CC-12-768 (4) ' Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-189468 Permit Number: CC-5-12-768 Scheduled Inspection Date: May 06,2013 Permit Type: Commercial Construction Inspector: Bruhn, Norman Inspection Type: Tie Beam Owner: , BARRY UNIVERSITY Work Classification: Addition Job Address: 11300 NE 2 Avenue Wiegand &Annex Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360010160-09 Project: BARRY UNIVERSITY Contractor: TURNER CONSTRUCTION COMPANY Phone: (786)621-9000 Building Department Comments ADD NEW CHEMICAL STOCK ROOM Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-189231. CREATED AS REINSPECTION FOR INSP-172945. Provide special inspector certification. NB Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. May 06,2013 For Inspections please call: (305)762-4949 Page 26 of 48 t Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-189467 Permit Number: CC-5-12-768 Scheduled Inspection Date: May 06, 2013 Permit Type: Commercial Construction Inspector: Bruhn, Norman Inspection Type: Fill Cells Columns Owner: , BARRY UNIVERSITY Work Classification: Addition Job Address: 11300 NE 2 Avenue Wiegand &Annex Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360010160-09 Project: BARRY UNIVERSITY Contractor: TURNER CONSTRUCTION COMPANY Phone: (786)621-9000 Building Department Comments ADD NEW CHEMICAL STOCK ROOM Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed El CREATED AS REINSPECTION FOR INSP-172942. Provide special inspector certification. NB Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. May 06,2013 For Inspections please call: (305)762-4949 Page 25 of 48 CONSULTING ENGINEERS,INC. .. +.. .h -_.tee c... .� ... <.... ,.. .. ...- _..,._ • 5601 NW 9TH AVENUE,SUITE 401 / FORT LAUDERDALE,FL 33309 STRUCTURAL BUILDING DESIGN OFFICE:(954)771-8149 ! FAX;(954)771-8169 o THRESHOLD INSPECTIONS POOL STRUCTURE DESIGN (Barry Chemical storage bldg..) Entire Unit Masonry System Varies(February 11-2013,March 28-2013 Building Official Miami Shores Village Building and Zoning Department Miami Shores,Florida Re:Barry Chemical Bldg Miami Shores,Florida Permit#: CC-5-12-768 Dear Building Official, I hereby Saad EI-Hage visually inspected and attest that to the best of my knowledge,belief,and professional judgments that the Entire Unit masonry system including but not limited to reinforcing bars,mortar,columns,beams horizontal joint reinforcing,Etc—have been found to be in compliance with the Florida Building Code and the approved plans and specifications. Should you have any questio or need any additional information,please do not hesitate to contact me. Sinc y, i Saad El- age,P.E.#42550 Special Inspector#0965 k< • Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 inspection Number: INSP-190978 Permit Number: CC-5-12-768 Inspection Date: May 06,2013 Permit Type: Commercial Construction Inspector: Bruhn, Norman Inspection Type: Second Floor Slab Owner: , BARRY UNIVERSITY Work Classification: Addition Job Address:11300 NE 2 Avenue Wiegand&Annex Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360010160-09 Project: BARRY UNIVERSITY Contractor: TURNER CONSTRUCTION COMPANY Phone: (786)621-9000 Building Department Comments ADD NEW CHEMICAL STOCK ROOM Infractio Passed Comments INSPECTOR COMMENTS True Inspector Comments Passed Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. For Inspections please call: (305)762-4949 May 08,2013 Page 1 of 1 S A A D EUA EL-HAGS CONSULTING ENGINEERS,INC. __.. _ .... _ .:.,... a .._.,.. • 5601 NW 9TH AVENUE,SUITE 401 / FORT LAUDERDALE,FL 33309 STRUCTURAL BUILDING DESIGN OFFICE.(954)771-8149 / FAX:(954)771-8169 THRESHOLD INSPECTIONS POOL STRUCTURE DESIGN (Barry Chemical storage bldg..) Hollow core system April 04-2013 Building Official Miami Shores Village Building and Zoning Department Miami Shores,*Florida Re:Barry Chemical Bldg Miami Shores,Florida Permit#: CC-5-12-768 Dear Building Official, I hereby Saad El-Hage visually inspected and attest that to the best of my knowledge,belief,and professional judgments that the Hollow core system and the reinforcing for the hollow core system were observed to have been installed correctly including all penetrations. Should you have any questions or need any additional information,please do not hesitate to contact . me. Sincer s -3 3 Sa d I-Hage,P.E.