RF-12-1900r
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 187056 Permit Number: RF -10 -12 -1900
Scheduled Inspection Date: April 19, 2013
Inspector: Bruhn, Norman
Owner: CARNEY, MIKE ANDROBIN
Job Address: 235 GRAND CONCOURSE
Miami Shores, FL 33138-
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number (305)758 -9980
Parcel Number 1132060133620
Phone: (305)953 -3333
Building Department Comments
RE ROOF TO A NEW TILE ROOF
permit on hold until contractor has a meeting with bo
Infractio Passed Comments
INSPECTOR COMMENTS
False
Passed
7-
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
CREATED AS REINSPECTION FOR INSP - 179784. replace broken
sidewalk, 2 flags
April 18, 2013
For Inspections please call: (305)762 -4949
Page 3 of 11
Quality Roofing Contractor, Inc.
13800 N.W. 1st Avenue
Miami, Fl 33168
Tel: (305) 953 -3333
Fax: (305) 953 -3833
April 16, 2013
Miami Shores Village
Building Department
Ref: Permit # RF -10 -12 -1900
235 Grand Concourse
Miami Shores, Florida 33138
This letter is to inform you that the total cost of the roof was $24,000.00
15% of the $24,000,00 is $3,600.00
The cost to do the straps on the roof would cost about $7,500.00 with engineer, materials and labor.
Sincerely Yours,
Carlos Arocho
President
L�
QUALITY ROOFING CONTRACTOR, INC.
13800 N.W. 1st Avenue
MIAMI, FLORIDA 33168
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
B
PERMIT APPLICATION
FBC 20
Permit Type: BUILDING OOFIN�'T.
OCT o •
3 ,veo°oao�o
Permit No. 12'"1 00
Master Permit No.
Owner's Name (Fee Simple Titleholder) Robin Carney Phone # (3 0 5) 7 9 8 —2 5 9 6
Owner's Address 235 Grand Concourse
City Miami Shores S Florida Zip 33138
Tenant/Lessee Name Phone #
Email
Job Address (where the work is being done) 235 Grand Concourse
City Miami Shores Village County
FOLIO /PARCEL# 11- 3206 - 013 -3620
Is Building Historically Designated YES
Miami -Dade
Zip 331 38
NO X Flood Zone
Contractor's'CompanyNameQuality Roofing Contractor,
Contractor's Address 13800 N.W. '1 st Avenue
City Miami State
Qualifier Name Carlos Arocho
State Certificate or Registration No. RC 0 0 5 8 6 2 7
Contact Phone ( 305) 953 -3333
I done #
(305) .953 -3333
Florida Zip 33168
Phone# (786) 367 -2029
Certificate of Competency No. 0 0 0 01 78 8 9
E-mail qualityroofingiiil @yahnn _ com
Architect/Engineer's Name (if applicable) Phone #
Value of Work For this Permit $ 2 4 , 000 . 0 0 Square / Linear Footage Of Work: 3 5 0 0 s q f t .
Type of Work: DAddition []Alteration DNew ® Repair/Replace ❑ Demolition
Describe work: Reroof to a new tile roof . e0/0,411,L T.:1 4, 11
Submittal Fee $ Permit Fee $
Notary $
Scanning $ Radon $
Double Fee $ Violation date:
Structural Review. $
CCF $ CO /CC $
Training/Education Fee $
Technology Fee $
DPBR $ Bond $
Total Fee Now Due $
See Reverse side -+
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMIVIENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be appro1ed and a reinspection fee will be charged.
6
Signature (��-``r
Owner or Agent
The foregoing instrument was acknnowl • : ed before me this . S
day of , 20)) , by 12.0 i e� ?n ,)
who is personally own to me or who has produced
As identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
My Commission Expires:
APPROVED BY
NOTARY PUBLIC-ST OF FLORIDA
Marylou Hernandez
Commission #DD930046
Expires: OCT. 10, 2013
BONDED THRC ATLANTIC BO\-DLNG CO., INC.
