RF-13-1348 • r - 1
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-196745 Permit Number: RF-6-13-1348
Scheduled Inspection Date:August 12,2013 Permit Type:
Inspector: Rodriguez,Jorge Inspection Type: Final Roof
Owner: ALLEN, PHILLIP Work Classification: Tile/Flat
Job Address:107 NW 96 Street
Miami Shores, FL
Phone Number
Parcel Number 1131010250090
Project: <NONE>
Contractor: DEL SOL ROOFINGENTERPRISE INC Phone: (305)229-5722
Building Department Comments
RE ROOF TILE AND FLAT ROOF Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-193618. Supply renailing
affidavit
Failed
Correction ❑
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
August 12,2013 For Inspections please call: (305)762-4949 Page 21 of 41
I
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-193618 Permit Number: RF-6-13-1348
Scheduled Inspection Date:August 06,2013 Permit Type: Roof
Inspector: Rodriguez,Jorge Inspection Type: Final Roof
Owner: ALLEN, PHILLIP Work Classification: Tile/Flat
Job Address: 107 NW 96 Street
Miami Shores, FL Phone Number
Parcel Number 1131010250090
Project: <NONE> �
Contractor: DEL SOL ROOFINGENTERPRISE INC Phone: (305)229-5722
Building Department Comments
RE ROOF TILE AND FLAT ROOF Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed
Failed
Correction
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
August 05,2013 For Inspections please call: (305)762-4949 Page 13 of 37
l
t
4 rc A U -L A B, I ill--Z C.
July 30 2013
Del Sol Roofing
7570 NW 14 Street
Miami,FL 33126
RE: TILE UPLIFT TEST
PROJECT INFORMATION PROVIDED BY CLIENT:
107 NW 96 St
Miami Shores,FL
Folio#: 11-3101-025-0090
Permit#: RF-6-13-1348
Date inspected: July 30, 2013
Date completed by: July 16, 2013
Roofing Contractor: Del Sol Roofing
Carlab, Inc Project# 13-7715
Testing lab Certificate#: 09-0127.04
Dear Sirs,
In accordance with your request and authorization,a representative of Carlab, Inc completed the Roof
Tile Uplift Test at the above referenced project.This testing was performed in general accordance with
Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of
mortar or adhesive set tile system and mechanically attached,rigid,discontinuous roof systems.
The total of the tested roof surface area was less than 3400 square feet, and the mean height of the roof
is less than 30 feet above ground surface. The type of tile used for this project was reported to be
Santa Fe Spanish S Roof Tile. This tile was reported to have been foamed in place.
At the time of this testing one test was performed for every exterior corner, at least one test for every
100 square feet of roof tile in the perimeter area, and at least one test for every 200 square feet of roof
tile in the field area. The results for this report are valid at the time of testing only. Walking on roof or
any other type of physical disturbance may alter these results.
Based on our test results, we conclude that the installation of the roof the at the above referenced
project meets the test requirement outlined in the above mentioned protocol. Attached please find a
copy of our test report for your review.
Should you have any questions or if we may be of further assistance,please do not hesitate to contact the
undersigned.
Respectfully submitted,
� 4
Sergio Labiste PE 61733
8730 SW 25 STREET• MIAMI • FL• 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
TILE UPLIFT TEST
FOR
Residential Home
107 NW 96 St
Miami Shores,FL
Project#:13-7715
Test Test load Test Test Test load Test Test Test load Test
(lbf) Status (lbf) Status lb Status
1 35 Pass 37 35 Pass 73 35 Pass
2 35 Pass 38 35 Pass 74 35 Pass
3 35 Pass 39 35 Pass 75 35 Pass
4 35 Pass 40 35 Pass 76 35 Pass
5 35 Pass 41 35 Pass 77 35 Pass
6 35 Pass 42 35 Pass 78 35 Pass
7 . 35 Pass 43 35 Pass 79 35 Pass
8 35 Pass 44 35 Pass 80 35 Pass
9 35 Pass 45 35 Pass 81 35 Pass
10 35 Pass 46 35 Pass 82 35 Pass
11 35 Pass 47 35 Pass 83 35 Pass
12 35 Pass 48 35 Pass 84 35 Pass
13 35 Pass 49 35 Pass 85 35 Pass
14 35 Pass 50 35 Pass 86 35 Pass
15 35 Pass 51 35 Pass 87 35 Pass
16 35 Pass 52 35 Pass 88 35 Pass
17 35 Pass 53 35 Pass 89 35 Pass
18 35 Pass 54 35 Pass 90 35 Pass
19 35 Pass 55 35 Pass 91 35 Pass
20 35 Pass 56 35 Pass 92 35 Pass
21 35 Pass 57 35 Pass 93 35 Pass
22 1 35 Pass 58 35 Pass 94 35 Pass
23 35 Pass 59 35 Pass 95 35 Pass
24 35 Pass 60 35 Pass 96 35 Pass
25 35 Pass 61 35 Pass 97 35 Pass
26 35 Pass 62 35 Pass 98 35 Pass
27 35 Pass 63 35 Pass 99 35 Pass
28 35 Pass 64 35 Pass 100 35 Pass
29 35 . Pass 65 35 Pass 101 35 Pass
30 35 Pass 66 35 Pass 102 35 Pass
31 35 Pass 67 35 Pass 103 35 Pass
32 35 Pass 68 35 Pass 104 35 Pass
33 35 Pass 69 35 Pass 105 35 Pass
34 35 Pass 70 35 Pass 106 35 Pass
35 35 Pass 71 35 Pass 107 35 Pass
36 35 Pass 72 35 Pass 108 35 Pass
8730 SW 25 STREET• MIAMI • FL• 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
e '
Test Test load Test Test Test load Test Test Test load Test
(lbf) Status (lb Status Ibfj Status
109 35 Pass 154 35 Pass 199 35 Pass
110 35 Pass 155 35 Pass 200 35 Pass
111 35 Pass 156 35 Pass 201 35 Pass
112 35 Pass 157 35 Pass 202 35 Pass
113 35 Pass 158 35 Pass 203 35 Pass
114 35 Pass 159 35 Pass 204 35 Pass
115 35 Pass 160 35 Pass 205 35 Pass
116 35 Pass 161 35 Pass 206 35 Pass
117 35 Pass 162 35 Pass 207 35 Pass
118 35 Pass 163 35 Pass 208 35 Pass
119 35 Pass 164 35 Pass 209 35 Pass
120 35 Pass 165 35 Pass 210 35 Pass
121 35 Pass 166 35 Pass 211 35 Pass
122 35 Pass 167 35 Pass 212 35 Pass
123 35 Pass 168 35 Pass 213 35 Pass
124 35 Pass 169 35 Pass 214 35 Pass
125 35 Pass 170 35 Pass 215 35 Pass
126 35 Pass 171 35 Pass 216 35 Pass
127 35 Pass 172 35 Pass 217 35 Pass
128 35 Pass 173 35 Pass 218 35 Pass
129 35 Pass 174 35 Pass 219 35 Pass
130 35 Pass 175 35 Pass 220 35 Pass
131 35 Pass 176 35 Pass 221 35 Pass
132 35 Pass 177 35 Pass 222 35 Pass
133 35 Pass 178 35 Pass 223 35 Pass
134 35 Pass 179 35 Pass 224 35 Pass
135 35 Pass 180 35 Pass 225 35 Pass
136 35 Pass 181 35 Pass 226 35 Pass
137 35 Pass 182 35 Pass 227 35 Pass
138 35 Pass 183 35 Pass 228 35 Pass
139 35 Pass 184 35 Pass 229 35 Pass
140 35 Pass 185 35 Pass 230 35 Pass
141 35 Pass 186 35 Pass 231 35 Pass
142 35 Pass 187 35 Pass 232 35 Pass
143 35 Pass 188 35 Pass 233 35 Pass
144 35 Pass 189 35 Pass 234 35 Pass
145 35 Pass 190 35 Pass 235 35 Pass
146 35 Pass 191 35 Pass 236 35 Pass
147 35 Pass 192 35 Pass 237 35 Pass
148 35 Pass 193 35 Pass 238 35 Pass
149 35 Pass 194 35 Pass 239 35 Pass
150 35 Pass 195 35 Pass 240 35 Pass
151 35 Pass 196 35 Pass 241 35 Pass
152 35 Pass 197 35 Pass 242 35 Pass
153 35 Pass 198 35 Pass 243 35 Pass
8730 SW 25 STREET• MIAMI • FL• 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
Test Test load Test Test Test load Test Test Test load Test
(lbf) Status (lbo Status (lbf) Status
244 35 Pass
245 35 Pass
246 35 Pass
8730 SW 25 STREET • MIAMI • FL• 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
N
56
vi F
z
w
a
U
N
N + +
1,D + ++
LEGEND
+ FIELD TEST
— PERIMETER TEST
O CORNER TEST
C A a L A ]B, I N C.
A
ENGUOM AM PLANNM
CEWnFicATE OF At1THOSPmTm 6419
730 B.W.25 Sr,M1UC FL 33165 TM 305 28135125 PAM 305 2260438
APPR❑X, R❑❑F TEST L❑CATI❑NS AND DIMENSI❑NS
.5n R Miami shores Village
loss pevil" Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
1pR'rpA Tel: (305) 795,204
Fax: (305)756.2972
RE: Permit# —�-7�5 —13qt DATE: r 12,611,110
INSPECTION AFFIDAVIT
licensed as a n
Contractor/Engineer/Architect,
(Print name and drde ucense Type) FS 468 Building Inspector
License#: � �.3
On or about I did personally inspect the roof deck nailing and
(Date&time) �.
Secondary water barrier work at
(Complete Job Site Address)
Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit*
Manual(Base 5 F.S)
Signatu
YANELYS DW
State of Florida nnrcogu�sss�orr 7,2015
' >rxra�s:Aau n,xois
County of Dade:
The undersigned,being the first duly swom,deposes and says that he/she is the contractor for the above property
mentioned.
