Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
EL-13-1582
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-201832 Permit Number: EL-7-13-1582 Scheduled Inspection Date: October 23, 2013 Permit Type: Electrical - Residential Inspector: Devaney, Michael Inspection Type: Final Owner: LIBONATTI, BRUNO AND ALEXANDRA Work Classification: Addition Job Address: 10343 NE 6 Avenue Miami Shores, FL 33138-2047 Phone Number Parcel Number 1122310120210 Project: <NONE> Contractor: EAB EGINEERING SERVICES Phone: (786)239-1808 Building Department Comments EXSITINGN ELECTRICAL SERVICE UPGRADE FROM 150 Infractio Passed comments TO 200 AMPS INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. October 22,2013 For Inspections please call: (305)762-4949 Page 22 of 22 t Miami. Shores Village �� F ,:; Building Department JUL 1 5 2013 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795.2204 Fag: (305)756.8972 ` INSPECTION'S PHONE NUMBER: (305)762.4949 1 FBC 2010 BUILDING Permit No. PERMIT APPLICATION Master Permit No. U 3 " I's F59-% Permit Type: Electrical JOB ADDRESS: V*" Nl�- (0 AVIAU V City: Miami Shores County: Miami Dade Folio/Parcel#: 11 ° 'Z°L N - 0 12•®a•j 0 Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): 10su n o L I Y2on4'it1 Phone#: Address: 1®3" 14f, WA VO t.& City: MIAMI 5 110 re-5 State: Tenant/Lessee Name: m 1 Phone#: Email: I NIA CONTRACTOR:Company Name: EAD snatnee-nnA SVcr, Phone#: —1&0'2'3'q Address: - I?55, -5W 09 5 .), 4Z2- City: M l&I m 1 State: f:q— Zip: ✓315(0 Qualifier Name: list trial IZ A® 134 YY t°1ty Phone#: State Certification or Registration#: eC, 1 ?00 0 r✓" 11 ?) Certificate of Competency#: NIA Contact Phone#: _100- 231' 1 008 Email Address: DESIGNER:Architect/Engineer: r_-d Uai 1a V0 p5a1 ry-&ro Phone#: zail • I a U Value of Work for this Permit:$ l 1 V2'O®-0® Square/Linear Footage of Work: N1 A Type of Work: ❑Address *Iteration ❑New ;<Repair/Replace ❑Demolition Description of Work: e j tom i caI Seii'ViGc! OF A IN from !r:�D -to 200 amn05 Submittal Fee$�cx Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ �/�� TOTAL FEE NOW DUE$ Vim(./110 f � Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspectiojxOwnerorAgent pproved9 pection fee will be charged. Signature Signature Contractor The foregoing instrument was acknowledged before me this 12 The foregoing instrument was acknowledged before me this day of 20 13,by 0RUM) I,l l l day of U!: ,20 a by Ed 1400') I311 T-5- who is Prsonally kno to me or who has produced who is rsonally known o me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: GUARDIA Sign: li -State of Florida Sign: �l• _ . • , � pires Dec 2 S1 a`=. . o lic F of da Print: Print: •« My 14 M Commission Expires: 40,1,1.o°', Bonded Through National Notary Assn. M Commis n ���� Commission#EE 51872 Y P Y Bonded Through National Notary Assn. 2Cv0� APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15109) goREs 5c.193a G Miami shores Village � 1x4 Building Department lg, NJ 111111M 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 LpR�Up* Fax: (305) 756.8972 July 16, 2013 Permit No: EL13-1582 Electrical Critique— Michael Devaney 1. Plan showes a 150 amp. subfeed connected to a 200 amp. over currant device.Protect subfeed conductoer or show that the length of conductors is less than 25 feet. Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re-submittal drawings. y�►oR�s TNlC.1932 N". Miami Shores Village i,- .