Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-13-1583
V Inspection Worksheet ` Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-195281 Permit Number: RF-7-13-1583 Scheduled Inspection Date:August 21,2013 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: HANNAU, ROBERT Work Classification: Tile Job Address:813 NE 97 Street Miami Shores, FL Phone Number (305)759-4744 Parcel Number 1132060142590 Project: <NONE> Contractor: ENVIROTECH ROOFING&CONSTRUCTION INC Phone: (305)207-4993 Building Department Comments Infractio Passed Comments TILE RE-ROOF INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 20,2013 For Inspections please call: (305)762-4949 Page 13 of 39 SIMMS 7066 SW Street Miami,FL 33155 Tel:786-398-9179 Fax:786-800-2627 al roofinsoection(Mamail.com LAB CERTIFICATION #10-0512-01 SITE SPECIFIC INFORMATION UPLIFT TEST-TAS #106 Roofing Contractor ENVIROTECH ROOFING Permit# Job Address 813 NE 97 ST MIAMI SHORES FL Owner's Name ROBERT HANNU Type of Tile EAGLE CAPISTRANO Date Installed Approximate Roof Height 1Z_—feet Roof Pitch 3/12 Type of Access to Roof LADDER Approximate Square Footage of Roof 28 fe Required Testing Force 35 Lbs Date Tested 08120113 Number of Tests 74 Testing Equipment F.G.E.100 Contact Name DARWIN Phone# 786-317-1046 LOCATION #OF TEST PASS #OF TEST FAIL Corner 8 Tests 8 Pass Test Fail Perimeter 11 Tests 11 Pass Test Fail Field 38 Tests 38 Pass Test Fail Ridge 17 Tests 17 Pass Test Fail TOTAL 74 Tests 74 Pass 0 Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106,THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST.THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTRY,WITH NO DEVIATIONS.THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS.THIS REPORT IT IS NOT VALID FOR INSURANCE CLAIMS. T.L WA P.E. 67416 A-1 Engineering Inspection Services, Inc 7066 SW 44 Street Miami,FL 33155 Tel: 786-398-9177 Fax: 786-800-2627 alroofinspection&gmail.com LAB CERTIFICATION#10-0512.01 SKETCH OF ROOF August 20, 2013 813 NEW 97 ST MIAMI SHORES FL t t t t t t t t t t t t t t t t t t t t xt t t t t t t t t . t t t t t t t t t t t - t t i Miami Shores Village - -- Building Department JUL 15 013 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795.2204 Fax:(305)756.8972 ° INSPECTION'S PHONE NUMBER(305)762.4949 BUILDING Permit No. FBC 2%0 PERMIT APPLICATION Master Permit No.12,A 3 5b-3 Permit Type: BUILDING ROOFING JOB ADDRESS:5�NVL-- City: Miami Shores County: Miami Dade Zip: Folio/Parcel#. — Is the Building Historically Designated:Yes NO Fly Zone: OWNER:Name(Fee Simple Titleholder): Phone#: Address �� City: L ��S State: Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Address:���Z\ o City: State• Qualifier Name: Phone#.--S�?Z State Certification or Registration Certificate of Competency M Contact Phone#:���`�-`�1®l�Email Address:ftt \* DESIGNER:ArchitectlEngineer. Phone#: Vann„of Work for Ois Permfte-s,—\A tV®AN,ZA�—N SgaareMnear Footage of Work: Type of Work:,OAddition OAlteration Olaf w lace lition A v",!Tr Description of Work: Color thru tile: Submittal Fee$ ' ° Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/ Aucadon Fee$ Technology Fee$ Double Fee$ Shuctnral Review$ TOTAL FEE NOW DUE$ Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOHMS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature �or Agent Contractor The foregoing instrument was acknowledged before me this� The foregoing instrument was acknowledged before me tlti day of ,201E!�,by &NV95L � , day o .20-a�„ ho is ersonally known tot or who has produced fo is own to or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: list## ELISA I POUSO ELISA 1 POQ Sign, 2°, `�: Notary Public-State of Florida Si �Y P�ec Notary Public-St . •. .• My Comm.Expires Florida Print %^9 �:= Commission EE 207519 pmt; :� Bonded Through National Notary Assn. %,; F,o My CornmissiOn Ex My Commis Commission it EF 207539 u•` Bonded Through Natio APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 3n22012)(Revised 07/10/07)(Revised 06/1012009)(Revised 3/15/09) b I I ! 