Loading...
RF-13-204Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: I NS P- 193318 Permit Number: RF -2 -13 -204 Scheduled Inspection Date: June 11, 2013 Inspector: Rodriguez, Jorge Owner: ASAAD, REDA Job Address: 576 NE 97 Street Miami Shores, FL 33138- Project: <NONE> Contractor: AG STAR CONSTRUCTION INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number (240)988 -8661 Parcel Number 1132060171510 Phone: (305)457 -9970 Building Department Comments RE ROOF FLAT AND TILE ROOF Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 185104. June 11, 2013 For Inspections please call: (305)762-4949 Page 26 of 27 R March 13, 2013 a i A -1 CONSULTING ENGINEERS, INC F STRUCTURES CONSULTING UPLIFT TEST EXPERTS LAB. CERTIFICA'1'1ON No.01- 1224 -5 4383 SW 70 CT, M IAMT.F L.33155 '1'EL.305- 740 -9550 FAX.305- 740 -9550 City of Miami Shores Building and Zoning Dept. RE: 576 NE 97 ST Miami Shores, FL 33138 Dear Building Official: I have inspected the above referenced project and the following is a report of my findings: ROOF FRAMING — I conducted a partial visual inspection of the interior roof frame, I observed the existing 2" x 8" Wood Joist @ 12" connected to Tie Beam with strap. ROOF S H N;ATHINGS: Several areas with partial deterioration in the Roof Sheeting were replaced with 5/8" CDX plywood over all Truss nailed with 8d Ring Shank nails at 6" O.C. and at 4" 0.0 at Perimeter edge and corners and re- nailed in the areas where no replacement was needed. The roof frame is in compliance with the code at time the structure was permitted (1937). This report is based on limited visual review of existing structural components. Attached Photos) If I could be of any further assistance in this matter please do not hesitate to contact me. Sincerely, Jose A. P.E. Li o: 03150 Seal, and Signature Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 185103 Permit Number: RF -2 -13 -204 Scheduled Inspection Date: June 06, 2013 Inspector: Rodriguez, Jorge Owner: ASAAD, REDA Job Address: 576 NE 97 Street Miami Shores, FL 33138- Project: <NONE> Contractor: AG STAR CONSTRUCTION INC Permit Type: Roof Inspection Type: Up Lift Report Work Classification: Tile /Flat Phone Number (240)988 -8661 Parcel Number 1132060171510 Phone: (305)803 -8048 Building Department Comments RE ROOF FLAT AND TILE ROOF Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments June 06, 2013 For Inspections please call: (305)762 -4949 Page 7 of 38 CONSUTA$ 5, • : A -1 CONSULTING ENGINEERS, INC ROOF STRUCTURES CONSULTING ROOF PROBLEMS ? ?? UPLIFT TEST EXPERTS L� Owner's Name: /G Job Address: Roofing Contra Type of Tile: ON SITE CONCENTRATED UPLIFT LOAD TESTING ROOF TILE IN ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE TAS No. 106 SITE SPECIFIC INFORMATION �G Asa'ac/ Permit #2 —2/ 3--2® / Approximate Roof Height: /2" feet Roof Pitch: 3; /2- Type of Access to Roof: ✓ Scaffolds Date installed: Ladder Other Approximate Square Footage of Roof: ft 2 Required Testin F rce: lbs. Testing Equipment: F.G.E. 100 Date Tested: 4.3 TEST LOCATION UPLIFT PULL TEST TEST LOCATION UPLIFT PULL TEST TEST LOCATION UPLIFT PULL TEST TEST LOCATION UPLIFT PULL TEST TEST LOCATION UPLIFT PULL TEST TEST LOCATION UPLIFT PULL TEST 1 PI 26 �� 51 I'T" —` . -3 76 101 126 2 27 52 77 1b2 127 3 28 53 78 103 128 4 29 54 79 104 129 5 30 55 80 105 • 130 6 31 56 81 106 131 7 32 57 82 107 132 8 33 Oft/' 83 108 133 9 34 59 84 109 134 10 35 60 85 110 135 11 36 61 86 111 136 12 87 62 87 112 137 13 38 63. 88 113 138 14 39 64 89 114 139 15 40 65 90 115 140 16 41 66 91 qq 1 41114111 141 17 42 67 92 i 11 77 142 18 43 68 93 • k 1 :18 143 19 44 69 94 144 20 45 70 95[x.1 °t m iiii gns 5 21 46 71 96 @ ° 121 146 22 47 72 97 147 1.22 23 48 73 981D) miq,; _123 148 24 49 74 99 124 _ 149 25 T7AS_ 50 75 • 100 125 150 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CON- TROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. THIS REPORT SUBMITTED BY: Jose A. Martinez P.E. # 031509 A -1 CONSULTING EN Lab. Certificatio d3.7- 0306.03 enews: 01- 1224.05 4383 S.W. 70th Ct, Miami, Florida 33155 • Telephone (305)740 -9550 • Fax (305) 740 -9550 ENGLISH: Cell (305) 609 -6388 • SPANISH: Cell (305) 498 -9804 NE 97 ST ., G STAR GONSTRUC -.,.. HANSON DOUBLE ROLL ROLL feet m of access to _ a e square Required testing fore . Date tested: OF R OF Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 185104 Permit Number: RF -2 -13 -204 Scheduled Inspection Date: June 06, 2013 Inspector: Rodriguez, Jorge Owner: ASAAD, REDA Job Address: 576 NE 97 Street Miami Shores, FL 33138- Project <NONE> Contractor: AG STAR CONSTRUCTION INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number (240)988 -8661 Parcel Number 1132060171510 Phone: (305)803 -8048 Building Department Comments RE ROOF FLAT AND TILE ROOF Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments 15Rok (7) JPP d 2 rn;(De ATEb ; June 06, 2013 For Inspections please call: (305)762 -4949 Page 8 of 38 Miami Shores Village Building Department '10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION 91 EV177 13 ji o aU`ma ®m ®®°0•m - -- Permit No. t'' 1 va D4- Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: 576 0 6 q? City: Miami Shores County: Miami Dade Zip: ?'3 I 36 Folio/Parcel #: I) " 32-0 6. 