Loading...
MC-13-594 Inspection Worksheet Miami Shores Village J 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-188062 Permit Number: MC-3-13-594 Scheduled Inspection Date: April 24,2013 Permit Type: Mechanical- Residential Inspector: Perez,JanPierre Inspection Type: Final Owner: CASTANEDA, DAVID&KARA Work Classification: A/C Replacement Job Address:68 NW 97 Street Miami Shores, FL 33150- Phone Number (786)281-1825 Parcel Number 1131010330340 Project: <NONE> Contractor: CENTRAL AIR CONTROL INC Phone: 305-822-1551 Building Department Comments INSTALLATION OF DUCTLESS MINI SPLITS Infractio Passed Comments INSPECTOR COMMENTS False -Z4 J Inspector Comments Passed La Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. April 23,2013 For Inspections please call: (305)762-4949 Page 18 of 43 S P Miami Shores Village ISAR 2 6 7013 Building Department BY---k- om _---- 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795.2204 Fag:(305)756.8972 INSPECTION'S PHONE NUMBER:(305)762.4949 FBC 20 BUILDING Permit No. PERMIT APPLICATION Master Permit No. Permit Type: MECHANICAL JOB ADDRESS: 68 NW 97 ST City: Miami Shores County: Miami Dade Zip: 33150 Folio/Parcel#: 11-3101-033-0340 Is the Building Historically Designated:Yes NO X Flood Zone: N/A OWNER:Name(Fee Simple Titleholder):David and Kara Castaneda Phone#:305-775-0872 Address:68 NW 97 ST City: MIAMI SHORES State: FLORIDA Zip: 33150 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: CENTRAL AIR CONTROL INC Phone#: 3058221551 Address: 2651 W 79 ST City: HIALEAH State: FL Zip: 33016 Qualifier Name: RENE ALVAREZ Phone#: 3055580499 State Certification or Registration#: RA0022078 Certificate of Competency#: 000009831 Contact Phone#: 3058221551 Email Address: customerservice @centralaircontroi.com DESIGNER: Architect/Engineer: Phone#: I Value of Work for this Permit:$ b� Square/Linear Footage of Work: ❑ ® Type of Work: ❑Address Alteration ❑New (Repair/Replace ❑Demolition Description of Work: installation of 2 ductless mini splits �x�*�mxmx�x*����*��xm�mxxx�xx�xx�x�xxx�Feesx*xx+x>Km����xx�x��*�xxx�x�xx�x�w+xx�xxxx+�x��xx Submittal Fee$ Permit Fee$ ?` '� 1�")_—CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ P Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT."' Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first in do which occurs se n (7) days after the building permit is issued. In the absence of such posted notice, the inspection will of be pprov d9a rei, spection fee will be charged. y I 8I E f Signature Signature O e or gent Contractor The foregoing instru ent was acknoedged before me this The foregoing instrument was acknowledged before me this� day of A�" 20 11 ,by POWA 60 &,Al, day of Plk,-A ,20 L,by 6evi z d Al ywe Z who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: �•�^� Print d C ANN FE E - Print: P4/2+ 9642 _.; AMU My Commission Expires: ,m^, EXPIRES sine 23 2014 My Commission Expires: ; , e�; My COMMISSION C;®999642 ' ®� ®�° %aiaie EXPIRES Jane 23, /etee a F�OPI�C.R?O'ut}��01'L'VC3.COff1 e1eeo+ 2®14 4n7 398-0153 (407)398-0153(4- )3) ' �rySerfi:a.com APPROVED BY laTLs miner Zoning Structural Review Clerk Revised 3 112/2012)(Revised 07 110/07)(Revised 06/10/2009)(Revised 3115/09) ` 4 CENTR16 OP ID:AG A R° CERTIFICATE OF LIABILITY INSURANCE D 03/1 9/201 3 1 03/19/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED I REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WANED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Phone:305-364-7800 CONTACT NAME: BROWN&BROWN OF FLORIDA INC Fax:305-714-4401 PHONE FAX 14900 NW 79th Court SuiteN00 roc.Nor. Miami Lakes,FL 33016-5869 ADDRESS:AlL Ernie Sariol