EL-13-1563 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-195163 Permit Number: EL-7-13-1563 Scheduled Inspection Date:August 27,2013 Permit Type: Electrical- Residential Inspector: Devaney, Michael Inspection Type: Final Owner: FRANKLIN,TRACY Work Classification: Generator Job Address:77 NE 100 Street Miami Shores, FL 33138- Phone Number (917)826-6492 Parcel Number 1132060131430 Project: <NONE> Contractor: LONGMAN ELECTRIC INC Phone: (305)758-1211 Building Department Comments INSTALLATION OF 20KW STAND ALONE GENERATOR Infractio Passed Comments INSPECTOR COMMENTS False ICI Inspector Comments Passed E�f Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 26,2013 For Inspections please call: (305)762-4949 - Page 15 of 38 R Miami Shores Village _ 3 � Building g 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 JUL 12 2013 Tel:(305)795.2204 Fax:(305)756.8972 INSPECTION'S PHONE NUMBER:(MS)762.4949 FBC 20 BUILDING Permit No.:E-115 153 PERMIT APPLICATION Master Permit No. Permit Type: Electrical JOB ADDRESS: 7 7 oN )on �f� City: Miami Shores County: Miami Dade Zip: 3 31 3.,0 Folio/Parcelt f / — 3 Q 0 6 d 1 .7 — 1 9 .3 0 Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): .T- yG�j rkra V ii. e Phone#: CD 1 -,8v26-° 91 i�- Address: 777 Al f- )0th z e City: 4177,- J6 PZ 5 State: li Zip: 3 3 15 Tenant4xssee Name: Phone#• Email: CONTRACTOR:ppCompany Name: C� �✓' '/j/ Phone#: 30Jr-75 Address: 33 q_/ .-I� 9 °l J°� City: /M/i4.,. - State: Zip: � ) 3.13 Qualifier Name: Mj G&7 Phone#: 5- 759 1A// State Certification or Registration#:E[, )_?r)o 3:]J 3 Certificate of Compete�njcy:#: Contact Phone#: 3-0%r-757$ -1 / Email Address: 1-cw&m nne-)et DESIGNER:Architect/Engineer. Phone#: Value of Work for this Permit:$ L7, 000, !P,9 Square/Linear Footage of Work: Type of Work: OAddress OAlteration JaNew ORepair/Replace ODemolition Description of Work: :9�4 f-4)1 44�'V4/ Qf _9,62 )Alf :� K/ A4 ft �/ Submittal Fee$ Permit Fee$ A j CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ jStructural Review$ TOTAL FEE NOW DUE$ s Bomoing Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CONaVIENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a rek7ection fee will be charged r Signature Signature weer or Agent Contractor The forep oin trument was acknowledged before me this The foregoing instrument was acknowledged before me this_]_)__ day of 1 ,20_t3,by 'rr g- 1��, day of 20 13,by 1-A:1- ,2 1 U01 o.i+? has produced AS Ale- who is perso� y kn n.__ Jo me or who has produced Notary PubBC State� _...._-.----_.._ . Michelie PprAs identificati and who did take an oath. as identification and who did take an oath. My M nmi^ Inn k ')UU 1 4 NOTARY PUBLIC: . ' l Sign: Sign. Print: dQbfiw Public of Flodde Print: NOfa Florida . ir, alln My Commission ss,..n r. , > My Commis Amy commiss�n FF 000321 EXPireS 0410812017 y ffia�+e9��k ��aaR���s��ta���Is�sRlds$ak�$e�8vt����Aa APPROVED BY / Plans Examiner y' Zoning i � 117 Structural Review Clerk I (Revised 3/1=012)(Revised 07 1101Mnevised 06110nM)(Revised 3/15/09) NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTIOIC FM 21�13 R C,15 5 3 4,C14 OR BE: 2 8723 P9 1764; (1p9) RECORDED 07/15/2013 PERMIT NO. EL� ��)3 ®IS6� TAX FOLIO NO.I I-�aD�–D13--I�13GtlARVEY UVTNP CLERK OF COURT �{IAl'{I-GAGE CDUNTYr FLORIDA STATE OF FLORIDA: LAST PAGE COUNTY OF MIAMI-DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and stmt/address: -�� N ►Doti Sykes' /li-,. ,," � I�eS , 3313.8 2. Description of improvement. ivy llR �sv &IC 3. Owner(s) name and address: t o �-- Interest in property: f7 i,-✓-Ayeds Name and address of fee simple titleholder. 