0 /7 —15/0 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): liadlq' Alizu.o-�tt< mad Phone#: 2033' — 3g3.— Address: .,1) 6 �../0 6 9-7 5T City: t�Aq„ I'C%S State: Zip: 33/5B Tenant/Lessee Name: Phone#: Email: nn @ dc-e fitek CONTRACTOR: Company Name: AC S66- 6- (37&S4TUC 0,3 / /o c-- Phone#: 1 603 SO r Address: /6i1 tt) -fir 37 2 City: j.kic(�if'1 ( r / State: FL Zip: 331 Z5 Qualifier Name: P� . ( Y� aR 1 d 4," .e,1_ Phone#: 007- ? ? -2 State Certification or Registration #: CCC 13 2? 0 Z 9 Certificate of Competency #: Contact Phone # :C3) CY.3 —507 C) Email Address: 3OdO( pc( e IQtira°, (4) DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ '23I 000 w ®° Square/Linear Flage of Work: Type of Work: C]Addition teration UNew 1 � /Replace ` UDemolition Description of Work: i41 e 0 C7 -T ) �,� + , . _ ir 00 'F- . Color thru tile: airr . �....�a .............. *ear ****** * **.*** � s * * ** *** * *** * * *** e".*** * * * *. ***** ******* Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ _ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ S Y) .s.(p Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature The foregoing instrument was acknowledged before me this 4444 The fore day of ;bflAAY\, 201?z, by NAQi I A kl WI Y I l —if;SllPArlay of Contractor instrument was acknowledged before me this 4 20a, by At k. Qtck 'mZ/, who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print My Commission Expires: Sign: Print My Commission Expires: + **** ******** ******* * ** * *** *** *** ** ** r**** ******** * *** *** ** **** * **************** acv ** ***way * ** ***** * *** APPROVED BY 7� 34�' 3 Plans Examiner Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09) 1 111111 11111 11111 11111 11111 11111 11111 1111 1111 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION 0 PERMIT NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: TAX FOLIO NO.113 6 /7 /570 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street I address 2. Description of improvement . Owner(s) name.and address: FM 2013R0089812 Bk 28472 P9 2928i (1Ps) RECORDED 02/04/2013 11 :33r24 HARVEY RUVIHr CLERK OF COURT MIAMI -DADE COUNTY? FLORIDA LAST PAGE Interest in property: ®� 6 ,yLc�✓ Name and address of fee simple ' eho der. 4. Contractor's name and address: 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: b 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: 9. Expiration date of this Notice of Commencement (the different date is specified) Signature of Owne Print Owner's Name NA ► l a Nom hi. L- Asaaci N Prepared by (0 �cloy' Sworn to and subscribed before me this 4414 day of OrtAG1 , 20 13 . Address: 1 t7 c(-43 f ° Notary Public: Print Notary's Name: My commission e s ftD-9,04 Elfiara^, Shores — — Master Permit No. Process NO. Contractor's Name Or Co STr A \ Florida Building Code Edition Troia:wow High Velocity Hurricane Zone Uniform Permit Appb141111111111, ctio Get:, :11 f IDATE Job Address 57G it)6 Ti s-r //fj; E'AL Or .1111,11 FY I. 'II' 91._ ROOF CATEGORY If Low Slope 0 Mechanically Fastened Tile Mortathdhesive Set Tibs 0 Asphaltic 0 Metal PaneVShingles 0 Wood inglesiShakes Shingles Are there 0 Prescriptive BUR-RAS 150 Gas Vent Stac190 Yes Li No' ROOF TYPE Type: NaturalD LPGX 0 New Roof d Re•Roofing Recovering 0 Repair Maintenance . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 18001 2100, 40_00' Section IS (Roof Plani Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Imminmsmsnmeammummummumummmossummummommumnammammmismomminmesimismummin rommaraummummemormismormirommummumummossommusammismommimmummummmummin misminsmommommimimmormsrmisuremmunnumummummummaramminsommummuirrimumar mummommummmumummemmirrommummummummingionsumummimmirssmsommisimmumumm swammiummommimmilsomammemmarmormsmissammemummimmunimmisismossmanomplusommum ammummommummismommumummassimmamommismworommommommoms MOMMONUMMOWOMENWOMMUM aMmommusinummummumerammommommormilmansammignamonswin mosimmimurrimmummanis Isommommemmummummummorsimminsmmummilammumeniminnsmansimmammumin suns cusacuc. cm ci .u.c cc cc cc succicu Immmenummumminimummummommummummarrommimmummorsommumpoimmmosommummour immommungummummissmammommumummummummummorimismorw- -.......ummummisma Immomommummsammammonsimmummiassimprummiannicocammummliiiimmimummissimminim mammommememommwarommurrimmannumnsimmumwmtwAmmansmweimmnimummummos mummaimmummilmummunim smiiimmimmisma— '- - - ■Iimmimerumcuminiumwmuns mum! pummummummumailm MMONIESSEMENXIMAROMMMOMMUMENNMI4OMMINUMA.),AmmamniMINIM IMffiNNIN giNUMEMENAMMOMMENUMMINIMMINIMMWIRMOMMERNMOMMUSIMM*AMMINAMMONIMUAMOMMUM INEMEMO manumpaimimmumpsimsposismommtimmummerwmpurarammiummmximpilimumm i