Loading...
MC-12-1629Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 C t� Inspection Number: INSP- 177959 Permit Number: MC -8 -12 -1629 Scheduled Inspection Date: March 18, 2013 Inspector: Perez, JanPierre Owner: MAGEE, PHILIP & LISA Job Address: 780 NE 94 Street Miami Shores, FL 33138- Project: <NONE> Contractor: ALL YEAR COOLING AND HEATING Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number (305)469 -2281 Parcel Number 1132060141650 Phone: (954)566 -4644 Building Department Comments 4 TON AC REPLACEMENT q2-e 31)0 Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. March 15, 2013 For Inspections please call: (305)762 -4949 Page 4 of 54 ' 1 Ia4((1 UI DING PERMIT APPLICATION FBC 20 IL' Permit Type: MECHANICAL Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 z kr 0 AUG(3 U 2pi2 J� Permit No. Master Permit No. 12- ° I Lo OWNER: Name (Fee Simple Titleholder): Pt' 1 L tp oY ' M ekT6 4 LIS& Phone #:. OE -333 '" S Address:1' O 4 ST • City: tLA.i S k or e.,.S State: Zip: 33162 Tenant/Lessee Name: Phone #: 3 Email: JOB ADDRESS: '71 4 mot' ST City: Miami Shores County: Miami Dade Zip: 33 ) 3 2 Folio/Parcel #: t 1 -32010 - 014-1/0S-0 Is the Building Historically Designated: Yes NO ✓ Flood Zone: X CONTRACTOR: Company Name: -Al 1 LI Car- 0Qn 1 f nj /4 Lk[lkj Phone#: fl5V -s 4 46 T 9 Address: (•i% 1 W • Sun r1.S -e, 151VC City: 1 /.irT+CL vY \ State: I' rr �-- i • Zip: 333 13 Qualifier Name: firY� as S m 1 T� 1 Phone#: q34- .610-4/47 (At State Certification or Registration #: C-DS$ I SGI Certificate of Competency #: e-/hc S3 7 Contact Phone #: q f STo 4- 4414y X. 3-7S- Email Address: P4i/nl " tS A''IC, 24.1 K • GtJ DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ 33a:S. Square/Linear Footage of Work: Type of Work: Address DAlteration New 5Repair/Replace �O/Demolition Description of Work: e. f t C ( are Z.) �T a �On !'F1'e'01't S� l;-. St js-1-e.fi'► . Its Icc.- Ito �s ear y- a / gt u.t-ft Le",�-� * ****** * * * * * * * * ** * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ Permit Fee $ CF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ '�_ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will np be approved d a inspection fee will be charged. Signature Owner orrAa nt Signature /�1 / % /-` Contractor The foregoing instrument was acknowledged before me this ° k The foregoing instrument was acknowledged before me thisL4 day of a , -20 d= P , by D J 1 .I C' 6� as rr7e 2 , day of �L who i who is personally known to me or who has (produced , 20 /a , by a1Y)QS ,9 .S6:1 or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: - (1� Print: My Commission Epires: e6 L �� * * * * * * * * * * * * * * * * * * * ** APPROVED BY Notary Public Tres Sep 15, My Comm. Expires 2013 Commission # DD 924860 :o sed rough National Notary Assn. Sign Print: My Comm INGRYS FARIAS Notary Public e State of Florida • My Comm. Expires Sep 15, 2013 Commission # DD 924860 * * * * * * * * * * * * * ** Examiner Structural Review (Revised 07!10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) * Zoning Clerk Today's Comfort... Yesterday's Prices. 