Swom to and subscribed before me this day of ;;,,OX3
Notary Public, Sate of Florida at Large ,-=- ,eA
77�
'General,Bull ft,Residential,or Roofing contractors or any Individual oe Ned under 468 F.S.to make such an Inspection.Include photographs of each plane of the roof vdith
permit#amt address#deafly shown marked on the deck for each Inspection
Revd on 5/21fM
CFN:20130473882 BOOK 28678 PAGE 3926
DATE:06/13/2013 11:14:09 PM
HARVEY RLMN,CLERK OF COURT,MIA DADE CTY
CITY OF MUM—BUII,TIING DF ARTMENT
NOTICE OF COMMENCEMENT
Please file at 22 N.W. 113T Stret>t,1`,Pliami
PERMIT NUMBER.
F01.10 LIJMBlt`R' ' 'c°r..a� Gr/�� (w.+'• °max rFW.../� t.P
S tat2 ctf Florida
County of T%iarrd-Dade:
1 he;-undersigned here-bJ gives notice that improvemerit<s will Enade to eertain real property,and in accordance with
Chapter 71-3.23,Florida Statates, the following in provided in this Notiee of Cornmeneeinent.
Btreat addre:.u..) v ipt and Legal dese nption of propertyff,�y-b
f.)oicription of'im rove.rnent: f.
...-.......... __--__......«-.-._«..........-_ __ ..._-_-__-.-.-......................................... ....
owner(s)B"ITne diu) hi-em and'address: .-- -------«.-.
•
Int meat En property: 4.14
'Name o££ee:simple titielxwder fit other than owrmri t�s;d stc€dre4a _ .w-_----__-_.-..._-......... - '•-",7J °�
'E".'cnLraeta'r•'s t;arne.����'��F �3 � ��_�'•�...anti arltlrsas_��._�...�'�,�`�« �'� �t ..`?�.l..t:�.���_._..........M
Phone ntunlrex:..... _ w �..»_ � ��#_��._� rte
a N
Axroaist of StEiei;>ii�-ni1- a :Ea'ayroc.nt hand required kt_y owner`ruin ecrtractoa.if at3} 8
Surety Name w« «_ »..._.. - -.........._ s.d sddECaa g
Phonerwniborr._.................. .... .,........ ,.3,,.{.._.,_»_......._... _............... g� � _.......------
•r
O
I.entlees niarnti! .........�.._...«.w........... f-- and Address........�----------------............
. ........-..-•--------._....»�..
Phone tFftEnlFf?3': „«,••_••,•„
f\ 4
U
Person's within the st:iva of Florida desigxtated by fJwner.,;apon whortt notices or other documents nsety lily sery
provided.by SectioYS 7 13.13%1fw 7.,�' ri a Sratueas, — _
.o
'INIatt'se:and address: - . ........._kind address .,...... � -----.
CL
- a � a
tes addii:icfn to himself,Owner designates the following per&oa(s)to receive a copy of a Lienor's Notice as Provide
Section 11 W.130.)(W, Florida Statues. e
Name ... —_ .. — ... .. P arid.address- .... •--
°hone rtdrnber: !_ .._ ._.............. M�^-� ..__.......
ii:xpirai.ion flat a of:'t'his:Notice of Coxs:rnr.ixt:eM 1rt: iltsc+c pirntion dac is one W
y,par f'rosr:i.l . a of recording urdes,ix different.dEatc its s€necirled) _....- —�
Pritit.t.'rvrasi<r's Name;
SIGI AT )F 014"NER
z,wu kid 8•ribed - 4a xrt on is � Day of
By... �� .. — w- __.. . persualally Known,or Produced
�
Print'`•lntaryY's Narite• .
Oath talien -C tb not: .4'n___ ...� ......
y
f nu,tni85i0n. Ex0ration: Prera.rf d by '. - z ---•-
-
� � ��
RM* V2004
Miami Shores Villa e
o.nt" Building Department
10050 N.E.2nd Avenue
R Miami Shores, Florida 33138
Tel: (305) 795.2204
-- - - - --- --- - - Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE.
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date:
10050 NE 2nd Ave
Miami Shores, Fl 33138
Re: Owner's Name:
Property Address:
Roofing Permit Number:
Dear Building Official:
n
I certify that I am not required to retrofit the roof to wall connections of my
building because:
/The just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad
valorem taxation.
❑The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)
ez� cz&�d
Signature Print Name
MY�OND�15
State of Florida �+{gES.Z417,x015
County of Dade a
The undersigned, being the first duly swom,deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this /Q day of
Notary Public, Sate of Florida at Large
• When the just valuation of the structure for purpose of ad valorem taxation Is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mdigation.
Revised on 5121/2009
J13 Property Search-Report
MIAMI-DADE COUNTY
OFFICE OF THE PROPERTY APPRAISER
I
PROPERTY SEARCH SUMMARY REPORT
Carlos Lopez-Camera
Property Appralser
Property Information:
Folio 11-3101-025-0090
Property Address 107 NW 96 ST
Owner Name(s) ELLA FALLEN&H PHILLIP
Mailing Address 107 NW 96 ST
MIAMI SHORES FL
33150-1714
Primary Zone 0800 SGL FAMILY-1701-1900
SQ
Use Code 0001 RESIDENTIAL-SINGLE
FAMILY
Beds/Baths/Half 2/2/0
Floors 1
Living Units 1 Miami-Dade County GIS ...
Adj.Sq.Footage 1,544
Lot Size 9,340.3 SQ FT A &rlal Photography 2012
Year Built 1947
Full Legal Description RESUB OF BLK 3 OF BONMAR Taxable Value Information:
PARK
FB 42-60 Current Previous Previous 2
LOT 9 BLK 3 Year 2013 2012 2011
LOT SIZE 81.220 X 115
OR17646-113905974 Exemption/ Exemption/ (Exemption/
IMPORTANT NOTICE Taxable Taxable Taxable
The 2013 exemption and assessment values currently shown are preliminary County $50,000/$42,587 $50,000/$41,040 $50,000/$38,389
and are subject to change until they are certified on July 1.
School Board $25,0001$67,587 $25,0001$66,040 $25,000/$63,389
Assessment Information:
City $50,000/$42,587 $50,000/$41,040 $50,000/$38,389
Current Previous Previous 2
Regional $50,000/$42,587 $50,000/$41,040 $50,000/$38,389
Year 2013 2012 2011
Land Value $84,250 $67,553 $75,059 Sale Information:
Building Value $95,869 $107,086 $107,086 Date Amount OR Book-Page Qualification Code
Market Value $180,119 $174,639 $182,145 5/1997 $0 17646-1139 Sales which are disqualified as a
result of examination of the deed
Assessed Value 1 $92,587 $91,040 $88,389
8/1987 $73,500 13387-0018 Sales w hich are qualified
Benefits Information: 16/19831 $59,000 11836-3201 Sales which are qualified
Current Previous Previous 2
Benefit Type 2013 2012 2011
Save Our Homes Assessment $87,532 $83,599 $93,756
Reduction
Homestead Exemption $25,000 $25,000 $25,000
Second Exemption $25,000 $25,000 $25,000
Homestead
Note:not all benefits are applicable to all Taxable Values(is County,
School Board,City,Regional),
Disclaimer:
The Office of the Property Appraiser and Miami-Dade County are continually editing and updating the tax roll and QS data to reflect the latest property information and
GS positional accuracy.No warranties,expressed or implied,are provided for data and the positional or thematic accuracy of the data herein,its use,or its interpretation.
Although this website is periodically updated,this information may not reflect the data currently on file at Miami-Dade County's systems of record.The Property Appraiser
and Miami-Dade County assumes no'liability either for any errors,omissions,or inaccuracies in the information provided regardless of the cause of such or for any decision
made,action taken,or action not taken by the user in reliance upon any information provided herein.See Miami-Dade County full disclaimer and User Agreement at
http://www.miamidade.gov/info/disclaiiner.asp.
gisweb.Mamida&goVPropert)Gewch/printMap.htm 1/2
� s
Miami Shores Village� R� JUN 13�1013
Building Department
,
10050 N.E.2nd Avenue,Miami Shores,Florida 33138
Tel:(305)795.2204 Fax:(305)756.8972
INSPECTION'S PHONE NUMBER:(305)762.4949
BUILDING Permit No. f�
PERMIT APPLICATION Master Permit No
Permit Type: BUILDING ROOFING
JOB ADDRESS: L 9__;1 &A *! IS
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#:
Is the Building Historically Designated:Yes NO Flood Zone:
OWNER:Name(Fee Simple Titleholder)- GL Phone#:.
Address: 119
City: Al2Agevi 914/P,64�$ State:
Zip: 815 150
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR:Company Name: Phone#: � Kn02—oT
Address: 7"5'4n Ato zy :!g;;r_
s
City: StateL zip:
Qualifier Name: Phone#:
State Certification or Registration#: Certifica a of Competency#:
Contact Phone#:_5Q_5-2Z!9--V ?AV Email Address: •
call, OF
DESIGNER:Architect/Engineer: Phon
Value of Work for this Permit:$ 206 C70 Square/Linear Footage of Work: �?®
Type of Work: ❑Addition ❑Alteration ❑New A(Repair/Replace ❑Demolition
Description of Work:
Color thru tile:
x,xmxm�x����mx�,xmx�,a���x�xmxx��e��xx��xxFeesx,x�xx�a�xxx m���•x��,x�x•xxxx�xxxex�xs,x��saxxx
ara
Submittal Fee$ Permit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Bond$
Notary$ Training/Education Fee$ Technology Fee$
Double Fee$ Structural Review$
TOTAL FEE NOW DUE$ a
• Bonding Company's Name(if applicable) Al
Bonding Company's Address
i
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address t�
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
•
Signature Signature
Owne or Agent Contractor
The foregoingg,instrument was acknowledge b fore m, 's 1 The foregoing instrument was acknowle ged befor this ZP
day of �'�`-e�C ,20137,by day of��("� ,200—,by e"
who is personally known to me or who has produced who is personally known to me or who has produced
As identifi c � n as identification ` o a DIAZ
"` YANEL is NOTARY PUBLI
NOTARY PUB C: myCONMONi7 17�snts
Sao► ��: a
Sign: Sign:
Print: Print:
My Commission pines: My Commission Expir
s<x��s<x+xxxxxsex��x+xxx�xs<+xxxmx*��xxxxxs<�xxxx�xxxxmx�xxxx�xxwx���xxx���x�xxx�x�axa*x���xxxx*�axs<x�xx���s�+��xxx�w
APPROVED BY % Plans Examiner Zoning
Structural Review Clerk
(Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
Issue Date: 1/2/2013
FLORIDA ROOFING,SHEET METAL&AIR CONDMONING CONTRACTORS ASSOCIATION,INc,
RSA ! SELF INSURER •
1-800-767-3772 -FAX(407)671-25M
CERTIFICATE OF INSURANCE
ISSUED TO: COPY PROVIDED TO:
Miami Shores Village Building Department Del Sol Roofing Enterprises, Inc.
