Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-13-1071
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 192608 Permit Number: MC -5 -13 -1071 Scheduled Inspection Date: June 05, 2013 Inspector: Perez, JanPierre Owner: Job Address: 47 NE 91 Street Miami Shores, FL Project: <NONE> Contractor: COMFORT TECH AIR CONDITIONING INC Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: A/C Replacement Phone Number Parcel Number 1132060130110 Phone: (305)969 -1203 Building Department Comments REPLACE 4 TON AC SYSTEM Infractio Passed Comments INSPECTOR COMMENTS False 0, 5 \:) Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. June 05, 2013 For Inspections please call: (305)762 -4949 Page 28 of 47 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 P Permit Type: MECHANICAL OWNER: Name (Fee Simple Titleholder): dA!1' /7 1/f7 / Phone#: 96Y' 0 7' 6f37 Permit No. MC,1 1 C511 Master Permit No. Address: / OA , o b 4 kid !ll e 2 City: `i aft A State: Zip: 33o Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: Li7 N'e gfir S'afe City: Miami Shores County: Miami Dade Zip: 9 x/'3 Folio/Parcel #: Is the Building Historically Designated: Yes NO X Flood Zone: CONTRACTOR: Company Name: &Atka r � ��� Phone#: � 9 9- / 0 3 Address: /31/7 /tX /0 7 Me,- — 6 i City: 2 , 601 State: P Zip: 330/8 Qualifier Name: 4 Y/ & C #1,� �E Z Phone#: 3D'.) 3» »132 State Certification or Registration #: Ne 057632 9' Certificate of Competency #: _ Contact Phone#: 31/-x3/- 1�3 Z Email Address: /7 g & :buffo:- :afro z , am DESIGNER: Architect/Engineer: Phone*: Value of Work for this Permit: $ /o t . Square/Linear Footage of Work: Type of Work: °Address °Alteration ONewtepair/Replace °Demolition Description of Work: /l C. 4 / 'l/(° Sr .i **** * * * * * * * * * * * * * * * * * * * * * * * * * * *** ** e* * * * * * **** *mix * *e *s * ***A4 *. * * ** * **** * ** *qtr *** CO /CC $ Bond $ Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ DBPR $ Technology Fee $ TOTAL FEE NOW DUE $ 2 • / Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FI.F,CTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S A} F'Il)AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will no 'b' approved ' a reinspection fee will be charged. Signature _; L / Signature Owner or Agent Contrac . r The foregoing instrument was acknowledged before me this 19441 The foregoing instrument was acknowledged before me is o�Ai—`� day of H'9 , 20 /3 , by 'i`1N t� i4, V (i C �� , day of M4 20 /3 , by �4 9 Xf&. kA4 4 7 who is personal! known to me or who has produced who is personally known tom r who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Print: te.�CM- Mato 4."4."e`'• JANICE AIMEE MATOS My Commission Expires: ° ;o: `� MY COMMISSION #FF011193 Q.II ;?eao?.'• EXPIRES April 23, 2017 APPROVED BY ,.z (Revised 07 /10/07)(Revised 06/l0/2009XRevised 3/15/09) Sign. Print' My Commission E Comm# EE193615 Expires 4/29/2016 ****************** * * * * * * * * * * * * * **** * * * * * * * * * * * * ** Plans Examiner Zoning Structural Review Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): / City: Miami Shores Village County: Miami Dade Zip Code: 3,3/38 ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES 0 NO 0 CalCS ARHI Sheet Attached: YES/0 NO 0 Contract �pttached: YES UNIT BEING REPLACED DATA NEW UNIT i MANUFACTURER 4.1.4.4 ,4 AHU or PKG. UNIT MODEL # R 1., /44PZ fPA COND. UNIT MODEL # _A /3.9_74 4a A / KW HEAT /0 AV' NOM TONS 4 to r) AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHUZto CU Z,tQPKG PKG UNIT / / PKG UNIT / / EERISEER /' 00 YES NO REPLACING DUCTS YES 000 . YES NO REPLACING THERMOSTAT NO YES NO NEW 4 °CONCRETE SLAB (rEJ2 NO YES NO NEW ROOF STAND YES YES NO NEW RETURN PLENUM BOX YES g0)1> 1. Minimum Circuit Ampacity (Wire Size): 6 2. Maximum Overcurrent Protection (Fuse/Breaker Size): ‘,0 4, Ip' 3. Voltage of Circuit (208/240/480): 2 7 0 4. Size Disconnecting Means* Teed Contractor's Company Name: &2/4 " i ∎ "/ , XIe Phone: 3a -169- /X 3 State Certificate or Registration N. C,e 05'32 V Certificate of Competency N. Signature Date: 5-) —20/3 Cf42/P" 13117 NW 107th Ave,Bay6 Hialeah Gardens, FL 33018 _wow- Tel: (305) 231 -9832 Fax: (305) 826 -9656 Comfort Tech Air Conditioning Residential & Commercial Proposal • State Certified Contractor • 24 Hr. Emergency Service • Licensed & Insured CAC057324 • CSBE Certified: #554 • DBE Certified: #3882 Page No.: 1 of 2 Page(s) PROPOSAL SUBMITTED TO: Invitation Homes Att. Alberto Sigarroa PHONE : FAX : DATE 03/13/13 ADDRESS Project Name: CITY, STATE AND ZIP CODE JOB LOCATION 47 NE 91st Street, Miami, FL. Scope of Work: • Remove and dispose the existing AC Unit. • Provide new 4Ton Split System. Not included: • Refrigerant lines. (existing). • Electrical work for the (3) new Exhaust Fans. We propose hereby to furnish material and labor — complete in accordance with the above specifications, for the sum of: Seven Thousand Six Hundred Dollars $ 7, 600.00 Authorized Signature: NOTE: This proposal may be withdrawn by Maykel Hernandez, President us if not accepted within 30 days. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Signature Date Signature Date Des ig nStar Load Calculation Results are intended for use with Rheem heating and cooling systems Customer Information oet Addrw SS. atitude, Longitude 25.7791 °, - 80.1978° 1-louse Square Footage: 1935 Name: Phone: Email: House Information HR Number er of resider) Ceiling height Wall U value I R -value Floor U -value I R -value ing U -value I R -value Window U -value \ indow SHGF Moisture grains yet loss "/0 Duct gain % Cooling infiltraction (ACH) .75 0.5 0.85 58 Heating infiltration (ACH) ventilation Summer ventilation 10 0'. 6 0.8 Desi. n Conditions Moi �r Indoor indoor temperature ( °F) Heating Cooling Design temperature difference( °F) 20 15 Heati I'1 Loads Infiltration Efficiency Los 4751 25.2 1714 9.1 Fol Heating Loads 12.850 STI.11hr System Efficiency Loss Floor Ceiling Wall Infiltration Windows 21743 4 Latent infiltration 6388 13.6 System Efficiency Gain 3878 8.3 Internal 3290 7 Sensible People Load 460 1 Latent People Load 460 1 Total: 46866 Sensible Load atent load 6848 SHR 0.85 Capacity at .75 SHR 4.45 Tons Cooling Loads 46;B66 BTU /hr Sensible People Load Latent People Load I Sensible Infiltration s ' Wall Internal Windows a System Efficiency Ceiling Latent Infiltration AED Graph 30000 - 20000 0 10000 --------- 8am 9am loam clam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm Hourly Loads — Average Ea ui. ment selection System equipment selection Glass (E) Glass (S) Glass (N) Glass (W) ill; be made using the following derived values. 