Loading...
RF-13-796• Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 189536 Permit Number: RF -4 -13 -796 Scheduled Inspection Date: June 24, 2013 Inspector: Bruhn, Norman Owner: DE LUCA, MOIRA Job Address: 166 NW 96 Street Miami Shores, FL Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number Parcel Number 1131010240190 Phone: 305 - 757 -2612 Building Department Comments RE -ROOF ENTIRE RESIDENCE WITH NEW BORAL SARONY BLAT COLOR THRU AND BUILT UP CAP SHEET ON FLAT Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Urv�✓ �' eve)g /v June 21, 2013 For Inspections please call: (305)762 -4949 Page 11 of 37 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # �� `3' DATE: C INSPECTION AFFIDAVIT .J rns D.Oixnati licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) License #: CeC clu3o� FS 468 Buliding Inspector On- or about -/J I fivt_ ,_. , IAid - :personallyanspectthe too (Date & time) Secondary water barrier work at Ui LIwqc4fm (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large day of Notary Public State of Florida . Sandra Dee Hart My Commission FF 010844 opw Expires 04/21/2017 *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each inspection Revised on 5/21/2009 F•I•E• FLORIDA INTERNATIONAL ENGINEERING &TESTING LAB INSIGHT•INNOVATION •INTEGRATION • Florida International Engineering and Testing Lab LLC 16701 SW 117 Avenue, Miami, FL 33177 Telephone: (305) 378- 1991 -Fax: (305) 378 -1997 Miami -Dade Lab Certification # 07- 0612.11 -State of Florida ca #27273 Owner's Name: Job Address: Roofing Contractor: Permit Number: Approximate Roof Height: ( Type of Access to Roof: ,-.Ladder OtherRequired Testing orce: 35 lbs. Date Installed: 6 /-71,. 1 . , ,,tot � ■ SITE SPECIFIC INFORMATION Type of Tile: "2— feet Slope: N ®1 1- 3 a /: 4 Aeon Approximate Square Footage: et 1 �® ftZ Testing Equipment: .G. 100x Shimpo Instrument Date of Inspection: 11 ,1 TEST RESULTS; P= PASS, F= FAIL Test Location P or F Test Location P or F Test Location P or F Test Location P or F Test Location P or F 1 pia 44 21 Hips & Ridges r, 41 '-'0 61 81 2 I. t 22 42 62 82 3 23 43 63 83 4 24 44 64 84 5 25 45 65 85 6 26 . 46 66 86 7 27 47 67 87 8 28 48 68 88 9 4 29 49 69 89 10 30 50 70 90 11 .31 51 71 91 12 32 52 72 92 13 33 53 73 93 14 34 .6 54 74 94 15 ` 35 ° 55 75 95 16 36 56 76 96 17 37 . 57 -11n 77 97 18 38 58 78 98 19 39 59 79 99 20 ,, 40 60 80 100 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. ADDITIONAL TEST INFORMATION Perimeter Width: A, ft Area Units or ftZ No. of Tests Perimeter • t Field ® 1. Corners 1 p Hips & Ridges 14 940j RESPECTFULLY SUBMITTED BY: \ Vinayagar M. Balakrishnan V 6/20A j State of Florida Lic # 63107 aiSMISNI 111111111111111111111111111111111111111111111111111111111111,1111111111111 101111111 #S'SUO *MIRilI amaninsumaannamounatimusaisamanumanalana 1111111111111111111111X1111 111 11 OMnamannam 11111iii111iiii11iiiiii1iii1'i>1ii #iii11#ii iiiii1ii1a1 is 11 11111 € r r- E U 1 `121111'11 iiii1iiiiii ii11 i� i ? IR 1iiaiiiiiiiiii i C 41r01 11111111/1111111M11111111111111 -hill MIII ,,4111111111111111111111111IMINIIIM 11111111M111111k AMES *amiffaIssusiseanna maimmaassaimatt, ri# : giii11111111111111111111111111111111111111111 Z i � '.#_ E41111 BUISIBUIRMI11111111 #iifiiii��lii '41 tiS,, 11'#1111`.: I,tz`1a 111II *:1111111111 111111111111111111111W; .11iiil1,11111i1i111i 1111111111111111111.111111111t1SMISIBUILitit 111111111111111111111 si #iiiiii`r7AZUMMTN Iniv,i'iilialt111iii11 iiiii 'iiiiil1lli1111 r ntra au 11191 -- -, I i i iiiiiiiii 11111. 111111111#1i1111111111111;11111111111 11111111111115 111 111111.111 x11111111:,:" W.. - �r 1k' si aiima I a sausamisaaasimanassaananintamananuniunii 1s' R : 1111 *i..'i,1;1a11171:111.i11i11 1111111 111111111111111 1111111111 11111 11111111 NOTICE OF COMMENCEMENT C FN 203-;. 