Loading...
RF-13-530 c � Miami Shores Village Building Department MAR 18 2413 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795.2204 Fax:(305)756.8972=' �- INSPECTION'S PHONE NUMBER:(305)762.4949 —L,l {F��BC 20 B G r Permit No. F I- ° S PERMIT APPLICATION Master Permit No.� 2 " 1� Permit Type: BUILDING ROOFING JOB ADDRESS: v ''' f, lo, fe- S City: Mi hor i_9 County d_ Miami Dade Zip: �. Folio/Parcel#-- 0/4,�r® Is the Buil gnated:Yes T-O Flood Zone: OWNER:Name(Fee Simple Titleholder): Phone#: q�- Address: 4 ®®!? A4-,-g ,��� -5, City: 42L 4__-W edge'5 State: 0=/ Zip: TenandLessee Name: Phone#: Email: CONTRACTOR:Company Name: t TmqV4^ ad 1 h Phone#: �O -^� 17-51 Address: () City: °-,0 tate: L(° Zip: 3:: 60 Qualifier Name: w�tcfes° ca® Phone#: State Certification or Registration#: Certificate of Competency#: Contact Phone#: Email Address: U08 M 6 G� DESIGNER:ArchitectlEngineen Pho I:� yF. � Y Value of Work for this Permit:$1 • QO Sq Fo Z- 1 i �. Type of Work: ❑Addition DAlteration J1gfN w ,, ' ORe /Replace ODemolition Description of Work: `lif-to Ub[ � Color thru tile: ���x��xm���������sma�s��a��aax�ms������Feessx�����a��sxxxa�sx�����������x�a����a•�am��ex Submittal Fee$ ��• ® Permit Fee$ _J CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ ' ��1.�`V ��L 1 l� � � � � 0(��(t{'�c��L A . - P Bonding Company's Name(if applicable) Bonding Company's Address City State zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL.WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:" Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued_ In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. C Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this e The foregoing instrument was acknowledged before me this day of ,201 ,by ""�- � - day of;� 1 ,20 -by `� L.I rQ , who is ep rsonally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: ' Print: :o�',IV,-Ana Elizabeth Raiszadeh Print:c 895323 I e My Commission Expires: •,,� oo�EXPIRES: SEP.22,2013 My Commission Expir 4 COMMISSION#DD895323 WWw.AARONNoTARycom �;� •• o°.�EXPIRES: SEP.22,2013 its www.AARONNoTARy.com APPROVED BY f ? r ` Plans Examiner zoning Structural Review Clerk (Revised 3t12/2012)(Revised 07/10/07)(Revised 06110t2009)(Revised 3/15109) d� STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 1940 NORTH TALLAHASSEE FL T STRFLT32399-0783 CARO, ROGER ALBERTO MIAMI ROOFING AND WEATHERPROOFING INC 2600 S UNIVERSITY DR #206 DAVIE FL 33328 fth Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. IBS . 8 Our professionals and businesses range from architects to yacht brokers,from F :; boxers to barbeque restaurants,and they keep Florida's economy strong. �� Every day we work to improve the way we do business in order to serve you bette - For information about our services,please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that " -RO impact you,subscribe to department newsletters and learn more about the laI}Pi R � ; Department's initiatives. Our mission at the Department is:License Efficiently,Regulate Fairly.We Thank you for oing business better Florida and congratulations on your new license DETACH HERE 1.9 01 ZM I W, °• °• A .t� DR ` : i2 AR3FT� G .TO °00�1'STB.�fCT�ON �' 'C`k3Titf L�CENB� s kl Tt RoF}4t9G *7N`g' i1 de a Zp� oVXs ons `.cif shag ]Eal �t cae ADS It, Oal _ IT : R000 0 AM .NSA.MEi;PRQ Ap RIf. ��T� L ,St3P> G'€T�4TE�NOR ��CR `AI�Y nigPi AY AS RFOt iiRFD 9V i AW. t I I FIRST-CLASS U.S POSTAGE PAID FL PEFUNT NO.231 576941-0 TIM IS NOT A BILL—DO N XrPAv RENEWAL BUSWESS NAM I LOCATION RECE3P'FM 601606-7 MIAMI ROOFING & WEATHER PROOFING STATE# CCCUSS208 INC 20801 SAN SIMEON WAY 202 33179 UNIN DADE COUNTY OWNER MIAMI ROOFING & WEATHER PROO INC WORKERS X196 SPEoCIAALTY BUILDING CONTRACTOR 1 TM IS ONLY A LOCAL BUSUGM TAX RECEIPT:iT DOER NOT POW THE N8Z17 TO VIOLATE ANY ED0.STTNCi REGULATORY OR Zwom C DO LAS OF THE DO NOT FORWARD CNYY OR t7TU£4. MR DOES IT EX 3wr Tm PERM ON UCENSE REMBRED BY LAW.TM IS Tg CW MIAMI ROOFING & WEATHER PROOFING mm ROGER A CARO PRES PA 2600 S UNIVERSITY DR #206 COLLECTClh DAVIE FL 33328 09/25/2012 0d�2260027001 Y OVdyy075.0@ t!!