Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-13-473
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 187123 Permit Number: RF- 3- 13-473 Inspection Date: March 19, 2013 Inspector: Bruhn, Norman Owner: EAST CONDOMINIUM INC, SHORES DI A7A Job Address: 735 NE 91 Street BLDG E Miami Shores, FL 33138 -0000 Project: <NONE> Contractor: ALL CONSTRUCTION & DEVELOPERS INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 113206044001 Phone: (786)768 -4330 Building Department Comments TILE ROOF REPAIR Infractio Passed Comments INSPECTOR COMMENTS True Passed V.�1 Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until April 04, 2013 For Inspections please call: (305)762 -4949 Page 1 of 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 B IL ING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: 735 NI E COT,STrt ea MAR . i O13 FBC 20 P Permit No. Master Permit No. °-74' ROOFING City: Miami Shores County: Miami Dade Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: .7 M 0 Zip: 133 OWNER: Name (Fee Simple Titlehold- Address: 7 Ne. ct i/4wti ort 5 ) State: i- Zip: 03 13 °v City: bits 'Aii-AyA FAST C_sl'INA D T(e Phone ! `5' N 1 .q0 GA Tenant/Lessee Name: Phone #: Email: CONTRACTOR: Company N e: 411 7a'St'Y't,L1C vC)a c5 Q6 IO/ / tie Phone #: (77 c '1.40 Address: /D ©D 2 3 t9 s' 4'4 3d c a , ()O--' City: {je" State: Pi Qualifier Name: ,t J az (M& /Oic. State Certification or Registration #: C C. / 3 2- /A/5- Certificate of Competency #: Contact Phone #: '�% /, t, 7 7 LP Sas-1A it ss: DESIGNER: Architect/Engineer: Phone #: Zip: 33 / 3 2 Phone #: Value of Work for this Permit: $ Square/Linear Footage of WorkP, Type of Work: ❑Addition OAlteration ❑New Description of Work: £ IZG rt°F T r 0 QDOF Work:, pa r ORepair/Replace ODemoliition Color thru tile: ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ 5O Permit Fee $ C / ©� CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 111 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee, vill be charged. Signature NPt Signature.�.c�� 0 or gent Contractor The foregoing ' s trument was ac aQ ,, edged before me this IS- t„ �1. The foreg:' i instrument was acknowledged before me this day of �b1 414(, 20 13, by ![ o 4 ltT 6(N4,4 tt? , day of ,20 f 3 , by 4/1G/ cJ COVrtdcw- . who isEersonally known to motor who has produced who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: .Sign: Prince.: My Commission Expires: * ** * * * * * * * * * * * * * * * * * * * * * * ** * * ** *' ,* APPROVED BY as identification . who did take an oath. IGIRIO Sign: Print: My Commission Exp ********************** * * * * * * * * * * * * ** * * * * * * * * * * * * * * * ** Plans Examiner Zoning Structural Review Clerk (Revised 5 /2 /2012XRevised 3/12/2012) )(Revised 06 /10/2009XRevised 3 /15 /09)(Revised 7/10/2007) The Shores Plaza East Condominium .sissociation, Inc. Miami Shores Village Building Dept. 10050 NE 2nd Avenue Miami Shores, FL 33138 Dear Sir / Madam: 745 North East 91st Street Miami Shores, FL 33138 305- 759 -9069 / FAX 305- 759 -2101 E-MAIL spe123@atii,net February 25, 2013 This letter will serve as your confirmation that "All Construction" has been contracted and is authorized by the Board of Directors of the Shores Plaza East Condominium Association to perform roof repairs at building 735 NE 91st Street, Miami Shores, Fla. Should you have any questions regarding the enclosed, please feel free to contact the condominium office. Sincerely yours, re-,/ Robert Gonzalez President cc: file ROOF ASSEMBUES AND ROOFTOP STRUCTURES Master Permit No . UII'ine' Ef\TE Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform PermitAppllcatlon Fink ` "f .f i, ,r,,f H ALL FEDERAL Section A (General Irfnrrnatinn) Contractor's Name' . . _ Job Address133 q l Process No. Cms-rocrilyi ❑ Low Slope ❑ Asphaltic Shingles Sfi ' M )a I E , �l Ior2 J, ❑ Mechanically Fastened Tile Mortar /Adhesive Set Tile ❑ Metal Panel/Shingles ❑ ood Shingles/Shakes ❑ Prescriptive BUR -RAS 160 ROOF TYPE ❑ New Roof ❑ Reroofing ❑ Recovering 1 Repair 0 ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Pk 6.F Sar_tinn R (Roof Plan). Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. I"4.71;7';:3 Tota (SF) 40. sE NO 6AS FLORIDA BUILDING CODE — BUILDING The Shores Taza East Condort tium Association, Inc. 748 North East 9'101 Street Miami Shores, Ft. 33138 305-759-9089 - I iotCe/Fax ost- E-M411 Property Layout S W N A- Cundu S Pulit a Offers 0- Ste+rear C- t tundra I : 300- ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High-Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sl_opeJ Roof System) Roof System Manufacturer: Lamoti. Raol. TIk Notice of Acceptance Number: 06-1114.0+ Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: P2: P3: Maximum Design Pressure (From the Product Approval Specific System): 1 34 Roof Slope: 12 _ • Ridge Isittion-? • McAn Root Heignt: '77 6 7 Steep Sloped Roof System Description Deck Type: \Nlooci 146 TftG Type Underlayment: SL.:11E160W Fire Barriei 30 AsTM fa+ MIA Fastener Type 8- Spacing: PI'4 4 41'Atit1 ) 4/146n iatrs 2 vws Sol 6.0..4m. Akt VIOL Poi y j.D�A Adhesive TI,ype: Type cap Sheet: Rc-of Covering; 1 Ply Mod .Prumto (GAF) (1 Valit4+101. Moak %odd) 1.0.1mati, (AMU' th Type & Size Drip Edge: K1. FLORIDA BUILDING CODE — BUILDING SECTIOi4 1524 HiGH VELOCITY HURRICANE ZONES REQUIRI{D OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility; of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Fkxida Building Code, Building govem the minimum tequirements and standards of the industry for roofing system installations. Additionally, the following items shou,d be addressed as part of the agreement between the ov�r3e�r acrd the contractor. The owner's initial in the adjacent box indicates that the item has been explained. . Aesthetics-Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) the purpose of providing that the roofing systtam meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship • Aesthetic issues such as color or architectural {appearance, that are not part of a zoning code, should ed as part of the agreement between the ownerand the contractor. Renaiiing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed ance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building roof deck is usually concealed prior to removint l the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring .e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner notify the occupants of adjacent units of roofing wove to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be from below. The owner may wish to maintain ie architectural appearance, therefore, roofing nail Orations of the underside of the decking may not be acceptable. The Florida Building Code provides the • ,., 4 maintaining this appearance. 5. Ponding Water The current roof system andjfor deck of the building may not drain well and may ca' water to pond (accumulate) in low -lying areas of ;`the roof. Ponding can be an indication of structural distress and may require the review of a professional!', structural engineer. Ponding may shorten the Fife e : «t: and performance of the new roofing system. Ponding conditions may not be evident until the ordinal titosystem is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): it is required that rainwater flow off so that the roof is not ed from a build up of water. Perimeter /edge wali , or other roof extensions may block this discharge if ow scuppers (wall outlets) are not provided. It may b necessary to install overflow scuppers in accordance Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the yi aural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in *tending the service life of the roof. `135 NJE q( _T 'PA Pr, Address 2 31 Date Permit Number Rev :1120r1005,Computer Services, Building Department BUILDING AND NEIGHBORHOOD COMPLIANCE DE ,RTMENT 1BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street. Room 208 Miami. Florida 33175 -2474 T (786) 3 1 5 -2590 F (786) 315 -2599 www.miamidade.gov /building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated ';)elow. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assuran a purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been &signed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved". unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewa application has been filed and there has been no change in the applicable building code negatively affecting tl e performance of this product. TERMINATION of this NOA will occur after the expirationt date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall aunmatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the cords Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature: If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be providec to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the requ,st of the Building Official. This renews and revises NOA # 09- 0806.07 and consists of pa :ages I through 8. The submitted documentation was reviewed by Alex Tigera. Ir>IAMhDADE COUNTY APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page I of 8 ROOFING COMPONENT APPROVAL Category: Sub - Category: Material: Roofing Underlayment SBS , APP Self- Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Facer of Membrane with surface printing) Manufacturing Location #1 & #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3'33/8" Or 65' x 3' 80 mils thick Roll: 32'10" x 3'33/8" 100 mils thick Roll: 65' x 3'3 -I8„ 80 mils thick Roll: 32'10" x 3'3 - 3/8" 130 mils thick Roll: 61' x 3'3)W 60 mils thick Test Specification TAS 103 TAS 103 and ASTM D TAS 103 and ASTM D 19'20 TAS 103 and ASTfvI D 1970 TAS 103 anc' ASTM D 197) TAS 103 and ASTM D 197) Product Description A hamogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A fine granular /sand top surface self- adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non - wicking fabric surfaced, self - adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass- fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof rile underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 2 of R PRODUCTS DESCRIPTION: Product Polystick Dual Pro Manufacturing Location Dimensions Roll: 61' x 3'3 -3/8" 60 mils thick MANUFACTURING PLANTS: I. Haze1ton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC Trinity! ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test S ecificaticaa ASTM D 19.70 Test Identifier 11756.04.01-1 11756.08.01 -1 02202.08.05 P51 10.08.07 P 1 0870.09.08-R 1 P10870.04.09 P33360.06.10 P33370.03.1 1 P36900.09.1 1 PR101 1 1 1 PUSA- 005 -02 -01 PUSA- 018 -02 -01 PUSA - 035 -02 -01 PUSA- 033 -02 -0 ] PUSA- 055 -02 -02 PUSA- 083 -02 -01 PUSA-089-02-0 1 JX20H7A RX 14E8A DX23D8B DX23D8A Product Description A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. specific for use as a high temperature underlayment. Designed as a metal roofing. Test Name /Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/1 3/09 07/01/10 03/02/I1 09/01/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NJOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 3 of 8 INSTALLATION PROCEDURES: "Seek Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 plaits and tit caps 12" grid. 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS I 1 I . 3. Place the first course of membrane parallel to the eave., rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3 -V2" and end laps shall be a minimum of 6." Roll the membrane int.:) place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at tilt low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to ha re full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to e inuree a tight fit. A second layer of Polystick shall be applied over the underlayment. INJ O A No.: 11-0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 4 of 8 GENERAL LIMITATIONS: 1.- Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, ',vood shakes and shingles, non- structural metal roofing, roof tile systems and quarry skate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a SIT ooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments sha 1 not be: adhered directly over a pre - existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left expose 'I as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Bui ding Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the rooftile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened rooftile applications. Polystick IR-Xe, and Tile Pro are limited to mechanically fastened rooftile applications. Polystick MTS is limited to mechanically fastened with battens rooftile applications. Polystick TU P may be used in both adhesive set and mechanically fastened rooftile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as rooftile underlaymcnt for (direct-to-deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR-Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation • The above slope limitations can be exceeded only by us ng battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles_: at all times. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 5 of Y, GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to Beep foot traffic to a minimums and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. Roof Deck prepared with POLY 11CKTU Pius Roofing Tiles (6 Max Per Stack) 11. Refer to prepared roofing system Product Control Notie of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MT;, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided tc detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or icentifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. UILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copes of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or ;applicable building code in order to properly evaluate the installation of this materials. APPROVED NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR PGLYS41Ci< MEM1 1 ANES: l Polyglass does accept the direct application of ?oiystiok underiav,nent membranes to wood decks. installers are cautioned to refer to applicable local building code; prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, I 1 gauge ring shank type, applied with a minimum 1- metal disk as required in Dade County or simplex type nail as otherv'ise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and /or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.') 3. All seal lap seams (selvage laps) must be rolled with a :rand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end lads. shall have a 6" wide, uniform Layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 24 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement. or Wile-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the; lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 aid #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch /slopes in excess of 6'/ "/12 ", precautions should be taken, such as the use of battens to prevent ti!'e sliding during the loading process. 7. Minimum cure time after membrane installation & befc:re loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB :=lashing Cement, Polyglass P0500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing ::adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall )e a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for tie rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the reof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior' to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOS:) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 7 of f 13. Questions in regards to the application of Pots.giass products should be directed to our 'T-echnical Services Department at I (800) 894 -4563. 