3.3R.033004 4 Cl�. eI; �'�Sx.S:3j, t`9 4173 t (iPl A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION R:E COR'D,ED X04 ; 26. •2013 1111445 HARVEY RUVI t r CLERK OF COURT PERMIT NO. TAX FOLIO NO. / b% 46 LMAT `I - •A DAaE DS COMITY FLORIDA STATE OF FLORIDA. COUNTY OF MIAMI -DADE: STATE OF F.OR„A, COUNTY OF LADE HEREBY CERTIFY kthe �rais oopy Ma - cr.11 s tom,` in this THE UNDERSIGNED hereby gives notice that improvements will be made to property, and in accordance with Chapter 713, Florida Statutes, the fcoi is provided in this Notice of Commencement. HARVEY- iv. -- - 1. Legal description of property and street / address: l , p 2. Description of im Li(4siwtt g/ re ement: 1{ `� e4.-6( 5 r 4-r ,'Le t /Ott. J 4Lc L cr 3. Owner(s) name andaddress: i . �, '4.aI Lac 741.E —V SI1b1^G, r 31.3 Interest in property: Name and address of fee simple titleholder: 4. Contract 6s name and address. f. 5" 1J �a -5°C —t c.\ 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: 9. Expiration da this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different dais sspecifie • ) / / pyfit Owne Name_ g attar of OwrerE Prepared by 201)) Sworn to and subsaribed before me this 1 Notary Public. t j Print Notary's ame: My commission expires: Address: 1-144A-1) c5-- 71 tK - "-) Miani Shores Village Building Department /0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: JOB ADDRESS: Permit No. APR 17 2011 FBC 20 Master Permit No. BUILDING OOFING City: Miami Shores / Coouity: Miami Dade Folio/Parcel #: // 3 ` ) ! 0°Z V 6 l ` Is the Building Historically Designated: Yes NO 1/ Zip: 33 l Flood Zone: OWNER: Name (Fep Simple Titleholder): 11-10( ft �- U� Phone #: Address: /61 Li L r `I 6 5 City: Lf /AI.tl Shbre State: Zip: 3 31 3b' Tenant/Lessee Name: Phone #: Email: e t Roo-r er CONTRACTOR: Company Name: Address: Phone#: 3 °3— 26-17°- Zip: 33' 3d' City: Ali "9/t-e) Eh 9 State: Qualifier Name: "-C e.) State Certification Registration tact 6 b %2 -Email Address: DESIGNER: Architect/Engineer: Phone #: p n or Re 'stration ! T' Certificate of Competency #• 19 »1 /) ,h6 `'(rcf cab r� 0,.,- Contact Phone #: Value of Work for this Permit: $ LLr `� 2 7 dAltera n p G r D Q'4- e-p - r r 1� 4 e. Type of Work: ❑Addi Description of Work: Phone#: /902 Square/Linear Footage of Work: ❑New 'Repair/Replace UDemolition &) 1 # p1 CtAi —be) r (Ca oh ti 4 Cam- e--e/ 6/t_ 4u d 'h i r, iPt Color thru tile: 74c R� Sato r1.1 .e, t � � d x" ********* * * * * * *** * *x** ** *xxx**** * *** * *Feesx** *** sx * *xx**** * ** * * *** * *******4 -Kk O f / Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ 2(.o1 ?=' Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State, Zip Application is hereby made to obtain a pe "t to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a • - rmit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In t e absence of such posted notice, the inspection will not be rove'' and a r' ' spection fee will be charged. Signature ,. . r or Agent Contractor The forelgaling ins nt was acknowledged before me this 1 The for /, ang instrument was acknowledged before me this if‘' o ; �� , , 2011 , by , day of ifteai , 20 / 3 , bytes "��5 27 ® /e�40,1-- wl.,..p..i.s.person111Ffi.Own to me or who has produced who i = rsonally kno .�' o me or who has produced as identification and who did take an oath. NOTARY PUBLIC: As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires N >q a:4fl 5IIn1m.ica ***************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Sign: Print: My Commission Expir JOHN M MACO otary Public - Stale of Florida 10, 2016 Commission # EE 833887 " os F� Bonded through Fiona •,,,�� ». Notary Ain APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised 3 /12/2012)(Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: 'LC,/ 6 f (2-6_ 1 s E i, 1.'C - Property Address: /(.0 4 A) 1 t St kt t i4 �/ O AO tt) Roofing Permit Number: 3 1 3 Dear Building Official: I b r (Let certify that I am not required to retrofit the roof to wall connections of my building because: 1 aThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad lorem taxation. ❑ The building was c• tructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions Dater f f f' of 1994 edition% e.South Florida Building Code (1994 SFBC) )4-10 IP A- Z., cif., Print Name State of Florida County of Dade The undersigned, being the first duly sworn, depos s and says that he/she is the owner for the above property mentioned. 