/ lfldtdl��btdd•1��1t03ddf1�/t}lldli88l�la d!&llttJid3i�lF! 1 SEE OTHER SIDE e ti CERTIFICATE OF LIABILITY INSURANCE --° 3 TAs C@R4=ff W i>1WL=At A MTR QF M ►Vl* PRODa i,711t�.Y mm Cii>6 w MGM iNtfiil Tl�ATE 4M Jog ft"scut lIO R.Tf�s t tTIF[CATR�iMM�i�T lNY .E OR rovow"",FL 33467 llA1C Phow(WI) V f228 FM{S61}++F9Z-�t18 VUR NVOMM Ctivoulf�l$ WMARM A: �tii soft insurance co. "OUN D rooming&WlS� Mm0 20WI SM SIMEON WAY#202 M MIAMI,R..33179 WOMMONMR covi R a" 01SUM P THE ROLn"C}F voww"a—m'w&sI aw"TO TM€iN OWD w MM"bw FOR TTY MICY mmon t61BlC wo. ANY�ZEt2lAFlEi1�!!iT,TERIA CJR 6CMNORtOI�t OF ANY C�OR OTHER DOCI�N't'YYI'T'fi R6�' '€CT TO WF�ri 1F�C€RT�RTE AiJIY qE Iii!QR MAY PERTAN.THE MAN=AFFOMED BY T!M FOL9*9 DE8CRWD MERgn IS 8U 90T TO ALL THE TOM.CC-L AND CQMXrVS OF SIGN POLICIES.A4s'sM(;AT€llA rra SM M MAY NAVE eMm RELIC ED BY PAID CLARIS. ROR /iCLTL111t11! LMII TY7P"f CW NGUR WGM POLICY NuMeEN EAGM oCC MENCE SLOW= t GENERAL U►if UTY JINTED lj1Ci0,0i1ti ► COM MERCM L CORAL--PALtTr {)9-2245 01-0 6-13 p -36-14 0a ow yVn ii C© cLAa iOE W A ❑ fl c AOMGATE �Oif0,f7�3 GEN'L AGOMOATE ULI T APPLIES FW- ❑ PoUry Q PRO1fCT 13 L4HG C AUT+ Li E AsulY (NdBit D LIMIT (0 *W AUTO 10 ALL CIATM AUTO$ softy INJURY (� 10 SCMDULD AVTOS Q Hwtm Auros BODILY M �❑ WM OWHED MAMS ww wwww4 PROPERTY AUTO ONLY-EA ACC ' GAPAQE L1AALITY EI Q AW AUTO AG6 BACII OCCURREWE LIABBI7'Y O O (3 M MADE J4£T3ltdl3ME D OSDUCTME v Lur BTU �MALITY If.L EACH ACCOW AW PROPRQTOR t PARTNQR/EXECU'rIME S.L.t •FA YM�t.OY€E OFFi.'Istf MAR EXC�.Uf1B0? #yns�o[abt under fir €.L COSAW-POWY Lwr OVSKM PR CRHER M L& M RO0RN6 AND WEATt fKXW is PRORU ooa*Y suff=mdhW of properLyW kOWunWad rounn numerbb and attws W re-roof o f ar in part DUPA-MM OF PROJEC17- app=&j0tdy is worifgdwp,Weeder P - CER'i'ik'f�'•A'l'E Hi1.tTER C1i�lt,�Lt.AT101it Miami Dade Building Dept. MMKWW"Top Tim Man U P Lsm s B IC T TiloR6Mfl67f 0l,TNB OWAM"LL "=T*MAA. II805 S.W. 2f"'Street DAYS TI��� TO THE LiPT,MiTF no so SHALL Mama llo+ �LE11/XiTY o► r ttfY 'RSA Miami, Fl 33175 mAnKW IOli�AOd 786-315-2000 M ACORD 60WO CATION"a /iCORO 29 Cif -a CERTIFICATE OF L[ABIUTY tNSURA►NCE O1'042013 Ma C) J►W.M> I AS A HRT MR OF ATM Fr:. of Kiss ic Ia' �X AM no gMM Upon 7M CMIW CA'TE 3asr " i HOU313L Ta 1 ATE BoE NOT AMEN MrMID OR BTTMP S3Ia1 BELOW.�i $ C AlERTE aZ_a.. TX 75234 -.3001 5532-5.36 !3�2' '15-395 VAURM AFFORD=CACE Sag: ;_3 2• 4C4-4450 L � C as R--,per'.y 3d, Ca m—,t1 i I 2=ar-s =� ?7GF �-o Sa ss° n g =,- ar a 33152 NSLRER Ek lU TER E CONERAGM THEPOUCESOF�RAE�L�3T T'�-�F�1� 1 W"fE3EQ "[E!!AY BEISSM OR AM Tai 4 cR CCMXnCHO�F AM Ck 'Mt Oil APF2 0�"'{�F�i llltW P> -*ESA BY 4t PWi�S � iC 1 TtE F s O P©UM&AGGREMELWMSMM y HOWESEEMSEMCEDSYPAWCLAM lm sRHL tA'9D71 L8li'S POLMY BEIIMUIL lY186N'l ;:REg+.'��Ej 3 t .. tiPH6-fi'Y �3�tP��pes3ik g '. . S "R YpL3aPS�I2 S - aim S [E DSLMT S 'ml AV �n8:8itF1R" S HIZDA31'-OS � �t-�?�/l�tTh+JdTS PREPERr-a 3 CAMMOLUL85-My FA-1 CC � R g . t°t.t§a'3ii t S aEcLqz S $ a a aq aas 3 X5313 ; f �'?Ul� .�c[ a S �IttQ 4 � -I�itE� g 1fat2l341G`C p ;�S Tr ?.. BLr . . io Do --P3 C3S 'T'CL 't�2i-�4'�-3ii a trJ-F =s:�tha 3 ' S -M53 3i`fa ='r 19 AiOi L�6_Lt���� 3�s7E�r-+...� �a� _.� Y i5 -`a s:o- z.e3e�� t1m Policy =or �`r--- ie� t from f3 warkars C ans----3�T 5 mwluy--rs i L ty my Sts.-FL r oa x=r Imc- eFarsr: ssalttr+&E rs>s£rltt� MMI-DADE BUILDING DEPT. . � ] s IA 11805 S.W.26 STREET MIAMI,FL 33175 Muse In commmom umoffr:F w tw wm matmom as ass am — . ACS ZSS X197} r , h. Jr Sho I 2 FAPPR01V 0 BY DATC ZONING DEPT HIGH-VELOCITY HURRICANE ZONES BLDG DEPT -J,3j ECT i 0 Ct1P,l=l,',F'NCE WI FH All FEDERAL • �yv C`:L, d i f I �'r\PdL PN-CULATIONS - Florida 4116 g Oode Edfon 2010 — Hi h Wlodq Hurricane Zone Uniform Permit Appkation Form. Section A (General Information) ' Master Permit No. Process No. Contractor's Name AdjW1 'P15 11 ' Job Address ROOF CATEGORY Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles 5 � ❑ Prescriptive BUR-RAS 160 ; ■ 1 • ROOF TYPE • k • New Roof ❑ Reroofing ❑ Recovering ❑ Repair,``;`, ❑ enance ROOF SYSTEM INFORMATION Low Slope Roof Area{S Steep Sloped Roof Area(SF) Total(SF) `c ` Section a lRoof Plant • S t \�R ?tai: Illustrate all levels and sections, roof drains, scuppers, overflow ' � ppe , • scu e ap ,, an"verflow drains. Include dimensions of sections and levels clear! iden ' .'