MUM •ISMONIMIN viimmximminsimarrommarimmgmmermrimoraruccommorimmommullim .WOMEMOMUMNMM *SIMIMOMMEMMINORMISMIESMACNIUFAUMWUNCOOWWW0111WWWOU mill giamitsmswimmman mmoggim -- NV momminiMmOmmunammiamIMMAMONNOmulmalmmominilkeirOWOMIIIMMOMMMIManim "Amarillo XimmuMMMIKMamminal nommilmoursumminuommutrimftwommumosimmamommifffters mom cmgmassommarmummom SOMMIWOHMAMMOSMENNW10114111NOSIMMUNIMMXMLAMINSOMAAMMW SOM KWASEINNWMOUNNWISIONS MMMIN•OW4MM2NMEW ANOMOMINA*WROI ! - - . _ _ .,! KVIIIMMAMMO oplinummgrannnimpirnormilmininia IgArammonsimissimmismuipummresOpinsim mums inumpummusimowAwnimminximmimummummummomarlmommomnimmwprNmininim mums VaMMEMOMUNICII•MiU 11.2111111PIRMIWANNIPANIF m■41rnomMINIVMEN4MIONIMMIMMIONIMO IMMUMMUUOM, _ , _AOSCRIIMAMNAMMWalamMEM milliamomprimplosimmamormimmrs omprimmumwhisiniiiiiiiiiiiimormwAnamolimminwassammummummummillimmmismi us imis mommormaratowlmumummiumpossumimmespormiramismomairmuswarmingssimmim MN mli 111 INUMMOMMIMANNMWMENTWAIMOSIMEW/iMINIMONOWANEMONNIMOOMENTOMMInEWMONOM V IMMOMMIMMUAINWINUmplell ONNOMMUM•miliMUVA•1111411MONIIMMUM WOMINNOOMMOWn II sommormwommonnwsumumwmorAlevonruinumempoiLAmmirammmurs summimmirmarms soloommummimrsomm P. - .-Amumh7 is normisrmimboonimmunimummummemmiliimiiiinomMosimismarmsommaramossampo _ auiu,Ammiciamissisisimmarmommemmorm to umnsommosOmrlismummummlignmeminsiNmomponsmommommommarmimplimmeammiumm NMOMMINNEVISIMPAWMOMMINKOAMMMUMNrci*OmMUMIMOMOMUMNSUMMEMMONW umnimmummy minsimmuslomvAmaumimmoiormismarmOvIrommarmmlollimulaNNUmmim Wu smulmism NmummormsommwAsvms mow - _ . :x.00IUMSmoll MUM ONSOMENO omprowimmolousgvamm mounimilmummummommarmitiltikilialiminmem immumnpommisamims wpmminnOMMIVAMMUMBENJuswilimparAINUrrOmilmUlawn ummummo mummirmensminom milmaimmit _ . _7.101411MMEN664011111 MUMMMIONORMIN MMOMMOIMO mrsisimmumminorm sioniaMOMMIniliiiftiiitOWIMOMO limiligaMi MiMMEMMUEINISIMMUrnismil Timmunim 1 sismanammiNSIMPIIIMMInsimspa IIMOINOMNIMMEME IMEMENWOMM mENMMUM I Milmillifigi I mum immiwor mminmonimmil mommilimorm spingssimmisimmurgimmumpunimmumwom IMMO • IMMUMMIASNIMMOMMEM pgisprommumissmg mummmunram WOIMMNIXIM IMMUNIMmill I IMEXIMOMM MIMI AMOMMUMMIWW MAKNOWIROMUM ommiummarimmimmomminismompolimmom manummo INIMMOOMMWOMMIUMMUMMOSENSIMMOM imposimmomminommimmossuirng inammuum mararrimminummummums**MmuMmiwil mummOOMOmmallomsmomminsamcmws" 123_01-48 12/09 PAGE 2 TIONS 4 OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami -Dade County Building Department 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name AMC{A Ao0d2 K klctcl Property Address 5-)6> /V 7 Sr Roofing Permit Number Dear Building Official: I C4 04 ri 7- 1( connegtions of my building because: Qolci• certify that I am not required to retrofit the roof to wall UThe just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. UThe building was constructed in compliance with the provisions of the Florida Building Code (Fi3C) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). rty ar.I<Aga'. STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this day of , 20 (SEAL) /Personally known or Produced Identification When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. C:VJoaculacts ands ,vsgn npne Woofing Affidavit comp «426071111 .aw M • -, FDiADE COUNTY OWNER'S NOTIFICATION FORM SECTION 1524 HIGH VELOCITY HURRICANE ZONE - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initials in the designed space indicates that the item has been explained. Ki1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. al2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants and adjacent units of roofing work to be performed. al4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining its appearance. al5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida - licensed engineer or registered architect to eliminate the attic venting, shall not be required. Owner's /Agent's Signature: Contractor's Signature: Property Address- 123_01-197 12/09 Date. Permit Number 576 /U E qa7 ST INA Insulation Base Layer Size & Thickness: NA Section C MIAMI• Miami -Dade County HVHZ Electronic Roof Permit Form Section C Page (Low Slope Roof Systems) "l),4 crrinp rx(ellen(c (,t.ry Da)" RI! in the specific roof assembly componena if a component is not required, insert not applicable (n/a) in the text box. ROOF SYSTEM MANUFACTURER: Top Ply: I GAF MATERIAL COR I Product Approval (NOA): System Type: MN Wind Uplift Pressures, From RAS 128 or Sealed Calculations: (P1) Field: -42.8 (P2) Perimeters: (P3) Corners: psf -108.0 psf psf Maximum Design Pressure From NOA: Roof Slope: Parapet Walls: 0.50 Deck Type: EMI " : 12 Roof Mean Height: psf No 0 Yes Parapet wall Height: —5/8" Plywood- Support Spacing: Alternate Deck Type: Existing Roof: " o/c ft. EMI ISAME Fire Barrier: Vapor Barrier: NA Anchor Sheet: NA Anchor Sheet Fastener ! Bonding Material: Insulation Base Layer Fastener! Bonding Material: INA Insulation Top Layer Size & Thickness: NA Insulation Top Layer Fastener ! Bonding