WW z cr) IL 0 Li O 0- DATE: 12, 06. 2013 DRAWN: A.H. REVISED A.H. Sheet M-3 . 0 � r.I { BY' r yI W i