Loading...
PLC-12-2407 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL �- Phone: (305)795-2204 Fax: (305)756-8972 T)S ,; _ 20 '9 Inspection Number: INSP-199361 Permit Number: PLC-12-12-2407 Scheduled Inspection Date: October 16,2013 Permit Type: Plumbing - Commercial Inspector: Diaz,Osvaldo Inspection Type: Final Owner: , Work Classification: Addition/Alteration Job Address:160 NE 99 Street Miami Shores, FL 33138- Phone Number (305)864-8885 Parcel Number 1132060132250 Project: <NONE> Contractor: RAINBOW ENTERPRISES Phone: (305)688-9288 Building Department Comments DRAINAGE ONLY Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-198172. SIGNED AND SEALED WITH LETTER FROM AN ENGINNEER ACKNOWLEDGING RESPONSIBILITY FOR WORK ALONG WITH PICTURES SIGNED AND SEALED WITH LETTER ACCEPTING RESPONSIBILITY Failed ❑ FOR WORK ALONG WITH PICTURES Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. October 15,2013 For Inspections please call: (305)762-4949 Page 16 of 48 Inspection History Miami Shores Village 10050 N.E.2nd Avenue Miami Shores FL 33138.0000 Phone: (306)795-2204 Fax.(305)756-8972 11 00 Project <NONE> Owner: CENTER LLC MIAMI SHORES Phone: (306)8648885 Job Address: 160 NE 99 Street Parcel: 1132060132250 Miami Shores,FL 33138- Block Lot: Scheduled [asp# Inspection Type Inspection Status Inspector Date Completed 01101/2999 INSP-183262 Top Out NONE Default Inspector Not Complete 01/0112999 INSP 183266 Re Pipe NONE Default Inspector Not Complete 0110112999 INSP-183263 Main Drain NONE Default Inspector Not Complete 0110112999 INSP483260 Underground NONE Default Inspector Not Complete 01/0112999 INSP-183267 Heater NONE Default Inspector Not Complete 01/01/2999 INSP-183265 Water Service NONE Default Inspector Not Complete 01/0112999 INSP483268 Final NONE Default Inspector Not Complete 01101/2999 INSP-183261 Water Main NONE Default Inspector Not Complete 0110112999 INSP-183264 Lavatory NONE Default Inspector Not Complete 03111/2013 INSP-186964 Rough CANCELLED Rafael Hernandez 3/13/2013 01/0112999 INSP-191921 Rough NONE Rafael Hernandez Not Complete CREATED AS REINSPECTION FOR INSP-186964. 06/06/2013 INSP491922 Rough APPROVED Rafael Hernandez 616/2013 Tuesday,June 11,2013 Page 1 of 2 �� � � ��8 R Village Miami Shores V a e g DEC 9 Building Department I 10050 N.E.2nd Avenue 1Viraxm Shores Florida 33138 - �-- - _- ----°- Tel:(305)795.2204 Fax:(305)756:8972 INSPECTION'S PHONE NUMBER:(305)762.4949 FBC 20 `® BUILDING Permit No. PERMIT APPLICATION Master Permit No. �'°� �:Ri Permit Type: PLUMBING JOB ADDRESS: 100�N E City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: `1® 3 Ryro ® 13 - 6z ol�-O Is the Building Historically Designated:Yes NO Flood Zone: OWNER:Name(Fee Simple Titleholder): Ackm 1 s6 (gy �•r ®'° Phone#: Address: (9e0 7/-"r t 309 City: ®dt�l1 QC") State: Tenant/L.essee Name: Phone#: Email: ) ONTRACTOR:Comp y Name: Phone#: 27 Address: Z 1& L City: ® State: q1 Zip: Qualifier ame: lIC n Phone#: State Certification or Registration#: C of Competency Contact Phone#: Email Address: �l�t�� C) DESIGNER:Architect/Engineer: Phone#: Value of Work for this Permit:$ 6 CL°�CD_ CC-"3 Square/Linear Footage of Work: Type of Work: ❑Address ❑Alteration ONew ORepair/Replace ❑Demolition