10050 NE 2 Avenue 7570 N.W. 14th Street,#111
4Aim ni Shores, FL 33138 Miami, FL 33126
Del Sol Roofing Enterprises, Inc.
This Is to Certify that: 7570 N.W. 14th Street,#111
Miami, FL 33126
being subject to the provisions of the Florida Workers'Compensation Act,has secured the payment of compensation
by insuring their risk with the FLORIDA ROOFING, SHEET METAL&AIR CONDITIONING CONTRACTORS
ASSOCIATION SELF INSURERS FUND, P.O.Box 4907,Winter Park,FL 32793.
COVERAGE NUMBER: 870-033587 LIMITS
EFFECTIVE DATE: 1/1/2013 Workers'Compensation: Statutory-State of Florida
Employers'Liability: $100,000.00 Each Accident
DATE: 1/1/2014 $100,000.00 Disease, Each Employee
$500,000.00 Disease, Policy Limit
-'^'kRKS: Non-cancelable, without 30 days prior written notice,except for non-payment of premium which will be
.v u
a 1i..0 day written notice.
Lissette Pacheco as Qualifier,License#CCC1328657
This certificate is issued as a matter of information only,is not a policy and of itself does not afford any insurance.
N5 othing contalned In this certificate shall be constructed as extending coverage not afforded by the pollcy(les)shown
r a5 affording insurance to any insured not named above. This provides coverage for Florida policyholders
110.5 domiciled employees only.
By:
Brett Stlegel,Administrator Debra Guidry, CPCU, U erwriting Manager
FRSA-SIF FRSA-SIF
t
z
i "°" - _
i
_ .__ ___
.__.__.
--_� f
f
I
i
i
I
m
FIRST-CLASS
U.S.POSTAGE +
PAID
"'• MIAMI,FL
PERMIT NO.231
585464-2 THIS IS NOT A BILL-DO NOT PAY
��vv ��II gg RENEWAL
$� ELSSSOL��00FING ENTERPRISE INC STATE#RECEIPT NO. 657610526-6
7570 NW 14 ST
33126 MIAMI
OWB L SOL ROOFING ENTERPRISE INC
seciT,Ig$SfAC ITY BUILDING CONTRACTOR WORKER/S
• THIS IS ONLY A LOCAL 8 II
BUSINESS TAX RECEIPT.IT '
DOES NOT PERMIT THE
HOLDER TO VIOLATE ANY
EXISTING REGULATORY OR
ZONING LAWS of THE DO NOT FORWARD
COUNTY OR CITIES. NOR
DOES EXEMPT THE
HOLDER FROM ANY OTHER
PERMIT OR LICENSE DEL SOL ROOFING ENTERPRISE INC
NOT ARCERTI c now O DANIEL DEL SOL PRES
THE HOLDER'S OUALIFICA. 7570 NW 14 ST
TIONS. MIAMI FL 33126
PAYMENT RECEIVED
MIAMI-DADE COUNTY TAX
COLLECTOR:
07/18/2012
60130000105
000045.00 t„dd,,,IdI,,,Id„d,l,l d,,,„IIL,Iddd,I,,,,ld„11„1d,Id,sd1
SEE OTHER SIDE �
I
' I
' r
STATE OF FLORIDA
DEPARTMENT 'OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395
' 1940 NORTH MONROE STREET °
WS TALLAHASSEE FL-32399--0783
PACHECO, LISSETTE
DEL SOL ROOFING ENTERPRISE INC
2525 W 3 CT
HIALEAH FL 33010
STATE OF FLQRIDA . AC# G .G 4 11,9 1
Congratulations! With this license you become one of the nearly one million DEPARTMENT':pF BUSINESS'AND
Floridians licensed by the Department of Business and Professional Regulation. PROFESSIQVi , 1GULATI0N.. '
Our professionals and businesses range from architects to yacht brokers,from
boxers to barbeque restaurants,and they keep Florida's economy strong. CCC1328657 ✓iS12 110429002
Every day we work to improve the way we do business in order to serve you better.
For information about our services,please log onto www.myfloridalicense.com. CERTIFIED RQ�IFITG CpHTItP,CTgR
There you can find more information about our divisions and the regulations that PACHECO, L-I.S.5 -- E
impact you,subscribe to department newsletters and learn more about the DEL SOL ROOFINd... E 2PRISE INC
Department's initiatives.
Our mission at the Department is: License Efficiently, Regulate Fairly.We
constantly strive to serve you better so that you Can serve your customers. IS CERTIFIED under the provtaioae of.Ch.489 FS
Thank you for doing business in Florida,and congratulations on your new licensel Expiration date, AUG 31', >20.14 L1206130-0765
DETACH HERE
°® -
AC 61614 9 9 STATE OF FLORIDA
DEPARTMENT. OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING BOARD $EQ#L12061300765
LICENSE NBR
06/13/2 Oil]110422--0 02 CCC1328657
The ROOFING .CONTRACTOR
Named below. IS CEit'I"IFIED
Under the provisions of 'Chapter 4'$9 -
Expiration date: AUG 31, 2014
6
t
PACHECO, LISSETT°E -.
DEL SOL
ROOFING ENTERPRISE INC `
2525 W 3 CT'
HIALEAH FL 33010
RICK SCOTT KEN LAWSON
GOVERNOR SECRETARY
DISPLAY AS REQUIRED BY LAW
04/13/2013 11:37 FAX. 3052691108 DELTA INSURANCE UND. 1@001/002
CERTIFICATE OF LIABILITY INSURANCE
0611312013
E IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGIHTS UPON THE CERTIFICATE HOLDER THIS
:'tR6 NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
a TCATE OF INSURANCE DOES NOT CONSTITUTE CONTRACT BETWEEN THE ISSUING INSURER(Sh AUTHORIZED
-3R PRODUCER,AND THE CERTIFICATE HOLDER
c1 Wa cartitk,'ats holder is an ADDITIONAL INSUOU.The poky(in)must be endorsed. If SUBROGATION 19 VMMD,subject to
t"tenne and conditions of the policy.Certain pclkls any Mquire an endoraenNmL A slatement on this cwMcste does not+coder rights to the
Cer ficate holder in Neu of etch ondcraement(s�
PRODUCER NAME: LUIS DE LA LLERA
DELTA INSURANCE UN DERWRITERS,INC. ww"Wt 305-268-1107 Not 305-259.1108
777 N.W.7AVENUE,SUITE 3133 ADOMM. DELTANSUNDWOLCOM
MIAMI,FLORIDA 33128 INSURFR(S)AFFOROINGCOVERAGE NpIC4
INSURERA: SCOTTSDALE INSURANCE COMP ANY 41297
INSURED
INSURER B:
DEL SOL ROOFING ENTERPRISE,INC. INSURER C:
7570 N.W.14 STREET,SUITE 111 INSURER D:
MIAMI.FLORIDA 33128 gJSURER E:
PH 305 228 0218 FAX 305 229 5722 INSURER F:
COVERAGES CERTIFICATE NUMBER: REVISION NUMBER:
"73 CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
"-'A4TH STANDING ANY RECIUOiEMENT.TERM OR CONDITION OFANY CONTRACT OR 07HF-R DOCUMENT WITH RESPECT TO WHICH THIS
!F IFSUED OR MAY PERTAIN,THE INSURANCEAFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
"'TI NS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
pJAJL....r.Ldt t..�
r SCE aJSR 1MVD POLICYNUMBER COATS
EACHOCCURMME $ 110001000.lmrar COMMERCIAL GENE M LMLITY PREMISES TSES(R Ea $
100,000.
axaurepw
CLAIMS-MADE ®OCCUR MED EXP(Any oqa peeaon} $ 5,000.
A CPS1641895 010912012 0810942013 PER80NAL&ADV94AM 6 1,000,000.
GENE-RALAGGREGATE $ 2,000,000.
GERLAGOREGATELIMITAPPLIES PER- PRODUCTS-COMPIOPAGG $ 1,000,000.
POLICY w M n LOC f I S
AUTDIMONLE LUUMM
Ea seal ffi
ANYAUTO BODLYOJJURY(Papammn) $
AUTOS AUTOS BODILY INJURY 0�w uddaM} S
HOrEDAUT08 UT P $AOS
UMBRELLALUI6 OCCUR EACH OCCURRENCE ffi
EXCESS LIAR CLAIMS-MADE AGGREGATE $
RETENTION$ $
a` I ATi1
YIN ER
❑N IA EL EACH ACCIDENT $
E.LDWEASE-EAEMPLOYEE S
u OF OPERATIONS balm E.L.DISEASE-POLICY LUT $
DESiRWT1ON OF OPERAIONS 1 LOCA71ON8 J VEaCLES~ACORDICIAddMmdROntwftadmduletfmmopambrequhudI
ROOFING CONTRACTORS LICENSE NUMBER CC C1328857.
CERTIFICATE HOLDER CANCELLATION
SHOLUM ANY OF THE ABOVE DESCRIBED POUCMS BE CANCELLED BEFORE
MIAM(SHORES VLLAGE 1 BUILDING DEPT. THE EXPIRATION DATE THEREOF,NOTICE WILL 68 DELIVERED N
?nd AVENUE ACCORDANCE VAN THE POLICY PROVISIONS.