." Imensions of elevated pressure zones and location of parapets. y I J ■ ' ■ � �, .-� 1 i-- ■ T. t Lf ■ • ■ ■ 2010 FLORIDA BUILDING CODE—RESIDENTIAL AA,,, Section C r s t t Miaml-Dade County HVHZ Electronic Roof Permit Form Section C Page(Loan Slope Roof Systems) "Delivering Excellence Every Day" Fill in the specific roof assembly components.If a component is not required,Insert not applicable(n/a)in the text box. ROOF SYSTEM{MANUFACTURER: I GAF MC Top Ply. GAF Mineral Surfaced Capsheet Product Approval (NOA); 07-1219.09 System Type; `Top Ply Fastening/Bonding Material: Wind Uplift Pressures,From RAS 128 or Sealed Calculations: I Type 4 Asphalt (P1) Field: 42.8 psi Surfacing:I n/a SINGLE PLY MEMBRANE: (132) Perimeters: 71.7 psi Single Ply Manufacturer/Type: (P3)Comers: 108.0 psi n/a Maximum Design Pressure From NOA 52.5 pg{ Single Ply sheet Width: Na °112 Sheet Width: n/a ° Roof Slope: 9/4 °:12 Roof Mean Height: 14 ft. No.of Single Ply 112 sheets:E Parapet Walls: ❑No ®Yes Parapet wall Height: 1.5_ ft. Single Ply Membrane Fastening/Bonding Material: n/a Deck Type: —5/8°Plywood- . OFASTENER SPACING FOR BASESHEET ATTACHMENT Support Spacing: n/a °o/c ❑SINGLE PLY MEMBRANE ATTACHMENT n/a Altemate Existing Roofk Tom' 1.Field:L°o1c @ Laps&El rows 9 °o/c n/a 2.Perimeter. °o1c @ Laps&El rows °o% Fire Barrier. n1a 3.Comer.El°o%@ Laps&El rows °o% Vapor Barrier. r NUMBER OF FASTENERS PER INSULATION BOARD: n/a 1. Field: __ 2. Perimeter n a 3. Comer. n a- - - - - - Anchor Sheet: Insulation Fastener Type: 75#Glass Base n/a Anchor Sheet Fastener/Bonding Material: - 1-1/4°RS Coil 1-5/8°Tincaps WOOD NAILER TYPE AND SIZE: Insulation Base Layer Size&Thickness: - 1 2.0°Polylsocyanurate 4x4 Wood Nailer Fastener Type and Spacing: Insulation Base Layer Fastener/Bonding Material: n/a Type 4 Asphalt EDGE&COPING METAL SIZES: Insulation Top Layer Size&Thickness: Edge Metal Material: ELECT EDGE METAL MATERIAL- n/a Edge Size:I—SELECT EDGE METAL WEIGHT OR THICKNESS- _-__- Insulation Top Layer Fastener/Bonding Material: SELECT EDGE METAL HOOK STRIP SIZE— Hook Strip Size: — n/a Edge Metal Alta men Base Sheet(s)&No.of Ply(s): n/a 1 ply GAF Perforated Stratavent Base Sheet Fastener/Bonding Material: Coping Material:I—SELECT PARAPET WALL COPING — Type 4 Asphalt Coping Size: -SELECT COPING METAL SIZE OR THICKNESS— Ply Sheet(s)&No.of Ply(s): Hook Strip Size: -SELECT COPING METAL HOOK STRIP SIZE- 2 plies GAF Ply IV Parapet Coping Metal Attachment Ply Sheet Fastener/Bonding Material n/a Type 4 Asphalt - Parapet WaU lncolated Nailable Deck Miami-Dade County HVHZ Electronic Roof Permit Form mom 'Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: W - ,--° Concrete wall { ElWomeric meant tooled to facillitate water run-off Optional compressMe Parapet wall height: 14 % Elastomeric sealant Metal counterflashing mech Roof Mean Height: 1 5 % Base Flashin . attached 8°o/c w/washer' g' rea<tops of base flashing wt GAF Ruberoid SBS White comptable material Surfacing: - � 4 --` n/a Termination bar mach. Top Ply: _ attached 6"o/C r' 1 GAF Mineral Surfaced Capsheet ION Reid plies turned tip wall Inter Ply Sheet: 2 plies GAF Ply IV • Base flashing min. Base Sheet: 8"aboae finished roof 1 ply GAF Perforated Stratavent aX s• ,. + t Mutiple plies of bulft up Top Layer of Insulation: • v roofing n/a .�.,. Top Layer of Insulation Base Layer of Insulation: !' 2.0 Polyisocyanurate Base Layer of Instdation �. Anchor Sheet: Anchor Sheet G5#Glass Base Roof Deck Type: Roof Deck 5/8"Plywood min. - Cant strip MM F�DAD MIAMI-DADE COUNTY,FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE(BCCO) 140 WEST FLAGLER STREET,SUITE I603 PRODUCT CONTROL DIVISION MIAMI,FLORIDA 33130-1563 (305)375-2901 FAX(305)375-2908 NOTICE OF ACCEPTANCE NOA GAF Material Corporation. 