Signature
Contractor
The foregoing instrument was acknowledged before me this ,25
day of S.L.14 ` . , 20)41- , by Tar kpro C,%-0 ,
who is personal�lyJ sown to me or who has produced
as identification and why did take an oath.
NOTARY PUBLIC:
Sign:
Print:
My Commission Expires. 0 "1",, Marylou Hernandez
Commission #DD930046
,.••° Expires: OCT. 10, 2013
tokab nau ATLANTIC BONDING CO., INC
Plans Examiner Zoning
Engineer Clerk checked
(Revised 07 /10 /07)(Revised 06/10/2009)
A RECORDED
NOTICE OF CO ENCEMENT
MUST BE POSTED ON THE JOB SITE ATTUNE OF FIRST INSPECTION
HI
•
PERMIT NO. TAX FOLIO NO. 11-3206-013-3620
STATE OF FLORIDA, C
1 HEREBY CERTfFY- 4ai this
origigal tied in This sift
STATE OF FLORIDA:
COUNTY OF MIAMI -DADE:
111111111111111111111111111 111111111011111111
C N 2012R0759493
OR Bi: 28326 F'9 2855; (:1P9))
RECORDED 10124/2012 09:2708
HARVEY RUVINP CLERK OF COURT
+ OUi' TYe FL
the
mot
THE UNDERSIGNED hereby gives notice that improvements will be mad (.7°':` '`;" Official C 20
property, and in accordance with Chapter 713, Florida Statutes, the followh tt tiCLiRK, F_ Circ
is provided in this Notice of Commencement. By
1. Legal description of property and street/address: 235 Grand Concourse
Miami Shores, Florida 33138
2. Description of improvement. Reroof to a new Tile roof .
3. Owner(s) name and address' Robin Carnev
235 Grand Concourse
Miami Shores, Fl 33138
Interest in property. Owner
Name and address of fee simple titleholder. N/A
4. Contractor's name and address. Quality Roofing Contractor; Inc.
13800 N.W. 1st Avenue Miami, F1 33168
5. Surety: (Payment bond required by owner from contractor, if any)
Name and address. N/A
Amount of bond $ 00
6. Lender's name and address: N/A
7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as
provided by Section .713.13(1)(a)7., Florida Statutes,
Name and address. N/A
8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided
in Section 713.13(1)(b), Florida Statutes.
Name and address. N/A
9. Expiration date of this Notice- of Commencement: (the expiration date is 1 year from the date of recording unless a
different dat is specified)
er4 ( j
Signature of Owner
Print Owner's Nam
Sworn to and *subscribed before me this
Notary Public' / /(Print Notary's Name
My commission expires:
123.01.52 PAGE 4 10/D4
NOTARY PUB .IC-STATE OF FLO • t A
Marylou Herman z
cCuuuus5iou #DH93y046
�,,.•° Expires: OCT.10, 2013
BONDED THRU ATLANTIC BONDDIG CO.,INC.
Prepared by Marylou Hernandez
Quality Roofing Contract
,address: 13800 N.W. 1st Ave
Miami, Florida 3316f
(305) 953 -3333
' ROOF ASSEMBUES AND ROOFTOP STRUCTURES
u TIE
OCT L
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Informations pr ��� 19a9 Master Permit No. Process No. -�"
Contractor'sName Quality Roofing Contractor, Inc.
Job Address 235 Grand Concourse
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile IX Mortar /Adhesive Set Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Prescriptive BUR -RAS 150
ROOF TYPE
❑ New Roof DI Reroofing ❑ Recovering ❑ Repair ❑ Maintenance
ROOF SYSTEM
INFORMATION
Steep Sloped Roof Area (SF) 3 5 0 0 s g f tTptal (SF) 3 5 0 0 s g f t.
Low Slope Roof Area (SF) N/A
Section B (Roof Plan)
Sketch a II a all levels and sections, roof drains, scuppers, overt"'
Inclu 1i - , sl t c ions and levels, clearly identify dimensions of ete
pare
Miami Shores Village
INVRIZSTM
•� overfIo drains. DATE
ZONING DEPT
BLDG DEPT
SU ECT TO COMPLIANCE WITH ALL FEDERAL
BCafiw ,. - REGULATIONS
30
N
A
a0
-4
15.34 2010 FLORIDA BUILDING CODE — BUILDING
Flat White Saxony 900
' ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
15.36
Florida Building Code Edition 2010
High - Velocity Hurricane Zone Uniform Permit Application Form.
