Loading...
MC-13-491 Inspection Worksheet Miami Shores Village 10050 N.E.2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-187242 Permit Number: MC-3-13-491 Scheduled Inspection Date: July 17,2013 Permit Type: Mechanical - Residential Inspector: Perez,JanPierre Inspection Type: Final Owner: SMITH, PATRICE AND SCOTT Work Classification: Addition/Alteration Job Address:358 NE 101 Street Miami Shores, FL 33138- . Phone Number Parcel Number 1132060135280 Project: <NONE> Contractor: AIR KING MECHANICAL CONTRACTOR, INC Phone:305-823-5888 Building Department Comments MECHANICAL WORK FOR INTERIOR REMODEL Infractio Passed Comments INSPECTOR COMMENTS False 17 Inspector Comments Passed Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. July 16,2013 For Inspections please call: (305)762-4949 Page 6 of 38 Miami Shores Village _ y 236 Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel: (305)795.2204 Fax:(305)756.8972 INSPECTION'S PHONE NUMBER:(305)762.4949 BUILDING Permit No. +9 PERMIT APPLICATION Master Permit No.-F-4 l �_ FBC 20 J Permit Type:MECHANICAL OWNER:Name(Fee Simple Titleholder): C--6>�1 S� I T'H Phone#: Address: S City: /74y2 E'S State:- �- Zip: 3 3 3 Tenant/Lessee Name. Email: JOB ADDRESS: r S iU Lf ,D S City: Miami Shores County: Miami Dade Zip: 33 L3•'8 Folio/Parcel#: Is the Building Historically Designated:Yes NO Flood Zone: CONTRACTOR:Company Name: S Kl t'ChQw i roA C-4*t t M hone#: Address:*335-1 Sun) I?-) Arq City: -1-k� t Cl m<7 State: J c9 G zip: 3d2� Qualifier Name: Anota AAE 9l! Phone#: State Certification or Registration k CQ C-QS'19 3'_ Certificate of Competency#: Contact Ph0ne#.b05';?_a35'= -N` 51i1Qail Address: DESIGNER:Architect/Engineer: 'W-40 Phone#: Value of Work for this Permit:$ L� SquarelLinear Footage of Work: Type of Work: OAddress OAher lion ONew ORepair/Replace ❑Demolition Description of Work: t Vct-.. cc�u �S �a r MCA-C- Submittal Fee$ Permit Fee$ � ��_ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ I 31 1�? <W Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COWKENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be-delivered to the.person whose property is subject to attachment Also, a certifted copy of the recorded notice of commencement must be posted at the job site for the fnrst inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be roved and a reinspe n fee will be charged Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day o ,2t)3,bSMF 0>-V4 11�'l day of A041(l .2013 by 6 o is perso y known to me or who has produced is personally wn to me or who has produced As identification and who did take an oath. as identification ath. NOTARY PUBLIC: NOTARY P ,. L ��� ' �� MY COPd�1tS$IOW�EE10 EXPIRES:JUL 05,2x16 /�/-- �° Bonded through 1st State I� Sign: Print: Print: cl► a C v1'�o�,^ My Commission Expires: My Commission Expires: * APPROVED BY Plans Examiner Zoning 13 Structural Review Clerk (revised 07/10ro7)(Revised o611012009)(Revised 3/15/09) Miami Shores Village Building Department ton 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel.(305) 795 2204 (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA Fax: PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications.Each unit change-out must be on Its own data sheet.Multiple units on single sheets are not acceptable. Job Address(where the work is being done): City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI(AHRI)DATA SHEET REQUIRED Change Disconnecting means:YES ❑ NO❑ ARHI Sheet Attached:YES❑ NO❑ Contract Attached:YES❑ UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER AHU or PKG.UNIT MODEL# COND.UNIT MODEL# KW HEAT NOM TONS AHU CU PKG 1 M.C.A AHU CU PKG AHU CU PKG 2 M.O.P AHU CU PKG AHU CU PKG 3 VOLTS AHU CU PKG PKG UNIT / I PKG UNIT I I EER/SEER YES NO REPLACING DUCTS YES NO YES NO REPLACING THERMOSTAT YES NO YES NO NEW 4 000NCRETE SLAB I YES NO YES NO NEW ROOF STAND I YES NO YES NO NEW RETURN PLENUM BOX I YES NO 1. Minimum Circuit Ampacity(Wire Size): 2. Maximum Overcurrent Protection(Fuse/Breaker Size): 3. Voltage of Circuit(2081240/480): 4. Size Disconnecting Means: Contractor's Company Name: Phone: State Certificate or Registration N. Certificate of Competency N. Signature Date: tQuaMees signature only) c • � Air System Sizing Summary for AHU- Existing Project Name:Gillespie Smith Residence 01/30/2013 Prepared by:Ernesto Santana P.E. 10:59PM Air System Information Air System Name...._......._.......---------._--_._AHU-Existing Number of zones---------..........._..............____.___..................... 