INSURER(S) AFFORDING COVERAGE NAIC# INSURER A:National Trust Insurance Co. 20141 INSURED Central Air Control Inc. INSURER B:FCCI Commercial Insurance Co 33472 2651 West 79th Street INSURER c:FCC[Insurance Company 10178 Hialeah,FL 33016 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE ADD SUB POLICY NUMBER POLICY EFF POLICY EXP GENERAL LIABILITY EACH OCCURRENCE $ 1,000,00 A X COMMERCIAL GENERAL LIABILITY GLOO103233 05/14/2012 05/1412013 PREMISES Ea occurrence $ 100,0 CLAIMS-MADE _ OCCUR MED EXP(Any one person) $ 5,00 X Contractual PERSONAL&ADV INJURY $ 1,000,00 GENERAL AGGREGATE $ 2,000,0 GEML AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,00 POLICY X PRO- Loc Emp Ben. $ 1,000,00 AUTOMOBILE LIABILITY Ea accidentgIN MIT $ 1,000,00 A X ANY AUTO CA00159953 05/14/2012 0511412013 BODILY INJURY(Per person) $ ALLOWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ X HIRED AUTOS X NON-OWNED PROPER DAMAGE AUTOS Per accident $ $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,0 B EXCESS LIAB CLAIMS-MADE UMB00041557 05/14/2012 05114MO13 AGGREGATE $ 2,000,00 DED I X I RETENTION$ 10000 $ WORKERS COMPENSATION WCSTATU OTH AND EMPLOYERS'LIABILITY YIN X TORY LIM ITS ER C 0 FIF GERM BRR FARTNER/E CUTIVE N/A under 001 WC12A62011 07/01/2012 07/01/2013 E.L.EACH ACCIDENT $ 500,00 (Mandatory in NH)n der E.L.DISEASE-EA EMPLOYEd$ 500,00 If describe DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMB I$ 500,00 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,H more space is required) • CERTIFICATE HOLDER CANCELLATION MIAMISH SHOULD)ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Village of Miami Shores THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Avenue AMORREDREPRESENTATIVE Miami Shores,FL 33138 W ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD C f; nj x � .. 35i'm s_ 5'RMe+ ,�'� ��, �' T�xti �"� - 5'Y �'� h �•y�, .s.�,�z �5,��'.r� .��rd° N ��.w t���,r'�� �.. Y T" x¢s 'S � t,'2� � �.�^ a .d' "'� � •`.� ��-�, r n; t.It`'���tyS>���i'..�3'�,� �°���, >�' ,y rrofi' k ^e'g t�. � Hg' "L. ':f:aR.'.`s 5. � �� �� � �.. �� � �$ Y�r15•3 �Sv�.M1 �A�� [���X4� �d w�e� '� �r a y ���� � � � ? � s � f� �-r.• is-'�s4" � >'k�� 'e �3'.s .�'N�'��s 4� ��. �tt � �� � 'J4�+ P F'. �,. P` � -fin � � .. � y.>,� �u f hyyn{ lA�h-'F��S .`• y X �� fi aFt Gi �I a. `¢•� k��x �r��'�" "'�+" r�'e,;� xr^•. ��. g... +��' a.., Y'+,� k�� 3 t -.;.. r'•, P��"�'a• dl K R. �" '� X"'A�'�''"�' ,`�" �'' ^, `s'ne� u .y� .�`$� .. �' ��«v ,t.,�yi,`�""a�`;v rta .s. '"� .s c rr. ','`a:� ���.��' �� z"'' ' `�'�,+.��i;Wr�4 ��� •r�,ft3�r��.t,���x Ado r"i �'>°`�C ���&` 'rf� *L� �1` } �as^Y} "�` '4 dm' '' T n ''- 1, " P' „a �'N- '+jam •��e etn' :..v �'k� »� "v�•F,„:a.��,'�f, -:�'+���'��..x. �x`'��- '"�ti<�i Po'"l"�.�n`�" "r.�4°.}.��d',�e,,9�' a -�sx..:,�vw:. .0 �.w�.-�,� °; �'.. -�,a �, �-.,� �i."` n� M 8�„�,`..".:r _ �: � _� � �4`���• �."ks:F..fiG `��. o-F.'Ft L � #°":av �� '. '9` �>`' uFS �R a � a,� �"+�" � ` ��,�,..��• �`� .�� Syr y�y ,� .�'�.: r� �f -;..+ '•1°p�. �-a'�' " �a�n4: 9,�.:� '�� �� .�i �s �%?��„ ��'��x-Y,� c"�;�+`. .,j�'�ir,'rt.,�,•`�j, ix.� a� ,Sa�^�S n' �" ,��'�K?,. •.�:x- >ex ,t'""'ee? r ref t -V ^�'��t� ' _,�t�c, , },� .,_4Ft, ,..`yCMay ,r�s:,s� v��"s "�P 7 -r�r• a a,.��; ��'" f,F.. 4. ��,�'),"� a _.,.h,�,��,,,k". .ham �z a y��. `F-s�'�� Mali� .. �.<;:.>'�� H wSr�.`. "�., .