,F133138
VS 2204 FAX 305 756 8972 AUTHORIZED IREPRESEN'r1ENE
LUIS DE LA LLERA
ztJ(2010406) ®44088-YO'IB AcoRD CORPORATION. All dabhJ I feserved.
The AOORD name and logo are registered marks of ACORD
f
High VeioWty t virrlcae Zone Uniform Pennit
�ars`s c�`+c�PC
liebon
Form
COU14 Y at ILMNO DPi Nfi�TP2W PLr TIQN
Irk
Section A(GenerW Inforatioi)
Muster Porn*No. Process-No.
ConvactWe Job Addy :.
—Del 4946S COPY
Roof Catego"
Low Slope L Mechanically Fastened Tile Mo /Adhesive Set TUe
t, a:.
Asphaltic Shingles »e Metal Panel/Shingfes t._ Wood Shingles/Shakes
�.`, prescriptive 4t1F2-RAS 15D _ Other; q „Q
1 Roof Type
Q O _$ New Roof �_. Re-Rooting C! Recovering ED Repair 0 Maintenance
p � w g ,
We ture Gas Vent Stacks located on the roof? EJ Yes - No If yos,what type? Fi Natural '` j LPGX
W
a Roof Sysb&t inforrnafion
> �t ❑
L4 S4 oof areo(tt a} Steep SSrloped area(%X). Total(ft.�)
u +Seewn i3 LROof Kffi
E A lava and seclionss.rooftral".scwpels.ow� and ova*W ilu tnt*tda d1rnensk=.
Co
of W rlae -Piientl dittat�fonso€eld piureez�tirit9 tottirl ofpa €pats.
s® ire Corner S&a(a'x a').
W t
'4 k
.. ,.
a._� s ,t.,,,{'
a., ' c t ; as t_.�
a
i J 6...a .........4 e 6
Ij
Ole
44 A
t
! i
age
TarCO EUy SYAOM Pengit Package Over Wood Doo..
z t
1 Nam!-Dade County Sulidin5 Dspwfto.nt Sleamnfc ApplIcation
High Velocity fjurrlcane Zone Roofing PermItkliplicaflon Form
"$3e ri rcrrPrr �vice rrerta a• s<rsrg ¢imp Section C page(LOW Slope Roof Systems)
FN to am speafic rood zwemwy componfam ff a awwwMa is rte raqaln4 We"not fn/8)in the text box.
Tarco Top PV-
ROOF ...
SYSTEM NUFAC:'f`RER: l eBkBafTiGr 1r85ySt1Ck Pltit3 FA
Product Approval (NOA;): 07-0917.45 Sy't=TyPe4L_J Top Pty Fastening/Bandlii Matei�al
Wind Uplift Pressures,From RAS'628 or Scaled Calculattons: Self AdhedD9
(Pi) Field:,-45.3 py{ Surfacing: NIA
SIN43LE PLY MWBRANE:
(P2) Perimeters: ^S2 7 psi Single Pty Manufactursr/Type:
(P3)comers: ^i24.4 psf NR
Maximum Design Pressure From NOA: -6D psi c N/A Snge y e® Nfh f1 1V "
Roof Slope: .ail ":12 floor Mean Haight 15 fZ No.of Single Ply 112 sheets:El
Parapet Walls:. No 0 Yes Parapet well Height ft. Single Ply Membrane Fastening/Bonding Material:
NIA
Deco Type: —61$"Piyw6od. 0 FASTENER SPACING FOR BASESHMT ATTACHMENT
Support Spa:'�PN14
"o/c CE SINGLE PLY MEMR018 ATTAC HM
Alternate Depe 1.Field:El°o/eCif Laps•&L ....__ rows "Ole
Existing Roof:
N/A 2.Perimeter.El"oto Q Laps&El rows k.:.__.t"o/c
Fire.Barrier. '3.Comte: "o/o 0,Laps&El. i rows El"o/c
N/A
P,
Vapor Barrier. UMBER OF FASTENERS,PER INSULATION BOARD,
_N/A 1. Field, 2."Peftety.E 3. Corner: NIA
Anchor Sheet
Insulation Fastener Type:
WA NtA
Anchor Sheet Fastener/,Bonding Materlai
wA WOOD NAII TYPE AND SIZE:
Insulation Base 1..ayer Size&Thickness; N//fi
N/A Woad Nailer Fastener Type and Spacing:
Insulation Base Layer Fastener/Bonding Material: let/A
NIA EDGE&COPING METAL Std:
Insulation Top Layer Size&Thickness: Edge Metal Matetial: w4Gaivartlzed Metal—
Edge Size: -3u facie 26 ga.—
Insulation Top Layer fastener i Bonding Materaal: Hoak Strip Size: — IEfAt.EDGE WQQK STRIJ?wA-
N/A _
Edge Metal:Attechment
Base Sheet(s)&.No,of Fiy(s): �f"Q/C Staggered_Spacing v y
G 2 (1 Ply)fciilowed by LeekBarder Eas YLay T
{ Pry) PARAPET COPING METAL NtA
Base.Sheet F85ietier/Bonding MatedaL' Coping Material- —
--
12 gauge 1 i/4"R.S n�ls�rc+ittl. 2.gaixge 1.W tin caps CopingStze: ;—COPING META,WS NIA—
Pty Shest(a)&No.of Ply(s}: »kCUPING M&_AL WQOf<STf21P N/A—
Hook Strip Size:
E egkBarrler EaN Base FIR(1 ply) x Parapet C:oping'MstalAtfeahrYrent
Ply Sheet Fastener f Bonding Material•
5r31f.Adhering
To=9A Detail
t t
Tt115 ASSeXLY CAN BE INSTALLED ON A ti00F D"WITH A MA)SIU M SLOPE OF,5192
opdomd tie-III to
Cap She�at< ply of Slol"d Roof Assembly
EasvStick Plus setf-adharad
Ply,Skeet:t ply of
EasyBase setf-adhered
Elm ME'RAL
WOOD BECK
1 Approved G-2 (91ass) Base-sbe.etr followed Iry
1 14y of Lea.kBatrlerO Easy Lay' Base Sheet.
both layers sitrtultarteously.attached together to the wood
clock. Notes:soe UL listing A.13228
Roof Mean Height: 15'
Roof Slope: LEO 2"
Drip Edge:
_
[F(37-1 W Gauge Galvanized
Surfacing:
Membrane(Tag Fly):
Lea Barrier EWs fldt Pius.FR SelfAdhered
inter.ply shoot
LeakBawer EasySase FR SOAdhered
Easo Sheet:
'G-2 Giass Base fofiowed-by LeakBerrier Easy"y _
Deck Type:
Plywood 50 "
i
Ownees`Notificarion Form HVHZ 2010
Ir
t MIAMh�ADE
0
0
"Delivering Excellence Every Day" SECTION 1524
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of this section. The provisions of
Chapter 15 of the Florida Building Code,Building govern the minimum requirements and standards of the
industry for roofing system installations. Additionally,the following items should be addressed as part of the
agreement between the owner and the contractor. The owner's initial in the designated space indicates that the
item has been explained.
1.Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane
Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion
performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions.
Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed
as part of the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida
Building Code. (The roof deck is usually concealed prior to removing the existing roof system).
Vts3. Common roofs: Common roofs are those which have no visible delineation between neighboring
e. townhouses, condominiums, etc.). In buildings with common roofs,the roofing contractor and/or
.owner should notify the occupants of adjacent units of roofing work to be performed.
4.Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be
viewed from below. The owner may wish to maintain the architectural appearance; therefore,roofing nail
penetrations of the underside of the decking may not be acceptable. The owner provides the option of
maintaining this appearance.
w 5. Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural
distress and may require the review of a professional structural engineer. Ponding may shorten the life
expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
ro&f system is removed. Ponding conditions should be corrected.
6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance
with the requirements of Chapter 15 and 16 herein and the Florida Building Code,Plumbing.
• 7.Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. Exception: Attic spaces, designed by a Florida-licensed engineer or registered architect to eliminate
the attic venting, venting shall not be equjred.
Owner's/Agent's Signature: Date:
Contractor's Signature: Permit Number:
Property Address: A ,
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
e
Florida Building Code Edition 2010
■
High-Velocity Hurricane Zone Uniform Permit Application Form.
Section D (Steep Sloped Roof System)
c Roof System Manufacturer:
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations}:
P2: 4
1: P3■
c
steep Sloped Roof System Description
Deck Type:
Type Underlayment:
Roof Slope:
3 12 Insulation:
Fire Barrier:
■
P
Ridge Venttila�jOq Fastener Type&Spacing: >
JJ�� l _
:
Adhesive Type: ,
—� Type Cap Sheet:"
■ Mean Roof Height:
: Roof Covering:
■ Type&Size
■ Drip Edge:
OF
■
15.36 2010 FLORIDA BUILDING CODE—BUILDING
r ,
O i
A O
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
I
i
Section E (Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values
for M,with the values from Mr.If the M,values are greater than or equal to the M,
values,for each area of the roof,then the tile attachment method is acceptable.
Method "Moment Based Tile Calculations Per RAS 127"
(P,:3�� x A = 1'1 loa-Mg: .pZ=M,,5� Product Approval M, 40/11A
(P2: ►>D.( x M2119?-= .27 _Mg:�=Mr2 . Product Approval M,_�
(P,A.3e x A� ��y?'_ �-M :5'.�2=M 2-Y.0 Product Approval M
Vrre� �'1� g Mrs pP r�
i
Method 2 "Simplified Tile Calculation Per Table Below"
Required Moment of Resistance(M,)From Table Below Product Approval M,
M Re uired Moment Resistance*
Mean Roof Height--1
Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 j 32.2 34.4 36.0 37.4 39.8
4:12 I 30.4 32.2 33.8 35.1 37.3
5:12 1 28.4 30.1 31.6 32.8 34.9
6:12 26.4 28.0 29.4 30.5 32.4
7:12 24.4 25.9 27.1 28.2 30.0
*Must be used in conjunctidn with a list of moment based tile systems endorsed by the
Broward County Board of Rules and Appeals.
