RF-13-1875 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 inspection Number: INSP-201797 Permit Number: RF-8-13-1875 Inspection Date: October 23,2013 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: HERBERT, CHRISTOPHER&LISA Work Classification: Tile Job Address:465 NE 102 Street Miami Shores, FL 33138-2452 Phone Number Parcel Number 1132060170820 Project: <NONE> Contractor: PAUL KAWALEK ROOFING CO. Phone: (305)754-0191 Building Department Comments TEAR OFF EXISTING TILE ROOF, REPLACE WITH A Infractlo Passed Comments NEW EAGLE CAPISTRANO COLOR THRU ,MULTI INSPECTOR COMMENTS False COLOR TILE ROOF SYSTEM. ROOF TILE COLOR PALM BEACH BLEND Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-197517. Missing renailing affidavit Failed Correction Needed Re-Inspection Fee No Additional Inspections can be scheduled until re-inspection fee is paid. For Inspections please call: (305)762-4949 October 23,2013 Page 1 of 1 Florida International Engineering and Testing Lab LLC FeIeEo 16701 SW 117 Avenue, Miami, FL 33177 FLORIDA INTERNATIONAL ENGINEERING Telephone: (305)378-1991-Fax: (305) 378-1997 &TESTING LAB INSIGHT-INNOVATION-INTEGRATION Miami-Dade Lab Certification#07-0612.11-State of Florida ca#27273 ----------------------------------------------------------------------------------------------------------------- L 4 _S .SPE C RMQjION Z Owner's Name:. Job Address: A e "Z 1�5� Roofing Contractor: L '•p1,If ,.� - '� l Y�[_� „ Permit Number: � �° 3- 5 Type of Tile: t�E— � °°'�b.b./�✓t Approximate Roof Height: 2 feet Slope: •• 17L- Approximate Square Footage: Ct?® ft2 Type of Access to Roof: _ <adder OtherRequired Test[ Forc : 35 lbs. Testing Equipment: F.G . 100x Shim o Instrument Date Installed: 'S Date of Inspection:_ 115: I i TEST RESULTS P=PASS, F=FAIL Test P or F Test P or F Test P or F Test P or F Test P or F Location Location Location Location Location 1 21 &e X 41 61 81 2 22 42 62 82 3 23 43 63 83 4 24 44 64 84 5 25 45 65 85 6 26- 46 66 86 7 27 47 67 87 8 28 48 68 88 9 29 49 69 89 10 30 50 70 90 11 31 51 71 91 12 32 52 72 92 13 33 53 73 93 14 34 54 74 94 15 35 55 75 95 16 36 56 76 96 17 37 57 77 97 18 38 58 1 78 98 19 39 59 79 99 20 40 60 80 100 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106,THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. ADDITIONAL TEST INFORMATION t®e®e1er1aAe Perimeter Width: ft RESPF� LY � ED BY: Area Units orft2 No.of Tests ®�®®��P.'\0 E°NSF (9�,�;®®® Perimeter -4 0— ®��,• No 63107 •�• a Cr Field Corners VOA11 Hips&Ridges V ® fiaP y/O'ly-ff% Stat�iCr <t ° 7 1 ■■■■!■!■t■■# !iiif►ia!! ■l�r�■!�!■�1!#/i■!■■■ ■■■■■■■■�#■■'i�##�S��'i�%���#ii■�■i�=':�:!1/t t■iii■ ■■■■■�fi■■iii 1%ii��i#ii�' 1■#� ��%!�#ri!!■■ ■■■■#■!■r■i`�f tip###�t�f!!#i#�1��',a�#��t■#i■■ ■■r■ ■■■r F.'4, i 2##C?�;i■■0F!-4■rNtlM i 0 0SLlA10■0!#0 OBSESS ■■■!#■#r■#/ #%#r#ii##?3!## f•! [ '!#!r!■ir■ ■M■■■/tlV■r■t1r'`s'.1f`..'` f -,�77#lr V 2■#■lr�=-?,d&iii 0■0 0■0 0 ■#■■■l! i■###HNU■##!##ii#t snip, #;inmfl�- ■■!!■■ ■#iiii#i■#tom f f##;#��!##�i��f#�!l�i��ri■#!!!! ■!m■■■■■■ i tf1#T !■R !■5 1■■ ■■#■■t■ ■■■■■■■■� #rff## il�i■■■■#i���".i■flit�■■i■■■■ ■■■■■■it L::�i�!1I##�#iii##�#�■!��fii!#■iilii ■■■�■■■■iii/�I���i�ii rii■■■ii#����f#'�.1i�i■■!■! ■■!■!!#■■il��!�►::%#iri#lrii/��l■1i#,'!�����ii■r!!ii ■■■■■■!■■■i��#\iii■i■i■■it�aiiL� r�l�^■■■■■■■■ ■!!■!!/%mWrI VN##1-4lir SEEM if'�f !!r■■■ !■■■i■■mill!■tom i■i■■■## 1"gail"id■i■LI&I i■■■■■ ■■■■!■■■iii■■�#I!#i##!!�!■iii■�i�4#i�!#r!i■ ■■■■■#i■ilk■#■■■ii■■■■!■■#■■!!■i■ii■!■■■■ ■i■■■■■!!■#!#iii■:■iii■■■■i■■■■■■■■�■�■■■ ■■■■ ■■ ■ ■■■■■ t ■#■■ ■■■■■ ■■■■■m■m■!ir r■■■■r■!!■■■■■■!■■##!■■!■■■■#■!■■■!■■■■■ f ' 10050 NE 2nd Ave Miami Shores, FI 33138 Phone 305-7954204; Fax 305.756.8972 www.miamishoresvillage.com RE. Perm it# F--q®13°- I r75 DATE: 10 U3 113 INSPECTION AFFIDAVIT 0" , licensed as a (n) Contractor/ Engineer/Architect, (Print name and circle License Type) FS 468 Building Inspector License#: 010 S D 000 Q On or about 1.00 P M , I did personally inspect the roof deck nailing and/or (Date&time) b ®f� � C 10 a h secondary water barrier work at �" (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this y of .