4. Contractor's name and ad ress• „ 1, Av 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond$ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: �' s�yLs 8. In addition to himself, Owners designates the following person(s)to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Addr L 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) S' nat a of Owner 1 Print er's Name—(_ rrc,c 1 ,rw. %L �n Prepared by 42j"" _u z �iys 4,6L Swom to and subscribed before me s day of 20 Address: �Pe.6t- Notary Public: -� a S i-e Print Not My Corn ply Mi Pub) on . Che ere a� My CommWWw FF 000321 Expkes 04/08/2017 r s : R tt 1 �• E.1/2.-LOT-19 1 7 � '1 1 n Y 1 ISMS- W.1/2 LOT-21 •!r1 ) rC Ill Gwr / F �= ! rr. riw �.1iia� Lil�'' r wwirii BLOCK-1 1 i"rr r�'� •+.w rr lrr.�1 '1 • 1 " uir ���i•ti 51 �rrrrrrrrrr\ '1 • 1 ��� °or.r rr rlrrrr rrlrrrr 25 1 .r r arrr•iirrrrraZrrrlrr . rrrrrrrr rr��ri 1 • rrr�rr � 1 ^a��r.�.a-fir tax_�.i:■ � y4� YIllrrrrl.�1 r��• rrrrrr� =rrrrlrl • rrrrr. irrrrr =i=rr ■lrrrri+ � PARKWAY rrrrrr. �rrrrrr� rrrrrw rrrrrr. �r•:rrrr rrrrr I�rw��=rr■ �rrrrrr• rrrrrrr irrrrrri�� iirrr��r rrrr� rrrrr r.� MB Von= MIE V z'q ri) n PERMIT #: UK 2E .� _ ;a c - MIAMI SNORES VILLAGE � T w APPROVED EY DATE N V co � � o ZONING 0-jx/� ° T = C7 STRUCTURAL v a ► ao x — t w ELECTRICAL D Z z N N PLUMBING p o ag x MECHANICAL BLDG. n m .r SUBJECT TO COMPLIANCE WITH ALL FEDFi:� STATE AND COUNTY RULES AND REGULAV i 77 NE 100th Street Tracy Franklin LOAD CALCULATION 2484 sqft x 3VA= 4950 Small Appliance 3000 Laundry 1500 Dishwasher 1000 Microwave 1200 Dryer 5000 pump 1200 Refrig 1000 18850 -10000 8850 10000 x 40% 3540.00 3540.00 13540 10000 air conditioning 23540 full VA 23540 / 240 = 98.08333 amperage Longman Electric EC 13003713 844 NE 98 Street GENERAL 14/17/2OkW CMITY GUARDIAN®SERIES C A11ftk upy Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating • True Power" Electrical Technology Models 006240-0,006241-0,006247-0(Steel-Bisque)- 14 kW 6OHz • Two Une LCD Multilingual Digital Models 006242-0,006248-0 (Steel- Bisque)- 17 kW 60Hz EvolutionTM Controller (English/Spanish/ Models 006243-0,006249-0(Aluminum-Gray) - 17 kW 6OHz French/Portuguese) Models 006244-0,006250-0 (Aluminum-Gray)-20 kW 6OHz • Two Transfer Switch Options Available: . .r 100 Amp Pre-Wired Switch or 200 Amp Smart Switch. See Page 4 for Details. • Electronic Governor • Extemal Main Circuit Breaker, _ ! System Status& Maintenance - Interval LED Indicators • Sound Attenuated Enclosure °•«+�- its • Flexible Fuel Une Connector �- • Composite Mounting Pad • Natural Gas or LP Gas Operation C @ OS Lffm • 5 Year Limited Warranty Note:CUL ce0cafion only applies to unbundled unb and units packaged with pre-wUed swihdtes. Capability to be installed within 18° of a building* Unds packaged with the Smart Switch are UL certified in the USA only. • *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. FEATURES • INNOVATIVE DESIGN&PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in"IMPROVING POWER BY DESIGN."But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and fife testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±11%. systems will provide superior performance. • TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics o SINGLE SOURCE SERVICE RESPONSE from Genemc's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the erdire wit,from the utility quality power.This allows confident operation of sensitive electronic engine to the smallest electronic componeft equipment and micro-chip lased appliances,such as variable speed HVAC systems. O GENERAL TRANSFER SWITCHES. Long life and reliability are • TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED NEMA MG1-22 EVAWATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC• + my r GENERAC® 14/17/20kW features and benefits Engine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau ironed cylinder walls and plasma molt'rings helps the engine nm cooler,reducing oil consumption resulting in longer engine life. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. -Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator -Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving arrature generator. -Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. *Displaced phase excitation Maximizes motor starting capability. *Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. -UL 2200 listed For your safety. Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power. -Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items. -Remote mounting Mounts near your existing distribution panel for simple,low-cost Evolution'" Controls •Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. •Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 10 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •Programmable seven day exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every week. •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. -Main line circuit breaker Protects generator from overload. •Electronic governor Maintains constant 60 Hz frequency. Unit -Weather protective enclosure Ensures protection against mother nature and can withstand winds up to 150mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. -Small,compact,attractive Makes for an easy,eye appealing installation. *SAE Sound attenuated enclosure ensures quiet operation. Installation System •1fL(305mm)flexible fuel line connector *Composite mounting pad Posy installation. GENERAL® 14/17/20kW specifications Generator Modd 002404,006241-0. 006242-0,006243-0,006248-0,006249-0 a�(2igldN)0 006250- 008247-0,(14 kYf) (17 kW)flared Maximum Continuous Pour Capacity(LP) 14,000 Waits* 17,000 Wafts* 00 Watts` Rated Maximum Continuous Power Capacity(NG) 14,000 Watts* 16,000 Wafts* 18,000 Wafts* Rated Voltage 240 .240 240; Rated Maximum Continuous Load Current—240 Volts(LP/NG) 58.3158.3 70.8166.6 83.3/75 Total Harmonic Distortion Ins than 5% LOSS than 5% Less#on:5% Main Line Circuit Breaker 60 Amp 65 Amp 90 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 6OHz 60Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement{not included) Group 26%12 Volts and 525 CCA Minimum Unit Weight(PoundWlos) 435/197.3 471/213.6(Steel);437/198.2(Aluminum) 451/204.6 Dimensions(L x W x H)inJmm' 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A)at 23 it(7m)with genetator operating at normal load** 66 66 66 Sound output in dB(A)at 23 ft(7m)with generator In QUlet-7eSt-low-speed exercise'mede** NA 60 60 Engine Type of Engine GENERAC ON VT'WIN GENERAC ON V-7iiVIN GENERAC ON 1!:"tUV N Number of Cylinders 2 2 2 Displacement 992cc 992cc 999cc' Cylinder Block Aluminum w/Cast Iron Sleeve Valve Anangemerd Overhead Valve Ovedead Vahra 1Tyeriutad VVatVe Ignition System Solid-state w/Magneta Solid-state w/Magneto Solid-state 04agne10 GovemorSystem Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12 V& Oil Capacity Including Filter Approx.1.9 QtsJ1.81 ApproL 1.9 MJ1.81 Appmx 1.9 QisJ1.8L Operating RPM 3,600 3.600 9,600 Fuel Consumption Natural Gas ft3/hr(m3/hr) 112 Load 177(5.01) 