��+. ��� ,�� ° + x `'f' .,gym ' s s��"5�+ "�',`• ------ 1 1 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm.A-100, Ft. Lauderdale, FL 33301-1895—954-831-4000 VALID OCTOBER 1,2012 THROUGH SEPTEMBER 30,2013 DBA: Receipt#:HEATING/AIRCONDITION CONT R Business Name:CENTRAL AIR CONTROL INC Business Type:(AIRCONDITION CONTRACTOR) Owner Name:REM A ALVAREZ/QUAL Business Opened:lo/06/2000 Business Location:2651 W 79 ST State/County/CertfReg:CMC 311 MIAMI DADE COUNTY Exemption Code: Business Phone:305-822-1551 Rooms seats Employees Machines Professionals 20 For Vending Business Only Number of Machines: Vending Type: Tax Amount Transfer Fee I NSF Fee Penalty Prior Years Collection Cost Total Paid 54.00 0.00 0.00 0.00 0.00 0.00 54.00 + I THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non-regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location.This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: RENE A ALVAREZ/QUAL Receipt #30A-11-00002788 2651 W 79 STREET Paid 07/11/2012 54.00 HIALEAH, FL 33016 I 2012 . 2013 * � = : STATE OF FLORIDA DEPAR NT: OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD SEQ#L11080900328 a . L CENSE NBR 0'a/0-9 2011 00009.Od00 RA 0022078 A AT, TI©LNG CONTRACT-O " T m 3 1E AS REGISTERED fTside tleravisioas o£ Chapter 489 FS. Expi ation da;"t <A'I;TG 311 2013 ( it�Il ;' ' '° `$ xL LOCAL L16TSING R ;QQtFt + S PRIOR - °COX-- CTING, IN ANY AR,r, } ALVtLZ, ,RENE AIR CONTROL INC eqWT T SW 'ltlTRET 1I FL 33176 RIC�Cy,Sf~OTT: Kit"LA'�T"3Ow. O V TtN"43R SEC TA*Y DISPLAY AS REQUIRED BY LAIN STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 1940 NORTH MONROE STREET •�"aaows+�'``• TALLAHASSEE FL 32399-0783 ALVAREZ, RENE A CENTRAL AIR CONTROL INC 9241 SW 101 STREET MIAMI FL 33176 sra oaa 567457 Congratulationsl With this license you become one of the nearly one million OypAR ; OF tv.01 o AND Floridians licensed by the Department of Business and Professional Regulati on. PROrEIONAL REGULATION Our professionals and businesses range from architects to yacht brokers,from boxers to barbeque restaurants,and they keep Florida's economy strong. _RA0022078.. ;' 9.809 j].l 000000000 Every day we work to improve the way we do business in order to serve you better. For information about our services,please log onto www.myfloridalleense.com. REG AIR C© _. TIONIXG CONTRACTOR There you can find more information about our divisions and the regulations that ALVAREZr , A4 impact you,subscribe to department newsletters and learn more about the CENTRAL AIR .CONfiROL SNC Department's initiatives. (INDIVIDUAL` MST I ALL LOCAL LICENSING -R!$UIRE>!;�SNTS. PRIOR Our mission at the Department is: License Efficiently, Regulate Fairly.We TO CONTRACTING IN ice' AREA) constantly strive to serve you better so that you can serve your customers. HAS P�CGXSTMM =der the p=wLsions of ca.469 Thank you for doing business in Florida,and congratulations on your new licensel asraei aae.. Ap3 31,, :20,l3 L11080900328 DETACH HERE QUALIFYING TRADE(S) w�� 0003 A/C-UNLTD ''. Construction Trades Qual fy ing Board „< BUSINESS CERTIFICATE OF COMPETENCY 000009831 i j ; CENTRAL AIR CONTROL-INC Chad"Danger P.E ti OWN www.m4midade. dWdMbg D.B.A.. �RNE ALVAR EZ A Is certified under the provisions of Chapter 10 of Miami-Dade County MIAMI-DADE 196 SPEC MECHANICAL CONTRACTOR _ FlF�STOLASS UAS.PAID A©E PERMIT NO 2V 054065-9 THIS IS NOTA BILL—DO NOT P'AY BUSINESS NAM/LOCAUM RENEWAL CENTRAL AIR CONTROL INC CC REC5PTNo. 054065-9 265.1 W 79 ST 000009831 33016 HIALEAH owmm CENTRAL AIR CONTROL INC ' Sw T6 SPEC MECHANICAL CONTRACTOR WORKER/S arrAr 10 E BB T Fm6ev1 *r om 4mx.w _."WY tv om ff wamiiprp 00 NOT FORWARD pmx, !!C APAUm SY LAV.TF061S M"A CWpw naf o� CENTRAL AIR CONTROL INC MW RCA- RENE ALVAREZ PRES PVA� HIALEAN FL X3016 2651 W 79 ST I T„� 07/19/2012 60090000111 000045.001� 3iii �•iii!lf�flllii71i111177� ii sFiit�flf!!lil ��l�Sf �y-- SEE OTHER SME m EXISTMA LOAD POIR PANIM A "VIC a -PH µHR 2 7 zm TOT.Q.2/2 A x 120V . ......... ToTAL Oww WA %ro POR TOTAL LOAD 7 w vnt L 70NING DEPT BLDG DEPT rA SUBJECT TO COMPLIANCE WITH ALL FEDFf STATE AND COI,INTY RULES AND REGUL I NS A �j6er- Y.2 �f� �lz2�e3 ash ' °°)g e VAIL. of Hokk o� ` l �f 1�gdt Vtltt a 3 -25' C( T 3 5 -37 ratan, � - -I VA vs n°taaWu VaIN/�� r j �► E Size 9 12 15 17 22 i Outdoor Model RAS-09LKV-UL RAS-12LKV-UL RAS-15LKV-UL RAS-17LKV-UL RAS-22LKV-UL 13 Indoor Model RAS-09LAV-UL RAS-12LAV-UL RAS-15LAV-UL RAS-17LAV-UL RAS 22LAV-UL Cooling Rated Capacity Btulh 9000 12000 15000 16200 21400 Cooling Range Capacity 3750-10580 2750-13950 2750-17060 3750-20450 4100-22500 EER Btu/h.W 13.00 12.60 13.00 12.60 8.30 € SEER Btu/h.W 20 23 20 19 15.5 g Heating Rated Capacity Btulh 10800 14200 18DW 20200 23200 A Heating Range Capacity 3070-16350 3070-19000__ 3070-23500 2750-21500 3450-24350 COP Btu/h.W 13.50 13.00 12.80 12.40 10.50 HSPF 10 9.7 9 9 9 MWireless(°C,°F,Convertible) Yes Yes Yes Yes Yes IR or RF IR IR IR IR IR Cooling ma Outdoor Min-Max DB T 14-115 14-115 14-115 14-115 14-115 Indoor Min-Max DB T 70-M 70-90 70-90 70-•90 70-•90 Indoor Min-Max W B T 59-75.2 59•-75.2 59-75.2 59-75.2 59-75.2 Heating g Outdoor DB Min-Max T 6-75 5-75 5-75 5-75 5-75 Outdoor WB Win-Max T 4.1-64.4 4.1`64.4 4.1-64.4 4.1"64.4 4.1"64.4 Indoor DB Min-Max T Less than 82 Less than 82 Less than 82 Less than 82 Less than 82 Min.Piping Length It(m) 6.6(2) 6.6(2) 6.6(2) 6.6(2) 6.6(2) Standard Piping Length It(m) 16(5) 16(5) 25(7.5) 25(7.5) 25(7.5) Max Piping Length with no � additional refrigerant charge ft(m) 50(15) 50(15) 50(15) 50(15) 50(15) a Max Piping Length ft(m 66 20 66 20 66 20 66 20 66 20 Additional refrigerant charge (between 50-66 fL115-20 m 0.22 ozRt(ZOg/m) 0.22 ozfft(20g1m) 0.22 ozHt(20g/m) 0.22 ozfft(20g1m) 0.22 ozlft(20glm) Gas Pipe(size/connection type) in 316 318 112 1/2 12 Liquid Pipe(size/connection type) in 1/4 114 1/4 1/4 114 Voltage V-Ph-Hz 208/230-1-00 208230-1-60 208230-1-60 208230-1-60 206/230-1.60 Indoor Unit Connected from Outdoor(Yes/No) Yes Yes Yes Yes Yes Number of Conductors Between 4 4 / 4 4 Indoor and Outdoor Units Type of Wire(Shielded-yes or no) No No No No No Cooling Power Consumption W 690(250-820) 950(150-1250) 1150(160-1720) 1285(190-2010) 2570(210-2720) El Heating Power Consumption W 800(170-1400) 1090(160-1580) 1400 160-1990) 1630(150-1910) 2200 190-2440) Cooling Running Current A 3.33(1.36-3.75) 4.35(0.93-5.66) 520(0.94-7.60) 5.80(1.12-8.90) 11.5(1.25-12.10) Heating Running Current A 3.74(0.92-6.21) 4.99(0.99-7.00) 6.30 0.96-8.80) 7.30(0.90-8.60) 9.9(1.14-10.80) MCA A 10 13 3 13 15 MOPA A 15 20 20 25 Dimensions Height in(mm) 21-11/16(550) 21-11/16(550) 21-11116(550) 21-11/16(550) 21-11/16(550) Width in(mm) 30-11/16(780) 30-11/16(780) 30-11116(780) 30-11116(780) 30-11/16(780) o Length in(mm) 11-7116(290) 11-7116(290) 11-7/16(290) 1 11-7116(290) 11-7/16(290) Weigh-Gross/Net Ibs(kg) 82 37)/75(34) 95(43)/88(40) 96(44)191(41) 98(44)/91(41) 100(45)/93(42) O Refrigerant charged Ibs(kg) 1.77(0.80) 2.43(1.10) 3.09(l.40) 3.09(l.40) 3.09(l.40) Variable Speed Outdoor Motor(Yes/No) Yes Yes Yes Yes Yes Appearance White White White White White Sound Pressure(dBa) dBa 47 50 51 52 53 L Type DA89X1C-23F22 DA111A1F-20F2 DA130A1F-27F1 DA130A1F-27F1 DA150A1F 20F1 E Motor DC-INVERTER DC-INVERTER DC-INVERTER DC-INVERTER DC-INVERTER Dimensions Width in(mm) 10.25/32(275) 1045132(275) 12-19/32(320) 12-19132(320) 12-19/32(320 Height in(mm) 31-1/8(790) 31-1/8(790) 41-5116(1050) 41.5116(1050) 41,5/16(1050) Length in(mm) 8-1/16 205) 8-1/16(205) 8-15/16(228) 8-15/16(228) 8-15116(228) Weight-Gross/Net Ibs(kg) 25(11)/20(9) 25(11)/20(9) 35(16)/29(13) 35(16)29(13) 35(16)29(13) $ Appearance White White