For Uplift based the sys hems use Method 3.Compare the values for F'with the values for
F,.If the F'values are greater than or equal to the F,values,for each area of the roof,then
the tile attachment method is acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 127"
(P,:_x 1:_= xj w:=_)-W:_x cos 0: =Fl_ Product Approval F'
(P2:_x 1:_= xi w:=_)-W:x cos 0: - =Fn Product Approval F'
(P,:_x 1:- x w:=_)-W:_x cos 0 F„_ Product Approval F'
Where to Obtain Information
Description ; Symbol Where to find
Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 8 Job Site
Aerodynamic Multiplier d Product Approval
Restoring Moment due to Gravity M. Product Approval
Attachment Resistance M, Product Approval
Required Moment Resistance M. Calculated
Minimum Attachment Resistance F Product Approval
Required Uplift Resistance F, Calculated
Average Tile Weight W Product Approval
Tile Dimensions I°length Product Approval
w n width
All calculations must be submitted to the Building Official at the time of permit application.
P
o ,
6W A .: M�MyJ7y[i�7Myfp�!COtit��•!}lpi 7.pE�'d).*r%�JLR\.pS'd�.�+'A.
nLMZ C;C0DE CONi MANCE OFFICE(ACCO) 140WESTFUGUR'STMW,SMTE
PRODUCT CONTROL•DIMION I&W.- ,Fi O"A",33130-1561
(305.)375-2901 FAX(30'5)375-2908
NOTICZ OF
Tares.
One Information Way
Suite 225
Little Rock,AR 72M
SCOPE:
This NOA is being issued under the applicable.rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Mardi-Dade County Product Control
Division and accented by the Board o€.hales and Appeals(BORA)to be used in Miami Dade County and
other areas where allowed by the Authority Having Jurisdiction(AHT).
This NOS,shall not be valid after the expiration date stated.below.The Miami-Dade County Product
Control Division (In l+/liaml Dade County) and/or.the AX (n areas other thau.Irma Dade County)
reserve the right to have this product or awerial tested for quality assurance puxpoem if this product or
material fails to padbrut in the accepted manner,the manufacturer will inctn°the expense of sacb testing
and the AH1 may inunediately revoke,modify. or suspenel tho-use of such product or matedd within
thekjui stlic&mo BO reserves.the tight to revoke th s.acceptane,If it is determined by Ise -Dade
County ftoduct Control Division that this product or tnaWial faUs to meet the xouiremeuts of the
applicable building code.
This product is approved as described he�rresit6 aad has been dmigned to comply with.ft Morlda.Building
Code and the'Mgh Velocity Harricane Zone ofd FIorida•I fts Code.
DBSCWMON:Tam Sew AdheringModZed ZtuiamRoo&gSyaem overw od
LARMMG:Each unit shall bear a p m+a+t label with the m uWtards name or logo,city, state,
and following statement: "Nam-Dade County Product col Approved",•unless odiaa wise noted
herein.
1MWAL of tbls NGA.shall be considwed after a renewal application has berme -filed and there has
been no change m the Applicable building code negadvely affecting the performance of this product.
TERKNW ION of this NOA will occur after the expiration date or if there has been a revision or
change 13L the:materials,use, and/or manufacture of the product or gruoess.WAsuse of this NOA as=
endorsement of my product, for sales, advalising.or any oar�rcpases sWH automaticaMy
this NOA.Failure to cony witl:aay aeWoa of this NOA shall because for temnnation and removal of
NOA.
ADVERTISE WENT: The.NOA number precede by the words Nami.Dada County,Florida, and
followed by the expiration..date may be displayed in advertising.literature, if any portion of the NOA is
displayed,then it shall be done in its.entirety.
INSPl?CW0N.,A copy of this antire NOA shall*be provided:to.the user by the manufacturer or its
distributors and shall be available far'inspection at the job site at the kegyest of the Building.Official.
This NOA consists o€.pages l through?,
The submitted documentation was reviewed by Jorge L,A lxixi
NOA No.:07-0917.05
5 ration Date-.lJA8,n2
Approval Dates 11/08M
Page.I of 7
JUN-13-2013 15:05 From:DEL SOL ROOFING ENT 3052295722 To:1 800 685 7530 P.6
ROOFING SYSUM APPROVAL
rate orv: Roofing
Su tesorv: Modified Bitumen
ateiial: SBS
Deck�'Te Wood
Maxiainm Desicn LIKessurc -60.0 pat
=Q gilicution: See General Limitation#1
TRAb E NAMES OF PROs CTS MANUFACTURED OA LABELED BY APPLICANT:
TAaus.:1
Test Product
Product Dlm�ons Specification Description
BRSYLRY Tx 133'4' rolls ASTM D 226 Mechanically attached,asphalt coated
Type 1I polyester base sheet.
EasyBasc 3' x 72'rolls ASTM D 6163 Self adhered,t1berglass reinforced,smooth
surfaced.SI3S modified bitumen base ply
membrane.
Easystick Plus 3' x 36'ills ASTM D 6164 Self adhered,polyester reinforced,gmnule
surfaced.SBS modified bitumen cap ply
membrane,
APPliom)INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
Socarcke (With Current NOA)
Gypsum board USG
Polyisbcyanuraw Polyisocyanuraate insWation board Crenerie
Expanded&Extruded Polystyrehc Polystyrene roof board insulation Generic
Wood Fiber Wood fiber insulation board G oneric
high Density WOW Fiberboard Wont f ber insulation board Generic
Perlite!Insulation Perlitc insulation board Generic
I •
i
NOA No.:07-0917.05
°!Y Expiration Date:ILVM2
Approval Date:11/08/07
Paige 2 of 7
JUN-13-2013 15:05 From:DEL SOL ROOFING ENT 3052295722 To:1 600 685 7530 P.7
i
APPROVED FASTENERS;
TABLE 3
Fastc6cr Product Product Manufacturer
Number Name Description Dimensions (With Curren!NOA)
1.; 0MG#l2,#14 Hea hoofing,and insulation OMG,Inc.
Duty Fasteners fasteners,with#3 Phillips
head.
2. OMG 3 in.Galvalume Galvalume steel stress plates. 3"round OMG,Inc.
Steel Plates
3.` Tru Fast DP bsulation fastener for wood, The Tru-Fast Corp.
steel•and concrete
4.: Tru Fast I:ID Insulation fastener for wcx)d, The Tra Fast Corp.
steel and concrete
5.' Thi Fast MP-3 Galvalume steel stress plate 3"round The Tru-Fast Corp.
EVIDENCE SUBMITTED:
z=t Aseney 'rent Identifier Teri.Nume/Rettorl, pate
Exterlor Research& T6460.06.07 TAS 114(3) (W26/07
Design,LLC T6470.08.07-R) ASTM D6163&D6164 09/05/07
NOA No.:07-0917.05
K;K Expiration Aatc:11AH/12
Approval Datet 11/08/07
Page 3 of 7
JUN-13-2013 15:05 From:DEL SOL ROOFING ENT 3052295722 To:1 800 685 7530 P.8
APM, OWD ASSEMIJU
Membrane Type; SBS
DeckTy'ps 1I: Wood,Insulated
Deck Description: "'132"qr greater plywood or wood plank
$yslem'fype C; All layers of insulation tu-e mechanically attached to roof deck.
All General and System L- bons sppIy.
One or more layers of the folio ing:
"Insulation Layer:(opt! sal) Insulation Fasteners Fastener
Any Approver]I'olyisocyanu te,EPS,Wood Fiberboard (Table 3) Densitp/ft2
MuTtimum 2"thick N/A N/A
Top In.+alation Layer Insulation Vaatenerq Fastener
Secniock® (fable 3) Density/fe
Minimum 3/8"thick 1,.3,4 1:1 i1tZ
Note: Ba$g layers of insulatid n shall be mechanically attached using the fastener density listed.ne
iusalittion panels listed are m nimum W-us and dimensions;if larger panels are Bused,the number of
fasters shall be increased maintaining the seine fastener density. Please refer to.hoofing
Application Standard RA,S 1 7 for insulation attuchmeaL
Base;Sheet. ono gly of EasyBase self-adhered.
ply Sheet (OpdotIal)One ply of Buyllase self-adhered.
Cap Sheet: One pl;of EasyStiek Plus self-adhered.
Surfacing: (Option) install one of the following to obtain required fire clalWfication.
L Gravel or slag at 400lbs/sq or 300 th,Jsq,respectively,in a flood coat of
appro�ed asphalt at 60 thslsq.
2. Karns 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos tree
Aluminum Roof Coating ai 1'/z gal/sq.
3. Kok696 Products,Sunguard Acrylic Roof Coating at 1 gal/sq.
4. Mon sy Frndurc Aluminum Roof Coating.Weather Check or l"m4 i ude
Alum3Itum Roof Coating at I,j gallsq.
5. Grund al NN Aluminum Roof Coating at 1-2 gal/sq.
6. Fields F350 Heat Shield Aluminum Coating or P630 Hear.Shield Fibered
Aluminum Coating at 1Y2 X11141.
Maximum Design -52.5 psf(Sea General:Limimion#7)
Pressure:
i
NOA No.,07-0917:05
Expiration Date;11/08/12
Approval Date:71/08/07
Page 4 of 7
JUN-13-2013 15:06 From:DEL SOL ROOFING ENT 3052295722 To:1 600 685 7530 P.9
i
hie=' rune Type: SBS
DeclJ Type lit Wood Iusulatcd
Deck!Descriptions "/32"i greater,plywood or wood plank
System Type D: All 1-.1 s of insulation and hatic sheet%imultaneously attached.
All General and System Limitations apply.