1361 Alps Road Wayne,NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed by the BCCO and accepted by the Building Cade and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been Bled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. 1f any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.03-0501.05 and consists of pages 1 thro gh 19. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 07-1219.09 Expiration Date: 11/04/13 IAMIDADECi u,NTYM Approval Date: 03/20/08 Page 1 of 19 i ROOFING SYSTEM APPROVAL Category Roofing Sub-Category: BUR Deck Tyne: Wood Maximum Design Pressure -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Pr duct Dimensions Specification Description Leak BusterTM MatrixTM 3, 5,55 gallons ASTM D 41 Asphalt concrete primer used to promote 307 Premium Asphalt adhesion of asphalt in built-up roofing. Primer GAF Mineral ShieldTM 60& 100 lb.bags ASTM D 1863 Granules for surfacing of exposed asphalt, Granules cold process cement or emulsion. GAF Mineral ShicldTM Granules shall be used for flashing applications only. Leak BusterTM MatrixTM 5 gallons ASTM 1227 Surface coating for smooth surfaced roofs. 305 Fibered Asphalt Emulsion Leak Busteirm MatrixTM 1,5 gallons ASTM D 2824 Fibered aluminum coating. 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM 55 gallons Elastomeric roof coating. 322 Elastomeric Roof Coating LeakBusterTM MatrixTM 55 gallons Asphalt emulsion Fbered. Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 1,5 gallons ASTM D-4586 Refined asphalt blended with a mineral 204 WaYDry Roof ASTM D-3409 stabilizer and fibers. Permits adhesion to Cement wet and dry surfaces. RUBERUID*Modified 5 gallons ASTM D 4586 Fiber reinforced,polymer modified Flashing Bitumen Flashing cement Cement LeakBusterTM MatrixTM 5 gallons ASTM D 4586 Asphalt flashing Cement 201 Premium SBS Flashing Cement GAFGLAS*#75 39.37"(1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07-1219.09 MIA a uNTY Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 Test Product Product Dimensions Specification Description GAFGLAS®#80 39.37"(1 meter) ASTM D4601 Asphalt impregnated and coated,fiberglass ULTIMATM Base Sheet wide base sheet GAFGLASO 39.37"(1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt with Flex P1yTM 6 wide asphalt coating. GAFGLAS"Ply 4 39.37"(1 meter) ASTM D 2178 Type IV asphalt impregnated glass felt with wide asphalt coating. GAFQLAe Mineral 39.37"(1 meter) ASTM D 3909 Asphalt coated,glass fiber mat cap sheet Surfaced Cap Sheet wide surfaced with mineral granules. GAFGLAS® 39:37"(1 meter) ASTM D 3909 Asphalt coated,glass fiber mat cap sheet EnergyCapTM Mineral wide surfaced with mineral granules with factory Surfaced Cap Sheet applied layer of TOPCOAT EnergyCoteTM. GAFGLASO 39.37"(1 meter) ASTM D 4897 Fiberglass base sheet impregnated and STRATAVENT wide D 3672 coated on both sides with asphalt. Surfaced EliminatorTm Perforated on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS@ Flashing Various Asphalt coated glass fiber mat flashing sheet available in three sizes. GAFGLAS* 39.37"(1 meter) ASTM D 4897 Fiberglass base sheet impregnated and STRATAVENT wide D 3672 coated on both sides with asphalt. Surfaced EliminatorTM Nailable on the bottom side with mineral granules embedded in asphaltic coating. RUBEROO SBS 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with Heat-WeldTM Smooth wide polymer-modified asphalt and smooth surfaced. RUBEROO SBS 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with Heat-WeldTM Granule wide polymer modified asphalt and surfaced with mineral granules. RUBEROID®SBS 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with fire Heat-WeldTM 170 FR wide retardant polymer modified asphalt and surfaced with mineral granules. RUBEROO SBS 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with