White White White c Sound Pressure at Different Speeds (cooling operation) dBa 39/36/34/3027 45142140/35/30 44141136/35132 47/44/41/38/35 47/44/41/38!35 Sound Pressure at Different Speeds dBa 40/37/35/3229 46/43/41136/32 44/41/39/35/32 47/44142/38135 47144/42/38135 (heating operation) Air flow (cooling operation) CFM 3031 274/244211/177 4061 355/304/282/219 5821 504/445/3961348 638/571/505!4471388 636!571/5051447!388 Airflow (heating operation) CFM 335/304/272242211 4381396/353/300247 5831 544/505/440/374 646/609/572/498/420 646160915721498/420 TOSHIBA CARRIER(THAILAND)CO.,LTD. 2/37 r Residential System Sizing Calculation Summary Project Title: 68 NW 97 ST AC REPLACEMENT(68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- 3/27/2013 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(7 ft.) Temp Range(L) Humidit data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 58 r. Winter design temperature(MJ8 99%) 50 F Summer design temperature(MJ8 99%) 90 F Winter set p oint 70 F Summer setpoint 75 F Winter temperature difference 20 F Summer temperature difference 15 F Total heating load calculation 8699 Btuh Total cooling load calculation 25595 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 395.4 34400 Sensible (SHR= 0.70) 94.7 19740 Heat Pump + Auxiiiary(0.01<W) 395.4 34400 Latent 178.0 8460 Total Electric Heat Pump) 110.2 28200 WINTER CALCULATIONS Winter Heating Load for 460 sqft) Load component Load Window total 128 sqft 2894 Btuh Wall total 776 sqft 1414 Btuh Door total 96 sqft 883 Btuh � Ceiling total 460 sqft 742 Btuh 'V Floor total See detail report 1463 Btuh a Infiltration 59 cfm 1303 Btuh Duct loss 0 Btuh Subtotal 8699 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS 8699 Btuh SUMMER CALCULATIONS Summer Cooling Load for 460 sqft) Load component Load Window total 128 sqft 9490 Btuh Wall total 776 sqft 1060 Btuh Door total 96 sqft 1325 Btuh Ceiling total 460 sqft 2745 Btuh Floor total 0 Btuh Infiltration 44 cfm 733 Btuh ss, Internal gain 5490 Btuh Duct gain 0 Btuh int Ga.n,21 , Sens.Ventilation 0 cfm 0 Btuh �/ Blower Load 0 Btuhr ; Total sensible gain 20843 Btuh Latent gain(ducts) 0 Btuh Latent gain(infiltration) 1752 Btuh Latent gain(ventilation) 0 Btuh ''" 5''''' Latent gain(internal/occupants/other) 3000 Btuh Total latent gain 4752 Btuh TOTAL HEAT GAIN 25595 Btuh EnergyGaugeO System SSiz�g control,Inc' 8th Edition PREPARED BYw®n !!ff DATE: EnergyGaugeO/USRFZB v3.0 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Project Title: 68 NW 97 ST AC REPLACEMENT (68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- Building Type: User 3/27/2013 Reference City: Miami, FL (Defaults) Winter Temperature Difference: 20.0 F (MJ8 99%) Component Loads>for Room#1:'GARACE , Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 1, Clear Metal 1.13 W 20.3 22.6 458 Btuh 6 1, Clear Metal 1.13 W 17.8 22.6 402 Btuh Window Total 38.0 s ft 859 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Conc Blk,Hollow - Ext (0.179) 3.0/0.0 104 3.57 371 Btuh 2 Conc Blk,Hollow - Ext (0.179) 3.0/0.0 162 3.57 578 Btuh 3 - Int (0.179) 11.0/0.0 200 0.00 0 Btuh 4 - Int (0.179) 11.0/0.0 180 0.00 0 Btuh Wall Total 646 s ft 950 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Exterior, n (0.460) 96 9.2 883 Btuh Door Total 96 s ft 88313tuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/D/Tile (0.081) 11.0/0.0 400 1.6 645 Btuh Ceiling Total 400 s ft 645Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 40.0 ft(perim.) 