Section D (Steep Sloped Roof System)
Roof System Manufacturer: Boral Roofing, LLC
Notice of Acceptance Number: 12- 0222.03
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculationsp j. -39.1 P2: -68.1 p3: -100.7
Roof Slope:
3 : 12
Steep Sloped Roof System Description
Deck Type:
wood 1 X 6
Type Underlayment:
Ridge Ventilation?
N/A
Insulation:
(1) 301b. ASTM D -226
N/A
Fire Barrier:
Mean Roof Height: 16
N/A
Fastener Type & Spacing:
Adhesive Type:
�� p
1 1/4" R/S nails 2 row lo/
self adhering
Type Cap Sheet:
Polystick TU Plus
Roof Covering:
Type & Size
Drip Edge:
3 X 3 26 ga.
galvanized
1
2010 FLORIDA BUILDING CODE — BUILDING
■
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
High - Velocity Hurricane Zone Uniform Permit Application Form.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or2. Compare the values for Mr with the values from Mf. If the Mi. valnes are greater than or
equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127"
0.1.739.1 xx .313 = 12.23) -Mg: 8.03 =M142'
x a .313 .21.32). Mg: 8.03 =M213' 29
(p3, 100.7x?, .313 .31.52) - Mg. 8.03 = 323.49
Product Approval Mf 118.9
Product Approval Mf 118.9
Product Approval Mf 118.9
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height ->
Roof Slope 4
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
322
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
282
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals.
For Uplift based tile systems use Method 3. Compared the values for F with the values for Fr. If the F'values are greater than or equal to the Fr values,
for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Pea RAS 127"
(PI' x L = x w: = 1-W: x cos 0 = Fri Product Approval F'
(P2: x L = x w: = ) - W: x cos 0 = Fr2 Product Approval F
(P3: x L = x w: = ) - W: x cos 0 = Fr3 Product Approval F'
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
PI or P2 or P3
RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE7
Mean Roof Height
11
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
x
Product Approval
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Mg
Calculated
Minimum Attachment Resistance
F
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length
W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
2010 FLORIDA BUILDING CODE - BUILDING 15.37
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1. ?- Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system).
3. Common roofs: Common roofs are those which have no visible delineation between neighboring
units (Le., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or
owner should notify the occupants of adjacent units of roofing to be performed.
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appearance.
5. °' Ponding water: The current roof system and /or deck of the building may not drain well and may
cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. VZ / Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of the
oof.
Own- Agent's Signature
Revised on 7/9/2009 LD
Date
62-2e
Contractor Signature Date
MIAMI•
COUNTY
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.miamidade.gov /pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Saxony 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA #07- 0711.03 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 1 of 8
ROOFING ASSEMBLY APPROVAL
Category: Roofmg
Sub - Category: Roofmg Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This NOA approves a system using Saxony 900 (Shake, Slate & Split Shake) Concrete Roof
Tile, as manufactured Boral Roofmg LLC in Lake Wales, FL. and described this Notice of
Acceptance. For locations where the pressure requirements, as determined by applicable Building
Code does not exceed the design pressure values obtained by calculations in compliance with RAS
127 using the values listed in the installation section herein. The attachment calculations shall be
done as a moment based system..
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description,
Saxony 900 1= 17" TAS 112 Flat profile, interlocking, high -
w = 13" pressure extruded concrete roof tile
1- 5/32" thick Slate equipped with two nail holes. For
direct deck or battened nail -on, mortar
set or adhesive set applications.
Trim Pieces TAS -112 Accessory trim, boosted Barcelona,
1- 9/32" thick Shake &
Split Shake
Length: varies
Width: varies
varying thickness
2.1 MANUFACTURING LOCATION
2.1.1. Lake Wales, FL.
2.2 SUBMITTED EVIDENCE:
Test Agency
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Test Identifier
7161 -03
Appendix III
94 -084
94 -060A
concrete roof pieces for use at hips,
rakes, ridges and valley terminations
manufactured for each tile profile.