Heat-WeldTM PLUS wide polymer modified asphalt and surfaced with mineral granules. RUBEROID�SBS 1 meter(39.37") ASTM D-6164 Non-Woven Polyester mat coated with fire Heat-WeldTM PLUS FR wide retardant polymer modified asphalt and surfaced with mineral granules. RUBEROO SBS 1 meter(3937' ASTM D-6164 Non-Woven Polyester mat coated with Heat-WeldTM 25 wide polymer-modified asphalt and smooth surfaced. RUBEROID®Modified 39.3T'(1 meter) ASTM D4601, Premium glass fiber reinforced SBS Base Sheet wide Type II,UL modified base sheet Type G2 BUR NOA No.: 07-1219.09 MAMPIDNAWDE Expiration Date: 11/04/13 .. , Approval Date: 03120/08 Page 3 of 19 Test Product Product Dimensions Specification Description Leak BusterTM MatrixTM 5 gallons ASTM D2824, Non-Fbered aluminum pigmented,asphalt 302 Non Fibered Type 1 roof coating. Aluminum Roof Coating GAF Built-Up Roofing 100 lb.cartons, ASTM D312, Interply mopping and surfacing asphalt. Asphalt bulk Types I,111,111 and IV RUBEROID`e MOD 641b.kegs SEBS modified asphalt. Asphalt,Asphalt L& Asphalt P Leak BusterTM MatrhJm 5 gallons Surface coating for smooth surfaced and 602 mineral surfaced roofs. Leak BusterTM MatrixTM 5 gallons Surface coating for smooth surfaced and 715 mineral surfaced roofs. LeakBusterTM MatrixTM 2 gallons Surface coating for smooth surfaced and 531 WeatherCoteTM mineral surfaced roofs. SeamCoteTM 2, 5 gallons proprietary Elastomeric roofing membrane. . FireOutTM 5, 55 gallons Low VOC,fire barrier coating. VersaShield 350 sq ft. roll Non-Asphaltic Fiberglass-Based. Underlayment. VersaShiele FB-IS 350 sq ft.roll Non-Asphaltic Fiberglass-Based Underlayment. VersaShiele FB-2S 350 sq ft. roll Non-Asphaltic Fiberglass-Based Underlayment. TOPCOAT'FireShiele 5, 55 gallons ASTM D-412 Elastomeric roofing membrane MB ASTM D-21-96 ASTM D1475 ASTM E-1644 Leak BusterTM MatrixTM 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt 201 SBS Flashing Adhesive—Flashing Grade. Cement Leak BusterTM MatrixTM 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt . 102 SBS Adhesive Adhesive. Leak BusterTM MatrixTM 5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt 202 SBS Flashing Adhesive—Flashing Grade. Cement Leak BusterTM MatrixTM 5 gallons ASTM D4586 Standard Plastic Asphalt Roofing Cement 203 Plastic Roof Cement* Leak BusterTM Matr1xTM 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive NOA No.: 07-1219.09 w t-EMW uHrir Expiration Date: 11144113 .� � Approval Date: 43!20108 Page 5 of 19 Test Product Product Dimensions Specification Description Leak BusterTM MatrixTM 5 gallons ASTM D 2824 Fibered aluminum coating. 303 Fibered Aluminum Roof Coating Leak BusterTm MatrixTM 5 gallons ASTM D2824, Nan-fibered aluminum pigmented,asphalt 304 Non Fibered Type I roofcoating. Aluminum Roof Coating APPROVED INSULATIONS: Table 2 Product Name Product Description'. Manufacturer (With Current.NOA) EnergyGuardTM RA,RN Polyisocyanurate foam insulation BMCA Composite A&N Polyisocyanurate foam insulation with GAF Materials Corp. high density fiberboard or Permalite perlite insulation. EnergyGuardTM Fiberboard Fiberboard insulation. GAF Materials Corp. EnergyGuardTM Permalite Perlite insulation board. GAF Materials Corp. EnergyGuardTM GAFCANTTM Cut perlite board GAF Materials Corp.. EnergyGuardTM Permalite Recover Perlite recover board GAF Materials Corp. Board EnergyGuardTM Tapered Edge Strip Tapered perlite board GAF Materials Corp. EnergyGuardTM Perlite Perlite insulation board GAF Materials Corp. EnergyGuardTM High Density High density wood fiberboard insulation. GAF Materials Corp. Fiberboard EnergyGuardTM Composite Polyisocyanurate/wood fiberboard BMCA composite EnergyGuardTM Composite RA Polyisoeyanurate/wood.fiberboard BMCA composite Wood Fiber Wood fiber insulation board generic High Density Wood Fiberboard Wood fiber insulation board generic Perlite Insulation Perlite insulation board generic Dens Deck',Dens DecV Prime, Water resistant gypsum board G-P Gypsum Corp Dens Deck Dura GuardTM Structodek Wood fiber insulation board Knight Celotex SecurockTM Fiber reinforced roof board USG Corporation NOA No.: 07-1219.09 MIAMI aCOUNTY Expiration Date: 11/04/13 � Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-TecT*m 412 Standard, Insulation fastener and Various GAF Materials Corp. 414 and#15 extra Heavy Base Play fastener for Duty Fastener,Heavy steel,wood&concrete Duty Roofing Fastener decks. 