11111 � I� t1 f� 1 Ill III I h� OF COMMENCEMENT �:s1=11 7 P'������ ' OR ('�� 2w7�? F9 4�:25g (1�r) RECORDED 07/26/2013 11:08:41 A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION HARVEY RUVI N r CLERK: Of COURT MIAMI-DADE COUNTYr FLORIDA PERMIT N U TAX FOLIO NO. LAST FACIE STATE OF FLORIDA COUNTY OF MIAMI-DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. This Nodes of Commencement should be recorded at The Clerk of Courts Miami-Dade County Recorder Courthouse East,22 NW First Street let Floor,Miami,FL 33128 1. Legal description of property and streettaddress: 1 2.Description of improvement: e-ri 3.Owner(s)name and address: 9103 ba !s►�!f✓ Interest in property: A4 Name and address of fee simple titleholder: 4.Contractor's name and address: rvG"* N 2 :p�,rw.► VCF7L 5.Surety: (Payment bond required by owner from contrilME IDA,COUNTY OF°VIDE p cOUly�, HEREBY TIFY that On Is a true copy of the O� C41" OO Name and address: g - a Amount of bond$ 6. Lender's name and address: AR VD4011N.CLEO&a a nd coudy ca, 7. Persons with the state of Florida designated by r pon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and address: 8. In addition to himself, Owners designates the following person(s)to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified nC Signature of Owner Print Owner's Name J\®�VZT V Prepared by Swom to and subscribed before me this day of c- _, 201 . Notary Public Print Notary's Name My commission expires: (Seal) Notary Public-State of Florlda . •ii My Comm.Expikes Oct 4,2018 Commission 9 EE 207519 Bonded Through NatlonW Notary Assn. Jul 26 2013 10: 23AM Envirotech 7864649678 P. 1 CERTIFICATE OF LIABILITY INSURANCE Producer; Lion Insurance Company 7/12/2013 P Y This cw"Cate Is issued asa matter of intbrmatiort only end cwdfsm no ckhts 2739 U.S.Highway 19 N. upon the cervicew Holder. This eertillaaae do"twtaroerrd,=tand oralter Holiday, FL 34691 the cGV* ae afforded by the policies blow. (727)938-6562 insurers Affording Coverage =mss South East Personnel Leasing, Inc. & Subsidiarle Company NAIC d Insurer A: Lion Insurance 11075 2739 U.S. Highway 19 N. Insurers: Holiday,FL 34691 Insurer : nsruerD: nearer E: Coverages PaWCWM& maybe iia�lularmayP�tnegllKtYeQ1CA8aoroadbYe4v0YC109dasairJSdhaeefalswplsgtoe/eiet .il fB.BrdCCnd[6Ca60 suo11 Idea.A� tM0 Ipg t>D ��Q�flmlm ilpN71818Yh8f968ElIpr NR AFL eficy Effective PO E h tan Date L'M Daum type of Inswance Policy Number Date � ><P Limbs EMERAL LWUHY (MM/DD/YY) (1+tM/DD/YY) Ciowme mial General L OMMY EachOocum m C6aimaMatde 0 Oran am+aseroredeapoewaa.iE+► ooa+relra) triad� enerel aggregate BtrdtappUee Per Perean8lAdvin)my � 13 Moo r AMA Pratlleb-Comptgsaee TOItI0O LE LIABILITY Combtrea Bkgte Ltrldt Aft Atft MA A*"riq Aea,a dmft sodfr" Sdsdlid AWn (Par�d MW Ache N-Ow MdMos soft" (Pa Acldw4 ' P^srra+lyr�a iPerAcgdgnp EXCRUmMOREL.LA LIABLrry e om ■ 3 Clams Maas Ocar►ercs RAVW*dm t a na° and M 71949 0101/2013 01/01/2074 X WC Stsbt• J6,45 bbgy oificerhnan>ber to t finite ezcdtled? NO E.L.Each Ackte0000to If Yes,describe Woorepam Po�lm below. E L.Die-Ee Other .. aetae-Paaoo00 Lion Ittsurance C01"PanY Is A.N.BW*Cam a rated A- Ex�LObt. AND*12616 Die one O iLou'co'&(VGbklea/R,sckmlDMs added by Endomemet�+g Coverage onO aPPIM to MM artpbyee(s)of S"East Emplom Lc"Se ped t o the f Isiong Client ID: 3665-174 Iltc that are leased m the foRowin9"Client Camparly°: appuee to Initrcies Utatrred Sautl� Wavirotech Among a crostmcaon,rafts. Coverage does rte "b' by East Personnel Leasing,Ire.6 Subsidiades BOW OVby'(s) .while w+orktng in:FL. �M"etnpfoyee(s)or Independent contra 9)of the Client Cwnpany or any other�'. A ojec tits ee: empbyee(s)teased to the Client t;ompany can be abtaino by fafeng a request to(727)937.2139 cr by ca1bV(727)938-S%2. ISSUE 07--12-13(Mr) Q CAM MIAMI !3 VI �06 CANCELLATION now fttw OLKI)M©DEPARTMErr IaiW anaae►�xOSmall�dayswPoSnrwd�btlu fey►rmwadEslhs rhs Wkft t�OM TNDAVENUE cteaaeonorte�tlya►arordnasl.an0�eh m lbagaasa�butaarebdoasstatimppearo NBAMI SHORES.FL 33139 r I , ►� f CERTIFICATE OF LIA.B1LITY INSURANCE THIS CE:RIIFlCATE IS ISSUED AS A MATTI~R OF INFORMATION ONLY AND CONFERS NO 111313 S UPON THE GERTTFECATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATTVF.LY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.mu� errdersed P StIBROGATiON IS WAIV1rD,subJect ip IMPORTANT: If the eertlOcate holder is an ADDITIONAL M1JTRED,tlu3 ponopesl the tarns and condWoam of the Poky,certain Policies may require an endorsement A statement on this cadMeate does not confer rights to the certifkna holder in Ueu of such emlorseswI144 CO ACT AMADO�CANO PRODUCER ONE 233.683$ F No 306)233.9989 StEtevode 