Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-13-922
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 190439 Permit Number: MC -5 -13 -922 Scheduled Inspection Date: May 20, 2013 Inspector: Perez, JanPierre Owner: ROMANIK, DAVID Job Address: 95 NE 95 Street Miami Shores, FL 33138- Project: <NONE> Contractor: CLASSIC AIR INC Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132060130730 Phone: 305 - 825 -2486 Building Department Comments REPLACE OF ONE FIVE TON SPLIT SYSTEM Infractlo Passed Comments INSPECTOR COMMENTS False 51 Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. May 17, 2013 For Inspections please call: (305)762 -4949 Page 9 of 27 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 190439 Permit Number: MC -5 -13 -922 Scheduled Inspection Date: May 20, 2013 Inspector: Perez, JanPierre Owner: ROMANIK, DAVID Job Address: 95 NE 95 Street Miami Shores, FL 33138- Project: <NONE> Contractor: CLASSIC AIR INC Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132060130730 Phone: 305 -825 -2486 Building Department Comments REPLACE OF ONE FIVE TON SPLIT SYSTEM Infractio Passed Comments INSPECTOR COMMENTS False 5/ 26 ( Inspector Comments Passed IE)( Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. May 17, 2013 For Inspections please call: (305)762 -4949 Page 9 of 27 Miami Shores Village Building Department 40050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: MECHANICAL QQ JOB ADDRESS: "J S NE cis 5 T FBC 20 t Permit No. Master Permit No. I n c 3 "' I 2z- City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel #: 11 ^ 32.0(9- 013-013o Is the Building Historically Designated: Yes NO ✓ Flood Zone: OWNER: Name (Fee Simple Titleholder): 6 R V ! t 2 0 M IA?JI k Phone #: Address: .S k) 6 9 ST. City: 1.'41$ M 5 H ORES state: 11. , Zip: 33138 Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company Name: C L A s 51 C. 1 i {L. 111.-/ C. Phone #: 30 S g 2 s -248f• Address: 1 g 0 1 IA) e s 1 2.S C T• City: Pli A 1 Q 0.1'1 State: r. L. Qualifier Name: 1E rt.rtm L. (C 5S Phone #: 36 S 82.S -2.48 (. State Certification or Registration #: Certificate of Competency #: Contact Phone #: -30'S $ 2. � - 2. S g' Email Address: P i> Ct Si I v A O C Ls SS 1 C Pr 12-' I. Gall DESIGNER: Architect/Engineer: Phone #: Zip: 3 3 o 1 �o C Value of Work for this Permit: $ � Square/Linear Footage of Work: Type of Work: UAddress OAlteration ONew ZfRepair'` eplace ODemolition Description of Work: Re f LA GG ) -vaa -) + o� 0w1 E. Ave. A -Iro s L s�{S +e1-1 L14144% owe 10 K vJ ee Submittal Fee $32 pA' ' Permit Fee $ ce� Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ V �CF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE 419 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDTTIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of ? 20 f ?, by t v) gjlcANc9-Ai i k , day of Li - 2 t- ( , 20 %, byTE-9 py L Res wllo fi personally kno to me or who has produced ersonally kno me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Ex as identification and who did take an oath. NOTARY PUBLIC: RES: Watch 23,'2Y ( Pettc tilZe.rvilers ***************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** APPROVED BY Plans Examiner Zoning Structural Review Clerk Revised 3 /12/2012)(Revised 07110 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work Is being done): 95- OE '' S S' i , City: Miami Shores Village County: Miami Dade Zip Code: 3 3 l g ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AR! (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO ❑ ARHI Sheet Attached: YES NO ❑ Contract Attached: YES 0 UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER " (r ) t K AHU or PKG. UNIT MODEL # 414XWblifPj2, X e-.