140 sq. ft. 40 sq. ft. 40 sq. ft. 98 sq. ft. Summer Outdoor 90 °F Summer Wet Bulb Summer Indoor 77 °F Summer Design Grains Winter Outdoor Pinter Indoor Sensible Cooling Latent Cooling Required Cooling Airflow 50° 50°F 70 °F 40,018 Btuh 6,848 Btuh 1,819 CFM Sensible Heating 18,850 Btuh Required Heating Airflow 245 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree Load Calculator HOUSE INFORMATION What direction of the house has the most glass? Click the corresponding arrow next to the photo. Adjust square footage of window area on this home. Adjust square footage of window area: % Shading E 140 N 140 S 14F —W 198 p0 HOUSE INFORMATION What is the conditioned square footage of your house ?: Square feet: 11935 When was your house built? Before 1990 I 1990 - 2000 After 2000 How do you want insulation values displayed? R 1 U Winter Electricity Rate Summer Electricity Rate Natural Gas Rate ............................. ............................... Propane Rate Oil Rate Summer indoor design temperature Summer outdoor design temperature 0. 0.1 1.2 2.5 2.3 Page 1 of 3 HOUSE LOADS Cooling Load: 146,866 Heating Load: 18,850 s ADEQUATE EXPOSURE DIVERSITY (AED) 24,000 18,000 12,000 6,000 0 8am 10am Opm 2pm 4pm 6pm 8pm 9am 11am 1pm 3pm 5pm 7pm a Hourly Loads r Average f LOADS GRAPH 60,000 30,000 15.000 0 .. ..... ,., .. Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec HEATING a COOLING '" HEATING operating • COOLING operating Windows Cooling Loads 46,866 btu ht �Sensible People Load ("/'�� -- Latent People Lo Sensible In1 Wall — Inten Latent Infiltration Sy Ceiling http: / /yourvirtualhvac.com/contractor /loads / ?user hash= 4d7Oacebeb47937d0b862058ac332 ... 5/3/2013 Load Calculator Winter indoor design temperature Winter outdoor design temperature SHR Number of Residents Average Ceiling Height Wall R -Value .............................. ............................... Floor R -Value Ceiling R -Value Window U -Value Single Pane = 1 Double Pane = .5 Triple Pane = .3 Window SHGF Clear = 1 -.85 Low -E = .6 -.4 Grains of moisture difference Duct Loss Wo Duct Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cooling Infiltration Rate (ACH) Heating Infiltration Rate (ACH) Winter Ventilation ...................................................... ............................... Summer Ventilation 70 50 ! ............ ...........:................... 5 ............ ............................... l 11.11 a .......................... ............................... 5.00 18.87 as ...................... 0.5 0.85 58 a 0 FLOORS CUSTOMER INFORMATION Fill in the customer information Floor Heating Loads 18,850 btuihr Page 2 of 3 System Efficiency Loss Ceiling Infiltration Windows http: / /yourvirtualhvac.com/contractor /loads / ?user hash= 4d70acebeb47937d0b862058ac332 ... 5/3/2013 Load Calculator Name Email Phone Invitation Homes Get Proposal Page 3 of 3 http:/ /yourvirtualhvac.com/contractor /loads / ?user hash= 4d7Oacebeb47937d0b862058ac332 ... 5/3/2013 FORM NO. A11 -204 REV. 1 Supersedes Form No. A11 -204 Featuring Industry Standard R -410A Refrigerant 410A 13A *N SERIES ISO 9001:2008 c LISTED US 13 SEER CONDENSING UNITS Features ■ Painted louvered steel cabinet • Easily accessible control box • Condenser coils constructed with copper tubing and enhanced aluminum fins ■ Grille /Motor mount for quiet fan operation • Filter Drier (shipped — not installed) Applications Outdoor condensing unit designed for ground level or rooftop installations. These units offer comfort and depend- ability