1ttsleance Cottsultatts stateinlCiltreusouih.rret 11364 Qt>all Roost Drive INSURERM AFFORDING COVERAGE NAIC S Miami,FL 33157 Century Surety Co Phony 305 233-MM Fax )233Sg6g INSURER A: INSUR>st INSURED ENVIROTECH ROOFING AND CONSTRUCTION INC INSURER c: INSURER D: 13721 SW 121 Terrace INSURER E: Miami,F133176 (305)207-4993 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: TFOS IS TO CERTIFY THATTHE POWCIES OF iNSUTRANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWTHSTANOWG ANY REQUIREMENT,TT:RAII OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED G MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DE scmSED HEREIN iS SUBJECT TO ALL THE TERMS, CLAIMS- EXCLUSIONS AND CONDITIONS OF SUCH{ CIE s LIMITS SHOY4�1 MAY HAVE BEEN REDUCED BY PAID POLICY W LIM�am INS TYPE OF INSURANCE POLICY NUMBER M EA OCCURRENCE S 1 O ow-00 GENERALtJAB1UTY t 1 ."' P E- TO Kerr $ 100,000.00 ® COMMERCIAL GENERAL LIABILITY IVIED E*(Any O1e PO159r, _56,000-02 ❑ ❑ S.yAUS 0 OCCUR Y COPS24076 05/0612013 05/08/2014 PE�ISONAL 8 AOV maw 1,000,000.00 A ❑ GENERAL AGGREGATE $ Z,D00, OD ❑ PRODUCTS-COMP/OP AGG $ 1,000,000.00 GE L AGGREGATE UMTr APPLIES PER: $ ❑POLICY ❑ PR ❑ LOC O SINGLELIMII as�erd $ AUTOMOBILE LIABILITY BODILY INJURY per person) $ ❑ ANY AUrO BOMLV INJURY(Par aoddeg $ SCHEDULED AUTOS NOWOVO ANN $ D ra e ❑ HIRED AUTOS ❑ AUTOS $ UMMULLA UAEI ❑OCR EACH OCCURRENCE $ ❑ AGGREGATE $ EXCESS L1A8 CLAIMSIIAADE $ DEp ON$ rl WC STATU- 0 H- woffia OOMPE MTION ER AND EEtPLOYERS'LIABILITY YIN F—L EACH ACCIDENT $ �� M iE V Q MIA E L DISEASE-EA EMPLOYS $aEMlEXC W J EL DISEASE-POUCYtJMiT $ pno I1sres,_ OF OPERATIONS below DESCRIPTION OP OPERATIONS 1 LOCATIONS!VEHICLES(AUaob ACORD 101,AddRional Remarks Schedule.If more spa¢o Is required) ROOFING-RESIDENTIAL AND COMMERCIAL CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE MIAMI SHORES VILLAGE ACCORDANCE EXPIRATION DATE THEEREOF,NOTICE BE DE?LNERBD IN ACCORDANCE WITH THE POLICY PRO BUILDING DEPARTMENT 10050 NE 2 AVE AUTHORTZEDREPRESENTATIVE MIAMI SHORES.FL 33138 ® ORD CORPORATION. AiI Tights reserved. The ACO name and logo are registered marKs of ACORD ACORD26(2010105)OF 'CERTIFICATE OF LIABILITY INSURANCE 7/12/2013 Producer: Lion Insurance Company This Certificate is Issued as a matter of information only and confers no rights 2739 U.S. Highway 19 N. upon the Certificate Holder. This Certificate does not amend,extend or alter Holiday, FL 34691 the coverage afforded by the policies below. (727)938-5562 1 Insurers Affording Coverage NAIC# Insured: South East Personnel Leasing, Inc. & Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Insurer s: Holiday, FL 34691 Insurer C: Insurer D: Insurer E: Coverages The policies ofirmsorsce listed to the Insured named above for the policy period Indicated.Notwithstanding artyreguirement.term or condition of any contract or other docurnerdwith respect to this certificate maybe issued or may pertain.tine Insurance afforded by the policies described herein is subject tool the terms,exclusions,and conditions of such policies.Aggregate limits shown may have been reduced by paid claims. MR ADDL Policy Effective Policy Expiration Date Limits LTR g,SRp Type of Insurance Policy Number Date (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence s Commercial General Liability Damage to rented premises(EA Claims Made 13 Occur once) s Mod Exp Personal Adv Injury VUT ral aggregate limit applies per. otiq ❑Pro)ea ❑ LOC General Aggregate Products-Comp/Op Ag9 MOBiL E LIABILITY Combined Single omit (EA Accident)lyAutO Bodily" Ali Owed (Per Person) Sdiodtted Auras Hied Atd08 Bodily hjuy Nw OAmsd Altos (Per Accident) Property Damage (Per Accident) EXCESSIUNBRELLA LIABILITY Each0=rf80ce Gear Claims Made Aggregate g 0 Deductible A Workers Compensation and WC 71949 01/01/2013 01/01/2014 X I WC Statu- OTH- Employers'Liability tory Limits ER Arty pmprietor/partnedexeaftive officedmember E.L.Each Accident $1,000.Oro excluded? NO E.L.Disease-Ea Employee $1,0001000 If Yes,describe under special provisions below. E.L.Disease-Policy Limits $1.000.000 Other Lion Insurance Company is A.M.Best Company rated A-(Excellent). AMB#12616 Descriptions of Opomdone/LocationsNehk les/Exclusions added by EndorsementlSpecial Provisions: Client ID: 36-65-174 Coverage only apples to active employee(s)of South East Employee Leasing Services,Inc.that are[eased to the following"Client Company": Envirotech Roofing&Construction,Inc. Coverage only apples to Iniorres Incurred by South East Personnel Leasing,Inc.