1 Sworn to and subscribed before me this day of Notary Public, Sate of Florida at Larg When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 Page 2 of 2 earah Enter either folio, owner name, or address. Selected Property Information Property Information Full Legal Description Assessment Information Exemption Information Sales Infomlation Ad dltlo n al Information Featured Online Tools Tax Comparison Tax Estimator TRIM Notice CO View Taxes Additional Online Tools Back to Results Assessment Information Year: Land Value: Building Value: Market Value: Assessed Value: 2012 5:56,744 577.788 5144.532 5144.532 2011 574,1510 577.788 5151.948 5151.948 Taxable Value Information Exerip:iotl ;Taxab:e Exemption !Taxable Value Value County: 55:;.0.!) 594.532 $50,000 /5101,948 School Board: $25,` 00,5119,582 $25,0004126,948 City: $5r t :ln '594.532 550.000;$101,948 Regional: $5',) 000 ;554.532 550.000 13101.948 Street Map I . ,eriol Map i. -ST 'a at ra PrIN,317y n10ac Ie CKP.r?1 ',r. dat, ;:nd �fleac w'ri:' ade u�ry t.t;rn-v� SWit, :fry fe 7'.'0 33 Hume a up lido:Ai- 30, http://gisweb.miamidade.gov/PropertySearch/ ^c'* 't!3n3 .:.1. :!'5 wmta:'[if.3, i t3 t∎ruro ,G- 1f.Ryt 1r !alt yr ❑^I, Ctrf2 t.rint•O .,, ir:videt .g.a 1.., 10/4/2012 Owner's Notification Form HVHZ 2010 L "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofmg permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. >2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring um "s (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofmg contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roe fmg system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the inter or of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, desi ed by a Florida- licensed engineer or registered architect to eliminate the attic venting, venting shall not b j e _ed. Owner's /Agent's Signature: Contractor's Signature: Property Address: /4 G &.J ' ..5,r Date: / / L21 Permit Number: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH - VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C • 1,2,3,4,5,6,7 Prescriptive BUR -RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable. Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation 2010 FLORIDA BUILDING CODE — BUILDING 15.33 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Master Permit No. Contractor's Nam Job Address NIX Low Sio ❑ Asphaltic ❑ New Roof Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) 13- -`aka, Low Slope Roof Area (SF) Xeoq INFORMATION Steep Slo ed Roof Area (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Total (SF) / - 15.34 2010 FLORIDA BUILDING CODE — BUILDING Process No. k.) 166 A-16-4-) q'IL_ r Shingles = Reroofing ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ ❑ Metal Panel/Shingles ❑ ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ Recovering ❑ Repair ROOF SYSTEM Mortar Wood /Adlisivg.Set Shiti r nom Ir ,,j® 0 ci o • SUBJECT (0 CCMPUUMCE WITH ALL F STATE AN CCUtst f AUL S AND REG( ho esiSlake T 0 ® Mai < ZANG DEPT BLDG DEPT Low Slope Roof Area (SF) Xeoq INFORMATION Steep Slo ed Roof Area (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Total (SF) / - 15.34 2010 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Unfform Permit Application Form. Section C (Low Slope Application) FIII in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer: 01-F Product Approval No.: 6 9 ----/01 i 4 • to Design Wind Pressures, From RAS 128 or Calculations: P1: - C' P2: -%1. 7 P3: /0 /•ci Max. Design Pressure, from the specific Product Approval system: Deck: Type: 52 Gauge/Thickness: Slope: l fa t St. Anchor /Base Sheet & No. of PIy(s): A/ et Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: AJ,/J Base Insulation Size and Thickness: Base Insulation Fastener /Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): &Weds ' 2( Bas Sheet astener/Bo in Material: Ply Sheet(s) & No. of Ply(s):.2 - . /Iic 2 t,7 Ply Sheet as er/Bgfn g Arya" Top Ply: �AF -!