Loading...
RF-13-1821 i Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-197052 Permit Number: RF-8-13-1821 Scheduled Inspection Date: September 11,2013 Permit Type: Roof Inspector: Naranjo, Ismael Inspection Type: Final Roof Owner: EAST CONDOMINIUM INC,SHORES Work Classification: Repair Roof 01 A7 A Job Address:717 E 91 Street BLDG B Miami Shores, FL 33138-0000 Phone Number Parcel Number 113206044001 Project: <NONE> Contractor: ALL CONSTRUCTION &DEVELOPERS INC Phone: (786)7684330 Building Department Comments TILE REPAIR Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Ea c., Al 's Failed 66 Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. September 10,2013 For Inspections please call: (305)762-4949 Page 11 of 28 i I L R e eh��E Esgginn�e�ring Carp. s 2370 S.W.123 Avenue Miami,Florida 33175-1174 Tel:305-823-8008/305-397-6414 EER Fay 305-823-3300/305-884-8834 Website:www reilehengineering.com September 9, 2013 All Construction and Developers 1000 - 5 Street Suite 200 Miami Beach, Florida 33139 Project: ROOF TILE UPLIFT TEST REPORT Existing Building 717 Northeast 91 Street Miami Shores, Florida Information provided by client: Permit Number: Not Provided Date Completion: September 5, 2013 Roofing Contractor: All Construction and Developers Project Number: 13-0677 (Testing Laboratory Certificate #11-0715.04) Dear Sirs; In accordance with your request and authorization,a representative of Reileh Engineering("orporation completed the Roof Tile Uplift Test for the repaired area at the above referenced project. This testing%A as performed in general accordance with Roofing Application Standard TAS No.106--Standard procedure for field verification of the bonding of mortar oradhesive set tile system and mechanically attaQne-d,rigid, discontinuous roof systems. The total of the tested roof surface area was less than 1000 square feet,and the mean height of the roo f is less than 40 feet above ground surface. The type of tile used for this project was reported-*o be concrete/clay Roof Tile. This tile was reported to have been foamed in place. At the time of our inspection,the entire area of the roof was examined for loose til es. Not less than one (1)tile in ten(10)of all components in the field area and one(1)tile in five(5)of all tiles in the perimeter and comer areas were physically examined. A minimum of one(1)test per every two(2)sgpares in the field,one(1)test per square in the perimeter area,ridge caps and(1)in the comer areas were conducted. Based on our test results,we conclude that the installation of the roof the at the above referenced protect meets the test requirement outlined in the above-mentioned protocol. Attached please find a copy of o?�r test report for your review. Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. lfyou have aRy questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation f r ' arnad Sonny Salleh, P.E.49014 Project Manager TILE UPLIF F TEST Existing Building 717 Northeast 41 Street Miami Shores,Florida Reileh Engineering Corporation--Project Number- 13-0677—Page 2 of 3 Report of TILE UPLIFT TEST for v Existing Building 717 Northeast 91 Street Miami Shores, Florida Project Number: 13-0677 Test Number Test Load (lbf) Test Status 1 35 Pass I, 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass Test 1-3 Perimeter, 4-8 Field Reileh Engineering Corporation--Project Number- 13-0677—Page 3 of 3 NOf:1"N is 2 3 8' 6 S 4 7 B N01 11 CI.LM19 151"SE 30 5F O f;It7G�CAP 151 I OCA110N FEW COC;NR 0 5� rMMM � COMM - 0 f'L�IWtV n15MNC�,a - 3' L 19 NOT�5 005 VIP6E CAP - 0 COPNM MM- 3'X 3' APPPDX,V00F t5T LOCATION5 ANn 121WN51ON5 Miami Shores Village AO Building Department J � 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 S ' Tel: (305)795.2204 Fax: (305)756.8972 INSPECTION'S PHONE NUMBER: (305)762.4949 FBC 20 l c� BUILDING Permit No. PERMIT APPLICATION Master Permit No. `— 8 0 rDl Permit Type: BUILDING ROOFING JOB ADDRESS: 117 0j I T fop..+ ck. T 5 City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple TitleholdArl'-°' OCG6?1 fig, EA5 Civj Phone#-PD I-15 a O Address: �1 I sE 011 ctmre� 4 �a-9-Z 3(4-C'gO City: �* A 1AivV1 t®I�GS l State: �° Zip: Ob Tenant/Lessee Name: Phone#: Email: 4056 m s e, A-ff 1A51— CONTRACTOR: Company Name: Phone#: 3 Q r- 444 3 Addres : City: State: Zip: IS a I Qualifi r Name: 0 R Phone#: State Certification r Registration#: d5� Certificate of Competency#: Contact Phone#: 4' ') � Email Address: DESIGNER:Architect/Engineer: Phone#: _ � PP) Value of Work for this Permit:$ Square/Linear Footage of Work Sr Type of Work: ❑Addition ❑Alteration ONew epair/Replace LIDeniolition Description of Work: 2 (10011 Color thru tile: Submittal Fee$ D °t� Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ _ TOTAL FEE NOW DUE$ ' f I Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip I Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR . ' IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." .Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature weer or Agent V&Ahtractor Lh regoing ins ent was acknowledged before me this��t-The fore oing ' ment was acknowledged before me this ,ZO 13 ,by tr.Q&9T 6 vmm l e—e day o 4 Y�." persona known to me�br who has produced who ersonally kno o me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOT P Sign:— ... Sign: Print: �$�� A . R 2 Print: My Conunission Expires. �..&V wry pubfic Std d FWrft My commission Expires: .atr",rN WAYS Labmda . Oaoar M Zaragoza COIiMrAWN#11/21200 C DES tszo8 '., �•pgRE& MAY 23.2017 � W; 1V W' K0W." APPROVED BY g l �J Plans Examiner Zoning Structural Review Clerk (Revised 5/2/2012)(Revised 3/12/2012))(Revised 06/10/2009)(Revised 3/15/09)(Revised 7/10/2007) ! J .1 AM Shares Plaza East Condominium.AssodA2Hon,Inc. 746 North East 9144 street Miami Shores,FL 33138 305-759-9069/FAX 305-759-2101 E-MAIL spe123 @att.net August 1, 2013 Miami Shores Village Building Dept. 10050 NE 2nd Avenue Miami Shores, FL 33138 Dear Sir/Madam: This letter will serve as your confirmation that"All Construction& Developers, Inc." has been contracted and is authorized by the Board of Directors of the Shores Plaza East Condominium Association to perform roof repairs at building 717 NE 91 Street, Miami. Shores, Fla. Should you have any questions regarding the enclosed, please feel free to contact the condominium office. Sincerely yours, Robert Gonzalez President cc: file p,pauiara.rJr 6 Yea .� 4p a Tjl � 9eq.ee £ n g {6 r t JEFF ATWATER •a� . CHIEF FINANCIAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS'KERS COMPENSATION * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS C ** OMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers'Compensation law. EFFECTIVE DATE: 8/22/2013 EXPIRATION DATE: 8/22/2015 PERSON: CORREDOR MAURICIO FEIN: 208363228 BUSINESS NAME AND ADDRESS: ALL CONSTRUCTION& DEVELOPERS INC 1000 5 STREET MIAMI BEACH FL 33139 SCOPES OF BUSINESS OR TRADE: LICENSED GENERAL ROOFING-ALL KINDS CONTRACTOR AND DRIVER Pursuant to Chapter 440.05(14),F.S.,an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter.Pursuant to Chapter 440.05(12),F.S.,Certificates of election to be exempt...apply only within the scope of the business or trade listed on the notice of election to be exempt Pursuant to Chapter 440.05(13),F.S.,Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if,at any time after the filing of the notice or the Issuance of the certificate,the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate.The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 07-12 QUESTIONS?(850)413-11309 13 Miami Shores Village APPROVED BY DA LOCITY yURRICANE ZONES ZONING DEPT // BLDG DEPT 8'`I v � 4' E SUBJECT o OCNIPI MICE Wl rH ALL FEUER L zY Florida ifdlt tg H h Vei Hurrit�ne Zone Uniform Parmit A cation Form. ■ Section A (General Information) Master Permit No. fProcess No. I Contractor's Name—/// ��✓�5�r''(�t�/i �,✓t� a,Lk Le!E&,; _ l C Job Address ROOF CATEGORY ■ ❑ Sir Low Slope ❑ Mechanically Fastened Tile Mortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Woad Shingles/Shakes Shingles C ❑ Prescriptive SUR-RAS ISO ROOF TYPE ■ �J New Roof ❑ Reroofing ❑ Recovering iJ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Law Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF) : Section B (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. • ■ • .� .1 .. 14t ■ ... /rya ■ ■ r ■ ■ nn4n of nntnA no ttt Mkl^wwn� s•�w.w....w.. HIGH-VELOCITY HURRICANE ZONES i Florida Building Code Edition 2010 High Velocky Hurricane Zone Uniform Permit Applicadon Form, Section D (Steep Sloped Roof System) r Roof System Manufacturer.-Y&V117 Product Approval Number: 1-2°- ozo( 0` , Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): PI: P2' P3: Maximum Design Pressure Product Approval Specific System: -7 s Method of the attachment: Steep Sloped Roof System Description Deck Type: ype Underiayment: Roof Slope: insulation: : 12 : Fire Barrie Ridge Ventilation? Fastener T pe&Spacing: l� �- X01) j , ;,� � �t5� A; w dhesive Type: PCa� � � r ype Cap She • 1 ��,5"j ' l'�u oof Covering: Mean Roof Height: CQ,,,,,� Type &Size Drip dge: I Min FLORIDA RUILnINCC nnnP_QRCInimmAa Inc- 745 North East 91"Street Mlwnj Shores,FL 33138 305-759-9085—bok*/Fax TheSPIECA1 xMMMIRLmd—E-Mail Property Layout w S N t (USO iY �:n• t 4� B, $R i; L o It It �° r rT I�• ,: 713 �''...... ' A 717 e e :3 ,4�d "gd,w 725 37 9 b. U sa s u s 716 y 723 so M C 735 W.vari4m N. �`- S.L v.irwnV L 1 I 1 "14 Isis r T 725 L .- r A-Cvndu a vullte gRitww '•°- 0-Slvrnue C•wundry .1.L _- warWnu L F 736 1 9140 S H s1 t 9120 /� 9160 M t : 7 G ! 4la r.