&Subsidiaries active employee(s) ,while working in:Fl- Coverage does not apply to statutory employee(s)or independent contractors)of the Client Company or any other entity. A list of the active empoyee(s)leased to the Client Company can be obtained by faxing a request to{727)937-2138 or by calling(727)938-5562. Project Name: ISSUE 07-12-13 iWn Beoln Dates 6/28/2013 CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE Should arty of the above described policies be careefled before the expiration date thereof,the issdM inurervd9 endeavor to mail 30 days written notice to the certificate holder named to the led,but faikre to do so shag Impose no BUILDING DEPARTMENT obligation or GabiAty of any kind upon the insurer,its agents or representatives. 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 i a AIV CIT ` JUL 15 2013 COPY SECTION 13— A HIGH VELOCITY HURRICANE ZONES—REQU OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope.As it pertains to the section,it is the responsibility of roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of the section.The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner ant the contractor.The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics-Workmanship:the workmanship provisions of Section R4402 are for the u p rpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. 2. f v�� Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to removing the existing roof system). 3. A±—Common roofs:Common roofs are those which have no visible delineation between neighboring units(i.e.,townhouses,condominiums,etc.)In buildings with common roofs,the roofing contractor and/or owner should notify the occupants of adjacent units of roofing�Y P to be performed. 1 ng pe mred. 4. 1 ff Exposed Ceiling:Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance;therefore, roofing nail penetration of the underside of the decking may not be acceptable.This provides the option of maintaining the appearance. 5. & Ponding water:The current roof system and/or deck of the building may not drain well and may cause water to pond(accumulate)in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer.Pounding may shorten the life expectancy and performance of the new roofing system.Pounding conditions may not be evident until the original roofing system is removed.Pounding conditions should be corrected. 6. Overflow scuppers(wall outlets):It is required that rainwater flows off so that the roof is not oven ded from a buildup of water.Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402,R4403 and R4413. 7. —KLVengladon:Most roof structures should have some ability to vent natural airflow through 9 the interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be reduced.It may be beneficial to consider additional venting which can ult in extending the service life of the (Is !— Owner/Agent's Signature Date Contractor Signat Date Revised on 7/9/2009 LD MM 77 7W.77, 1117, i .. r.T".V : a = r. 1 • • •i1 • a MEN MKINNOMMELMOMMEN u ITI!!IMMEMINEEMNIMMEEMENNEEMEN ■iii=�� s��l�, ►' ��:1■■■■■■■■■■■■■ t ■ - .fir.��i Ronde Building Code Edition OM7 Form wah valoall muffumozom Uniform Permit • •• �Q ••�1r. AIA d R,O I SVIMMI Roof System Manufaclurer. Notice of Acceptance Nunnber. !�'O� .Oy Minimum Deslg n Wind Pressures,K Applicable(From RAS 127 or WcUladons): 9— P3. MWmum Design Pc S MaMod ofdie att chment• t Staep Slo ' "--s aL�Q+°rn Descriptlo�' Dock Type: q��\� ��,► Roof Slope: m"lation: 3 :12 Fire 11a or; astener Type&Spocing: �� •• ��` Ridge Ventlladon? dheshre Type yl cap Sheet: go ���j oaf covering: Moan Roof Helght:...� - Type&Sire Drip dgo: •� 123 0148 120 PAGE 4 e� Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Ille ralcuiations) For Moment-based the systems,choose either than Method or equal o the M,Compared the lees f o area of the values from Mr If the Mc values are greater the roof,than the tile attachment method is acceptable. Method 1"Moment-Based Tile Calculations Per RAS 127" P' x �l'7t. ♦ �1=Mr, a_ �5__• NOA M, ���-- ( ,• )-Mg.