for single, multi - family and light commercial applications. Accessories • Low Pressure Control (R)(AC -A07) • High Pressure Control (RXAB -A07) • Low Ambient Control (RXAD -A08) • Compressor Time Delay Control • Crankcase Heater ■ Sound Enclosure ENERGY STAR (IN CERTAIN MATCHED SYSTEMS) ru . d CERTIFIED,. Unn.:.ar Sm,14,s ENER(3UIDE SxxmfEnvnEf(4 npRriejSEER) i)erformance Data @ AHRI Standard Conditions - Cooling (con't.) Model Numbers 80 °F [26.5 °C1 DB/67 °F [19.5 °C1 WB Indoor Air 95 °F [35 °C] DB Outdoor Air Sound Rating dB Indoor CFM [l./s1 Outdoor Unit 13A *N Indoor Coil and /or Air Handler Total Capacity BTU/H [kW1 Net Sensible BTU/H [kW1 Net Latent BTU/H [kW] EER SEER cY, 8/29/11 48' (13AJN 13ACN, 13ADN, 13AYN) RCFL- H *4824(RGRM -12 ?RAJ ?) 47.000 113.81 32.800 [9.6] 14.200 [4.2] 11.00 13.00 73 1,425 [672] RCFL- H *4824(RGTM -07 ?RBG ?) 47,000 [13.8] 33,400 [9.8] 13,600 [4.0] 11.00 13.00 73 1,475 [6961 RCFL- H *4824(RGTM -09 ?ZAJ ?) 46,500 [13.6] 32,400 [9.5] 14.100 [4.1] 11.00 13.00 73 1,400 [661] RCFL- H *4824(RGTM -10 ?RBJ ?) 47,000 [13.8] 32,800 [9.6] 14,200 [4.2] 11.00 13.00 73 1,425 [6721 RCFL- H *4824(R0LA- 070E04) 47,000 [13.8] 32,400 [9.5] 14,600 [4.3] 11.00 13.00 73 1,375 [649] RCFL- H *4824(R0LA- 115E05) 47,000 [13.8] 32,600 [9.6] 14,400 [4.2] 11.00 13.00 73 1,400 [661] RCFL -H *4824 +RXMD -004 47,500 [13.9] 34,400 [10.1] 13,100 [3.8] 10.50 13.00 73 1,575 [743] RBHP- 24(RCHL -48A1) 46,500 [13.6] 31,950 [9.4] 14,550 [4.3] 11.00 13.50 73 1 ,400 [661] RCQD- 4821(RGPE -07 ?BRQ ?) 48,500 [14.2] 35,950 [10.5] 12,550 [3.7] 11.50 13.00 73 1,400 [661] RCQD- 4821(R3PE -10 ?BRM ?) 49,000 [14.4] 37,650 [11.0] 11,350 [3.3] 11.50 13.00 73 1,550 [731] RCQD- 4821(RGPT -07 ?BRQ ?) 49,500 [14.5] 38,100 [11.2] 11,400 [3.3] 11.50 13.50 73 1,550 [731] RCQD- 4821(RGPT -10 ?BRM ?) 48,500 [14.2] 36,100 [10.6] 12,400 [3.6] 11.50 13.50 73 1,425 [672] RCQD- 4821(ROLA- 070E04) 48,000 [14.1] 35,300 [10.3] 12,700 [3.7] 11.50 13.00 73 1,375 [649] RCQD- 4821(ROLA- 115E05) 48,000 [14.1] 35,450 [10.4] 12,550 [3.7] 11.50 13.00 73 1,400 [661] RCQD- 4821 +RXMD -004 48,500 [14.2] 37,250 [10.9] 11,250 [3.3] 10.50 13.00 73 1,500 [708] RCQD- 4824(RGFE -12 ?RCM ?) 48,500 [14.2] 36,300 [10.6] 12,200 [3.6] 11.50 13.00 73 1,450 [684] RCQD- 4824(R6FG -12 ?RCM ?) 48,500 [14.2] 36,300 [10.6] 12,200 [3.6] 11.50 13.00 73 1,450 [684] RCQD- 4824(RGJF- 09 ?ZCM ?) 48,000 [14.1] 35,450 [10.4] 12,550 [3.7] 11.50 13.00 73 1,400 [661] RCQD- 4824(RGJF -12 ?RCM ?) 48,500 [14.2] 35,750 [10.5] 12,750 [3.7] 11.50 13.50 73 1,375 [649] RCQD- 4824(RGPE -07 ?BRQ ?) 48,500 [14.2] 35,900 [10.5] 12,600 [3.7] 11.50 13.50 73 1,400 [661] RCQD- 4824(RGPE -10 ?BRM ?) 48,500 [14.2] 35,900 [10.5] 12,600 [3.7] 11.50 13.50 73 1,400 [661] RCQD- 4824(RGPE -12 ?ARM ?) 49,000 [14.4] 37,250 [10.9] 11,750 [3.4] 11.50 13.50 73 1,525 [720] RCQD- 4824(RGPT -07 ?BRQ ?) 49,500 [14.5] 38,100 [11.2] 11,400 [3.3] 11.50 13.50 73 1,550 [731] RCQD- 4824(RGPT -10 ?BRM ?) 48,500 [14.2] 36,250 [10.6] 12,250 [3.6] 11.50 13.50 73 1,450 [684] R000- 4824(RGPT -12 ?ARM ?) 48,500 [14.2] 35,850 [10.5] 12,650 [3.7] 11.50 13.50 73 1,400 [661] RCQD- 4824(RGRM -12 ?RAJ ?) 48,500 [14.2] 36,150 [10.6] 12,350 [3.6] 11.50 13.00 73 1,425 [672] RCQD- 4824(RGTM -07 ?RBG ?) 48,500 [14.2] 36,500 [10.7] 12,000 [3.5] 11.50 13.00 73 1,475 [696] RCQD- 4824(RGTM -09 ?ZAJ ?) 