�. e t t N.B.8th Avemm A 1 SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system Installations. Additionally,the following Items should be addressed as part of the agreement between the o ' r the contractor.The owner's initial in the adjacent box indicates that the item has been explained. .Aesthetics-Workmanship:The workmanship provisions of Chapter 15(High Velocity Hurricane Zone) a or the purpose of providing that the roofing system meets the wind resistance and water Intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship t' ' esthetic issues such as color or architectural appearance,that are not part of a zoning code,should as part of the agreement between the owner and the contractor. nalling Woad Decks:When replacing roofing,the existing wood roof deck may have to be renailed with the current provisions of Chapter 16 (High Verity Hurricane Zones) of the Florida Building of deck is usually concealed prior to removing the existing roof system). ommon Roofs: Common roofs are those which have no visible delineation between neighboring nhouses,condominiums, etc.). In buildings with common roofs,the roofing contractor and/or owner s notify the ocxupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed,open beam ceilings are where the underside of the roof decking can be A from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail etrations of the underside of the decking may not be acceptable. The Florida Building Code provides the f maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may ca water to pond (accumulate) In low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the fife e cy and performance of the new roofing system. Ponding conditions may not be evident until the original system is removed.Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not ov ded from a build up of water. Perimeter/edge walls or other roof extensions may black this discharge If 0 ow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accordance Florida Building Cade, Plumbing. 7.Ventilation:Most roof structures should have some ability to vent natural airflow through the interior of the aural assembly(the building itself).The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. 3wnee ent' 'gnature Date Coptractor's Signature �— � a property Address Permit Number Rew1/20/200aComputer Servjws,Building Departm.ent x t ' m MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) a-ww.miamidade eov/Dera Lamoti Roof Tile,Inc. 1390 NW 29 Street Miami,FL.33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barrel High Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, and tollcw�d b the tY� � Y expiration date may be displayed xp y m advertising literature. If any portion of the NOA is distila�ved,then it shall be dine in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer rr ks distriliatvrs and shall be available for inspection at the job site at the request of the Building Official. This renews NOA#06-1214.07 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. a Ia1aI��uAcctul+frr NOA No.: 12-0207.02 • Expiration Date:03/14/17 Approval Date:05/31/12 Page 1 of 5 e C C ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: High Profile Roofing Tiles Material: Concrete 1. SCOPE This renews a roofing system using Lamoti Barrel High Profile Concrete Tile, as manufactured by Lamoti Roof Tile, described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code. For the locations where the pressure requirements, as determined by applicable building code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein.The attachement calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barrel Concrete Tile Length : 18" TAS 112 High profile,two piece,concrete roof tile. For Width : 8 3/4" direct deck,adhesive set applications only. Thickness : %s" Trim Pieces I=varies TAS 112 Accessory trim,concrete roof pieces for use at hips, w=varies rakes,ridges and valley terminations. varying thickness Manufactured for each tile profile. 2. 1 PRODUCT DESCRIPTION 1. Miami,FL. 2.2 SUBMITTED EVIDENCE: Test Azency Test Identifier Test Name/Report Date IBA Consultants, Inc. 2358-54 TAS-101 05/08/07 American Test Labs of South RT0511.02-12 TAS-112 05/16/12 Florida NOA No.: 12-0207.02 Expiration Date:03/14/17 Approval Date:05/31/12 Page 2 of 5 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix W. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 2":12"to 7":12" 4. INSTALLATION 4.1 Lamoti `Barrel high Profile Concrete Tile' and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W)and Dimensions(I x w) Tile Profile I Weight-W(lbf) Length-1 (ft) Width-w(ft) Barrel High Profile Concrete Tile 1 8.1 1.50 0.73 Table 2: Aerodynamic Multipliers -I(fe) Tile x(ft ) x(ft) Profile Batten Application Direct Deck Application Barrel High Profile Concrete Tile WA 0.23 Table 3: Restoring Moments due to Gravity-Mg (ft4bf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" Greater than Profile 7":12" Barrel High Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck �irPGt Deck Profile 5.66 5.56 5.43 5.25 6.01 4J2 i Concrete Tile Table 6: Attachment Resistance Expressed as a Moment-Mf(ft4bf) 1 for Single Patty Adhesive Set Systems 1 Tile Tile Application fglirimum Attachment I Profile Resistawioa Barrel High Profile Concrete Tile Polyfoam Polypro AH 160TP° 77.87 1 Paddy placement of 37 grams of PolyproAH 160TM for pan tile, 17.5 grams on each side for ca tiles. cv NOA No.: 12-0207.02 • • Expiration Date:03/14/17 Approval Date:05/31/12 Page 3 of 5 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below),or following statement: "Miami-Dade County Product Control Approved". LRT LAMOTI BARREL CONCRETE TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0207.02 rwaM4nausco Expiration Date:03/14/17 Approval Date:05/31/12 Page 4 of 5 PROFILE DRAWINGS 711 8.7511 2" 2" — I I I � 1 I i I I I 1 I I I I t 1 18" BOA G� 18 LKS t 1 t I t I I I 1 I I I i t 1 3" BONDING LOCKS 2.. 