°$ F f� O S c{ 1 COND. UNIT MODEL # KW HEAT r i 0 NOM TONS 5- AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG , 2) M.O.P AHU CU PKG _ AHU CU PKG , 3) VOLTS log 12 30 ' AHU e'd.UJ PKG PKG UNIT / / PKG UNIT / / EERISEER 15 , 5— YES NO REPLACING DUCTS YES YES NO REPLACING THERMOSTAT YES YES NO NEW 4 °CONCRETE SLAB YES; YES NO NEW ROOF STAND YES • YES NO NEW RETURN PLENUM BOX YES ( NO 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker Size): Ps) L L - v 'pip 5-4 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: 5 A=4-%-c ®► �o�a,� # Contractor's Company Name: C LA 55 r C d C. Phone: .3 0- S" 2 g State Certificate or Registration N. Certificate of Competency N. Signature all Per's signature only) Date: `I ig6 i 3 7801 West 25th Court Hialeah, Florida 33016 eLM /%Z4 . Mechanical Contractors CACO21300 Dade 305 - 825 -2486 Broward 954 - 522 -2486 Fla Wats 800 - 246 -2486 Fax 305 - 825 -0794 David Romanik 04/23/2013 95 NE 95 Street Replace Condensing Unit Miami Shores, Fl Replace Evaporator Unit Proposal # 13309 We Propose hereby to furnish the following: 1) Reclaim refrigerant as per EPA regulations. 2) Disconnect and remove existing five ton Carrier condensing unit and air handler. 3) Set new five ton (YCJF60S4151 EA) York condensing unit in place. 4) Install replacement (AHX61 D4P121) air handler. 5) Reconnect existing refrigerant piping and electrical service to new condensing unit. 6) Install refrigerant dehydrator. 7) Evacuate and leak test system. 8) Start up and check system for proper operation. 9) Return system to normal cooling mode. INCLUDES: All materials, labor, sales tax and permit fees. LIMITED WARRANTY: Manufactures 10 (TEN) year limited warranty on parts. Manufactures 10 (TEN) year limited warranty on compressor. TOTAL COST $4,574.00 This Proposal May Be Withdrawn by Us If Not Accepted Within 30 Days. Terms and Conditions of this Contract: It is expressly understood and agreed that title to the above described property is retained by Classic Air, Inc. and same shall not pass or become vested in the purchaser until the entire purchase price has been paid. Said property shall be and remain personal property and retain its character as such and purchaser shall not attach or affix said property to any realty so that it loses its character as personal property nor shall purchaser resell said property until the full purchase price therefor has been paid. The purchase price shall be due and payable as provided under "terms" above, and upon the failure of the purchaser to make any payments on the due date the seller, at its option, may declare the entire balance of the purchase price due and payable, in case of default, purchaser shall pay all costs and damages, including a reasonable attorney's fee incurred by seller in collecting this account or repossessing the described property, whether suit be brought or not. Purchaser hereby waives presentments, demand, and all other pre - requisites required to make it liable. No warranties, representations, or promises, not appearing in writing in this contract will be recognized. This agreement shall not be considered executed or binding to the seller until duly accepted by