}- Notary Public, Sate of Florida at Large = ` ill Iilli "General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S.to make such an inspection. Include photographs of each plane of the roof with permit#and address#clearly shown Marked on the deck for each inspection Miami Shores Village Building Department =5_1 2013 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795.2204 Fax:(305)756.8972 - - INSPECTION'S PHONE NUMBER:(305)762.4949 BUILDING Permit No.T--I` PERMIT APPLICATION Master Permit No. FBC 20 Permit Type: BUILDING pp �j OWNER:Name(Fee Simple Titleholder): Chris Rer Phone#: s qq®+ + 7 Address: 4-S A45- 112j h d, -'s City: K 1 ( l"S _6 h 11 re6 State: gip; Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: 14b-5 fVE loan d, I City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated:Yes NO Flood Zone: CONTRACTOR:Company Name: flNAW e1K R®Cf I n Cj Phone#: 30E; 'I S4'Of`7 ' Address: JH°,1C �l W, 1 b q City: Ki r N nnax State: Zip: Qualifier Name: aj.A 1 X/°.wck l eh Phone#: r7 State Certification or Registration#: Certificate of Competency#: 6 66 0oy0 `Contact Phone#: Email Address: ` DESIGNER:Architect/Engineer: Phone#: Value of Work for this Permit:$. g®u C9 0 0 Square/Linear Footage of Work: 50 Type of Work DAddress OAlteration ONew 21Repair/Ree ODemolition Description of Work: ti I Ace , A EaAI py9 Coinostrah® c olor�h�-®ua., o I�-l�e� I®�~ --1 le � F . @1loosp a co l® a es 3'7a 5 m I COLOR THROUGHROOF TILE IS REQUIRED acknowledged by: Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Tndning/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection f e will be charged. Signature _ Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this 16 The for in in trument was ac edge be me thi j day of Attbuti37 ,20 !3,by G 0 day of 202),by or who has produced Fi.ol0Oi) w pers nally known to or who has produced 600M 1J CENd lr As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: :►+° `,•-. - NOTARY P BLIC: ALPHONS M.THOMSUN *: MY COMMISSION#EE21g5 Sign: Jelly 18,2D18 I - 4 ) �: Sign: i0S Print: ueJ — Print' Notary Public -State of Florida �f My Commission Expires.�ut,�/ Z$'yp/y My Co �ssion Commission#EE 128810 Bonded Through National Notary Assn. �ak��a�HaIaakBask�aHsHa�ask�asbsk sksk k�s�aR�+sksask� skiksiaIaIaWHaiiae kdaHaHaakHaskdsHask�skskdsak��aIaakskIaaAaRNaakekb��sksk�a�akaesaskdasssak+k+k8asadxasksakk�asksa�s�ASeBaskskxsxa +k APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)(rev6/4/10) Building and Neighborhood Compliance Department 11805 SW 26 Street(Coral Way) MIA .' E Miami,Florida 33175-2474 • 786 315-2100 OwNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-BumT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami-Dade County Building and Neighborhood Compliance Department 11805 S.W. 26h Street(Coral Way) Miami,FL 33175-2474 Re: Owner's Name: aYi6 N'�►�b�1��' Property Address: 45M5, l®®LYE A. Roofing Permit Number: Dear Building Official: I 4ff2L� �/ /�?- ,certify that I am not required to retrofit the roof to wall connections of my building because: LI The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC), or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). Signature of Pr Owner � oP�Y mlt,�5 Print Name iii STATE OF FLORIDA COUNTY OF MIAMI DA DE Sworn to and subscribed before me this 1B M.TWWSUM day of Ay ftPj7 .20 )3 . SSION 0 EEZ16m BY�'N�at YH4YL r+JAUEr AEUWA i S J*18,2018 PerseaaByifaow>f' Produced ID When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC or with the 1994 SFBC, an affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. i i1rQ! . .._; an f E 1 1 � I =i �r�.�� i it =I •• i • ! .� Ca• qtr r; "&:-1--C ph III loveltstslsiss!Mai#lilta flows■/!t!m Lists!/!/!Nadioommant/loll#!M#ii1!!i!!!1•!r I■ltllil#:#■MMMtIVIIEI /mass m:ltmiititmmltliimi!!/!!!lMlmt1111sa■/#"t/omits!!!! 1#velill:li/M lam:■l:omtomtm011l//!/lll11/tltllalmlollt:ill#/!■a!l100l0oalaill■ Ial!lo*Mmmoox !:i■■it Molls#ill■ll Mi/tltMi#tottltMillol/!///tltMl//aMa■/toot* 1!t■oMMI■:al:t#lslll!!tl■oMlatm*Il":too i�ltilMlim"#■al"MOlanamponommllMtMlal IO:llmOtlllo■a:Ml/Ml:l:::::M:/mmmwwl woi:ltit0veot//vemoll:mMa■sm/ttoto0:a11at Is/:■/M:t:li�t!■MMiit//film:a/io!!lolrl0lMa:l#/!/lllsMtlO:*l:/:allve011aa:MiOl 1#/#/ /MMM■#■M:t■tit/:lMmll'll Lott/tf#t#/tt#it#///ititt/Mt#/#/#it#titttt/Doll■ IOvetve MM#M#■aMve■/MIiM/M�dilMMve■MMtl lift/1111■toiMO/tivei11tttl■lll11veltttvetve#M11ot- Rl::a"0llaM:l own:alas:llGCMlO/:taMm/toil#moisawaoft/tvef ago Nola■#//MlMi:l/otMtr /Mai//s#MaMlMI/vet!