48,000 [14.1] 35,450 [10.4] 12,550 [3.7] 11.50 13.00 73 1,400 [661] RCQD- 4824(RGTM -10 ?RBJ ?) 48,500 [14.2] 36,100 [10.6] 12,400 [3.6] 11.50 13.00 73 1,425 [672] RCQD- 4824(ROLA- 070E04) 48,000 [14.1] 35,250 [10.3] 12,750 [3.7] 11.50 13.00 73 1,375 [649] RCQ0- 4824(R0LA- 115E05) 48,500 [14.2] 35,950 [10.5] 12,550 [3.7] 11.50 13.00 73 1,400 [661] RCQD- 4824 +RXMD -004 48,500 [14.2] 37,250 [10.9] 11,250 [3.3] 10.50 13.00 73 1,500 [708] RHKL- HM4821(RCSL -H *4821) 47,000 [13.8] 32,800 [9.6] 14,200 [4.2] 11.50 13.50 73 1,400 [661] RHLL- HM4821(RCSL -H"4821) 46,500 [13.6] 32,150 [9.4] 14,350 [4.2] 11.50 14.00 73 1,450 [684] RHSL- HM4821(RCSL -H *4821) 46,000 [13.5] 33,300 [9.8] 12,700 [3.7] 10.50 13.00 73 1,550 [731] RHKL- HM4824(RCSL -H *4824) 48,500 [14.2] 35,400 [10.4] 13,100 [3.8] 11.50 13.50 73 1,625 [767] RHKL- HM6024(RCSL -H *4824) 48,000 [14.1] 34,800 [10.2] 13,200 [3.9] 11.50 14.00 73 1,600 [755] RHLL- HM4824(RCSL -H *4824) 48,500 114.2] 35,400 [10.4] 13,100 [3.8] 11.50 14.00 73 1,625 [767] RHSL- HM4824(RCSL -H"4824) 46,000 [13.5] 33,300 [9.8] 12,700 [3.7] 10.50 13.00 73 1,550 [731] 60 (13AJN, 13ACN, 13ADN, 13AYN) I RCFL -H *6024 +RXMD -004 O 56,500 [16.6] 38,950 [11.4] 17,550 [5.1] 10.50 13.00 74 1,525 [720] RCFL- A *6024(RGGE -12 ?RCM ?) 57,000 [16.7] 40,000 [11.7] 17,000 [5.0] 10.50 13.00 74 1,575 [743] RCFL- A *6024(RGLE -07 ?BRQ ?) 57,000 [16.7] 40,000 [11.7] 17,000 [5.0] 10.50 13.00 74 1,600 [755] RCFL- A *6024(RGLE -10 ?BRM ?) 57,500 [16.8] 40,000 [11.7] 17,500 [5.1] 10.50 13.00 74 1,600 [755] RCFL- A *6024(RGLE -12 ?ARM ?) 57,500 [16.8] 40,000 [11.7] 17,500 [5.1] 10.50 13.00 74 1,600 [755] RCFL- A *6024(RGLR -07 ?BRQ ?) 57,500 [16.8] 40,500 [11.9] 17,000 [5.0] 10.50 13.00 74 1,625 [767] RCFL- A *6024(RGLR -10 ?BRM ?) 57,000 [16.7] 40,000 [11.7] 17,000 [5.0] 10.50 13.00 74 1,575 [743] RCFL- A *6024(RGLR -12 ?ARM? ) 57,500 [16.8] [ ] 40,000 [11.7] [ 17,500 [5.1] 10.50 13.00 74 1,600 755 [ 1 RCFL- A *6024(RGLT -12 ?ARM ?) 57,500 [16.8] 41,500 [12.2] 16,000 [4.7] 10.50 13.00 74 1,700 [802] RCFL- A *6024(RGPE -07 ?BRQ ?) 57,000 [16.7] 40,000 [11.7] 17,000 [5.0] 10.50 13.00 74 1,600 [755] RCFL- A *6024(RGPE -10 ?BRM ?) 57,500 [16.8] 40,500 [11.9] 17,000 [5.0] 10.50 13.00 74 1,625 [767] RCFL- A *6024(R3PE -12 ?ARM ?) 57,500 [16.8] 40,500 111.9] 17,000 [5.0] 10.50 13.00 74 1,625 [767] RCFL- A *6024(RGPT -10 ?BRM ?) 57,500 [16.8] 41,500 [12.2] 16,000 [4.7] 10.50 13.00 74 1,700 [802] RCFL- A *6024(RGPT -12 ?ARM ?) 57,500 [16.8] 41,500 [12.2] 16,000 [4.7] 10.50 13.00 74 1,700 [802] ) Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating 17 Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. Rheem Heating, Cooling and Water Heating P.O. Box 17010, Fort Smith, AR 72917 in keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." PRINTED IN U.S.A. 9 -11 DC FORM NO. A11 -204 REV. 1 Supersedes Form No. A11 -204 AHRI Certified Reference Number: 4526116 Date: 5/3/2013 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 13AJN48 Indoor Unit Model Number: RHSL- HM4821 +RCSL -H *4821 Manufacturer: RHEEM MANUFACTURING COMPANY Trade /Brand name: RHEEM 13AJN SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 46000 EER Rating (Cooling): 10.50 SEER Rating (Cooking): 13.00 * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at . TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at click on " link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130120684458248140