8.75" 8.75" LAMOTI ROOF TILE"BARREL CONCRETE TILE" END OF THIS ACCEPTANCE MAMDA NOA No.: 12-0207.02 MU Expiration Date:03/14/17 Approval Date:05/31/12 Page 5 of 5 C�11�4,iw11 MIAMI-DADE COUNT'S PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street-Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami. Florida 33175-2474 F(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.iiiiamidade.eov/building„/ Polyglass USA Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County BNC-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayaments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#09-0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. w r NOA No.: I1-0601.10 M1IAMFDAI76CCiuIVYY Expiration Date: 09/13/16 s Approval Date: 09/15/11 Page I of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Cateeorv: Underlayment Material: SBS,APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Descrintion Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 65'8"x Y3_'/8" waterproofing membrane,glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing,roof tile, slate tiles and shingle underlayment. Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering, underlayment 65' x 313'/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 80 mils thick underlayment in sloped roof assemblies. Designed as an ice& rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP underlayment 32'10"x 3'3'/$" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 &#2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A non-wicking fabric surfaced,self-adhering, underlayment 65' x 3'3-'/8" ASTM D 1970 APP polymer modified, fiberglass reinforced (Facer of Membrane 80 mils thick with a high strength polyester fabric, bituminous with surface printing) sheet material for use an an underlayment in Manufacturing Location sloped roof assemblies. Designed as a metal #1 &#2 roofing and roof the underlayment. Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10"x 3'3'/8" ASTM D 1970 glass-fiber/polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a the roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass- Manufacturing Location 61' x 3'3'/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11-0601.10 M bDADE C NTY xpiration Date: 09/13/16 •• 4 Expiration Date: 09/15/11 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Sisec Product Dimensions ificatiGn Description Polystick Dual Pro Roll: ASTM D 1970 A rubberized asphalt self-adhering,glass- Manufacturing Location 61' x 3"V/8" fiber/polyester reinforced waterproofing #2 60 mils thick membrane, specific for use as a high temperature underlayment. Designed as a metal roofing. MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Name/Report Date Exterior Research&Design, LLC 11756.04.01-1 TAS 103 04/27/01 11 756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P 10870.09.08-R 1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 &G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 PRI Asphalt Technologies PRI01 I 1 I ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798 &G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 &G155 04/01/08 RX14E8A TAS 103/ASTM D4798&G155 11/09/09 DX23D813 TAS 103/ASTM D4798 & G155 02/18/10 DX23D8A TAS 103/ASTM D4798&G155 02/18/10 NOA No.: 11-0601.10 M tMGt ►DECQUNTY Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 3 of 8 r , INSTALLATION PROCEDURES: Deck Type 1: Wood,non-insulated Base Sheet: One or more plies of ASTM L 226 Type 11 or ASTM L 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding 1 Bads. Re-fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris peior to application. 2. Place the underlayment over metal drip edge in accordance with RAS I 11. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'/z"and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications,center the membrane and rol I from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA loo.: 11-0601.10 MlA 1 Rr4DECOUM'Y Expiration Date: 09/13/16 •• • ► Approval Date: 09/15/11 Page 4 of 8 GENERAL ..IMITATIONS: L Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus,and Tile Pro may be used in asphaltic shingles, wood shakes and shingles,noii- structural metal roofing,roof the systems and quarry slate roof assemblies. IR-Xe, TU,and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof the systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be kdhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the proceeding maximum time limitations. Exposure Limitations(days) MTS II2-Xe TU Tit Plus TU P Tile Pro Dual Pro Winter Haven,FL. I80 180 180 180 180 180 180 Hazelton,PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 913-72 of the Florida Administrative Code. 8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR-Xe, and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications.Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for(direct-to-deck)the assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick III-Xe Polystick TU,TU Plus,TU P,Tile Pro Flat Tile Prohibited without battens 5:l2 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA Igo.: 11-0601.10 Expiration Date: 09/13/16 Approval bate: 09/15/11 Page 5 of 8 r GENERAL LIMITATIONS: (CONTINUED) - 10. Care should be taken during the loading procedure to keep foot traffic to a irtinimuin and to avoid dropping of the directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be load_ed onto battens. Roofing'riles (6 Max Per stack) CL 12 0 6 co . Rpof Deck prepared vdth P01261ICKTU Plus 11. Refer to prepared roofing system Product Control Notice of Acceptance for I fisted approval of this product with specific prepared roofing products. Polystick MTS, IR-Xe,TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR-Xe,TU,TU Plus,TU P,Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR-Xe,TU,TU Plus, TU P,Dual Pro and Tile Pro is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. rJn�coin BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11-0601.10 man Expiration Date: 09/13/16 • • Approval lute: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYS t ICK MEMBRANES: I. Polyglass does accept the direct application of Polystick underlayrnent membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Pius should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, I 1 gauge ring shank type, applied with a minimum I"metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12"o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar"on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric;and granule over granule end laps,shall have a 6"wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule-Hide 241 Premium Modified Flashing Cement, Mule-Hide 251 Premium Wet/Dry Elastomeric Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic,applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading the on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations#9 and#10. 6. Battens and/or Counter-battens,as required by the the manufacturers NOA's, must be used on all projects for pitch/slopes of 7"712"or greater. It is suggested that on pitch/slopes in excess of 6 '/"/12",precautions should be taken,such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation &before loading of roofing tiles is Forty-Eight(48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement,Mule-Hide 241 Premium Modified Flashing Cement. Mule-Hide 251 Premium Wet/Dry Elastomeric Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair,followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Broom ing maybe used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 11-0601.10 >�1 'guAOECOU�t7v Expiration Bate: 09/13/16 Approval Bate:*09/15/11 Page 7 of 8 13. Questions in regards to the application of Polytg lass products should be directed to our Technical Services Department at 1 (800) 894-4563. • 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (N RCA)- PLEASE CHECK WITH LOCAL BUILDING COZIES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS CCEPTANCE NOA No.: 11-0601.10 rKr;4r� �ccwwr�r Expiration Date: 09/13/16 • ' Approval Date: 09/15/11 Page 8 of 8 gHQ Miami shores � * Building Department o�, 11111M 10050 N.E.2nd Avenue `ny� Miami Shores, Florida 33138 ,�me Tel: (305) 795.2204 LpRipl'► Fax: (305) 756.8972 August 12, 2013 Permit No: RF13-1821 Building Critique— Sved Ashraf 1. 1) Provide a copy of roofing contractor's license attached to the incorporation. 2. 2) List the license number on the application. Plan review is not complete,when all Items above are corrected,we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re-submittal drawings. a o y M Village Miami hores u. allot Building Department . .� 10050 N.E.2nd Avenue Miami Shores, Florida 33138 ,ye ,� Tel: (305) 795.2204 1pR1UP► Fax: (305) 756.8972 August 12, 2013 Permit No: RF13-1821 Building Critique— Sved Ashraf 1. 1) Provide a copy of roofing contractor's license attached to the incorporation. 2. 2) List the license number on the application. Plan review is not complete, when all Items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and Include one set of voided sheets in the re-submittal drawings.