/i i r�kt rat ikitt/tali/i/t///it#t!#t*fits##/!/ltilott/t/!lift Il ommoMa/■l!l/MOtM/KA■I�;�'tlia/liitittottlM/!#ot vets#//slit/ t/!/ti#ttsllll I11:olliM/t/110#son es 11L io l_rsklwarotlaMlm##MltliOta:i!lliltall11lt11l/:ve!/!MO#vemltalr I aMMMve/l:0limi11at001 ��i:rrE■/f7lilmmmmtmmolt1mosalvetslis/mms/loft##mativestMl f t■■tveMveve:M:iiilveloimll\l■#/IC!sTrltilltaotM11■11 l#oveasall ■vet!/ltM11mtii/■Mammas Ittsooii/:tttMtve/MtoMll11"Km1 LuMM!"'1�MMattvemti/it/attMMS�/sIveMSSit UH11S01111 rmo:l0lll0:lsMMlve:Moll!::NallAmasl:Gtvei■tll slat(iatl:mlll00lve01M11l:M:to1110:M 4011 tMlltMit::Ml/:MOMml 01111!111■la�rrr•rr�r�eCYl11lPt�lllm/titlmttMlma/:Rlllll0lMUNN* Ilamomum m/vel:llmllMttiltlrw/amlm:oslsrlr lloRllKlto!!!/a0lltlliMl11l:lllliotoa/Ma i/veil/!slat!/MMa11a#fMllllr�t..t'_1:11/vesRal� -r--4111111111 Ml■/t11iveaailtml///Ma!■ rt:MMMtiive00M#oMO■#oM1IM0t: l\N1ioNt/wr#w%#\.tvetiiw 4a:Il!/st0i/tlmiive1111M■lo#velitM* IliM■011:M11ta#illaltl1111:rr'.�r1\ ■*'IO:mli, r,4lslMMsltmmovearlmltimaltiveaama■ 100Mummavel■t#i!Mo!t_rillt�;%mIM�IIi/i1►Lmtiti■ tiormlmuu l:::amllmawasiloilalar rlamummumiml Swoons a. ,1ItY![�tilmlMtalt■i�liMONN NY:AlllwguxoilmllltitmiiiaMMaMiasr 1st/OMOSMason oave11■■owllrl:1it011olalt::ve::moa:►`a1Yr0*�i�lilal:!falls::lllOM##molimr IliwoM at vemllM/samMO iolI0:l11im�o0sa■fiolOMaa!"Y;7rM/t111JUMmt/M/altltmvemmMat/!alto■ ros11vela/IMMaMamoM"!loll:llll00 mlllG YiIMIMI"►�E■1'MM11llllll11llmaMml:lMMliMl110 Knox w w� 1 �rrf�r�- IltMli:imtMM/:tM:iMatlltlllll#�._ rMtl/i#MeMtam#t/aaa#mam!#Mtl/r!/#tor llasoo1r11/ml:l0m11M#/lMt 10lMif!/raiasaliir■oriIlanIi/a■ o■siflslimm7amtamll+Eliot/ iasslm11ao ■/mlmllltaolOtilMOSii/ts0velr r"llolmll:Moll:l■llmall a>!■lioolllllllM!#oMssvem■ rtlM11lloolunmalloltllllltl'ilveLi7`+7M0Mi##U 1MIC�:�:���■ltlMlllta/MtMMMvelolt■Romano IMMM# llrm0ooit/otMatillaver►�trt!1}I1■loMl:llF_=_ rll:amo:aMMo/Ml11MltMmonsoons "moll: ltitMamt1011it/Ill/1M17/!1111#sMial/toMt/"�fi"Iii#Mmtasimott/MOSit/ittMMtta/* 1!111011 011a11ticivet/ttMiGl:�o�MilA�i:#//atM:/tioio•.hove!/Mali:tiitoMO:latveMto/!olio rimM/illNoa Now s#!11110 `-=■.+:alt#!!i!#!s/veMlaMm/mMtoiloiMtalave/t##tttta:samM* IIoo#ve:t m/m:sttM i!s/mM M#1 aM:tlaitm tltsMit t s■MaMoMJmIr.lMI/:oM tiaomioes ve:veo■lM11l11l11o011il:Ma "tveMt tmialmttMaveiM#t lt:a0Mit 111iioMve#velsvel:lit .' : itaaiovestst tlMrlfoveuiatols nMa:i#lnl0 il"ve olMiM�l#Mla#ttlslMtfIMtmmt#/ soM:veotMoM/#wstii#oa■sasiis :: / In OEM t0iMlllt11lott mllMttlltolMairMtmti11m0*f f■t M rr1/M:11Im11tlO�i 0#o�imsi:IM*iaAMtiveMra■itittio lts*i�st�/IM1tMvewve�ralsrIltaiiMttM#MII#"arMwt 11ll IM1a iii#rt#�imti ItMI�i M/{ oo or/l srlNl�ormMM%llOM !1 lrIrnIrIMriRil �is�s to Mona - r t w! ill:ii woimMrl s:mM IM ml:lasmmomoxM in a sl:#Maa■a:llli won ttmlM MWIi IOOi#tiIl�MttvNi s mNiiRiMiM Kiiliioil iMM :anweel Nola mMU MiwveM lu ill Nll/MM■%# 1 M l * "K a, /atM:M11MMm m ltl mIIrr>ixm:!rIst :la# 11Mfioio:l r*i■* i Roddy Building Cade Edition 2007 High Velocity H Mi m Zone Uniform Permit Application Form kc-190 ® tSte2R, AtotAd Roof Svst®m, Roof System Manufacturer:, f Natice.of Acceptance Number. 03 Minimum Design Wind Pressures.it Applicable(From RAS 127 or Calculations): Madmum Design Pressure 3 From the NOA c stem : Msthwl of the attachment: Dy tt 1 :Coo m , e,6 1 Ve. ,ge® $loved Roof System Desci�atNon DeCic : I X 6 'V—To i A] W00 A Undertaymen� Root Slope: nsulation: � :12 �J Flare IV P A Ridge Yenillation? er Type&Spaying: 1 rr i /$ 0 � � —R Ol IV/A dh"I"Type tJ)�SS n rmw's mod, �d Cap Stunt: poly iGK oof Co vexing: i s Oil Moan Roof tlelgl* �c ° Type&Size Drip ala e: a►),La 0tov 123_91-48 121W PAGE 4 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High-Velocity Hunicane Zone Un fwm Pwwdt Applicaftn Form. Section F Co's Calculations) FarldomembasWtilesysmms,chometdwMethod 1 or2.Compatethevaluesforh4whbftvalmkomM4 KtheMfvalaes area tint or equal to the Mr vabw%for each area of the roof,rhea rim rile auschment method is acceptable. p nM] �ond 1QA�Ho> ,ant Based Calcalatioms Far 127" (P,:3gs I x7ls�! L�4i�-MM =mr, Al Mf 39q j (PALXa =.