an authorized officer of the seller. The execution by seller of this agreement is subject to force majeure and is contingent upon strikes, accidents, acts of God, weather conditions, regulations, or other restrictions imposed by any Government or Governmental agency or other delays beyond sellers control. For Classic Air, Inc.: Date: Accepted By: For: Date: Certificate of Product Ratings AHRI Certified Reference Number: 4357491 Date: 4/22/2013 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: YCJF60S41S1 Manufacturer: YORK BY JOHNSON CONTROLS Indoor Unit Model Number: AHX61 Manufacturer: YORK, UNITARY PRODUCTS GROUP Trade /Brand name; YORK, COLEMAN, LUXAIRE, FRASER - JOHNSTON, STYLE CREST, DAYTON, EVCON, GUARDIANAIRE Manufacturer responsible for the rating of this system combination is YORK, UNITARY PRODUCTS GROUP Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 58500 EER Rating (Cooling): 12.55 SEER Rating (Cooling): 15.50 * Ratings followed by an asterisk (•) Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified atwww.ahrldirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which 1s listed above, and the Cer Mcate No., which is listed below. 02013 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130111168119109204 ®M ®®Air- Conditioning, Heating, and Refrigeration Institute MG 1-grz.2__ '043650-1 BUSINESS NAME CASSC ANC 7801 W 25 CT 33016 HIALEAH FIRST -CLASS U.S POSTAGE PAID MIAMI, FL PERMIT NO. 231 THIS IS NOT A BILL — DO NOT PAY RENEWAL RECEIPT NO. 043650-1 STATE* CACO21300 OWNER CLASSIC AIR INC Sec. Type of Business 196 SPEC MECHANICAL CONTRACTOR THIS IS ONLY A LOCAL t BUSINESS TAX RECEIPT. IT DOES NOT PERMIT THE • HOLDER TO VIOLATE ANY EXISTING REGULATORY OR : ZONING LAWS OP THE ' COUNTY OR CITIES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS IS NOT A CERTIFICATION OF THE HOLDER'S QUALIFICA• T1ONS. PAYMENT RECEIVED MIAMI -DADS COUNTY TAX COLLECTOR: .07/26/2012 60090000083 000045.00 SEE OTHER 4113E WORKER /S 10 DO NOT FORWARD CLASSIC AIR INC 7801 W 25 CT HIALEAH FL 33016 4dh. idiot! illlflfluhll1ii113d1lfilfltli} A,14$J ASV DOCUMEN r LOR GROUNpa =:INICROPRINTING • L'JNEMA. PATENTED PiA�El ;ya a Ke' STT FLORIDA PAR' ENT `BUS HE SAND PROFESSIONAL REGULATION CONS UCTION INDUSTRY `;L ENSING BOARD LI CENSII NB 1181908 1 ACO2.3' 'he CLASS A AIR CONDIT'!I ONT. NG Named elow CERTIFIED 'Under' the <:p ;ovisio s a Chapt' Expiration date.: ''AUG 31', 2014` SEQ# L12070400260 A L1 CERTIFICATE OF LIABILITY INSURANCE DATE 1131 2013 DIYYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Bateman Gordon and Sands 3050 North Federal Hwy Lighthouse Point FL 33064 CONTACT NAME: (Arco" c. Exn :954-941 -0900 is , No►:954- 941 -2006 E-MAIL ADDREssecastillo @bgsagency.com INSURERS) AFFORDING COVERAGE NAIC # INSURER A:AmerisUre Insurance Co. 19488 INSURED CLAAI 1 Classic Air, Inc. 7801 W 25 Court Hialeah FL 33016 INSURER B : GL20431240602 INSURER C : 2/1/2014 INSURERD: $1,000,000 INSURER E : $100,000 INSURER F : $5,000 COVERAGES CERTIFICATE NUMBER: 1146493311 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR LTR TYPE OF INSURANCE ADDL INSR SUBR WVD POUCY NUMBER POLICY EFF (MM/DDIYYYY) POUCY EXP (MM/DDtYYYY) LIMITS A GENERAL X LIABILITY COMMERCIAL GENERAL LIABILITY GL20431240602 2/1/2013 2/1/2014 EACH OCCURRENCE $1,000,000 PREMISES (Ea occurrence) $100,000 MED EXP (Any one person) $5,000 CLAIMS -MADE X OCCUR PERSONAL & ADV INJURY $1,000,000 X Contractual GENERAL AGGREGATE $2,000,000 X XCU PRODUCTS - COMP/OP AGG $2,000,000 GEN'L AGGREGATE 7 POLICY X LIMIT APPLIES TER- PER: LOC $ A AUTOMOBILE X X LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS X SCHEDULED N NON-OWNED AUTOS CA20066271002 2/1/2013 2/1/2014 COMBINED SINGLE LIMI f (Ea accident) $1,000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE $ (Per accident) $ A X UMBRELLALIAB EXCESS LIAB X OCCUR CLAIMS -MADE CU20066351102 2/1 /2013 2/1/2014 EACH OCCURRENCE $5,000,000 AGGREGATE $5,000,000 $ DED X RETENT ON $0 A WORKERS COMPENSATION AND EMPLOYERS' UABIUTY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y/ N N N / A WC20066171101 2/1/2013 2/1/2014 X WC STATU- TORY LIMITS OTH- ER E.L. EACH ACCIDENT $1,000,000 E.L. DISEASE - EA EMPLOYEE $1,000,000 E.L DISEASE - POUCY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, K more space Is required) CERTIFICATE HOLDER CANCELLATION i City of Miami Shores Building & Zoning 10050 NE 2 Avenue Miami Shores FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ACORD 25 (2010/05) © 1988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD . . PRINTED WITH ENVIRONMENTALLY FFUENDLY INKS , • FSC Mixed Sources Pmdttai wasp *am volktusespeat to* smx1 atbercootrollotl moan cuort.aatwousura City of Hialeah Business Tax Receipt Mayor Carlos Hernandez WWWW 2012-13 Residential System Sizing Calculation Summary Project Title: DAVID ROMANIK RES A -C REPLACEMENT DAVID ROMANIK 95 NE 95 ST MIAMI SHORES, FL 33266- Code Only Professional Version Climate: South Location for weather data: Miami - Defaults: Latitude(25) Altitude(11 ft.) Temp Range(L) Humidity data: Interior RH (50 %) Outdoor wet bulb (77F) Humidity difference(58qr.) v -v v Winter design temperature Winter setpoint Winter temperature difference 50 F 70 F 20 F Summer design temperature Summer setpoint Summer temperature difference 90 F 75 F 15 F Total heating load calculation 45557 Btuh Total cooling load calculation 60926 Btuh Submitted heating capacity Total (Electric Strip) % of calc Btuh 74.6 34000 Submitted cooling capacity Sensible (SHR = 0.75) Latent Total % of calc Btuh 91.3 46125 147.6 15375 100.9 61500 WINTER CALCULATIONS Winter Heating Lo Load component Load Load Window total 1864 Window total 1864 sqft 22368 Btuh Wall total 2700 sqft 7376 Btuh Door total 20 sqft 216 Btuh Ceiling total 3600 sqft 3529 Btuh Floor total 240 sqft 5664 Btuh Infiltration 151 cfm 3325 Btuh Duct loss Sens. Ventilation 140 cfm 0 Btuh Subtotal 50513 42479 Btuh Ventilation 140 cfm 3079 Btuh TOTAL HEAT LOSS Btuh Latent gain(ventilation) 45557 Btuh Summer Cooling Loa CeWngs(B%) SUMMER CALCULATIONS Load component Load Window total 1864 sqft 23447 Btuh Wall total 2700 sqft 7118 Btuh Door total 20 sqft 324 Btuh Ceiling total 3600 sqft 13059 Btuh Floor total 0 Btuh Infiltration 81 cfm 1336 Btuh Internal gain 2920 Btuh Duct gain 0 Btuh Sens. Ventilation 140 cfm 2309 Btuh Total sensible gain 50513 Btuh Latent gain(ducts) 0 Btuh Latent gain(infiltration) 3194 Btuh Latent gain(ventilation) 5520 Btuh Latent gain(intemal /occupants /other) 1700 Btuh Total latent gain 10413 Btuh TOTAL HEAT GAIN 60926 Btuh Version 8 For Florida residences only Wndows(49%) CeNngs(21 %) EnergyGauge® System Sizing PREPARED BY: DATE: EnergyGauge® FLRCPB v4.5.2 System Sizing Calculations - Winter Residential Load - Whole House Component Details Project Title: Code Only 95 NE 95 ST DAVID ROMANIK RES A -C REPLACEMENT Professional Version MIAMI SHORES, FL 