-1 N=M S-- NOA M, 'L4 (P2 A 4:4 2�-Mg:*-ri1�. =M,3� NOA Mr %N% FP -44' 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(M,)From Table Below NOA Mr - M,Required Moment Resistance* Mean Roof Height 15, 20' 25' 30' 4,V Roof Slope 42.2 2:12 34.4 36.5 38.2 39.7 3:12 32.2 34.4 3 .0 37.4 39.8 30.4 322 33.8 35.1 . 37.3 4:12 - 5:12 28.4 30.1 31.6 32.8 34.9 26.4 28.0 29.4 30.5 32.4 6:12 30A 7:12 24.4 25.9 27.1 28.2 *must be used in conjunction with a list of mo(nent-based the systems endorsed by the Broward County Board of Rules and Appeals. .based the s stems use Method 3.Compared the values for F'w the values le U lift Y area of the For each Uplift-based If the F'values are greater than or equal to the F,values for attachment method Is acceptable. Method 3"Uplift-Based Tile Calculations Per RAS 127" XI:I: -W:_x cos 8: NOA F, (Pz:_ XI: __,.__._..x w:_ :...._x cos B: =F,2: . = x w:= _- )-W:---x cos 9: NOA F' (Pi_ x I: _._., =F,�. Where to Obtain Information Where to find Symbol Dwription red by PE based on ASCE 7 Design RAS 127 Table 1 or by an engines anatysls preps Pressure P1 or P2 or P3 .. Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynandc Multiplier d NOA aesto"Manent due to Gravity M NOA i Attachment Resistance M NOA ,• Reo red Moment Resistance M Calculated NfUdntum Attatfiment Resfatenw P F" NOA Calculated U IUt Resistance Ave 7tie Wef t W NOA Tile Ohnensions 1=length NOA w=width Ali c obit w must be submitted to the Budding Oftidal at the time o1 permit application. KUM MIAW-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITPING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISIO Mi N mifi,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA M=.miamidade govbera Eagle Roofing Produ is LLC; 1575 East C.R.470 S mterville,FL 33585 COPE: s NOA is being issued under the applicable rules and regulations governing the use of construction materials.The cumentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to b a used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). his NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or s pend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this ceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to eet the requirements of the applicable building code. 's product is approved as described herein,and has been designed to comply with the Florida Building Code cluding the High Velocity Hurricane Zone of the Florida Building Code. ESCRIPTION: Bel Air,Bel Air Double Eagle,Ponderosa,Ponderosa Double Eagle,Golden Eagle Low Profile Concrete Tiles ABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following tement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. NEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change the applicable building code negatively affecting the performance of this product. RM[NATION of this NOA will occur after the expiration date or if there has been a revision or change in the naterials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, or sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section f this NOA shall be cause for termination and removal of NOA. VERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the xpiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and hall be available for inspection at the job site at the request of the Building Official. s revises NOA# 11-0321.02 and consists of pages 1 through 10. e submitted documentation was reviewed by Alex Tigera. NOA No.:11-0430.04 h1�MtiDADEC Expiration Date:10/05/16 Approval Date: 08/02/12 Page 1 of 10 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using"Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2.PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dim_ ensions Specifications Description Bel Air Concrete Tile L= 17" TAS 112 Flat profile concrete roof tile equipped with two W= 12 '/a" nail holes. For adhesive set,direct deck or Thickness='/z" battened nail-on applications. Bel Air Double Eagle L= 17" TAS 112 Flat profile concrete roof tile equipped with two Concrete Tile W= 12 '/a" nail holes. For adhesive set,direct deck or Thickness='/z" battened nail-on applications. Ponderosa Concrete Tile L= 17" TAS 112 Flat profile concrete roof tile with slate finish W= 12 '/a" equipped ed with two nail holes. For adhesive set, q Thickness=%2" direct deck or battened nail-on applications. " TAS 112 Flat profile concrete roof tile with shake finish Ponderosa Double Eagle L— 17 p Concrete , ete Tile W_— 12 '/a