Test Name/Report Date
Static Uplift Testing
TAS 102 & TAS 102(A)
Static Uplift Testing
TAS 101 (Mortar Set)
Static Uplift Testing
TAS 101 (Adhesive Set)
Dec. 1991
May 1994
March, 1994
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 2 of 8
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
Atlanta Testing & Engineering,
Inc.
Celotex Corporation Testing
Service
Celotex Corporation Testing
Service
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
25- 7183 -6
25- 7183 -5
25- 7214 -1
25- 7214 -5
7161 -03
Appendix II
Letter Dated Aug. 1,
1994
P0631 -01
P0402
Project No. 307025
Test #MDC -77
R1.894
R2.894
R3.894
520109 -1
520111 -4
520191 -1
Evaluation
Calculations
Evaluation
Calculations
Evaluation
Calculations
Static Uplift Testing
TAS 102
(2 Quik -Drive Screws,
Direct Deck)
Static Uplift Testing
TAS 102
(2 Quik -Drive Screws,
Battens)
Static Uplift Testing
TAS 102
(1 Quik -Drive Screw, Direct
Deck)
Static Uplift Testing
TAS 102
(1 Quik -Drive Screw,
Battens)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Wind Driven Rain
TAS 100
Physical Properties
TAS 112
Static Uplift Testing
TAS 101
Static Uplift Testing
TAS 101
25 -7094
25 -7496
25 -7584
25- 7804b -8
25- 7804 -4 & 5
25- 7848 -6
Feb. 1995
Feb. 1995
March, 1995
March, 1995
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
Oct. 1994
Aug. 1994
Dec. 1998
March 1999
February 1996
April 1996
December 1996
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 3 of 8
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Nutting Engineers
Evaluation 25 -7183
Calculations
Evaluation Aerodynamic Multipliers
Calculations
Calculations Two Patty Adhesive Set
System
Evaluation Restoring Moments Due to
Calculations Gravity
130 TAS 112
March 1995
January 2007
April 1999
February 2007
January 2007
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with the applicable Building Code.
4. INSTALLATION
4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be
installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and
RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight -W (Ibf)
Length -I (ft)
Width -w (ft)
Saxony 900
Slate, Shake & Split Shake
11.5
1.417
1.08
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 4 of 8
Table 2: Aerodynamic Multipliers - a, (ft3)
Tile
A, (ft3)
A, (ft3)
Profile
Batten Application
Direct Deck Application
MonierLifetile Saxony 900
0.289
0.313
Slate, Shake & Split Shake
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 4 of 8
Table 3: Restoring Moments due to Gravity - Mg (ft-lbf)
Tile
Profile
2 ":12"
3 ":12"
4 ":12"
5 ":12"
6 ":12"
7 ":12" or
greater
Saxony
900
Slate,
Shake &
Split
Shake
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
7.16
8.12
7.08
8.03
6.97
7.91
6.82
7.74
6.65
7.55
6.46
7.34
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Saxony 900
Slate, Shake &
Split Shake
2 -10d Ring Shank Nails
30.9
38.1
17.2
1 -10d Smooth or Screw Shank Nail
7.3
9.8
4.9
2 -10d Smooth or Screw Shank Nails
14.0
18.8
7.4
1 . #8 Screw
30.8
30.8
18.2
2 . #8 Screws
51.7
51.7
24.4
1 -10d Smooth or Screw Shank Nail
(Field Clip)
24.3
24.3
24.2
1 -10d Smooth or Screw Shank Nail
(Eave Clip)
19.0
19.0
22.1
2 -10d Smooth or Screw Shank Nails
(Field Clip)
35.5
35.5
34.8
2 -10d Smooth or Screw Shank Nails
(Eave Clip)
31.9
31.9
32.2
Table 5: Attachment Resistance Expressed as a Moment Mf (ft -Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
MonierLifetile Saxony 900
Slate, Shake & Split Shake
Adhesive
31.32
1 See manufactures component approval for installation requirements.
2 Dow Chemical TileBond Average weight per patty 13.9 grams.
Polyfoam Product, Inc. Average weight per patty 8 grams.