33266- Climate: South DAVID ROMANIK Reference City: Miami (Defaults) Winter Temperature Difference: 20.0 F 5/7/2013 Window Panes /SHGC /Frame /U Orientation Area(sgft) X HTM= Load 1 2 3 4 2, SHGC =0.5, Metal, 0.60 N 880.0 12.0 2, SHGC =0.5, Metal, 0.60 E 64.0 12.0 2, SHGC =0.5, Metal, 0.60 S 440.0 12.0 2, SHGC =0.5, Metal, 0.60 W 480.0 12.0 Window Total 1864(sgft) 10560 Btuh 768 Btuh 5280 Btuh 5760 Btuh 22368 Btuh Walls 1 2 3 Type R -Value Area X HTM= Light Weight CB - Ext(0.12) 4.1 1080 2.5 Light Weight CB - Ext(0.12) 4.1 270 2.5 Concrete BIk,Hollow - Ext(0.15) 4.1 1080 3.0 Load 2697 Btuh 674 Btuh 3204 Btuh 4 Concrete Blk,Hollow - Ext(0.15) 4.1 270 3.0 Wall Total 2700 801 Btuh 7376 Btuh Doors 1 Type Area X HTM= Wood - Exterior 20 10.8 Door Total 20 Load 216 Btuh 216Btuh Ceilings 1 Type /Color /Surface R -Value Area X HTM= Unvented Attic/D /Shin 19.0 3600 1.0 Ceiling Total 3600 Load 3529 Btuh 3529Btuh Floors 1 Type R -Value Size X HTM= Slab On Grade 0 240.0 ft(p) 23.6 Floor Total 240 Load 5664 Btuh 5664 Btuh Envelope Subtotal: 39153 Btuh Infiltration Type ACH X Volume(cuft) walls(sqft) CFM= Natural(Adjusted for ventilation) 0.28 32400 2700 151.2 3325 Btuh Ductload (DLM of 0.000) 0 Btuh All Zones Sensible Subtotal All Zones 42479 Btuh Subtotal Sensible Ventilation Sensible Total Btuh Loss 42479 Btuh 3079 Btuh 45557 Btuh EnergyGauge® FLRCPB v4.5.2 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) DAVID ROMANIK Project Title: Code Only 95 NE 95 ST DAVID ROMANIK RES A -C REPLACEMENT Professional Version MIAMI SHORES, FL 33266- Climate: South 5/7/2013 1. Electric Strip 34000 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U- Factor or'DEF' for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for slab -on -grade or area for all other floor types ) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5.2 Page 2 System Sizing Calculations - Winter Residential Load - Whole House Component Details Project Title: Code Only Professional Version Climate: South 5/7/2013 DAVID ROMANIK 95 NE 95 ST DAVID ROMANIK RES A -C REPLACEMENT MIAMI SHORES, FL 33266 - Reference City: Miami (Defaults) Winter Temperature Difference: 20.0 F Window Panes /SHGC /Frame /U Orientation Area(sqft) X HTM= Load 1 2 3 4 2, SHGC =0.5, Metal, 0.60 N 880.0 12.0 2, SHGC =0.5, Metal, 0.60 E 64.0 12.0 2, SHGC =0.5, Metal, 0.60 S 440.0 12.0 2, SHGC =0.5, Metal, 0.60 W 480.0 12.0 Window Total 1864(sgft) 10560 Btuh 768 Btuh 5280 Btuh 5760 Btuh 22368 Btuh Walls 1 2 3 4 Type R -Value Area X HTM= Light Weight CB - Ext(0.12) 4.1 1080 2.5 Light Weight CB - Ext(0.12) 4.1 270 2.5 Concrete BIk,Hollow - Ext(0.15) 4.1 1080 3.0 Concrete BIk,Hollow - Ext(0.15) 4.1 270 3.0 Wall Total 2700 Load 2697 Btuh 674 Btuh 3204 Btuh 801 Btuh 7376 Btuh Doors 1 Type Area X HTM= Wood - Exterior 20 10.8 Door Total 20 Load 216 Btuh 216Btuh Ceilings 1 Type/Color /Surface R-Value Area X HTM= Unvented Attic/D /Shin 19.0 3600 1.0 Ceiling Total 3600 Load 3529 Btuh 3529Btuh Floors 1 Type R -Value Size X HTM= Slab On Grade 0 240.0 ft(p) 23.6 Floor Total 240 Load 5664 Btuh 5664 Btuh Envelope Subtotal: 39153 Btuh Infiltration Type ACH X Volume(cuft) walls(sqft) CFM= Natural(Adjusted for ventilation) 0.28 32400 2700 151.2 3325 Btuh Ductload (DLM of 0.000) 0 Btuh All Zones Sensible Subtotal All Zones 42479 Btuh Subtotal Sensible Ventilation Sensible Total Btuh Loss 42479 Btuh 3079 Btuh 45557 Btuh EnergyGauge® FLRCPB v4.5.2 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) DAVID