equipped with two nail holes. For adhesive set, Thickness=%2" direct deck or battened nail-on applications. _ Flat profile concrete roof tile brushed finish Golden Eagle Concrete L 17 TAS 112 p Tile W= 12'/a" equipped with two nail holes. For adhesive set, Thickness=%2" direct deck or battened nail-on applications. Trim Pieces I=varies TAS 112 Accessory trim,clay roof pieces for use at hips, w varies rakes rid g es and valley terminations. varying thickness Manufactured for each the profile. OWE CouMY NOA N ate:10/05/04 � 1 Expiration Date:10/05!16 Approval Date: 08/02/12 Page 2 of 10 2.1 EVIDENCE SuBmrMD: Test Aeencv Test Identifier Test Name/Reuort Date PRI Asphalt Technologies ERPF-001-02-01 TAS 112 Aug.2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108(Nail-On) Redland Technologies x0402 Withdrawal Resistance Testing of screw vs. Sept. 1993 smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108(Nail-On) Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108(Mortar Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering,Inc. TAS 101 (Mortar Set) The Center for Applied 25-7094-(2,5,&8) Static Uplift Testing Oct. 1994 Engineering,Inc. TAS 102 The Center for Applied 25-7183-(5 thru 6) Static Uplift Testing Feb. 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7214-(1,5 ,&8) Static Uplift Testing March, 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7487-2 Static Uplift Testing Dec. 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7496-(1 &4) Static Uplift Testing Dec. 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7804-6 Static Uplift Testing Sep. 1996 Engineering,Inc. TAS 102 Celotex Corporation Testing 520109-1 Static Uplift Testing Dec. 1998 Service 520111-4 TAS 101 Celotex Corporation Testing 520191-1 Static Uplift Testing March 1999 Service TAS 101 Walker Engineering,Inc. Calculations Aerodynamic Multiplier Sep.2006 Walker Engineering,Inc. Calculations Restoring Moments Due to Gravity Sep.2006 NOA No.:12-0430.04 M Expiration Date:10/05/16 Approval Date: 08/02/12 Page 3 of 10 3. LEWrATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix`A'.Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Bel Air,Bel Air Double Eagle,Ponderosa,Golden Eagle,Ponderosa Double Eagle Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W)and Dimensions (I x w) Tile Profile Weight W(Ibf) Length-I (ft) Width-w(ft) Bel Air, Bel Air Double Eagle, 11.4 1.42 1.03 Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile Table 2: Aerodynamic Multipliers -A(ft ) Tile Profile A(ft ) A(ft ) Batten Application Direct Deck Application Bel Air, Bel Air Double Eagle, 0.301 6.278 Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile � NOA No.:12-0430.04 o Expiration Date:10/05/16 Approval Date: 08/02/12 Page 4 of 10 Table 3: Restoring Moments due to Gravity-Mg(ft-lbf) " " The 3 :12 CAT'2 5 .12 6 .12 Greater than Profile 7":12" Bel Air, Bel Air Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Double Eagle, Deck Deck Deck Deck Deck Ponderosa, 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07 Golden Eagle, Ponderosa Double Eagle Flat Tile Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Nall-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Bel Air, Bel 2-10d Ring Shank Nails 30.9 38.1 17.2 Air Double 1-10d Smooth or Screw 7.3 9.8 4.9 Eagle, Shank Nail Ponderosa, 2-10d Smooth or Screw 14.0 18.8 7.4 Golden Shank Nails Eagle, 1 #8 Screw 30.8 30.8 18.2 Ponderosa 2#8 Screw 51.7 51.7 24.4 Double 1-10d Smooth or Screw 24.3 24.3 24.2 Eagle Flat Shank Nail Field Clip) Tile 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail Eave Clip) 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails Eave Clip) 2-10d Ring Shank Nails'- ails 50.3 65.5 48.3 1. Installation with a 4"file headiap and fastemers are located a min. of 2Y2"from head of tile. NOA No.:12-0430.04 MADE couPrrY Expiration Date:10/05/16 Approval Date: 08/02/12 Page 5 of 10 i Table 6: Attachment Resistance Expressed as a Moment Mt(ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Bel Air, Bel Air Double Eagle, Adhesive 31.3 Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Tile 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. 3MTm 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 arams. Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bel Air, Bel Air Double Eagle, 3M 2-Component Foam Roof Tile Adhesive AH-160 118.9 Ponderosa, Golden Eagle, 3M 2-Component Foam Roof Tile Adhesive AH-160 40.4 Ponderosa Double Eagle Flat Tile 3 Large paddy placement of 45 grams of Pol ProTm. 4 Medium paddy placement of 24 grams of Pol ProTm. Table 7: Attachment Resistance Expressed as a Moment-Mt(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Mortar Set 43.9 Eagle, Ponderosa Double Eagle Flat Tile 5 Tile-Tite Roof Tile Mortar. i NOA No.:12-0430.04 rgaMummc2IMUM Expiration Date:10/05/16 Approval Date: 08/02/12 Page 6 of 10 5. LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below),or following statement: "Miami-Dade County Product Control Approved". EAiGLTi FLORIDA BEL AIR,BEL Ant DOUBLE EAGLE,PONDEROSA,GOLDEN EAGLE,PONDEROSA DOUBLE EAGLE CONCRETE ROOF TILE LABEL,SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TII.E) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.:12-0430.04 hnwaoe Co� Expiration Date:10/05/16 Approval Date: 08/02/12 Page 7 of 10 PROFILE DRAWING ir 12%a 3 BEL AM it BEL AIR DOUBLE EAGLE NOA No.:12-0430.04 CH C� Expiration Date:10/05/16 Approval Date: 08/02112 Page 8 of 10 i I PONDEROSA sli itYi i PONDEROSA DOUBLE EAGLE NOA No.:12-0430.04 woe Expiration Date:10/05/16 Approval Date: 08/02112 Page 9 of 10 i Y 4 "Irk— GOLDEN EAGLE END OF THIS ACCEPTANCE NOA No.:12-0430.04 MIAMMME COVE Expiration Date:10/05/16 ,...f Approval Date: 08/02/12 Page 10 of 10 r KIAN MIANII-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERNIITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 _NOTICE OF ACCEPTANCE (NOA) www.miamidade.$ov/sera 3M Company 3M Center Building 0220-05-E-06 St.Paul,MN.551441000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION;:3Mrm 2-Component Foam Roof Tile Adhesive AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11-0 124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA 14o.:12-0228.18 WADE C" Expiration Date:05/10/17 Approval Date:05/10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable building code,does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127,for use with approved flat,low,and high profile roof tiles system using 2-Component Foam Roof Tile Adhesive AH-160.Where the attachment calculations are done as a moment based system for single patty placement,and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack®30& 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX- PHYSICAL PROPERTIES: Provertv Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Fe Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% NOA No.:12-0228.18 Expiration Date:05/10/17 ruart�nEwe COUMY Approval Date:05/10/12 Page 2 of 7 I Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMIT:rED: Test Agencv Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LuAiTATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. ce for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 4. Roof Tile manufactures acquiring acceptance p q 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. C F — W 2 MS NOA No.:12-0228.18 Expiration Date:05/10/17 C � Approval Date:05/10/12 JAPPROVEDI Page 3 of 7 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance,expressed as an uplift based system,to meet or exceed the uplift resistance determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A"component and the"B"component shall be maintained between 1.0-1.15(A): 1.0 (B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or ProPack®30& 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshl y applied lied adhe sive.Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. i Table 1:Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per Mn.(grams) paddy Min.(grams) Flat,Low,I-ligh Profiles #1 35 N/A Ifig4 Profile 2 Piece Barrel) #1 17/side on cap and 34/ an N/A Flat,Low,High Profiles #2 24 N/A Flat,Low,High Profiles #3 8 NOA No.:12-0228.18 Expiration Date:05/10/17 MIAMMADECOMMM Approval Date:05/10/12 ,...