Description of Work:_ ��-�PJ�� , C--, L-� 1• Submittal Fee$ Permit Fee$ :2 /C9 CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE 9� y,r ti Bonding Company's Name(if applicable) Bonding Company's Address City State zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation 1.as commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of su osted notice, the inspection will not be approved and a remspe 'on fee will be charged. Signature Signature Owner or Wgent T4 Co tract r The foregoing instrument was acknowledged before me this The foregoing instrument was knowledged before me this�� day of � 20 b M 1 C', da of f� ,20�. ,b ` A I CH Y � -�- Y Y Y who is ersonally known'to a or who has produced who is personally known to me or who has produced ��Q As identification and who did take an oath. as identification and who diq tatty du,%�h. NOTARY PUBLIC: NOTARY PUBLIC: ��` '\�..O S°�°'�•, Sign: Sign: Print: C I M®� Print: My Commission Expires: Commission Expires: ✓s,�� C�i aA� .. S`�\\`\�`� °,�bY•�'��o OBIT MIMOUN Commission# 946 ^ sk mission x p i re s a sa ,k,k says safe s��k ,k�a�a �a �e,ks«sa :x ,xx� x� x, ecember 14, 2013 APPROVED BY Examiner Zoning Structural Review Clerk (Revised3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) r K EAlt Trench Lenght Miami Shores Parking 8/23/2012 160 NE 99 Street Miami Shores, FL E2affilka-tion Trench Lenath Calculation Impervious area= 7,000 square feet or 0.16 acres The 5 year, 1 day storm to be contained within drainage system=6.5 inches K= 0.00012 Pipe diameter= 1.25' Trench depth= 15.00' Trench width= 4.00' H2(depth to water table) = 6.50' Du(non-saturated trench depth)= 6.50' Ds (saturated trench depth)= 8.50' Volume to be exfiltrated = 1.04 AC-IN (6.5 inches X 0.16 acres) L= 1.04 0.00012x [(6.5x4)+(2x6.5x6.5)-(6.5y+(2x6.5x8.5)]+ [(.000139x4x6.5] Length required= 41.49' Length of trench provided=50 L.F. Calculation prepared by: �®C H0`"fe ® 41 2 3 2�1 o Sus olland, P.E. ® u ® a Lic. No.41831 0 .. STATE OF ®°�4U� Page 1 s Phone 854-784-2941 edera ,-1 800-848-1919 `t Fax 954-784-7875 &T€STIING250013thftPOMPM060ackk3mg fe,il-eng.com USUAL OPEN - HOLE TEST DATE, 8/16/12 ORDER#: 12-1790 CLIENT: Barr Architectural Studio PROJECT: Proposed:Drainage ADDRESS: 160 NE 99`h Street Miami Shores FL LOCATION: See Attach Site Sketch EX-1.. DIAMETER OF HOLE: 8 inches DEPTH OF HOLE: 15 feet TESTED BY: SYSL REPORTED TO: Client Gallons/Minutes Elapsed Time in Minutes 13 1 13 2 12 3 11 4 10 5 10 10' 10 20 10 30 Hydraulic Conductivity: K = 1.2 x 10-4 CFS4-e FT.HEAD Subsurface Investigation Depth Below Ground Surface Soil Description 0'0"-0'6" Topsoil&Vegetation 016"- lf6t' Dark Brown Sand 116"--316" Light Gray Sand 3'6"-710" Pale Brown Sand w/Borne Rock 77_151011 Light Orangish Brown Sand Water table elevation: 97" Below Existing Ground Swfaoe- Keith LeBlanc,P.E. V�dera� a in ring,A Testing.. FTv�aida R��:`�Iii�X94' tM 11111nt++it Construction Material Army Corp American Concrete Miami Dade Florida Department Engineering Council of Engineers Institute County of Transportation a --R � r NE 99th.Street R.O.W. Sidi wrallc 1 � EX-1 Vacant Vacant Lot Lot Q . Soil Boring Location (Not to Scale) Proposed Drainage 160 NE 99th Street f�liami Shores, Florida