Material: ft. INA Base Sheet(s) & No. of Ply(s): I GAF GLASSBASE 75# (1) Base Sheet Fastener! Bonding Material: [1 -1/4 RS NAIL & TIN CAP 1 -5/8 Ply Sheet(s) & No. of Ply(s): GAF PLY IV (2) PLY 2 Ply Sheet Fastener ! Bonding Material: I HOT MOP ASPHALT TYPE IV GAF MINERAL CAP SHEET Top Ply Fastening! Bonding Material: Surfacing: GRANULES SINGLE PLY MEMBRANE: Single Ply Manufacturer / Type: INA Single Ply Sheet Width: No. of Single Ply 112 sheets: " 1/2 Sheet Width: Single Ply Membrane Fastening / Bonding Material: NA n FASTENER SPACING FOR BASESHEET ATTACHMENT ❑ SINGLE PLY MEMBRANE ATTACHMENT 1. Field: a 2. Perimeter: ° a/c @ Laps & Ea a " o/c @ Laps & 3. Corner: j " o/c @ Laps & rows a am a rows rows " o,c " o/c " o/c NUMBER OF FASTENERS PER INSULATION BOARD: 1. Field: fca 2. Perimeter: Insulation Fastener Type : 3. Corner I NA I WOOD NAILER TYPE AND SIZE: 1 X 8 FASCIAE I Wood Nailer Fastener Type and Spacing: EDGE & COPING METAL SIZES: Edge Metal Material: — Galvanized Metal — Edge Size: —3" face 26 ga.- - SELECT EDGE METAL HOOK STRIP SIZE -- Hook Strip Size: Edge Metal Attachment: 1 -1/4 RS NAIL 4 "OC Coping Material: — SELECT PARAPET WALL COPING MATERIAL -- Coping Size: Hook Strip Size: Parapet Coping Metal Attachment: — SELECT COPING METAL SIZE OR THICKNESS- -SELECT COPING METAL HOOK STRIP SIZE- Insulated Nailable•Deck With Edge Nailer MIAM>•DA,DE C : INTY "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Illustrate Components Noted and Details as Applicable: Top Ply ti 1 }1 Interplies Base Sheet Alichor Sheet s, it t i S 1,sy Roof Deck 1y,\ Base Layer i( of Insulation ._._: Top Layer _: of Insulation - Continuous Cleat Wood Nailer Roof Mean Height: Drip Metal: 14 ft. { 3X3 GALV 26G Continuous Cleat: NA Surfacing: GRANULES Top Ply: I GAF MINERAL CAP SHEET Top Layer of Insulation: NA Base Layer of Insulation: INA Wood Nailer: 1 X 8 FASCIAL BOARD Wood Nailer Fastening: 18D NAIL @ 16" Anchor Sheet: I N/A Deck Type: PLYWOOD 5/8 Tile Roof System 6 ` MIAMI•DADE AUNTY "Delivering Excellence Every Day" Roof System Manufacturer: Miami -Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System I HANSON ROOF TILE Notice of Acceptance Number (NOA): Ala 07/7.0? Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P1: -39.1 P 2: -68.1 P 3: -100.7 Maximum Design Wind Pressures, (From the NOA Specific system): psf Fill In the specific roof assembly components. If a component is not required, Insert not applicable (n/a) in the text box. Deck Type: Optional Insulation: Roof Slope: Roof Mean Height: "112" ft. Method of Tile Attachment: --Adhesive, Medium Paddy Polyfoam Polypro -- Alternate Method of Tile Attachment per NOA: 1N /A Drip Edge Size & Gauge: Drip Edge Material Type: Drip Edge Fastener Type: - -3" face 24 ga. -- -- Galvanized Metal -- 1-1/4" RS NAIL 4 "OC Hook Strip /Cleat gauge or weight: -- Select Hook Strip -- Optional Nailable Substrate: INA Optional Nailable Substrate Attachment: NA Basesheet Type: ASTM FELT 30# D226 Fastener Type for Basesheet Attachment: 1 -1/4 RS NAIL & TIN CAP 1 -5/8" Tile Underlayment (Cap Sheet ) Type: ASTM FELT 90# Tile Underlayment Attachment Method: 1 HOT MOP ASPHALT Tile Profile: HACIENDA CONCRETE TILE Section E MIAMIDADE COUNTY "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: P 2: P3: 100.7 x? xA x� 0.289 0.289 0.289 = ;11.30 - Mg ;6.80 =Mri: _ . _ Mg: 6.80. = Mr2: = 29.10 _ Mg, 6.80 = Mr3: 4.50 22.30 5 r� NOA Mf LOi• NOA Mf NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" SoOn For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. P1: P2: P3: x I: xl: xl: Description X w: x w: X w: - W: - W: x cos 0: = Fri: x cos 0: = Fr2: x cos 8: = Fr3: i Where to Obtain information to complete tile calculations Design Pressure Symbol Where to Find 5 NOA F' NOA F' NOA F' P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height Roof Slope H Job Site Aerodynamic Multiplier Restoring Moment due to Gravity Attachment Resistance Required Moment Resistance Minimum Attachment Resistance e x Mg Job Site Product Approval (NOA) Product Approval (NOA) Mf Product Approval (NOA) Mr Calculated F' Product Approval (NOA) Required Uplift Resistance Average Tile Weight Fr Calculated W Product Approval (NOA) Tile Dimensions 1= length w = width Product Approval (NOA) TGFU.R1306 - Roofing Systems Page 2 of 55 The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1h -in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C -15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in. thick periite board and deck with rosin paper (perlite/rosin paper /polystyrene /perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuard® RA" or 'Tapered EnergyGuard® RA" or "EnergyGuard® Composite RA" may be substituted for any Atlas polyisocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". "GAFGLAS® #80 Premium Base Sheet" may be used in any of the following systems. " GAFGLAS® Flex Ply 6° and "Tri -Ply® Ultra-Flexible Ply 6" are suitable alternates to " GAFGLAS® Ply 6 ". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "Fireshield MB" at 21h to 3- gal /100- ft2. "Ruberoid® Dual Smooth° may be used as an alternate to "Ruberoid® Mop Smooth" or "Ruberoid® 20" or "Ruberoid® 20 HT" "Ruberoid® Mop Smooth 1.5" may be used as an alternate to "Ruberoid® Mop Smooth" Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid® Heat Weld' SBS roofing membrane may be used in lieu of "Ruberoid® Mop" SBS products in any applicable Classification. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite / polyisocyanurate composite or perlite /urethane composite or wood fiber / polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type G1 or "GAFGLAS® Ply 4° or "Tri -Ply® Ply 4° or " GAFGLAS® Piy 6" hot mopped. Surfacing: — Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): — One or more layers perilte or wood fiber or glass fiber or polyisocyanurate or urethane or perlite /polyisocyanurate composite or perlite/urethane composite or wood fiber / polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type GI or "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet " or "GAFGLAS® EnergyCap"" TM' BUR Mineral Surfaced Cap Sheet." 3. Deck: NC Incline: 2 Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite /urethane composite, wood fiber /polyisocyanurate composite, phenolic, 2 -in. maximum. Ply Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4 ", "Tri -Ply® Ply 4" or "GAFGLAS® Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS® EnergyCap"" BUR Mineral Surfaced Cap Sheet." 4. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): — Red rosin paper, nailed to deck. Insulation (optional): — Any thickness perllte or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri -Ply® #75 Base Sheet° (may be nailed). Ply Sheet — One or more piles Type GI " GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or GAFGLAS® Ply 6 ". Cap Sheet: — One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri -Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS® EnergyCap"' BUR Mineral Surfaced Cap Sheet." Surfacing (optional): — "TOPCOAT® EnergyCote"°" applied at a rate of 2 -gal /100 -ft2. 5. Deck: NC Incline: 3 http: / /database.ul.com/cgi- bin /XYV/ template /LISEXT /1FRAME /showpage.htmi ?name =T... 2/23/2012 iVf kR {bhp BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NO'T'ICE OF ACCEPTANCE NI.OA) GAF Material Corporation. 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY, FLORIDA METRO•DADE PLACER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AID). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHD (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code: This product is approved as described herein, and has 'been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone ofthe Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. automatically .fly terminane endorsement of any product, for sales, advertising or any other purposes this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, the NOA is followed by the expiration date may be displayed in advertising literature. If any portion displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 gh 19. The submitted documentation was reviewed by Jorge L. Aecho. A NOA No.: 07- 1219.09 Expiration Date; 11/04/13 Approval Date: 03/20/0$ Page 1 of 19 Deck Type 1: Deck Description: System Type E: Wood, Non - insulated 19/32" or greater plywood or wood plank decks Base sheet mechanically fastened. stem Limitations shall apply. • AU General and Sys Barrier: (optional) Base sheet: Fastening Options: FiireQutrm Fire Barrier Coating, VersaShield1eNon Asphaltic Fiberglass Based Underlayment or SecurockT . GAFGLAS® #80 ULTIMArm Base Sheet, STRATAVENT® Eliminatarh Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® Heat -Weldor Smooth or RUBEROID® Heat-WeIdm 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4, GAFGLAS® Flex Ply", 6, GAFGLAS® ® #75 Base Sheet or any of above Base sheets attached to deck with approved annular and in two nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered 12" 0.0. in the field. (Maximum Design Pressure ,-.15 psf, See General Lbnhtatian #0 GAFGLAS® Ply 4, GAFGLAS®Flex Plym 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill Teem #12 standard, #14 or # 15 Screws and 3" Drill -Teem steel plate or Drill-Teem AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum D Pressure -45 ps , See General Ulan #7) GAFGLASS' Flex Ply"' 6, GAFGLAS® #75 Base Sheet nails and above in a sheets attached to deck with approved annular ring fastener spacing of 9" 0.0. at the 4" lap staggered and in two rows 9" o.c. in the field. ( Maaximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLASs #8OULTIMATm, RUBEROID41'20, RUBEROID® Mop Smooth, base sheet attached to deck with approved 1W' annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maxim Design Pressure -60 psf, See General Limitation #7) GAFGLAS® #15 Base