193(5.47) 205(5.8) Full Load 279(7.9) 312(8.83) 308(8.72) Liquid Propane tt3/hr(gal/hr)[Litars/hr] 1/2 Load 67.2(1.85)[6.99] 72.4(1.99)[7.53] 75.6(2.08)[7.87] Full Load 111.6(3.07)[11.61] 130(3.57)[13.53] 140(3.85)[14.57] Note:Ftrol pipe MWbe stied for toll teat!.Required fuel pressure to generator fuel Inlet at all load ranges-3.5-71 water column(7-13mm merm-)for m Wad gw 1042"watar column(19-22mm memq)for LP gas.ForBtu comem,multiply ft3Aj x 25M(LP)ort3/br x 1000(NO).For Megajoule content,multiply 9offirx 93.15(M:Or m%rx 3726(Ng) Controls 2-Une Plain Ted Multilingual LCD Display Simple user irftka tM ease of operation.. Made Buttons: Auto Automatic Start on Utility tailure.7 day awdser. Manual Start with SWW control,Will stays on.U utility falls,bansforto load takes oboe. Off Stops unk Parer Is removed.Cwftl and charger still operate. Ready to RwAYSIntanance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard Omgrammable by dealer only) Utility Voltage LmMetum to Utility Adjustable From 140-171V/19O-216V Future Set Capable fxercW/Exercise Set Enor.Warning Standard Run/Alarm/Maimenance hogs 50 Evards Each Engine Sian Sequence Cyclic co mift:16 sec.on,7 rest(90 sec.maximum dumuch). Starter Lock-out Starter cannot re-engage until 5 sec.after engine has slopped. Smart Battery Charger Standard Charger FoufVMissing AC Warning Standard Low B ry/Battary Problem Protection and Ball"Condition Indication Staadarp Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under Frequency/Overioad/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil PresstOefth OilTempembae Shutdown Standard OveraanWOverspeed(p 72Hzy"Serve Loss Shutdown Standard High Engine Temperaftrre Shutdown Standard Internal FaulUlncorrect Wiring Protection Standard Common External Fault Capability Standard Frew Upguadable Firmware Standard *"Sound levels are taken from the trod of the generator.Sound levels taken from other sides of the generator may be higher depending on Installation parameters.Rating definitions-Standby:Applic able for supplying emergency power for the duration of the utility power adage. No overload capability is available for this ailing. (All ratings In accordance with BS5514,IS03046 and DIN6271). *Maximum wattage and current are subject to and limited by such factors as fuel Bbt/megajolle content,ambient temperature,altitude,engine paver and condition,etc. Maximum parer decreases about 3.5 percent for each 1,0M feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6*C(10°F)above 16*C(60*0. GENERAC® 14/17/200 switch options Pre-wired Features III 006240-0(14 kW) OM42-0(rnW) available on 14&17kW models only No of Poles 2 2 • Electrically operated,mechanically-held contacts for fast,positive Current FMn9(Amps) 100 100 connections. Voltage Rating(VAC) 250 1201 40,10 Utility Voltage Monitor(Fixed)* •Rated for all classes of load,100%equipment rated,both inductive and wick-up a 80% resistive. -DmpW 60% 60% •2 pole,250 VAC contactors. Return to Utillhr* - approx.15 sec. approx.is sec. Exercise weekly for 12 minutes* Standard Standard • 30 millisecond transfer time. UL Listed Standard Standard Total of Pre-wired Circuits 14 16 • Dual coil design. No.15A 120V 4 5 4 • Main contacts are silver plated or silver alloy to resist welding and sticking. No.20A 0V 6 5 No.20A 2 240V 1 1 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch. No.30A 240V - - No.40A 240V 1 1 • Pre-wired 30 foot(9.1 meter)whip to connect to the provided 5 foot pre- No.50A 240V - 1 wired whip and external connection box. Circuit Breaker Prod Available