6781 W. Sunrise Boulevard, Plantation, FL 33313 Phone: (954) 566.4644 Fax: (954) 667 -1290 www .allyearcoolingandheating.com Est. 1973 with over 150,000 Installations PURCHASER'S NAME YM ( L A 4 AC e- ADDRESS 7 &•!1 N 2- 7 , k CITY /STATAAE ZIP _ z '� �g5 r t- 33: I E -MAIL r ✓j1 i-f (> J #4 wee e.. to L, . c t. HOME PHONE REFERRED BY CELL PHQN(3't? • ❑ I WOULD IJKE TO RECEIVE NEWS, UPDATES, OFFERS AND PROMOTIONS VIA SMS TEXT MESSAGING INDOOR AIp IMPROVEMENT ❑ Duct Cleaning & Sanitizing# Vents# of D ❑ W Light E -CONTRACT U'tSTIMATE N° DATE: g—1 -f'( CONTRACT We hereby submit specifications for: iuipment Installation ❑ Indoor Air Quality ❑ Other All Year Cooling will fumish all parts, labor and equipment necessary to facilitate the service checked above in accordance with the conditions and specifications listed In this contract. Does not include electrical upgrade unless stated. ystems ❑ High Quality Air Filter ❑ High Quality Air Cleaner RETURN & SUPPLY DISTRIBUTION latiodify/New Supplyeaettsr- e V ❑ New Supply Grill, Size ❑ Modify/New Retum Duct(s) ❑ Seal Up Leaks in Ducts # ❑ New Return Air Grill, Size x Qty. ❑ Modifications of Else m ❑ Retum Air Plenum ocatlon Location plit System ❑ Package Unit 110JIHeatiump na.aght Cool ❑ Horizontal Application ❑ Other NEW EQUIPMENT a 1 ectric Heat ❑ Heat ery Unit ❑ Attic aypticalAcation WIRING dier Breaker Wire Size Existing Breaker ❑ Replace Breaker CI-Kew Breaker ❑ Brand ],Qondasnser Breajar•Wire 6, Existing Breaker ❑ Replace Breakgr /� ❑ Brand e i i New Breaker Eieefilcal Disconnect Box ❑ Provided by All Year Cooling Existing Electrical lYto' Code it 2 3 92 LI M'find ■ Switch aftfilliary Float Safety Switch e of Thermostat - Specify Type Wea» r Resistant Vibration, Isolation Pads 1 Visit Maintenance Agreement 5 Year Extended Warranty 0 10 Year Extended Warranty CONDENSATION & COPPER PIPING 10-015idensate Drain Hook -Up ! -`mart' ❑ Secondary ❑ New Condensate Pump ❑ Auxill a an 0-refrigerant Copper Liquid Line, Size jj(( j( ■ ilities and Workmen's Comp for Our Work Performed with Existing Codes nting Hardware of Stand forAir Hand ❑ Hurricane Code Strapping' - 1 Year Warranty by All Year Cooling on work performed, and manufacturer's warranty on equipment unless otherwise stated below. Labor provided by seder In be period is Monday through Sunday. INVESTMENT BREAKDOWN Subtotal $ 040$ $ Permit $ 't` /S?) $ $ Utility Rebate $ 7S4r) $ $ Man. Rebate $ /$ $ We Credits $ ..- �a $ $ Total Investments $ $ $ Extended Warranty $ $ $ Balance Due $ 3/3 Z,c$ $ Awi Duo financing to Twineden'� U be prior to of Job starting ` work. t - AS Year Coating efrigerant Copper Suction Line with insulation, Size Length of R or OTHER s'` sting Copper ❑ Refrigerant Line Cover ❑ Smoke Detector - Existing/New ❑ Straps ❑ G enie Lift ❑ Extend Slab w Slab ❑ Labor Needed ft RRANTIES Manufacturer's • . i pressor denser ie Evan Coil Wa ntles Years Years lr._./Years Et-Parts—V - Years WORK PERFORMED 4' > U A) -- _Years DETAILS OF Lt /1/e, _.: 7 /�—r — - 6 4_4u 41.41 Farm of P mat [l Cash LUG • cc • Femme Ucense # CAC056159, 94CME15063, 516711, 08E000413, ER0012903 g�f7 SEE FO AND CONDITIONS Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC 13 —1W This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): i 940 ci 4 ST • City: Miami Shores Village County: Miami Dade Zip Code: 3313 g ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES ❑ NO Er- ARHI Sheet Attached: YES Er NO ❑ Contract Attached: YES ©"" UNIT BEING REPLACED DATA NEW UNIT ejy.yy -1 MANUFACTURER CZ 1,e 2-61-1 L21 AHU or PKG. UNIT MODEL # RI- tL14 1u kill 2. 