23.6 944 Btuh Floor Total 400 s ft 944 Btuh Room Envelope Subtotal: 4282 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.77 4000 0.67 39.8 875 Btuh Duct load No ducts assigned to this zone. (DLM of 0.000) 0 Btuh Room#1 Sensible Room Subtotal 5157 Btuh Component Loads for Room#2:OFFICE Window Panes/Type Frame U Orientation Area s ft X HTM= Load 2 1, Clear Metal 1.13 W 18.1 22.6 408 Btuh 3 1, Clear Metal 1.13 S 36.1 22.6 816 Btuh 4 1, Clear Metal 1.13 E 18.1 22.6 408 Btuh 5 1, Clear Metal 1.13 S 17.8 22.6 402 Btuh Window Total 90.0 s ft 2035 Btuh EnergyGauge®/USRFZB v3.0 Page 1 , Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 68 NW 97 ST AC REPLACEMENT (68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- Building Type: User 3/27/2013 Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 5 Conc Blk,Hollow - Ext (0.179) 3.0/0.0 32 3.57 114 Btuh 6 Conc Blk,Hollow - Ext (0.179) 3.0/0.0 66 3.57 236 Btuh 7 Conc Blk,Hollow - Ext (0.179) 3.0/0.0 32 3.57 114 Btuh Wall Total 130 s ft 464 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 2 Unvent Attic/D/Tile (0.081) 11.0/0.0 60 1.6 97 Btuh Ceiling Total 60 s ft 97Btuh Floors Type Ueff. R-Value Size X HTM= Load 2 Slab On Grade (1.180) 0.0 22.0 ft(perim.) 23.6 519 Btuh Floor Total 60 s ft 519 Btuh Room Envelope Subtotal: 3115 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.77 600 0.33 19.4 428 Btuh Duct load No ducts assigned to this zone. (DLM of 0.000) 0 Btuh Room#2 Sensible Room Subtotal 3542 Btuh SYST 1110 113S(BLOCK LOADS) Heating Loads For System(s):1 Block load 5157 Btuh Serving Rooms: 1 Heating Loads For System(s):2 Block load 3542 Btuh Serving Rooms: 2 EnergyGauge®/USRFZB 0.0 Page 2 i Manual J Winter Calculations Residential Load - Component Details (continued) Project Title: 68 NW 97 ST AC REPLACEMENT (68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- Building Type: User 3/27/2013 HOLE,HOUSE'TOTALS Subtotal Sensible Heat Loss 8699 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 8699 Btuh EQUIPMENT 1. Electric Heat Pump # 20200 Btuh 2. Electric Heat Pump # 14200 Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge®/USRFZB v3.0 Page 3 System Sizing Calculations - Summer Residential 1-1oad - R om by Room Component l etails Project Title: 68 NW 97 ST AC REPLACEMENT(68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- 3/27/2013 Reference City: Miami, FL Temperature Difference: 15.OF(MJ8 99%) Humidity difference: 58gr. Component :Loads for Room#11' GARAGE Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 1 Clear 0.74, 1.13 No No W 0.1ft 2.Oft 20.3 0.0 20.3 33 89 1804 Btuh 6 1 Clear 0.74, 1.13 No No W 0.1ft 2.Oft 17.8 0.0 17.8 33 89 1584 Btuh Window Total 38 (sqft) 3389 Btuh Walls Type LI-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow-Ext 0.18 3.0/0.0 104.0 2.7 279 Btuh 2 Concrete Blk,Hollow-Ext 0.18 3.0/0.0 162.0 2.7 434 Btuh 3 Int 0.18 11.0/0.0 200.0 0.0 0 Btuh 4 Int 0.18 11.0/0.0 180.0 0.0 0 Btuh Wall Total 646 (sqft) 712 Btuh Doors Type Area (sqft) HTM Load 1 Wood-Exterior 96.0 13.8 1325 Btuh Door Total 96 (sqft) 1325 Btuh Ceilings Type/Color/Surface LI-Value R-Value Area(sqft) HTM Load 1 Unvented Attic/DarkTile 0.081 11.0/0.0 400.0 5.97 2387 Btuh Ceiling Total 400 (sqft) 2387 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 400(ft-perimeter) 0.0 0 Btuh Floor Total 400.0 (sqft) 0 Btuh Zone Envelope Subtotal: 7813 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.58 4000 0.67 29.8 492 Btuh Internal Occupants Btuh/occupant Appliance Load gain 2 X 230 + 2400 2860 Btuh Sensible Envelope Load: 11165 Btuh Duct load No duct systernNo ducts assigned to this zone. (DGM of 0.000) 0 Btuh Sensible Zone Load 11165 Btuh Component Loads for Room#2: OFFICEz Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H Gross Shaded Unshaded Shaded Unshaded 2 1 Clear 0.74, 