RW Symmetrical • Pre-wired 2 foot(0.61 meter)whip,color coded to connect into the Fault Current 0 250 dolts 10,000 10,000 existing electrical panel. *Function of Evolution Controller Dimensions memftw Dimension Height width krips H1 H2 I wi w2 Depth H2 H9 100 23.5 in 26.4 in 8.3 In 12.6 In 6.3 597mm 671.7mm 211mm 320.7mm 159.6mm Wire Ranges Am s Conductor Lug Neutral Lug Ground Lu 100 210-#14 210-#14 2/0-#14 I w+ Smart Switch Features Me" 00241-0(141dfi Y=48-0(17kIN)/006244-0(200) • Includes Digital Power Management Technology standard(DPM). No.of Poles 2 • Intelligently manages two air conditioner loads with no additional Current Rating(Amps) 200 Volthge Rating(VAC} 1201240,101 hardware. Utility Voltage Monitor(E'ud)' • Up to four more large(120J240VAC)loads can be managed when -Ptck-ap 80% used in conjunction with Poorer Management Modules(PMM**). Dropmd 60% Return to Utility* apps 13 sec. • Electrically operated,mechanically-held contacts for fast,clean Exercise weekly for 12 minutes* Standard connections. UL Usted Standard Enclosure Type NEMANL 311 • Rated for all classes of load,100%equipment rated,both inductive Withstand Rating(Amps) 22,000 and resistive. Lug Itmge 250MCM-#6 • 2 pole,250 VAC contactors. *Function of Evolution Controller •Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. •NEMA/UL 3R aluminum outdoor enclosure. Vn • Main contacts are silver plated or silver alloy to resist welding and sticking. **Note:PMM starter kit is required prior to using the modules. HR Dimensions 200 Amps 120/240,1a Open Tiarsttion Service Ram Height width Depth H1 H2 wi I w2 Inches 27.24 1 30.0 11.4 1 13.5 1 7.09 ' mm 692.0 762.4 289.0 343.0 180.0 °'�""' �M2—� GENERAC® 14/17/2OkW available accessories Model# turd 0=41" 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product 006212-0 Cold Weather Kit If the temperature regularly falls below 32OF(0°C),Install a cold weather Idt to maintain optimal battery and oil temperatures. KIt consists of a battery warmer and oil filter heater with but&in thermostats. 005621-0 A liary Transfer Switch Contact The auldliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Kit you may not need.Not compatible with 50 amp pre-wired switches. 005839-0-Bisque Fascia Base Wrap Kit* The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers 005666-0-Gray (Standard on 20kM a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 005703-0-Bisque N the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from 005704-0-Gray Paint Kit* future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0-14&17kW Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine X5-0-20kW maintenance on a Generac automatic standby generator. 005928-0 Wireless Remote Completely wireless and battery powered,Generac's wireless remote monitor provides you with instant status Information without ever leaving the house.Not compatible with CorePower or EcoGen systems. Remotely control generator functions with the advanced model's LCD display.In addition to.remote 005951-0 Advanced Wireless Remote testing of the generator,set the excerclse cycle and maintenance Interval reminders.Not compatible with CorePower or EcoGen system. The PMM Starter Kit consists of a 24VAC,field installed transformer that enables the use of the 24VAC 006199-0 PMM Starter Kit Power Management Modules(PMMs)and one PMM.The standard controller(without starter ldt)can control two WAC loads with no additional hardware.Not compatible with pre-wired switches. Power Management Module(50 Power Management Modules are used in