� -Mg: =Ma.11at� Mf�gg��►-- (P I-X --M -Mg I=M3 Xl—% W Aprpa.M mf Method 2-JmpHfied T& Per TableSelow" Mamtent of Resisdamas(Mr)Ftttm Table Below hodact Approval AML uir+ed MMomaM RISWMfIW mean Roof Heigh-► 16' 2e' 2r 30' 4(1' Roof 8 29A 30-4 24.0 712 2" 2LQ 27.1 2fL2 20.0 1 *Must be used in conjwkcdom with a list of moment based We systems endorsed by the Broward Cotrmy Board of Rules and Appeals FarUpllRbssedtgesyst==Medwd3.Com thavahsaaforFwi dkftvaiaasfarlLN*eFvelmweV*owtbmwregtmlretheFrvaWm for am&area of tlas roof.then the rite anchment to t is acoe Wt. Mathod 3"Moaeat Deal Tice CatailsNtms Per RAS 127" (P,: X L = X w:o -W: X cos 8 =Fr, Product Approval F (P2: x L = x w:=_�-W x cos 8 =Fi2 Prodmx Approval F X L X w:= -W: X cos B =F Prodiax F' RodSJow 0 Job Sift Restoring Momma due to M8 Rodeo Approval omvhv Mimumtm P+ ftodm Approval Acuum U Amma We 7M Dhm mdm L=length Prodad Approval a All at FLORIDA BUILDING,CODE r—BUILDING r ' I ®M=WE OWNER'S NOTIFICATION FORM SECTION 1524 HIGH VELOCITY HURRICANE ZONE-REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope.As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.The provisions of Chapter 15 q gP P P p of the Florida Building Code,Building govern the minimum requirements and standards of the industry for roofing system installations.Additionally,the following items should be addressed as part of the agreement between the owner and the contractor.The owner's initials in the designed'space indicates that the item has been explained. e d dri.Aesthetics-workmanship:The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. E6_2. Renailing wood decks:When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). �*3.Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the oqcupants and adjacent units of roofing work to be performed. C04. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance,therefore, roofing nail penetrations of the underside of the decking may not be acceptable.The owner provides the option of maintaining its appearance. [;A,-5. Ponding water:The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Wk.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 15 and 16 herein and the Florida Building Code,Plumbing 7.Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the st uctural assembly(the building itself).The existing amount of attic ventilation shall not be reduced. Exception:Attic spaces, designed by a Florida-licensed engineer or registered architect to eliminate the attic venting, shall not be required. Y-1 Owner's/Agent's Signature: Date: F Contractor's Signature: Permit Number: Property Address: M o1-7e7 12109 t I I MILAAM MAMI--DADS COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street;Room 208 BOARD AND CODE ADMINISTRATION DMSION Miami,Florida 331732474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE(NOM www.miaasidpde.g;�/baildiast Eagle Roofing Products LLC 1575 East C.R.470 Sunmterville,VL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County BNC-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or.material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Capistrano Concrete Tile ,, LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:'Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERKIKATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and foilowed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA#07-1018.09 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tiiggem NOA No.:11-0321.03 t? tY Expiration Date: 10/05/16 Approval Date: 05112/11 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Cafto m Roofing Sub Categary: Roofing Tiles eri Concrete I.SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumtersille,FL.and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2.PRODUCT DESCRIPTION: Man etuMd by Test Product Applicgnt Dlmensians S__pneeations Deascrit�tian Capistrano Concrete L— 17" TAS 112 High profile concrete roof tile. For direct Tile W=12 '/" deck or battened nail-on applications. Thickness=W Trim Pieces 1=varies TAS 112 Accessory trim,clay roof pieces for use at w=varies hips,rakes,ridges and valley varying thickness terminations. Manufactured for each tile profile. NOA No.:11-0321.03 Expiration Date:10/05/16 Approval Date: 05/12/11 Page 2 of 7 2.1 EVIDENCE SUBN,IITTED: Test Agency Test Identifier Test NamelRepart Date PRI Asphalt Technologies B"F-001-02-02 TAS-112 Aug.2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102& 102(A) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108(Nail-On) Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108(Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs.smooth shank nails The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering,Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering,Inc. TAS 101 (Mortar Set) The Center for Applied 25-7094-(3,6& 9) Static Uplift Testing Oct. 1994 Engineering,Inc. TAS 102 The Center for Applied 25-7120-(1 &2) Static Uplift Testing Nov. 1994 Engineering,Inc. TAS 102 The Center for Applied 25-7183-(3&4) Static Uplift Testing Feb. 