(6e/ 9' 11 5' CA f? ALT Top Ply Fastener /Bondi TYP e toll g Mate ial: Ayitift 2010 FLORIDA BUILDING CODE — BUILDING Surfacing: /.F, 4 Fastener Spacing for Anchor/Base Sheet Attachment: Field: 9 " oc @ Lap, # Rows Z @ r " oc Perimeter: 0 " oc @ Lap, # Rows 1{ " oc Corner: G " oc @ Lap, # Rows 5- @ "oc Number of Fasteners Per Insulation Board: Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener_Type, Fastener Spacing or Submit Manufactur- ers Details that Comply with RAS 111 and Chapter 16 /Or WrAfrlifiv e410. FI:PierAwp 77, ?J- rvc 4o Parapet Height Mean Roof fa Height 15.35 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: -oti Notice of Acceptance Number: /2-0 2 22 r 3 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations 1: if d / P2: / 3. '3 P3: "23' Y 1 1 Roof Slope: : 12 Steep Sloped Roof System Description \ Deck Type: ` Type Underlayment: Ridge Ve ilation? A)A- Insulation: .• m 2,22 G \ Fire Barrier: Adr Fastener Type & Spacing: Adhesive Type: Type Cap Sheet: ti Mean Roof Height: L_ "Alm .S_. Roof Covering: Type & Size Drip Edge: 2G 94- fQlv- 15.36 2010 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High - Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mr values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based The Calculations Per RAS 127" (P1:311-1 ppFf x 7. i,3rl = 44)1)- Mg: 8.t7 / =Mr, 4 d2( Product Approval Mf (P2: 144 x?� j/I� . 13�)- Mg :e/CO = M /3 °�� // Product Approval Mf `• 7' (P3: ( ®O � � x � 3 / 3 4 / �) - Mg:®.0 3 = Mr32 ' V' Product Approval Mf Y1./ ' Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval M Mr required Moment Resistance* Mean Roof Height -+ Roof Slope ,,, 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3 :12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based The Calculations Per RAS 127" (P1: xL xw: =_) -W: x cos 0 =Fri (P,: x = xw := ) - W: x cos0 =Fr2 (P3: x L = x w: = ) - W: x cos 0 = Fr3 Product Approval F' Product Approval F' Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based onASCE7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier 1 Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 2010 FLORIDA BUILDING CODE - BUILDING 15.37 DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.eov /oera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA #07- 0711.03 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: Deck Type: Roofing Roofing Tiles Concrete Wood 1. SCOPE This NOA approves a system using Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Applicant Saxony 900 Trim Pieces Dimensions 1 =17" w = 13" 1- 5/32" thick Slate 1- 9/32" thick Shake & Split Shake Length: varies Width: varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL. 2.2 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. MaAM I.DADE COUNTY APPROVED Test Specifications TAS 112 TAS -112 Test Identifier 7161 -03 Appendix III 94 -084 94 -060A Product Description Flat profile, interlocking, high - pressure extruded concrete roof tile equipped with two nail holes. For direct deck or battened nail -on, mortar set or adhesive set applications. Accessory trim, boosted Barcelona, concrete roof pieces for use at hips, rakes, ridges and valley terminations manufactured for each tile profile. Test Name/Report Date Static Uplift Testing TAS 102 & TAS 102(A) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 101 (Adhesive Set) Dec. 1991 May 1994 March, 1994 NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 2 of 8 The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. MIAMI•DADE COUNTY APPROVED 25- 7183 -6 25- 7183 -5 25- 7214 -1 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 P0402 Project No. 307025 Test #MDC -77 R1.894 R2.894 R3.894 520109 -1 520111 -4 520191 -1 Evaluation Calculations Evaluation Calculations Evaluation Calculations Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain TAS 100 Physical Properties TAS 112 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 