conjunction with the Smart Switch to increase its power 006186-0 Amps)) management capabilities.it gives the Smart Switch additional power management flexibility not found In any other transfer switch.Not compatible with pre-wired switches.Note:PMM Starter Kit required. Generac's Mobile Link device allows you to check the status of your generator from anywhere that you 006463-0 Mobile Link'Device have access to an Internet connection from a PC or with arry smart device.You will even be notified when a change in the generator's status occurs via"WI or teud message. *Note:Bisque kits are used in conjunction with steel enclosures.Gray kits are used In conjunction with aluminum enclosures. dimensions Dknft=sh=nvwmftft coral you dealer 1w cMed drawings DO nor USE RM D&ENS NS m I O&LAWNN FINOSES. 637.6 mm [25.1 tn., 12,e mm 14791n., 7319 mm tzee m., p p 642 mm Piz k, 7e2 OUN VU 148.3 Wj MNMUM LEFT SIDE VIEW FRONT VIEW GENERAC• Generac Power systems,Inc. •S45 W29290 HWY.59, Waukesha,WI 53189•generac.com 02013 Gmmm Power Syshm.hx.M Vft reserved.All spy are su*d to charge wMW nagm Bubb 019799US6Y-F MM to U.SA.05/19/13 Air-Cooled Generator Pad GMMW Not. To be used only with Fiberlitte concrete pads produced by ALL TIE DOWN POINTS TO BE INSTALLED A MINIMUM ALL TIE DOWN POINTS TO BE INSTALLED A MINIMUM FRCC Products only. OF 4 INCHES FROM EDGE OF CONCRETE PAD. Anchor Point OF 4 INCHES FROM EDGE OF CONCRETE PAD. Ali design completed in Fiberiite Concrete 3-#8 Self-tapping metal screws accordance with ASCE 705, Generator Pad air-cooled at each bracket location 201017W. " $ JUL 2 9 2093 generator " " " System designed to meet 56.0" 4 x 1Yz x Y,s Gaiv L-Bracket ovetum moment and uplift produced by 175 mph,3 sec wind gust with a minimum - — Ya"x 2"Tapcon and Galley factor of 1.5. a °'' ° gaiv.fender washer °• ° ° min generator frame All hardware to be corrosion °t a:•° I. ' °. 4" TOX MKD 860 Anchor � �steel � d G 4 ° ° plastic pad otherwise approved by v 4 a° d (manufacturer supplied) engineer. `°° ° °° Generator v Ground to be prepared by 40.0" d° d d d �l 1 removing sod and piecing compacted road grade gravel a. ' { ° v . Q to prepare site for slabs. . ° A • d G .v',d .. I�l 4 d 4.5" Site soil density has not been WA ° evautuated in preparing this °• . ° v °' a v ° design. Soil bearing capacity assumed to be capable of ° a FRCC Pr ucts 171berlite Concrete Pad supporting slab and generator. min 4" Report to N field conditions To View - Slab To View with Generator Anchorin Dia � �i od�rlas ram to be 1 Scale: 1:20 Scale: 1:20 male: NTS determined by is the authority having jurisdiction and FEtJIA. C oft iTy This tie down specification and drawings are suitable for the following generators: Generac Models: Anchor Point Air-Cooled Typical Air-Cooled Generac Anchor Point 8/7kW t 7=,t Generac Generator Concrete Pad Generator 10/9 kW Plastic Pad 14/13 kW (manufacturer supplied) Concrete Pad .tom 4.5" 17/16 kW (steel and aluminum housings) Richard Zimmer,PE Gravel Base 20/18 kW 129 NW 13th street,suits#20 C• Boca Raton FL 33432 ? s4 • • r' :. �• s,. t + 9 +• a,. .. v o•+ .,K; Phone:(561),391-6917 t$•7a' *�' 14i yh i•`i�e'+ ; r v ^t.•. yis.•srr}'►;�/., o.� t8:► �,°d3 •yK, PE#:16095 Grade '� + •�• :Y-z` 'r ��jL' �:�•��:• .r..° rr«� 4 '.t •• fit•..?r• W.• Grade Other generators may be used. For ,i.a . .osr• s: 'r r..� .y 4ty~•.,:. !+s y .pia ,u.t_,.• �l: i... .:'• • approval see engineer prior to installati PWIM No=and 4 Prof le View 5 Profile View Scale: 1:16 Scale: 1:16 Generator Slab REVISmi r �� s� ArR1L23 x-% S_1 as noted