1 (?-ozv 101 Ll yZ COND. UNIT MODEL # ifLwalrt (1-4 10 KW HEAT i 10 4 NOM TONS 1 y AHUSO CU �}0 PKG 1) M , ! �` � � So AHU � CU le PKG AHU 40 CU $b PKG 2) M,O.P , ;) ' ` ` AHU60 CU St) PKG AHUL3o CUV)C PKG 3) VOLTS _ AHUt3DCUZ30 PKG PKG UNIT / /;,`, �' �� : PKG UNIT / / EER/SEER 1(0 YES Km REPLACING DUCTS.; YES CW NO REPLACING THERMOSTAT i NO <n) NO NEW 4 °CONCRETE SLAB 414'10 NO YES Ea t% NEW ROOF STAND YES CO4 YES +/olio NEW RETURN PLENUM BOX YES CNC) 1. Minimum Circuit Ampacity (Wire Size): (via, 2. Maximum Overcurrent Protection (Fuse /Breaker Size): (Do akikps 3. Voltage of Circuit (208/240/480): cD 't`U 4. Size Disconnecting Means: c� Contractor's Company Name: ` hOtneS A • Sra"tl Phone: 6i',Sti-S66 -46 q State Certificate or Registratio ChCo521S1 Certificate of Competency N. Chi -')C. S 3 oDamps Signature Date: (2/a_ i 1 !a A uo� ru...1 CERTIFIEDT www.ahiidireeto y.org This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011. Certificate of Product Ratings AHRI Certified Reference Number: 3799429 Date: 8/29/2012 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 14AJM49 Indoor Unit Model Number: RHLL- HM4821 +RCSL -H *4821 Manufacturer: RHEEM MANUFACTURING COMPANY Trade /Brand name: RHEEM 14AJM SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): EER _Rating,(Qo. ling) ;.. SEER Rating (Cooling): 46000* * Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The lnformatlon for the model cited on this certificate can be verified at www.ahridirectory org, click on "Verify Certificate" Zink and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute 111 Air - Conditioning, Healing, and Refrigeration Institute CERTIFICATE NO.: 129907174723983764 9 Load Short Form Entire House ALL YEAR COOLING AND HEATING 1345 NE 4TH AVE, FORT LAUDERDALE, FL 33304 Phone: 954 566 4644 Fax: 954 640 0200 Web: ALLYEARCOOLINGANDHEATING.COM Job: Date: By: Project Information For: MAGEE 780 NE 94 ST, MIAMI SHORES, FL Design Information Outside db ( °F) Ins ide db (°F) Design TD ( °F) Daily range Inside humidity ( %) Moisture difference (gr/Ib) Htg 51 70 20 CIg 90 75 15 L 30 50 -11 57 Method Construction quality Fireplaces Infiltration Simplified Average 0 HEATING EQUIPMENT Make Trade Model AHRI ref no. n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 27232 Btuh 16 °F 1533 cfm 0.056 cfm /Btuh 0 in H2O COOLING EQUIPMENT Make Rheem Trade RHEEM 14AJM SERIES Cond 14AJM49 Coil RHLL- HM4821 + +RCSL -H *4821 AHRI ref no. 3799429 Efficiency 13.0 EER, 16 SEER Sensible cooling 32200 Btuh Latent cooling 13800 Btuh Total cooling 46000 Btuh Actual air flow 1533 cfm Air flow factor 0.042 cfm /Btuh Static pressure 0 in H2O Load sensible heat ratio 0.81 ROOM NAME Area (ft/) Htg Toad (Btuh) CIg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) LIV /DINE/KIT 900 14859 19795 837 831 BEDROOM 1 200 2817 3856 159 162 BEDROOM 2 150 2838 3837 160 161 BEDROOM 3 150 2655 3699 150 155 BATH 1 100 1647 1962 93 82 BATH 2 100 1259 1923 71 81 HALLWAY 300 1157 1468 65 62 Entire House 1900 27232 36540 1533 1533 Other equip loads 0 0 Equip. @ 0.95 RSM 34859 Latent cooling 8357 rr. -r., .. anon n-snnn A,3,14 '7 i A,VI 