ROMANIK Project Title: Code Only 95 NE 95 ST DAVID ROMANIK RES A -C REPLACEMENT Professional Version MIAMI SHORES, FL 33266- Climate: South 5/7/2013 1. Electric Strip 34000 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U- Factor or'DEF' for default) (HTM - Manua lJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for slab -on -grade or area for all other floor types ) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5.2 Page 2 System Sizing Calculations - Summer Residential Load - Whole House Component Details DAVID ROMANIK Project Title: 95 NE 95 ST DAVID ROMANIK RES A -C REPLACEMENT MIAMI SHORES, FL 33266- Reference City: Miami (Defaults) Summer Temperature Difference: 15.0 F Code Only Professional Version Climate: South 5/7/2013 EnergyGauge® FLRCPB v4.5.2 Page 1 Window Type* Pn/SHGC/U /InSh/ExSh/IS Omt Overhang Len Hgt Window Area(sqft) Gross Shaded Unshaded HTM Shaded Unshaded Load 1 2 3 4 2, SHGC =0.5, 0.60, B-L, N,H N 2, SHGC =0.5, 0.60, B -L, N,H E 2, SHGC =0.5, 0.60, B-L, N,H S 2, SHGC =0.5, 0.60, B-L, N,H W Window Total 12ft. 1ft. 3ft. 1ft. 3ft. 1ft. 3ft. 1ft. 880.0 0.0 880.0 64.0 64.0 0.0 440.0 440.0 0.0 480.0 480.0 0.0 1864 (sqft) 13 13 13 36 13 14 13 36 11070 Btuh 805 Btuh 5535 Btuh 6038 Btuh 23447 Btuh Walls 1 2 3 4 Type R- Value /U -Value Area(sqft) HTM Light Weight Concrete Block -I - Ext 4.1/0.12 1080.0 2.4 Light Weight Concrete Block -I - Ext 4.1/0.12 270.0 2.4 Concrete BIk,Holiow - Ext 4.1/0.15 1080.0 2.9 Concrete BIk,Hollow - Ext 4.1/0.15 270.0 2.9 -2-700 -(sgft) Load 2602 Btuh 651 Btuh 3092 Btuh 773 Btuh -Btuh -AA/all -Total 7-1-1- 8 Doors 1 Type Area (sqft) HTM Wood - Exterior 20.0 16.2 Door Total 20 (sqft) Load 324 Btuh 324 Btuh Ceilings 1 Type /Color /Surface R-Value Area(sqft) HTM Unvented Attic/DarkShingle 19.0 3600.0 3.6 Ceiling Total 3600 (sqft) Load 13059 Btuh 13059 Btuh Floors 1 Type R -Value Size HTM Slab On Grade 0.0 240 (ft(p)) 0.0 Floor Total 240.0 (sqft) Load 0 Btuh 0 Btuh Envelope Subtotal: 43948 Btuh Infiltration Type ACH Volume(cuft) wall area(sqft) CFM= SensibleNatural 0.15 32400 2700 151.2 Load 1336 Btuh Internal gain Occupants Btuh /occupant Appliance 4 X 230 + 2000 Load 2920 Btuh Sensible Envelope Load: 48204 Btuh Duct load (DGM of 0.000) 0 Btuh Sensible Load All Zones 48204 Btuh EnergyGauge® FLRCPB v4.5.2 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) DAVID ROMANIK Project Title: Code Only 95 NE 95 ST DAVID ROMANIK RES A -C REPLACEMENT Professional Version MIAMI SHORES, FL 33266- Climate: South 5/7/2013 Whole House Totals for Cooling Sensible Envelope Load All Zones Sensible Duct Load Total Sensible Zone Loads Sensible ventilation Blower Total sensible gain Latent infiltration gain (for 58 gr. humidity difference) Latent ventilation gain Latent duct gain Latent occupant gain (4 people @ 200 Btuh per person) Latent other gain Latent total gain TOTAL GAIN 48204 Btuh 0 Btuh 48204 Btuh 2309 Btuh 0 Btuh 50513 Btuh 3194 Btuh 5520 Btuh 0 Btuh 800 Btuh 900 Btuh 10413 Btuh 60926 Btuh 1. Central Unit 61500 Btuh `Key: Window types (Pn - Number of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U - Window U- Factor or'DEF' for default) (InSh - Interior shading device: none(N), Blinds(B), Draperies(D) or Roller Shades(R)) (ExSh - Exterior shading device: none(N) or numerical value) (BS - Insect screen: none(N), Full(F) or Half(H)) (Omt - compass orientation) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5.2 Page 2