Sheet or any of above Base sheets attached to deck with Drill -Teem #12 standard, #14 or # 15 Screws and 3" Drill-Teem steel plate or Drill-TecT AccuTrac Plates, 12" 0.0. in�i One n is in the 2" the sap. the The other rows are equally spaced approximately 9" (Maximum Design Pressure -60 psf, See General Limitation #0 Any of above Base sheets attached to deck approved annular ring shank nails and:3" inverted Drill- Term insulation plates at a fastener spacing the 4" tap staggered in two rows 9" in the field. (Maximum Design Pressure -60 psf, See General Limitation #77 NOA No.: 07- 121909 Expiration Dater 11104113 Approval Date: 0312OfOS rage 17 of 19 GAFGLAS® #75 Base Sheet or any of above Base sheets attached �� ate with or Drill -Teem #l2 standard, #14 or # 15 Screws Drill-Teem AccuTrac Plates, 8" o.o. in 4 rows. One ro is the the d si the e lap sheet. The other rows are equally spaced approximately Limitation #7) (M�dmttm Design Pressure --75 psf, See General Limit Ply Sheet: One or more plies of OAFGLAS® PLY 4, #80 ULT[MA, RTJBEROID® MOP Smooth or RUBEROID® 20 adhered in a full mopping approved ha applied within the EVT range and at a rate of 20-40 Ibs./sq. Sheet or Cap Sheet: (Optional) One ply of C� �6 S �°d ��' in a full Cap GAFGLAS® Enea'�� mopping of approved asphalt applied within the EVT range and at a. rate of 20 -40 Ibs.sq. Surfacing: (Optional, required if RUBBROID® MOP Smooth or RUBEROID ® 20 is top membrane) Install one of the following • ectivel in 1. Gravel or slag applied at 400 lbs.sq. and 300 br fs�l' #n a flood a flood coat of approved asphalt at 60 Ibsdsq. or apP coat of Leak Buster" Matriem 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFCiLAS4' Mineral Surfaced Cap Sheet, GAFOLA.Se Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq- 3. Leak Buster"' Matrix"' 303 Premium Fibered Aluminum Roof Coating,.at 13 gal./sq. 322, 4. Leak Buster"' Nom` 715 , Leak Buster= TOPCOAT° MB +, TOPCOAT° Flreshield Etasioiueric Roofing Meinnbrane, applied at Ito 1.5 gal /sq. 5. Leak Boter".1 Matrix't 602 MB Xtra Elastomeric Roofing Membrane, EnergyCotee roof doting applied at I to 1.5 galisq. 6. TOPCOAT' Surface Seal, TOPCOAT° Pireshiald* SB Solvent based Elastomeric Roofing Membrane applied at Ito 15 galJsq au Technologies Photovoltaic Laminate solar energy 7. Advance G am roof equipment installed in compliance with collector uxiliary manufacturer's specifications and applicable Building codes. Maximum Design Pressure: See Fastening Above NOA. Na.; 04219.09 Elptrafion Date: 11/04/13 Approval i)r g /1 e 18 of 19 WOOL? DECK SYSTEM L ATIONS. I A slip sheet is required with Ply 4 and Flex PlyTM 6 when used as a mechanically fastened base or anchor 1/4" or 'tZ" Type X gypsum board is acceptable to be installed directly over the sheet. j� 2. Minimum '/4 Dens Dec+= 4 Xp wood deck. GENERAL LIM%'PATIONS: Approved Roofing Materials Directory I. Fire classification is not part of this acceptance, refer to a current Appm for fire ratings of this product. compliance with • Insulation may be installed in multiple layers. The first layer shall be attached in tromp approved ` Approval guidelines. All other layers shall be adhered in a full mopping fd prov the asphalt applied App and at a rate of 20- �4()1bs sq., or mechanically attach asphalt applied within the EVT range ed asphalt, fastening pattern of the top layer acceptable for mechanical attachment. n applied in appt 3. All standard panel sizes are accep panel size shall be 4' x 4' maximum• anal required on all applications over closed cell foam 4. An overlay and/or recovery board insulation mopped. panel no recovery board is used the base sheet shall be „ " o.c.; or strip mopped 8 insulations when the base g with is fully p o ed asphalt, 12 diameter circles, 24 continuous applied using spot mopping each si laced every 12' in area of i e three rows, one at g of rte strips and s not acceptable. A 6" break sheet shall be p allowing rate in Asphalt application of either system shall be at a mini area of ventilation. Encircling of the P pressure of .45 psi. of each ribbon N to allow cross attached u s shall be limited to a maximum design p value of psf. i a l en spacing Note: Spot anion ad syste Characteristic Force (F) Fastenerspacing for insulation w h attachment Testing pplb ton Standard TAS 105. If the fastener value, as field- tested, lbf., as tested in compliance with table. entisbasedona testee are below for lbf. insulation tt attachment o attachment shall not be ? value listed t is within a specific minimum spacing for mechanical stance v ae in conjunction ccttz anchor/base th the maxim m design a value listed ,i Official, p f i b. Fastener � d�ennined by the Building minimum hould the fastener Value in bellleess than that required, , ildin tl, a revised Should the fa ins, prepared, g signed and wed by a Florida Registered) Engineer; the withdrawal a Registered fa Roofr spading, Consultant