3 of 8 Walker Engineering, Inc. Evaluation 25 -7183 Calculations Walker Engineering, Inc. Evaluation Aerodynamic Multipliers Calculations Walker Engineering, Inc. Calculations Two Patty Adhesive Set System Walker Engineering, Inc. Evaluation Restoring Moments Due to Calculations Gravity Nutting Engineers 130 TAS 112 March 1995 January 2007 April 1999 February 2007 January 2007 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Saxony 900 Slate, Shake & Split Shake 11.5 1.417 1.08 MIAMI•DADE COUNTY APPROVED NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 4 of 8 Table 2: Aerodynamic Multipliers - X (ft3) Tile X (ft3) A. (ft3) Profile Batten Application Direct Deck Application MonierLifetile Saxony 900 0.289 0.313 Slate, Shake & Split Shake MIAMI•DADE COUNTY APPROVED NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 4 of 8 Table 3: Restoring Moments due to Gravity - Mg (ft -Ibf) Tile Profile 2 ":12" 3 ":12" 4 ":12" 6 ":12" 6 ":12" 7 ":12" or greater Saxony 900 Slate, Shake & Split Shake Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.16 8.12 7.08 8.03 6.97 7.91 6.82 7.74 6.65 7.55 6.46 7.34 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Saxony 900 Slate, Shake & Split Shake 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Adhesive 31.32 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 5 of 8 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Polyfoam PolyProm' 118.9' Polyfoam PolyProTM 40.44 3 Large paddy placement of 45 grams of PolyProT"'. 4 Medium paddy placement of 24 grams of PolyPro TM. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft -Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance MonierLifetile Saxony 900 Slate, Shake & Split Shake Mortar Set' 43.9b 5. Tile -Tite Roof Tile Mortar 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved ". LABEL FOR SAXONY 900 TILE (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 6 of 8 NAIL HOLES PROFILE DRAWING 1 5/32 " (slate) 1 9/32 " (shake) 17" WATER LOCK 13" SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL) OVERLAY MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SPLIT SHAKE MODEL) MANMADE COUNTY APPROVED NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 7 of 8 MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SHAKE MODEL) END OF THIS ACCEPTANCE MAMNDADE COUNTY APPROVED NOA No.: 12- 0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 8 of 8 PIIAM DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) 3M Company 3M Center Building 0220- 05 -E -06 St. Paul, MN. 55144-1000 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.aov /pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2- Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 11- 0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves 3MTM 2- Component Foam Roof Tile Adhesive A11-160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2- Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2- Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH- 160 Foam Dispenser RTF1000 ProPack® 30 & 100 N/A Dispensing Equipment N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2- Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property, Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs. /ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 2 of 7 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94 -060 257818 -1PA 25- 7438 -3 25- 7438 -4 25- 7438 -7 25 -7492 NB- 589 -631 9637 -92 01- 6743 -011 01- 6739- 062b[1] 7050.02.96 -1 528454 -2 -1 528454 -9 -1 528454 -10 -1 520109 -1 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 520109 -2 -1 Test Name/Report TAS 101 TAS 101 SSTD 11 -93 SSTD 11 -93 SSTD 11 -93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 TAS 101 TAS 101 Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93 11/16/94 01/16/95 03/14/96 10/23/98 12/28/98 TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F 2j F'— MS —W NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 3 of 7 INSTALLATION: 1. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that Lists uplift resistance values with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2- Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2- Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 4 of 7 LABELING: All 3MTm 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nall through plastic cement Paddy (Beneath Tile) Underlayment 1 10 in. Ens Course Eave Closure Fascia Eave course only: Keep adhesive approx. 41n. up from weepholes Nall through plastic cement N14111ftt,t—: 1%1 • aveoume Underlayment Paddy (Beneath Tile) 1%0 in. 2 In Eave course only: Keep adhesive approx. 4In. up from weepholes Fascia Weephole Eave closure Drip edge 1) Place enough adhesive to achieve 17 to 23 steep pitch applications square inches in contact with the pan tile 2) Tum covers upside down. Place adhesive 1!21n. To 1 in. From outside edge of cover tile. Then Install the tile. Optional 2x4's for Underlayment Nall through plastic cement Remov top portion of the eave course cover Mc Abut to second course of pan tiles. Ensure eave end d pan and cover tiles are flush at eave Ilne. Eave closure (mortar shovm) Weephole Fascia Mienthing Optional Point-up Mortar on longitudinal edges of Me NOA No.: 12-0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 5 of 7 Nall through plastic cement ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Paddy (Beneath Tile) Nall through plastic cement Paddy (Beneath Tile) Underlayment Eave Closure Eave Course Fascia NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy (between tile) Paddy (under tile) I x 3 In. Single paddy on under- layment Single paddy under tile Eave course Single paddy on top of tile 2 In. X 7 In. medium size paddy eave Fascia course only Nail through plastic cement Nail through plastic cement Underlayment Single p addy under tile Single paddy between tile 2 In. x 7 In. medium size paddy eave course only in. x 3 in. Single 41n. paddy on under- layment Single paddy on top of tile Eave Course Single paddy between tile in.x 3 in. Single paddy on underlayment Single paddy on top of tile Eave Course Eave Closure 2 in. x 7 In. medium size paddy eave course only Fascia END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED Fascia Weephole Eave closure Drip edge NOA No.: 12- 0228.18 Expiration Date: 05/10/17 Approval Date: 05/10/12 Page 7 of 7 M I�A M ICA[}E BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation. 1361 Alps Road Wayne, NJ 07470 MIAMI -DADS COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ), This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA, Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 throygh 19. The submitted documentation was reviewed by Jorge L. Acebo. () NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 1 of 19 Deck Type 1: Deck Description: Wood, Non - insulated • 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: (optional) FireOutTM Fire Barrier Coating, VersaShield ®Non - Asphaltic Fiberglass -Based Underlayment or SecurockTM. Base sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT+:? EliminatorTM Nailable, RUBERO1D® Modified Base Sheet, RUBEROID® 20, RUBEROID® Heat- We1dTM Smooth or RUBEROID® Heat- We1dTM 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® -Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-Teem #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -•4S psf, See General Limitation #7) GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure S2.5 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved 1A" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Dri11 -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure --60 psf, See General Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 17 of 19 Ply Sheet: Cap Sheet: Surfacing: Maximum Design Pressure: See Fastening Above GAFGLASs' #75 Base Sheet or any of above Base sheets attached to deck with Drill -Teem #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 ps, f; See General Limitation #7) One or more plies of GAFGLAS® PLY 4, #80 ULTIMA, RUBEROID® MOP Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbssq. (Optional, required if RUBERO1D4) MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbsisq. respectively in a flood coat of approved asphalt at 60 lbsisq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gaL /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLASa Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbsisq. 