2. Drill-TecTm ASAP Pre-assembled Drill- Various GAF Materials Corp. TecTM Fasteners and metal and plastic plates. 3. Drill-TecTM #12 or#14 Base sheet fastening Various GAF Materials Corp. Standard screws with assembly. AccuTrac Plate 4. Drill-ToJ'4 Galvalume Round Galvalume stress 3"and 3 %2" GAF Materials Corp. Plates plates. 5. Drill-TWm Round polypropylene 3"and 3 %2" GAF Materials Corp. Polypropylene Plates stress plates. 6. Drill-TecTM AccuTrac Square Galvalume 3"Square GAF Materials Corp. Plate coated steel plate. EVIDENCE SUBMITTED: Test Agencv Test Identifier Description Date Factory Mutual Research Corp. J.I.2B8A4.AM 4470 07.02.97 J.I.3B9Q1.-AM 4470 01.08.98 J.I.ODOA8.AM 4470 07.09.99 J.I.ODIA&AM 4470-TAS 114 07.29:94 J.I.OY9Q5.AM 4470-TAS 114 04.01.98 3029832 4470-TAS 114 05.11.07 PRI Asphalt Technologies,Inc. GAF-012-02-02 Physical Properties 11.06.01 GAF-020-02-01 ASTM D 4977 02.01.02 IkT of S.Fl. 02-005 TAS 114 01.18.02 02-014 TAS 114 03,22.02 NOA No,: 07-1219.09 MwMt�,4oecour�rr Expiration Date: 11/04/13 APPROVED Approval Date: 03/20/08 Page 7 of 19 APPROVED ASSEMBLIES Deck Type 1I: Wood,Insulated Deck Description: 19/32^or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened,all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. . Insulation Layer (Table 2) Insulation Fasteners Fastener (When applicable:Steel plate only=S,plastic plate only (Table 3) Density/fe =p) TM TM EnergyGuardTM,EnergyGuard Composite,EverGuard ISO;Ener Guard RA, g3' EnergyGuardTM RA Composite Minimum 1"thick NIA' N/A EnergyGuardTM High Density Wood Fiber,EnergyGuardTM Recover Board,Wood Fiber, Minimum V2"thick N/A N/A EnergyGuardTM Perlite Minimum%"thick N/A N/A Fiberglas(Min. '$1,6"thick) N/A NIA Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 Ibs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS90 STRATAVENr EliminatorTM Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating,VersaShield®Nan-Asphaltic Fiberglass-Based (optional) Underlayment or SecurockTM. Anchor sheet: GAFGLASO#80 ULTIMATM Base Sheet,STRATAVEN 0 Eliminatop•M Nailable,RUBEROID`s Modified Base Sheet,RUBEROIEP 20,RUBEROID Heat-WeldTM Smooth or RUBEROIDP Heat-WeldTM 25 base sheet mechanically fastened as described below; Fastening Options: GAFGLASG Ply 4,GAFGLAS®Flex PlyTM 6,GAFGLAS®#75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9"o.c.at the lap staggered and in two rows 12"o.c.in the field. (Maximum Design Pressure-45 psf,See General Limitation#7) NOA No.: 07-1219.09 M�,M� s uNrY Expiration Date: 11/04/13 1,,. Approval Date: 03/20/08 Page 8 of 19 Fastening Options: GAFGLAS*Ply 4,GAFGLAS*Flex P1yTM 6,GAFGLAS*#75 Base Sheet or any of above Anchor sheets attached to deck with Drill-Ted #12 standard,#14 or# 15 Screws and 3"Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12"o.c.in 3 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 12"o.c. in the field of the sheet. (Maximum Design Pressure,45 psf,See General Limitation#7) -GAFGLAS"Flex P1yTM 6,GAFGLAS#75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring$hank nails and tin caps at a. fastener spacing of 9"o.c.at the 4"lap staggered and in two rows 9"o.c.in the field. (Maximum Design Pressure--52.5 psf,See General Limitation#7) GAFGLAS*#80ULTIMATM,RUBEROID*20,RUBEROID*Mop Smooth,base sheet attached to deck with approved 1'/4"annular ring shank nails and inverted 3"steel plate at a fastener spacing of 9"o.c.at the 4"lap and in two rows staggered with a fastener spacing of 9"o.c.in the center of the membrane.. (Maximum Design Pressure—6lt psf,See General Limitation#7) GAFGLAS*#75 