mpyrbe, Said revised fastener spacing Hance with be submntted. TAS 105 and calculations in cocup or r e istanred is ue aen r m may Application Standards resistance value taken from Testing 117. PP a reguira3ments of t �'�• Roofing Application Standard RAS with the uplift pressure Hance with sheet u calculated in so of these Perimeter and corner shall be increased comply et hee and calculated ed by in Florida registered Fastener Application shalt bdarrdrRASS 117. CCalculations prepared, Consultant sealed limitation is Roof Cons (When thus lipa� Roofing ens Application Stan Registered Architect, or Registered limi Engineer, Reg' General Limitation #9 will not be applicable) shall Professional Ens termination designs All attachment t and sizing within fp teeter Hailers, metal profile, and/or flashing Application Standard RAS 111 and applicable wind load requirements. a zones (i.e. field, �. All at#achrnant and sizing p linable m, all roof pressure with Roofing pP laude shall be ropermitted for enhanced 9. The maximum designed pressure Neither rational a listed shall extrapolation fastening ng a and corners). pressure z rational a eriys , extended eorners fastening at enhanced p }assure zones (i.e. perimeters, General �,pn,ltatlon #7 ill not betapplicable.) limitroi u is specifically }hall real within a this s+sura1 d herein shall have a quality assurance audit in accordance with the Florida Building 10. All products listed and Rule 9B-72 of the ND OF THIAdministrative CCEPT NOA No.: 077 - 1749.09 Expiration Date; 1 � /08 Approval Pate: e 19 of 19 MAW DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Hanson Roof Tile 1340 SW 34th Ave Deerfield Beach, FL 33442 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.aov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code includin: the .' lorida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile LABELING: Each unit shall bear ape _ + e manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 11-1031.03 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 0917.0 Expiration Date: 12/16/ Approval Date: 12/06/12 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Hanson Hacienda Roof Tile, as manufactured by Hanson Roof Tile in Deerfield Beach, Florida and as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, do not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Hanson "Hacienda" Trim Pieces Test Dimensions Specifications Length: 17'W' Width: 13" TAS 112 'h" thick 1= varies TAS 112 w = varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Deerfield Beach, FL. 2.2 EVIDENCE SUBMITTED: Test Anency, Redland Technologies Professional Service Industries, Inc. The Center for Applied Engineering, Inc. MIAMI DADE COUNTY APPROVED Test Identifier 7161 -03 7161 -03 7161 -03 P0402 P0631 -01 Letter Dated Aug. 1, 1994 224 -47099 94 -060B 94 -084 25- 7094 -1 25- 7094 -7 25- 7094 -4 Project No. 307025 Test #MDC -76 Product Description Low profile, interlocking, extruded concrete roof tile equipped with two nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name /Report PA 102 PA 102(A) PA 108 Withdrawal Resistance Testing of screw vs. smooth shank nails PA 108 PA 108 PA 112 PA 101 PA 101 PA 102 PA 102 PA 102 PA 100. Date Dec. 1991 Dec. 1991 Dec. 1991 Sept. 1993 July 1994 Aug. 1994 Sept. 1994 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 Oct. 1994 NOA No.: 12- 0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 2 of 6 2.2 EVIDENCE SUBMITTED: Test Agency Celotex Corporation Testing Services Walker Engineering, Inc. IBA Consultants, Inc. American Test Lab of South Florida Test Identifier 25- 7183 -1 25- 7183 -2 25- 7214 -2 25- 7214 -6 528454 -2 -1 520109 -2 Calculations 2381 -249 RT1024.01- 11 Test Name/Report PA 102 PA 102 PA 102 PA 102 PA 101 Aerodynamic Multiplier TAS 112 TAS 112 Date Feb. 1995 Feb. 1995 March, 1995 March, 1995 Sep. 1998 Dec. 1998 March 1999 09/20/07 10/28/11 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 12- 0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 3 of 6 4. INSTALLATION 4.1 Hanson `Hacienda' Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (i x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Hanson Hacienda Tile 10.0 1.4375 1.08 Table 3. Restoring Moments due to Gravity - Mg (ft -Ib ..#' Tile Profile Table 2: Aerodynamic Multipliers - X (ft3) 4 "• 12" 5 "• 12" Tile 7" 12" greater Battens a, (ft3) Hanson Hacienda Tile Battens irect Deck Profile Direct Deck Batten Application D ct Dec Hanson Hacienda Tile 5.92 6.80 0.267 6.69 0.289 Table 3. Restoring Moments due to Gravity - Mg (ft -Ib ..