3 Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT' MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote+li roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at ito 1.5 gal.isq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 18 of 19 • e WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex PIyTM 6 when used as a mechanically fastened base or anchor sheet, 2. Minimum Y4" Dens DeckTM or V2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL, LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. • 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 Ibs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall .be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 Ibs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 paf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 1b£ insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor /base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and /or flashing termination designs shall conform with Roofmg Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (Le. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE • MIAMLDADE COUNTY APPROVED NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03 /20/08 Page 19 of 19 4 2007 ROOFING MATERIALS ANOSYSTEIVIS'DIRECTORY 192 ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFIJ)—Continued Base Coat "A-38 Series", 0.75 gal/sq. Second Base Coat "A-38 Series", 0.75 gal/sq. Wear Coat " A-38 Series ", 0.75 gal/sq plus walnut shells at 0.75 lbs per Surfacing: " A-38 Series ".0.75 gal/sq plus walnut shells at 075 Ibs per sq. sq. 46 Deck: NC Incline: 3/4 Foam: Spray application of 2-in. thick "Polyfoam 273" (2.7 lb / ft.3 ) Surfacing: Spray application of 28 to 34-mils "U-8730" (aluminum) 47 Deck: NC bidine: 1/2 Insulation: Spray- `apPit' cation of 2-in. thick "Polyfoam 273" (2.7 lb/ft.3 ) Surfacing: Spray application of 28 to 34-mils "U-8782" (ivory) GAF, ,1114TRIALS CORI) R1306 1361 ALPS RD, WAYNE NJ 07470 "Ruberoid 20" or "Ruberoid Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G-P Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Also, multiple plies of "GAFGLAS Ply 4" or "Ply 6" may be adhered to G-P Gypsuxi DensDeck® in hot asphalt. nergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification. "GAF Stratavent Eliminator Venting Base Sheet (Nailable)" may be mechani- cally attached or hot mopped over noncombustible decks and as a recover over existing roof systems. GAFGLAS Perlite Insulation may be utilized as a cover board over "EVER- GUARD" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane insulation adhesive. Polysty- rene reference in any of the following Classficatons include "ENERGuard EPS Insulation". References to glass fiber insulation include "EnergyGuard Fiberglass Insu- lation". Type G2 asphalt ass mat base sheet ("GAFGLAS #75 Base Sheet" or ASPHALT SYSTEMS wrni HOT ROOFING ASPHALT "GAFGLAS #80 UL A" ) is a suitable alternate for Type Gi asphalt glass fiber ply sheet ("GAFGLAS Ply 4" or "GAFGLAS Ply 6" ) in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAF Stratavent Eliminator Venting Base Sheet (Perforated)" or "GAF Stratavent Eliminator Venting Base Sheet (Nailable)" . Perforated to be mopped and nailable to be mechanically attached granule side down. As an,optinn Type, G2 asphalt glass mat base sheet ("GAFGLAS #75 Base Sheet", "GAFGLAS #80 ULTIMA" or "GAF Stratavent Eliminator Venting Base Sheet (Nailable)" may be substituted for G1 asphalt glass fiber ply sheet ("GAFGLAS Ply 4" ,or "GAFGLAS Ply 6") as the nailed base ply in the following systems. Bottom ply base sheet may be solid mopped, spot mopped or mechani- cally fastened. Unless otherwise