Base Sheet or any of above Anchor sheets attached to deck with Drill-Tedm#12 standard,#14 or# 15 Screws and 3"Drill-TecTM steel plate or Drill-TecTM AccuTrac PIates, 12"o.c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet. (Maximum Design Pressure—64 psf,See General Limitation#7) Any of above Anchor sheets attached to deck approved annular ring shank.nails and 3"inverted Drill-Teti"insulation plates at a fastener spacing of 9"o.c. at the 4"lap staggered in two rows 9"in the field. (Maximum Design Pressure—60 psf,See General Limitation#7) GAFGLAS#75 Base Sheet or any of above Anchor sheets attached to deck with Drill-TecTM#12 standard,#14 or# 15 Screws and 3"Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates,8"o.c.in 4 rows. -One row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c.in the field of the sheet. (Maximum Design Pressure—75 psf,See General Limitation#7) Base Sheet: (Optional)Install one ply of GAFGLAS*#75,GAFGLAS®#80 ULTIMATM Base Sheet,GAFGLAS®STRATAVENT*EliminatorTM Perforated, RU_BEROID*Modified Base Sheet,RUBEROID*Mop Smooth,RUBEROID® 20 RUBEROID*Heat-WeldTM Smooth or RUBEROID*Heat-WeldTM directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq,(see General Limitation#4). Ply Sheet: One or more plies GAFGLAS*PLY 4,GAFGLAS®Flex PlyrN 6 sheet,#80 Ultima,RUBEROID*Mop Smooth or RUBEROID*20 adhered-in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.ls . q NOA No.: 07-1219.09 MIAMMWECO M Expiration Date: 11/04/13 . Approval Date: 03/20/08 Page 9 of 19 Cap Sheet: (Optional) One ply of GAFGLASO Mineral Surfaced Cap Sheet or GAFGLASO EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROIDO 20 is top membrane)Install one of the following: 1. Gravel or slag applied at 400 lbs./sq.and 300 lbs./sq.respectively in a flood coat of approved asphalt at 60 lbsJsq.or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gglJsq. 2. GAFGLAe Mineral Surfaced Cap Sheet,GAFGLASO Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating,at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715,Leak BusterTM MatrixTM 322, TOPCOAT MB+,TOPCOAT®Fireshield Elastomeric Roofing Membrane,applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane,EnergyCotcV roof coating applied at 1 to 1.5 gal,/sq. 6. TOPCOAT'Surface Seal,TOPCOAT'Fireshiele SB Solvent based Etastomeric Roofing Membrane applied at Ito 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above. • NOA No.: 07-1219.09 CMIAMI-07ADT-PUNTYM Ex piration Date: 11/04/13 Approval Date: 03120/08 Page 10 of 19 I WOOD DECK SYSTEM Ln UTATIONS: I A slip sheet is required with PIy 4 and Flex P1ym 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4" Dens DeckTM or '/a" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LINIITAnoNS: 1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.lsq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 ps£ 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as fie ld tested,are below 2751bf.insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official, a revised fastener spacing,prepared,signed and sealed by a Florida Registered Engineer,Architect,or Registered Roof Consultant may be submitted. Said revised fasteners spacing shall utilize the withdrawal g Y p g resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner area shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared,signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of-perimeter nailers,metal profile,and/or flashing termination designs shall conform with Roofing Application Standard RAS 1 I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07-1219.09 Expiration Date: 11/04/13 MLAN- a Ecou n Approval Date: 03!20108 .