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 5 of 8
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
MonierLifetile Saxony 900
Slate, Shake & Split Shake
Polyfoam PolyProm
118.9'
Polyfoam PolyProTM
40.44
3 Large paddy placement of 45 grams of PolyProm".
4 Medium paddy placement of 24 grams of PolyProTM'.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
MonierLifetile Saxony 900
Slate, Shake & Split Shake
Mortar Set'
43.95
5. Tile -Tite Roof Tile Mortar
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
detailed below, or following statement: "Miami -Dade County Product Control Approved ".
LABEL FOR SAXONY 900 TILE (LAKE WALES FL PLANT)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 6 of 8
NAIL HOLES --
PROFILE DRAWING
17"
WATERLOCK
13"
SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL)
1 5/32 " (slate)
1 9/32 " (shake)
OVERLAY
MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SPLIT SHAKE MODEL)
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 7 of 8
MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SHAKE MODEL)
END OF THIS ACCEPTANCE
NOA No.: 12- 0222.03
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 8 of 8
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315 -2590 F (786) 315 -2599
wwvw.miamidade.eov /asera
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the
right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA # 11- 0601.10 and consists of pages 1 through 8
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 1 of 8
ROOFING COMPONENT APPROVAL
Cateeorv: Roofing
Sub- Cateeorv: Underlayment
Material:
SBS , APP Self - Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick MTS
underlayment
Manufacturing Location
#2
Polystick IR -Xe
underlayment
Manufacturing Location
#1 & #2
Polystick TU
underlayment
Manufacturing Location
#1 &: #2
Polystick TU Plus
underlayment
(Surface Printing)
Manufacturing Location
#2
Polystick TU P
underlayment
Manufacturing Location
#2
Polystick Tile Pro
Manufacturing Location
#2
Polystick Dual Pro
Manufacturing Location
#2
Dimensions
Roll:
65'8" x 3'3-3/8"
60 mils thick
Roll:
65' x 3'33/8"
Or 65'x 3'
60 mils thick
. Roll:
32' 10" x 3'33/8"
100 mils thick
Roll:
65'.x 3'3 3/8"
80 mils thick
Roll:
32'10" x 3'33/8"
130 mils thick
Roll:
61' x 3'33/8"
60 mils thick
Roll:
61' x 3'3-34"
60 mils thick
Test Product
Specification Description
TAS 103 A homogeneous, rubberized asphalt
waterproofing membrane, glass fiber reinforced
with polyolcfmic film on the upper surface for
use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
TAS 103 and A fine granular /sand top surface self- adhering,
ASTM D 1970 APP polymer modified, fiberglass reinforced,
bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof file underlayment.
TAS 103 and A heavy granuled surface self adhering, APP
ASTM D 1970 polymer modified, fiberglass or polyester
reinforced, bituminous sheet material for use as
an underlayment in sloped roof assemblies.
Designed as a a roof file underlayment.
TAS 103 and A rubberized asphalt self-adhering, glass -
ASTM D 1970 fiber /polyester reinforced waterproofing
membrane. Designed as a metal roofing and roof
tile underlayment.
TAS 103 and A rubberized asphalt waterproofing membrane,
ASTM D 1970 glass- fiber /polyester reinforced, with a granular
surface designed for use as a tile roof
underlayment.
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
A rubberized asphalt self-adhering, glass -
fiber /polyester reinforced waterproofing
membrane. Designed as a metal roofing and roof
tile underlayment.