14. Polyglass recommends that applicators follow good rooting practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES IIEGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE: POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF T IS ACCEPTANCE NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 8 of 8 MIAMIDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Lamoti Roof Tile 1360 N.W. 29th st. Miami, FL 33142 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAML FLORIDA 33130-1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barrel High Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no .hange in the applicable building code negatively affectinf, the performance of this product. TERMINATION of thi..; NOA will occur after the expira ion date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall 2utomatically terminate this NOA. Failure to comply with ary section o; this NOA shall be cause for terminatioI and removal of NOA. ADVb,MTI E1VIENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literati re. If any portion of the NOA is displayed, then it shall be done in its entirety. INSI'EC-`TION:A eery of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the rcquest of the Building Official. This renews and revises NOA #02 -0205.09 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigeia. NOA No.:06- 1214.07 Expiration Date: 03/14/12 Approval Date: 06/28/07 Page 1 of 4 ROOFING ASSEMLY APPROVAL Category: Roofing Sub - Category: Tile Sub -Type: Concrete 1. SCOPE: This renews a roofing system using Lamoti Barrel High Profile Concrete Tile, as manufactured by Lamoti Roof Tile, described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code. For the locations where the pressure requirements, as determined by applicable building code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed n section 4 herein. The attachement calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Teyt Product Product Dimensions Specifications Description Barrel Concrete Tile Length : 18" TAS 112 High profile, two piece, concrete roof Width : 8 3/4" tile. For direct deck, adhesive set Thickness : 1/2" applications only. Trim Pieces Length : varies TAS 112 Accessory trim, concrete roof pieces for Width : varies use at hips, rakes, ridges and valley Varying thickness terminations. Manufactured for each tile profile. 2.1. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date IBA Consultants, Inc. 2358 -54 TAS -101 05/08/07 IBA Colsultants, Inc. 2358 -50 TAS -112 12/19/06 3. LIMITATION' • 3.1 Fire classification is not part of this acceptance 3.2 Fug alortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to rtform quartely test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Complii nce Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Application Standard listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building coce. 3.7 May be installed on slopes 2 ":12" to 7":12" NOA No.:06- 1214.07 Expiration Date: 03/14/12 Approval Date: 06/28/07 Page 2 of 4 4. INSTALATION: 4.1 Lamoti `Barrel high Profile Concrete Tile' and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 4.2 Data for Attachment Calculations: Table 1: Average Weight (W) and Dimensions (I x w) from TAS 112 Testing Tile Profile Weight -W (lbf) Length -1(feet) Width -w (feet) Barrel High Profile Concrete Tile 8.1 1.50 0.73 Table 2: Aerodynamic Multipliers - A (ft) A (ft3) Direct Deck Application Tile Profile A (ft3) Batten App ication Barrel High Profile Concrete lice N/A 0.23 Table 3: Restoring Moments due to Gravity - Mg 5 ":12" (ft-lbf) 6 ":12" Greater than 7 " :12" Tile Profile 2 ":12" 3 ":12" 4 ":12" Barrel High Profile Concrete Tile Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck 5.66 5.56 5.43 5.25 5.01 4.72 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile ;Application Minimum Attachment Resistance Barrel High Prcfiie. Concrete Tile Polyfoam Polypro AH 160TH AH 160TH for pan tile, 17.5 grams 77.871 on each side for cap tiles. 1 Paacy placgment.of 37 grams of Polypro 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Deta l Below), or following statement: "Miami -Dade County Product Control Approved ". LRT LAMOTI BARREL CONCRETE TILE LABEL (LOCATED ON UNDERSIDE OF TILE) NOA No.:06- 1214.07 Expiration Date: 03/14/12 Approval Date: 06 /28/07 Page 3 of 4 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall he itccompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required b:, Building Official or Applicable buildign code in order to properly evaluate the in: tallation of this system. PROFILE DRAWING 8.75" 2" 1 0 1 1 1 1 1 1 1 1 \\_BONDINGY I LOCKS 1 1 1 1 1 1 1 1 18" 8.75" LAMOT1 ROOF TILE "BARREL CONCRETE TILE" END OF THIS ACCEPTANCE NOA No.:06-1214.07 Expiration Date: 03/14/12 Approval Date: 06/28/07 Page 4 of 4