1 Equipment Class---------------------------------------------------SPLT AHU Floor Area........................-.....-.............................------------1758.9 ft' Air System Type......................__............................._...SZCAV Location_......................__..........................Fort Myers,Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM............................Sum of space airflow rates Calculation Months.........._.....-._------_-------_--- _-_Jan to Dec Space CFM._......................Individual peak space loads Sizing Data.................._.........__.-.----._-.----.-.--.----._-__.Calculated Central Cooling Coil Sizing Data Total coil load_-----------------_--__...................................._......3.7 Tons Load occurs at--------------_.................... Oct 1700-- Total coil load_.......................................------------------_._.......43.9 MBH OA DB/WB..........................................................89.5174.8 OF Sensible coil load................................................................42.9 MBH Entering DB/WB...................................................75.7/62.3 OF Coil CFM at Oct 1700................_...................................2022 CFM Leaving DB/WB.._._._-_-----_..._........................._.....56.0154.8 OF Maxblock CFM__..............._................................_......_...2022 CFM Coil ADP.._...---------------------_----.-._--_----------_..._.....................53.8 OF Sum of peak zone CFM.........................................__....2022 CFM Bypass Factor................_______.......... ,.._____.----------0.100 Sensible heat ratio------------------_____..................._......._0.877 Resulting RH-----------------_-.__-................. 46 % - ft2fTon.........................................._......................................481.2 Design supply temp........._._---------•-----._..---_-- -------------55.0 OF BTU/(hr-ft-).........._........................................................._.._24.9 Zone T-stet Check......_____......................___—----------1 of 1 OK j w-: Water flow @ 10.0 OF rise.................................................QUA Max zone temperature deviation...................._----------------0.0 OF Central Heating Coll Sizing Data Max coil load__......................._____.___._.............-.._-. _ 14.8 MBH Load occurs at--------------_...................................-_Des Htg Coil CFM at Des Htg........................................._...___-_2022 CFM BTU/(hr-ft2).__________________.-.._..............___ . _..---------------.____8.5 Max coil CFM.........................................................._...__..2022 CFM Ent.DB/Lvg DB------------_......................._..............69.7176.6 OF Water flow @ 20.0 OF drop..............................................N/A Supply Fan Sizing Data Actual max CFM........................_................................_....2022 CFM Fan motor BHP--------_____-----_-----------------_.•...._.._-•-•__---1.86 BHP Standard CFM.................-.............---------------_----------------2021 CFM Fan motor kW......................._---....................._-------------------1.38 kW Actual max CFM/ft2.............................................-.- _....1.15 CFM/ft2 Fan static-......................_..._................................-...-............3.50 in wg Outdoor Ventilation Air Data Design airflow CFM............................................----_-_-__._0 CFM CFM/person....................___-.................-__-.-._-------------0.00 CFM/person CFM/ft'....................................._.............. ---------- - - 0.00 CFIM2 e v� Hourly Analysis Program v.4.3 Page 1 of 1 Project Name:Gillespie Smith Residence Zone Sizing Summary for AHU- Existing 01/30/2013 Prepared by:Ernesto Santana P.E. 10:59PM Air System Information Air System Name.........._-_............................AHU-Existing Number of zones......._..-_..........................__--_---._--------------_1 Equipment Class---------------------------------..........SPILT AHU Floor Area---------------_---_......._-----------------------------------------1759.9 it Air System Type..........................-------------------------------SZCAV Location......_............................................Fort Myers,Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM----.-.---_-----_---------Sum of space airflow rates Calculation Months......---_..........................-------Jan to Dec Space CFM ...................Individual peak space loads Sizing Data-_--_-------._._..............._- _-_-__. Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow "Peak Load Area Zone Zone Name (MBH) (CFM) (CFM) Load (MBH) (fe) " CFMtW Zone 1 39.0 1962 1962 Oct 1700 20.3 1759.9 1.11 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name/ Sensible of Flow Load Area Space Space Name Mult. (MBH) Load (CFM) (MBH) (W)___ CFMW Zone f Bath 2 1 0.7 JUI 1800 34 0.4 37.0 0.93 Bed RM 2 1 5.7 Oct 1700 266 3.2 182.3 1.46 Bed RM 3 1 5.0 Jun 1800 230 3.0 165.0 1.40 Den 1 3.3 Jun 1800 152 1.6 117.1 1.30 Dining RM 1 1.4 Ju12100 63 0.1 133.2 0.48 Family RM 1 10.6 Oct 1700 489 5.7 369.0 1.33 Hall 1 0.6 Ju12100 29 0.2 84.5 0.34 Kitchen 11 2.8 Ju12100 128 0.1 112A 1.14 Living RM 1 4.2 Jun 1800 195 2.2 255.0 0.76 Master Bath 1 0.9 Ju12100 41 0.5 59.0 0.69 Master Bedroom 1 6.4 Oct 1700 297 3.0 193.0 1.54 Powder RM 1 0.41 Ju121001 181 0.0 20.4 0.88 WIC 1 0.41 Ju121001 191 0.0 32.OL 0.58 r Hourly Analysis Program v.4.3 Page 1 of 1 I a Air System Design Load Summary for AHU- Existing Project Name:Gillespie Smith Residence 01/30/2013 Prepared by:Ernesto Santana P.E. 10:59PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Oct 1700 HEATING DATA AT DES HTG COOLING OA D13 T WS 89.5 OF/74.9 OF HEATING OA DB/WB 42.0 6F/35.3 61F Sensible Latent Senstble Latent ZONE LOADS Details (BTU/hr) (BTt)/hr) Details (BTU/hr) (iTUmr); Window&Skylight Solar Loads 307 ft' 12038 - 307 ft' - - Wall Transmission 1278 ft' 3434 - 1278 ft' 4870 - Roof Transmission 1760 ft' 1175 - 1760 ft' 1849 - Window Transmission 307 ft' 4357 - 307 ft' 10315 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 23 ft' 149 - 23 ft' 353 - Floor Transmission 1760 ft' 0 - 1760 ft' 2811 - Partitions 161 ft' 87 - 161 ft' 36 - Ceiling 95 IF 26 - 95 ft' 25 - Overhead Lighting 3167 W 8135 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 2660 W 8138 - 0 0 - People 4 920 480 0 0 0 Infiltration - 0 0 0 0 Miscellaneous - 492 527 - 0 0 Safety Factor 0%/0% 0 0 0% 0 0 >>Total Zone Loads 38951 1007 20258 0 Zone Conditioning - 36990 1007 - 19045 b Plenum Wall Load 0% 0 - 01 0 - Plenum Roof Load 0% 0 - 0 0 Plenum Lighting Load 0% 0 - 0 0 Return Fan Load 2022 CFM 0 - 2022 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 2022 CFM 4723 2022 CFM -4723 - Space Fan Coil Fans - 0 - 0 - Duct Heat Gain/Loss 3% 1169 - 3% 608 - a>,Total System Loads - 42881 1007 14930 0 Central Cooling Coil - 42881 1008 - 0 0 Central Heating Coil - 0 - 14930 - Total Conditioning 428811 1008 - 1 301 0 Key: Positive values are clg loads Positive values are htg loads Negative values are htg loads Negative values are cig loads Hourly Analysis Program v.4.3 Page 1 of 1 ' ^ �= Air System Sizing Summary for AHU- Existing Project Name:Gillespie Smith Residence 01/30/20)]13 Prepared by:Ernesto Santana P.E. 10:59PM Air System Information Air System Name AHU-Existing Number of zones v Equipment Class—_— ..._............-.... '_.—mpL[AHu Floor Area ................__ -------_..................... .... ....«r5mo f2 Air System Type.................................---- ............SZCAy Location........................................—_'Fort Myers,Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CRN-..................—_'Sum wf space airflow rates Calculation Months........................... ....................Jan mwDoc Space CFM----------------------- Individual peak space loads Sizing Data..............._.—.................... ................Calculated Central Cooling Coll Sizing Data Total coil load................_... ............. -_—_'—_----3.7 Tons Load occurs ot...........................____ .................. Oct1mu0 Total coil load_................ ............................. ..............—.0.9 MoM Oune/mB................................... .........................o9.5/74.e ^F Sensible coil lood____........................ ........................42.o MoM Entering B/VVB 76.7162.3 ^F Coll CRNuu Oct 17uo___ .......... -----'_'_-202o CRN Leaving Do/vvs—' .....................__.................56.0/54.8 ^F Max block CRN___- -----........_.-----__-2072 CFW Coll ADP................__................—__—'—''__-_53.8 ^F Sum of peak zone[FM.................... ----------------------a02o CFM 0-100 Sensible heat ratio..... ..... ........................................... #.977 Resulting n*...... ............... ......... ..............................__4e % ft2non ... '... .................................... ...__—__.........4m1.2 Design 55.0 ^F --' --- --'_---_ ...................24.y Zone T-umu Check'__''--_--_--_--------- ___vwyI OK vvote,nmw@ 1V.U^F rise...................................... _—WA Max zone temperature deviation__'--'_--_..........m.0 ^F Central Heating Coll Sizing Data Max coil load...........