One r more layers of the folly ving:
DamXnsulation Layer:(Opts aal) Insulation Fasteners Fastener
Any Approved PolYisocyanui ate,EPS,Wood Fiberboard (Table 3) Density/fe
Maximum 2"thick N/A N/A
Top j"Sulation Layer insulation'fasteners Fastener
Secuiv" (Table 3) Density/fe
Minlinum 3/$"thick N/A N/A
Base Sheet: One or more plies of Easyl ay,mechanically all tthed 10"o c, in the min.4" lap
and I 04.in two,equally spaced,staggered center rows with OMO#12 Heavy
Duty fasteners with OMG 3 in.Galvalume Steel.
Ply sheet: One pl i of Fasyj3ase self-adhered.
Cap Sheet: One ply of F.asyStick Pitts so]f-adhert d.
Surfacing.- (pp6011.1) Install one of the following to obtain required fire classification.
1. Grave I or slag at 400 lbs/sq or 300 lbs/sq,respectively,in a flood coat of
approved asphalt at 60 lbs/sq.
2. ,Karnak 97 Fibrmted Aluminum Asphalt Roof Coating or Asbestos Free
Mule um Roof Coating at 11/2 gal/sq.
3. Kokc Products Sunguard Acrylic Roof Coating at 1 gal/sq.
4. Mons y Endure Aluminum Roof Coating,Weather Check or Pro-Grade
Alu4um Roof Coating at is/z gal/sq.
5. Gran sl M13;Aluminum Roof Coating at 1-2 gaUsq.
6. Fields F35014eat Shield Aluminum Coating or F630 Heat Shield I?ibered
Alu um Coating at 1%gal/sq.
Maxi&um Design -60.0 p f(Sce Cenral Limitation#7)
Press»re:
NOA No.:07-0917.05
a c,� lxpiratlon Dates 11!08112
Approval Date:1-110M
' 'P'age S of 7
Deek.Type., Wood,Non-insulated
Deck Dewxiptient: 'IV or greater plywod or wood plank
System Type E: Bm saw mechanically€astened.
All Generaland.System:Uimtations apply.
Base Sheet: One ply of LeakRarxim*Easylaylu EF`P'Asphalt Sawn aced Underi aymennt
fastened to the deck as desczil3ed bedow:
Fastening#l: Attach base sheet:using 12 ga.annular ring shank nab with min.32 ga., I-51r
diamter tin-caps spaced T'o.c.in tbo €"la R nand T o.c..in three eq�ualBual�s��aced
gd,,. nter rows.
Fastening#2: Attach base sheet using OMG#12 cc l avy.Duty fasteners with.OMG 3 in.
Galvalume Steel Plate or Tha t DP or N>fasteners with TruFast.U1F-3 plates
spaced lily'o.c.in the min.4'lap and 10"mc.in two,equaUy spate,staggered
center rMs
Ply S4.eet: £3ne piy of EwRase se if: emd.
cap Sheet: One ply of HasyStick Plus.self adhered.
Surfacing: (Optional) kastall erne of die fc km ing.to obtain.required fire classifi=tim.
1, Gravel or slag at 40{}UWsq or 3001,bsfs%re specti'vely,in a f wd coat of
ap proved asphalt at 60 ibs/sq.
2. Karnak 97 Fibrated Alummurn Aspbalt RpO Coating,or Asbestos Free
Altuninum Roof Coadeg at 1%gallsq
3. Kok=Prod"Sxmpard Acrylic R10acoating at i gal sq.
4. Mmmy End=Ahuumum.Roof Cog,Weather Check or Pro-Grade
AlumW=Roof Ca ng at MgaVaq.
5. Grundy aiNB E lu Rwfbotlqg.st t Z,pUsq.
6. Fetes MO Beat Shield Aluomm Coatsag or F630 Nzat Shuehl,Fibored
Coadn€g at 14A gal/9%
umDesign -6.0.41nsf General Moats►);
Pressure:
l•1OA No--t17 d7AS
Luplraiiem.Data:d11�8f1.2:
Approval Date.I1/MO7
Page 6 of 7
e ,
0
WOOD D1 SYSTEM L MffAnONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a tnechanicatty fastened base or anchor
shy.
GENERAL TrD&TA.`7 j mst
1. Fore classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation'may be installed in multiple.layers. The first layer shall be anached in compliance with
Product Control Approval gmddmes All other layers shard be adhered in a full mopping of approved
asphalt applied within the EW range and at a rate of 20-40 lbs./q,or mochartioally attached using
the fastening pattern o£the top layer
I All standard panel sizes are acceptable for mechanical attachment When applied in approved asphalt,
panel size shall be 4'x 4'maximunL
4. An overlay and/or recovery board insulation panel is.required orb.all applications over closed cell
foam insulations wbw the base sheet is fully mopped. if no recovery board is used the base sheet
shall be applied using,spot mopping with approved asphalt, 12" diameter Wiles,24" o c.;or strip
mopped 8"ribbons in three roves,one tat each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling-of the strips is.not acceptable. A.6" break shall be
placed every IT in each ribbon to allow cross ventilation. Asphalt applic4on of either systems:shall
be at a minbraim raze of 12 Abs./sq.
Note: Spot attached systexras.shaR be Ibnited.to a mwftrjM&sjp pressnre of-45 ps£
5. Fastener spacing for is advion attachment.is based.on a.Minimum Chtaractte"e Force(F)value of
275 Ib£,as tested in compliaum with<Tes&g AppSlication.Standard TAS 115. ff the fastener value,
as'/'held-tested,are below 275 lbf.insulation attachment shaH'not be acceptable.
6. Fastener spacing for mechanical attachment of anchodbase sheet ar membraw attachment is based
on.a mWmurn fastener resistance value in c*uncdon.wi&tome.maximan design value listed wltlt%n
a specific system. Should the fasteter resistance be less tiara that required, as determined by the
Building Official, a.revised fastener spacing, prepared. signed and sealed by a Florida Registered
hgiaoeer,Architect,or Registered Roof Consultant my be subnjtmd. Said revised fasters spacing
shall-utilize the withdrawal resistance valve taken from Testes AppUcation Stndards TAS 105'ated
calculations in corrPliance with Roofing AppUcation Standard RAS 117,
7. Perimeter'and corner areas shall comply wifh the enh anoced. uplift presklu re requirements of these
areas. Fastener densities shall be increased for both..insulation, and base sheet as.calculated in
compliance with Roofing Application Standard RAS IM Ca)culations prepared,signed and.sealed
by a Florida eistr Professional..Eugiaer, le gd tesed 1#0hec4 or Roglstmd Roof Consultant
(When Ws limiltadw 3s speciffimtly r erred WItIft this NO*.Oeneral LADUation#9 WM not be
apps}
8. Al attachment and sizing of peAr .ater nailers,metal profile,and/or flashing termination designs shall
conform to R000 ng Application Standard PM 111 and applicable wind load arecl}ih=ents.
4. "he matron designed:Pressure limitation;listed shall be cable to all rood
pressure zones(i.e,
field, peruheters, and corners). Neither radional an*314, nor.P-Xtragoladon shall be permitted for
enhanced fastening at enhanced pressum zones (Le. permotcM extended corners and comers).
Mext this limitation is specif M4 xefe Ted witWu this NOA,General lAdtation#7 WM loot be
applicable.)
END OF THIS ACCEPTANCE
1+SOA No..4l'l«4) l7.tD5
`�-� Expbratttiau Dam; {}�/l�
Apparuval Date:,11/08/07
Pap7Qf 7
TGFU.R13228
Roofing Systems
TARCO OF TEXAS INC 813228
2403 TAYLOR VALLEY RI?
BELTON,TX 76515 USA
Asphalt organic felt for use in construction of Class A,B and C roofing systenns.
Asphalt glass fiber felt for use in construction of Class A,B and C roofing systems.
SINGLE PLY 1WE&fBMNR SYSTEMS
Class A-Futiy Adhered
1.beck:C-15/32 Liedue: .1/2
Base Sheet:—One ornnore lies of any Ul,Classified G2 or"LeakBarrier G1assBase",followed by,
"LeakBanrier SBS IulukiPt"ose I7nderlayment"or'I akBarr eer Eas F,a " ndechanicall attached.
Pl Sheet:--`LeakBarrier Las yBase FR",self adhered one or-xnore lies.
Membrane:—"LasyStick Plus FR",self adhered.
o �n°`agl . ?2.010 Llnde. vriters l.abiratoriesac c
The appearance of companny's. ar prod t in this database does not in itself assure that,products
so identified have been mapufactured.under UL's Follow-Up SerVice.Only those products bearing the
UL Marls should be considered to be1isted and covered antler UL's Follow Up Service.Always look
for tho Marls:on the product.
UL permits the reproduction of the-material cotntainod in.d a Online Certification Directory subject to
the following conditions. 1.The Guide Informationn,Designs and/or I;Wngs(files)roust be.pmented in.
their entirety and in a non.-misleading.manner,without arny.nianipulation ofthe data(or at wings).2.
The statement "Reprintted from the Online Certifications Directory with permission:from Underwriters
Laboratorles.Iric.".,iust appear.adjacent to the.extiraacted material..la.addition,.thie reprinted material
must-include a copyright.natice in the following format !'Cop)Tight 0 2010 Underwriters Laboratories
Inc.®"
nn i ;0eg an as-t 0 T U 6 tsi 1{5€irrp vst=!fit ng ta± o '14 t0 4 V I a e'k5itn nod *MS tii9�� l
t' -"Ian
i m
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
- -- - T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) vrww.mlamidade.eov/uera
Santafe Tile Corporation
8825 NW 95o'Street
Medley,FL 33178
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Santafe Spanish `S' Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This replaces NOA# 10-1005.15 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0210.01
MuutHODfwecoutv7Y Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 1 of 5
a m
ROOFING ASSEMBLY APPROVAL
Cateaory• Roofing
- Sub-Cateaory: Roofing Tiles
Material: Clay
Deck Type: Wood
1. SCOPE
This approves a roofing system using Santa Fe"Santafe `S"Clay Roof Tile,as manufactured by Ladrillera
Santafe S.A.in Bogota,Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this
Notice of Acceptance. For locations where the pressure requirements,as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the
values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Santafe`S' Clay Roof L= 18" TAS 112 One piece high profile clay roof tile equipped with
Tile W= 11.1" two nail holes. For nail-on,mortar set and adhesive
set applications.