A rubberized asphalt self-adhering, glass -
fiber /polyester reinforced waterproofing
membrane. Designed as a metal roofing and
roof file underlayment.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency' Test Identifier
Exterior Research & Design, LLC 11756.04.01 -1
11756.08.01 -1
02202.08.05
Trinity ERD P5110.08.07
P10870.09.08 -R1
P10870.04.09
P33360.06.10
P33370.03.11
P33370.04.11
P36900.09.11
P37300.10.11
PRI Asphalt Technologies PRI01111
PUSA - 005 -02 -01
PUSA- 018 -02-01
PUSA- 035 -02-01
PUSA -033 -02-01
PUSA- 055 -02 -02
PUSA - 083 -02 -01
PUSA- 089 -02-01
Momentum Technologies, Inc. JX20H7A
RX14E8A
DX23D8B
DX23D8A
Test Name/Report Date
TAS 103 04/27/01
ASTM D 1970 08/14/01
TAS 103 08/29/05
TAS 103 08/29/07 •
TAS 103 12/04/08
TAS 103 /ASTM D4798 & G155 04/13/09
ASTM D1970 07/01 /10
TAS 103 03/02/11
ASTM D 1623 04/26/11
TAS 103 /ASTM D4798 & G155 09/01/11
TAS 110 /ASTM D4798 & D1970 10/19/11
ASTM D 4977 04/08/02
ASTM D 4977 01/31/02
ASTM D 2523 07/14/03
TAS 103 09/29/06
ASTM D 1970 01/12/06
TAS 103 12/10/07
TAS 103 06/30/08
TAS 103 /ASTM D4798 & G155 07/06/09
TAS 103 /ASTM D4798 & G155 04 /01/08
TAS 103 /ASTM D4798 & G155 11/09/09
TAS 103 /ASTM D4798 & G155 02/18/10
TAS 103 /ASTM D4798 & G155 02/18/10
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04 /05/12
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non-insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self-adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 -1/2" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks; chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04 /05/12
Page 4 of 8
GENERAL ',MUTATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles,
non - structural metal roofimg, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be
used in all the previous assemblies listed except metal roofing.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations (days)
Polystick MTS
MTS
IR-Xe
TU
TU Plus
TU P
Tile Pro
Dual Pro
Winter Haven, FL.
180
180
180
180
180
180
180
Hazelton, PA.
N/A
30
30
180
N/A
N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N -3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of-Acceptance. Polystick TU, TU Plus, and Tile Pro may be used in both adhesive set
and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically
fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile
applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Polystick IR-Xe
Polystick TU, TU
Plus, TU P, Tile Pro
Flat Tile
Prohibited without battens
5:12
No limitation
Profiled Tile
Prohibited without battens
Prohibited
No limitation
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04/05/12
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro
may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU
Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If
Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift
resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04 /05/12
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back - nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6'/a "/12 ", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric
Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of
repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over
the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The
repair should be installed in such a way so that water will run parallel to or over the top of ail laps of the
patch.
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894 - 4563.
NOA No.: 11- 1229.01
Expiration Date: 09/13/16
Approval Date: 04 /05/12
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894 -4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF = .I' S ACCEPTANCE
NOA No.: 11- 1229.01
Expiration Date: 09 /13/16
Approval Date: 04 /05/12
Page 8 of 8
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
3M Company
3M Center Building 0220- 05 -E-06
St. Paul, MN. 55144 -1000
MIAMI -DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175 -2474
T (786) 315 -2590 F (786) 315 -2599
www.miamidade.Eov /pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the 'requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3MTM 2- Component Foam Roof Tile Adhesive AR-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12- 0228.18
Expiration Date: 05 /10/17
Approval Date: 05/10/12
Page 1 of 7
r
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3Mrm 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as
determined by applicable building code, does not exceed the design pressure values obtained by calculations in .
compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles
system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a
moment based system for single patty placement, and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product
3Mrm 2- Component Foam
Roof Tile Adhesive AH-
160
Foam Dispenser RTF1000
ProPack® 30 & 100
Dimensions
N/A
N/A
N/A
Test
Specifications
TAS 101
Product Description
Two component polyurethane foam adhesive
Dispensing Equipment
Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160
roof file adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property
Density
Compressive Strength
Tensile Strength
Water Absorption
Moisture Vapor Transmission
Dimensional Stability
Closed Cell Content
Test
ASTM D 1622
ASTM D 1621
ASTM D 1623
ASTM D 2127
ASTM E 96
ASTM D 2126
ASTM D 2856
Results
1.6 lbs. /ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 LbsJFt2
3.1 Perm / Inch
+0.07% Volume Change @ -40° F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
86%
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 2 of 7
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94 -060 TAS 101 04/08/94
257818 -1PA TAS 101 12/16/96
25- 7438 -3 SSTD 11 -93 10/25/95
25- 7438 -4
25- 7438 -7 SSTD 11 -93 11/02/95
25 -7492 SSTD 11 -93 12/12/95
Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93
Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94
01- 6739 -062b[1] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96
Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98
528454 -9 -1
528454 -10 -1
520109 -1 TAS 101 12/28/98
520109 -2
520109 -3
520109 -6
520109 -7
520191 -1 TAS 101 03/02/99
520109 -2 -1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3M rm 2- Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
11
F: - W
F'- 2j
MS
APPROVED
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 3 of 7
INSTALLATION:
1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160.
2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient
attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in
compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "N' component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0
(B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No
other settings shall be approved.
6. 3MTM 2- Component"Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or
ProPacke4 30 & 100 dispensing equipment only.
7. " 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH -160 has been dispensed.
9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in
accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted
herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Single Paddy Weight
Min. (grams)
Two Paddy Weight per
paddy Min. (grams)
Flat, Low, High Profiles
#1
35
N/A
High Profile (2 Piece Barrel)
#1
17 /side on cap and 34 /pan
N/A
Flat, Low, High Profiles
#2
24
N/A
Flat, Low, High Profiles
#3 _
8
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 4 of 7
LABELING:
All 3MTM 2- Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
1) Pig enough adhesive to achieve 17 to 23 234's tar
square inches Incontaetwiththepanth steep pitchapp2eadona
2) Tum covers upslde down. Piece adhesive 1i2tn.
To1h6 From outside edge of cover the.
Then install the the
NOA No.: 12- 0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 5 of 7
ADHESIVE PLACEMENT DETAIL 2
• SINGLE PATTY
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
END OF THIS ACCEPTANCE
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 7 of 7
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 179785 Permit Number: RF -10 -12 -1900
Scheduled Inspection Date: March 08, 2013
Inspector: Bruhn, Norman
Owner: CARNEY, MIKE ANDROBIN
Job Address: 235 GRAND CONCOURSE
Miami Shores, FL 33138-
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Permit Type: Roof
Inspection Type: Up Lift Report
Work Classification: Tile
Phone Number (305)758 -9980
Parcel Number 1132060133620
Phone: (305)953 -3333
Building Department Comments
RE ROOF TO A NEW TILE ROOF
Infractio Passed Comments
INSPECTOR COMMENTS
False
Inspector Comments
Passe --,�J
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
March 07, 2013
For Inspections please call: (305)762 -4949
Page 2 of 4
n . - 1c
F•I•E•
FLORIDA INTERNATIONAL ENGINEERING
&TESTING LAB
INSIGHT•INNOVATION•INTEGRATION
Florida International Engineering and Testing Lab LLC
16701 SW 117 Avenue, Miami, FL 33177
Telephone: (305) 378- 1991 -Fax: (305) 378 -1997
Miami -Dade Lab Certification # 07- 0612.11 -State of Florida ca #27273
Owner's Name:
Job Address:
Roofing Contractor:
Permit Number: KV. op • t2.- °6, ®o Type of Tile: E''6tx'Lr d� I�t�'° F®x.s4
Approximate Roof Height: ', 0 feet Slope: V: t t Approximate Square Footage: 1, ti 0 0 ft2
Type of Access to Roof: co"- Ladder
OtherRequired Testing Fore: 35 lbs. Testing Equipment: F.G.E. 10 x Shi po Instrument
Date Installed: 'Z (Il i b Date of Inspection: '2�0
SITE SPECIFIC INFORMATION
.Ireilk-w( ) J5-tr
TEST RESULTS
P= PASS, F= FAIL
Test
Location
P or F
Test
Location
P or F
Test
Location
P or F
Test
Location
P or F
Test
Location
P or F
1
��7i
21
`i�
41
l t
61
:�
81
a.