• Page 4 of 7 LABELING: All 3MTm 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nag through*do mmt lion enough plaft cannuft underwyment 1 1 - __ 0 hi io 21 EMU= ------ Fula EMCON FOS& Weepm Muse MY. Em cause on1r. KwdW"apmL KOBPWWWV� Imp edge Emann 4 hL up from nepWas 4 ht up from weephdo Opdond 2KIVS for No through pledc cement Pa*Memo Too) 1)Plow enough adhesive to addeve V to 23 *q Pfth"Pucebm flail through canned square hithes in contact with the pan tue 2)Tm 112 h Tole-=M edge d wWft Then InsW the tile. 0 Undedq=rd 101n. hL IMCINDS1 0 Enefto EMCMMO*. " frouaawepholas Ko Mop Fewle Ottbeeave coursecomme. $hed Abuttoncood woes d opbud pan toes.bsurvemendof pan and comVes am thresh ateaveft edgesoffle Em dommue wee 010 Fosde L(Troftshown) NOA No.:12-0228.18 Expiration Date:05/10/17 MIAMFDADECOUNTY Approval Date:05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nap through plastic cement Paddy(Beneath TOO) Nag through plastic cement Paddy RmsA TOO) Undwlaymetd .� Undedayment 1 7'I . tin 71n iin Ears Coosa . Fascia Fascia WeepMe Em Come Eere closure UP edge Em Closure Nail through plastic cement Paddy(Beneath Tpe) Unddgment 71n. i M Ears Closure EmC=w Fascia NOA No.:12-0228.18 Expiration Date:05/10/17 MIAMM14DECOUNTY Approval Date:05/10/12 ,110 a Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Pa* Nall through plastic cement Single paddy under Ifis (between tile) Undedayment Single paddy between tile Paddy 2 In.x 7 In.medlum (under 119) size paddy me course only Mn I paddy INK 1 n x 3 In In. und r tile 3 In. Single In. 2 In. rIx 11 Single Single paddy on 0 2 In. 4 In. paddy on under- under- la layment Single paddy Fascia Eave on top of tile Weephole I Em Single paddy In.X 71n.medum % Come Em closure osure on top of Me size paddy eave Dylp edge Fascia course only L Nag through plastic cement Single paddy under file Single paddy between tile P"TIn.X 3 In. 41n. Single paddy on undeflayment 2 0 'Ingle paddy Em Closure on top of tile 21n.k I In,medium Eave Mass paddy eave course only Fee I END OF THIS ACCEPTANCE NOA No.: 12-0228.18 Expiration Date:05110/17 MIAMFDADE COUNTY Approval Date:05/10/12 JAPPROVED Page 7 of 7 Miami shores Village Budding Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305)756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores,Fl 33138 Re: Owner's Name: ?!z Property Address:' N!zt�JE=�� Roofing Permit Number. Dear Building Official: ft 01� (Jovy,,,.qLA certify that I am not required to retrofit the roof to wall connections of my building because: ❑The just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) IV. V�rN Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of o PGg, EdbA 1 POUSO ; Notary Public-State of Florida :•: •= My Comm.Expires Oct 4,2016 Notary Public, Sate of Florida at Large %, ° Commission#EE 207519 ''FOi.. Beaded Through National Notary Assn. When the just valuation of the structure for purpose of ad valorem taxation Is equal to or more than$300,000.00,and the buNng was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/2112409 Miami-Dade My Home Page 1 of 2 My Home _ M[LAM I�DADE s a a Show Me: Property Information Legend Search B Property Y� Boundary Select Item{ Selected ........ ....... �; 1,.,. ° Properly Text on " 3)STN-$ Property Appraiser Tax Estimator Street Property Appraiser Tax OW Highway Comparison Miami- - Dade Portability S.O.H.Calculator l County 1tT{N' Water Summary-0emas• a o , ti�3aos c -9 i�: 813 NE 97 ST OBERT WHANNAU 'i W+ dregs§ ---- 13 NE 97 ST MIAMI HORES FL 138-2527 -� Property Information• ma Zone: 1100SGL FAMILY- ' 2301-2500 SQ 1 RESIDENTIAL- INGLE FAMILY Aerial Photography-2012 0 112 ft l) opts e: 938 400 SO FT i 'Bui(t: 1951 IAMI SHORES SEC 3 B 10 37 LOT 14&W1/2 My Hopes I,warty Information I Prone Taxes egal F LOT 15 SLK 73 LOT Neighborhood Pro A raiser on: IZE 75.000 X 112 OR My gh � BR 16328.0391 04941 OR 1,6,326,-,03910494 00 Home I Using Our Site I Phone Directory I Privacy I Disclaimer Assessment Information: y:`- 2013 2012 s .- AiWes--=-= 19 489 $91159 il��nq,vatue_--- 1sd'147 yea 31 If you experience technical difficulties with the Property Information arenrat,,ue: 27a Ste 27s a7 application, seed value. $157 Information:154 or wish to send us your comments,questions or suggestions Exem on Informaat 2013 1 2012 please email us at Webmas% $26,000 5000 YES I YES Taxable Value Information: Web Site ear. 1 2013 2012 ©2002 Miami-Dade County. Applied Applied All rights reserved. Taxing Authority: Taxable Exemption/ Taxable Taxable Value: Value: sgional $501000/ $501000/ 1107,00 $104 408 $501000/ $501000/ 07.030 $104,406 $50,000/ $50,000/ $107,030 $104 408 oof Board: $25,000/ $25,0001 $132,030 129408 Sale Information: http://gisims2.miamidade.gov/myhome/propmap.asp 7/3/2013