Trim Pieces I=varies TAS 112 Accessory trim,clay roof pieces for use at hips,
w=varies rakes,ridges and valley terminations. Manufactured
varying thickness for each tile profile.
2.1 MANUFACTURING LOCATION
1. Bogota,Colombia
2.2 SUBMITTED EVIDENCE
Test Agency Test Identifier Test Name/Report Date
The Center for Applied Engineering,Inc. 94-156-8 TAS 101 Aug. 1994
94-156-9 TAS 102
The Center for Applied Engineering,Inc. 25-7205-1 TAS 101 March 1995
The Center for Applied Engineering,Inc. Project: 07-07-00-91 TAS 100 Sept. 1994
(307023)
Redland Technologies 7161-03 TAS 108 Dec. 1991
Appendix II (Nail-On)
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102 &TAS 102(A)
Redland Technologies P 0402 Withdrawal Resistance Sept. 1993
Testing of Screw vs smooth
shank nails
NOA No.: 12-0210.01
MIAM10ADECOUNW Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 2 of 5
0 0
2.2 SUBMITTED EVIDENCE
Test Agency Test Identifier Test Name/Report Date
Redland Tech_no_logies P 0647-01 TAS 108 Aug. 1994
(Mortar Set)
Redland Technologies P 0631-01 PA 108 July. 1994
(Mortar Set)
Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999
IBA Consultants,Inc. 2353-4 Restoring Moment Aug. 1999
PRI Asphalt Technologies,Inc. SFTC-003-02-01 TAS 101 12/06/02
IBA Consultants,Inc. 2353-70 TAS 101 09/22/03
IBA Consultants,Inc. 2353-71 TAS 101 09/22/03
IBA Consultants,Inc. 2353-93 ASTM C 1167 07/18/05
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard
RAS 118,RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight-W(Ibi) Length-1 (ft) Width-w (ft)
Santafe'S' 1 6.7 1.5 0.958
NOA No.: 12-0210.01
MIAMIDADECOUNTY Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 3 of 5
Table 2: Aerodynamic Multiplyers—%(ft )
Tile X(ft ) X (ft)
Profile Batten Application Dir
Santafe'S' 0.274 4 0.297
Table 3: Restoring Moments due to Gravity-M9 (ft-lbf)
Tile 2":12" 3":12" 4":12" 5":12" 6 10:12" 7':12" or
Profile are ster
Battens Direct Battens I Direct Battens Direct Battens Direct Battens Direct Battens Direct
Deck Deck Deck Deck Deck
Santafe'S' 5.93 5.90 5.:85j 5.8V 5.73 5.69 5.56 5.53 5.32 5.29 5.03 1 5.00
Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Nail-On Systems
Tile Profile Fastener Type Direct Deck Battens
Santafe'S' 2-10d Ring Shank Nails 21.8 N/A
One#8 Screw 29.16 N/A
Two#8 Screws 38.28 N/A
One#8 Screw w/Clip 57.31 N/A
Two#8 Screws w/Clip 57.60 61.77
1. Approved screws as noted'Product manufactured by others'.
2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Santafe'S' Tile Bond 38.9
Polyfoam Polypro AH 160Tm 28.5
2 See manufactures component approval for installation requirements.
3 Flexible Product, Inc.Average weight per patty 10.4 grams.
4 Polyfoam Product,Inc.Average weight per patty 9.4 grams.
Table 5A: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Santafe'S' Polyfoam Polypro AH 160Tm
Pol oam Pol ro AH 160T"" 61.9
5 Paddy Placement of 63 rams of Pol ro AH 160Tm.
6 Paddy placement of 24 grams of Polypro AH 160Tm.
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mortar or Adhesive Set Systems
Tile Tile Attachment
Profile Application Resistance
Santafe'S' Mortar Set 23.6
NOA No.: 12-0210.01
Mu+rfiOaoecounrnr Expiration Date: 02/01/16
Approval Date: 05/31112
Page 4 of 5
D
a m
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement: "Miami-Dade County Product Control Approved".
SANTA FE TM MADE IN COLOMBIA
LABEL FOR SANTA FE SPANISH"S"CLAY ROOF TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWING
When using one screw
use this hole.
18"
O
11.1"
"SANTAFE S" CLAY ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 12-0210.01
htLAr►HDAVecoutvrr Expiration Date: 02/01/16
Approval Date: 05/31/12
Page 5 of 5
M I A M I•DADE MIAMI-DADE COUNTY,FLORIDA
mow METRO-DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE(BCCO) 140 WEST FLAGLER STREET,SUITE 1603
PRODUCT CONTROL DIVISION MIAMI,FLORIDA 33130-1563
(305)375-2901 FAX(305)375-2908
NOTICE OF ACCEPTANCE (NOA)
Tarco
One Information Way
Suite 225
Little Rock,AR 72202
SCOPE
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials.The documentation submitted has been reviewed by Miami-Dade County Product Control Division
and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas
where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Division that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code,including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 30#ASTM Specification Felt,EaSyLayTM,FaSt90TM,PS200,MS300,SS400
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of.
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 08-0229.04 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 08-0804.10
MIAMbDADE UN I,( - Expiration Date: 01/25/12
COTY Approval Date: 10/02/08
Page 1 of 16
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Asphalt,SBS,Polyester
SCOPE:
This acceptance is for 30# ASTM Specification Felt, EasyLay, Fast90, PS200, MS300 and S8400
underlayments as manufactured by Tarco,for use with approved prepared roof assemblies as described in this
Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity
Hurricane Zone of the Florida Building Code.
PRODUCTS DESCRIPTION:
Product Dimensions Test Specification Product Description
30#ASTM 3' x 72"rolls ASTM D 226 Type 11 Asphalt saturated felt underlayment
Specification Felt
EasyLay 3' x 133' 4" ASTM D 226 Type H Sheet material comprising a polyester substrate
rolls coated with bituminous coating for use as an
underlayment in roofing applications. Designed
as a shingle and metal roofing underlayment
and for use in tile roofing assemblies.
Fast90 3' x 36' rolls TAS 103 Granular surfaced, asphalt-impregnated organic
ASTM D 249 felt reinforced, bituminous sheet material with a
ASTM D 6380 self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a tile roofing underlayment.
PS200 3' x 66'8"rolls TAS 103 Film or fabric surfaced, fiberglass reinforced,
ASTM D 1970 SBS modified bituminous sheet material with a
self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a tile and metal underlayment.
MS300 3' x 66'8"rolls ASTM D1970 Fine granular surfaced, fiberglass reinforced,
3' x 33'4"rolls bituminous sheet material with a self-adhesive
bottom layer, for use as an underlayment in
sloped roof assemblies. Designed as an ice and
water shield, and a shingle underlayment.
SS400 3' x 66'8"rolls ASTM D1970 Smooth surfaced, fiberglass reinforced,
3' x 33'4" rolls bituminous sheet material with a self-adhesive
bottom layer, for use as an underlayment in
sloped roof assemblies. Designed as an ice and
water shield, and a shingle and metal roofing
underlayment.
NOA No.: 08-0804.10
MIAMf•DADE UNTY
Expiration Date: 01/25/12
CO
• Approval Date: 10/02/08
Page 2 of 16
Align the next roll over the preceding sheet so as to form a 4"seam, and then fold back the sheet,
exposing the side lap of the first sheet.
Remove any selvage release film,if present,covering the side lap,prior to application.
Install capped or tin tagged nails 6"o.c.in the center of the seam area according to Building Code.
Then install the just placed membrane,per instructions above.
Walk in the field and seam areas to press the sheet in place, as it is applied.
Apply subsequent sheets in the same manner,with 4"side laps and 8"end laps over the preceding
sheets.
Apply full roll width,a 1/16"thick uniform layer of asphalt plastic cement to the surface of the first
course in the 8"end lap area before adhering the next course.
Apply 1/16"thick uniform layer of asphalt plastic cement wherever the self-adhesive compound comes
in direct contact with granular surface.
Stagger the end laps a minimum of 36" (3')from the preceding course.
Roll or broom the entire Fast90 surface so as to have 100%contact with the substrate,giving special
attention to the overlap areas.
Fast90 shall be applied to protrusions, slope changes, valleys,curbs, and other roof top penetrations
before any other sections of the roof.
When applying Fast90 in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in each direction.
For ridge applications,center Fast90 and roll from the center outward in both directions.
Place Fast90 over any metal drip edge in accordance with RAS 111.
Prime all metal collars,flashing, valleys, liner and drip edge with ASTM D 41 primer.
Flash vent pipes,stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
All protrusions or drains shall be initially taped with a 6" piece of Fast90. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Fast90 shall
be applied over the flashing detail.
8. Vertical strapping of the roof with Fast90 is acceptable.
GENERAL LIMITATIONS—PS200:
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in
compliance with applicable building code.
3. PS200 shall be applied only when material interface(air,deck, membrane)temperatures are 40°F and
rising.
4. PS200 shall not be installed when any form of moisture such as water, dew,rain,etc. is present on the
substrate.
5. PS200 shall be applied to a smooth,clean and dry surface, with the deck free from irregularities.
6. Ensure roof has positive drainage prior to installation of PS200.
7. PS200 shall not be applied over an existing roof membrane.
8. After installation of PS200, wait a minimum of 24 hours before roof loading of tiles.
9. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid
dropping of tile directly on the underlayment.
NOA No.: 08-0804.10
MIAMI•DADE COUNTY
Expiration Date: 01/25/12
• Approval Date: 10/02/08
Page 8 of 16
10. All tiles shall be staged(two tiles perpendicular to slope,four tiles on top parallel to slope)as per
manufacturer's requirements,not to exceed 6-high,to the standard maximum roof pitch of 6:12 for flat
tiles and 6:12 for lugged tiles (See Tile Staging Method below).
At roof slopes greater than the above limitations,PS200 shall be installed behind a nominal 1"x 2"
horizontal batten.