2
22
42
62
•
82
3
23
43
63
83
4
24
44
64
84
5
25
45
65
85
6
26
46
66
86
7
27
47
67
87
8
28
48
68
88
9
29
49
69
89
10
30
50
70
90
11
31
51
71
91
12
32
52
72
92
13
33
53
73
93
14
34
54
74
94
Jl
`
15
35
55
75
95
16
36
56
76
96
17
37
57
77
97
18
38
58
78
98
19
39
59
79
99
20
a
40
�
60
e
80
/
100
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST.
ADDITIONAL TEST INFORMATION
Perimeter Width: 61 ft
Area
Units or ft2
No. of Tests
Perimeter
11 lop
34
Field
1 o C 90
Corners
'1.2
7.2
Hips & Ridges
4® Z4/ p
l t
RESPECTFULLY SUBMITTED BY:
Vma
Vinayagar M. Balakrishnan V Gy(
State of Florida Lic # 63107
z3
■ susisall *ari alma I Emit IiI its I:I1 nil IIIIIRass H ass aRI
aa. .a.aa .M1111a# *aaM MAMIWA a - i 11
111111111111111111111.1111111.1111112.111111111111101NNWPAPS113111111111
miansummassikatimusainirmaxiiiiillarMEPAIMPHINIREIR
--- 111111 ,2 +- -,' -.rte -- -- /- ; ir.071 -. 4.% mmaa
ssi sl►i 111 111 11 %IQSP ` E ` I1
111111 sisllt iC'1 S97 :4 UR$ Ifs ' >:1i
1111111111111111111 TAIMPIIINNIM44411111111111111C1IIMr*greflialliiiiiiia
11111111111111111111111111,M!! ni r4 ', ' 11 1 ait'1i rgalli ISINS
1111121111111231111: LillerF-11111111101111
'm sawaiman2 rf tarainam 11111111111111111* ►i -RatinimminiMINIVIORMI
■■�s11[ l
-- ----- itwymrriaii # �ss.��sMifi� ass s san s
RLIs -ss s I UR l `1 1 1 . 1 A 2a,aam n m saitamanu us ■ss ulana a usarnSenusstimmaana
satl ss' 1 � s k n i!s iass ass � ll
uiiisisv '1' t !'i1m,i1 fit i m ilk 1 easai�`ass
1111!111 111 #1iii iiaguitsiitr, <. �[1� � � �
ana ann II lag II'RUI RIrr4IsIis ill u Era* irma
ancosocianassincanasausiemiancumasamminammana
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: I NS P- 179780
Scheduled Inspection Date: November 16, 2012
Inspector: Rodriguez, Jorge
Owner: CARNEY, MIKE ANDROBIN
Job Address: 235 GRAND CONCOURSE
Miami Shores, FL 33138-
Permit Number: RF -10 -12 -1900
Project: <NONE>
Contractor: QUALITY ROOFING CONTRACTORS INC
Permit Type: Roof
Inspection Type: Renailing Affidavit
Work Classification: Tile
Phone Number (305)758 -9980
Parcel Number 1132060133620
Phone: (305)953 -3333
Building Department Comments
RE ROOF TO A NEW TILE ROOF
Infractio
Passed Comments
INSPECTOR COMMENTS
False
Inspector Comments
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
November 16, 2012
For Inspections please call: (305)762 -4949
Page 4 of 17
RE: Permit# RF -1 0 -12 -1 900
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
INSPECTION AFFIDAVIT
DATE: 11 /8/2012
Carlos Arocho licensed as a (n) Contractor / Engineer / Architect,
(Print name and drde License Type)
License #: 0 0 0 01 7 8 8 9.
FS 468 Building Inspector
On or about November 8, 2012 , I did personally inspect the roof deck nailing and
(Date & time)
Secondary water barrier work at 235 Grand Concourse Miami Shores, F1 '3'3 1 '38
(Complete Job Site Address)
Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit
Manual (Based on 553.844 F.S)
Signature
State of Florida
County of Dade:
The undersigned, being the first duly swom, deposes and says that he /she is the contractor for the above property
mentioned.
Swom to and subscribed before me this
�J% %