1.13 No No W 0.1ft 2.Oft 18.1 0.0 18.1 33 89 1609 Btuh 3 1 Clear 0.74, 1.13 No No S 0.1ft 2.Oft 36.1 0.0 36.1 33 35 1275 Btuh 4 1 Clear 0.74, 1.13 No No E 0.1ft 2.Oft 18.1 0.0 18.1 33 89 1609 Btuh 5 1 Clear 0.74, 1.13 No No S 0.1ft 2.Oft 17.8 0.0 17.8 33 35 627 Btuh Window Total 90 (sqft) 5121 Btuh- EnergyGauge@)/USRFZB v3.0 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL_AP 68 NW 97 ST AC REPLACEMENT(68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- 3/27/2013 Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 5 Concrete Blk,Hollow-Ext 0.18 3.0/0.0 31.9 2.7 86 Btuh 6 Concrete Blk,Hollow-Ext 0.18 3.0/0.0 66.1 2.7 177 Btuh 7 Concrete Blk,Hollow-Ext 0.18 3.0/0.0 31.9 2.7 86 Btuh Wall Total 130 (sqft) 348 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 2 Unvented Attic/DarkTile 0.081 11.010.0 60.0 5.97 358 Btuh Ceiling Total 60 (sqft) 358 Btuh Floors Type R-Value Size HTM Load 2 Slab On Grade 0.0 60(ft-perimeter) 0.0 0 Btuh Floor Total 60.0 (sqft) 0 Btuh Zone Envelope Subtotal: 5828 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.58 600 0.33 14.6 241 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 X 230 + 2400 2630 Btuh Sensible Envelope Load: 8698 Btuh Duct load No duct systemNo ducts assigned to this zone. (DGM of 0.000) 0 Btuh Sensible Zone Load 8698 Btuh The following window Excursion will be assigned t6 the system loads. Windows July excursion for System 1 980 Btuh July excursion for System 2 0 Btuh Excursion Subtotal: 980 Btuh Duct load 0 Btuh Sensible Excursion Load 980 Btuh i EnergyGauge®/USRFZB 0.0 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL_AP 68 NW 97 ST AC REPLACEMENT (68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- 3/27/2013 'SYSTEM GR©11P5(BLUCK LQA�S) Sensible Envelope Load 11165 Btuh Window Excursion 980 Btuh Cooling Loads Sensible Duct Load (duct gain multiplier of 0.000) 0 Btuh (Includes 0 Btuh due to window excursion) Sensible ventilation 0 Btuh For System(s): Zone Sensible gain 12145 Btuh 1 Latent infiltration/ventilation gain 1177 Btuh Serving Zones: Latent duct gain 0 Btuh 1 Latent occupant gain 400 Btuh Latent other gain 1200 Btuh Total block load 14922 Btuh Sensible Envelope Load 8698 Btuh Window Excursion 0 Btuh Cooling Loads Sensible Duct Load (duct gain multiplier of 0.000) 0 Btuh Sensible ventilation 0 Btuh For System(s): Zone Sensible gain 8698 Btuh 2 Latent infiltration/ventilation gain 575 Btuh Serving Zones: Latent duct gain 0 Btuh 2 Latent occupant gain 200 Btuh Latent other gain 1200 Btuh Total block load 10673 Btuh EnergyGauge®/USRFZB v3.0 Page 3 Manual J Summer Calculations Residential Load - Component Details (continued) Project Title: Climate:FL_MIAMI_INTL_AP 68 NW 97 ST AC REPLACEMENT(68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- 3/27/2013 m iRtHOLE HOUSE TO'I1L;5 Sensible Envelope Load All Zones 20843 Btuh Sensible Duct Load 0 Btuh Total Sensible Zone Loads 20843 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 20843 Btuh Totals for Cooling Latent infiltration gain (for 58 gr. humidity difference) 1752 Btuh Latent ventilation gain 0 Btuh Latent duct gain 0 Btuh Latent occupant gain (3.0 people @ 200 Btuh per person) 600 Btuh Latent other gain 2400 Btuh Latent total gain 4752 Btuh TOTAL GAIN 25595 Btuh EQUIPM IENT 1. Central Unit TOSHIBA-CARRIER#RAS17LKV.UL-RAS17LAV-UL 16200 Btuh 2. Central Unit TOSHIBA-CARRIER#RAS12LKV.UL-RAS12LAV-UL 12000 Btuh `Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device: none(No), Blinds(B), Draperies(D)or Roller Shades(R)) - For Blinds:Assume medium color, half closed For Draperies:Assume medium weave, half closed For Roller shades:Assume translucent, half