indicated, all insulations may be hot mopped or mechani- cally fastened. "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE®" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C-15/32 decks. The use „of, polystyrene insulation board between min 3/4 in. perlite board and deck with rosin paper (perlite /rosin paper/polystyrene/perlite) is a suitable alternate for isocyanurate board in the following Class A, 13 or C systems. "BMCA EnergyGuard RA", "BMCA Tapered EnergyGuard RA" and "BMCA EnergyGuard RA" may be substituted for any Atlas polyisocyanurate insula- tion m any of the following Classifications. Trumbull "Perind Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". GAFGLAS #80 Premium Base Sheet may be used in any of the following systems. "GAFGLAS Flex Ply 6" is a suitable alternate to "GAFGLAS Ply 6". ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)—COntinued "GAYTEMP Permalite Recover Board" may be used in lieu at any, insulation in any of the following.NC'Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems x Roofing Asphalt" may be surfaced with "Fireshield MB" at 2.5 — 3.04 Class A, 13 and C Hot roofing asphalt, for use with organic and glass felts or madifieefl membranes. "Ruberoid Heat Weld" SBS roofing, membrane may be used "Ruberoid Mop" SBS products in any applicable Classification. Class A 1. Deck: C-15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fit fiber, isocyanurate, urethane, perlite/isocyanurate composite, urethane composite, wood fiber/isocyanurate composite, pher thickness. Ply Sheet Three or more layers Type G1 "GAFGLAS P "GAFGLAS Ply 6", hot mopped. Surfacing: Gravel, Deck: C-15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fl fiber, isocyanurate, urethane, perlite/isocyanurate composite urethane composite, wood fiber/isocyanurate composite, phe thickness. Ply Sheet', Three or more layers Type G1 "GAFGLAS "GAFGLAS Ply 6". Cap Sheet One layer Type G3 "GAFGLAS Mineral Suri Sheet" or "EnergyCap Mineral Surfaced Cap Sheet". Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood 1 fiber, isocyanurate, uretliane, perlite/isocyanurate composit urethane composite, wood fiber/isocyanurate composite, phe max. : Ply Sheet Tiyo or more layers Type GI "GAFGLAS Ply 4" GLAS Ply 6". ' Cap Sheet One layer Type G3 "GAFGLAS Mineral Sul Sheet" or "EnergyCap Mineral Surfaced Cap Sheet". 4. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R", 4 in. max, hot Ply Sheet Any UL Classified gravel surfaced Class A asphal mat system. 5. Deck: C-15/32 Incline: I Slip Sheet (Optional): Red rosin paper, nailed to deck. Base One layer Type G2 "GAFGLAS #75 Base She n e Ply Sheet One or more layers Type G1 "GAFGLAS Ply 4" or Ply 6". Cap Sheet One layer Type G3 "GAFGLAS Mineral Su Sheet" or "EnergyCap Mineral Surfaced Cap Sheet". Deck: NC Incline: 3 Base Sheet One layer Type G2 "GAFGLAS #75 Base Shee Ply Sheet One or more layers Type G1 "GAFGLAS Ply GLAS Ply 6". Cap Sheet One layer Type G3 "GAFGLAS Mineral Si Sheet" or "EnergyCap Mineral Surfaced Cap Sheet". . Deck: C-15/32 Incline 2 Insulation: One or more layers perlite, glass fiber, isocyr thane, perlite/isocyanurate composite, perlite/urethane con nolic, 1.0 in. min (offset from plyvrood joints 6 in.). Base Sheet: One or more layers Type Gl, G2 or G3,,r-- Membrane: One or more layers "Ruberoid Torch" (Smooth "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (Smoott or "Ruberoid Mop Plus" (granule). Cap Sheet: Type G3 "GAFGLAS Mineral Surfaced Cr "EnergyCap Mineral Surfaced Cap Sheet", hot mopped. - : 8. Deck: C-15/32 Incline 2 Insulation (Optional): One or more layers perlite, woo fiber, isocyanurate, urethane, perlite/isocyanurate compc urethane composite, wood fiber/isocyanurate composite, I thickness. Base Sheet: Two or more layers Type G2 or G3. Ply Sheet (Optional): One or more layers Type G1. Membrane:: ,One or more ,layers "Ruberoid Torch" (Smoot] "Ruberoid Tomb. Plus'Afgranule), "Ruberoid Mop" (Smoot or "Ruberoict Mop lhirs"..(granule). 2. LOOK FORTHE UL MARK CIOROppOr