Tile Staging Method
Slopei
Front View -Staged Tiles Side View -Staged Tiles
11. The manufacturer reserves the right to change the the staging method at any time.
12. The manufacturer reserves the right to change the number of tiles stacked,not to exceed 6-high, at any
time.
13. PS200 shall not be left exposed for longer than 120 days after application.
14. The manufacturer reserves the right to change product exposure period at any time; not to exceed the
preceding maximum time limitations.
15. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of PS200
with specific prepared roofing products. PS200 may be used with any approved roof covering Notice of
Acceptance listing PS200 as a component part of an assembly in the Notice of Acceptance.
If PS200 is not listed, a request may be made to the Authority Having Jurisdiction (AHJ)or the Miami-
Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the product,wind uplift resistance, and fire testing results.
16. All products lised herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9B-72 of the Florida Administrative Code.
NOA No.: 08-0804.10
LL COUN
Expiration Date: 01/25/12
MIAM MUTY Approval Date: 10/02/08
Page 9 of 16
L
APPROVED ASSEMBLIES—PS200:
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Deck Type 1: Wood,Non-Insulated.
Deck Description: Minimum 19/32"plywood or wood plank.
Anchor/Base Sheet: One or more plies of ASTM D226 Type II, or ASTM D2626, or EasyLay
underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap,
mechanically fastened to deck.
Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered
rows 12"o.c.in the field(for Anchor/Base sheet only).
Membrane: One ply of PS200 with a minimum 4" wide side lap and a minimum 8" wide end lap,
adhered to the base sheet.
Surfacing: Approved Roof Assemblies.
INSTALLATION REQUIREMENTS—PS200:
1. PS200 shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing
Contractors Associations (NRCA) when installing PS200.
3. During installation, comply with Occupational Safety and Health Administration (OSHA)safety
standards; use common sense measures and adequate safety precautions to prevent accidents.
4. PS200 shall be acceptable for mechanically fastened roof tile and adhered roof tile applications, and
for use with metal roofing assemblies.
5. Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate
thoroughly to remove any dust and debris prior to application.
6. For re-roofing applications,all old roofing and other loose materials must be removed. Do not install
directly on old roof coverings.
7. Cut the PS200 roll to suitable, manageable lengths before installation.
Place a full width piece of the pre-cut PS200 underlayment on the substrate, with the side lap on the up
slope side.
Align PS200 so that it is parallel to the eave(low)edge of the roof, and extend over the eave and rake
approximately 3/8".
Fold back the sheet,and remove the exposed release film,taking care not to displace the sheet.
Working from the center out, roll the sheet onto the substrate,taking care to avoid wrinkles and ridges.
PS200 must be set straight. Repeat this process for the remaining half of the sheet.
Align the next roll over the preceding sheet so as to form a 4"seam, and then fold back the sheet,
exposing the side lap of the first sheet.
Remove any selvage release film,if present,covering the side lap,prior to application.
Then install the just placed membrane,per instructions above.
Apply full roll width, a 1/16"thick uniform layer of asphalt plastic cement to the surface of the first
course in the 8" end lap area before adhering the next course.
Walk in the field and seam areas to press the sheet in place, as it is applied.
NOA No.: 08-0804.10
Expiration Date: 01/25/12
MIAMI•DADECO�NTY Approval Date: 10/02/08
Page 10 of 16
Place SS400 over any metal drip edge in accordance with RAS 111.
Carefully trim the excess material off the eaves and rakes.
Prime all metal collars,flashing, valley liners, and drip edge with ASTM D 41 primer.
Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
All protrusions shall be initially taped with a 6"piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of SS400 shall
be applied over the flashing detail.
Inspect ALL eave edges,rake edges,T-Joints,and end laps to verify that they are securely held in
place. Re-cement where necessary to ensure tight bonding.
8. Vertical strapping of the roof with SS400 is acceptable.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of these materials.
MANUFACTURER'S CONSIDERATIONS:
1. Fast90,PS200,MS300,and SS400 can be directly adhered to wood decks. Ensure that such application
is in compliance with applicable Building Code.
2. For best results when adhering Fast90,PS200, MS300, and SS400 directly to wood deck,surface may be
primed with an ASTM D 41 Primer. When using primer, follow the manufacturer's recommendation for
`cure time' prior to application of Fast90,PS200,MS300, and SS400.
3. When using Fast90 and PS200 in tile roofing applications, use of battens on roof slopes 6'/4:12 and
higher is recommended.
4. Code body requirements supersede manufacturer's recommendations and installation guidelines.
END OF THIS ACCEPTANCE
NOA No.- 08-0804.10
MIAMI•DADE COU Expiration Date: 01/25/12
NTY
Approval Date: 10/02/08
Page 16 of 16
s
MIA .
MEW MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
_._ . . T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.mlamidade.euybera
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN.55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:3MTM 2-Component Foam Roof Tile Adhesive AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0228.18
MIAMMADE OUNTY
Expiration Date:05/10/17
Approval Date:05/10/12
Page 1 of 7
o
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
.. ..Materials: Polyurethane
SCOPE:
This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance.For the locations where the design pressure requirements,as
determined by applicable building code,does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127,for use with approved flat,low,and high profile roof tiles
system using 2-Component Foam Roof Tile Adhesive AH-160.Where the attachment calculations are done as a
moment based system for single patty placement,and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive
Roof Tile Adhesive AH-
160
Foam Dispenser RTF1000 N/A Dispensing Equipment
ProPack®30& 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160
roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Prove Test Results
Density ASTM D 1622 1.61bs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
+6.0%Volume Change @I 58T., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
NOA No.: 12-0228.18
Expiration Date:05/10/17
Mwr► oe Co11 Approval Date:05/10/12
Page 2 of 7
A
• q m
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Agency Test Identifier- Test Name/Reno Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3Mrm 2-Component Foam Roof Tile Adhesive AH-
160 roof file adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their file
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F — W
2
F'=
MS
NOA No.: 12-0228.18
Expiration Date:05/10/17
M�Art�aneCOUt�r�r Approval Date:05/10/12
Page 3 of 7
i A
m
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTm 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance,expressed as an uplift based system,to meet or exceed the uplift resistance determined in
compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the"A"component and the"B"component shall be maintained between 1.0-1.15 (A): 1.0
(B). The dispense timer shall beset to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No
other settings shall be approved.
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or
ProPack®30& 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 2 to 3 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in
accordance with the Placement Details'herein. Each generic tile profile requires the specific placement noted
herein.
Table 1:Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per
Min.(grams) paddy Min.(grams)
Flat,Low High Profiles #1 35 N/A
High Profile 2 Piece Barrel #1 17/side on cap and 34/ an N/A
Flat,Low,High Profiles #2 24 N/A
Flat,Low,High Profiles 1 #3 1 g
i
NOA No.: 12-0228.18
MIAMMADE COUNTY
Expiration Date:05/10/17
MAMMA DE Date:05/10/12
Page 4 of 7
i
t a '
m
LABELING:
All 3MTM 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
Nag through plastic eemeM Paddy Refted Too) Nail through plastic eoment
Paddy(BenesOi Teel
undedeyment Undedaynrert
1 1
101n
to in.
21
Few Em course Fescle
Weepme
Eave emu only: Eave course only: Eve closure
Eaw Clestue Keep adhesive approL Keep adhesive OR= Drip 04e
41n.up from weepholes 4 hL up from weepholes
Nall through plastic cement Paddy(Beneath Tile) 1)Place enough adhesive t0 achieve 17 to 23 onal 2)Ws or ateep pitch
Undedaymem square ftes in contact with tiro pantile BAPpeadClla Nag through plastic cement
2)Turn covers upside down.Place adhesive 112 in.
To 1 in From outside edge of cover die.
Then hrslall the tile. o
undedaymerd
10 In. I o 0
2 in. = j
Eve Coures o � o
Eeve Closure
Remov _ -
Keep aadl lvedappro>t 4tn up Faso oftleam ftming
from weephoies course covertge.
Abut to second couraa of opgoru d
pan dies.Eranne amend of Pohd mortar pan and covertAes are
gush at am On on longitudinal
edges of tge
Eave closure WeepiroIs Fasela
�modarshown)
NOA No.: 12-0228.18
MIAMPDADE COUNTY
Expiration Date:05/10/17
e a Approval Date:05/10/12
Page 5 of 7
i
m m
ADHESIVE PLACEMENT DETAIL Z
SINGLE PATTY
Nail through plastic cement Paddy(Beneath Tile) Nall through plastic cement
Paddy(Beneath Tile)
Underlaymerd °� Undedaymerd
1
a
71n. In. '-
- 71n. ��21n.
Eere Course °
°
Fascia Fascia
Weephole
Eave Course Eave closure
Eave Closure Drip edge
Nail through plastic cement Paddy(Beneath Tile)
Underlayment
71n. ten.
Eave Closure
Eevs Course Fascia
NOA No.: 12-0228.18
Expiration Date:05/10/17
M ��D;Coulm Approval Date:05/10/12
Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Nail through plastic cement Paddy Nall through plastic cement Single paddy under die
(between die) Undedayment Single paddy between file
Paddy 2 In.x 7 Im medium
o
(under tile)
size paddy save
course only
qZ J- 11-N
Single paddy -----
---
Ir 3 In 3 in. under file n.x 3 In.
I
a ......
Single paddy on 2 in. 4 In. Single 4 In. 2 in.
under-
paddyon
layment under-
layment
Single paddy Fascia
Ve course on top of the Weephole
Single paddy In.X 7 In.medium Em closure re
on top of tie size paddy save % Course Em DrIp edge
Fascia course only
Nall through pleadc cement Single paddy
under die Single paddy
between die
lr 3 In.x 3 In. 41n.
Single paddy
an undeflayment 2 n.
Single paddy Eave closure
on top of the 2 In.x 7 In.medium
Ea"Cc sin paddy save course only
size
END OF THIS ACCEPTANCE
NOA No.: 12-0228.18
MILAM•OODE Expiration Date:05/10/17
U
•M'M Approval Date:05/10/12
Page 7 of 7