#' Tile Profile 3 "• 12" 4 "• 12" 5 "• 12" 6 "• 12" 7" 12" greater Battens or Direct Deck Hanson Hacienda Tile Battens irect Deck attens Direct Deck Battens Direct Deck Battens Direct Deck 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Table 4:'ttachment Resistance Expressed as a Moment - Mf (ft -lbf) For Nail -On Systems Tile Profile Fastener Type Direct Deck (Min 15/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Hanson Hacienda Tile 2 -10d Ring Shank Nails 27.8 37.4 28.8 1 -10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2 -10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 43.0 67.5 50.9 i Installation with a 4" tile headlap and fasteners are located a min. of 2W from head of tile. NOA No.: 12- 0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 4 of 6 Table 6: Attachment Resistance Ex esive er nt Mf (ft-fbf) Set Systems Tile Profile °'Tppiication Minimum ;, , . hment sistance Hanson Hacienda Tile Adhesive 26.1 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 11.4 grams. 3MTM 2- Component Foam Roof Tile Adhesive AH -160. Average weight per patty ,8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Hanson Hacienda Tile 3M'M 2- Component Foam Roof Tile Adhesive AH -160 86.614 3M'M 2- Component Foam Roof Tile Adhesive AH -160 45.55 4 Large paddy placement of 54 grams 5 Medium paddy placement of 24 grams Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Hanson Hacienda Tile Mortar Set 20.6 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". Hanson HANSON HACIENDA ROOF TILE TILE IDENTIFICATION MARK (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MANMADE COUNTY APPROVED NOA No.: 12- 0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 5 of 6 FASTENER HOLES PROFILE DRAWINGS HANSON HACIENDA CONCRETE ROOF TILE END OF THIS ACCEPTANCE MIAMI DADE COUNTY APPROVED NOA No.: 12- 0917.07 Expiration Date: 12/16/17 Approval Date: 12/06/12 Page 6 of 6 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AM) CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) 3M Company 3M Center Building 0220- 05 -E -06 St. Paul, MN. 55144 -1000 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miaiui, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.eov /sera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTrr 2- Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MANMADE COUNTY APPROVED NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 try ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofmg Roof tile adhesive Polyurethane SCOPE: This approves 3M''m 2- Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions 3MTM 2- Component Foam N/A Roof Tile Adhesive AH- 160 Foam Dispenser RTF1000 N/A ProPackk 30 & 100 N/A Test Specifications TAS 101 Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property, Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content MIAMIOADE COUNTY APPROVED Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs. /ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94 -060 257818 -1PA 25- 7438 -3 25- 7438 -4 25- 7438 -7 25 -7492 NB- 589 -631 9637 -92 01- 6743 -011 01- 6739- 062b[1] 7050.02.96 -1 528454 -2 -1 528454 -9 -1 528454 -10 -1 520109 -1 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 520109 -2 -1 Test Name/Report TAS 101 TAS 101 SSTD 11 -93 SSTD 11 -93 SSTD 11 -93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 TAS 101 TAS 101 Date 04/08/94 12/.16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93 11/16/94 01/16/95 03/14/96 10/23/98 12/28/98 TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. �F1 F'- 12� MS -W MIAMM:ADE COUNTY APPROVED NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 0540/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -l60 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be.maintained between 1.0 -1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05 /10/12 Page 4 of 7 LABELING: All 3MTm 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY MIAMICADE COUNTY APPROVED Optional 2nds 1) Place enough adhesive to sch for leve 17 to 23 steep Pitch applications equate Inches In contact tills the pan We To 1 In. From outside edge of cover Wit Then instaIl the tile. .0. 2) TUM covers upside down. Plate adhesha 112 Underlayment Nall through plastic cement Rem top portion of the cave course cover On Motto second course of pan thte. EMI= cave end of pad and cover thee am flush at ease line. Ease douse Wee {mortar sham) Phole Fascia Sheathing Optional Pulnt.up Mater am Iongiludinal edges of the NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nag through plastic cement Paddy (between tile) Paddy (under the) in. I x3 in. Single paddy on under. layment Single Paddy under lie Single paddy on top of tile Eave course 2 in. X 71n. medium she paddy eave Fascia course only Nail through plastic cement Nag through plastic cement Underlayment Single paddy under tile Single paddy between the 2 ln. x 7 ht. medium she paddy eave course only 1."").3 x 3 in. Single 41n. paddy an under - layment Single paddy on top of tile Eave Course Fascia Weophola Eave closure Drip edge Single paddy between tile � 1n.x3In. Single Paddy onunderlayment Single paddy on top of tile Eave Course Eave Closure 2In. x 7 in. medium size paddy ease course only END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05 /10/12 Page 7 of 7