1iigq Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right- Suite® Universa1201212.0.07 RSU12433 ...CALC\ROOM BY ROOM\ROOM BY ROOM - 8375 SW 102 ST - 3- 2- 1900.rup Calc = MJ8 House faces: N 2012-Aug-29 13:34:00 Page 1 Project Summary Entire House ALL YEAR COOLING AND HEATING 1345 NE 4TH AVE, FORT LAUDERDALE, FL 33304 Phone: 954 566 4644 Fax: 954 640 0200 Web: ALLYEARCOOLINGANDHEATING.COM Job: Date: By: Project information For: MAGEE 780 NE 94 ST, MIAMI SHORES, FL Notes: Desi • n Information Weather: Miami, FL, US Winter Design Conditions Outside db 51 °F Inside db 70 °F Design TD 20 °F Heating Summary Summer Design Conditions Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 °F 75 °F 15 °F L 50 % 57 gr/Ib Sensible Cooling Equipment Load Sizing Structure 27232 Btuh Structure 36540 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27232 Btuh Use manufacturer's data n Rate /swing multiplier 0.95 Infiltration Equipment sensible Toad 34859 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 8357 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1900 1900 Equipment latent load 8357 Btuh Volume (fig) 15200 15200 Air changes/hour 0.38 0.20 Equipment total load 43217 Btuh Equiv. AVF (cfm) 96 51 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make Trade Model AHRI ref no. n/a Make Rheem Trade RHEEM 14AJM SERIES Cond 14AJM49 Coil RHLL- HM4821 + +RCSL -H *4821 AHRI ref no. 3799429 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 0 Btuh Sensible cooling 32200 Btuh Heating output 27232 Btuh Latent cooling 13800 Btuh Temperature rise 16 °F Total cooling 46000 Btuh Actual air flow 1533 cfm Actual air flow 1533 cfm Air flow factor 0.056 cfm /Btuh Air flow factor 0.042 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. IiMight8011" RightSuite® Universal 2012 12.0.07 RSU12433 ...CALC\ROOM BY ROOM\ROOM BY ROOM - 8375 SW 102 ST - 3- 2- 1900.rup Calc = MJ8 House faces: N 2012-Aug-29 13:34:00 Page 1 Manual S Compliance Report Entire House ALL YEAR COOLING AND HEATING 1345 NE 4TH AVE, FORT LAUDERDALE, FL 33304 Phone: 954 566 4644 Fax: 954 640 0200 Web: ALLYEARCOOLINGANDHEATING.COM Job: Date: By: Project 1 nformation For: MAGEE 780 NE 94 ST, MIAMI SHORES, FL Cooling Equipment Design Conditions Outdoor design DB: 90.4 °F Outdoor design WB: 77.4 °F Indoor design DB: 75.0 °F Indoor RH: 50% Sensible gain: 36540 Btuh Latent gain: 8357 Btuh Total gain: 44898 Btuh Estimated airflow: 1533 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Rheem Actual airflow: 1533 cfm Sensible capacity: 32200 Btuh Latent capacity: 13800 Btuh Total capacity: 46000 Btuh Model: 1 4AJM49 +RH LL -H M4821 + +RCSL -H *4821 88% of load 165% of load 102% of load SHR: 70% Entering coil DB: 75.0°F Entering coil WB: 62.5°F Heating Equipment Conditions Outdoor design DB: 50.5 °F Indoor design DB: 70.0 °F Heat Toss: 27232 Btuh Manufacturer's Performance Data at Actual Design Conditions Equipment type: Elec strip Manufacturer: Actual airflow: Output capacity: 1533 cfm 27232 Btuh Model: 100% of load The above equipment was selected in accordance with ACCA Manual S. Entering coil DB: 70.0°F Temp. rise: 0 °F h fr Rig ht-Su ite® U nlversal 2012 12.0.07 RSU12433 ...CALC \ROOM BY ROOM\ROOM BY ROOM - 8375 SW 102 ST - 3- 2- 1900.rup Calc = MJ8 House faces: N 2012-Aug-29 13:34:00 Page 1