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7214{3,4,&7) Static Uplift Testing March,1995 Engineering,Inc. TAS 102 The Center for Applied 25-78044 Static Uplift Testing Sep. 19% Engineering,Inc. TAS 102 Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services TAS 101 Celotex Corporation 520191-2-1 Static Uplift Testing March 1999 Testing Services TAS 101 Walker Engineering,Inc. Calculations Aerodynamic Multiplier Sep.2006 NOA No.:11-4321.43 Expiration Date.10/t1S/16 Approval Date. 05/12111 Page 3 of 7 S ' 3. LnuTATms: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set file applications,a static field uplift test in accordance with TAS 106 may required,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 1.12,appendix'A'.Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30190 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicablb building cod6. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight and Dimensions I x w Tile Profile Welght W(Ibf) Length-1(ft) Width-w(ft) Capistrano Concrete Tile 10 1.417 1.04 Table 2: Aerodynamic Multipliers-A ft Tile A(ft A(ft Profile Batten Application Dirac Deck Appil ation Capistrano Concrete Tile 0.300 0.277 Table 3: Restoring Moments due to Gran -M ft4 Tile 3":12" 4":1Z" 5":12" 6":12" Greater than Profile T'•12" Capistrano Battens Direct Battens Direct Battens Direr Battens Direct Battens Direct Concrete Tile Deck Deck Deck Deck Deck 6.68 1 6.99 1 6.57 6.88 6.44 6.73 6.28 6.56 6.10 6.38 NOA Ne.:11-0321.03 n Expiration Date: 10/05116 • Approval Date: 05!12/11 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment-Mf(ft4bf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132"plywood) (min.19132"plywood) Capistrano 2-10d Ring Shank Nails 28.6 41.2 19.4 Concrete 1-10d Smooth or Screw 5.1 6.8 2.8 Tile Shank Nail 2-10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1#8 Screw 20.7 20.7 18.1 2#8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1-10d Smooth or Screw 29.3 29.3 24.0 Shank Nail F..ave Clip) 2-10d Smooth or Screw 27.6 27.6 38.6 Shank Nails Field Clip) 2-10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) 2-10d Ring Shank Nails 33.1 48.1 46.2 1. Installation with a 4"file headiap and fastemers are located a min.of 2W from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Capistrano Concrete Tile Adhesive 29.3 1 See manufactures component approval for Installation gggirements. 2 Flexible Products Company TIIeBond Average weight per patty 10.7 grams. PolyfOrn Product Inc.Average we ht per patty 8 grarns. Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Single Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Capistrano Concrete Tile Po~Po Prole 66.5 PoWmm Pol ProTm 38. 3 Larne paddy placement of 63grams of PoWroTU. 4 Medium paddy placement of 24 rams of Pol Pro*". Table T:Attachment Resistance Expressed as a Moment-Mf(ft Ibf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Capistrano Concrete Tile Mortar Set 24.5 ti Tile-Tite Roof Tile Mortar. NOA Noal14W1.03 MRAM a1r Cou r Expiration Date: 10AW16 Approval Date: 05112111 Page 5 Of 7 5. LABELING: All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo(See Detail Below),or following statement: "Miami-Dade County Product Control Approved". LORIDA CAMMUNO CONCRETE ROOF TILE LABEL,SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following. 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building coda in order to properly evaluate the installation of this system. I �I NOA No.:11-0321.03 c Tr Expiration Date:1OMS116 Approval Date: 05112!11 Page 6 of 7 1 . 