�� Building Department RID 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fait: (305) 756.8972 RECEIPT PERMIT# ` 13 / SS2ATE: 0 Jq f I, A re e ( rte/OL r t6 contractor (NAME) • Owner •Architect Picked up 2 sets of plans and (other) Address: /C2 3 q '�> NE en,ar From the building department on this date in order to have corrections done to plans And/or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: P ignature) PERMIT CLERK INITIAL: RESUBMITTED DATE: 2511 PERMIT CLERK INITIAL: .EAR ELECTRICAL NOTES SITE INVESTIGATION NOTE 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT Engineering FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED, Services,Inc. DRAWINGS. BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND 2) COMPLY WITH THE N.E.C. AND FLORIDA BUILDING CODE 2010. FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND re55 sw se sr,SUITE 422 ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE MIAMI•FL.33,55 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK PH:UN 239-IWB 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT, INVOLVES NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL ` 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE (L ALL EXISTING CONDITIONS. PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND 0 o ° 9) ALL CABLE SHALL BE COPPER. RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. 0 10) INDOOR CONDUITS SHALL BE EMT (THE CONTRACTOR CAN USE W "00� ,h ROMEX AS ALTERNATIVE WIRING WHEN ALLOWED BY FBC & NEC 2010.) V " z 11) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. ,n 3 W no 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. Q UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM s COVER SHALL BE 24 INCHES. SCOPE WORK Lu g Z - EXISTING 150 AMP ELECTRICAL SERVICE TO 200 AMP w (120/240,1 PH) WITH TWO MAINS OF 150 AMP & 70 AMP o RESPECTIVELY, BE GROUPED LESS THAN 10 FEET WITH ELECTRICAL METER. a 1D 3—#210 THWN Cu IN 2" C 0 zz 3-#6 THWN Cu + #8 G Cu IN 3/4" C e NOTES a ® 3-#1/0 THWN Cu + #6 G Cu IN 1-1/2" C E- EXISTING DIVICE LOAD CALCULATIONS An"a. m N- NEW DIVICE R wso amissi' ! < 5O 3-#1/0 THWN Cu + #6 G Cu IN 1-1/2" C ER- EXISTING DIVICE TO BE RELOCATED 05.25.1319T ISSUE GEN.LIGHTING:2,152 SF x 3 VA/SF= 6,456 VA z © 2—#4 THWN + #8 THWN NEUTRAL + #8 G Cu IN 3/4" C w +3000 VA(SA)+1500 VA(L)=10,956VA ? U EXTERIOR BUILDING w NEW METER GEN.APPLIANCES&WATER HEATER= 31,340 VA V) CANS C0 z 200 AMPS SUB-TOTAL= 42,296 VA " z G) f N © POOL FILTER PUMP 2HP AT 100 9/= 2,880 VA 1 N E w I N POOL PANEL-"A' POOL LIGHT,AND GFCIA AT 100% 480 VA m O MAIN MAIN SUBPANEL 120/240 V 150 A 120//240 V 150 A SUB TOTAL=3,260 VA ` 1rrrr o METE N 7A 150 A 22�004AIC 1 66 A3 W 1 PH, 3 W TOTAL= 45,556 VA ,,� ••. • • �, 120 240 V MILO MLO e �� •� • I�io 0 022, 00 AIC ® FIRST 10 KW AT 100/o= 10,060 VA : Y • i, • M O 5 E REMAINDER 35,556 VA Q 40%= 14,223 VA +(� A/C OR HEATING AT 100 X= 12,000 VA + �: Nd • GROUND LEVEL ��• o TOTAL DEMAND= 36,223 VA ; ! " * 4 10'-0" DEEP GROUNDING 36,223 VA 0 2401120 VOLTS=151 AMPS ROD '$� 9r) ;• cJ F ai 1 w D - 5/8" DIAMETER I,± l'� - -- ----ij �• �� 10 6' APART MINIMUM Bt(!i �iTPd SPC '. I�Q 1�g c�n�a••.•• ,�� N ELECTRICAL RISER DIAGRAM - — �y�, •.••••••., N.T.S. APPROVED Sy ELECTRICAL PLAN 70N INN DEPT SCAM Is,1W BLDG DEP �2y�Gf�,�c�� DRAWING Na SUBJECT TO COMPLIANCE W1TI i All F! fP'_I iA!