---'_...............-...................... ....14.m MoV Load occurs omo Htg Coll CFMuu Des mg___—_--'-____'_--'u#2x CFM 8.5 Max coil CRN...............-- ................. ...... ---------------—om2o CFIV1 Ent.oa/Lvg D13 ^F Water flow @oou^p drop_-------_ -------------------—WA Supply Fan Sizing Data Actual max CFM-----------_ ................ _'- -------------—a#o2 CFM Fan motor BHP....... _ -------- ......... — -----------__'Y.86 BHP StandardCFM------------- ---- .....................--_-----------------o#u1 CFM Fan motor kW ........__................... ------------------ .......... 1.38 mm Actual max CpMoft2............................................................1'1m CFM/w Fan static----------- _..... ................. .........................— ........m.6w |nwg Outdoor Ventilation Air Data Design airflow CpM-----_----------------------__..........-...... 0 CRN CFWpersm ______________m00 oFWpemon CFM/ft2............................................................ .....................n.0# CFmW Hourly Analysis Program v.4.3 Pag 1 of I _ � � � Zone Sizing Summary for AHU- Existing Project Name:Gillespie Smith Residence 01/30/2013 Prepared :Ernesto Santana P.E. 10:59PM Air System Information Air System Name- .....................................AHU-Existing Number of zones............................_.-...................................... 1 Equipment Class---------------------------------------- - ..SPLT AHU Floor Area--........................................................-..............1759.9 ft' Air System Type............................................----.......SZCAV Location.----..............................................Fort Myers,Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM------------------------Sum of space airflow rates Calculation Months.....................-...-...-.............Jan to Dec Space CFM.........................Individual peak space loads Sizing Data...._.....-..............-.._.._--..--._---------------Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH) (CFM) (CFAA) Load (MBH) (ft), CFMW Zone 1 39.0 1962 1962 Oct 1700 20.3 1759.9 1.11 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name/ Sensible of Flow Load. Area Space Space Name Mult (MBH) Load (CFM) (MBH) (ft') CFM/fe Zone 1 Bath 2 1 0.7 JUI 1800 34 0.4 37.0 0.93 Bed RM 2 1 5.7 Oct 1700 266 3.2 182.3 1.46 Bed RM 3 1 5.0 Jun 1800 230 3.0 165.0 1.40 Den 1 3.3 Jun 1800 152 1.6 117.1 1.30 Dining RM 1 1.4 Ju12100 63 0.1 133.2 0.48 Family RM 1 10.6 Oct 1700 489 5.7 369.0 1.33 Hall 1 0.6 Ju12100 29 0.2 84.5 0.34 Kitchen 1 2.8 Ju12100 128 0.1 112.4 1.14 Living RM 1 4.2 Jun 1800 195 22 255.0 0.76 Master Bath 1 0.9 Ju12100 41 0.5 59.0 0.69 Master Bedroom 1 6.4 Oct 1700 297 3.0 193.0 1.54 Powder RM 1 0.4 Ju121001 181 0.0 20.4 0.88 WIC 1 0.4 Ju12100 19 0.0 32.0 0.58 Hourly Analysis Program v.4.3 Page 1 of 1 i Air System Design Load Summary for AHU- Existing Project Name:Gillespie Smith Residence 01/3012013 Prepared by:Ernesto Santana P.E. 10:59PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Oct 1700 HEATING DATA AT DES HTG COOLING OA DB/WB 89.5 OF 174.9 OF HEATING OA DB/WB 42A°F/35.3°F Sensible Latent Sensible Latent ZONE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window&Skylight Solar Loads 307 ft2 12038 - 307 ft2 - - Wall Transmission 1278 if 3434 1278 ft2 4870 - Roof Transmission 1760 ft2 1175 1760 f12 1849 - Window Transmission 307 f12 4357 - 307 f12 10315 - Skylight Transmission 0 ft2 0 - 0 fe 0 - Door Loads 23 f12 149 - 23 ft2 353 - Floor Transmission 1760 fI2 0 - 1760 ft2 2811 - Partitions 161 ft2 87 - 161 f12 36 - Geiling 95 ft2 26 - 95 f12 25 - Overhead Lighting 3167 W 8135 - 0 0 - Task Lighting ow 0 - 0 0 - Electric Equipment 2660 W 8138 0 0 - People 4 920 480 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 492 527 - 0 0 Safety Factor 0%/0% 0 0 0% 0 0 Total Zone Loads - 38951 1007 20258 0 Zone Conditioning - 36990 1007 - 19045 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 2022 CFM 0 - 2022 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 2022 CFM 4723 - 2022 CFM -4723 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain/Loss 3% 1169 - 3% 608 - a>Total System Loads 42881 1007 14930 0 Central Cooling Coil - 428811 1008 - 0 0 Central Heating Coil - 0 -1 14930 - Total Conditioning 428811 1008 14930 O Key: Positive values are clg loads Positive values are htg loads Negative values are htg loads I Negative values are cig loads Hourly Analysis Program v.4.3 Page 1 of 1