1 PROFILE DRAWING 1 CAPISTRANO CONCRETE ROOF T LE END OF THIS ACCEPTANCE NOA No.:114321.03 Expiration Date:10ION16 Approval Date: 03112/11 Page 7 of 7 r � a MIAMI FOQE=E: MrAW-WADE COUNTY i PRODUCT CONTROL SECTION DEPARTMENT OF PERNUTfING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Shvd,Room 208 BOARD AND CODE ADMINLSTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.nflamidade.eovbera 3M Company 3M Center Building 0220-05-E-06 St.Paul,MN.55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. N this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material falls to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:3M'm 2-Component Foam Roof Tile Adhesive AH 160 LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein, RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.:12-0228.18 h0Ahl4 DAnE COUM7 Y Expiration Date:05/10/17 Approval Date:05/10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3WT4 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance.For the batons where the design pressure requirements,as determined by applicable building code,does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127,for use with approved flat,low,and high profile roof tiles system using 2-Component Foam Roof Tile Adhesive AH-160.Where the attachment calculations are done as a moment based system for single patty placement,and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensoons Test Product Description Specifications 3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF1000 N/A Dispensing Equipment ProPack8 30& 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted.Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbsJft 3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 LbsJFiz Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.070/.Volume Change @-40°F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% NOA No.:12-0228.18 Expiration Date:05/10/17 haa�Nn�ecou�rrY Approval Date:05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agencv Test Identifier Test Name/Report D,ate Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02195 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 O1-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex.Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof file adhesive with their the assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F ,W, 2 F`= MS NOA No.:124228.18 r auaoE Expiration Date:OWO/17 ... , Approval Date. Page 3 of 7 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160. 2. 3Mrm 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance,expressed as an uplift based system,to meet or exceed the uplift resistance determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A"component and the"B"component shall be maintained between 1.0-1.15(A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or ProPackV 30& 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 2 to 3 minutes after 3MT9 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details'herein. Each generic file profile requires the specific placement noted herein. Table 1:Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per Min.(grams) paddy Min.(grams) Flat,Low Ifigh Profiles #1 35 NIA Mgh Profile 2 Piece Barrel #1 17/side on cap and 34/ N/A Flat,Low High Profiles #2 24 1 N/A Flat,Low,High Profiles #3 8 NOA No.:12-0228.18 MIAMFDADE COUNTY Expiration Date:05/10/17 M Approval Date:05/10/12 Page 4 of 7 LABELING: All 3MTM 2-Component Foam Roof Tile Adhesive AH 160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY w"n*0w c w" Nd♦fhrM000ft lte 1 un&*Pw ° = wdwkyP=wnt 101n 10 EMCM MS E FOS* Fash CNMO* EM Eamdan EareMM 1)PlaIDemogg6adroUosddsm17b23 Pfth WOP _ 4T=cwm dow I:=1WhWw 12 TO,I L Ftan adddee Of amtUL Um61tE80tl19ft 0 nr 101n I o 0 Encom EswWNW -- EMCMMO r: 11oopp = Keep Fssdo dd� AbrioondSA powwowsSae d Pdot�NWtsr tAdemon m edgesa(dM Esmdoman WenWoub Feede NOA No.:12-0228.18 Expiration Date:05/10/17 haahll o�►°���� Approval Date:05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY tl�roughp moment "M M01%) "h pmft amt ( ►'k) 7�n 7h Fes* FOS* rarecowae °� ° ° Em aoeae D*WP wo* "t la ) EMCWSM rmcou NOA No.:12-0228.18 tte Lout Expiration Date:05/10/17 .. Approval Date:05/10/12 Page 6 of 7 n . o ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY 1114 ft o*pMft mmd Ilan t"No pig cement single paddy undertie undmbymw'\ (batvw�n tae) W419 paddy betwaen tfle ° �) 2 in.x 7 b4 glum ° (under ° course dyem+e in. underlie box 3 in. Tx 3 in. _===_ 41n. . Z 1M paddy on 21n 41n. pe� ° paddy �m undue Fesda ° � layment -_ on top of We 0=NO paddy XT bL med m EM Em domne ntop�ofmq dw paddy eave % calm ftedp Fastda ccumady through p cement ndertHe Single ley between tae Jt�In.x3bL 4 sh"paddy ° 2 n. Emcmm on top of tits Z ln.xT di.mad m EmCcm F END OF THIS ACCEPTANCE NOA No.:12-0228.18 Expiration Date:05/10/17 rw►Mt nape courmr Ezpir Approval Date:05/10/12 Page 7 of 7 MIAMt•DADE, }„ MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamfdade.a Polyglass USA Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.U this product.or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by MiamiDade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:Polyglass Polystick Underlayments LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA-Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0713.02 rnaMFnwoE cotnlrr Expiration Date: 09/13/16 Approval Date: 02114/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Cater-o Roofing Sub-CatWM Underlayment Material: SBS,APP Self-Adhering Modified Bitumen PRODUCTS DESCRDPTIUN: Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous,rubberized asphalt underlayment 6528"x 3'3-3/8" waterproofing membrane,glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Polystick IR Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering, underlayment 65'x 31-3/g" ASTM D 1970 APP polymer modified,fiberglass reinforced, Manufacturing Location Or 65'x 3' bituminous sheet material for use as an #1&#2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice&rain shield and as a flat roof tile underlayment.. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP underlayment 32'10"x 33-;/s" ASTM D 1970 polymer modified,fiberglass or polyester Manufacturing Location 100 mils thick reinforced,bituminous sheet material for use as #1&#2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering,glass- underlayment 65'x 3'V/8" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane.Designed as a metal roofing and roof Manufacturing Location file underlayment. #1&#2 Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10"x 3'3j/g- ASTM D 1970 glass-fiber/polyester reinforced,with a granular Manufacturing Location 130 mils thick surface designed for use as a the roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and . A rubberized asphalt self-adhering,glass- Manufacturing Location 61'x 3'3 3/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane.Designed as a metal roofing and roof file underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass- Manufacturing Location 61'x 3'3 3/$" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 ra�►M we ED I rr Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self-adhering,polyester Manufacturing Location 65'8"x 3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed #2 60 mils thick as a a roof tile underlayment. MANUFACTURING PLANTS: 1.Hazelton,PA 2.Winter Haven,FL EVIDENCE SU1aMTrrm Test Agency Test Identifier Test Name/Rego PH" Exterior Research&Design,LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11 P40390.08.12-1 TAS 103&TAS 110 08/06/12 P40390.08.12-2 ASTM D 1623 08/07/12 P40390.10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PR101111 ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09 Momentum Technologies,Inc. JX20117A TAS 103/ASTM D4798&G155 04/01/08 RX14E8A TAS 103/ASTM D4798&G155 11/09/09 DX23D8B TAS 103/ASTM D4798&G155 02/18/10 DX23D8A TAS 103/ASTM D4798&G155 02/18110 Mu►r�ie counirtr NOA No.: 12-0713.02 � Expiration Date: 09/13116 Approval Date: 02/14/13 o f8 Pace 3 INSTALLATION PROCEDURES: Deck Type 1: Wood,non-insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6"o.c.at a minimum 4"head lap.