• •t r Page 19 of 19 TGFU.R1306 Roofing Systems GAF MATERIALS CORP R1306 1361 ALPS RD WAYNE,NJ 07470 USA Class A ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet("GAFGLAS®#75 Base Sheet" or"Tri-Ply®#75 Base Sheet", or "GAFGLAS®#80 ULTIMA")is a suitable alternate for Type G1 asphalt glass fiber ply sheet("GAFGLAS® Ply 4" or"Tri-Ply®Ply 4",or"GAFGLAS®Ply 6")in the Class A,B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet"GAF Stratavent®EliminatorTM Venting Base Sheet(Perforated)"or"GAF Stratavent®EliminatorTM Venting Base Sheet(Mailable)."Perforated to be loose laid or mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet("GAFGLAS®#75 Base Sheet"or"Tri-Ply®#75 Base Sheet" or"GAFGLAS®#80 ULTIMA"or"GAF Stratavent®EliminatorTM Venting Base Sheet(Mailable)" may be substituted for Type G1 asphalt glass fiber ply sheet("GAFGLAS®Ply 4" or"Tri-Ply®Ply 4" or "GAFGLAS®Ply 6") as the nailed base ply in the following systems. 2.Deck: C-15/32 Incline: 2 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness. Ply Sheet:—Three or more plies Type G1 or"GAFGLAS®Ply 4" or"Tri-Ply®Ply 4" or "GAFGLAS®Ply 6". Cap Sheet:—One ply Type G3 "GAFGLAS®Mineral Surfaced Cap Sheet" or"Tri-Ply®Mineral Surfaced Cap Sheet "or "GAFGLAS®EnergyCapTM TM BUR Mineral Surfaced Cap Sheet." Copyright ( 2011 Underwriters Laboratories Inc. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,Designs and/or Listings(files)must be presented in their entirety and in a non-misleading manner,without any manipulation of the data(or drawings). 2. The statement"Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc."must appear adjacent to the extracted material. In addition,the reprinted material must include a copyright notice in the following format: "Copyright 0 2011 t SECTION R4402:13 HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of the section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner ant the contractor.The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics-Workmanshlp:the workmanship provisions of Section R4402 are for the purpose of Piro ding that the roof system meets the wind resistance and water instruction performance standards. Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be ailed in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs:Common roofs are those which have no visible delineation between neighboring uni i.e.,townhouses,condominiums,etc.) In buildings with common roofs,the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling:Exposed,open beam ceilings are where the underside of the roof decking can e sewed from below.The owner may wish to maintain the architectural appearance;therefore, roofing nail penetration of the underside of the decking may not be acceptable.This provides the option of maintaining the appearance. 5. Ponding water:The current roof system and/or deck of the building may not drain well and may ,,� Z:: cause water to pond(accumulate)in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water.Perimetededge wall or other roof extension may block this discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be reduced.It may be ben ial to consider additional venting which can result in extending the service life of the ro of. Owner/Agents Signature Date Contractor Signature Date Revised on 7/9/2009 LD � . f f � Miami shores Village 'viral Building Department 10050 N.E.2nd Avenue R Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: zz Property Address: Roofing Permit Number: Dear Building Official: I d I 'teff -,>-V a certify that I am not required to retrofit the roof to wall connections of my building because: ❑The o just valuation for the structure for s � purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. athe building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions of 1994 edition of the South Florida Building Code(1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn,d ses and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this Tai day of -2o f 3 Ana Elizabeth Raiszadeh COMMISSION#DD895323 Z EXPIRES: SEP.22,2013 Notary Public, Sate of Florida at Large au�o WWW.AARONN07ARY.com • When the just valuation of the structure for purpose of ad valorem on is equal to or re than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to Wail connection Hurricane Mitigation. Revised on 5121/2009