#42550 Special Inspector#0965 +4 H✓:y< s Y r Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-189470 Permit Number: CC-5-12-768 Scheduled Inspection Date: May 06, 2013 Permit Type: Commercial Construction Inspector: Bruhn, Norman Inspection Type: Slab Owner: , BARRY UNIVERSITY Work Classification: Addition Job Address: 11300 NE 2 Avenue Wiegand &Annex Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360010160-09 Project: BARRY UNIVERSITY Contractor: TURNER CONSTRUCTION COMPANY Phone: (786)621-9000 Building Department Comments ADD NEW CHEMICAL STOCK ROOM Infractio Passed comments INSPECTOR COMMENTS False Inspector Comments Passed F CREATED AS REINSPECTION FOR INSP-172941. Work covered without inspection. Provide termite certifcate. to 4J Provide signed and sealed compaction test. NB Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. May 06,2013 For Inspections please call: (305)762-4949 - Page 27 of 48 ELOA Eta-HAGS CONSULTING ENGINEERS,INC. 5601 NW 9TH AVENUE,SUITE 401 FORT LAUDERDALE,FL 33309 STRUCTURAL BUILDING DESIGN OFFICE:(954)771-8149 / FAX:(954)771-8169 -THRESHOLD INSPECTIONS POOL STRUCTURE DESIGN (Barry Chemical storage bldg..) Ground floor slab March 042013 Building Official Miami Shores Village Building and Zoning Department Miami Shores,Florida Re:Barry Chemical Bldg Miami Shores,Florida Permlo: CC-5-12-768 Dear Building Official, I hereby Saad El-Hage visually inspected and attest that to the best of my knowledge,belief,and professional judgments that the ground floor slab has been inspected and that the entire slab and its components are in compliance with the Florida Building Code and the approved plans and specifications. Should you have any questions or need any additional information,please do not hesitate to contact me. 1-17 z/ 7o-*"P -1 zo Sincerely, -3 3,­13 __1 55, Sincerely,rE-Ha P.E.0 42550 Special Inspector#0965 • 1215 WallAce Drive°• Delray Beach, FL 33444 (561)347-0070 • (561)395-5805 (fax) '�rFRNAT10�Pv IN-PLACE DENSITY AND WATER CONTENT OF SOIL AND SOIL AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH) - ASTM 6938 Project: Barry University-Addition Chemical Stockroom &Anatomy, Miami Project ID: 12-1835.00 Address: 11300 NE 2nd Avenue, Miami Shores, FL Report ID: D-0001 Client: Synalovski Romanik Saye Date: 11/19/2012 Permit No: Field Tech: JC Mendez Test Mode: Direct Transmission Area Tested: Wall footings Soil Description: Greyish Brown Fine Sand with little Limestone Rock Proctor/LBR ID: P-002 Max Density (PCF): 106.7 Opt Moisture(%): 12.6% Test Standard: D 1557 Compaction Required (%): 98.0% Probe Elev Wet Dry Moist. Compaction Location Depth Density Density (%) % Results (in) (PCF) (PCF) 1 Wall footing at NW end of corridor 12 BOF 114.0 106.3 7.2% 99.6% Pass 2 Wall footing at SW end of corridor 12 BOF 113.1 105.1 7.6% 98.5% Pass 3 Wall footing south of storage 12 BOF 113.7 105.3 8.0% 98.7% Pass 4 Wall footing at SW corner of building 12 BOF 114.5 106.7 7.3% 100.0% Pass 5 Wall footing north of ramp 12 BOF 114.4 106.0 7.9% 99.3% Pass 6 Wall footing north of lab director office 12 BOF 113.1 105.7 7.0% 99.1% Pass 7 Wall footing north of anatomy lab 12 BOF 113.4 105.9 7.1% 99.3% Pass 8 9 10 11 12 Testing Gauge Information: Manufacturer: Troxier Model: 3430 S/N: 34908 Density Standard (DS): 2328 Moisture Star cdstd' !•., 277 Remarks: .• ��'''•'� !•�- Legend for Elevation: PR= Proofroll 1, 2, 3= 1st, 2nd, 3rd Lift Ntful ittP, A In e', to SL=Springline FL= Final Lift E c SG= Subgrade BG = Below Grade OF :�� BC = Basecourse BOF = Bottom of Footing �• 812012 TOP=Top of Pipe FG = Finished Grade •�� ga °� 'E�G�.•� ' � ' Pr n # 44653 Test report shall not be reproduced,except in full,without the written approval of GFA International State O{NbOda'�� Environmental•Geotechnical•Construction Materials Testing •Special and Threshold Inspections•Plan Review and Code Compliance Florida's Leading Engineering Source www.teamgfa.com