closed (IS-Insect screen:none(N), Full(F)or Half('h)) (Ornt-compass orientation) Version 8 EnergyGauge®/USRFZB v3.0 Page 4 Residential Window Diversity MidSummer Project Title: 68 NW 97 ST AC REPLACEMENT (68 NW 97 ST) MIAMI SHORES MIAMI SHORES VILLAGE, FL 33150- 3/27/2013 Weather data far: Miami - Defaults` Summer design temperature 90 F Average window load for July 6902 Btuh Cooling setpoint 75 F Peak window load for July 9952 Btuh Summer temperature difference 15 F Excusion limit(130% of Ave.) 8972 Btuh Latitude 25.82 North Window excursion (July) 980 Btuh WINDOW Average and Peak Loads � 00�.01a 000.00 Limit fo,r excursion 7000.00 12 Hour Average 1 i �000.0t? �a 73 000. 0 700t�.00: 2000.00 1000.GG 0.00 0 a.m. 10 12 2 p.m. €p.m. 6 P.M. 9 p.m. a.m. Total July Window Load(Radiation and conduction) Warning:This application has glass areas that produce relatively large heat gains for part of the day. Variable air volume devices may be required to overcome spikes in solar gain for one or more rooms.A zoned system may be required or some rooms may require zone control. ��yy e EnergyGauge®System OSi�j�0QiUa'residences only PREPARED Bl�� !o F� DATE: "� 2 EnergyGauge®/USRFZB v3.0 4 �:... .. Toshiba-Carrier inverter technology L „ Toshiba-Carrier DC hybrid inverter technology controls the capacity supplied by the air conditioner. -° By modifying the supply current frequency or intensity,it ensures "R 23 _ smooth linear variation of the rotation speed and capacity of the compressor-the heart of the air conditioner. This allows the cooling and heating capacities to be matched to ~ " x the actual operating conditions required. , k When the room temperature is different from the set point,the air conditioner operates at maximum capacity,ensuring that a comfortable temperature will be reached quickly. Once the desired temperature is reached,the inverter precisely adjusts the capacity to maintain a temperature close to the set point. Technical specifications System. Outdoor Model RAS-09LAV-UL RAS-12LAV-UL RAS-15LAV-UL RAS-17LAV-UL RAS-22LAV-UL Indoor Model RAS-09LKV-UL RAS-12LKV-UL RAS-15LKV-UL RAS-17LKV-UL RAS-22LKV-UL Cooling Rated Capacity BTUH 9,000 12,000 15,000 16,200 21,400 SEER 20 23 20 19 15.5 Heating Rated Capacity BTUH 10,800 14,200 18,000 20,200 23,200 c HSPF 10.0 9.7 9.0 9.0 9.0 y'o Wireless('C,'F,Convertible) Standard-Convertible L Wired(°C,°F,Convertible) 3 Not Available Cooling utdoor Min-Max DB'F o 9 14-115 14-115 14-115 14-115 14-115 Heating OutdoorWBMin-Max'F 5-7S 5-75 5-75 5-75 S-75 0 Cooling Indoor D6 Min-Max°F 70-90 70-90 70-90 70-90 70-90 A Heating Indoor D8 Min-Max°F 32-82 32-82 32-82 32-82 32-82 v Total Piping Length ft. 66 66 66 66 66 s Piping Lift ft. 33 33 33 33 33 Voltage 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 a Power Supply Indoor connected from outdoor unit °- Outdoor Unit Outdoor-MCA 10 13 13 13 IS a n Outdoor-Fuse Rating(MOCP) 15 20 20 20 25 r Dimensions(w x h x d)In 30.7 x 21.7 x 11.4 30.7 x 21.7 x 1 1A 30.7 x 21.7 x 11.4 30.7 x 21.7 x 11.4 30.7 x 21.7 x 11.4 0 Net Weight(lbs.) 75 88 91 91 93 s Sound Pressure dBa(CIg/Htg) 47/47 50/50 51/S 1 52/52 53/S3 Indoor Unit _..... L Dimensions(w x h x d)In 31.1 x10.8x8.0 3 1.1 x 10.8 x 8.0 41.3 x 12.5 x 8.9 41.3 x 12.5 x 8.9 41.3x12.5x8.9 L Net Weight(lbs.) 20 20 29 29 Number of Fan Speeds 5 5 5 5 59 Sound Pressure(highest to lowest)Cig 39/36134/30/27 45/42/40/35/30 44/41/38/35/32 47/44/41/38/35 47/44/41/38/35 Sound Pressure(highest to lowest)Htg 40/37/35/32/29 46/43/41/36/32 44/41/39/35/32 47/44/42/38/35 47/44/42/38/35 M c m E a L H I O O 2 L d \�ytFkrp� 9 R-410A G T�ISTifl us www.carrier.com 1800-CARRIER