(for base sheet only) Membrane: Polystick membranes self-adhered Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the cave,rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 32"and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 5. For ridge applications,center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 12-0713.02 haar��•ae►oe co�I Expiration Date: 01/13/16 Approval Date: 02/14/13 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS,TU Plus,Tile Pro and Dual Pro may be used in asphaltic shingles,wood shakes and shingles, non-structural metal roofing,roof tile systems and quarry slate roof assemblies.Polystick IR Xe,TU,and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth,clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times;not to exceed the preceeding maximum time limitations. sure Limitations da MTS Ht Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven,FL. 180 180 180 180 180 180 180 90 Hazelto PA. N/A 30 30 180 N/A NIA N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. S. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance.Polystick TU,TU Plus,Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications.Polystick IR Xe,and Dual Pro are limited to mechanically fastened roof tile applications.Polystick MTS is limited to mechanically fastened with battens roof tile applications.Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof file underlayment for(direct-to-deck)tile assemblies shall be as follows:(See Table Below) Tile Proille Polystick MTS Polystick IR Xe Polystick TU,TU Polystick TU Plus,TU P,Tile Max Pro Flat Tile Prohibited without 5:12 No limitation No limitation battens Profiled Tile Prohibited without Prohibited No limitation No limitation battens The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. roa�aaAUe cauNnr NOA No.: 12-0713.02 .. , Expiration Date: 09/13/16 Approval Date: 02/14/13 a _ Paee 5 of 8 GENERAL LIMITATIONS:(CONTINUED) 10. Care should betaken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment.Refer to Polyglass'Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. I Rooting Tiles ,6 Max Per Stack) I I � i - -. 12 o �— g CL N Dmuea pmparea vwm IOLWnCKTU Plus 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products.Polystick MTS,IR Xe,TU,TU Plus,TU P,TU Max,Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR Xe, TU,TU Plus,TU P,TU Max,Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS,IR Xe,TU,TU Plus,TU P,TU Max,Dual Pro and Tile Pro is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control III Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. I LABELING: 1. All membranes or ac shall bear the . t or identifiable marking of the manufacturer's name or logo, packaging �Prin g city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. MOAhU•DADE COUNTY •• BUILDING PERMIT REQUIREM>;rl m: Application for building permit shall be accompanied by copies of the following: 1.This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 12-0713.02 NnnuE Expiration Date: 09/13/16 Approval Date: 02114/13 Paut 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1"metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of 12"o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area pars clavar"on the face of membrane,with the above stated nails and/or disks.The head lap membrane is to cover the area being back-nailed.(Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric;and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement,applied in between the application of the lap.The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading the on the underlayments.Refer to the Polyglass Tile Loading Guidelines.See General Limitations#9 and#10. 6. Battens and/or Counter battens,as required by the tile manufacturers NOA's,must be used on all projects for pitch/slopes of 7"/12"or greater. It is suggested that on pitch/slopes in excess of 61/4"/12",precautions should be taken,such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. & Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair,followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 401bs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request.It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 12-0713.02 Expiration Date: 09/13116 Approval Date: 02/14/13 Page 7 of 8 r e e 13. Questions in regards to the application of Polyglass products should he directed to our Technical Services Department at 1 (800)894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association(NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIT IITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 124713.02 M�aM40AD8 cD 1 Expiration Date: 09113/16 Approval Date: 02/14/13 Page 8 Of 8